1
|
Fabris AL, Pedersen-Bjergaard S, Øiestad EL, Rossi GN, Hallak JEC, Dos Santos RG, Costa JL, Yonamine M. Solvent-free parallel artificial liquid membrane extraction for drugs of abuse in plasma samples using LC-MS/MS. Anal Chim Acta 2024; 1301:342387. [PMID: 38553114 DOI: 10.1016/j.aca.2024.342387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Revised: 02/05/2024] [Accepted: 02/18/2024] [Indexed: 04/02/2024]
Abstract
BACKGROUND Parallel artificial liquid membrane extraction (PALME) is a 96-well plate setup variant of liquid-phase microextraction. Basic or acidic analytes are extracted in neutral form from the sample, through a supported liquid membrane (SLM), and into aqueous acceptor. PALME is already considered a green extraction technique, but in the current conceptual work, we sought to make it even greener by replacing the use of organic solvents with essential oils (EO). PALME was combined with LC-MS/MS for analysis of plasma samples and multiple drugs of abuse with toxicological relevance (amphetamines, phenethylamines, synthetic cathinones, designer benzodiazepines, ayahuasca alkaloids, lysergic acid diethylamide, and ketamine). RESULTS Fourteen EO were compared to organic solvents frequently used in PALME. The EO termed smart & sassy yielded the best analyte recovery for all drugs studied and was thus selected as SLM. Then, factorial screening and Box-Behnken were employed to optimize the technique. The extraction time, concentration of base, sample volume, and percentage of trioctylamine significantly impacted analyte recovery. The optimum values were defined as 120 min, 10 mmol/L of NaOH, 150 μL, and 0%, respectively. Once optimized, validation parameters were 1-100 ng mL-1 as linear range, accuracy ±16.4%, precision >83%, 1 ng mL-1 as limit of quantitation, 0.1-0.75 ng mL-1 as limit of detection, matrix effect <20%, and recovery 20-106%. Additionally, EO purchased from different production batches were tested and achieved acceptable reproducibility. Data were in compliance with requirements set by internationally accepted validation guidelines and the applicability of the technique was proven using authentic samples. SIGNIFICANCE In this study, the use of an EO provided a solvent-free sample preparation technique suited to extract different classes of drugs of abuse from plasma samples, dismissing the use of hazardous organic solvents. The method also provided excellent sample clean-up, thus being a simple and efficient tool for toxicological applications that is in agreement with the principles of sustainable chemistry.
Collapse
Affiliation(s)
- André Luis Fabris
- School of Pharmaceutical Sciences, University of São Paulo, São Paulo, SP, 05508-000, Brazil.
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316, Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100, Copenhagen, Denmark
| | - Elisabeth Leere Øiestad
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316, Oslo, Norway; Department of Forensic Sciences, Division of Laboratory Medicine, Oslo University Hospital, P.O. Box 4459 Nydalen, 0424, Oslo, Norway
| | - Giordano Novak Rossi
- Department of Neurosciences and Behavior, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil
| | - Jaime E Cecílio Hallak
- Department of Neurosciences and Behavior, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil; National Institute of Science and Technology - Translational Medicine, Brazil
| | - Rafael Guimarães Dos Santos
- Department of Neurosciences and Behavior, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil; National Institute of Science and Technology - Translational Medicine, Brazil
| | - Jose Luiz Costa
- Campinas Poison Control Center, University of Campinas, Campinas, SP, 13083-859, Brazil; Faculty of Pharmaceutical Sciences, University of Campinas, Campinas, SP, 13083-871, Brazil
| | - Mauricio Yonamine
- School of Pharmaceutical Sciences, University of São Paulo, São Paulo, SP, 05508-000, Brazil
| |
Collapse
|
2
|
Baglietto M, Benedetti B, Di Carro M, Magi E. Polar licit and illicit ingredients in dietary supplements: chemometric optimization of extraction and HILIC-MS/MS analysis. Anal Bioanal Chem 2024; 416:1679-1695. [PMID: 38334794 PMCID: PMC10899327 DOI: 10.1007/s00216-024-05173-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 01/16/2024] [Accepted: 01/24/2024] [Indexed: 02/10/2024]
Abstract
Many dietary supplements claim the ability to enhance sports performance and to improve the fitness of the consumers. Occasionally, along with legal ingredients, illicit compounds may be added without being labelled, leading to unintended doping. Hence, the aim of this study was to develop an analytical method to determine a set of 12 polar (logDpH=7 from -2.0 to +0.3) compounds including diuretics, stimulants, β2-agonists, methylxanthines, and sweeteners. Hydrophilic interaction liquid chromatography was chosen as separation strategy, coupled with tandem mass spectrometry. The instrumental method was optimized using a two-step design of experiments (DoE). Firstly, a Plackett-Burman (PB) DoE was performed to identify the more influencing variables affecting peak areas and chromatographic resolution among temperature, water percentage in the mobile phase, and flow rate, as well as type and concentration of buffers. Secondly, a D-optimal DoE was set, considering only the most significant variables from the PB-DoE results, achieving a deeper understanding of the retention mechanism. Sample processing by salt-assisted liquid-liquid extraction was studied through DoE as well, and the whole method showed recoveries in the range 40-107% and procedural precision ≤11% for all analytes. Finally, it was applied to real samples, in which the four methylxanthines and two artificial sweeteners were detected and quantified in the range of 0.02-192 mg g-1. These values were compared to the quantities declared on the DS labels, when possible. Furthermore, a sequence of MS/MS scans allowed detection of a signal in one of the samples, structurally similar to the β2-agonist clenbuterol.
Collapse
Affiliation(s)
- Matteo Baglietto
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, 16146, Genoa, Italy
| | - Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, 16146, Genoa, Italy.
| | - Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, 16146, Genoa, Italy
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, 16146, Genoa, Italy
| |
Collapse
|
3
|
Fabris AL, Martins AF, Costa JL, Yonamine M. A new application of the switchable hydrophilicity solvent-based homogenous liquid-liquid microextraction to analyze synthetic cannabinoids in plasma by LC-MS/MS. J Pharm Biomed Anal 2023; 234:115588. [PMID: 37517261 DOI: 10.1016/j.jpba.2023.115588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 07/05/2023] [Accepted: 07/14/2023] [Indexed: 08/01/2023]
Abstract
Synthetic cannabinoids are still a growing trend among drug users and consist of a group of hundreds of highly potent compounds. To investigate the use of such substances, sample preparation of biological matrices is a crucial step prior to instrumental analysis. Although different efficient extraction techniques have been proposed for that aim, they usually do not fit eco-friendly guidelines that have been gaining popularity in recent years, such as Green Analytical Toxicology. This work uses describes for the first time the use of switchable hydrophilicity solvent-based homogenous liquid-liquid microextraction (SHS-HLLME) for synthetic cannabinoids. This is a green technique that replaces highly toxic organic reagents for switchable hydrophilicity solvents (SHS), substances that can be either water-miscible or immiscible depending on their protonation. Thus, by simply adjusting the pH of the system, these SHS can be used as extraction solvents. A full optimization study including type of SHS, volume of protonated SHS, volume of NaOH, salting-out effect, and extraction time was performed. The optimized procedure consisted of precipitating the proteins of 300 µL of plasma with 300 µL of acetonitrile followed by centrifugation; evaporation of the organic solvent under N2 stream; addition of 500 µL of the protonated DPA, DPA-HCl (6 M) (1:1, v/v); addition of 500 µL of NaOH (10 M); and finally centrifugation and evaporation. Validation results showed determination coefficients ≥ 0.99 for the 0.1-10 ng/mL linear range; 0.01-0.08 ng/mL as limit of detection; 0.1 ng/mL as limit of quantitation; accuracy and imprecision were within acceptable ranges; matrix effect, recovery, and process efficiency ranged from -55.6 to 185.9%, 36-56.7%, and 18.5-148.4%, respectively. The SHS-HLLME herein described was fully optimized providing satisfactory recoveries of 31 synthetic cannabinoids at low concentrations requiring only 300 µL of plasma. In addition, the validation results showed that the technique is a reliable eco-friendly alternative for clinical and toxicological analysis.
Collapse
Affiliation(s)
- André Luis Fabris
- School of Pharmaceutical Sciences, University of São Paulo, São Paulo, SP 05508-000, Brazil.
| | - Aline Franco Martins
- Faculty of Medical Sciences, University of Campinas, Campinas, SP 13083-859, Brazil; Campinas Poison Control Center, University of Campinas, Campinas, SP 13083-859, Brazil
| | - Jose Luiz Costa
- Campinas Poison Control Center, University of Campinas, Campinas, SP 13083-859, Brazil; Faculty of Pharmaceutical Sciences, University of Campinas, Campinas, SP 13083-871, Brazil
| | - Mauricio Yonamine
- School of Pharmaceutical Sciences, University of São Paulo, São Paulo, SP 05508-000, Brazil
| |
Collapse
|