1
|
First local diagnostic reference levels for fluoroscopically guided cardiac procedures in adult patients in Chile. NUCLEAR TECHNOLOGY AND RADIATION PROTECTION 2022. [DOI: 10.2298/ntrp2201084u] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
The goal of this study was to generate the first values of local diagnostic
reference levels for a range of fluoroscopically guided cardiac diagnostic
and therapeutic procedures in adult patients in Chile and to compare
radiation dose levels with others presented in the literature. The
dosimetric data collection period was conducted over the whole of 2020. The
local diagnostic reference levels were calculated as the 75th percentile
of patient dose data distributions for kerma area-product values. The sample
of collected clinical procedures (480) was divided into diagnostic and
therapeutic procedures. The kerma area-product differences found between
diagnostic and therapeutic procedures were statistically significant. The
local diagnostic reference levels were 81.6 Gy cm2 and 166.9 Gycm2 for
fluoroscopically guided cardiac diagnostic and therapeutic procedures,
respectively. A comparison of our results with results found in the
literature for the last 10 years, showed that there are no published papers
for hospitals in Latin America and the Caribbean. It becomes urgent to be
able to carry out more research of this type, given that the health
reality between countries on different continents is very different. While
in some the establishment of diagnostic reference levels is a legal obligation, in others it is a matter of good or bad will.
Collapse
|
2
|
Osman E, Sulieman A, Alzimami K, Tamam N, Jambi LK, Babikir E, Abd-Elghany AA, Abuzaid M, Omer H, Bradley D. Radiation exposure during therapeutic cardiac interventional procedures. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
3
|
Muhogora W, Rehani MM. Review of the current status of radiation protection in diagnostic radiology in Africa. J Med Imaging (Bellingham) 2017. [PMID: 28630886 DOI: 10.1117/1.jmi.4.3.031202] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The aim of this paper is to review the available published studies from African countries on patient doses and medical radiation protection and identify strengths, weaknesses, and challenges. Papers on radiation doses to patients published until 2016 pertaining to studies in African countries were reviewed. Radiography, interventional radiology, computed tomography (CT), and mammography modalities were covered. In radiography, the entrance surface air kerma values were below the established diagnostic reference levels (DRLs) provided by the International Atomic Energy Agency, European Commission, and National Council on Radiation Protection and Measurements. Patient and staff doses in interventional procedures were not on the higher side when compared with other published reports from developed countries. The dose length product values in CT in many situations were higher than established DRLs. In mammography, the variations of clinical image quality and dose to standard breast between African countries and other countries were insignificant. In conclusion, like in any continent, not all countries in Africa are active, but some have produced good results. The potential for optimization of radiation protection using simple and inexpensive techniques has been demonstrated. The lack of medical physicists is one of the important challenges.
Collapse
Affiliation(s)
| | - Madan M Rehani
- Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts, United States.,Duke University, Department of Radiology, Durham, North Carolina, United States
| |
Collapse
|
4
|
Uniyal SC, Chaturvedi V, Sharma SD, Rawat A. PATIENT DOSIMETRY DURING INTERVENTIONAL CARDIAC PROCEDURES IN A DEDICATED CATHETERIZATION LABORATORY. RADIATION PROTECTION DOSIMETRY 2017; 175:201-208. [PMID: 27744352 DOI: 10.1093/rpd/ncw286] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Accepted: 09/25/2016] [Indexed: 06/06/2023]
Abstract
Cardiac interventions often result in high radiation dose to patient's skin, so a reliable indicator in terms of a commonly used dose descriptor is required to monitor skin exposures. In the present study, Gafchromic XR-RV3 film was used to measure the peak skin dose (PSD) during 40 coronary angiography (CA) and 50 percutaneous transluminal coronary angioplasty (PTCA) procedures. Corresponding values of kerma-area product (PKA), fluoroscopy time (FT) and reference air-kerma (Ka,r) were recorded and correlated with PSD. Doses to patient's eyes and thyroid were also measured by using thermoluminescent dosimeters (TLDs) during PTCA procedures. The average dose to thyroid was about six times higher than the average dose to eyes. The mean values of PSD, PKA and FT were 1140 mGy, 97 Gy cm2 and 15.7 min for PTCA and 290 mGy, 21.1 Gy cm2 and 2.4 min for CA procedures, respectively. One in seven patients of PTCA procedure received PSD >2 Gy. With respect to FT, PKA may be used as a better predictor of skin exposures because the correlation of PSD with PKA was found better than with FT for both CA and PTCA procedures.
Collapse
Affiliation(s)
- Satish C Uniyal
- Department of Radiology, Himalayan Institute of Medical Sciences, Swami Rama Himalayan University, Jolly Grant, Dehradun 248016, India
| | - Vineet Chaturvedi
- Department of Radiology, Himalayan Institute of Medical Sciences, Swami Rama Himalayan University, Jolly Grant, Dehradun 248016, India
| | - Sunil D Sharma
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Anushaktinagar, Mumbai 400094, India
| | - Anurag Rawat
- Department of Cardiology, Himalayan Institute of Medical Sciences, Swami Rama Himalayan University, Jolly Grant, Dehradun 248016, India
| |
Collapse
|
5
|
Livingstone RS, Chase D, Varghese A, George PV, George OK. Transition from image intensifier to flat panel detector in interventional cardiology: Impact of radiation dose. J Med Phys 2015; 40:24-8. [PMID: 26150684 PMCID: PMC4471641 DOI: 10.4103/0971-6203.152241] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 12/05/2014] [Accepted: 12/08/2014] [Indexed: 11/04/2022] Open
Abstract
Flat panel detector (FPD) technology in interventional cardiology is on the increase due to its varied advantages compared to the conventional image intensifier (II) systems. It is not clear whether FPD imparts lower radiation doses compared to II systems though a few studies support this finding. This study intends to compare radiation doses from II and FPD systems for coronaryangiography (CAG) and Percutaneous Transluminal Coronary Angioplasty (PTCA) performed in a tertiary referral center. Radiation doses were measured using dose area product (DAP) meter from patients who underwent CAG (n = 222) and PTCA (n = 75) performed using FPD angiography system. The DAP values from FPD were compared with earlier reported data using II systems from the same referral center where the study was conducted. The mean DAP values from FPD system for CAG and PTCA were 24.35 and 63.64 Gycm(2) and those from II system were 27.71 and 65.44 Gycm(2). Transition from II to FPD system requires stringent dose optimization strategies right from the initial period of installation.
Collapse
Affiliation(s)
| | - David Chase
- Department of Cardiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Anna Varghese
- Department of Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Paul V George
- Department of Cardiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Oommen K George
- Department of Cardiology, Christian Medical College, Vellore, Tamil Nadu, India
| |
Collapse
|
6
|
Suliman II, Ibraheem SB, Youssif BE, Abdelgabar MI, Gafar R, Elshiekh E, Ahmed NA, Sulieman A. Examination frequency and population dose from medical X-ray examinations in Sudan in 2010. RADIATION PROTECTION DOSIMETRY 2015; 165:141-145. [PMID: 25836683 DOI: 10.1093/rpd/ncv106] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This study was performed to estimate examination frequency and collective and per caput effective doses arising from medical X-ray procedures in Sudan, 2010. Information was collected from 30 hospitals performing radiography, computed tomography (CT), fluoroscopy and interventional radiology (IR) procedures. The estimated annual number of examinations was 33 million radiographic X-ray procedures (99 %), 0.34 million CT exams per year (14 % paediatrics CT), 0.02 million fluoroscopy and IR procedures. The estimated annual number of examinations was 326 per 1000 people. The estimated annual collective and per caput effective doses from medical X-ray procedures mount 7197 man Sv and 0.18 mSv, respectively. The study offered the first projection of frequency and population dose from medical X-ray examinations in Sudan and provides estimates of the impact of the medical X-ray procedures at the national level.
Collapse
Affiliation(s)
- I I Suliman
- Department of Radiology and Molecular Imaging, Medical Physics Section, College of Medicine and Health Sciences, Sultan Qaboos University, PO Box 35, Post code 123, Al-Khod, Sultanate of Oman Sudan Atomic Energy Commission, Radiation Safety Institute, PO Box 3001, Khartoum, Sudan
| | - S B Ibraheem
- Sudan Atomic Energy Commission, Radiation Safety Institute, PO Box 3001, Khartoum, Sudan
| | - B E Youssif
- Sudan Atomic Energy Commission, Radiation Safety Institute, PO Box 3001, Khartoum, Sudan
| | | | - R Gafar
- Sudan Atomic Energy Commission, Radiation Safety Institute, PO Box 3001, Khartoum, Sudan
| | - E Elshiekh
- Sudan Atomic Energy Commission, Radiation Safety Institute, PO Box 3001, Khartoum, Sudan
| | - Nada A Ahmed
- Sudan Atomic Energy Commission, Radiation Safety Institute, PO Box 3001, Khartoum, Sudan
| | - A Sulieman
- Radiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, PO Box 422, Alkharj 11943, Saudi Arabia
| |
Collapse
|
7
|
Sulieman A, Alzimami K, Gafar R, Babikir E, Alsafi K, Suliman I. Occupational and patient exposure in coronary angiography procedures. Radiat Phys Chem Oxf Engl 1993 2014. [DOI: 10.1016/j.radphyschem.2013.12.028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
8
|
Cui Y, Zhang H, Zheng J, Yang X, Liang C. An investigation of patient doses during coronary interventional procedures in China. RADIATION PROTECTION DOSIMETRY 2013; 156:296-302. [PMID: 23528327 DOI: 10.1093/rpd/nct065] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The purpose of this study was to estimate patient doses during coronary angiography (CA) and different complex percutaneous transluminal coronary angioplasty (PTCA) procedures in China. Consecutive 290 patients (90 CA, 200 PTCA) with known or suspected coronary artery disease were enrolled prospectively into six groups. Differences in patient doses among the six groups were analysed, and the patient doses observed in this study were compared with the recent literature. The median dose area product values were 27.0 and 195.0 Gy cm(2) for CA and PTCA, respectively. The patient doses during CA were similar to those reported by other authors, while those during PTCA were higher. The differences in radiation doses depended on the complexity of the procedures. Enhanced knowledge of radiation doses may help cardiologists implement radiation-sparing procedures to minimise patient exposure.
Collapse
Affiliation(s)
- Yanhai Cui
- Department of Radiology, Guangdong Academy of Medical Sciences and Guangdong General Hospital, Guangzhou, China
| | | | | | | | | |
Collapse
|