Jansen JT, Shrimpton PC, Edyvean S. CT scanner-specific organ dose coefficients generated by Monte Carlo calculation for the ICRP adult male and female reference computational phantoms.
Phys Med Biol 2022;
67. [PMID:
36317285 DOI:
10.1088/1361-6560/ac9e3d]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 10/27/2022] [Indexed: 11/17/2022]
Abstract
Objective.Provide analyses of new organ dose coefficients (hereafter also referred to as normalized doses) for CT that have been developed to update the widely-utilized collection of data published 30 years ago in NRPB-SR250.Approach.In order to reflect changes in technology, and also ICRP recommendations concerning use of the computational phantoms adult male (AM) and adult female (AF), 102 series of new Monte Carlo simulations have been performed covering the range of operating conditions for 12 contemporary models of CT scanner from 4 manufacturers. Normalized doses (relative to free air on axis) have been determined for 39 organs, and for every 8 mm or 4.84 mm slab of AM and AF, respectively.Main results.Analyses of results confirm the significant influence (by up to a few tens of percent), on values of normalized organ (or contributions to effective dose (E103,phan)), for whole body exposure arising from selection of tube voltage and beam shaping filter. Use of partial (when available) rather than a Full fan beam reduced both organ and effective dose by up to 7%. Normalized doses to AF were larger than corresponding figures for AM by up to 30% for organs and by 10% forE103,phan. Additional simulations for whole body exposure have also demonstrated that: practical simplifications in the main modelling (point source, single slice thickness, neglect of patient couch and immobility of phantom arms) have sufficiently small (<5%) effect onE103,phan; mis-centring of the phantom away from the axis of rotation by 5 mm (in any direction) leads to changes in normalized organ dose andE103,phanby up to 20% and 6%, respectively; and angular tube current modulation can result in reductions by up to 35% and <15% in normalized organ dose andE103,phan, respectively, for 100% cosine variation.Significance.These analyses help advance understanding of the influence of operational scanner settings on organ dose coefficients for contemporary CT, in support of improved patient protection. The results will allow the future development of a new dose estimation tool.
Collapse