1
|
Gould R, McFadden SL, Hughes CM. Radiation dose in paediatric cardiac catheterisation: A systematic literature review. Radiography (Lond) 2017; 23:358-364. [PMID: 28965901 DOI: 10.1016/j.radi.2017.02.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 02/01/2017] [Accepted: 02/03/2017] [Indexed: 12/23/2022]
Abstract
OBJECTIVES It is believed that children are more sensitive to ionising radiation than adults. This work reviewed the reported radiation dose estimates for paediatric cardiac catheterisation. A systematic literature review was performed by searching healthcare databases for studies reporting radiation dose using predetermined key words relating to children having cardiac catheterisation. The quality of publications was assessed using relevant Critical Appraisal Skills Programme questions and their reported radiation exposures were evaluated. KEY FINDINGS It is only in recent years that larger cohort observations have been undertaken. Although radiation dose from paediatric cardiac catheterisation has decreased in recent years, the literature indicated that it remains varied and potentially substantial. CONCLUSION Standardisation of weight categories and procedure types such as those recommended by the PiDRL project could help compare current and future radiation dose estimates.
Collapse
Affiliation(s)
- R Gould
- Institute of Nursing and Health Research, Ulster University, Jordanstown Campus, Shore Road, Newtownabbey, BT37 OQB, United Kingdom.
| | - S L McFadden
- Institute of Nursing and Health Research, Ulster University, Jordanstown Campus, Shore Road, Newtownabbey, BT37 OQB, United Kingdom
| | - C M Hughes
- Institute of Nursing and Health Research, Ulster University, Jordanstown Campus, Shore Road, Newtownabbey, BT37 OQB, United Kingdom
| |
Collapse
|
2
|
Truffa MAM, Alves GMP, Bernardi F, Esteves Filho A, Ribeiro E, Galon MZ, Spadaro A, Kajita LJ, Arrieta R, Lemos PA. Does Ad Hoc Coronary Intervention Reduce Radiation Exposure? - Analysis of 568 Patients. Arq Bras Cardiol 2015; 105:487-92. [PMID: 26351982 PMCID: PMC4651407 DOI: 10.5935/abc.20150110] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Accepted: 06/24/2015] [Indexed: 11/20/2022] Open
Abstract
Background Advantages and disadvantages of ad hoc percutaneous coronary intervention have
been described. However little is known about the radiation exposure of that
procedure as compared with the staged intervention. Objective To compare the radiation dose of the ad hoc percutaneous coronary intervention
with that of the staged procedure Methods The dose-area product and total Kerma were measured, and the doses of the
diagnostic and therapeutic procedures were added. In addition, total fluoroscopic
time and number of acquisitions were evaluated. Results A total of 568 consecutive patients were treated with ad hoc percutaneous coronary
intervention (n = 320) or staged percutaneous coronary intervention (n = 248). On
admission, the ad hoc group had less hypertension (74.1% vs 81.9%; p = 0.035),
dyslipidemia (57.8% vs. 67.7%; p = 0.02) and three-vessel disease (38.8% vs.
50.4%; p = 0.015). The ad hoc group was exposed to significantly lower radiation
doses, even after baseline characteristic adjustment between both groups. The ad
hoc group was exposed to a total dose-area product of 119.7 ± 70.7 Gycm2, while
the staged group, to 139.2 ± 75.3 Gycm2 (p < 0.001). Conclusion Ad hoc percutaneous coronary intervention reduced radiation exposure as compared
with diagnostic and therapeutic procedures performed at two separate times.
Collapse
Affiliation(s)
- Márcio A M Truffa
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Gustavo M P Alves
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Fernando Bernardi
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Antonio Esteves Filho
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Expedito Ribeiro
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Micheli Z Galon
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - André Spadaro
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Luiz J Kajita
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Raul Arrieta
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Pedro A Lemos
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| |
Collapse
|
3
|
Ubeda C, Vano E, Miranda P, Leyton F. Pilot program on patient dosimetry in pediatric interventional cardiology in Chile. Med Phys 2012; 39:2424-30. [DOI: 10.1118/1.3702590] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
4
|
Radiation exposure in children during the current era of pediatric cardiac intervention. Pediatr Cardiol 2012; 33:27-35. [PMID: 21811814 DOI: 10.1007/s00246-011-0064-z] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2011] [Accepted: 07/08/2011] [Indexed: 11/27/2022]
Abstract
Cardiac catheterizations are among the X-ray procedures with the highest patient radiation dose and therefore are of great concern in pediatric settings. This study aimed to evaluate factors that influence variability of X-ray exposure in children with congenital heart diseases during cardiac catheterization. The study included 107 children who underwent either diagnostic (n = 46) or interventional (n = 61) procedures. A custom-made sheet for patient and procedural characteristics was designed. Data were collected, and different correlations were applied to determine factors that influence variability of X-ray exposure. The fluoroscopy time (FT) differed significantly between the diagnostic (8.9 ± 6.3 min) and intervention (12.8 ± 9.98 min) groups (P = 0.032). The mean dose-area product (DAP) differed significantly between the two groups (3.775 ± 2.5 Gy/cm(2) vs. 13.239 ± 15.4 Gy/cm(2); P = 0.003). The highest DAP was during left anterior oblique (LAO) cranial 30° angulation (2.8 Gy/cm(2)/4 s cine). The mean cumulative dose (CD) was 0.053 Gy in diagnostic cases and 0.48 Gy in intervention cases. The effective dose was 5.97 ± 7.05 mSv for therapeutic procedures compared with 3.42 ± 3.64 mSv for diagnostic procedures. The FT correlated significantly with both the DAP (r = 0.718; P < 0.001) and the CD (r = 0.701; P < 0.001). Other correlations were reported. An increasing number of therapeutic catheterization procedures are being performed for children. The justification for these procedures is evident because they avoid complicated surgery. However, the complexity of these procedures results in higher radiation exposures.
Collapse
|
5
|
Beganović A, Kulić M, Spuzić M, Gazdić-Santić M, Skopljak-Beganović A, Drljević A, Dzanić S, Basić B, Lincender L. Patient doses in interventional cardiology in Bosnia and Herzegovina: first results. RADIATION PROTECTION DOSIMETRY 2010; 139:254-257. [PMID: 20223846 DOI: 10.1093/rpd/ncq085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Cardiologists at the Cardiac Centre of the Clinical Centre of Sarajevo University performed invasive cardiology procedures in one room equipped with a Siemens Coroskop (Siemens Healthcare, Erlangen, Germany) unit with the possibility of digital cine imaging. The number of procedures performed with this unit is 1126 per year. The number of adults performing only diagnostic procedures is 816, therapeutic procedures 62 and both diagnostic and therapeutic 228. Twenty diagnostic examinations but no therapeutic procedure are performed on children per year. The workload is increasing year by year, with an average increase of 26 % per year. The X-ray system does not have a kerma area product (KAP) meter installed; therefore an external KAP meter was mounted on the X-ray tube. Gafchromic dosimetry films (International Specialty Products, Wayne, USA) were placed under the patient to record the skin dose distribution. The peak skin dose (PSD) was calculated from the maximum optical density of the dosimetry films. Dose measurements were performed on 51 patients undergoing therapeutic procedures (percutaneous transluminal coronary angioplasty and stent placement). Two patients received doses (KAP) larger than 100 Gycm(2). The PSD was higher than 1 Gy in 3 out of 16 evaluations, and one of these patients received a skin dose >2 Gy. No deterministic skin effects were recorded. The dosimetry results are similar to results reported in other countries. Invasive cardiac procedures deliver high doses to the skin that could cause deterministic effects (erythema). Physicians performing these procedures should be aware of these risks. More efforts should be put into the training of cardiologists in radiation protection.
Collapse
Affiliation(s)
- Adnan Beganović
- Department of Medical Physics and Radiation Safety, Clinical Centre of Sarajevo University, Bolnicka 25, 71000 Sarajevo, Bosnia and Herzegovina.
| | | | | | | | | | | | | | | | | |
Collapse
|