1
|
Paniagua AT, Paranjape K, Hu M, Bédard E, Faucher SP. Impact of temperature on Legionella pneumophila, its protozoan host cells, and the microbial diversity of the biofilm community of a pilot cooling tower. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 712:136131. [PMID: 31931228 DOI: 10.1016/j.scitotenv.2019.136131] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 12/13/2019] [Accepted: 12/13/2019] [Indexed: 06/10/2023]
Abstract
Legionella pneumophila is a waterborne bacterium known for causing Legionnaires' Disease, a severe pneumonia. Cooling towers are a major source of outbreaks, since they provide ideal conditions for L. pneumophila growth and produce aerosols. In such systems, L. pneumophila typically grow inside protozoan hosts. Several abiotic factors such as water temperature, pipe material and disinfection regime affect the colonization of cooling towers by L. pneumophila. The local physical and biological factors promoting the growth of L. pneumophila in water systems and its spatial distribution are not well understood. Therefore, we built a lab-scale cooling tower to study the dynamics of L. pneumophila colonization in relationship to the resident microbiota and spatial distribution. The pilot was filled with water from an operating cooling tower harboring low levels of L. pneumophila. It was seeded with Vermamoeba vermiformis, a natural host of L. pneumophila, and then inoculated with L. pneumophila. After 92 days of operation, the pilot was disassembled, the water was collected, and biofilm was extracted from the pipes. The microbiome was studied using 16S rRNA and 18S rRNA genes amplicon sequencing. The communities of the water and of the biofilm were highly dissimilar. The relative abundance of Legionella in water samples reached up to 11% whereas abundance in the biofilm was extremely low (≤0.5%). In contrast, the host cells were mainly present in the biofilm. This suggests that L. pneumophila grows in host cells associated with biofilm and is then released back into the water following host cell lysis. In addition, water temperature shaped the bacterial and eukaryotic community of the biofilm, indicating that different parts of the systems may have different effects on Legionella growth.
Collapse
Affiliation(s)
- Adriana Torres Paniagua
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada
| | - Kiran Paranjape
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada
| | - Mengqi Hu
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada
| | - Emilie Bédard
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada; Department of Civil Engineering, Polytechnique Montreal, P.O. Box 6079, Station Centre-Ville, Montreal, Quebec H3C 3A7, Canada.
| | - Sébastien P Faucher
- Department of Natural Resource Sciences, McGill University, 21111 Lakeshore Drive, Ste-Anne-de-Bellevue, Quebec, H9X 3V9, Canada.
| |
Collapse
|
2
|
Schwartz GG, Klug MG. Motor neuron disease mortality rates in U.S. states are associated with well water use. Amyotroph Lateral Scler Frontotemporal Degener 2016; 17:528-534. [PMID: 27324739 PMCID: PMC5152538 DOI: 10.1080/21678421.2016.1195409] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2016] [Revised: 04/04/2016] [Accepted: 04/25/2016] [Indexed: 12/12/2022]
Abstract
Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease with an unknown cause and invariably fatal outcome. We sought to evaluate a correlation between motor neuron disease (MND) mortality rates and residential radon levels that was previously reported for counties in the United Kingdom. We examined the relationships between age-adjusted MND mortality rates in U.S. states with residential radon levels, well water use, and other variables using structural equation modeling. We observed a significant correlation between MND mortality rates and radon levels. However, in structural equation models, radon did not have a significant, direct effect on MND mortality rates. Conversely, MND mortality rates were significantly and directly predicted by race and by the percentage of the population of each state using well water (p < 0.001 and p = 0.022). We observed similar, significant effects for well water use and MND mortality for males and females separately (p < 0.05). In conclusion, we hypothesize that the association of MND mortality rates with well water use reflects contamination of wells with Legionella, a bacterium common in well water that is known to cause neurologic disease. A Legionella hypothesis is a biologically plausible cause of ALS and suggests new avenues for etiologic research.
Collapse
Affiliation(s)
- Gary G. Schwartz
- Department of Population Health, University of North Dakota School of Medicine & Health Sciences,
Grand Forks,
ND,
USA
| | - Marilyn G. Klug
- Department of Population Health, University of North Dakota School of Medicine & Health Sciences,
Grand Forks,
ND,
USA
| |
Collapse
|
3
|
|
4
|
Qu PH, Li Y, Salam N, Chen SY, Liu L, Gu Q, Fang BZ, Xiao M, Li M, Chen C, Li WJ. Allofrancisella inopinata gen. nov., sp. nov. and Allofrancisella frigidaquae sp. nov., isolated from water-cooling systems, and transfer of Francisella guangzhouensis Qu et al. 2013 to the new genus as Allofrancisella guangzhouensis comb. nov. Int J Syst Evol Microbiol 2016; 66:4832-4838. [PMID: 27543089 DOI: 10.1099/ijsem.0.001437] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Five bacterial strains (SYSU YG23T, SYSU 10HL1970T, 10HP82-10, 10HL1938, 10HP457) isolated from water reservoirs of cooling systems were characterized using a polyphasic taxonomic approach. The isolates were Gram-stain-negative, strictly aerobic and non-motile. Growth was enhanced in the presence of l-cysteine. The major fatty acids (>5 %) for the five strains were C10 : 0, C16 : 0, C16 : 0 3-OH, C18 : 0 3-OH and C18 : 1ω9c. Ubiquinone-8 was detected as the respiratory quinone while the polar lipid profile consisted of phosphatidylethanolamine, diphosphatidylglycerol, phosphatidylglycerol, phosphatidylcholine, three unidentified phospholipids, two unidentified aminophospholipids and three unidentified glycolipids. The strains shared 16S rRNA gene sequence similarities of 99.0-99.2 % with Francisella guangzhouensis 08HL01032T but less than 95.2 % with other members of the family Francisellaceae. The phylogenetic dendrogram based on 16S rRNA gene sequences showed that these strains form a separate cluster along with Francisella guangzhouensis. This cluster was also confirmed from multilocus-sequence typing based on sequences of the mdhA, rpoB and sdhA genes. Matrix-assisted laser desorption ionization time-of-flight MS analyses of the strains along with closely and distantly related Francisella strains also showed a distinct cluster for these strains. Based on the findings from the polyphasic taxonomy studies, the strains were considered to represent two novel species of a new genus for which the names Allofrancisella inopinata gen. nov., sp. nov. (type strain SYSU YG23T=KCTC 42968T=DSM 101834T) and Allofrancisella frigidaquae sp. nov. (type strain SYSU 10HL1970T=KCTC 42969T=DSM 101835T) are proposed. In addition, Francisella guangzhouensisQu et al. 2013 is proposed to be transferred to this new genus as Allofrancisella guangzhouensis comb. nov.
Collapse
Affiliation(s)
- Ping-Hua Qu
- Department of Clinical Laboratory, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou 510006, PR China
| | - Ying Li
- Department of Clinical Laboratory, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou 510006, PR China
- School of Laboratory Medicine, Tianjin Medical University, Tianjin 300070, PR China
| | - Nimaichand Salam
- State Key Laboratory of Biocontrol and Guangdong Provincial Key Laboratory of Plant Resources, School of Life Sciences, Sun Yat-Sen University, Guangzhou 510275, PR China
| | - Shou-Yi Chen
- Department of Microbiological Laboratory, Guangzhou Center for Diseases Control and Prevention, Guangzhou 510440, PR China
| | - Lan Liu
- State Key Laboratory of Biocontrol and Guangdong Provincial Key Laboratory of Plant Resources, School of Life Sciences, Sun Yat-Sen University, Guangzhou 510275, PR China
| | - Quan Gu
- Department of Clinical Laboratory, Tangshan People's Hospital, Tangshan 063000, PR China
| | - Bao-Zhu Fang
- State Key Laboratory of Biocontrol and Guangdong Provincial Key Laboratory of Plant Resources, School of Life Sciences, Sun Yat-Sen University, Guangzhou 510275, PR China
| | - Min Xiao
- State Key Laboratory of Biocontrol and Guangdong Provincial Key Laboratory of Plant Resources, School of Life Sciences, Sun Yat-Sen University, Guangzhou 510275, PR China
| | - Mo Li
- Department of Clinical Laboratory, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou 510006, PR China
| | - Cha Chen
- Department of Clinical Laboratory, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou 510006, PR China
| | - Wen-Jun Li
- State Key Laboratory of Biocontrol and Guangdong Provincial Key Laboratory of Plant Resources, School of Life Sciences, Sun Yat-Sen University, Guangzhou 510275, PR China
| |
Collapse
|
5
|
Egan JR, Hall IM. A review of back-calculation techniques and their potential to inform mitigation strategies with application to non-transmissible acute infectious diseases. J R Soc Interface 2016; 12. [PMID: 25977955 DOI: 10.1098/rsif.2015.0096] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Back-calculation is a process whereby generally unobservable features of an event leading to a disease outbreak can be inferred either in real-time or shortly after the end of the outbreak. These features might include the time when persons were exposed and the source of the outbreak. Such inferences are important as they can help to guide the targeting of mitigation strategies and to evaluate the potential effectiveness of such strategies. This article reviews the process of back-calculation with a particular emphasis on more recent applications concerning deliberate and naturally occurring aerosolized releases. The techniques can be broadly split into two themes: the simpler temporal models and the more sophisticated spatio-temporal models. The former require input data in the form of cases' symptom onset times, whereas the latter require additional spatial information such as the cases' home and work locations. A key aspect in the back-calculation process is the incubation period distribution, which forms the initial topic for consideration. Links between atmospheric dispersion modelling, within-host dynamics and back-calculation are outlined in detail. An example of how back-calculation can inform mitigation strategies completes the review by providing improved estimates of the duration of antibiotic prophylaxis that would be required in the response to an inhalational anthrax outbreak.
Collapse
|
6
|
Large outbreak of Legionnaires' disease and Pontiac fever at a military base. Epidemiol Infect 2014; 142:2336-46. [DOI: 10.1017/s0950268813003440] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
SUMMARYWe investigated a mixed outbreak of Legionnaires' disease (LD) and Pontiac fever (PF) at a military base to identify the outbreak's environmental source as well as known legionellosis risk factors. Base workers with possible legionellosis were interviewed and, if consenting, underwent testing for legionellosis. A retrospective cohort study collected information on occupants of the buildings closest to the outbreak source. We identified 29 confirmed and probable LD and 38 PF cases. All cases were exposed to airborne pathogens from a cooling tower. Occupants of the building closest to the cooling tower were 6·9 [95% confidence interval (CI) 2·2–22·0] and 5·5 (95% CI 2·1–14·5) times more likely to develop LD and PF, respectively, than occupants of the next closest building. Thorough preventive measures and aggressive responses to outbreaks, including searching for PF cases in mixed legionellosis outbreaks, are essential for legionellosis control.
Collapse
|
7
|
Stein E. Comments concerning Legionella article. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2011; 8:D86-D87. [PMID: 21830876 DOI: 10.1080/15459624.2011.602285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
|
8
|
Rangel KM, Delclos G, Emery R, Symanski E. Assessing maintenance of evaporative cooling systems in legionellosis outbreaks. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2011; 8:249-265. [PMID: 21416443 DOI: 10.1080/15459624.2011.565409] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
This study was designed to conduct systematic reviews of existing evaporative cooling system maintenance guidelines and of published Legionnaires' disease outbreaks to determine what, if any, maintenance practices were in place at the time of the disease outbreaks and then to contrast the reported practices with the published guidelines for evaporative cooling systems. For the first review, similarities in the reported recommendations were assessed; in the second review, any reported information about the state of the evaporative cooling system during the outbreak investigation was summarized. The systematic reviews yielded 38 current guidelines for evaporative cooling systems and 38 published outbreak investigations. The guidelines varied regarding the recommended type and dose of biocides, frequency of general inspections and total system maintenance, the preferred disinfection and cleaning procedures when testing a system for microbiological contamination, the type and frequency of testing procedures, and interpretation of test results. Overall, the maintenance guidelines did not contain sufficiently detailed procedures to prevent the problems that were observed in the outbreak investigations. These maintenance procedures included lack or improper use of a biocide; infrequent testing for microbiological contamination; improper use or maintenance of drift eliminators; and lack of a total system cleaning within 6 months of the outbreak for cooling systems that were either under continuous use, recently started up, or frequently switched on and off. This study suggests that more specific and standardized maintenance guidelines for the control of Legionella bacteria are needed and that these guidelines must be properly implemented to help reduce further Legionnaires' disease outbreaks associated with evaporative cooling systems.
Collapse
Affiliation(s)
- Kelly M Rangel
- Division of Epidemiology, Human Genetics and Environmental Sciences, University of Texas School of Public Health, Houston, Texas 77030, USA.
| | | | | | | |
Collapse
|
9
|
Sala Ferré MR, Arias C, Oliva JM, Pedrol A, García M, Pellicer T, Roura P, Domínguez A. A community outbreak of Legionnaires’ disease associated with a cooling tower in Vic and Gurb, Catalonia (Spain) in 2005. Eur J Clin Microbiol Infect Dis 2008; 28:153-9. [DOI: 10.1007/s10096-008-0603-6] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2008] [Accepted: 07/24/2008] [Indexed: 10/21/2022]
|
10
|
Engelhart S, Pleischl S, Lück C, Marklein G, Fischnaller E, Martin S, Simon A, Exner M. Hospital-acquired legionellosis originating from a cooling tower during a period of thermal inversion. Int J Hyg Environ Health 2008; 211:235-40. [PMID: 17870669 DOI: 10.1016/j.ijheh.2007.07.022] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2007] [Revised: 04/30/2007] [Accepted: 07/15/2007] [Indexed: 11/22/2022]
Abstract
A case of hospital-acquired legionellosis occurred in a 75-year-old male patient who underwent surgery due to malignant melanoma. Legionellosis was proven by culture of Legionella pneumophila serogroup 1 from bronchoalveolar lavage (BAL) fluid. Being a chronic smoker the patient used to visit the sickroom balcony that was located about 90 m to the west of a hospital cooling tower. Routine cooling tower water samples drawn during the presumed incubation period revealed 1.0x10(4) CFU/100 ml (L. pneumophila serogroup 1). One of three isolates from the cooling tower water matched the patient's isolate by monoclonal antibody (mab)- and genotyping (sequence-based typing). Horizontal transport of cooling tower aerosols probably was favoured by meteorological conditions with thermal inversion. The case report stresses the importance of routine maintenance and microbiological control of hospital cooling towers.
Collapse
Affiliation(s)
- Steffen Engelhart
- Institute of Hygiene and Public Health, University of Bonn, Sigmund-Freud-Str. 25, 53105 Bonn, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Prevalence of antibodies in response to Legionella species, analysis of a healthy population from Jeollanam-do Province, Korea. J Microbiol 2008; 46:160-4. [DOI: 10.1007/s12275-007-0181-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2007] [Accepted: 02/21/2008] [Indexed: 10/22/2022]
|
12
|
Abstract
In Osier’s time, bacterial pneumonia was a dreaded event, so important that he borrowed John Bunyan’s characterization of tuberculosis and anointed the pneumococcus, as the prime pathogen, “Captain of the men of death.”1 One hundred years later much has changed, but much remains the same. Pneumonia is now the sixth most common cause of death and the most common lethal infection in the United States. Hospital-acquired pneumonia is now the second most common nosocomial infection.2 It was documented as a complication in 0.6% of patients in a national surveillance study,3 and has been reported in as many as 20% of patients in critical care units.4 Furthermore, it is the leading cause of death among nosocomial infections.5 Leu and colleagues6 were able to associate one third of the mortality in patients with nosocomial pneumonia to the infection itself. The increase in hospital stay, which averaged 7 days, was statistically significant. It has been estimated that nosocomial pneumonia produces costs in excess of $500 million each year in the United States, largely related to the increased length of hospital stay.
Collapse
|
13
|
Sabria M, Yu VL. Hospital-acquired legionellosis: solutions for a preventable infection. THE LANCET. INFECTIOUS DISEASES 2002; 2:368-73. [PMID: 12144900 DOI: 10.1016/s1473-3099(02)00291-8] [Citation(s) in RCA: 122] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Hospital-acquired Legionnaires' disease has been reported from many hospitals since the first outbreak in 1976. Although cooling towers were linked to the cases of Legionnaires' disease in the years after its discovery, potable water has been the environmental source for almost all reported hospital outbreaks. Microaspiration is the major mode of transmission in hospital-acquired Legionnaires' disease; showering is not a mode of transmission. Since the clinical manifestations are non-specific, and specialised laboratory testing is required, hospital-acquired legionellosis is easily underdiagnosed. Discovery of a single case of hospital-acquired Legionnaires' disease is an important sentinel of additional undiscovered cases. Routine environmental culture of the hospital water supply for legionella has proven to be an important strategy in prevention. Documentation of legionella colonisation in the water supply would increase physician index of suspicion for Legionnaires' disease and the necessity for in-house legionella test methods would be obvious. Legionella is a common commensal of large-building water supplies. Preventive maintenance is commonly recommended; unfortunately, this measure is ineffective in minimising legionella colonisation of building water supplies. Copper-silver ionisation systems have emerged as the most successful long-term disinfection method for hospital water disinfection systems. There is a need for public-health agencies to educate the public and media that discovery of cases identifies those hospitals as providers of superior care, and that such hospitals are not negligent.
Collapse
Affiliation(s)
- Miguel Sabria
- Hospital Universitario Germans Trias I Pujol and the Autonomous University of Barcelona, Badalona, Spain
| | | |
Collapse
|
14
|
Loeb M, Simor AE, Mandell L, Krueger P, McArthur M, James M, Walter S, Richardson E, Lingley M, Stout J, Stronach D, McGeer A. Two nursing home outbreaks of respiratory infection with Legionella sainthelensi. J Am Geriatr Soc 1999; 47:547-52. [PMID: 10323647 PMCID: PMC7166437 DOI: 10.1111/j.1532-5415.1999.tb02568.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To describe outbreaks of infection caused by Legionella sainthelensi occurring in older residents of two nursing homes and to determine risk factors for the development of infection. DESIGN Descriptive epidemiology and a case-control study. SETTING Two nursing homes (140 beds and 254 beds in nursing homes A and B, respectively) located in southern Ontario, Canada, experiencing outbreaks of respiratory tract infection in July and August 1994. SUBJECTS Case-residents of the two nursing homes who met clinical and laboratory criteria for Legionella infection. Control-residents were defined as those who were in the homes during the outbreaks and were asymptomatic. MEASUREMENTS Active surveillance was conducted in both nursing homes to identify symptomatic residents. Residents with fever or respiratory tract symptoms had nasopharyngeal swabs taken for viral antigen detection and culture, urine for Legionella antigen detection, and acute and convalescent serology for viruses, Mycoplasma pneumoniae, Chlamydia pneumoniae, and Legionella. Chest X-rays were performed, and an attempt was made to obtain blood and sputum cultures. Water samples from shower heads, faucets, and air conditioning units were collected for Legionella culture and polymerase chain reaction (PCR) assay. A case-control study was done to assess possible risk factors for legionellosis. RESULTS Twenty-nine cases -- 17 in nursing home A; 12 in nursing home B - were identified. Four (14%) case-residents had documented pneumonia and four case-residents died. Univariate analysis revealed that a history of stroke (odds ratio (OR) 2.3 (95% CI, 1.0-5.3)), eating pureed food (OR 4.6 (95% CI, 1.6-12.7)), and having fluids administered with medication (OR 2.5 (95% CI, 1.0-5.9)) were significant risk factors. Cases were less likely to wear dentures (OR .4 (95% CI, .2-.9)) or to eat solid food (OR .3, (95% CI, .1-.6)). Only eating pureed food remained significant in a multivariable analysis (OR 4.6 (95% CI, 1.6-13.0, P = .01)). CONCLUSION This report describes outbreaks of legionellosis in two nursing homes, representing the first reported outbreaks of infection caused by Legionella sainthelensi. The association with illness of dietary characteristics indicative of swallowing disorders suggests that aspiration was the most likely mode of infection. The diagnosis of legionellosis should be considered during outbreaks of respiratory infection in nursing homes.
Collapse
Affiliation(s)
- M Loeb
- Division of Infectious Diseases, Hamilton Civic Hospitals and McMaster University, Ontario, Canada
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Kool JL, Fiore AE, Kioski CM, Brown EW, Benson RF, Pruckler JM, Glasby C, Butler JC, Cage GD, Carpenter JC, Mandel RM, England B, Breiman RF. More than 10 Years of Unrecognized Nosocomial Transmission of Legionnaires' Disease among Transplant Patients. Infect Control Hosp Epidemiol 1998. [DOI: 10.2307/30142014] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
16
|
Bell JC, Jorm LR, Williamson M, Shaw NH, Kazandjian DL, Chiew R, Capon AG. Legionellosis linked with a hotel car park--how many were infected? Epidemiol Infect 1996; 116:185-92. [PMID: 8620910 PMCID: PMC2271622 DOI: 10.1017/s0950268800052420] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
An outbreak of legionellosis associated with a hotel in Sydney, Australia, and the subsequent epidemiological and environmental investigations are described. Four cases of Legionnaires' disease were notified to the Public Health Unit. A cross-sectional study of 184 people who attended a seminar at the hotel was carried out. Serological and questionnaire data were obtained for 152 (83%) of these. Twenty-eight (18%) respondents reported symptoms compatible with legionellosis. Thirty-three subjects (22%) had indirect fluorescent antibody (IFA) titres to Legionella pneumophila serogroup 1 (Lp-1) of 128 or higher. The only site which those with symptoms of legionellosis and IFA titre > or = 128 were more likely to have visited than controls was the hotel car park (adjusted odds ratio [OR] 14.7, 95% confidence interval [CI]: 1.8-123.1). Those with symptoms compatible with legionellosis, but whose IFA titres were < 128 were also more likely to have visited the hotel car park (adjusted OR 4.4, 95% CI: 1.5-12.9). Seroprevalence of Lp-1 antibodies was higher in those who attended the seminar than in a population sample of similar age. Findings suggested that the 4 cases represented a small fraction of all those infected, and highlighted difficulties in defining illness caused by Lp-1 and in interpreting serology.
Collapse
Affiliation(s)
- J C Bell
- Western Sector Public Health Unit, North Parramatta NSW, Australia
| | | | | | | | | | | | | |
Collapse
|
17
|
Mazieri NA, de Godoy CV, Alves SF, de Andrade DR, Levin AS, Hablitzel AC. Legionnaires' disease in the renal transplant unit of "Hospital das Clinicas, FMUSP". During a five year period (1988-1993). Rev Inst Med Trop Sao Paulo 1994; 36:231-6. [PMID: 7855487 DOI: 10.1590/s0036-46651994000300007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Several reports have related Legionella pneumophila with pneumonia in renal transplant patients, however this association has not been systematically documented in Brazil. Therefore this paper reports the incidence, by serological assays, of Legionella pneumophila serogroup 1 in these patients during a five year period. For this purpose sera from blood samples of 70 hospitalized patients with pneumonia from the Renal Transplant Unit of Hospital das Clinicas, FMUSP collected at the acute and convalescent phase of infection were submitted to indirect immunofluorescence assay (IFA) to demonstrate anti-Legionella pneumophila serogroup 1 antibodies. Of these 70 patients studied during the period of 1988 to 1993, 18 (25.71%) had significant rises in specific antibody titers for Legionella pneumophila serogroup 1. Incidence was interrupted following Hospital water decontamination procedures, with recurrence of infections after treatment interruption. In this study, the high susceptibility (25.71%) of immunodepressed renal transplant patients to Legionella pneumophila serogroup 1 nosocomial infections is documented. The importance of the implementation and maintenance of water decontamination measures for prophylaxis of the infection is also clearly evident.
Collapse
Affiliation(s)
- N A Mazieri
- Laboratório de Investigação Médica (LIM-54), Hospital das Clinicas, Faculdade de Medicina, Universidade de São Paulo (HC-FMUSP), Brazil
| | | | | | | | | | | |
Collapse
|
18
|
Mazieri NADO, Godoy CVFD. Legionelose associada a pneumopatias em São Paulo: estudo da comprovação etiológica por isolamento e sorologia. Rev Inst Med Trop Sao Paulo 1993. [DOI: 10.1590/s0036-46651993000100001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A presença de Legionella sp como patógeno atuante em nosso país não fora bem documentada, embora a literatura refira a importância deste agente em grande número de países. O presente trabalho teve como objetivo a detecção do microrganismo ou evidenciar sua resposta imunológica em pacientes portadores de pneumopatias infecciosas na cidade de São Paulo. Para tanto foi introduzida metodologia laboratorial específica para o cultivo e identificação do agente e aplicada reação sorológica para verificação de níveis de anticorpos correspondentes. Foram estudados pacientes de 2 centros universitários em São Paulo, correspondentes a 100 do Hospital Universitário U.S.P. com pneumopatias infecciosas em geral e 100 do Hospital das Clínicas F.M.U.S.P. com pneumopatias infecciosas previamente selecionados para afastar outras etíologias bacterianas e dentre estes 30 pertencentes a Unidade de Transplante Renal. O material biológico destinado ao cultivo de Legionella sp foi constituído por: escarro, secreção traqueal, líquido pleural, lavado brônquico ou biópsia de tecido pulmonar. As tentativas de isolamento do agente foram realizadas em meio de BCYE com e sem antibióticos, a identificação das colônias, foram realizadas através de provas de crescimento em placas de BCYE sem cisteína, provas bioquímicas, imunofluorescência direta e soroaglutinação em lâmina. A pesquisa do agente em material biológico foi realizado pelo método de imunofluorescência direta. A pesquisa de anticorpos específicos para Legionella pneumophila sorogrupo 1 foi efetuada pela reação de imunofluorescência indireta. Procedeu-se ainda a estudo sorológico) nos comunicantes de pacientes com legionelose para evidenciar possível transmissão do agente. Em 2 casos obteve-se isolamento em cultura e em 4 casos, somente reação de imunofluorescência direta positiva para L. pneumophila sorogrupo 1, à partir do material biológico, representando um total de 6% entre pacientes da comunidade e hospitalares, comprovando desta forma a existência do agente entre nós. A reação sorológica de imunofluorescência indireta permitiu estabelecer infecção atual ou pregressa por Legionella pneumophila sorogrupo 1, em 16 dos 100 pacientes estudados no Hospital das Clínicas e em apenas 1 dos 100 pertencentes ao Hospital Universitário. Pacientes considerados como grupo de risco do Hospital das Clínicas correspondentes a transplantados renais mostraram evidências sorológicas de legionelose atual ou pregressa em 10 dos 30 estudados, isto é 33%, ficando com 8,5% para pacientes da comunidade, 6 dos 70 estudados, sendo 3 destes debilitados por doença sistêmica severa (4,28%). Nos profissionais de saúde comunicantes dos pacientes com legionelose internados no Hospital das Clínicas, apenas 1 em 28 revelou sorologia compatível com infecção pregressa, confirmando dados da literatura de não ser usual a transmissão de pessoa a pessoa
Collapse
|
19
|
|
20
|
Bhopal RS, Fallon RJ, Buist EC, Black RJ, Urquhart JD. Proximity of the home to a cooling tower and risk of non-outbreak Legionnaires' disease. BMJ (CLINICAL RESEARCH ED.) 1991; 302:378-83. [PMID: 2004142 PMCID: PMC1676166 DOI: 10.1136/bmj.302.6773.378] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
OBJECTIVE To study the source of non-outbreak legionnaires' disease, particularly the role of cooling towers, by comparing the locations of patients' homes in relation to the location of cooling towers. DESIGN Retrospective, descriptive study of a case series of patients with legionnaires' disease ill between 1978 and 1986 and, for comparison, a case series of patients with lung cancer. A prospectively developed register and interview based survey provided data on the location of cooling towers. SETTING The city of Glasgow. PATIENTS 134 patients aged 14-84 with legionnaires' disease during 1978-86 and 10,159 patients with lung cancer during the same period. MAIN OUTCOME MEASURES The locations of patients' homes and cooling towers as defined by postcodes, which provided map grid references accurate to 10 m; numbers of expected and observed cases of legionnaires' disease in census enumeration districts; and distance of enumeration districts from the nearest cooling tower as defined by five distance categories. RESULTS Most cooling towers were in or near the city centre or close to the River Clyde, as were the places of residence of patients with community acquired, non-travel, non-outbreak legionnaires' disease (n = 107). There was an inverse association between the distance of residence from any cooling tower and the risk of infection, the population living within 0.5 km of any tower having a relative risk of infection over three times that of people living more than 1 km away. There was no such association with respect to travel related legionnaires' disease, and for lung cancer the association was weak (relative risk less than or equal to 1.2 in any distance group). CONCLUSION In Glasgow cooling towers have been a source of infection in two outbreaks of legionnaires' disease and, apparently, a source of non-outbreak infection also. Better maintenance of cooling towers should help prevent non-outbreak cases. This method of inquiry should be applied elsewhere to study the source of this and other environmentally acquired disease.
Collapse
Affiliation(s)
- R S Bhopal
- Division of Epidemiology and Public Health, Medical School, University of Newcastle upon Tyne
| | | | | | | | | |
Collapse
|
21
|
Ring BA. Legionnaires' disease: the wollongong experience. THE AUSTRALIAN JOURNAL OF PHYSIOTHERAPY 1989; 35:167-176. [PMID: 25025484 DOI: 10.1016/s0004-9514(14)60506-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Australia experienced its largest Legionnaires' disease epidemic in Wollongong, mid 1987. This paper presents an overview of Legionnaires' disease followed by details of the Wollongong epidemic including areas of particular interest to the physiotherapist, with comparisons of milder and severe cases. Unlike other epidemics, females outnumbered males. Predisposing factors of increasing age, cigarette smoking, respiratory and medical conditions were found. Except cigarette smoking, these factors and initial chest radiograph involving two or more zones, were significant features of the severe group. Patients in these categories require careful monitoring. Blood gases demonstrated consistent hypoxaemia and hypocapnoea. Seventy-eight per cent of cases recorded little or no sputum and implications for treatment are discussed. Impressions and fears of the epidemic are presented and recommendations made.
Collapse
|
22
|
Domingue EL, Tyndall RL, Mayberry WR, Pancorbo OC. Effects of three oxidizing biocides on Legionella pneumophila serogroup 1. Appl Environ Microbiol 1988; 54:741-7. [PMID: 3377492 PMCID: PMC202534 DOI: 10.1128/aem.54.3.741-747.1988] [Citation(s) in RCA: 50] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
A study was conducted to determine the bactericidal effects of ozone and hydrogen peroxide relative to that of free chlorine on Legionella pneumophila serogroup 1. In laboratory batch-type experiments, organisms seeded at various densities were exposed to different concentrations of these biocides in demand-free buffers. Bactericidal effects were measured by determining the ability of L. pneumophila to grow on buffered charcoal-yeast extract agar supplemented with alpha-ketoglutarate. Ozone was the most potent of the three biocides, with a greater than 99% kill of L. pneumophila occurring during a 5-min exposure to 0.10 to 0.30 micrograms of O3 per ml. The bactericidal action of O3 was not markedly affected by changes in pH or temperature. Concentrations of 0.30 and 0.40 micrograms of free chlorine per ml killed 99% of the L. pneumophila after 30- and 5-min exposures, respectively. A 30-min exposure to 1,000 micrograms of H2O2 per ml was required to effect a 99% reduction of the viable L. pneumophila population. However, no viable L. pneumophila could be detected after a 24-h exposure to 100 or 300 micrograms of H2O2 per ml. Attempts were made to correlate the biocidal effects of O3 and H2O2 with the oxidation of L. pneumophila fatty acids. These tests indicated that certain biocidal concentrations of O3 and H2O2 resulted in a loss or severe reduction of L. pneumophila unsaturated fatty acids.
Collapse
Affiliation(s)
- E L Domingue
- Department of Environmental Health, Quillen-Dishner College of Medicine, East Tennessee State University, Johnson City 37614
| | | | | | | |
Collapse
|
23
|
|
24
|
Abstract
In the summer of 1976, a mysterious epidemic of fatal respiratory disease in Philadelphia launched an intensive investigation that resulted in the definition of a new family of pathogenic bacteria, the Legionellaceae. In retrospect, members of the family had been isolated from clinical specimens as early as 1943. Unsolved epidemics of acute respiratory disease dating to the 1950s were subsequently attributed to the newly described pathogens. In the intervening years, the Legionellaceae have been firmly established as important causes of sporadic and epidemic respiratory disease. The sources of the infecting bacteria are environmental, and geographic variation in the frequency of infection has been documented. Airborne dissemination of bacteria from cooling towers and evaporative condensers has been responsible for some epidemics, but potable water systems are perhaps more important sources. The mode of transmission from drinking water is unclear. The Legionellaceae are gram-negative, facultative, intracellular pathogens. The resident alveolar macrophage, usually an effective antibacterial defense, is the primary site of growth. Cell-mediated immunity appears to be the most important immunological defense; the role of humoral immunity is less clear. Erythromycin remains the antibiotic of choice for therapy of infected patients, but identification and eradication of environmental sources are also essential for the control of infection.
Collapse
Affiliation(s)
- W C Winn
- Department of Pathology, University of Vermont, College of Medicine, Burlington 05405
| |
Collapse
|
25
|
|
26
|
Johnston JM, Latham RH, Meier FA, Green JA, Boshard R, Mooney BR, Edelstein PH. Nosocomial outbreak of Legionnaires' disease: molecular epidemiology and disease control measures. INFECTION CONTROL : IC 1987; 8:53-8. [PMID: 3030951 DOI: 10.1017/s0195941700067072] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Molecular laboratory techniques were used to study the epidemiology of an outbreak of nosocomial Legionnaires' disease. All patient isolates were Legionella pneumophila serogroup 1 and showed identical plasmid profiles and reactions with serogroup-specific monoclonal antibodies. L pneumophila was also cultured from four of five cooling tower water samples; however, the isolate from only one tower was serogroup 1 of the same subtype as patient isolates. Since the cases were temporally clustered and epidemiologically associated with exposure to cooling tower aerosols, the single cooling tower implicated by molecular analysis was the most likely source of the outbreak. Chlorination of cooling tower ponds has eradicated the epidemic strain. Since potable water also harbored the infecting organism and was the probable source for cooling tower contamination, decontamination of the hospital water system was also undertaken. Superchlorination of hot water holding tanks to 17 ppm on a weekly basis has effectively eradicated L pneumophila from the potable water system and appears to be a reasonable, simple, and relatively inexpensive alternative to previously described methods of control.
Collapse
|
27
|
Kohler RB. Antigen detection for the rapid diagnosis of mycoplasma and Legionella pneumonia. Diagn Microbiol Infect Dis 1986; 4:47S-59S. [PMID: 2421969 DOI: 10.1016/s0732-8893(86)80042-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Immunologic attempts to detect mycoplasma antigens in fluids of infected patients have been rare and largely unsuccessful. Nucleic acid hybridization procedures appear promising on the basis of successes in detecting mycoplasmal contamination of tissue culture cells; results of attempts to apply these techniques to human infections have not been reported. Antigens can be detected in the urine of about 80% of patients with serogroup 1 Legionella pneumophila pneumonia and of some patients with serogroup 4 Legionella pneumophila and Legionella dumoffii pneumonia. The specificity of these assays is greater than 99%. In a test population in which the prevalence of Legionella pneumophila was 4%, the posterior probabilities of positive and negative results of tests for antigen were 86.5% and 99.3%, respectively. Antigen is detectable within the first 3 days of illness approximately as often as at later periods, and antigen may remain detectable for a few days to 1 yr after successful therapy. Antigen is detectable in serum, but the concentrations are considerably lower than in urine. Combining urinary antigen detection with direct fluorescent antibody examination of secretions increases the rapid diagnostic yield by 10%-20%. Monoclonal antibody studies demonstrate that subgroup specificities are present among the serogroup 1 urinary antigens. Radiometric and enzyme immunoassays detect antigen in equal proportions of patients. Latex agglutination results are positive in about 80% of those cases positive by the other methods.
Collapse
|
28
|
Nunnink JC, Gallagher JG, Yates JW. Legionnaires' disease in patients with cancer. MEDICAL AND PEDIATRIC ONCOLOGY 1986; 14:81-5. [PMID: 3713641 DOI: 10.1002/mpo.2950140205] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
A 4-year experience with Legionella pneumophila (LD) diagnosed in 36 patients with cancer was reviewed. Cancer patients represented 24% of the total population of patients acquiring LD during that time. Hematologic neoplasms (42%) and lung cancer (22%) accounted for the majority of afflicted patients. Nosocomial infections occurred in 42% of the patients evaluated. Several risk factors were assessed, and only neutropenia, and previous steroid therapy played a causal role (p less than .05) when assessed in a retrospective case control fashion. Overall mortality in oncology patients with LD (53%) was high and underscores the need rapidly to diagnose and treat this entity. This mortality decreased after 1977 when an effective antibiotic was utilized. Mixed infections also played a major role in outcome and occurred in 31% of the 36 patients studied. The mortality in these cancer patients was 73%, and this emphasizes the need to exclude and treat concomitant bacterial or fungal infections.
Collapse
|
29
|
Winn WC. Legionella and Legionnaires' disease: a review with emphasis on environmental studies and laboratory diagnosis. Crit Rev Clin Lab Sci 1985; 21:323-81. [PMID: 3881218 DOI: 10.3109/10408368509165787] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Legionella pneumophila and related species are important causes of epidemic bacterial pneumonia and nosocomial infection. This review will discuss this new family of bacteria and the diseases they produce. The classification, general microbiologic characteristics, and ecology of the bacteria will be reviewed and the epidemiology and clinical aspects of the infection will be discussed. More emphasis will be given to issues that are more directly related to laboratory workers and with which the author has had more direct experience: pathology, laboratory diagnosis of human infection, pathogenesis of the infection, and virulence mechanisms of the bacterium. Therapy and prevention of the infection will be discussed more briefly.
Collapse
|
30
|
Kohler RB, Winn WC, Wheat LJ. Onset and duration of urinary antigen excretion in Legionnaires disease. J Clin Microbiol 1984; 20:605-7. [PMID: 6490846 PMCID: PMC271393 DOI: 10.1128/jcm.20.4.605-607.1984] [Citation(s) in RCA: 120] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
The purposes of this study were to determine whether antigen is excreted by patients with Legionnaires disease early enough after the onset of symptoms to be useful for making therapeutic decisions and whether antigen excretion ends when successful treatment is concluded. Specific antigen was detected in the urine of 14 (88%) of 16 patients with Legionnaires disease during days 1 to 3 of symptoms, 33 (80%) of 41 patients during days 4 to 7, 25 (89%) of 28 patients during days 8 to 14, and 11 of 11 patients after day 14, by solid-phase immunoassays for serogroup 1 Legionella pneumophila antigen. Antigen excretion persisted for 42 days or longer after the onset of treatment in at least 15 patients. The longest documented duration of excretion was 326 days. We conclude that antigen can be detected approximately as often early after symptoms begin as later, allowing meaningful therapeutic decisions to be made, but that prolonged antigen excretion may negate the diagnostic value of urinary antigen detection for relapsing or recurrent L. pneumophila pneumonia.
Collapse
|