1
|
Tang Y, Qi L, Xu L, Lin L, Cai J, Shen W, Liu Y, Li M. Atrial giant cell myocarditis with preserved left ventricular function: a case report and literature review. J Cardiothorac Surg 2023; 18:232. [PMID: 37452361 PMCID: PMC10347761 DOI: 10.1186/s13019-023-02316-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023] Open
Abstract
Giant cell myocarditis (GCM) is a rare and fatal inflammatory disorder induced by T-lymphocytes, typically affecting young adults. Generally, this disease presents with a rapidly progressive course and a very poor prognosis. In recent years, atrial GCM (aGCM) has been recognized as a clinicopathological entity distinct from classical GCM. As described by retrievable case reports, although its histopathological manifestations are highly similar to those of classical GCM, this entity is characterized by preserved left ventricular function and atrial arrhythmias, without ventricular arrhythmias. aGCM tends to show benign disease progression with a better clinical prognosis compared with the rapid course and poor prognosis of vGCM. We report a patient with aGCM with a history of renal abscess whose persistent myocardial injury considered to be associated with a history of renal abscess. Infection could be a potential trigger for the development of aGCM in this patient. An extensive literature review was also performed and the following three aspects were summarized: (1) Epidemiology and histopathological characteristics of aGCM; (2) The role of imaging in the evaluation of aGCM; (3) Diagnostic points and therapeutic decisions in aGCM.
Collapse
Affiliation(s)
- Yilin Tang
- Department of Radiology, Huadong Hospital Affiliated to Fudan University, No. 221 West Yanan Road, Shanghai, 200040, China
| | - Lin Qi
- Department of Radiology, Huadong Hospital Affiliated to Fudan University, No. 221 West Yanan Road, Shanghai, 200040, China.
| | - Ling Xu
- Department of Cardiovascular Surgery, Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Lei Lin
- Department of Cardiovascular Surgery, Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Junfeng Cai
- Department of Cardiovascular Surgery, Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Wei Shen
- Department of Cardiovascular Surgery, Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Yang Liu
- Department of Cardiovascular Surgery, Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Ming Li
- Department of Radiology, Huadong Hospital Affiliated to Fudan University, No. 221 West Yanan Road, Shanghai, 200040, China.
| |
Collapse
|
2
|
Świerżyńska E, Oręziak A, Główczyńska R, Rossillo A, Grabowski M, Szumowski Ł, Caprioglio F, Sterliński M. Rate-Responsive Cardiac Pacing: Technological Solutions and Their Applications. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23031427. [PMID: 36772467 PMCID: PMC9920425 DOI: 10.3390/s23031427] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/18/2023] [Accepted: 01/20/2023] [Indexed: 05/12/2023]
Abstract
Modern cardiac pacemakers are equipped with a function that allows the heart rate to adapt to the current needs of the patient in situations of increased demand related to exercise and stress ("rate-response" function). This function may be based on a variety of mechanisms, such as a built-in accelerometer responding to increased chest movement or algorithms sensing metabolic demand for oxygen, analysis of intrathoracic impedance, and analysis of the heart rhythm (Q-T interval). The latest technologies in the field of rate-response functionality relate to the use of an accelerometer in leadless endocavitary pacemakers; in these devices, the accelerometer enables mapping of the mechanical wave of the heart's work cycle, enabling the pacemaker to correctly sense native impulses and stimulate the ventricles in synchrony with the cycles of atria and heart valves. Another modern system for synchronizing pacing rate with the patient's real-time needs requires a closed-loop system that continuously monitors changes in the dynamics of heart contractions. This article discusses the technical details of various solutions for detecting and responding to situations related to increased oxygen demand (e.g., exercise or stress) in implantable pacemakers, and reviews the results of clinical trials regarding the use of these algorithms.
Collapse
Affiliation(s)
- Ewa Świerżyńska
- Department of Arrhythmia, The Cardinal Stefan Wyszynski National Institute of Cardiology, 04-628 Warsaw, Poland
- 1st Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland
- Correspondence:
| | - Artur Oręziak
- Department of Arrhythmia, The Cardinal Stefan Wyszynski National Institute of Cardiology, 04-628 Warsaw, Poland
| | - Renata Główczyńska
- 1st Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland
| | - Antonio Rossillo
- Department of Cardiology, San Bortolo Hospital, 36100 Vicenza, Italy
| | - Marcin Grabowski
- 1st Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland
| | - Łukasz Szumowski
- Department of Arrhythmia, The Cardinal Stefan Wyszynski National Institute of Cardiology, 04-628 Warsaw, Poland
| | | | - Maciej Sterliński
- Department of Arrhythmia, The Cardinal Stefan Wyszynski National Institute of Cardiology, 04-628 Warsaw, Poland
| |
Collapse
|
3
|
Teixeira RA, Fagundes AA, Baggio Junior JM, Oliveira JCD, Medeiros PDTJ, Valdigem BP, Teno LAC, Silva RT, Melo CSD, Elias Neto J, Moraes Júnior AV, Pedrosa AAA, Porto FM, Brito Júnior HLD, Souza TGSE, Mateos JCP, Moraes LGBD, Forno ARJD, D'Avila ALB, Cavaco DADM, Kuniyoshi RR, Pimentel M, Camanho LEM, Saad EB, Zimerman LI, Oliveira EB, Scanavacca MI, Martinelli Filho M, Lima CEBD, Peixoto GDL, Darrieux FCDC, Duarte JDOP, Galvão Filho SDS, Costa ERB, Mateo EIP, Melo SLD, Rodrigues TDR, Rocha EA, Hachul DT, Lorga Filho AM, Nishioka SAD, Gadelha EB, Costa R, Andrade VSD, Torres GG, Oliveira Neto NRD, Lucchese FA, Murad H, Wanderley Neto J, Brofman PRS, Almeida RMS, Leal JCF. Brazilian Guidelines for Cardiac Implantable Electronic Devices - 2023. Arq Bras Cardiol 2023; 120:e20220892. [PMID: 36700596 PMCID: PMC10389103 DOI: 10.36660/abc.20220892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Affiliation(s)
| | | | | | | | | | | | | | - Rodrigo Tavares Silva
- Universidade de Franca (UNIFRAN), Franca, SP - Brasil
- Centro Universitário Municipal de Franca (Uni-FACEF), Franca, SP - Brasil
| | | | - Jorge Elias Neto
- Universidade Federal do Espírito Santo (UFES), Vitória, ES - Brasil
| | - Antonio Vitor Moraes Júnior
- Santa Casa de Ribeirão Preto, Ribeirão Preto, SP - Brasil
- Unimed de Ribeirão Preto, Ribeirão Preto, SP - Brasil
| | - Anisio Alexandre Andrade Pedrosa
- Instituto do Coração (Incor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP - Brasil
| | | | | | | | | | - Luis Gustavo Belo de Moraes
- Hospital Universitário Clementino Fraga Filho, Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ - Brasil
| | | | | | | | | | - Mauricio Pimentel
- Hospital de Clínicas de Porto Alegre, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS - Brasil
| | | | - Eduardo Benchimol Saad
- Hospital Pró-Cardíaco, Rio de Janeiro, RJ - Brasil
- Hospital Samaritano, Rio de Janeiro, RJ - Brasil
| | | | | | - Mauricio Ibrahim Scanavacca
- Instituto do Coração (Incor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP - Brasil
| | - Martino Martinelli Filho
- Instituto do Coração (Incor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP - Brasil
| | - Carlos Eduardo Batista de Lima
- Hospital Universitário da Universidade Federal do Piauí (UFPI), Teresina, PI - Brasil
- Empresa Brasileira de Serviços Hospitalares (EBSERH), Brasília, DF - Brasil
| | | | - Francisco Carlos da Costa Darrieux
- Instituto do Coração (Incor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP - Brasil
| | | | | | | | | | - Sissy Lara De Melo
- Instituto do Coração (Incor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP - Brasil
| | | | - Eduardo Arrais Rocha
- Hospital Universitário Walter Cantídio, Universidade Federal do Ceará (UFC), Fortaleza, CE - Brasil
| | - Denise Tessariol Hachul
- Instituto do Coração (Incor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP - Brasil
| | | | - Silvana Angelina D'Orio Nishioka
- Instituto do Coração (Incor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP - Brasil
| | | | - Roberto Costa
- Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP - Brasil
| | | | - Gustavo Gomes Torres
- Hospital Universitário Onofre Lopes, Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN - Brasil
| | | | | | - Henrique Murad
- Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ - Brasil
| | | | | | - Rui M S Almeida
- Centro Universitário Fundação Assis Gurgacz, Cascavel, PR - Brasil
| | | |
Collapse
|
7
|
Gilliam FR, Giudici M, Benn A, Koplan B, Berg KJC, Kraus SM, Stolen KQ, Alvarez GE, Hopper DL, Wilkoff BL. Design and rationale of the assessment of proper physiologic response with rate adaptive pacing driven by minute ventilation or accelerometer (APPROPRIATE) trial. J Cardiovasc Transl Res 2010; 4:21-6. [PMID: 21104046 DOI: 10.1007/s12265-010-9228-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2010] [Accepted: 09/27/2010] [Indexed: 11/26/2022]
Abstract
Rate-adaptive sensors are designed to restore a physiologic heart rate response to activity, in particular for patients that have chronotropic incompetence (CI). Limited data exist comparing two primary types of sensors; an accelerometer (XL) sensor which detects activity or motion and a minute ventilation (MV) sensor, which detects the product of respiration rate and tidal volume. The APPROPRIATE study will evaluate the MV sensor compared with the XL sensor for superiority in improving functional capacity (peak VO(2)) in pacemaker patients that have CI. This study is a double-blind, randomized, two-arm trial that will enroll approximately 1,000 pacemaker patients. Patients will complete a 6-min walk test at the 2-week visit to screen for potential CI. Those projected to have CI will advance to a 1-month visit. At the 1-month visit, final determination of CI will be done by completing a peak exercise treadmill test while the pacemaker is programmed to DDDR with the device sensors set to passive. Patients failing to meet the study criteria for CI will not continue further in the trial. Patients that demonstrate CI will be randomized to program their rate-adaptive sensors to either MV or XL in a 1:1 ratio. The rate-adaptive sensor will be optimized for each patient using a short walk to determine the appropriate response factor. At a 2-month visit, patients will complete a CPX test with the rate-adaptive sensors in their randomized setting.
Collapse
Affiliation(s)
- F Roosevelt Gilliam
- Cardiology Associates of NE Arkansas, One Medical Plaza, 201 East Oak, Suite 101, Jonesboro, AR 72401, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Coman J, Freedman R, Koplan BA, Reeves R, Santucci P, Stolen KQ, Kraus SM, Meyer TE. A blended sensor restores chronotropic response more favorably than an accelerometer alone in pacemaker patients: the LIFE study results. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2009; 31:1433-42. [PMID: 18950301 DOI: 10.1111/j.1540-8159.2008.01207.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Adaptive rate sensors used in permanent pacemakers incorporate an accelerometer (XL) to increase heart rate with activity. Limited data exists regarding the relative benefit of a blended sensor (BS) (XL and minute ventilation) versus XL alone in restoring chronotropic response (CR) in chronotropically incompetent (CI) patients. METHODS One thousand five hundred thirty-eight patients from the limiting chronotropic incompetence for pacemaker recipients (LIFE) study were implanted with a pacemaker and 1,256 patients had data collected at 1 month. Patients performed a treadmill test 1-month postimplant while programmed in nonrate responsive mode (DDD-60) to determine CI. Only patients who completed at least three exercise stages and achieved a peak perceived exertion >or=16 were included in the analyses. The metabolic chronotropic relationship (MCR) slope was used to evaluate CR in 547 patients. Patients were randomized to XL or BS with a conservative fixed rate response factor (XL = 8, MV = 4). CI patients performed a follow-up 6-month treadmill test. RESULTS CI prevalence in this patient population (n = 547) was 34%. No differences in baseline characteristics existed between groups. Although both groups showed significant within-group improvements in MCR slope from 1 to 6 months (both P < 0.001), the BS group had a significantly higher MCR slope at 6 months compared to the XL group (P = 0.011). Improvement in quality of life (QOL) did not differ between groups. CONCLUSIONS In this general pacemaker population with CI, a BS programmed empirically restores CR more favorably than an XL sensor programmed nominally. Further studies are needed to determine if individual sensor optimization would lead to improvement in functional capacity, higher MCR slopes, and QOL.
Collapse
Affiliation(s)
- James Coman
- Hillcrest Medical Center, Tulsa, Oklahoma, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|