Schirdewan A, Herm J, Roser M, Landmesser U, Endres M, Koch L, Haeusler KG. Loop Recorder Detected High Rate of Atrial Fibrillation Recurrence after a Single Balloon- or Basket-Based Ablation of Paroxysmal Atrial Fibrillation: Results of the MACPAF Study.
Front Cardiovasc Med 2017;
4:4. [PMID:
28243592 PMCID:
PMC5303896 DOI:
10.3389/fcvm.2017.00004]
[Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 01/18/2017] [Indexed: 11/28/2022] Open
Abstract
Purpose
Pulmonary vein isolation (PVI) is an established approach to treat symptomatic non-permanent atrial fibrillation (AF). Detecting AF recurrence after PVI is important, if discontinuation of oral anticoagulation after ablation is considered.
Methods
Patients with symptomatic paroxysmal AF were enrolled in the prospective randomized mesh ablator vs. cryoballoon pulmonary vein (PV) ablation of symptomatic paroxysmal AF study, comparing efficacy and safety of the HD Mesh Ablator® (C.R. Bard, Lowell, MA, USA) and the Arctic Front® (Medtronic, Minneapolis, MN, USA) catheter. Rhythm status post-PVI was closely monitored for 1 year using the implantable loop recorder (ILR) Reveal XT® (Medtronic Minneapolis, MN, USA).
Results
The study was terminated after the first interim analysis due to the inability of the HD Mesh Ablator® to achieve the predefined primary study endpoint, an exit block of all PVs. After a 90-day blanking period, 23 (62.2%) out of 37 study patients (median 63.0 years; 41% females) had at least one episode of AF. AF recurrence was associated with AF episodes during the blanking period {hazard ratios (HR) 5.10 [95% confidence interval (CI) 1.21–21.4]; p = 0.038}, and a common left-sided PV ostium [HR 4.17 (95%CI 1.48–11.8); p = 0.039] but not with catheter type, age, gender, cardiovascular risk profile, or left atrial volume. There was a trend toward AF recurrence in patients without complete PVI of all PV (p = 0.095). Overall, 337 (59.4%) out of 566 ILR-detected episodes represented AF. Comparing patients with AF recurrence to those without, there was no difference in cognitive performance 6 months post-ablation.
Conclusion
Using an ILR, in more than 60% of all patients with paroxysmal AF, a recurrence of AF was detected within 12 months after ablation. In patients with a common PV ostium, the first generation balloon-based catheter is obviously less effective.
Clinical trials
http://Clinicaltrials.gov NCT01061931.
Collapse