1
|
Zupan Mežnar A, Mrak M, Mullens W, Štublar J, Ivanovski M, Žižek D. AV-optimized conduction system pacing for treatment of AV dromotropathy: A randomized, cross-over study. J Cardiovasc Electrophysiol 2024; 35:1340-1350. [PMID: 38686618 DOI: 10.1111/jce.16268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 02/04/2024] [Accepted: 03/19/2024] [Indexed: 05/02/2024]
Abstract
BACKGROUND Severe first-degree atrioventricular (AV) block may produce symptoms similar to heart failure due to AV dyssynchrony, a syndrome termed AV dromotropathy. According to guidelines, it should be considered for permanent pacemaker implantation, yet evidence supporting this treatment is scarce. OBJECTIVES This study aimed to determine the impact of AV-optimized conduction system pacing (CSP) in patients with symptomatic severe first-degree AV block and echocardiographic signs of AV dyssynchrony. METHODS Patients with symptomatic first-degree AV block (PR > 250 ms), preserved left ventricular ejection fraction, narrow QRS, and AV dyssynchrony were included in the study. In a single-blind cross-over design, patients were randomized to AV sequential CSP or backup VVI pacing with a base rate of 40 bpm. We compared exercise capacity, echocardiographic parameters, and symptom occurrence at the end of 3 months of each period. RESULTS Fourteen patients completed the study. During the AV-optimized CSP compared to the backup pacing period, patients achieved a higher workload on exercise test (147.2 ± 50.9 vs. 140.7 ± 55.8 W; p = .032), with a trend towards higher peak VO2 (23.3 ± 7.1 vs. 22.8 ± 7.1 mL/min/kg; p = .224), and higher left ventricular stroke volume (LVSV 74.5 ± 13.8 vs. 66.4 ± 12.5 mL; p < .001). Symptomatic improvement was recorded, with fewer patients reporting general tiredness and 71% of patients preferring the AV-optimized CSP (p = .008). CONCLUSIONS AV-optimized CSP could improve symptoms, exercise capacity and LVSV in patients with severe first-degree AV block.
Collapse
Affiliation(s)
- Anja Zupan Mežnar
- Department of Cardiology, University Medical Center Ljubljana, Ljubljana, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Miha Mrak
- Department of Cardiology, University Medical Center Ljubljana, Ljubljana, Slovenia
| | - Wilfried Mullens
- Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium
- Faculty of Medicine and Life Sciences, University Hasselt, Hasselt, Belgium
| | - Jernej Štublar
- Department of Cardiology, University Medical Center Ljubljana, Ljubljana, Slovenia
- Department of Cardiovascular Surgery, University Medical Center Ljubljana, Ljubljana, Slovenia
| | - Maja Ivanovski
- Department of Cardiology, University Medical Center Ljubljana, Ljubljana, Slovenia
| | - David Žižek
- Department of Cardiology, University Medical Center Ljubljana, Ljubljana, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
2
|
Compier MG, Tops LF, Braun J, Zeppenfeld K, Klautz RJ, Schalij MJ, Trines SA. Limited left atrial surgical ablation effectively treats atrial fibrillation but decreases left atrial function. Europace 2017; 19:560-567. [PMID: 28431066 DOI: 10.1093/europace/euw106] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Accepted: 03/19/2016] [Indexed: 11/15/2022] Open
Abstract
AIMS Limited left atrial (LA) surgical ablation with bipolar radiofrequency is considered to be an effective procedure for treatment of atrial fibrillation (AF). We studied whether limited LA surgical ablation concomitant to cardiac surgery is able to maintain LA function. METHODS AND RESULTS Thirty-six consecutive patients (age 66 ± 12 years, 53% male, 78% persistent AF) scheduled for valve surgery and/or coronary revascularization and concomitant LA surgical ablation were included. Epicardial pulmonary vein isolation (PVI) and additional endo-epicardial lines were performed using bipolar radiofrequency. An age- and gender-matched control group (n = 36, age 66 ± 9 years, 69% male, 81% paroxysmal AF) was selected from patients undergoing concomitant epicardial PVI only. Left atrial dimensions and function were assessed on two-dimensional echocardiography preoperatively and at 3- and 12-month follow-up. Sinus rhythm (SR) maintenance was 67% for limited LA ablation and 81% for PVI at 1-year follow-up (P = 0.18). Left atrial volume decreased from 72 ± 21 to 50 ± 14 mL (31%, P < 0.01) after limited LA ablation and from 65 ± 23 to 56 ± 20 mL (14%, P < 0.01) after PVI. Atrial transport function was restored in 54% of patients in SR after limited LA ablation compared with 100% of patients in SR after PVI. Atrial strain and contraction parameters (LA ejection fraction, A-wave velocity, reservoir function, and strain rate) significantly decreased after limited LA ablation. After PVI, strain and contraction parameters remained unchanged. CONCLUSION Even limited LA ablation decreased LA volume, contraction, transport function, and compliance, indicating both reverse remodelling combined with significant functional deterioration. In contrast, surgical PVI decreased LA volume while function remained unchanged.
Collapse
Affiliation(s)
- Marieke G Compier
- Department of Cardiology, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands
| | - Laurens F Tops
- Department of Cardiology, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands
| | - Jerry Braun
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Katja Zeppenfeld
- Department of Cardiology, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands
| | - Robert J Klautz
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Martin J Schalij
- Department of Cardiology, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands
| | - Serge A Trines
- Department of Cardiology, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands
| |
Collapse
|
3
|
Anand NK, Maguire DP. Anesthetic Implications for Patients with Rate-Responsive Pacemakers. Semin Cardiothorac Vasc Anesth 2016; 9:251-9. [PMID: 16151557 DOI: 10.1177/108925320500900307] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
One hundred thousand adults and children in the United States receive pacemakers each year, of which 85% are rateresponsive pacemakers (RRPs). Recent advances in the fields of computer programming and computer chip technology have led to the myriad development of RRPs, which contain sensors that automatically adjust the pacing rate to match the physiologic changes that occur during physical exertion. Because patients with RRPs may experience heart rate changes in the operating room due to “normal” sensor function, anesthesiologists must be aware of the new developments in RRP sensor technology to properly manage these patients. Increases in respiratory rate and tidal volume as well as the use of electrocautery have been reported to accelerate the paced rate of pacemakers with minute ventilation sensors. Likewise, patient movement and saws that produce vibrations can accelerate the paced rate of patients with piezoelectric crystal sensors. This paper discusses the history of pacemaker development, reviews the currently used RRP sensors, and recommends procedures for the perioperative management of these patients. Knowledge of sensor type and factors that stimulate them will help the anesthesiologist understand the cause of these changes so that he will be able to manage clinically significant hemodynamic changes due to RRP sensor activation.
Collapse
Affiliation(s)
- Neil K Anand
- Department of Anesthesiology, Thomas Jefferson University, Philadelphia, PA 19107-5092, USA
| | | |
Collapse
|
4
|
Sayed SA, Katewa A, Srivastava V, Jana S, Patwardhan AM. Modified radial v/s biatrial maze for atrial fibrillation in rheumatic valvular heart surgery. Indian Heart J 2014; 66:510-6. [PMID: 25443604 DOI: 10.1016/j.ihj.2014.05.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2013] [Revised: 03/30/2014] [Accepted: 05/13/2014] [Indexed: 10/25/2022] Open
Abstract
BACKGROUND Atrial fibrillation (AF) is commonest sustained atrial arrhythmia producing high morbidity. Although Cox's Maze III procedure cures AF in majority, reduced atrial transport function (ATF) is a concern. Radial approach with ablation lines radial from sinus node towards atrioventricular annulii and parallel to atrial coronary arteries, has shown better ATF. METHODS Single blind open randomized prospective study of 80 patients was undertaken in two groups (40 each) of modified Cox's maze III and modified radial approach, to evaluate conversion to normal sinus rhythm (NSR) and ATF. Patients undergoing surgery for rheumatic valvular heart disease with continuous AF were prospectively randomized. Ablation lines were created with radiofrequency (RF) bipolar coagulation with cryoablation for the isthmal lesions and coronary sinus. Results were compared at 6 months and ATF was evaluated by atrial filling fraction (AFF) and A/E ratio on echocardiography. RESULTS The rate of conversion to NSR in both groups was statistically insignificant by Fisher's exact test (p > 0.05). ATF was better in modified radial approach compared to modified Cox's Maze III (A/E compared by unpaired t test:0.52 ± 0.08 v/s 0.36 ± 0.10; p < 0.05. AFF compared using Mann Whitney U test: median AFF for radial group was 23 v/s 20 for biatrial group; p < 0.05). DISCUSSION In patients with AF undergoing rheumatic valvular surgery, radiofrequency radial approach is as effective as modified Cox's maze III for conversion to NSR with better atrial transport function.
Collapse
Affiliation(s)
- Sajid A Sayed
- King Edward Memorial Hospital and Seth Gordhandas Sunderdas Medical College, Mumbai, India; Sr. Registrar, Dept. of CVTS, J. N. Med. College, Sawangi, Wardha (M), India.
| | - Ashish Katewa
- King Edward Memorial Hospital and Seth Gordhandas Sunderdas Medical College, Mumbai, India; Sr. Registrar, Dept. of CVTS, J. N. Med. College, Sawangi, Wardha (M), India
| | - Vivek Srivastava
- King Edward Memorial Hospital and Seth Gordhandas Sunderdas Medical College, Mumbai, India; Sr. Registrar, Dept. of CVTS, J. N. Med. College, Sawangi, Wardha (M), India
| | - Sujit Jana
- King Edward Memorial Hospital and Seth Gordhandas Sunderdas Medical College, Mumbai, India; Assistant Professor, Dept. of CVTS, J. N. Med. College, Sawangi, Wardha (M), India
| | - Anil M Patwardhan
- King Edward Memorial Hospital and Seth Gordhandas Sunderdas Medical College, Mumbai, India; Former Professor and Head, Dept. of CVTS, J. N. Med. College, Sawangi, Wardha (M), India; Professor, CVTS, J. N. Med. College, Sawangi, Wardha (M), India
| |
Collapse
|
5
|
Zakeri R, Borlaug BA, McNulty SE, Mohammed SF, Lewis GD, Semigran MJ, Deswal A, LeWinter M, Hernandez AF, Braunwald E, Redfield MM. Impact of atrial fibrillation on exercise capacity in heart failure with preserved ejection fraction: a RELAX trial ancillary study. Circ Heart Fail 2013; 7:123-30. [PMID: 24162898 DOI: 10.1161/circheartfailure.113.000568] [Citation(s) in RCA: 110] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
BACKGROUND Atrial fibrillation (AF) is common among patients with heart failure and preserved ejection fraction (HFpEF), but its clinical profile and impact on exercise capacity remain unclear. RELAX (Phosphodiesterase-5 Inhibition to Improve Clinical Status and Exercise Capacity in HFpEF) was a multicenter randomized trial testing the impact of sildenafil on peak VO2 in stable outpatients with chronic HFpEF. We sought to compare clinical features and exercise capacity among patients with HFpEF who were in sinus rhythm (SR) or AF. METHODS AND RESULTS RELAX enrolled 216 patients with HFpEF, of whom 79 (37%) were in AF, 124 (57%) in SR, and 13 in other rhythms. Participants underwent baseline cardiopulmonary exercise testing, echocardiogram, biomarker assessment, and rhythm status assessment before randomization. Patients with AF were older than those in SR but had similar symptom severity, comorbidities, and renal function. β-blocker use and chronotropic indices were also similar. Despite comparable left ventricular size and mass, AF was associated with worse systolic (lower EF, stroke volume, and cardiac index) and diastolic (shorter deceleration time and larger left atria) function compared with SR. Pulmonary artery systolic pressure was higher in AF. Patients with AF had higher N-terminal pro-B-type natriuretic peptide, aldosterone, endothelin-1, troponin I, and C-telopeptide for type I collagen levels, suggesting more severe neurohumoral activation, myocyte necrosis, and fibrosis. Peak VO2 was lower in AF, even after adjustment for age, sex, and chronotropic response, and VE/VCO2 was higher. CONCLUSIONS AF identifies an HFpEF cohort with more advanced disease and significantly reduced exercise capacity. These data suggest that evaluation of the impact of different rate or rhythm control strategies on exercise tolerance in patients with HFpEF and AF is warranted. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00763867.
Collapse
|
6
|
Marchandise S, Scavee C, le Polain de Waroux JB, de Meester C, Vanoverschelde JL, Debbas N. Long-term follow-up of DDD and VDD pacing: a prospective non-randomized single-centre comparison of patients with symptomatic atrioventricular block. Europace 2011; 14:496-501. [DOI: 10.1093/europace/eur345] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
7
|
Kaszala K, Ellenbogen KA. Device sensing: sensors and algorithms for pacemakers and implantable cardioverter defibrillators. Circulation 2010; 122:1328-40. [PMID: 20876446 DOI: 10.1161/circulationaha.109.919704] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Károly Kaszala
- VCU School of Medicine, PO Box 980053, Richmond, VA 23298-0053, USA
| | | |
Collapse
|
8
|
OUALI SANA, NEFFETI ELYES, GHOUL KARIMA, HAMMAS SAMI, KACEM SLIM, GRIBAA RIM, REMEDI FAHMI, BOUGHZELA ESSIA. DDD versus VVIR Pacing in Patients, Ages 70 and Over, with Complete Heart Block. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2009; 33:583-9. [DOI: 10.1111/j.1540-8159.2009.02636.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
9
|
Ståhlberg M, Damgaard M, Norsk P, Gabrielsen A, Sahlén A, Linde C, Braunschweig F. Cardiac output response to changes of the atrioventricular delay in different body positions and during exercise in patients receiving cardiac resynchronization therapy. Europace 2009; 11:1160-7. [PMID: 19578177 DOI: 10.1093/europace/eup173] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Marcus Ståhlberg
- Department of Cardiology, Karolinska Institutet, Karolinska University Hospital, S-17176 Stockholm, Sweden.
| | | | | | | | | | | | | |
Collapse
|
10
|
|
11
|
LAU CHUPAK, LEUNG WINGHUNG, WONG CHEUKKIT, CHENG CHUNHO, TAI YAUTING. Adaptive Rate Pacing at Submaximal Exercise: The Importance of the Programmed Upper Rate. ACTA ACUST UNITED AC 2008. [DOI: 10.1111/j.1540-8167.1989.tb01564.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
12
|
|
13
|
Ishii Y, Nitta T. Atrial fibrillation surgery for patients with rheumatic valve disease. J Interv Card Electrophysiol 2007; 20:109-12. [DOI: 10.1007/s10840-007-9179-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
14
|
|
15
|
Arena R, Myers J, Williams MA, Gulati M, Kligfield P, Balady GJ, Collins E, Fletcher G. Assessment of Functional Capacity in Clinical and Research Settings. Circulation 2007; 116:329-43. [PMID: 17576872 DOI: 10.1161/circulationaha.106.184461] [Citation(s) in RCA: 375] [Impact Index Per Article: 22.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
Zupan I, Lipar L, Zizek D, Boute W, Vidmar M, Gabrijelcic T, Rakovec P, Brecelj A. Retrospective analysis of mode survival, reliability of atrial sensing and incidence of atrial tachyarrhythmias in 307 single-lead VDD pacemaker patients. ACTA ACUST UNITED AC 2006; 8:855-8. [PMID: 16891329 DOI: 10.1093/europace/eul091] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
AIMS The aim of this retrospective analysis was to investigate VDD mode survival, development of atrial tachyarrhythmias (AT), and long-term atrial sensing performance of VDD pacing systems. METHODS AND RESULTS We implanted single-lead VDD pacemakers in patients with isolated atrioventricular block and performed a retrospective analysis of 307 patients who had their devices implanted between May 1994 and September 2001. In 39 patients (12.7%), the pacing mode had to be reprogrammed to a single-chamber ventricular pacing mode, mostly due to permanent AT. In 16 of these patients, the atrial sensing safety margin was less than 150%. The atrial sensing safety margin was insufficient, i.e. less than 100% in only seven patients. Although only 12 (3.9%) of the patients had a history of paroxysmal AT at the time of pacemaker implantation, 200 (65%) patients presented with AT during follow-up. The mean AT burden at the last follow-up was 2.5%. CONCLUSION These data illustrate that single-lead VDD pacemakers can be applied without serious complications in a highly selected group of patients. Our main concern is the development of AT in a large part of our population. Over a 10-year period, two thirds of our patients presented with AT.
Collapse
Affiliation(s)
- Igor Zupan
- Department of Cardiology, University Medical Centre Ljubljana, Zaloska 7, 1000 Ljubljana, Slovenia.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Ferro A, Duilio C, Santomauro M, Salvatore M, Cuocolo A. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function. Eur J Nucl Med Mol Imaging 2005; 32:1075-80. [PMID: 15891919 DOI: 10.1007/s00259-005-1790-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2004] [Accepted: 02/04/2005] [Indexed: 11/24/2022]
Abstract
PURPOSE Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. METHODS Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction >or=50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. RESULTS In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). CONCLUSION Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function.
Collapse
Affiliation(s)
- Adele Ferro
- Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, University Federico II, Naples, Italy
| | | | | | | | | |
Collapse
|
18
|
Drago F, Silvetti MS, De Santis A, Grutter G, Calcagnini G, Censi F, Bartolini P, Barbaro V. Beat‐to‐Beat Heart Rate Adaptation in Pediatric and Late Adolescent Patients with Closed Loop Rate‐Responsive Pacemakers. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2005; 28:212-8. [PMID: 15733181 DOI: 10.1111/j.1540-8159.2005.09431.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The aim of this study was to evaluate the efficacy of physiological rate-responsive pacemakers (Closed Loop Stimulation--CLS) to pace pediatric and late adolescent patients undergoing rest, mental, standing, and exercise testing. Dual-chamber pacemaker is increasingly indicated for young patients. A new physiological pacing mode based on the indirect measure of ventricular contractility (CLS), has shown interesting results in adults, while no data on pediatric patients are available. RR intervals and beat-to-beat systolic and diastolic pressures were monitored in 12 pediatric patients (6 males, mean age 17 years [12-22 years]) who had a transvenous implant of Inos2+-CLS dual-chamber pacemaker (Biotronik GmbH, Berlin, Germany) and endocardial leads. All the patients showed correct electrical parameters at the implant and during the follow-ups. Paced RR intervals decreased significantly (F = 7.28, P = 0.01) from 0.85 +/- 0.08 seconds (rest) to 0.73 +/- 0.10 seconds (mental) and to 0.75 +/- 0.010 seconds (standing); systolic/diastolic pressure was significantly higher (F = 12.2, P = 0.002/F = 13.6, P = 0.001) in mental (134.4 +/- 19.9/74.4 +/- 8.1 mmHg) with respect to rest (115.1 +/- 18.3/61.0 +/- 6.1 mmHg), and standing (118.7 +/- 23.9/67.3 +/- 0.1 mmHg). During exercise the paced RR interval showed significant decrease of about 35% from baseline to maximum load (F = 24.90, P = 0.001) and systolic pressure increased significantly (F = 4.91, P = 0.019) by about 34% from baseline to maximum load. The comparison between paced and spontaneous rates showed very similar values and trend. In addition, CLS mode does not seem to overrun the spontaneous heart activity, when present. This is a study to evaluate CLS pacing in pediatric and late adolescent patients. The study shows that CLS pacing responds to both physical and non-physical stressors, providing physiological pacing rates, as previously observed in adults.
Collapse
|
19
|
Dretzke J, Toff WD, Lip GYH, Raftery J, Fry-Smith A, Taylor R. Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block. Cochrane Database Syst Rev 2004; 2004:CD003710. [PMID: 15106214 PMCID: PMC8095057 DOI: 10.1002/14651858.cd003710.pub2] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND Dual chamber pacing or single chamber atrial pacing ('physiologic' pacing) is believed to have an advantage over single chamber ventricular pacing in that it resembles cardiac physiology more closely by maintaining atrioventricular (AV) synchrony and dominance of the sinus node, which in turn may reduce cardiovascular morbidity and mortality thus contributing to patient survival and quality of life. However, a significant proportion of pacemakers currently implanted are single chamber ventricular pacemakers. OBJECTIVES The objective of this review was to assess the short- and long-term clinical effectiveness of dual chamber pacemakers compared to single chamber ventricular pacemakers in adults with AV block, sick sinus syndrome or both. An additional objective was to assess separately any potential differences in effectiveness between dual chamber pacing and single chamber atrial pacing. The clinical effectiveness of single chamber atrial pacing versus single chamber ventricular pacing was not examined. SEARCH STRATEGY The Cochrane Controlled Trials Register (The Cochrane Library Issue 3, 2002), MEDLINE (1966 to 2002), EMBASE (1980 to 2002) and the Science Citation Index (1980 to 2002) were searched on 19th August 2002. Citation lists and web sites were checked and researchers in the field contacted. SELECTION CRITERIA Parallel group or crossover randomised controlled trials of at least 48 hours duration comparing dual chamber pacing and single chamber ventricular pacing, and investigating cardiovascular morbidity, mortality, patient related quality of life, exercise capacity and complication rates. DATA COLLECTION AND ANALYSIS Data was extracted onto pre-piloted data extraction forms. Quality assessment was undertaken using a checklist, with a sub-sample of quality data independently extracted by a second reviewer. Where appropriate data was available, meta-analysis was performed. Where meta-analysis was not possible, the number of studies showing a positive, neutral or negative direction of effect and statistical significance were simply counted. MAIN RESULTS Five parallel and 26 crossover randomised controlled trials were identified. The quality of reporting was found to be poor. Pooled data from parallel studies shows a statistically non-significant preference for physiologic pacing (primarily dual chamber pacing) for the prevention of stroke, heart failure and mortality, and a statistically significant beneficial effect regarding the prevention of atrial fibrillation (odds ratio (OR) 0.79, 95% CI 0.68 to 0.93). Both parallel and crossover studies favour dual chamber pacing with regard to pacemaker syndrome (parallel: Peto OR 0.11, 95% CI 0.08 to 0.14; crossover: standardised mean difference (SMD) -0.74, 95% CI - 0.95 to -0.52). Pooled data from crossover studies shows a statistically significant trend towards dual chamber pacing being more favourable in terms of exercise capacity (SMD -0.24, 95% CI -0.03 to -0.45). No individual studies reported a significantly more favourable outcome with single chamber ventricular pacing. REVIEWERS' CONCLUSIONS This review shows a trend towards greater effectiveness with dual chamber pacing compared to single chamber ventricular pacing, which supports the current British Pacing and Electrophysiology Group's Guidelines regarding atrioventricular block. Additional randomised controlled trial evidence from ongoing trials in this area will further inform the debate.
Collapse
Affiliation(s)
- J Dretzke
- Department of Public Health & Epidemiology, University of Birmingham, Edgbaston, Birmingham, UK, B15 2TT
| | | | | | | | | | | |
Collapse
|
20
|
Ishii Y, Nitta T, Fujii M, Ogasawara H, Iwaki H, Ohkubo N, Tanaka S. Serial change in the atrial transport function after the radial incision approach. Ann Thorac Surg 2001; 71:572-6. [PMID: 11235708 DOI: 10.1016/s0003-4975(00)02520-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND The left atrial transport function recovers slowly over several months after the maze procedure (Maze), but remains at a low level even during the long-term postoperative period. Because the Maze leaves an insufficient left atrial transport function, patients may still be prone to thromboembolism after the Maze. The radial incision approach (Radial) has been shown to preserve greater atrial transport function than does the Maze in the early postoperative period. METHODS To examine the serial change in the atrial transport function after the Radial, out of 32 patients who underwent the Radial, 15 patients were assessed by transthoracic Doppler echocardiography 1, 3, 6, and 12 months after surgery. The atrial filling fraction and peak A/E velocity ratio were determined from the flow-velocity spectra across the mitral and tricuspid valves. The incidence of thromboembolic events was examined in 21 patients who were followed for more than 3 months after the Radial. The data were compared with data obtained from 13 patients after (41 +/- 6 months) the Maze III procedure. RESULTS The left atrial transport function after the Radial increased within 3 months to a significantly greater level than did that after the Maze in the longterm. The atrial filling fraction was 28.2% +/- 7.9% at 3 months after the Radial and 15.1% +/- 4.0% at 41 months after the Maze (p < 0.01). The peak A/E ratio was 0.52 +/- 0.18 at 3 months after the Radial and 0.25 +/- 0.07 at 41 months after the Maze (p < 0.01). This increased atrial transport function was maintained for an extended period after the Radial. There were no thromboembolic events in any of the patients after the Radial or Maze, irrespective of postoperative anticoagulant therapy. CONCLUSIONS The Radial approach prevents thromboembolism by restoring sufficient atrial transport function more effectively and faster than does the Maze.
Collapse
Affiliation(s)
- Y Ishii
- Department of Cardiothoracic Surgery, Nippon Medical School, Tokyo, Japan
| | | | | | | | | | | | | |
Collapse
|
21
|
Fleg JL, Piña IL, Balady GJ, Chaitman BR, Fletcher B, Lavie C, Limacher MC, Stein RA, Williams M, Bazzarre T. Assessment of functional capacity in clinical and research applications: An advisory from the Committee on Exercise, Rehabilitation, and Prevention, Council on Clinical Cardiology, American Heart Association. Circulation 2000; 102:1591-7. [PMID: 11004153 DOI: 10.1161/01.cir.102.13.1591] [Citation(s) in RCA: 199] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
22
|
Ijiri H, Komori S, Kohno I, Sano S, Yin D, Takusagawa M, Iida T, Yamamoto K, Osada M, Sawanobori T, Ishihara T, Umetani K, Tamura K. Improvement of exercise tolerance by single lead VDD pacemaker: evaluation using cardiopulmonary exercise test. Pacing Clin Electrophysiol 2000; 23:1336-42. [PMID: 11025888 DOI: 10.1111/j.1540-8159.2000.tb00960.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We used a cardiopulmonary test to assess the physiological benefit of single lead VDD pacing in ten patients (six men, four women; aged 32-84 years, mean 69 years) with atrioventricular block. Maximal symptom-limited treadmill exercise test using a ramp protocol was performed under VDD and VVIR or VVI pacing (VVI) in random sequence. The pacemaker was then programmed to the VDD mode, and Holter ECG was recorded in nine patients. Compared with findings during the VVI, the VDD mode had a greater chronotropic response (mean maximal heart rate, VDD 106 +/- 17 beats/min vs VVI 79 +/- 19 beats/min, P = 0.03), and was associated with prolongation of exercise duration (VDD 11.2 +/- 2.9 minute vs VVI 10.5 +/- 3.1 minute; P = 0.01), and the onset of anaerobic threshold at a higher oxygen uptake (VDD 12.4 +/- 3.4 mL/min per kilogram vs VVI 10.0 +/- 2.1 mL/min per kilogram; P < 0.01). Atrial sensing was recognized in almost all normal sinus P waves for all cases examined using Holter ECG. Thus, chronotropic response during exercise by VDD pacemaker improved exercise tolerance, indicating that a VDD pacemaker might be useful for patients requiring physical activity.
Collapse
Affiliation(s)
- H Ijiri
- Second Department of Medicine, Yamanashi Medical University, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Rickli H, Brunner-La Rocca HP, Maccarter DJ, Duru F, Candinas R. Importance of AV synchronous pacing during low intensity exercise evaluated by oxygen kinetics. Pacing Clin Electrophysiol 2000; 23:174-9. [PMID: 10709225 DOI: 10.1111/j.1540-8159.2000.tb00798.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
It has been shown that dual chamber pacing with preservation of AV synchrony (DDD) is superior to fixed rate ventricular (VVI) or rate responsive ventricular (VVIR) pacing modes, as evaluated by ventilatory response to exercise. Previous studies have focused on the benefits of maintained AV synchrony at maximal exercise. However, there are limited data comparing O2 kinetics in different pacing modes during low intensity exercise, representing the majority of daily activities. This study aimed to provide an evaluation of different pacing modes using O2 kinetics during low intensity exercise. Nineteen patients (age 61 +/- 18 years) with complete AV block underwent low intensity treadmill exercise (35 W) with simultaneous evaluation of symptoms and O2 kinetics in three pacing modes. The first test was performed in DDD mode followed by a second test in VVIR mode with a programmed heart rate corresponding to the sinus rate during the first test. After 6 minutes of each test, the mode was switched from DDD to VVIR and vice versa. The third test was performed in VVI mode at 70 beats/min. O2 kinetics were defined as O2 deficit (time [rest to steady state] x delta VO2-sigma VO2 [rest to steady state]) and mean response time (MRT) of oxygen consumption (O2 deficit/delta VO2). The O2 deficit was 551 +/- 134 mL in DDD pacing, 634 +/- 139 mL in VVIR pacing, and 648 +/- 179 mL in VVI pacing (P = 0.001). MRT was 49 +/- 7.8 seconds in DDD pacing, 54.7 +/- 9.5 seconds in VVIR pacing, and 57.4 +/- 11.0 seconds in VVI pacing (P = 0.002). Ten (53%) patients developed symptoms during switch from DDD to VVIR mode whereas the switch from VVIR to DDD mode was not perceived by any patient (P < 0.001). In conclusion, our study shows an impact of AV synchronous pacing and heart rate adaptation on O2 kinetics during low intensity exercise that correspond to casual daily life activities. Our observations may have clinical implications for the management of patients with complete AV block.
Collapse
Affiliation(s)
- H Rickli
- Division of Cardiology, University Hospital Zurich, Switzerland.
| | | | | | | | | |
Collapse
|
24
|
Celiker A, Ceviz N, Alehan D, Lenk MK, Ozme S. Comparison of normal sinus rhythm and pacing rate in children with minute ventilation single chamber rate adaptive permanent pacemakers. Pacing Clin Electrophysiol 1998; 21:2100-4. [PMID: 9826863 DOI: 10.1111/j.1540-8159.1998.tb01130.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Rate adaptive pacemakers are used to achieve a better cardiac performance during exercise by increasing the heart rate and cardiac output. The ideal rate adaptive sensor should be able to mimic sinus node modulation under various degrees of exercise and other metabolic needs. Minute ventilation sensing has proven to be one of the most accurate sensor systems. In this study, alterations in sinus rhythm and pacing rates during daily life conditions in 11 children (median age 11 years, range 6-14 years) with minute ventilation single chamber pacemakers were investigated. Correlation of sinus rhythm with pacing rates was assessed. ECG records were obtained from 24-hour Holter monitoring. Average rates of five consecutive P waves and pace waves were determined every half hour. The average of the two values was then used to determine hourly rates. Correlation coefficients between the sinus rhythm and pacing rates were calculated. In nine patients, pacing rates correlated well to sinus rhythm (range 0.6793-0.9558, P < 0.001 and P < 0.05), whereas in two cases correlation was not sufficient (P > 0.05). Most of the patients, in whom rate response factor (RRF) measurements during peak exercise by treadmill with chronotropic assessment exercise protocol were performed and pacemakers were programmed to these parameters, had more appropriate ventricular rates compared to spontaneous sinus rates. In these patients mean RRF value was 15.3 +/- 2.7 (range 12-20, median 15). This study shows that during daily activities minute ventilation rate adaptive pacemakers can achieve pacing rates well correlated to sinus rhythm that reflects the physiological heart rate in children.
Collapse
Affiliation(s)
- A Celiker
- Department of Pediatrics, Hacettepe University, Faculty of Medicine, Ankara, Turkey.
| | | | | | | | | |
Collapse
|
25
|
Pardaens K, Van Cleemput J, Vanhaecke J, Fagard RH. Atrial fibrillation is associated with a lower exercise capacity in male chronic heart failure patients. HEART (BRITISH CARDIAC SOCIETY) 1997; 78:564-8. [PMID: 9470871 PMCID: PMC1892336 DOI: 10.1136/hrt.78.6.564] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE To study the influence of atrial fibrillation on peak oxygen uptake (peak VO2) in chronic heart failure. An unfavourable effect of atrial fibrillation has been shown in several patient populations, but the results have not been consistent in chronic heart failure. METHODS Data were analysed from male heart transplant candidates who were able to perform graded bicycle ergometry until exhaustion with respiratory gas analysis and measurement of heart rate. Patients in atrial fibrillation (n = 18) were compared with patients in sinus rhythm (n = 93). RESULTS Age, weight, height, and aetiology of chronic heart failure did not differ significantly between the two groups. Cardiac catheterisation at supine rest showed that heart rate was comparable, but that stroke volume and cardiac output were lower (p < 0.05) in atrial fibrillation. Systolic and diastolic left ventricular function, assessed by radionuclide angiography at rest, were not significantly different. Peak VO2 (mean (SD): 13.8 (3.6) v 17.1 (5.6) ml/kg/min; p < 0.01) and peak work load (78 (27) v 98 (36) W; p < 0.05) were lower in the patients with atrial fibrillation, though respiratory gas exchange ratio and Borg score were similar in the two groups. Patients with atrial fibrillation had a higher heart rate sitting at rest before exercise (93 (16) v 84 (16) beats/min) and at peak effort (156 (23) v 140 (25) beats/min) (p < 0.05). CONCLUSIONS Atrial fibrillation is associated with a 20% lower peak VO2 in patients with chronic heart failure, suggesting that preserved atrial contraction or a regular rhythm, or both, are critical to maintain cardiac output and exercise performance.
Collapse
Affiliation(s)
- K Pardaens
- Department of Molecular and Cardiovascular Research, Faculty of Medicine, University of Leuven, Belgium
| | | | | | | |
Collapse
|
26
|
Hasegawa A, Hatori M, Amano M, Iijima T, Adachi H, Yamaguchi E, Fukuda T, Murata K, Nagai R. Adequacy of pacing rate during exercise in rate responsive ventricular pacing. Pacing Clin Electrophysiol 1997; 20:307-12. [PMID: 9058868 DOI: 10.1111/j.1540-8159.1997.tb06175.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Our objective was to determine the adequate pacing rate during exercise in ventricular pacing by measuring exercise capacity, cardiac output, and sinus node activity. Eighteen patients with complete AV block and an implanted pacemaker underwent cardiopulmonary exercise tests under three randomized pacing rates: fixed rate pacing (VVI) at 60 beats/min and ventricular rate-responsive pacing (VVIR) programmed to attain a heart rate of about 110 beats/min or 130 beats/min (VVIR 110 and VVIR 130, respectively) at the end of exercise. Compared with VVI and VVIR 130, VVIR 110 was associated with an increased peak oxygen uptake (VVIR 110: 20.3 +/- 4.5 VVI: 16.9 +/- 3.1; P < 0.01; and VVIR 130: 19.0 +/- 4.1 mL/min per kg, respectively; P < 0.05 and a higher oxygen uptake at anaerobic threshold (15.3 +/- 2.7, 12.7 +/- 1.9; P < 0.01, and 14.6 +/- 2.6 mL/min per kg; P < 0.05). The atrial rate during exercise expressed as a percentage of the expected maximal heart rate was lower in VVIR 110 than in VVI or VVIR 130 (VVIR 110: 75.9% +/- 14.6% vs VVI: 90.6% +/- 12.8%; P < 0.01; VVIR 110 vs 130: 89.1% +/- 23.1% P < 0.05). There was no significant in cardiac output at peak exercise between VVIR 110 and VVIR 130. We conclude that a pacing rate for submaximal exercise of 110 beats/min may be preferable to that of 130 beats/min in respect to exercise capacity and sympathetic nerve activity.
Collapse
Affiliation(s)
- A Hasegawa
- Second Department of Internal Medicine, Gunma University School of Medicine, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Deharo JC, Badier M, Thirion X, Ritter P, Provenier F, Graux P, Guillot C, Mugica J, Jordaens L, Djiane P. A randomized, single-blind crossover comparison of the effects of chronic DDD and dual sensor VVIR pacing mode on quality-of-life and cardiopulmonary performance in complete heart block. Pacing Clin Electrophysiol 1996; 19:1320-6. [PMID: 8880795 DOI: 10.1111/j.1540-8159.1996.tb04210.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The aim of this study was to compare DDD and dual sensor VVIR (activity and QT) pacing modes in complete AV block (CAVB). Eighteen patients (14 men and 4 women, aged 70 +/- 6.5 years) implanted with a dual chamber, dual sensor pacemaker for CAVB with normal sinus node chronotropic function were studied. A quality-of-life and cardiovascular symptom questionnaire, and a treadmill exercise test were completed after a period of VVIR and a period of DDD pacing, each lasting 1 month. Overall quality-of-life and cardiovascular symptoms did not significantly differ, though three patients felt discomfort during VVIR mode. There was no significant statistical difference in cardiopulmonary parameters. DDD and VVIR modes yielded the following respective data: maximum heart rate = 105.7 +/- 21.8 beats/minute versus 107.6 +/- 21.6 beats/minute (NS); maximum workload = 60 +/- 33.4 W versus 59.3 +/- 37.8 W (NS); treadmill duration = 10.1 +/- 3.8 minute versus 10.1 +/- 3.6 minute (NS); oxygen consumption at anaerobic threshold = 14.6 +/- 4.1 mL/kg per minute versus 14.9 +/- 4.6 mL/kg per minute (NS); maximum minute ventilation = 49.6 +/- 9L/min versus 46 +/- 12 L/min (NS); and respiratory quotient = 1.08 +/- 0.15 versus 1.08 +/- 0.13 (NS). We conclude that, during a 1-month follow-up period, no difference was found between DDD and dual sensor VVIR (QT and activity) pacing modes in CAVB patients with regard to quality-of-life and cardiopulmonary performance, though a trend toward an increased sense of well being was noted with the DDD mode.
Collapse
Affiliation(s)
- J C Deharo
- Department of Cardiology, Hôpital Sainte-Marguerite, Marseille, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Soussou AI, Helmy MG, Guindy RR. Preimplantation echo Doppler evaluation of VVI versus DDD pacing. Echocardiography 1995; 12:335-49. [PMID: 10150780 DOI: 10.1111/j.1540-8175.1995.tb00556.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
UNLABELLED This study was carried out to select before permanent pacemaker implantation patients with complete atrioventricular block (CHB) who would benefit best from DDD pacing, and to determine the optimal atrioventricular delay (AVD) for each of those patients. This was achieved with the aid of Doppler echocardiography. The effect of different AVDs on both the systolic and diastolic function of the normal and failing heart was also delineated in this study. METHODS Thirty patients with CHB and normal sinoatrial function were selected, with no age or sex predilection. These patients were categorized into three equal groups: groups A, B, and C with normal left ventricular (LV) systolic and diastolic function, LV diastolic dysfunction, and LV systolic dysfunction, respectively. For each patient, systolic and diastolic function was calculated utilizing echo Doppler during CHB, temporary VDD pacing with different AVDs, and temporary VVI pacing with a rate matching that during VDD mode. Temporary VDD mode of pacing was performed utilizing a temporary bipolar ventricular lead for ventricular pacing and an esophageal lead for atrial sensing to trigger ventricular pacing. RESULTS Qualitatively the most obvious change in the pattern of LV filling as AVD is increased in the three groups, is the earlier occurrence of active atrial filling A wave due to progressive approximation of the ECG P wave toward the previous QRS. As the AV interval is increased, the following changes occur: (a) A wave occurs progressively earlier with superimposition onto the early filling E wave resulting in a progressive increase in its velocity (VA), its FVI, and its percent atrial contribution (%AC); (b) the three times diastolic filling time (DFT), mitral valve opening to Q wave (MVO-Q), and closure (Q-MVC) progressively shorten; (c) since DFT decreases, less passive filling occurs early during diastole, thus E.FVI decrease with longer AV intervals; (d) the ratios VE/VA and FVI E/A decrease subsequently to the previous described changes. Compared to CHB, percent ejection fraction (% EF) was not significantly changed during VVI pacing. Percent EF increased significantly during VDD in comparison to VVI pacing modes. Percent EF was highest at optimal AVD and decreased as this AVD increased or decreased. The cardiac output (CO) increment during VDD in comparison to VVI pacing modes differed much among the three groups. In group A, a 10.29% increase in CO was seen when comparing VDD pacing (with optimal AVD) with that of VII one; in group B, this increment was much greater and reached 29.48%; in group C it reached 23.68%.(ABSTRACT TRUNCATED AT 400 WORDS)
Collapse
|
29
|
McComb JM, Bexton RS. Permanent pacemakers and the elderly: concerns, costs and benefits. BRITISH HEART JOURNAL 1995; 74:9-10. [PMID: 7662464 PMCID: PMC483936 DOI: 10.1136/hrt.74.1.9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
30
|
Nowak B, Voigtländer T, Himmrich E, Liebrich A, Poschmann G, Epperlein S, Treese N, Meyer J. Cardiac output in single-lead VDD pacing versus rate-matched VVIR pacing. Am J Cardiol 1995; 75:904-7. [PMID: 7732998 DOI: 10.1016/s0002-9149(99)80684-5] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The importance of atrioventricular synchronous pacing compared with single-chamber rate-responsive pacing is still under discussion, especially for low-intensity workload representing daily life activities. We evaluated hemodynamics in single-lead VDD pacing versus VVIR pacing in 11 patients (8 men and 3 women, aged 58.6 +/- 13.8 years) with normal left ventricular function and a previously implanted single-lead VDDR pacemaker. A low-intensity steady-state treadmill test at 1 to 2.5 mph with a gradient of 2% to 4% was performed. Cardiac output was determined using a standard carbon dioxide rebreathing technique. Initially, the VDD mode was programmed, and after 5 minutes of exercise, cardiac output was measured in steady-state conditions. The pacemaker was then reprogrammed to the VVI mode at a rate 5 to 10 beats above the maximal atrial tracking rate to simulate rate-matched VVIR pacing (VVIRm). After 5 additional minutes of steady-state exercise, cardiac output was measured again. The maximal atrial rate in the VDD mode was 119 +/- 19 beats/min versus a programmed rate of 129 +/- 18 beats/min in the VVIRm mode. VDD pacing resulted in a significantly higher cardiac output than VVIRm pacing (10.6 +/- 1.9 vs 9.2 +/- 1.4 L/min; p < 0.002), with a mean difference of 1.6 +/- 1.2 L/min between the 2 modes. In the VDD mode, stroke volume (90.7 +/- 20.1 vs 71.6 +/- 13.0 ml; p < 0.001) and maximal oxygen uptake (1,183 +/- 264 vs 1,076 +/- 289 ml/min, p < 0.01) were also higher than in VVIRm.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- B Nowak
- II Medical Clinic, Johannes Gutenberg University, Mainz, Germany
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Frielingsdorf J, Dür P, Gerber AE, Vuilliomenet A, Bertel O. Physical work capacity with rate responsive ventricular pacing (VVIR) versus dual chamber pacing (DDD) in patients with normal and diminished left ventricular function. Int J Cardiol 1995; 49:239-48. [PMID: 7649670 DOI: 10.1016/0167-5273(95)02308-j] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
To determine the benefit of atrial contribution on work capacity in relation to left ventricular ejection fraction, we studied 17 patients (68 +/- 13 years) with dual chamber pacemakers (DDD) implanted for high degree atrioventricular (AV) block. In random order they were assigned to rate responsive ventricular (VVIR) and to atrial triggered ventricular (VDD) stimulation. Maximum oxygen uptake (max VO2), that correlates best with work capacity, was measured by spiroergometry at a respiratory quotient of 1.1 during treadmill exercise test. Left ventricular ejection fraction at rest was determined by radionuclide ventriculography during VDD-stimulation and an AV delay of 150 ms. There were no differences between these two pacing modes relating heart rate, blood pressure, minute ventilation, exercise duration and maximal work load. In eight patients with an ejection fraction > 50% (60 +/- 10%), but not in nine patients with an ejection fraction < 50% (41 +/- 10%), maximum oxygen uptake was significantly higher (P < 0.01) during atrial triggered ventricular pacing (1440 +/- 533 ml/min) compared with rate responsive ventricular pacing (1328 +/- 536 ml/min). Thus, rate responsive single chamber pacemakers largely enable the same work capacity as dual chamber pacemakers in patients with high degree AV block. Patients with normal left ventricular function may profit most from preserved AV synchrony as shown by the higher maximum oxygen uptake on exercise.
Collapse
Affiliation(s)
- J Frielingsdorf
- Cardiology Division, University Hospital, Zürich, Switzerland
| | | | | | | | | |
Collapse
|
32
|
Alt EU, Schlegl MJ, Matula MM. Intrinsic Heart Rate Response as a Predictor of Rate-Adaptive Pacing Benefit. Chest 1995; 107:925-30. [PMID: 7705155 DOI: 10.1378/chest.107.4.925] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
OBJECTIVE More than half of the pacemaker systems now being implanted can be rate adaptively paced. Our objective was to determine which patients benefit from rate-adaptive pacing in terms of improvement in maximum performance and aerobic capacity. METHODS Thirty patients with implanted accelerometer-driven, rate-adaptive pacemakers underwent a standardized, ergospirometrically and maximally symptoms = limited cardiopulmonary exercise (CPX) stress test with both rate-adaptive and fixed-rate stimulation in a randomized order. The patients were divided into three groups depending on the intrinsic heart rate achieved during maximum workload: group 1 achieved < or = 90 beats per minute (bpm), group 2 achieved 90 to < or = 110 bpm, and group 3 achieved > 110 bpm. RESULTS Group 1 demonstrated a significant increase (p < or = 0.01) in maximum oxygen uptake from 16.4 +/- 5.6 mL/kg/min with fixed-rate pacing to 23.2 +/- 11.1 mL/kg/min (+ 41.5%) with rate-adaptive pacing. At the anaerobic threshold, oxygen uptake significantly increased (p < or = 0.01) from 11.8 +/- 2.7 mL/kg/min to 15.7 +/- 5 mL/kg/min (+33.1%). Group 2 patients showed an increase in maximum oxygen uptake from 23.3 +/- 5.4 mL/kg/min to 25.3 +/- 4.9 mL/kg/min (+8.5%, p < or = 0.05) as well as an increase in oxygen uptake at the anaerobic threshold from 15.9 +/- 2.6 mL/kg/min to 18.1 +/- 2.9 mL/kg/min (+13.8%, p < or = 0.05) with rate-adaptive pacing. Group 3 demonstrated no significant difference between the two pacing methods (from 25.6 +/- 9.4 mL/kg/min to 25.9 +/- 9.3 mL/kg/min and from 15.8 +/- 5.5 mL/kg/min to 16.3 +/- 6 mL/kg/min). No difference in maximum oxygen uptake and in oxygen uptake at the anaerobic threshold was evident among the three groups when paced rate adaptively (not significant). CONCLUSION The second-generation, accelerometer controlled rate-adaptive pacemakers used in testing enabled a stress-oriented heart rate increase and an age- and gender-dependent adequate matching of maximum performance. The benefit from a rate-adaptive system to the patient increases as his or her chronotropic reserve limitation became more pronounced.
Collapse
Affiliation(s)
- E U Alt
- 1. Medizinische Klinik, Technische Universität München, Germany
| | | | | |
Collapse
|
33
|
Barrington WW, Windle JR, Easley AA, Rundlett R, Eisenger G. Clinical comparison of acute single to dual chamber pacing in chronotropically incompetent patients with left ventricular dysfunction. Pacing Clin Electrophysiol 1995; 18:433-40. [PMID: 7770363 DOI: 10.1111/j.1540-8159.1995.tb02542.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Dual chamber, rate responsive (DDDR) pacing is felt to be superior to ventricular, rate responsive (VVIR) pacing since it more closely mimics the normal electrical and hemodynamic activity of the heart. This reasoning has been used to justify the higher initial costs and increased complexity of dual chamber system. This study was designed to determine if objective criteria could be identified during acute testing justify implanting a dual chamber instead of a single chamber system in patients with left ventricular dysfunction. Eight patients with DDDR pacemakers (implanted for chronotropic incompetence) and left ventricular dysfunction underwent exercise radionuclide angiography and graded exercise treadmill testing. Each patient performed the tests in the single (VVIR) and dual (DDDR) chamber modes in a randomized, blinded fashion. We found that objective parameters such as ejection fraction (31% +/- 13% vs 31% +/- 10%), exercise tolerance (6.1 +/- 2.7 min vs 6.3 +/- 2.9 min), oxygen consumption (VO2) (941 +/- 286 mL/min vs 994 +/- 314 mL/min), carbon dioxide production (VCO2) (995 +/- 332 mL/min vs 1054 +/- 356 mL/min), and maximum attainable workload (43 +/- 24 W vs 46 +/- 22 W) did not differ between the single and dual chamber pacing modes. These findings suggest that in the acute setting, the additional cost and complexity of dual chamber, rate responsive pacing cannot be justified by objective improvements in exercise tolerance in patients with underlying left ventricular dysfunction.
Collapse
Affiliation(s)
- W W Barrington
- Department of Internal Medicine, University of Nebraska Medical Center, Omaha 68198-2265, USA
| | | | | | | | | |
Collapse
|
34
|
Abstract
A new carbon based oxygen sensor for rate adaptive cardiac pacing has been developed. It measures oxygen partial pressure In mixed venous blood. The system was implanted in six sheep with a mean follow-up time of 261 days after implant. The sensor reacted in a physiological manner when the animals were at rest as well as during exercise. Long-term sensor stability and sensitivity were satisfactory, and we found excellent correlation with spontaneous heart rate variations and with oxygen saturation measurements. The sensor shows great promise although our experience is still limited and further development on the concept is on-going.
Collapse
Affiliation(s)
- J Carlsten
- Swedish University of Agricultural Sciences, Uppsala
| | | | | |
Collapse
|
35
|
Nishino M, Ito T, Miyawaki M, Nakagawa T, Kuryu T, Tanahashi H, Yamada Y, Abe H. Benefits of rate-responsive pacing in patients with sick sinus syndrome. Angiology 1994; 45:353-60. [PMID: 8172382 DOI: 10.1177/000331979404500504] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
The effect of changing a rate-responsive pacemaker program (which reacts to evoked QT interval) to fixed-rate ventricular pacing was studied in 10 patients with sick sinus syndrome (SSS). After the patients had been in the rate-responsive mode (VVIR) for at least one year, the exercise capacity (maximal oxygen consumption [peak VO2], anaerobic threshold [AT], and cardiac output [CO] at these points) was examined. Three hours later on the same day, the pacemaker was reprogrammed to the fixed-rate pacing (VVI) and the exercise capacity was examined again (VVI-S). One month later, a similar exercise test was also done in the VVI mode (VVI-L). There was no significant difference in peak VO2 and AT between VVIR and VVI-S, but both peak VO2 and AT were significantly lower in VVI-L than in VVIR. However, there were no significant differences in the CO at peak VO2 or AT between any of the pacing modes. These findings indicate that a VVIR pacemaker should not be reprogrammed to the VVI mode in SSS patients, because the change can cause the exercise capacity to deteriorate.
Collapse
Affiliation(s)
- M Nishino
- Division of Cardiology, Osaka Rosai Hospital, Japan
| | | | | | | | | | | | | | | |
Collapse
|
36
|
Surdacki A, Bednarek J, Radziszewski W, Szczepkowski J, Dubiel JS, Ruskoaho H, Sedziwy L, Wieczorek E. Plasma ANP and cyclic GMP levels versus left ventricular performance at different AV delays in AV sequential pacing. Pacing Clin Electrophysiol 1994; 17:627-36. [PMID: 7516546 DOI: 10.1111/j.1540-8159.1994.tb02399.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Eleven resting patients with an implanted DDD pacemaker were studied. After 30 minutes of AV sequential pacing at a rate of 80 beats/min with three consecutive atrioventricular delays (AVDs; 100, 150, and 200 msec) peripheral venous blood was drawn for further analyses by specific radioimmunoassays of atrial natriuretic peptide (ANP) and the ANP second messenger, cyclic guanosine monophosphate (cGMP). Relative changes in left ventricular (LV) stroke volume following alterations of AVD were assessed by means of pulsed-Doppler echocardiography through measurement of LV outflow time-velocity integrals (TVI). The optimal AVD (oAVD) was defined in individual patients as that which was associated with the greatest TVI and with improvement over both other AVDs of more than 4%. The oAVD was found in nine patients. For these nine patients no significant differences in either plasma ANP or cGMP between various AVDs were observed. However, we found such differences with respect to values measured at oAVD; both ANP and cGMP levels were lowest at oAVD. Pooling together the data obtained in 11 patients at three AVDs, a positive correlation between ANP and cGMP levels was found (r = 0.7, P < 0.0001, n = 33). Moreover, changes of plasma ANP and cGMP induced by every AVD increment of 50 msec were also correlated (r = 0.6, P < 0.01, n = 22). It is concluded that in AV sequential pacing at rest plasma ANP reaches minimal levels at the AVD, which provides the best LV performance. Although levels of cGMP changed in parallel with those of ANP, low relative values of cGMP differences may limit the usefulness of cGMP assays in optimization of the AVD.
Collapse
Affiliation(s)
- A Surdacki
- Department of Cardiology, Jagiellonian University, Cracow, Poland
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Frielingsdorf J, Gerber AE, Dür P, Vuilliomenet A, Bertel O. Importance of an individually programmed atrioventricular delay at rest and on work capacity in patients with dual chamber pacemakers. Pacing Clin Electrophysiol 1994; 17:37-45. [PMID: 8139992 DOI: 10.1111/j.1540-8159.1994.tb01349.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Despite higher costs, expenditure, and the necessity of repeatedly reprogramming of dual chamber pacemakers, they are increasingly implanted to achieve an optimal work capacity. The influence of an individually programmed atrioventricular (AV) delay between 100-250 msec on physical work capacity in 12 patients (68 +/- 16 years) with dual chamber pacemakers implanted for high degree AV block was studied. During radionuclide ventriculography at rest the "optimal AV delay" with the maximal achieved left ventricular ejection fraction and the "most unfavorable AV delay" with the least achieved ejection fraction were determined. The ejection fraction at rest with the "optimal AV delay" was 51 +/- 14% and with the "most unfavorable AV delay" 45 +/- 15% (P < 0.001). In random order each patient was assigned to either AV delay and a spiroergometry was performed to determine maximum oxygen uptake (max VO2), which correlates best with work capacity, at a respiratory quotient of 1.1. The results show neither a difference in maximum oxygen uptake (1,262 +/- 446 mL/min with the optimal AV delay, 1,248 +/- 400 mL/min with the most unfavorable AV delay, respectively) nor in heart rate, blood pressure, exercise duration, maximal workload, and minute ventilation. Thus, an individually programmed AV delay affects left ventricular ejection fraction at rest. In contrast, an individually programmed AV delay has no influence on physical work capacity in patients with a dual chamber pacemaker.
Collapse
Affiliation(s)
- J Frielingsdorf
- Cardiology Division, University Hospital, Zürich, Switzerland
| | | | | | | | | |
Collapse
|
38
|
|
39
|
Greenhut SE, Svinarich JT, Randall NJ, Heald SC, Nappholz TA. Detection of atrial activation by intraventricular electrogram morphology analysis: a study to determine the feasibility of P wave synchronous pacing from a standard ventricular lead. Pacing Clin Electrophysiol 1993; 16:1293-303. [PMID: 7686659 DOI: 10.1111/j.1540-8159.1993.tb01716.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The detection of atrial activation from a standard ventricular pacing lead with standard ventricular electrodes would provide patients with VVI and VVIR pacing systems atrial rate response and atrial synchrony. In addition to potentially increasing cardiac output appropriately in these patients at rest and during moderate exercise, P wave sensing with such a device could help reduce pacemaker syndrome. In this study, unipolar signals from distal and proximal intraventricular electrodes were recorded from the right ventricular apex in 20 patients. Unipolar electrograms from 16 patients were recorded using temporary electrophysiology catheters and in four patients using permanent pacemaker leads. Approximately 3 minutes of data per patient were acquired and analyzed. After selection of a P wave template, the difference in baseline normalized area between the template and signal was calculated on a point-by-point basis. The percent of atrial depolarizations correctly detected was determined for each patient and lead configuration at the optimal threshold. Far-field P wave accuracy was better at the proximal electrode (74 +/- 25%) than at the distal electrode (57 +/- 34%) (P < 0.025). At the proximal electrode, 15/20 (75%) patients had > 70% accuracy and 11/20 (55%) patients had > 80% accuracy. At the distal electrode, 10/21 (48%) patients had > 70% accuracy and 7/21 (33%) patients had > 80% accuracy. In conclusion, far-field detection of atrial activation at the ventricular proximal electrode appears possible with sufficient accuracy to provide periods of atrial rate response and synchrony in patients with a single standard lead.
Collapse
Affiliation(s)
- S E Greenhut
- Applied Research Division, Telectronics Pacing Systems, Englewood, Colorado 80112
| | | | | | | | | |
Collapse
|
40
|
Benditt DG, Wilbert L, Hansen R, Alagona P, Greenawald K, Ghali MG, Wheelan K, Steinhaus D, Collins J, Fetter J. Late follow-up of dual-chamber rate-adaptive pacing. Am J Cardiol 1993; 71:714-9. [PMID: 8447271 DOI: 10.1016/0002-9149(93)91016-b] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Dual-chamber pacing systems with sensor-based rate-adaptive capability (DDDR pacemakers) provide paced patients with the potential benefits of both a reliable chronotropic response and maintenance of atrioventricular (AV) synchrony. However, there is concern that clinical and programming complexities may necessitate frequent reprogramming of pacemakers from the DDDR mode to less physiologic pacing modes (in particular VVI or VVIR). Consequently, this study assessed the stability of pacing-mode programming, and the factors affecting pacing-mode selection in patients with a DDDR-capable pacing system. Clinical status during follow-up (18.2 +/- 6.7 months) was assessed in 75 patients. Principal diagnoses providing an indication for pacing were: (1) AV block alone, 18 of 75 patients (24%); (2) sick sinus syndrome alone, 41 (55%); and (3) combined AV block and sick sinus syndrome, 16 (21%). Twenty-three patients had history of atrial tachyarrhythmias. At implantation, 66 devices (88%) were programmed to DDDR mode, 7 (9%) to DDD, and 2 (3%) to DVIR. At last follow-up, the respective distribution of programmed modes was 83% DDDR, 10% DDD, 4% DVIR and 3% VVIR. During the study, the initial pacing mode remained unchanged in 54 patients (72%) and needed modification in 21 (28%). Of the latter 21 patients, atrial tachycardia was the basis for a programming change in 11 (52%), of whom 8 had history of atrial tachycardias. In general, postimplant atrial arrhythmia occurrences proved controllable, and ultimately return to a rate-adaptive dual-chamber pacing mode (DDDR, DDD or DVIR) was achieved in most cases. The remaining reprogrammings were primarily to optimize hemodynamic benefit.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- D G Benditt
- Department of Medicine (Cardiovascular Division), University of Minnesota Medical School, Minneapolis 55455
| | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Linde-Edelstam CM, Juhlin-Dannfelt A, Nordlander R, Pehrsson SK. The hemodynamic importance of atrial systole: a function of the kinetic energy of blood flow? Pacing Clin Electrophysiol 1992; 15:1740-9. [PMID: 1279542 DOI: 10.1111/j.1540-8159.1992.tb02962.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The relative importance of atrial systole on left ventricular filling was investigated at rest and during exercise in 25 patients with dual chamber pacemakers. The mean blood flow velocity over the mitral valve, the velocities of the rapid filling phase (E), the active filling phase (A), and the E/A ratio were determined by pulsed Doppler-echocardiography. The patients were first examined at rest during AV sequential pacing (DVI) at 70 and 104 beats/min. The investigation was subsequently repeated during atrial synchronous pacing (VDD) at rest and during supine submaximal exercise at workloads adjusted to achieve heart rates corresponding to those during DVI pacing. The mean blood flow velocity at rest did not differ between DVI and VDD pacing at 70 beats/min (0.46 vs 0.49 m/sec). When the resting heart rate was increased to 104 beats/min (DVI) the mean blood flow velocity increased to 0.56 msec (P < 0.001). At a corresponding heart rate during exercise (VDD) the velocity increased to 0.70 msec (P < 0.001). At a resting heart rate of 70 beats/min the E/A ratio (n = 14) did not differ significantly between DVI and VDD pacing. With an increased resting heart rate (DVI) the E/A ratio decreased from 0.94 +/- 0.45 to 0.78 +/- 0.18; NS. When the heart rate increased during exercise (VDD) the E/A ratio increased from 0.75 +/- 0.14 to 0.97 +/- 0.16; P < 0.001. There was a positive correlation between the increase of the mean blood flow velocity and the increase of the E/A ratio during exercise (r = 0.69, P < 0.01). No such correlation was found when the heart rate was changed at rest. Thus, the importance of atrial systole on ventricular filling diminishes during exercise in accordance with increasing blood flow velocity, which by physical principles is related to the kinetic energy. The relative importance of atrial systole is hence inversely correlated to the kinetic energy of the blood flow.
Collapse
|
42
|
Capucci A, Boriani G, Specchia S, Marinelli M, Santarelli A, Magnani B. Evaluation by cardiopulmonary exercise test of DDDR versus DDD pacing. Pacing Clin Electrophysiol 1992; 15:1908-13. [PMID: 1279570 DOI: 10.1111/j.1540-8159.1992.tb02992.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
UNLABELLED In eight patients (age 62 +/- 6 years) a DDDR pacemaker was implanted for sick sinus syndrome (three cases) or second- and third-degree AV block (five cases). In five subjects chronotropic incompetence (maximal heart rate on effort < 110 beats/min) was present before implantation. One month after implantation the patients were randomized to DDDR or DDD pacing for 3 weeks each, with subsequent crossover, and at the end of each period a symptom limited cardiopulmonary exercise test (25 watts/2 min) was performed and the patients were requested to fill a symptoms questionnaire. RESULTS DDDR pacing, compared to DDD, was associated with higher maximal heart rates (127 +/- 20 vs 110 +/- 27 beats/min, P < 0.02), higher [VO2 max (25.4 +/- 6.1 vs 21.5 +/- 7.8 mL/kg/per min, P < 0.03) and higher VO2 at the anaerobic threshold (20.3 +/- 5.0 vs 15.8 +/- 4.9 mL/kg per min, P < 0.03), without significant differences in mean exercise time (526 +/- 193 vs 472 +/- 216 sec, NS). The increase in VO2 max obtained in DDDR versus DDD was significantly related to the increase in maximal heart rate (r = 0.72, P < 0.05) and the increase in VO2 at the anaerobic threshold obtained in DDDR versus DDD was related to the increase in heart rate at the anaerobic threshold (r = 0.81, P < 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- A Capucci
- Institute of Cardiovascular Diseases, University of Bologna, Italy
| | | | | | | | | | | |
Collapse
|
43
|
Lemke B, Dryander SV, Jäger D, Machraoui A, MacCarter D, Barmeyer J. Aerobic capacity in rate modulated pacing. Pacing Clin Electrophysiol 1992; 15:1914-8. [PMID: 1279571 DOI: 10.1111/j.1540-8159.1992.tb02993.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Whether heart rate or AV synchrony is the most important factor for an increase in aerobic capacity was evaluated in a comparative study between sinus bradycardia, VVIR, DDD, and DDDR stimulation. Sixteen patients (mean age 67 years) with chronotropic incompetence and implanted DDDR pacemaker (Telectronics META 1250) were randomly studied by cardiopulmonary exercise testing. All patients were exercised to their anaerobic threshold (AT) with the following heart rates: DDD 84 +/- 3, VVIR 110 +/- 5, and DDDR 116 +/- 6 beats/min. Mean oxygen uptake (VO2, mL/kg per min) at AT was 7.4 +/- 0.3 in DDD and VVIR modes. A 12% increase was measured in DDDR mode (8.3 +/- 0.4). Compared to VVIR work capacity in the DDDR mode was improved by 17% (41 vs 48 W/min). In patients with isolated sinus node disease (n = 9) the increase of VO2 and work capacity at AT during DDDR mode was more pronounced (16% and 20%, respectively, compared to VVIR). In patients with intermittent second or third degree AV block (n = 7) the differences between the pacing modes were not significant. This might partly be due to a lesser degree of chronotropic incompetence in this subgroup. In conclusion only the conjunction of heart rate increase and preservation of AV synchrony provides a significant improvement in aerobic capacity during exercise.
Collapse
Affiliation(s)
- B Lemke
- Department of Cardiology, University Hospital Bergmannsheil, Bochum, Germany
| | | | | | | | | | | |
Collapse
|
44
|
|
45
|
Soussou AI, Helmy MG, Guindy RR, Greco EM. A new acceleration driven pacemaker: rate modulation versus normal sinus rhythm--comparison during treadmill exercise. Pacing Clin Electrophysiol 1992; 15:1804-8. [PMID: 1279551 DOI: 10.1111/j.1540-8159.1992.tb02972.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The pacing rate response of a new acceleration driven pulse generator (SWING 100, SORIN BIOMEDICA) was compared with simultaneous normal sinus rhythm (NSR) during two different treadmill exercises. This pacemaker has a gravitational acceleration sensor able to discriminate between physical activities and vibrations. Six healthy volunteers (three male, three female; aged 21.7 +/- 4.3 years), with the pacemaker strapped to their right infraclavicular area, performed each test three times with different rise response curve (RRC) each time: fast, normal, and slow. The fall response curve used was the same as the rising one during each test. Pacing rates were recorded using the VEGA analyzer (SORIN BIOMEDICA) and compared with simultaneous NSR recorded by a 7-channel ECG recorder (MINGOGRAF 7, SIEMENS). During all tests immediate (within seconds) rapid increase in pacemaker rate was seen up to about 60 seconds, then a slower increase followed thereafter. The mean correlation between pacing rates and NSR during the Bruce tests were 0.7941 +/- 0.10, 0.8562 +/- 0.14, and 0.8292 +/- 0.07; during the discontinuous tests 0.7292 +/- 0.16, 0.7233 +/- 0.10, and 0.7480 +/- 0.11 for fast, normal, and slow RRC, respectively. Each 30 seconds, nonsignificant differences were present between pacing rate and NSR during all the discontinuous tests; similar responses were observed only during the first two stages of Bruce tests after which NSR was significantly higher than pacemaker rates. The speed of rise to upper rate was the main difference between the different programs (fast, normal, and slow). The discontinuous tests showed that the pacemaker responds more to speed than to grade.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- A I Soussou
- Italian Hospital Umberto I, Intensive Care Unit, Cairo, Egypt
| | | | | | | |
Collapse
|
46
|
Lundström T, Karlsson O. Improved ventilatory response to exercise after cardioversion of chronic atrial fibrillation to sinus rhythm. Chest 1992; 102:1017-22. [PMID: 1395736 DOI: 10.1378/chest.102.4.1017] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
The purpose of this study was to assess hemodynamic and respiratory measures of submaximal and maximal exercise performance in patients with chronic atrial fibrillation, before and one month after cardioversion to sinus rhythm. Restoration of sinus rhythm (n = 16) produced significant reductions in resting and exercise heart rates, 14 percent to 20 percent (p < 0.01). Due to a proportionately larger increase in stroke volume, cardiac output increased by 9 percent during low-level exercise (p < 0.01) and by 7 percent during exercise above the anaerobic threshold (p < 0.05). Minute ventilation was reduced by 7 percent during low-level exercise (p < 0.01) and by 9 percent above the anaerobic threshold (p < 0.05). The ratio between minute ventilation and carbon dioxide elimination was significantly reduced (p < 0.01). Maximum oxygen uptake (+8 percent; p < 0.01) and maximal tolerated work load (+6 percent; p < 0.05) increased. Hemodynamic changes during exercise were similar in patients with (n = 7) or without (n = 9) disopyramide prophylaxis. Restoration of sinus rhythm induced improvement in hemodynamics and in efficiency of ventilation, thereby reducing the ventilatory demand during submaximal exercise.
Collapse
Affiliation(s)
- T Lundström
- Department of Cardiology, Central Hospital, Skövde, Sweden
| | | |
Collapse
|
47
|
Abstract
Pacemaker technology has expanded rapidly in the last thirty years. Each phase of development has been marked by both improvements in clinical benefit and disadvantageous interactions of physiology and technology. Each phase of development has led to smaller, more reliable devices with greater programmability. Advances in generator technology and battery design have increased longevity of devices. The first devices used asynchronous pacing which had a significant effect in reducing the mortality of surgically induced complete heart block. Ventricular demand pacemakers overcame the problems of asynchronous competitive pacing, but exposed the pacemaker syndrome. Atrioventricular sequential pacing restored atrioventricular synchrony, resulting in hemodynamic improvement, but created the phenomenon of pacemaker-mediated tachycardia. Alternative dual chamber modes and algorithms have largely resolved this. Adaptive-rate devices have been of benefit to patients with chronotropic incompetence, and are now incorporating an increasing variety of biosensors. Almost all the problems of pacing have been overcome, but the increasing complexity of pacemaker technology is now a major limitation to its proper use.
Collapse
Affiliation(s)
- C F Shakespeare
- Department of Cardiological Sciences, St. George's Hospital Medical School, London, England
| | | |
Collapse
|
48
|
Linde-Edelstam C, Nordlander R, Pehrsson SK, Rydén L. A double-blind study of submaximal exercise tolerance and variation in paced rate in atrial synchronous compared to activity sensor modulated ventricular pacing. Pacing Clin Electrophysiol 1992; 15:905-15. [PMID: 1376903 DOI: 10.1111/j.1540-8159.1992.tb03081.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
To assess the variation in paced rate during everyday activity and the importance of atrioventricular synchronization (AV synchrony) for submaximal exercise tolerance, atrial synchronous (DDD) and activity rate modulated ventricular (VVI,R) pacing were compared in 17 patients with high degree AV block. The patients were randomly assigned to either mode and evaluated by treadmill exercise to moderate exertion and by 24-hour Holter monitoring after 2 months in the DDD and VVI,R modes, respectively. At the end of the study, the patients were programmed to the pacing mode corresponding to the preferred study period. During the treadmill test, the mean exercise time to submaximal exertion (Borg 5/10), exertion ratings and respiratory rate did not differ between pacing modes despite a significantly lower ventricular rate in the VVI,R mode. The atrial rate during VVI,R pacing was significantly higher than the ventricular rate, but did not differ from the ventricular rate during DDD pacing. There was a diurnal variation in paced rate in both pacing modes. Paced ventricular rate was, however, higher and variation in paced rate greater in DDD compared to VVI,R pacing. Nine patients preferred the DDD mode, three patients preferred the VVI,R mode, while five subjects did not express any preference. The results from this study indicate that the variation in paced rate during activity sensor-driven VVI,R pacing does not match that during DDD pacing neither during everyday activities nor during submaximal treadmill exercise. Nevertheless, no differences in exercise time, Borg ratings, and respiratory rate during submaximal exercise were found. Thus, for most patients with high degree AV block, DDD and VVI,R pacing seem equally satisfactory for submaximal exercise.
Collapse
Affiliation(s)
- C Linde-Edelstam
- Department of Cardiology, Karolinska Hospital, Stockholm, Sweden
| | | | | | | |
Collapse
|
49
|
Linde-Edelstam C, Hjemdahl P, Pehrsson SK, Aström H, Nordlander R. Is DDD pacing superior to VVI,R? A study on cardiac sympathetic nerve activity and myocardial oxygen consumption at rest and during exercise. Pacing Clin Electrophysiol 1992; 15:425-34. [PMID: 1374887 DOI: 10.1111/j.1540-8159.1992.tb05138.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Rate responsive ventricular pacing (VVI,R) has been demonstrated to equal atrial synchronous ventricular pacing (DDD) with regard to hemodynamics and exercise tolerance. Whether the two modes are also comparable, with regard to cardiac metabolic effects, is not yet clear. We assessed central hemodynamics, cardiac sympathetic nerve activity (cardiac norepinephrine overflow), and myocardial oxygen consumption in 16 patients treated with rate responsive atrial synchronous ventricular pacemakers (DDD,R) due to high degree AV block. The study was performed at rest and during supine exercise at two workloads (30 +/- 12 and 68 +/- 24 watts, respectively) during VDD and rate matched VVI pacing (VVIm). Ventricular rates at rest and during both workloads were almost identical. Cardiac output at rest tended to be higher in the VDD mode, due to a slightly higher stroke volume. Central pressures including right atrial pressure and pulmonary capillary wedge pressure were similar in the pacing modes. The coronary sinus blood flow, the coronary sinus arteriovenous oxygen difference, and the myocardial oxygen consumption did not differ between the two pacing modes. Cardiac norepinephrine overflow was similar in the two pacing modes, at rest or during exercise. Thus, we found no significant differences between VDD and VVIm pacing with regard to central hemodynamics, cardiac sympathetic nerve activity (cardiac norepinephrine overflow), or myocardial oxygen consumption either at rest or during moderate exercise.
Collapse
Affiliation(s)
- C Linde-Edelstam
- Department of Cardiology, Karolinska Hospital, Stockholm, Sweden
| | | | | | | | | |
Collapse
|
50
|
Abstract
Our review of the current literature and experience in caring for pacemaker patients suggests that a consideration of hemodynamics is a logical way to approach pacemaker selection and programming. Multiple clinical factors enter into the selection of a pacemaker or pacemaker programming settings in each case. It appears that in patients with sinus node disease, atrial-inhibited or dual-chamber pacing provides the best chance for preventing the development of chronic atrial fibrillation with its attendant risks of embolism and stroke. It is clear that AV synchrony has beneficial hemodynamic effects at rest in most patients. The results of Labovitz would suggest that in patients with marked left atrial enlargement, this may be less so. The results of Stewart et al would further suggest that in patients with retrograde VA conduction, dual-chamber pacing is preferable. Retrograde VA conduction can be intermittent and this makes it difficult to use its absence on a single test to decide on the type of pacemaker to use. It appears that baseline left ventricular function does not determine the relative improvement in cardiac output observed with AV synchrony or rate-adaptive pacing. However, in patients with severe congestive heart failure even a small improvement in cardiac output may result in significant clinical improvement. Studies have shown that in any given patient, there may be an optimal AV interval at rest. In general, this ranges from 100 to 150 milliseconds. In normal individuals the optimal AV interval shortens with increased heart rate during exercise in a predictable and linear fashion. The hemodynamic benefits of a shortened AV interval with faster heart rates in pacemaker patients have not yet been shown. Intuitively, however, this would appear to be a desirable approach and will probably be added to the design of future generations of dual-chamber pacemakers. Studies of the effect of different pacing modes on secretion of atrial natriuretic factor are intriguing and may contribute more to our understanding of pacing hemodynamics in the future. During exercise, heart rate increase is more important than AV synchrony and this has been shown by several studies. Thus, in active patients with chronotropic incompetence due to sick sinus syndrome, the addition of rate-adaptive pacing is important. Because single-chamber rate-adaptive atrial pacing leaves the patient exposed to the risk of future development of AV block and DDD pacing does not provide chronotropic support, it is likely that the new rate-adaptive dual-chamber (DDDR) devices will be used in a significant number of these patients.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|