1
|
Alhailiy A, Alkhybari E, Alshuhri M, Al-Othman A, Hegazi T, Alsuhaimi M, Alghamdi S, Alenazi K, Alashban Y, Alghamdi S, Quzi O, Jaafari O, Alajlani S, Masmali A, Hadi Y, Manssor E, Mahmoud M. Proposing Multiregional Diagnostic Reference Levels for Common CT Angiography Examinations in Saudi Arabia. Diagnostics (Basel) 2024; 14:1523. [PMID: 39061660 PMCID: PMC11275626 DOI: 10.3390/diagnostics14141523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 07/03/2024] [Accepted: 07/09/2024] [Indexed: 07/28/2024] Open
Abstract
OBJECTIVES Diagnostic reference levels (DRLs) are crucial tools for optimizing radiation exposure during different radiological examinations. This study aimed to establish preliminary DRLs for commonly performed computed tomographic angiography (CTA) examinations in Saudi Arabia. METHODS Data for three types of CTA examinations (cerebral, pulmonary, and lower-extremity) were collected from six medical cities across Saudi Arabia. Data sets related to 723 CTAs with a mean patient weight of 75 kg were analysed in detail. The DRL values were determined based on the 75th, median, and 25th CT dose index volume (CTDIvol) and dose length product (DLP) values. RESULTS The established DRLs were 1221 mGy cm for cerebral CTAs, 475 mGy cm for pulmonary CTAs, and 1040 mGy cm for lower-extremity CTAs. These values were comparable to those reported in other studies. CONCLUSIONS This study provides preliminary DRLs for three common CTA procedures in Saudi Arabia. The widespread implementation of a low kVp and a high level of image reconstruction (IR) presents an opportunity for further dose reduction. These findings can serve as a foundation for future nationwide DRL surveys and the optimization of CTA imaging protocols in Saudi Arabia.
Collapse
Affiliation(s)
- Ali Alhailiy
- Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Alkharj 11942, Saudi Arabia; (E.A.); (M.A.)
| | - Essam Alkhybari
- Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Alkharj 11942, Saudi Arabia; (E.A.); (M.A.)
| | - Mohammed Alshuhri
- Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Alkharj 11942, Saudi Arabia; (E.A.); (M.A.)
| | - Abdullah Al-Othman
- Radiology Department, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Dammam 34221, Saudi Arabia; (A.A.-O.); (T.H.); (M.A.)
| | - Tarek Hegazi
- Radiology Department, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Dammam 34221, Saudi Arabia; (A.A.-O.); (T.H.); (M.A.)
| | - Mohammed Alsuhaimi
- Radiology Department, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Dammam 34221, Saudi Arabia; (A.A.-O.); (T.H.); (M.A.)
| | - Sultan Alghamdi
- Radiology and Nuclear Medicine Department, Security Force Hospital, Riyadh 11481, Saudi Arabia;
| | - Khaled Alenazi
- Radiological Sciences Department, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia; (K.A.); (Y.A.); (S.A.)
| | - Yazeed Alashban
- Radiological Sciences Department, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia; (K.A.); (Y.A.); (S.A.)
| | - Sami Alghamdi
- Radiological Sciences Department, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia; (K.A.); (Y.A.); (S.A.)
| | - Omar Quzi
- Department of Radiology and Medical Imaging, King Fahad Central Hospital, Jazan Health Cluster, Jazan 82725, Saudi Arabia;
| | - Osama Jaafari
- Radiology Department, Royal Commission Medical Centre, Industrial Yanbu, Yanbu 46451, Saudi Arabia; (O.J.); (S.A.); (A.M.)
| | - Saleh Alajlani
- Radiology Department, Royal Commission Medical Centre, Industrial Yanbu, Yanbu 46451, Saudi Arabia; (O.J.); (S.A.); (A.M.)
| | - Abdulrahman Masmali
- Radiology Department, Royal Commission Medical Centre, Industrial Yanbu, Yanbu 46451, Saudi Arabia; (O.J.); (S.A.); (A.M.)
| | - Yasser Hadi
- Department of Medical Imaging and Intervention, King Abdullah Medical City, Makkah 57657, Saudi Arabia;
- Discipline of Medical Imaging and Radiation Therapy, University College Cork, T12 K8AF Cork, Ireland
| | - Elbagir Manssor
- Department of Radiologic Technology, College of Applied Medical Sciences, University of Jeddah, Jeddah 23218, Saudi Arabia;
| | - Mustafa Mahmoud
- Department of Radiological Sciences, College of Applied Medical Sciences, King Khalid University, Abha 62521, Saudi Arabia;
| |
Collapse
|
2
|
Kędzierski B, Macek P, Dziadkowiec-Macek B, Truszkiewicz K, Poręba R, Gać P. Radiation Doses in Cardiovascular Computed Tomography. Life (Basel) 2023; 13:990. [PMID: 37109519 PMCID: PMC10141413 DOI: 10.3390/life13040990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 04/03/2023] [Accepted: 04/07/2023] [Indexed: 04/29/2023] Open
Abstract
We discussed the contemporary views on the effects of ionising radiation on living organisms and the process of estimating radiation doses in CT examinations and the definitions of the CTDI, CTDIvol, DLP, SSDE, ED. We reviewed the reports from large analyses on the radiation doses in CT examinations of the coronary arteries prior to TAVI procedures, including the CRESCENT, PROTECTION, German Cardiac CT Registry studies. These studies were carried out over the last 10 years and can help confront the daily practice of performing cardiovascular CT examinations in most centres. The reference dose levels for these examinations were also collected. The methods to optimise the radiation dose included tube voltage reduction, ECG-monitored tube current modulation, iterative and deep learning reconstruction techniques, a reduction in the scan range, prospective study protocols, automatic exposure control, heart rate control, rational use of the calcium score, multi-slices and dual-source and wide-field tomography. We also present the studies that indicated the need to raise the organ conversion factor for cardiovascular studies from the 0.014-0.017 mSv/mGy*cm used for chest studies to date to a value of 0.0264-0.03 mSv/mGy*cm.
Collapse
Affiliation(s)
- Bartłomiej Kędzierski
- Department of Radiology and Imaging Diagnostics, Emergency Medicine Center, Marciniak Lower Silesian Specialist Hospital, Fieldorfa 2, 54-049 Wrocław, Poland
| | - Piotr Macek
- Department of Internal Medicine, Occupational Diseases, Hypertension and Clinical Oncology, Wroclaw Medical University, Borowska 213, 50-556 Wrocław, Poland
| | - Barbara Dziadkowiec-Macek
- Department of Internal Medicine, Occupational Diseases, Hypertension and Clinical Oncology, Wroclaw Medical University, Borowska 213, 50-556 Wrocław, Poland
| | - Krystian Truszkiewicz
- Department of Radiology and Imaging Diagnostics, Emergency Medicine Center, Marciniak Lower Silesian Specialist Hospital, Fieldorfa 2, 54-049 Wrocław, Poland
| | - Rafał Poręba
- Department of Internal Medicine, Occupational Diseases, Hypertension and Clinical Oncology, Wroclaw Medical University, Borowska 213, 50-556 Wrocław, Poland
| | - Paweł Gać
- Department of Population Health, Division of Environmental Health and Occupational Medicine, Wroclaw Medical University, Mikulicza-Radeckiego 7, 50-368 Wrocław, Poland
| |
Collapse
|
3
|
Albahiti SK, Barnawi RA, Alsafi K, Khafaji M, Aljondi R, Alghamdi SS, Awan Z, Sulieman A, Jafer M, Tamam N, Tajaldeen A, Mattar EH, Al-Malki KM, Bradley D. Establishment of institutional diagnostic reference levels for 6 adult computed tomography examinations: Results from preliminary data collection. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110477] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
4
|
Jusoh II, Abdullah KA, Ali MH. DIAGNOSTIC REFERENCE LEVELS FOR COMMON CT EXAMINATIONS: RESULTS FROM A STATEWIDE DOSE SURVEY. RADIATION PROTECTION DOSIMETRY 2022; 198:1417-1423. [PMID: 36093894 DOI: 10.1093/rpd/ncac182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/09/2022] [Accepted: 08/17/2022] [Indexed: 06/15/2023]
Abstract
The aim of this study was to investigate the current radiation doses for CT examinations throughout a state in Malaysia and, based on this data, to propose local diagnostic reference levels (DRLs) for the most common CT examinations. A study was conducted in three of the four hospitals that have provided CT services throughout the state. A survey booklet was designed to facilitate collection of pertinent CT scan data. The following information were extracted and recorded for each study: tube voltage, tube current, number of scans phases, CT dose index volume (CTDIvol) and dose length product (DLP). Proposed local DRLs of CT brain and thorax were up to 12% lower than the current national DRLs. However, an increase of DLP (median value) for CT abdomen was also found as compared to the 75th percentile of national DRLs. Therefore, considerable optimisation should be made to achieve a better dose reduction.
Collapse
Affiliation(s)
- Irwan Iskandar Jusoh
- School of Medical Imaging, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Kuala Nerus, Terengganu 21300, Malaysia
| | - Kamarul Amin Abdullah
- School of Medical Imaging, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Kuala Nerus, Terengganu 21300, Malaysia
| | - Mohd Hanafi Ali
- Discipline of Medical Imaging Science, Sydney School of Health Sciences, Faculty of Medicine and Health, Level 7, University of Sydney, D18 Susan Wakil Health Building, Western Avenue, Camperdown, NSW 2006, Australia
| |
Collapse
|
5
|
Chen LG, Wu PA, Tu HY, Sheu MH, Huang LC. DIAGNOSTIC REFERENCE LEVELS OF CARDIAC COMPUTED TOMOGRAPHY ANGIOGRAPHY IN A SINGLE MEDICAL CENTER IN TAIWAN: A 3-Y ANALYSIS. RADIATION PROTECTION DOSIMETRY 2021; 194:36-41. [PMID: 33969422 DOI: 10.1093/rpd/ncab068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 03/02/2021] [Accepted: 04/13/2021] [Indexed: 06/12/2023]
Abstract
This study aimed to establish the diagnostic reference levels (DRLs) for coronary computed tomography angiography (CCTA) and coronary arterial calcium score (CACS) owing to a large variability in patient radiation dose and the lack of dose recommendations in Taiwan. Volume computed tomography dose index (CTDIvol) and dose-length product (DLP) were obtained using CCTAs and the CACS of 445 patients over a 3-y period in a single medical center in Taiwan. CCTAs were performed using routine protocols and 256-detector CT scanners. Electrocardiogram gating was retrospective. The obtained data were analyzed using Prism 6 to determine the 25th, 50th (median) and 75th DRL percentiles for CTDIvol and DLP. These DRL results were compared with existing DRLs from seven countries. The DRLs for CCTA determined from this survey were similar to the existing data from other countries. Such DRLs could provide a useful tool for the optimization of radiation dose for CCTA in Taiwan.
Collapse
Affiliation(s)
- Li-Guo Chen
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien 97002, Taiwan
| | - Ping-An Wu
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien 97002, Taiwan
| | - Hsing-Yang Tu
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien 97002, Taiwan
| | - Ming-Huei Sheu
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien 97002, Taiwan
| | - Li-Chuan Huang
- Department of Medical Imaging, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien 97002, Taiwan
- Department of Medical Imaging and Radiological Sciences, Tzu Chi University of Science and Technology, Hualien 97005, Taiwan
| |
Collapse
|
6
|
Alkhorayef M, Sulieman A, Alzahrani K, Abuzaid M, Alomair OI, Almuwannis M, Alghamdi S, Tamam N, Bradley DA. Radiation risk for patients undergoing cardiac computed tomography examinations. Appl Radiat Isot 2020; 168:109520. [PMID: 33307438 DOI: 10.1016/j.apradiso.2020.109520] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Revised: 07/06/2020] [Accepted: 11/13/2020] [Indexed: 11/28/2022]
Abstract
The various technological advancements in computed tomography (CT) have resulted in remarkable growth in the use of CT imaging in clinical practice, not the least of which has been its establishment as the most valuable imaging examination for the assessment of cardiovascular system disorders. The objective of this study was to assess the effective radiation dose and radiation risk for patients during cardiac CT procedures, based on studies from four different hospitals equipped with 128 slice CT equipment. A total of eighty-three patients were investigated in this study with different clinical indications. Effective doses were also calculated using software based on Monte Carlo simulation. The mean patient age (years), weight (kg), and body mass index (BMI (kg/m2)) were 49 ± 11, 82 ± 12, and 31 ± 6, respectively. The results of the study revealed that the tube voltage (kVp) and tube current-exposure time product (mAs) ranged between 100 to 140 and 50 to 840 respectively. The overall average patient dose values for the volume CT dose index [(CTDIvol), in mGy)] and dose length product (DLP) (in mGy·cm) were 34.8 ± 15 (3.7-117.0) and 383.8 ± 354 (46.0-3277.0) respectively. The average effective dose (mSv) was 15.2 ± 8 (1.2-61.8). The radiation dose values showed wide variation between different hospitals and even within the same hospital. The results indicate the need to optimize radiation dose and to establish diagnostic reference levels (DRLs) for patients undergoing coronary computed tomography angiography (CCTA), also to harmonize the imaging protocols to ensure reduced radiation risk.
Collapse
Affiliation(s)
- M Alkhorayef
- Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O Box 10219, Riyadh, 11433, Saudi Arabia; Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford, Surrey, GU2 7XH, UK.
| | - A Sulieman
- Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P.O.Box 422, Alkharj, 11942, Saudi Arabia
| | - Khalid Alzahrani
- General Administration of Radiology and Applied Services, Ministry of Health, Riyadh, Saudi Arabia
| | - Mohamed Abuzaid
- Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, United Arab Emirates
| | - Othman I Alomair
- Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O Box 10219, Riyadh, 11433, Saudi Arabia
| | - M Almuwannis
- Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O Box 10219, Riyadh, 11433, Saudi Arabia
| | - Salem Alghamdi
- College of Applied Medical Sciences, Department of Medical Imaging and Radiation Sciences, University of Jeddah, Jeddah, Saudi Arabia
| | - Nissren Tamam
- Physics Department, College of Sciences, Princess Nourah Bint Abdulrahman University, P.O Box 84428, Riyadh, 11671, Saudi Arabia
| | - David A Bradley
- Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford, Surrey, GU2 7XH, UK; Sunway University, Centre for Biomedical Physics, Jalan Universiti, 46150, PJ, Malaysia
| |
Collapse
|
7
|
Xu J, Wang X, Xiao H, Xu J. Size-Specific Dose Estimates Based on Water-Equivalent Diameter and Effective Diameter in Computed Tomography Coronary Angiography. Med Sci Monit 2019; 25:9299-9305. [PMID: 31808424 PMCID: PMC6911303 DOI: 10.12659/msm.917980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2019] [Accepted: 08/21/2019] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND To determine the difference in size-specific dose estimates (SSDEs), separately based on effective diameter (deff) and water equivalent diameter (dw) of the central slice of the scan range in computed tomography coronary angiography (CTCA). MATERIAL AND METHODS There were 134 patients who underwent CTCA examination, were electronically retrieved. SSDEs (SSDEdeff and SSDEdw) were calculated using 2 approaches: deff and dw. The median SSDEs and mean absolute relative difference of SSDEs were calculated. Linear regression model was used to assess the absolute relative difference of SSDEs based on the ratio of deff to dw. RESULTS The median values of SSDEdeff and SSDEdw were 18.26 mGy and 20.56 mGy, respectively (P<0.01). The former was about 10.08% smaller than the latter. The mean absolute relative difference of SSDEs was 10.48%, ranging from 0.33% to 24.16%. A considerably positive correlation was found between the absolute relative difference of SSDEs and the ratio of deff to dw (R²=0.9561, r=0.979, P<0.01). CONCLUSIONS The value of SSDEdeff was smaller by an average of about 10.08% than SSDEdw in CTCA, and the absolute relative difference increased linearly with the ratio of effective diameter to water equivalent diameter.
Collapse
|
8
|
Rawashdeh M, Saade C, Zaitoun M, Abdelrahman M, Brennan P, Alewaidat H, McEntee MF. Establishment of diagnostic reference levels in cardiac computed tomography. J Appl Clin Med Phys 2019; 20:181-186. [PMID: 31469229 PMCID: PMC6807208 DOI: 10.1002/acm2.12711] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Revised: 08/03/2019] [Accepted: 08/07/2019] [Indexed: 11/14/2022] Open
Abstract
The aim of this study was to determine diagnostic reference levels (DRLs) for cardiac computed tomography (CCT) in Jordan. Volume computed tomography dose index (CTDIvol) and dose–length product (DLP) were collected from 228 CCTs performed at seven Jordanian hospitals specialized in cardiac CT. DRLs for cardiac CT were defined at the 75th percentile of CTDIvol and DLP. CTDIvol and DLP were collected from 30 successive cardiac CT in each center except for one center (18 scans). The 75th percentile of the CTDIvol and the DLP of the centers calculated from mixed retrospective and prospective gated modes were 47.74 milligray (mGy) and 1035 mGy/cm, respectively. This study demonstrated wide dose variations among the surveyed hospitals for cardiac CT scans; there was a 5.1‐fold difference between the highest and lowest median DLP with a range of 223.2–1146.7 mGy/cm. Differences were associated with variations in the mAs and kVp. This study confirmed large variability in CTDIvol and DLP for cardiac CT scans; variation was associated with acquisition protocols and highlights the need for dose optimization. DRLs are proposed for CCT; there remains substantial potential for optimization of cardiac CT examinations for adults in Jordan.
Collapse
Affiliation(s)
- Mohammad Rawashdeh
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Charbel Saade
- Department of Diagnostic Radiology, American University of Beirut Medical Center, Beirut, Lebanon
| | - Maha Zaitoun
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Mostafa Abdelrahman
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Patrick Brennan
- Faculty of Health Sciences, Medical Image Optimization and Perception Group (MIOPeG), and the Brain and Mind Centre, The University of Sydney, Sydney, NSW, Australia
| | - Haytham Alewaidat
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Mark F McEntee
- Discipline of Diagnostic Radiography, UG 12 Aras Watson, Brookfield Health Sciences, University College Cork, College Road, Cork, Ireland
| |
Collapse
|
9
|
Alhailiy AB, Ekpo EU, Kench PL, Ryan EA, Brennan PC, McEntee M. The associated factors for radiation dose variation in cardiac CT angiography. Br J Radiol 2019; 92:20180793. [PMID: 30633548 DOI: 10.1259/bjr.20180793] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
OBJECTIVE: This study aimed to examine the associated factors for dose variation and influence cardiac CT angiography (CCTA) dose benchmarks in current CT imaging centres. METHODS: A questionnaire was distributed to CT centres across Australia and Saudi Arabia. All participating centres collected data for adults who underwent a CCTA procedure. The questionnaire gathered information about the examination protocol, scanning parameters, patient parameters, and volume CT dose index (CTDI vol) and dose-length product (DLP). A stepwise regression analysis was performed to assess the contribution of tube voltage (kV), padding time technique, cross-sectional area (CSA) of chest and weight to DLP. RESULTS: A total of 17 CT centres provided data for 423 CCTA examinations. The median CTDIvol, DLP and effective dose were 18 mGy, 256 mGy.cm and 5.2 mSv respectively. There was a statistically significant difference in DLP between retrospective and prospective ECG-gating modes (p = 0.001). Median DLP from CCTA using padding technique was 61% higher than CCTA without padding (p = 0.001). The stepwise regression showed that kV was the most significant predictor of DLP followed by padding technique then CSA while patient weight did not statistically significantly predict DLP. Correlation analysis showed a strong positive correlation between weight and CSA (r = 0.78), and there was a moderate positive correlation between weight and DLP (r = 0.42), as well as CSA and DLP (r = 0.48). CONCLUSION: Findings show radiation dose variations for CCTA. The associated factors for dose variation found in this study are scanning mode, kV, padding time technique and CSA of the chest. This results support the need to include CSA measurements in future dose survey and for setting DRLs. ADVANCES IN KNOWLEDGE: The study provides baseline information that helps to understand the associated factors for dose variations and high doses within and between centres performing CCTA.
Collapse
Affiliation(s)
- Ali B Alhailiy
- 1 The University of Sydney, Faculty of Health Sciences, Discipline of Medical Radiation Science , Sydney, NSW , Australia.,2 Prince Sattam Bin Abdulaziz University , Al-Kharj , Kingdom of Saudi Arabia
| | - Ernest U Ekpo
- 1 The University of Sydney, Faculty of Health Sciences, Discipline of Medical Radiation Science , Sydney, NSW , Australia
| | - Peter L Kench
- 1 The University of Sydney, Faculty of Health Sciences, Discipline of Medical Radiation Science , Sydney, NSW , Australia
| | - Elaine A Ryan
- 1 The University of Sydney, Faculty of Health Sciences, Discipline of Medical Radiation Science , Sydney, NSW , Australia
| | - Patrick C Brennan
- 1 The University of Sydney, Faculty of Health Sciences, Discipline of Medical Radiation Science , Sydney, NSW , Australia
| | - Mark McEntee
- 1 The University of Sydney, Faculty of Health Sciences, Discipline of Medical Radiation Science , Sydney, NSW , Australia
| |
Collapse
|