1
|
Bahar AR, Khanal R, Hamza M, Goru RK, Shafiq A, Haider MZ, Basit SA, Bahar Y, Umer AM, Sattar Y, Alraies MC. Assessing the Efficacy of RADPAD Protection Drape in Reducing Radiation Exposure to Operators in the Cardiac Catheterization Laboratory: A Systematic Review and Meta-Analysis. Cureus 2024; 16:e59215. [PMID: 38807800 PMCID: PMC11132176 DOI: 10.7759/cureus.59215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/02/2024] [Indexed: 05/30/2024] Open
Abstract
One of the leading environmental hazards, ionizing radiation, is linked to several detrimental health consequences in the body. RADPAD (Worldwide Innovations & Technologies, Inc., Kansas City, Kansas) is a sterile, lead-free, lightweight, disposable radiation protection shield. We conducted a systematic review and meta-analysis to determine the effectiveness of RADPAD protection drapes in the cardiac catheterization lab and how they can aid interventional cardiologists in becoming subjected to less scatter radiation. PubMed, Embase, and Google Scholar were searched for studies discussing the efficacy of RADPAD protection drapes in reducing radiation exposure to operators in the cardiac catheterization laboratory. A random-effects model was used to pool odds ratios (ORs) and 95% confidence intervals (CIs) for endpoints: primary operator exposure dose, dose area product (DAP), relative exposure, and screening time. Our analysis included 892 patients from six studies. Compared to the No-RADPAD group, primary operator exposure dose (E) was significantly lower in the RADPAD group (OR: -0.9, 95% CI: -1.36 to -0.43, I2 = 80.5%, p = 0.0001). DAP was comparable between both groups (OR: 0.008, 95% CI: -0.12 to -0.14, I2 = 0%, p = 0.9066). There was no difference in the relative exposure (E/DAP) (OR: -0.47, 95% CI: -0.96 to 0.02, I2 = 0%, p = 0.90) and screening time (OR: 0.13, 95% CI: 0.08 to 0.35, I2 = 0%, p = 0.22) between the two groups. The interventional cardiology laboratory is exposed to significantly less scatter radiation during procedures owing to the RADPAD protective drape. Consequently, all catheterization laboratories could be advised to employ RADPAD protective drapes.
Collapse
Affiliation(s)
- Abdul Rasheed Bahar
- Internal Medicine, Wayne State University Detroit Medical Center, Detroit, USA
| | - Resha Khanal
- Internal Medicine, Wayne State University Detroit Medical Center, Detroit, USA
| | - Mohammad Hamza
- Internal Medicine, Guthrie Cortland Medical Center, Cortland, USA
| | - Rohit K Goru
- Internal Medicine, Wayne State University School of Medicine, Detroit, USA
| | - Aimen Shafiq
- Internal Medicine, Dow University of Health Sciences, Karachi, PAK
| | | | - Salman Abdul Basit
- Internal Medicine, The Wright Center for Graduate Medical Education, Scranton, USA
| | - Yasemin Bahar
- Internal Medicine, Wayne State University, Detroit, USA
| | - Ahmed Muaaz Umer
- Internal Medicine, Camden Clark Medical Center, Parkersburg, USA
| | - Yasar Sattar
- Cardiology, West Virginia University, Morgantown, USA
| | - M Chadi Alraies
- Cardiology, Wayne State University Detroit Medical Center, Detroit, USA
| |
Collapse
|
2
|
Shi HM, Sun ZC, Ju FH. Understanding the harm of low‑dose computed tomography radiation to the body (Review). Exp Ther Med 2022; 24:534. [PMID: 35911849 DOI: 10.3892/etm.2022.11461] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 05/24/2022] [Indexed: 11/06/2022] Open
Affiliation(s)
- Hai-Min Shi
- Department of Gynecology and Obstetrics Medicine, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, Zhejiang 310006, P.R. China
| | - Zhi-Chao Sun
- Department of Medical Imaging, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, Zhejiang 310006, P.R. China
| | - Fang-He Ju
- Department of Respiratory Medicine, The First Affiliated Hospital of Zhejiang Chinese Medical University, Zhejiang 310006, P.R. China
| |
Collapse
|
3
|
Lawson M, Parry G, Badawy MK. The use of patient drapes for staff dose reduction in fluoroscopically-guided interventions. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 43:10.1007/s13246-019-00831-9. [PMID: 31832985 DOI: 10.1007/s13246-019-00831-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Michael Lawson
- Monash Imaging, Monash Health, Clayton, VIC, 3168, Australia.
| | - Georgia Parry
- Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, VIC, 3800, Australia
| | - Mohamed K Badawy
- Monash Imaging, Monash Health, Clayton, VIC, 3168, Australia
- Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, VIC, 3800, Australia
| |
Collapse
|