Liu Y, Mack JO, Shojaee M, Shaver A, George A, Clarke W, Patel N, Arroyo-Currás N. Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays. ACS Sens 2024; 9:228-235. [PMID: 38110361 PMCID: PMC10826698 DOI: 10.1021/acssensors.3c01868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 11/27/2023] [Accepted: 12/05/2023] [Indexed: 12/20/2023]
Abstract
The practice of monitoring therapeutic drug concentrations in patient biofluids can significantly improve clinical outcomes while simultaneously minimizing adverse side effects. A model example of this practice is vancomycin dosing in intensive care units. If dosed correctly, vancomycin can effectively treat methicillin-resistant streptococcus aureus (MRSA) infections. However, it can also induce nephrotoxicity or fail to kill the bacteria if dosed too high or too low, respectively. Although undeniably important to achieve effectiveness, therapeutic drug monitoring remains inconvenient in practice due primarily to the lengthy process of sample collection, transport to a centralized facility, and analysis using costly instrumentation. Adding to this workflow is the possibility of backlogs at centralized clinical laboratories, which is not uncommon and may result in additional delays between biofluid sampling and concentration measurement, which can negatively affect clinical outcomes. Here, we explore the possibility of using point-of-care electrochemical aptamer-based (E-AB) sensors to minimize the time delay between biofluid sampling and drug measurement. Specifically, we conducted a clinical agreement study comparing the measurement outcomes of E-AB sensors to the benchmark automated competitive immunoassays for vancomycin monitoring in serum. Our results demonstrate that E-ABs are selective for free vancomycin─the active form of the drug, over total vancomycin. In contrast, competitive immunoassays measure total vancomycin, including both protein-bound and free drug. Accounting for these differences in a pilot study consisting of 85 clinical samples, we demonstrate that the E-AB vancomycin measurement achieved a 95% positive correlation rate with the benchmark immunoassays. Therefore, we conclude that E-AB sensors could provide clinically useful stratification of patient samples at trough sampling to guide effective vancomycin dose recommendations.
Collapse
Affiliation(s)
- Yu Liu
- ZiO
Health Ltd., The Tower,
St George Wharf, London SW82BW, U.K.
| | - John O. Mack
- Biochemistry,
Cellular and Molecular Biology Program, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
| | - Maryam Shojaee
- ZiO
Health Ltd., The Tower,
St George Wharf, London SW82BW, U.K.
| | - Alexander Shaver
- Department
of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
| | - Ankitha George
- ZiO
Health Ltd., The Tower,
St George Wharf, London SW82BW, U.K.
| | - William Clarke
- Department
of Pathology, Johns Hopkins University School
of Medicine, Baltimore, Maryland 21205, United States
| | - Neel Patel
- ZiO
Health Ltd., The Tower,
St George Wharf, London SW82BW, U.K.
| | - Netzahualcóyotl Arroyo-Currás
- Biochemistry,
Cellular and Molecular Biology Program, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- Department
of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
| |
Collapse
|
2
|
Simple and rapid method for analysis of urinary vancomycin using solid phase extraction and fluorescence spectroscopy. AAPS OPEN 2023. [DOI: 10.1186/s41120-023-00071-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
AbstractVancomycin (VCM) is an antimicrobial that is recommended for therapeutic drug monitoring (TDM) for maintaining the efficacy and safety of treatment. The trough monitoring has been used to guide VCM dosing regimens. However, newer guidelines recommend the use of area under the curve/minimum inhibitory concentration (AUC/MIC)-guided vancomycin dosing, and there is a need for easier and more frequent measurements of VCM concentrations. Therefore, in this study, we developed a simple and rapid analytical method for measuring urinary VCM by combining solid-phase extraction and fluorescence analysis. Urine samples are easier and less invasive than blood samples. In addition to the therapeutic range of blood VCM, this method was also able to measure 0.01–1 mg/mL, which is the concentration range of urinary VCM. The accuracy of 10, 20, and 30 μg/mL VCM solutions were between 93.18 and 109.76%. The relative standard deviation (RSD) of intra-day and inter-day analysis were less than 6.25% and 6.28%, respectively. Since this method does not use large equipment, it is expected to be better suited for clinical use.
Collapse
|
3
|
Shaver A, Mahlum J, Scida K, Johnston ML, Aller Pellitero M, Wu Y, Carr GV, Arroyo-Currás N. Optimization of Vancomycin Aptamer Sequence Length Increases the Sensitivity of Electrochemical, Aptamer-Based Sensors In Vivo. ACS Sens 2022; 7:3895-3905. [PMID: 36417705 PMCID: PMC9791989 DOI: 10.1021/acssensors.2c01910] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 11/14/2022] [Indexed: 11/24/2022]
Abstract
The measurement of serum vancomycin levels at the clinic is critical to optimizing dosing given the narrow therapeutic window of this antibiotic. Current approaches to quantitate serum vancomycin levels are based on immunoassays, which are multistep methods requiring extensive processing of patient samples. As an alternative, vancomycin-binding electrochemical, aptamer-based sensors (E-ABs) were developed to simplify the workflow of vancomycin monitoring. E-ABs enable the instantaneous measurement of serum vancomycin concentrations without the need for sample dilution or other processing steps. However, the originally reported vancomycin-binding E-ABs had a dissociation constant of 45 μM, which is approximately 1 order of magnitude higher than the recommended trough concentrations of vancomycin measured in patients. This limited sensitivity hinders the ability of E-ABs to accurately support vancomycin monitoring. To overcome this problem, here we sought to optimize the length of the vancomycin-binding aptamer sequence to enable a broader dynamic range in the E-AB platform. Our results demonstrate, via isothermal calorimetry and E-AB calibrations in undiluted serum, that superior affinity and near-equal sensor gain in vitro can be achieved using a one-base-pair-longer aptamer than the truncated sequence originally reported. We validate the impact of the improved binding affinity in vivo by monitoring vancomycin levels in the brain cortex of live mice following intravenous administration. While the original sequence fails to resolve vancomycin concentrations from baseline noise (SNR = 1.03), our newly reported sequence provides an SNR of 1.62 at the same dose.
Collapse
Affiliation(s)
- Alexander Shaver
- Department
of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
| | - J.D. Mahlum
- Chemistry-Biology
Interface Program, Zanvyl Krieger School of Arts & Sciences, Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Karen Scida
- Lieber
Institute for Brain Development, Johns Hopkins
University School of Medicine, Baltimore, Maryland 21205, United States
| | - Melanie L. Johnston
- Department
of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- Biochemistry,
Cellular and Molecular Biology, Johns Hopkins
University School of Medicine, Baltimore, Maryland 21287, United States
| | - Miguel Aller Pellitero
- Department
of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
| | - Yao Wu
- Department
of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
| | - Gregory V. Carr
- Department
of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- Lieber
Institute for Brain Development, Johns Hopkins
University School of Medicine, Baltimore, Maryland 21205, United States
| | - Netzahualcóyotl Arroyo-Currás
- Department
of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- Chemistry-Biology
Interface Program, Zanvyl Krieger School of Arts & Sciences, Johns Hopkins University, Baltimore, Maryland 21218, United States
- Biochemistry,
Cellular and Molecular Biology, Johns Hopkins
University School of Medicine, Baltimore, Maryland 21287, United States
| |
Collapse
|
4
|
Cheng X, Ma J, Su J. An Overview of Analytical Methodologies for Determination of Vancomycin in Human Plasma. Molecules 2022; 27:molecules27217319. [PMID: 36364147 PMCID: PMC9658014 DOI: 10.3390/molecules27217319] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 10/12/2022] [Accepted: 10/26/2022] [Indexed: 11/22/2022] Open
Abstract
Vancomycin is regarded as the last resort of defense for a wide range of infections due to drug resistance and toxicity. The detection of vancomycin in plasma has always aroused particular concern because the performance of the assay affects the clinical treatment outcome. This article reviews various methods for vancomycin detection in human plasma and analyzes the advantages and disadvantages of each technique. Immunoassay has been the first choice for vancomycin concentration monitoring due to its simplicity and practicality, occasionally interfered with by other substances. Chromatographic methods have mainly been used for scientific research due to operational complexity and the particular requirement of the instrument. However, the advantages of a small amount of sample needed, high sensitivity, and specificity makes chromatography irreplaceable. Other methods are less commonly used in clinical applications because of the operational feasibility, clinical application, contamination, etc. Simplicity, good performance, economy, and environmental friendliness have been points of laboratory methodological concern. Unfortunately, no one method has met all of the elements so far.
Collapse
Affiliation(s)
| | | | - Jianrong Su
- Correspondence: or ; Tel.: +86-188-1169-5991
| |
Collapse
|
5
|
Reagentless Sensing of Vancomycin Using an Indium Tin Oxide Electrode Grafted with Molecularly Imprinted Polymer including Ferrocenyl Group. SENSORS 2021; 21:s21248338. [PMID: 34960432 PMCID: PMC8706183 DOI: 10.3390/s21248338] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 12/03/2021] [Accepted: 12/10/2021] [Indexed: 11/17/2022]
Abstract
Vancomycin (VCM) is a first-line antimicrobial agent against methicillin-resistant Staphylococcus aureus, a cause of nosocomial infections. Therapeutic drug monitoring is strongly recommended for VCM-based chemotherapy. The authors attempted to develop a simple VCM sensor based on molecularly imprinted polymer (MIP), which can be used with simple operations. Methacrylic acid (MAA), acrylamide, methylenebisacrylamide, and allylamine carboxypropionate-3-ferrocene (ACPF) were copolymerized in the presence of VCM and grafted from the surface of indium-tin oxide (ITO) to obtain MIP-coated electrodes. The MIP-grafted ITO electrode was used for differential pulse voltammetry (DPV) measurements in a buffer solution containing VCM or whole bovine blood. The obtained current depends on the VCM concentration with high linearity. The dynamic range covered the therapeutic range (20–40 μg/mL) of the VCM but was almost insensitive to teicoplanin, which has a similar structure to VCM. The ITO electrodes grafted by the same procedure except for omitting either VCM or APCF were not sensitive to VCM. The sensitivity of the MIP electrodes to VCM in whole blood and buffered saline, but the background current in blood was higher than that in saline. This high background current was also seen in the deproteinized plasma. Thus, the current is probably originated from the oxidation of low molecular weight reducing agents in the blood. The MIP-grafted ITO electrode using ACPF as a functional monomer would be a promising highly selective sensor for real-time monitoring of VCM with proper correction of the background current.
Collapse
|