Shimada T, Kawakami D, Fujita A, Yamamoto R, Hara S, Ito K, Mizushima I, Kitajima S, Iwata Y, Sakai N, Kawano M, Wada T, Sai Y. Validation of an automated sample preparation module directly connected to LC-MS/MS (CLAM-LC-MS/MS system) and comparison with conventional immunoassays for quantitation of tacrolimus and cyclosporin A in a clinical setting. J Pharm Health Care Sci 2024; 10:5. [PMID: 38191469 PMCID: PMC10773076 DOI: 10.1186/s40780-023-00318-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 11/13/2023] [Indexed: 01/10/2024] Open
Abstract
BACKGROUND Therapeutic drug monitoring (TDM) systems generally use either liquid chromatography/tandem mass spectrometry (LC-MS/MS) or immunoassay, though both methodologies have disadvantages. In this study, we aimed to evaluate whether a CLAM-LC-MS/MS system, which consists of a sample preparation module directly connected to LC-MS/MS, could be used for clinical TDM work for immunosuppressive drugs in whole blood, which requires a hemolytic process. For this purpose, we prospectively validated this system for clinical measurement of tacrolimus and cyclosporin A in patients' whole blood. The results were also compared with those of commercial immunoassays. METHODS Whole blood from patients treated with tacrolimus or cyclosporin A at the Department of Nephrology and Departments of Rheumatology, Kanazawa University Hospital, from May 2018 to July 2019 was collected with informed consent, and drug concentrations were measured by CLAM-LC-MS/MS and by chemiluminescence immunoassay (CLIA) for tacrolimus and affinity column-mediated immunoassay (ACMIA) for cyclosporin A. Correlations between the CLAM-LC-MS/MS and immunoassay results were analyzed. RESULTS Two hundred and twenty-four blood samples from 80 patients were used for tacrolimus measurement, and 76 samples from 21 patients were used for cyclosporin A. Intra- and inter-assay precision values of quality controls were less than 7%. There were significant correlations between CLAM-LC-MS/MS and the immunoassays for tacrolimus and cyclosporin A (Spearman rank correlation coefficients: 0.861, 0.941, P < 0.00001 in each case). The drug concentrations measured by CLAM-LC-MS/MS were about 20% lower than those obtained using the immunoassays. CLAM-LC-MS/MS maintenance requirements did not interfere with clinical operations. Compared to manual pretreatment, automated pretreatment by CLAM showed lower inter-assay precision values and greatly reduced the pretreatment time. CONCLUSIONS The results obtained by CLAM-LC-MS/MS were highly correlated with those of commercial immunoassay methods. CLAM-LC-MS/MS offers advantages in clinical TDM practice, including simple, automatic pretreatment, low maintenance requirement, and avoidance of interference.
Collapse
Affiliation(s)
- Tsutomu Shimada
- Department of Clinical Pharmacokinetics, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.
- Department of Hospital Pharmacy, University Hospital, Kanazawa University, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
| | - Daisuke Kawakami
- Shimadzu Corporation, Kyoto, Japan
- Shimadzu Europa GmbH, Duisburg, Germany
| | - Arimi Fujita
- Department of Clinical Pharmacokinetics, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
- Department of Hospital Pharmacy, University Hospital, Kanazawa University, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan
| | | | - Satoshi Hara
- Department of Rheumatology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Kiyoaki Ito
- Department of Rheumatology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Ichiro Mizushima
- Department of Rheumatology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Shinji Kitajima
- Department of Nephrology and Laboratory Medicine, Faculty of Medicine, Institute of Medical, Pharmaceutical and Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Yasunori Iwata
- Department of Nephrology and Laboratory Medicine, Faculty of Medicine, Institute of Medical, Pharmaceutical and Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Norihiko Sakai
- Department of Nephrology and Laboratory Medicine, Faculty of Medicine, Institute of Medical, Pharmaceutical and Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Mitsuhiro Kawano
- Department of Rheumatology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Takashi Wada
- Department of Nephrology and Laboratory Medicine, Faculty of Medicine, Institute of Medical, Pharmaceutical and Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Yoshimichi Sai
- Department of Clinical Pharmacokinetics, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
- Department of Hospital Pharmacy, University Hospital, Kanazawa University, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan
- AI Hospital/Macro Signal Dynamics Research and Development Center, Kanazawa University, Kanazawa, Ishikawa, Japan
| |
Collapse
|
2
|
Fraissinet F, Pereira T, Violin A, Feugray G, Bach-Ngohou K, Brunel V. A novel fully-automated method to measure steroids in serum by liquid chromatography-tandem mass spectrometry. J Mass Spectrom Adv Clin Lab 2023; 27:24-32. [PMID: 36593910 PMCID: PMC9804132 DOI: 10.1016/j.jmsacl.2022.12.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 11/24/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
Background Steroids play a key role in numerous physiological processes. Steroid determination is a useful tool to explore various endocrine diseases. Because of its specificity, mass spectrometry is considered to be a reference method for the determination of steroids in serum compared to radioimmunoassay. This technology could progress towards more automation for the optimal organization of clinical laboratories and ultimately for the benefit of patients. Methods A fully automated ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed and fully validated to determine five steroids in serum. Sample preparation was based on protein precipitation with filtration followed by online solid phase extraction. Chromatographic separation was performed using a biphenyl stationary phase. Results The method was successfully validated according to European Medicine Agency guidelines. Coefficients of variation did not exceed, respectively, 8.4% and 8.1% for intra- and inter-assay precision. Method comparison with radioimmunoassay showed a proportional bias for all compounds, except for testosterone in men. Comparison with another LC-MS/MS method demonstrated acceptable concordance for all steroids, although a small bias was observed for androstenedione. Conclusion The novelty of this method is that it has been fully automated. Automation provides benefits in traceability and allows significant savings in cost and time.
Collapse
Key Words
- 11DF, 11-deoxycortisol
- 17OHP, 17-hydroxyprogesterone
- 2D-UHPLC-MS/MS, Two dimensional ultra-high performance liquid chromatography-tandem mass spectrometry
- Automation
- D4, delta4-androstenedione
- DHEA, dehydroepiandrosterone
- EMA, European Medicine Agency
- GC–MS/MS, Gas chromatography tandem mass spectrometry
- LC-MS/MS, Liquid chromatography tandem mass spectrometry
- LLE, Liquid-liquid extraction
- LLOQ, Lower limit of quantification
- Liquid chromatography tandem mass spectrometry
- MRM, Multiple reaction monitoring
- PTFE, Polytetrafluoroethylene
- QC, Quality control
- RIA, Radioimmunoassay
- Radioimmunoassay
- SLE, Supported liquid extraction
- SPE, Solid phase extraction
- SRM, Standard reference material
- Steroids
- T, Testosterone
- Testosterone
- UHPLC, Ultra-high performance liquid chromatography
Collapse
Affiliation(s)
- François Fraissinet
- Department of General Biochemistry, Rouen University Hospital, 76000 Rouen, France
| | - Tony Pereira
- Department of General Biochemistry, Rouen University Hospital, 76000 Rouen, France
| | - Alizée Violin
- Nantes Université, CHU Nantes, Department of Biology, Laboratory of Biochemistry, F-44000 Nantes, France
| | - Guillaume Feugray
- Department of General Biochemistry, Rouen University Hospital, 76000 Rouen, France
- Normandie University, UNIROUEN, INSERM U1096 Rouen, France
| | - Kalyane Bach-Ngohou
- Nantes Université, CHU Nantes, Department of Biology, Laboratory of Biochemistry, F-44000 Nantes, France
- Nantes Université, CHU Nantes, INSERM, The Enteric Nervous System in Gut and Brain Disorders, IMAD, F-44000 Nantes, France
| | - Valéry Brunel
- Department of General Biochemistry, Rouen University Hospital, 76000 Rouen, France
| |
Collapse
|
3
|
Taniguchi M, Takamura N, Watanabe T, Ishimaru R, Chinaka S, Miki A, Miyazaki H, Tsuchihashi H, Zaitsu K. Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry. Chromatographia 2022; 85:1051-1063. [PMID: 36341308 PMCID: PMC9617228 DOI: 10.1007/s10337-022-04212-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 09/02/2022] [Accepted: 10/18/2022] [Indexed: 11/23/2022]
Abstract
In this study, we developed an easily operable quantification method for 21 plant-derived alkaloids in human serum by automatic sample preparation and liquid chromatography-tandem mass spectrometry. We designed to perform parallel sample preparation by a developed apparatus, which increased sample throughput. We conducted an automatic sample preparation through de-proteinization with 0.1% formic acid in methanol and achieved recovery rates of 89-107% (2.0-14% RSD) for all targeted analytes, demonstrating its high repeatability. The method validation results were satisfactory as follows: the linearity (r 2) of each calibration curve ranged from 0.978 to 1.000; the inter- and intra-day accuracies were 89.0-125% and 82.1-110%, respectively; the inter- and intra-day precisions were below 13% and 10%, respectively. Additionally, the lower limits of detection and quantification were 0.0044-0.047 and 0.013-0.14 ng/mL, respectively. Finally, the developed method was applied to pseudo-protoveratrine A poisoning serum and pseudo-colchicine poisoning serum, which were prepared by diluting acute-poisoning mice serum with human serum. Our method successfully quantitated protoveratrine A (0.15-0.25 ng/mL) and colchicine (4.8-6.0 ng/mL). Thus, our method is essential for prompt clinical treatment and critical care on patient in acute intoxication cases caused by plant-derived alkaloids. Supplementary Information The online version contains supplementary material available at 10.1007/s10337-022-04212-5.
Collapse
Affiliation(s)
- Masaru Taniguchi
- Nagoya City Public Health Research Institute, 2266-132 Anagahora, Shimoshidami, Moriyama-Ku, Nagoya, 463-8585 Japan
| | - Naoki Takamura
- Shimadzu Engineering Inc., 1 Nishinokyo Kuwabara-Cho, Nakagyo-Ku, Kyoto, 604-8511 Japan
| | - Tsutomu Watanabe
- Shimadzu Engineering Inc., 1 Nishinokyo Kuwabara-Cho, Nakagyo-Ku, Kyoto, 604-8511 Japan
| | - Reiko Ishimaru
- Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, 1-1 Kuratsuki, Kanazawa, Ishikawa 920-8553 Japan
| | - Satoshi Chinaka
- Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, 1-1 Kuratsuki, Kanazawa, Ishikawa 920-8553 Japan
| | - Akihiro Miki
- Forensic Science Laboratory, Osaka Prefectural Police Headquarters, 1-3-18 Hommachi, Chuo-Ku, Osaka, 541-0053 Japan
| | - Hitoshi Miyazaki
- Nagoya City Public Health Research Institute, 2266-132 Anagahora, Shimoshidami, Moriyama-Ku, Nagoya, 463-8585 Japan
| | - Hitoshi Tsuchihashi
- Department of Legal Medicine and Bioethics, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550 Japan
| | - Kei Zaitsu
- Multimodal Informatics and Wide-Data Analytics Laboratory, Department of Computational Systems Biology, Faculty of Biology-Oriented Science and Technology, Kindai University, 930 Nishi Mitani, Kinokawa, Wakayama, 649-6493 Japan
| |
Collapse
|