1
|
Suner L, Sourdeau E, Ranaweera T, Tarfi S, Ronez E, Trichet C, Chapuis N, Lefebvre T, Debliquis A, Boyer T, Sandrine G, Mestrallet F, Broutier H, Dindinaud E, Rault E, Reinhard-Chegaray AS, Delhommeau F, Bardet V. Clinical and biological characteristics of patients presenting with carcinocythaemia: A retrospective, multicentre study by the French-speaking Cellular Hematology Group (GFHC). Br J Haematol 2024; 205:2041-2044. [PMID: 39183701 DOI: 10.1111/bjh.19728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2024] [Accepted: 08/13/2024] [Indexed: 08/27/2024]
Affiliation(s)
- Ludovic Suner
- Sorbonne Université, INSERM, Centre de Recherche Saint-Antoine, CRSA, AP-HP, SIRIC CURAMUS, Hôpital Saint-Antoine, Service d'Hématologie Biologique, Paris, France
| | - Elise Sourdeau
- Sorbonne Université, Service d'Hématologie Biologique, Hôpital Pitié-Salpêtrière, APHP, Paris, France
| | - Thimali Ranaweera
- Hematology and Immunology Department, Henri Mondor University Hospital, Assistance Publique-Hôpitaux de Paris, UPEC, Créteil, France
| | - Sihem Tarfi
- Hematology and Immunology Department, Henri Mondor University Hospital, Assistance Publique-Hôpitaux de Paris, UPEC, Créteil, France
| | - Emilie Ronez
- Service d'Hématologie-Immunologie-Transfusion, CHU Ambroise Paré, INSERM UMR 1184, AP-HP, Université Versailles Saint-Quentin -Université Paris Saclay, Boulogne Billancourt, France
| | - Catherine Trichet
- Service d'Hématologie Biologique, Hôpital Beaujon, AP-HP Nord Université de Paris, Clichy, France
| | - Nicolas Chapuis
- Assistance Publique-Hôpitaux de Paris, Centre-Université Paris Cité, Service d'hématologie Biologique, Hôpital Cochin, Paris, France
| | - Thomas Lefebvre
- Laboratoire d'Hématologie, Hôpitaux Civils de Colmar, Colmar, France
| | - Agathe Debliquis
- Laboratoire d'Hématologie, Groupe Hospitalier de la région Mulhouse Sud Alsace, Mulhouse, France
| | - Thomas Boyer
- Service d'Hematologie Biologique, CHU Amiens, Amiens, France
| | - Girard Sandrine
- Service d'Hématologie Biologique, Centre de Biologie et de Pathologie Est, Groupement Hospitalier Est, Hospices Civils de Lyon, Bron, France
| | - Fanélie Mestrallet
- Service d'Hématologie Biologique, Centre de Biologie et de Pathologie Est, Groupement Hospitalier Est, Hospices Civils de Lyon, Bron, France
| | - Hélène Broutier
- Laboratoire d'Hématologie, Grand Hôpital de l'Est Francilien, Meaux, France
| | | | | | | | - Francois Delhommeau
- Sorbonne Université, INSERM, Centre de Recherche Saint-Antoine, CRSA, AP-HP, SIRIC CURAMUS, Hôpital Saint-Antoine, Service d'Hématologie Biologique, Paris, France
| | - Valérie Bardet
- Service d'Hématologie-Immunologie-Transfusion, CHU Ambroise Paré, INSERM UMR 1184, AP-HP, Université Versailles Saint-Quentin -Université Paris Saclay, Boulogne Billancourt, France
| |
Collapse
|
2
|
Gulati G, Uppal G, Gong J. Unreliable Automated Complete Blood Count Results: Causes, Recognition, and Resolution. Ann Lab Med 2022; 42:515-530. [PMID: 35470271 PMCID: PMC9057813 DOI: 10.3343/alm.2022.42.5.515] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/05/2022] [Accepted: 04/05/2022] [Indexed: 12/03/2022] Open
Abstract
Automated hematology analyzers generate accurate complete blood counts (CBC) results on nearly all specimens. However, every laboratory encounters, at times, some specimens that yield no or inaccurate result(s) for one or more CBC parameters even when the analyzer is functioning properly and the manufacturer’s instructions are followed to the letter. Inaccurate results, which may adversely affect patient care, are clinically unreliable and require the attention of laboratory professionals. Laboratory professionals must recognize unreliable results, determine the possible cause(s), and be acquainted with the ways to obtain reliable results on such specimens. We present a concise overview of the known causes of unreliable automated CBC results, ways to recognize them, and means commonly utilized to obtain reliable results. Some examples of unreliable automated CBC results are also illustrated. Pertinent analyzer-specific information can be found in the manufacturers’ operating manuals.
Collapse
Affiliation(s)
- Gene Gulati
- Division of Hematopathology, Department of Pathology, Anatomy, and Cell Biology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
| | - Guldeep Uppal
- Division of Hematopathology, Department of Pathology, Anatomy, and Cell Biology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
| | - Jerald Gong
- Division of Hematopathology, Department of Pathology, Anatomy, and Cell Biology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|