Evaluating Shunt Survival Following Ventriculoperitoneal Shunting with and without Stereotactic Navigation in Previously Shunt-Naïve Patients.
World Neurosurg 2020;
136:e671-e682. [PMID:
31996335 DOI:
10.1016/j.wneu.2020.01.138]
[Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2019] [Revised: 01/16/2020] [Accepted: 01/18/2020] [Indexed: 11/23/2022]
Abstract
BACKGROUND
Ventriculoperitoneal shunts are used to alleviate elevated intracranial pressure due to either hydrocephalus or idiopathic intracranial hypertension; however, shunt failure is a significant neurosurgical problem. Despite increases in intraoperative stereotactic navigation usage over the past decade, its effect on shunt survival remains unclear.
METHODS
Shunt-naïve pediatric and adult patients receiving ventriculoperitoneal shunting between 2007 and 2015 were identified in a national administrative database. Multivariable logistic and Cox regressions were used to evaluate factors affecting stereotaxy usage and shunt survival. Matched cohorts were generated by propensity score balancing.
RESULTS
Of 9677 patients identified, 932 received image-guided shunt placement. Total shunt failure rate was not associated with stereotaxy use (20.3% with stereotaxy vs. 19.4% without, P = 0.4602). In the matched setting, shunt survival was not extended by use of image guidance during placement (hazard ratio = 1.134, 95% confidence interval 0.923-1.393). Late shunt failures (defined as failures occurring at least 30 days after shunt placement) caused by infection occurred more frequently in the stereotaxy cohort (hazard ratio = 2.207, 95% confidence interval 1.115-4.366), whereas late shunt failures attributable to mechanical shunt failure were more common in the nonstereotaxy cohort (hazard ratio = 1.406, 95% confidence interval 1.002-1.973).
CONCLUSIONS
Our findings suggest stereotaxy use during ventriculoperitoneal shunt placement does not affect shunt survival. Late shunt failures caused by infection occurred more frequently in the stereotaxy cohort, whereas late failures caused by mechanical shunt malfunction were more commonly encountered in the nonstereotaxy cohort.