1
|
Yeom YS, Griffin K, Han H, Choi C, Shin B, Nguyen TT, Kim CH, Lee C. Dose conversion coefficients for neutron external exposures with five postures: walking, sitting, bending, kneeling, and squatting. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2021; 60:317-328. [PMID: 33704559 PMCID: PMC9923510 DOI: 10.1007/s00411-021-00900-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 02/20/2021] [Indexed: 06/12/2023]
Abstract
In a previous study, posture-dependent dose coefficients (DCs) for photon external exposures were calculated using the adult male and female mesh-type reference computational phantoms (MRCPs) of the International Commission on Radiological Protection (ICRP) that had been transformed into five non-standing postures (i.e. walking, sitting, bending, kneeling, and squatting). As an extension, the present study was conducted to establish another DC dataset for external exposures to neutrons by performing Monte Carlo radiation transport simulations with the adult male and female MRCPs in the five non-standing postures. The resulting dataset included the DCs for absorbed doses (i.e., organ/tissue-averaged absorbed doses) delivered to 29 individual organs/tissues, and for effective doses for neutron energies ranging from 10-9 to 104 MeV in six irradiation geometries: antero-posterior (AP), posteroanterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT), and isotropic (ISO) geometries. The comparison of DCs for the non-standing MRCPs with those of the standing MRCPs showed significant differences. In the lateral irradiation geometries, for example, the standing MRCPs overestimate the breast DCs of the squatting MRCPs by up to a factor of 4 due to the different arm positions but underestimate the gonad DCs by up to about 17 times due to the different leg positions. The impact of different postures on effective doses was generally less than that on organ doses but still significant; for example, the standing MRCPs overestimate the effective doses of the bending MRCPs only by 20% in the AP geometry at neutron energies less than 50 MeV, but underestimate those of the kneeling MRCPs by up to 40% in the lateral geometries at energies less than 0.1 MeV.
Collapse
Affiliation(s)
- Yeon Soo Yeom
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, 20850, USA
| | - Keith Griffin
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, 20850, USA
| | - Haegin Han
- Department of Nuclear Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea
| | - Chansoo Choi
- Department of Nuclear Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea
| | - Bangho Shin
- Department of Nuclear Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea
| | - Thang Tat Nguyen
- School of Nuclear Engineering and Environmental Physics, Hanoi University of Science and Technology, 1 Dai Co Viet road, Hai Ba Trung District, Hanoi, Vietnam
| | - Chan Hyeong Kim
- Department of Nuclear Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea.
| | - Choonsik Lee
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, 20850, USA
| |
Collapse
|
2
|
Sivabhaskar S, Perry A, Dewji S. Comparison of Neutron Organ and Effective Dose Coefficients for PIMAL Stylized Phantoms in Bent Postures in Cranial and Caudal Irradiation Geometries. HEALTH PHYSICS 2021; 120:559-572. [PMID: 33470713 DOI: 10.1097/hp.0000000000001382] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
ABSTRACT Radiation dose estimations in the human body are performed using computational reference phantoms, which are anatomical representations of the human body. In previous studies, dose reconstructions have been performed focusing primarily on phantoms in an upright posture, which limits the accuracy of the dose estimations for postures observed in realistic work settings. In this work, the International Commission on Radiological Protection (ICRP) Publication 103 recommendations for monoenergetic neutron plane sources directed downward from above the head (cranial) and upward from below the feet (caudal) for adult female and male reference phantoms were used to calculate organ absorbed and effective dose coefficients. The Phantom with Moving Arms and Legs (PIMAL) and the Monte Carlo N-Particle (MCNP) radiation transport code were used to compute organ-absorbed dose and effective dose coefficients for the upright, half-bent (45°), and full-bent (90°) phantom postures. The doses calculated for each of the articulated positions were compared to those calculated for the upright posture by computing the ratios of the coefficients (45°/upright and 90°/upright). These ratios were used to assess the effectiveness of upright phantoms in providing a comparable estimate when conducting dose estimations and dose reconstructions for articulated positions. This work compiling neutron cranial and caudal posture-specific dose coefficients completes the series of dose coefficients computed for posture-specific ICRP Publication 116 irradiation geometries for monoenergetic photons and neutrons, in addition to cranial and caudal monoenergetic photons. Results reported demonstrated that organ-absorbed dose coefficients for most of the organs in the CRA and CAU irradiation geometries were significantly higher for the bent phantoms than for the upright phantom. Since the upright phantom underestimates the organ-absorbed dose, this demonstrates the impact of posture while performing dose calculations. Organ doses reported in past neutron dose coefficient data were found to omit effects from neutron resonances at energies of 0.435, 1.0, and 3.21 MeV from 16O in tissue. Reported data notes as high as 60% underestimation for neutron organ-absorbed doses, specifically at the neutron resonance energy region omitted by smoothing. Ongoing studies are examining the effect of resonances on reported neutron organ-absorbed dose coefficients in ICRP 116 geometries.
Collapse
Affiliation(s)
| | - Alexander Perry
- Department of Nuclear Engineering, Texas A&M University, College Station, TX 77843
| | - Shaheen Dewji
- Department of Nuclear Engineering, Texas A&M University, College Station, TX 77843
| |
Collapse
|
3
|
Yeom YS, Han H, Choi C, Nguyen TT, Shin B, Lee C, Kim CH. Posture-dependent dose coefficients of mesh-type ICRP reference computational phantoms for photon external exposures. ACTA ACUST UNITED AC 2019; 64:075018. [DOI: 10.1088/1361-6560/ab0917] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
4
|
Bales K, Dewji S, Sanchez E. Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2018; 57:375-393. [PMID: 30167867 DOI: 10.1007/s00411-018-0751-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 08/03/2018] [Indexed: 06/08/2023]
Abstract
Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present work, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory's articulated stylized adult phantom, "Phantom wIth Moving Arms and Legs" (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10- 9 to 20 MeV for the ICRP Publication 116 external exposure geometries-antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses.
Collapse
Affiliation(s)
- K Bales
- Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN, USA
- Department of Nuclear Engineering, University of Tennessee, Knoxville, Knoxville, TN, USA
| | - S Dewji
- Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN, USA.
| | - E Sanchez
- Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN, USA
- Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| |
Collapse
|