Mei DA, Imberti JF, Vitolo M, Bonini N, Gerra L, Romiti GF, Proietti M, Lip GYH, Boriani G. Single-lead VDD pacing: a literature review on short-term and long-term performance. Expert Rev Med Devices 2023; 20:187-197. [PMID: 36755414 DOI: 10.1080/17434440.2023.2178901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2023]
Abstract
INTRODUCTION VDD pacing system was introduced more than 30 years ago. Its use is considered by the 2021 European Society of Cardiology guidelines on cardiac pacing as a potential alternative to dual chambers system for patients with atrioventricular block and normal sinus node function. AREAS COVERED In this article, we performed a narrative review of current literature in order to identify the strengths and weaknesses of this pacing system. VDD system allows the maintenance of AV synchronous pacing and its hemodynamic advantages. Some disadvantages may be related to the non-negligible incidence of atrial undersensing and the possible subsequent need for upgrade to DDD system. On the other hand, shorter implantation time and lower complications rate may be advantages. EXPERT OPINION In the modern pacing era, VDD pacing system struggles to find its own space. However, it may still be considered as a valuable alternative to a dual-chamber pacemaker for selected patients, in specific clinical scenarios.
Collapse
Affiliation(s)
- Davide Antonio Mei
- Cardiology Division Department of Biomedical Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy.,Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK
| | - Jacopo Francesco Imberti
- Cardiology Division Department of Biomedical Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy.,Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Marco Vitolo
- Cardiology Division Department of Biomedical Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy.,Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Niccolò Bonini
- Cardiology Division Department of Biomedical Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy.,Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK.,Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Luigi Gerra
- Cardiology Division Department of Biomedical Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Giulio Francesco Romiti
- Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK.,Department of Translational and Precision Medicine, Sapienza - University of Rome, Rome, Italy
| | - Marco Proietti
- Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy.,Geriatric Unit, IRCCS Istituti Clinici Scientifici Maugeri, Milan, Italy
| | - Gregory Y H Lip
- Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK.,Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Giuseppe Boriani
- Cardiology Division Department of Biomedical Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| |
Collapse
|
2
|
Campos NLKLD, Andrade RRD, Fellicio ML, Martins AS, Garzesi AM, Garcia LR, Takeda TB. Comparative Study of Electrical Stimulation of the Heart with VDD and DDD Pacemakers as to the Evolution to Atrial Fibrillation. Braz J Cardiovasc Surg 2017; 32:347-353. [PMID: 29211212 PMCID: PMC5701096 DOI: 10.21470/1678-9741-2017-0505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Accepted: 04/10/2017] [Indexed: 11/09/2022] Open
Abstract
Introduction The pacemaker implantation VDD is considered simpler, faster, less expensive
and causes fewer complications compared to DDD. However, the VDD pacemaker
has not been widely used in many centers, perhaps for fear of dysfunction of
the sinus node and the reduction of atrial sensitivity by the pacemaker
during follow-up after implantation. Objective To compare patients with DDD and VDD pacemakers regarding the evolution of
chronic atrial fibrillation (AF) and length of stay outside this
postoperative arrhythmia. Methods It was included 158 patients with dual chamber pacemakers, 48 DDD and 110
VDD. Follow-up period: between January 1, 1999 and December 31, 2015. The
mean follow-up of patients with DDD was 5.35 years and the VDD, 4.74 years.
The percentage of each group (DDD and VDD) which evolved to AF during
follow-up was assessed. Also, it was made an actuarial study with the
respective curves indicating the time free from AF for each group. Patients
were classified according to the diagnosis that led to pacemaker
implantation and the degree of heart failure. Results The percentage of patients who developed AF was higher in DDD group (10.42%)
than in VDD group (6.36%), but without statistical significance. Patients
with DDD and VDD remained free of AF for similar period. Conclusion Considering the results, the VDD pacemaker continues to be a good option to
the DDD for routine use in cases properly indicated.
Collapse
|
5
|
Gillis AM, Russo AM, Ellenbogen KA, Swerdlow CD, Olshansky B, Al-Khatib SM, Beshai JF, McComb JM, Nielsen JC, Philpott JM, Shen WK. HRS/ACCF Expert Consensus Statement on Pacemaker Device and Mode Selection. J Am Coll Cardiol 2012; 60:682-703. [DOI: 10.1016/j.jacc.2012.06.011] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
6
|
Marchandise S, Scavee C, le Polain de Waroux JB, de Meester C, Vanoverschelde JL, Debbas N. Long-term follow-up of DDD and VDD pacing: a prospective non-randomized single-centre comparison of patients with symptomatic atrioventricular block. Europace 2011; 14:496-501. [DOI: 10.1093/europace/eur345] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
7
|
Blich M, Suleiman M, Shwiri TZ, Marai I, Boulos M, Amikam S. Long-term outcome of atrial synchronous mode pacing in patients with atrioventricular block using a single lead. Clin Cardiol 2010; 33:18-22. [PMID: 20063297 DOI: 10.1002/clc.20695] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Current guidelines suggest the use of atrial synchronous mode (VDD) pacemakers in patients with atrioventricular (AV) block and normal sinus node function. However VDD mode is being used much less than expected. The objectives of our study were to evaluate the efficacy of VDD pacing in long-term follow-up and to find risk factors for VDD loss. METHODS We retrospectively evaluated all patients with VDD pacemakers who were implanted in our center between 1995 and 2007. RESULTS During the study period, 123 consecutive patients with AV block (51% men, age 62 +/- 17.8 years) received a VDD pacemaker. Mean follow up duration was 4.5 +/- 3.2 years. At the last follow up visit, 21 patients (21.6%) lost their original VDD mode and were programmed to ventricular-based pacing (VVIR) (undersensing, 11; chronic AF, 7; SND, 3). In 28 patients, VDD mode was restored or maintained by increasing atrial sensitivity. No episodes of atrial oversensing were observed. In multivariate analysis history of paroxysmal AF (p = 0.007, odds ratio 36.6, 95% confidence interval 2.7-493.7) and p wave lower than 1 mv during the follow up (p = 0.021, odds ratio 7, 95% confidence interval 1.3-36.7), were found risk factors to VDD loss. CONCLUSIONS VDD pacing has good long-term performance. Absence of paroxysmal AF history predicts maintenance of VDD pacing mode. Taking into account that no atrial oversensing was observed, our recommendation is to increase atrial sensitivity when P wave amplitude declines to less than 1 mv.
Collapse
Affiliation(s)
- Miry Blich
- Rambam Health Care Campus, Pacing and Electrophysiology Unit, Bat Galim Halfa, Israel. M
| | | | | | | | | | | |