1
|
Saki M, Grewal H, Artz M, Willoughby TR, Park J, Brooks E, Getman N, Senterfitt A, Johnson P. Navigating Complexities: Leadless Pacemaker Management in Proton Therapy for a Pacemaker-Dependent Bilateral Breast Cancer Patient. Int J Part Ther 2024; 13:100112. [PMID: 39105198 PMCID: PMC11298889 DOI: 10.1016/j.ijpt.2024.100112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 06/10/2024] [Accepted: 06/26/2024] [Indexed: 08/07/2024] Open
Abstract
This case study explores the strategic decision-making and safety considerations in managing a unique scenario where a pacemaker dependent patient, requiring adjuvant radiotherapy for bilateral breast cancer. The conventional pacemaker was located entirely within the treatment target, without the option for transposition because of the bilateral chest treatment, resulting in significant risk of malfunction caused by exposing it to the full prescribed dose. Consequently, the decision was made to replace the conventional pacemaker with a leadless device Micra implanted directly into the heart to mitigate direct device radiation and potential adverse effects of proton therapy on the cardiac device. Following Micra implantation, the patient underwent the proton treatment without complications or serious device malfunctions. This study explores solutions to address the challenges posed by within-the-field cardiac devices and highlights the use of pencil beam proton therapy for individuals with leadless cardiac devices while acknowledging the potential for neutron production and the associated risk of single-event upsets (SEU) in cardiac implantable electronic devices (CIEDs). The findings underscore the significance of strategic decision-making, risk assessment, and continuous monitoring for successful outcomes, particularly in the context of proton therapy for patients with advanced cardiac considerations.
Collapse
Affiliation(s)
- Mohammad Saki
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| | - Hardev Grewal
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| | - Mark Artz
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| | - Twyla R. Willoughby
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| | - Jiyeon Park
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| | - Eric Brooks
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| | - Nataly Getman
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| | - Abby Senterfitt
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| | - Perry Johnson
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA
| |
Collapse
|
2
|
Chen D, Motlagh SAO, Stappen FV, Labarbe R, Bell B, Kim M, Teo BKK, Dong L, Zou W, Diffenderfer ES. Secondary neutron dosimetry for conformal FLASH proton therapy. Med Phys 2024; 51:5081-5093. [PMID: 38597815 DOI: 10.1002/mp.17050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 03/12/2024] [Accepted: 03/13/2024] [Indexed: 04/11/2024] Open
Abstract
BACKGROUND Cyclotron-based proton therapy systems utilize the highest proton energies to achieve an ultra-high dose rate (UHDR) for FLASH radiotherapy. The deep-penetrating range associated with this high energy can be modulated by inserting a uniform plate of proton-stopping material, known as a range shifter, in the beam path at the nozzle to bring the Bragg peak within the target while ensuring high proton transport efficiency for UHDR. Aluminum has been recently proposed as a range shifter material mainly due to its high compactness and its mechanical properties. A possible drawback lies in the fact that aluminum has a larger cross-section of producing secondary neutrons compared to conventional plastic range shifters. Accordingly, an increase in secondary neutron contamination was expected during the delivery of range-modulated FLASH proton therapy, potentially heightening neutron-induced carcinogenic risks to the patient. PURPOSE We conducted neutron dosimetry using simulations and measurements to evaluate excess dose due to neutron exposure during UHDR proton irradiation with aluminum range shifters compared to plastic range shifters. METHODS Monte Carlo simulations in TOPAS were performed to investigate the secondary neutron production characteristics with aluminum range shifter during 225 MeV single-spot proton irradiation. The computational results were validated against measurements with a pair of ionization chambers in an out-of-field region ( ≤ $\le$ 30 cm) and with a Proton Recoil Scintillator-Los Alamos rem meter in a far-out-of-field region (0.5-2.5 m). The assessments were repeated with solid water slabs as a surrogate for the conventional range shifter material to evaluate the impact of aluminum on neutron yield. The results were compared with the International Electrotechnical Commission (IEC) standards to evaluate the clinical acceptance of the secondary neutron yield. RESULTS For a range modulation up to 26 cm in water, the maximum simulated and measured values of out-of-field secondary neutron dose equivalent per therapeutic dose with aluminum range shifter were found to be( 0.57 ± 0.02 ) mSv/Gy $(0.57\pm 0.02)\ \text{mSv/Gy}$ and( 0.46 ± 0.04 ) mSv/Gy $(0.46\pm 0.04)\ \text{mSv/Gy}$ , respectively, overall higher than the solid water cases (simulation:( 0.332 ± 0.003 ) mSv/Gy $(0.332\pm 0.003)\ \text{mSv/Gy}$ ; measurement:( 0.33 ± 0.03 ) mSv/Gy $(0.33\pm 0.03)\ \text{mSv/Gy}$ ). The maximum far out-of-field secondary neutron dose equivalent was found to be (8.8 ± 0.5 $8.8 \pm 0.5$ ) μ Sv / Gy $\umu {\rm Sv/Gy}$ and (1.62 ± 0.02 $1.62 \pm 0.02$ ) μ Sv / Gy $\umu {\rm Sv/Gy}$ for the simulations and rem meter measurements, respectively, also higher than the solid water counterparts (simulation: (3.3 ± 0.3 $3.3 \pm 0.3$ ) μ Sv / Gy $\umu {\rm Sv/Gy}$ ; measurement: (0.63 ± 0.03 $0.63 \pm 0.03$ ) μ Sv / Gy $\umu {\rm Sv/Gy}$ ). CONCLUSIONS We conducted simulations and measurements of secondary neutron production under proton irradiation at FLASH energy with range shifters. We found that the secondary neutron yield increased when using aluminum range shifters compared to conventional materials while remaining well below the non-primary radiation limit constrained by the IEC regulations.
Collapse
Affiliation(s)
- Dixin Chen
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | | - Rudi Labarbe
- Ion Beam Applications S.A. (IBA), Louvain-la-Neuve, Belgium
| | - Beryl Bell
- Ion Beam Applications S.A. (IBA), Louvain-la-Neuve, Belgium
| | - Michele Kim
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Boon-Keng Kevin Teo
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Lei Dong
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Wei Zou
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | |
Collapse
|
3
|
Tjelta J, Ytre-Hauge K, Lyngholm E, Handeland A, Henjum H, Stokkevåg C. Dose exposure to an adult present in the treatment room during pediatric pencil beam scanning proton therapy. Acta Oncol 2023; 62:1531-1535. [PMID: 37676843 DOI: 10.1080/0284186x.2023.2254924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 08/29/2023] [Indexed: 09/09/2023]
Affiliation(s)
- Johannes Tjelta
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | | | - Erlend Lyngholm
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - Andreas Handeland
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - Helge Henjum
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - Camilla Stokkevåg
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| |
Collapse
|
4
|
Tawonwong T, Suriyapee S, Dachviriyakij T, Pungkun V, Ruangchan S, Sanghangthum T. Measurement of Ambient Dose Equivalent in Compact Proton Therapy using In-house Neutron Moderator-based Poly Allyl Diglycol Carbonate. J Med Phys 2023; 48:243-247. [PMID: 37969145 PMCID: PMC10642591 DOI: 10.4103/jmp.jmp_35_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 06/14/2023] [Accepted: 06/15/2023] [Indexed: 11/17/2023] Open
Abstract
Purpose The high-energy proton produces the unwanted dose contribution from the secondary neutron. The main purpose of this study is to report the validation results of in-house neutron moderator based on poly allyl diglycol carbonate (CR-39) detector, Chulalongkorn University Neutron Moderator (CUMOD) through the ambient dose equivalent, H*(10) measurement. Materials and Methods The Particle and Heavy Ion Transport code System (PHITS) Monte Carlo code was used to simulate the neutron response function. The CUMOD was calibrated with 241AmBe source calibrator in the range of 100-1000 μSv. The variation of neutron fields was generated employing different proton treatment plans covering most of the clinical scenarios. The ambient dose equivalents, H*(10), evaluated employing CUMOD were compared to those obtained with WENDI-II dosimeter. Results The linear relationship between CUMOD and WENDI-II responses showed an R2 value close to 1. The H*(10) per Gy delivered dose was in the range of 22-105 μSv for a 10 cm × 10 cm field. Conclusion The in-house CUMOD neutron moderator can expand the neutron detection dose range of CR-39 detector for ambient dose equivalent. The advantage of CUMODs is its capability to evaluate H*(10) in various positions simultaneously.
Collapse
Affiliation(s)
- Tanawat Tawonwong
- Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Her Royal Highness Princess Maha Chakri Sirindhorn Proton Center, Bangkok, Thailand
- Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
| | - Sivalee Suriyapee
- Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Department of Radiology, Division of Radiation Oncology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Tanapol Dachviriyakij
- Nuclear and Radiation Metrology Section, Regulatory Support Division, Office of Atoms for Peace, Bangkok, Thailand
| | - Vithit Pungkun
- Nuclear and Radiation Metrology Section, Regulatory Support Division, Office of Atoms for Peace, Bangkok, Thailand
| | - Sirinya Ruangchan
- Her Royal Highness Princess Maha Chakri Sirindhorn Proton Center, Bangkok, Thailand
- Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
| | - Taweap Sanghangthum
- Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Her Royal Highness Princess Maha Chakri Sirindhorn Proton Center, Bangkok, Thailand
- Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
- Department of Radiology, Division of Radiation Oncology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
5
|
Zhou J, Di Fulvio A, Beyer KA, Ferrarini M, Pullia M, Donetti M, Clarke SD, Pozzi SA. Angular distribution of neutron production by proton and carbon-ion therapeutic beams. Phys Med Biol 2020; 65:155002. [PMID: 32197258 DOI: 10.1088/1361-6560/ab81ca] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.
Collapse
Affiliation(s)
- J Zhou
- Department of Nuclear, Plasma and Radiological Engineering, University of Illinois at Urbana-Champaign, 104 South Wright Street Urbana, IL 61801-2957, United States of America
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Hälg RA, Schneider U. Neutron dose and its measurement in proton therapy-current State of Knowledge. Br J Radiol 2020; 93:20190412. [PMID: 31868525 PMCID: PMC7066952 DOI: 10.1259/bjr.20190412] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 12/06/2019] [Accepted: 12/19/2019] [Indexed: 12/26/2022] Open
Abstract
Proton therapy has shown dosimetric advantages over conventional radiation therapy using photons. Although the integral dose for patients treated with proton therapy is low, concerns were raised about late effects like secondary cancer caused by dose depositions far away from the treated area. This is especially true for neutrons and therefore the stray dose contribution from neutrons in proton therapy is still being investigated. The higher biological effectiveness of neutrons compared to photons is the main cause of these concerns. The gold-standard in neutron dosimetry is measurements, but performing neutron measurements is challenging. Different approaches have been taken to overcome these difficulties, for instance with newly developed neutron detectors. Monte Carlo simulations is another common technique to assess the dose from secondary neutrons. Measurements and simulations are used to develop analytical models for fast neutron dose estimations. This article tries to summarize the developments in the different aspects of neutron dose in proton therapy since 2017. In general, low neutron doses have been reported, especially in active proton therapy. Although the published biological effectiveness of neutrons relative to photons regarding cancer induction is higher, it is unlikely that the neutron dose has a large impact on the second cancer risk of proton therapy patients.
Collapse
|
7
|
Isobe T, Mori Y, Takei H, Sato E, Sakae T. [14. Biological Dose and Effects of Neutrons in Proton Beam Therapy]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2020; 76:863-869. [PMID: 32814743 DOI: 10.6009/jjrt.2020_jsrt_76.8.863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Affiliation(s)
| | | | | | - Eisuke Sato
- Faculty of Health Science, Juntendo University
| | | |
Collapse
|