1
|
Hathi K, Nam YSJ, Fowler J, Dishan B, Madou E, Sowerby LJ, MacNeil SD, Nichols AC, Strychowsky JE. Improving Operating Room Efficiency in Otolaryngology-Head and Neck Surgery: A Scoping Review. Otolaryngol Head Neck Surg 2024; 171:946-961. [PMID: 38769856 DOI: 10.1002/ohn.822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 04/04/2024] [Accepted: 04/27/2024] [Indexed: 05/22/2024]
Abstract
OBJECTIVE One minute of operating room (OR) time costs $36 to 37. However, ORs are notoriously inefficient. There is growing literature on improving OR efficiency, but no formal review of this topic within otolaryngology has been performed. This study reviews and synthesizes the current literature on improving OR efficiency within otolaryngology. DATA SOURCES MEDLINE, EMBASE, Web of Science, CINAHL, Cochrane Library, preprints.org, and medRxiv were searched on November 4, 2022. REVIEW METHODS Published English studies were included if they reported on metrics for improving OR efficiency within otolaryngology. There were no publication date restrictions. Articles were screened by 2 reviewers. Preferred Reporting Items for Systematic Reviews and Meta-analysis reporting for scoping reviews was followed. RESULTS The search yielded 9316 no-duplicate articles; 129 articles were included. Most of the studies reported on head and neck procedures (n = 52/129). The main tactics included surgical considerations: hemostatic devices, techniques, and team/simultaneous approaches; anesthetic considerations: local anesthetic and laryngeal mask airways; procedure location considerations: procedures outside of the OR and remote technologies; standardization: equipment, checklists, and personnel; scheduling considerations: use of machine learning for booking, considering patient/surgeon factors, and utilizing dedicated OR time/multidisciplinary teams for on-call cases. CONCLUSION The current literature brings to attention numerous strategies for improving OR efficiency within otolaryngology. Applying these strategies and implementing novel techniques to manage surgical cases may assist in offloading overloaded health care systems and improving access to care while facilitating patient safety and outcomes. Anticipated barriers to implementation include resistance to change, funding, and the current strain on health care systems and providers.
Collapse
Affiliation(s)
- Kalpesh Hathi
- Department of Surgery, Division of Otolaryngology-Head and Neck Surgery, Dalhousie University, Halifax, Nova Scotia, Canada
| | - You Sung Jon Nam
- Dalhousie Medicine New Brunswick, Saint John, New Brunswick, Canada
| | - James Fowler
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Canada
| | - Brad Dishan
- Corporate Academics, Health Sciences Library, London Health Sciences Center, London, Ontario, Canada
| | - Edward Madou
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Canada
| | - Leigh J Sowerby
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Canada
| | - S Danielle MacNeil
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Canada
| | - Anthony C Nichols
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Canada
| | - Julie E Strychowsky
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Canada
| |
Collapse
|
2
|
Arora RD, Prajwal SD, Rao KN, Singh A, Nagarkar NM, Abishek AP. A Comparison of Harmonic Scalpel and Conventional Techniques for Thyroidectomy. Indian J Otolaryngol Head Neck Surg 2023; 75:3410-3414. [PMID: 37974807 PMCID: PMC10645797 DOI: 10.1007/s12070-023-04002-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 06/16/2023] [Indexed: 11/19/2023] Open
Abstract
Thyroidectomy is one of the most frequently performed surgeries. Conventional techniques using electrocautery carry the risk of tissue injury. Recently, there has been increased use of harmonic scalpels in thyroid surgery. The harmonic scalpel utilizes ultrasonic shears for cutting and coagulation, thus minimizing thermal injury. The objective of our study was to determine differences in operative duration, hypocalcemia, and RLN palsy. This single-center retrospective comparative study included consecutive patients undergoing hemithyroidectomies using the harmonic scalpel and conventional technique in the past one year (n = 64, harmonic group = 28 and conventional group = 36). The mean operative duration for the harmonic scalpel group was 70.4 min, vs. 81.31 min for the conventional technique group, and the difference in mean duration was found to be 10.84 min (p = 0.027). There was no statistically significant difference in the rates of hypocalcemia (p = 0.751) or RLN palsy (p = 0.121). None of the patients in either group developed permanent hypocalcemia or RLN palsy. The use of a harmonic scalpel during thyroidectomy is safe. The overall surgical duration was reduced when the harmonic scalpel was used, and the complication rates were comparable to those of the conventional technique, making it a non-inferior technique for surgical intervention in thyroidectomy and warranting harmonic scalpel consideration as a valuable addition to the armamentarium of thyroid surgeons.
Collapse
Affiliation(s)
- Ripu Daman Arora
- Department of Otolaryngology and Head Neck Surgery, All India Institute of Medical Sciences, Raipur, Chhattisgarh India
| | - S. D. Prajwal
- Department of Head and Neck Oncology, All India Institute of Medical Sciences, Raipur, Chhattisgarh India
| | - Karthik Nagaraja Rao
- Department of Head and Neck Oncology, All India Institute of Medical Sciences, Raipur, Chhattisgarh India
| | - Ambesh Singh
- Department of Head and Neck Oncology, All India Institute of Medical Sciences, Raipur, Chhattisgarh India
| | | | - A. P. Abishek
- Department of Otolaryngology and Head Neck Surgery, All India Institute of Medical Sciences, Raipur, Chhattisgarh India
| |
Collapse
|
3
|
Ho J, Kim D, Lee JE, Kim JK, Lee CR, Kang SW, Jeong JJ, Nam KH, Chung WY. Single-Port Transaxillary Robotic Modified Radical Neck Dissection (STAR-RND): Initial Experiences. Laryngoscope 2023; 133:709-714. [PMID: 36308330 DOI: 10.1002/lary.30437] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 07/12/2022] [Accepted: 09/18/2022] [Indexed: 11/05/2022]
Abstract
OBJECTIVES This study aimed to demonstrate the usefulness of single-port transaxillary robotic modified radical neck dissection (STAR-RND) for metastatic thyroid cancer, and its potential to make small and invisible surgical wounds possible compared to open modified radical neck dissection. METHODS Between January 2020 and July 2021, 30 thyroid cancer patients who underwent lateral neck dissection surgery with the da Vinci SP at Yonsei University Health System (Seoul, Korea) were studied. RESULTS All 30 patients, diagnosed with papillary thyroid cancer were women. The average operating time was 293.80 ± 36.58 (min), and the average postoperative hospital stay was 4.77 ± 0.57 (days). All patients were discharged after the expected number of hospitalization days without major complications. CONCLUSION STAR-RND is technically feasible and safe with a short length of the incision. To our knowledge, this is the first report on the use of a single-port robotic system for modified radical neck dissection. LEVEL OF EVIDENCE BY USING 2011 OCEBM: 4 Laryngoscope, 133:709-714, 2023.
Collapse
Affiliation(s)
- Joon Ho
- Department of Surgery, Severance Hospital, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Donggyu Kim
- Department of Surgery, Severance Hospital, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Ji-Eun Lee
- Department of Surgery, Severance Hospital, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Jin Kyong Kim
- Department of Surgery, Severance Hospital, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Cho Rok Lee
- Department of Surgery, Yongin Severance Hospital, Gyeonggi-do, South Korea
| | - Sang-Wook Kang
- Department of Surgery, Severance Hospital, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Jong Ju Jeong
- Department of Surgery, Severance Hospital, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Kee-Hyun Nam
- Department of Surgery, Severance Hospital, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Woong Youn Chung
- Department of Surgery, Severance Hospital, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| |
Collapse
|
4
|
Kim JK, Choi SH, Choi SM, Choi HR, Lee CR, Kang SW, Jeong JJ, Nam KH, Chung WY. Single-port transaxillary robotic thyroidectomy (START): 200-cases with two-step retraction method. Surg Endosc 2021; 36:2688-2696. [PMID: 34741206 PMCID: PMC8921151 DOI: 10.1007/s00464-021-08837-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 10/19/2021] [Indexed: 12/03/2022]
Abstract
Background This study aims to report the results of a pioneering clinical study using the single-port transaxillary robotic thyroidectomy (START) for 200 patients with thyroid tumor and to introduce our novel two-step retraction method. Methods START was performed on consecutive 200 patients using the da Vinci Single-Port (SP) robot system from January 2019 to September 2020 at the Yonsei University Health System, Seoul, Korea. The novel two-step retraction technique, in which a 3.5 cm long incision is made along the natural skin crease, was used for the latter 164 patients. The surgical outcome and invasiveness of the SP two-step retraction method were analyzed. Results Among the 200 cases who underwent START, 198 were female and 2 were male, with a mean age of 34.7 (range: 13–58 years). Thyroid lobectomy was performed for 177 patients and total thyroidectomy was performed for 23 patients. Ten patients had benign thyroid nodules, whereas the other 190 had thyroid malignancy. The mean body mass index (BMI) was 22.2 ± 3.7 kg/m2 (range: 15.9–37.0 kg/m2). All of the operations were performed successfully without any open conversions, and patients were discharged on postoperative day 3 or 4 without significant complication. The mean operative time for thyroid lobectomy with the two-step retraction method was 116.69 ± 23.23 min, which was similar to that in the conventional robotic skin flap method (115.33 ± 17.29 min). We could minimize the extent of the robotic skin flap dissection with the two-step retraction method. Conclusions START is a practical surgical method. By employing the new two-step retraction method, we can maximize the cosmetic and functional benefits for patients and reduce the workload fatigue of surgeons by increasing robotic dependency. Supplementary Information The online version contains supplementary material available at 10.1007/s00464-021-08837-9.
Collapse
Affiliation(s)
- Jin Kyong Kim
- Department of Surgery, Yonsei Cancer Center, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea
| | - Sun Hyung Choi
- Department of Surgery, Yonsei Cancer Center, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea
| | - Soon Min Choi
- Department of Surgery, Yonsei Cancer Center, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea
| | - Hye Ryeon Choi
- Department of Surgery, Yonsei Cancer Center, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea
| | - Cho Rok Lee
- Department of Surgery, Yongin Severance Hospital, Gyeonggi-do, Korea
| | - Sang-Wook Kang
- Department of Surgery, Yonsei Cancer Center, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea
| | - Jong Ju Jeong
- Department of Surgery, Yonsei Cancer Center, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea
| | - Kee-Hyun Nam
- Department of Surgery, Yonsei Cancer Center, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea.
| | - Woong Youn Chung
- Department of Surgery, Yonsei Cancer Center, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea
| |
Collapse
|
5
|
Jiang J, Shen M, Lu H. Ultrasonic scalpel with knot tying protects parathyroid function for total thyroidectomy with central neck dissection. Gland Surg 2020; 9:192-199. [PMID: 32420242 DOI: 10.21037/gs.2020.01.12] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Background Hypoparathyroidism might be due to collateral thermal injury induced by harmonic scalpel (HS) after total thyroidectomy (TT) with central neck dissection (CND). The current study aimed to evaluate whether a clamp and tie (CAT) technique used to preserve parathyroid glands in situ could reduce damage to parathyroid function in HS patients undergoing TT plus unilateral or bilateral CND. Methods Medical records of 537 HS-operated patients with papillary thyroid carcinoma (PTC) undergoing TT plus unilateral or bilateral CND were retrospectively evaluated. Patients were divided into HS and HS-CAT groups based on whether the CAT techniques were used near parathyroid glands. Patients' characteristics such as age, sex, tumour size, operative time, pre- and post-operative levels of parathyroid hormone (PTH) and complications were analysed. Results For patients undergoing TT plus unilateral CND, operative time was significantly shorter (P<0.001), but there were significantly higher incidences of transient hypoparathyroidism (P=0.002) on postoperative day 1 and incidental parathyroidectomy (P=0.036) in the HS group. There was no significant difference in permanent hypoparathyroidism. For patients undergoing TT plus bilateral CND, a significantly shorter operative time and sharper postoperative PTH decline was found in the HS group (P=0.029). However, there were no significant differences regarding incidences of incidental parathyroidectomy, transient or permanent hypoparathyroidism. Conclusions The CAT technique applied near parathyroid glands was a practical surgical application for decreasing the incidence of postoperative transient hypoparathyroidism for TT plus unilateral CND.
Collapse
Affiliation(s)
- Jun Jiang
- Department of General Surgery, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China
| | - Meiping Shen
- Department of General Surgery, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China
| | - Hui Lu
- Department of General Surgery, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China
| |
Collapse
|
6
|
Kim SM, Bae JM, Choi MG, Lee JH, Sohn TS, Kim S. Oncological safety of use of ultrasonic activated shears in gastric cancer surgery: Long-term results of randomized controlled trial. Chin J Cancer Res 2018; 30:492-499. [PMID: 30510360 PMCID: PMC6232358 DOI: 10.21147/j.issn.1000-9604.2018.05.02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Objective Ultrasonically activated shears (UAS) have been applied in open gastric surgeries with no or little evidence. It was previously reported about the surgical outcome and effectiveness of UAS based on a randomized controlled trial of 256 patients with gastric cancer. We aimed to clarify the long-term oncological safety of the use of UAS in the aspect of overall survival and recurrence. Methods Gastric cancer patients who underwent gastrectomy with D2 lymph node dissection were enrolled and randomly assigned to either the conventional surgery group (n=125) or the UAS group (n=128). Survival, recurrence and long-term postoperative complications were compared between the two groups. The median follow-up period was 56 months. Results Gastric cancer-related death was higher in patients of the UAS group compared with the conventional group (P=0.019). Overall survival rates stratified by stage were not significantly different between the two groups (P=0.170). Disease-free survival rates stratified by stage and recurrence-free survival rates of gastric cancer were similar between the conventional group and the UAS group (P=0.313 and 0.199, respectively). The postoperative complication rate was not significantly different between the groups (P=1.000). Conclusions It is suggested that the use of UAS in gastrectomy for gastric cancer showed oncologically acceptable safety compared with conventional electric instruments even in long-term period.
Collapse
Affiliation(s)
- Su Mi Kim
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
| | - Jae-Moon Bae
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
| | - Min-Gew Choi
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
| | - Jun Ho Lee
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
| | - Tae Sung Sohn
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
| | - Sung Kim
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
| |
Collapse
|
7
|
Aires FT, Matos LLD, Dedivitis RA, Cernea CR. Effectiveness of harmonic scalpel in patients submitted to total thyroidectomy: systematic review with meta-analysis. Rev Assoc Med Bras (1992) 2018; 64:649-657. [DOI: 10.1590/1806-9282.64.07.649] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Accepted: 12/06/2017] [Indexed: 11/22/2022] Open
|
8
|
Chávez KV, Barajas EM, Soroa F, Gamboa-Dominguez A, Ordóñez S, Pantoja JP, Sierra M, Velázquez-Fernández D, Herrera MF. Safety assessment of the use of ultrasonic energy in the proximity of the recurrent laryngeal nerve in a porcine model. Am J Surg 2017. [PMID: 28622836 DOI: 10.1016/j.amjsurg.2017.04.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Advanced bipolar and ultrasonic energy have demonstrated reduction of operating time and blood loss in thyroidectomy. However, these devices generate heat and thermal dispersion that may damage adjacent structures such as the recurrent laryngeal nerve (RLN). This study was designed to evaluate the safety profile of the Harmonic Focus+® (HF+) device through the evaluation of thermal injury to the RLN using different algorithms of distance and time with state of the art technology. METHODS 25 Vietnamese pigs underwent activation of HF+ in the proximity of their RLN. They were divided into 4 groups according to activation distance (3 mm, 2 mm, 1 mm and on the RLN). Time of activation, time between tones of the ultrasonic generator, changes in the electromyographic signal using continuous nerve neuromonitoring, vocal fold mobility assessed by direct laryngoscopy and histological thermal damaged were evaluated. RESULTS None of the pigs had loss of signal in the electromyography during the procedure; only one pig had isolated transient decrease in amplitude and one increase in latency. One pig had transient vocal fold paresis in the group with activation on the nerve. Evaluation of the nerves by histology and immunohistochemistry did not show significant changes attributed to thermal injury. CONCLUSIONS The use of ultrasonic energy close to the RLN is safe, provided that activation time does not exceed the necessary time to safely transect the tissue.
Collapse
Affiliation(s)
- Karla V Chávez
- Service of Endocrine Surgery, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Elpidio M Barajas
- Service of Endocrine Surgery, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Francisco Soroa
- Service of Otolaryngology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Armando Gamboa-Dominguez
- Department of Pathology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Samuel Ordóñez
- Service of Endocrine Surgery, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Juan P Pantoja
- Service of Endocrine Surgery, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Mauricio Sierra
- Service of Endocrine Surgery, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - David Velázquez-Fernández
- Service of Endocrine Surgery, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Miguel F Herrera
- Service of Endocrine Surgery, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico.
| |
Collapse
|
9
|
Viability of Airborne Tumor Cells during Excision by Ultrasonic Device. Surg Res Pract 2017; 2017:4907576. [PMID: 28492061 PMCID: PMC5401725 DOI: 10.1155/2017/4907576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2016] [Revised: 02/26/2017] [Accepted: 03/23/2017] [Indexed: 11/17/2022] Open
Abstract
Background. Laparoscopic surgery has become more widely used, but peritoneal dissemination and port-site metastasis have been reported to occur in these surgeries. One reason for these problems is the ultrasonically activated scalpel (UAS) used for laparoscopic surgery. This study aimed to investigate the viability of airborne cells released during cancer dissection using a UAS. Methods. Flank tumors measuring about 2 cm were induced in male NOD-Cg-Rag1tm1MomIL2rgtm1wjl/SzJ mice by subcutaneous injection of 1 × 106 HepG2 cells. Dissection was performed with UAS (in high or low power modes) and PowerStar bipolar scissors. The mist of released tissue was collected in cell culture medium. The viability of the cellular material was assessed with trypan blue exclusion cell counting, counting after immunofluorescence staining, and flow cytometric analysis. Results. Large quantities of cellular debris were trapped in the tissue dispersed by both devices. In all experiments, there were significantly more viable cells produced by the UAS in high power mode. By using suction at the excision site, the number of viable cancer cells was reduced. Conclusions. This study demonstrates that viable cancer cells can be released into the nearby environment during tumor ablation with a UAS.
Collapse
|
10
|
Advanced vessel sealing devices in total thyroidectomy for substernal goitre: A retrospective cohort study. Int J Surg 2016; 35:160-164. [DOI: 10.1016/j.ijsu.2016.09.092] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 08/31/2016] [Accepted: 09/24/2016] [Indexed: 02/03/2023]
|
11
|
A comparison of surgical outcomes and complications between hemostatic devices for thyroid surgery: a network meta-analysis. Eur Arch Otorhinolaryngol 2016; 274:1269-1278. [DOI: 10.1007/s00405-016-4190-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 06/28/2016] [Indexed: 11/25/2022]
|
12
|
Cheng H, Soleas IM, Ferko NC, Cameron CG, Clymer JW, Amaral JF. Hospital costs associated with thyroidectomy performed with a Harmonic device compared to conventional techniques: a systematic review and meta-analysis. J Med Econ 2016; 19:750-8. [PMID: 26999563 DOI: 10.3111/13696998.2016.1168826] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVES Harmonic devices have become a world-wide standard for dissection and hemostasis in thyroidectomy. Numerous systematic reviews have reported superior operating times, blood loss, post-operative pain, length of stay, and overall safety outcomes. What has not been extensively evaluated in a robust manner is their economic impact. The purpose of this study is to evaluate the hospital costs associated with open thyroidectomy using Harmonic devices compared with conventional techniques for hemostasis. METHODS A systematic review of Medline, Scopus, and CENTRAL was performed from January 1, 2000 to May 23, 2014 without language restrictions for randomized clinical trials comparing Harmonic surgical devices to conventional methods in thyroidectomy. The main outcome measure was total reported costs. Costs were pooled using the ratio of means and a random effects model. Sensitivity analyses assessed whether differences in patient and trial characteristics, healthcare setting, or choice of statistical model affected outcomes. RESULTS Seven studies met the inclusion criteria. A total of 476 participants had procedures performed with Harmonic devices and 478 with conventional monopolar electrosurgery and clamp, cut and tie techniques. Compared with conventional techniques, Harmonic devices reduced total reported costs by 10% (p = 0.007), resulting in a $229 US dollars (USD) absolute reduction from mean baseline costs. Results remained relatively robust to additional sensitivity analyses. CONCLUSIONS This systematic review and meta-analysis demonstrates that the Harmonic family of surgical devices is associated with a reduction in total reported costs in thyroidectomy compared with conventional techniques. A large portion of the overall savings derives from a reduction in operative costs.
Collapse
|
13
|
Upadhyaya A, Hu T, Meng Z, Li X, He X, Tian W, Jia Q, Tan J. Harmonic versus LigaSure hemostasis technique in thyroid surgery: A meta-analysis. Biomed Rep 2016; 5:221-227. [PMID: 27446546 DOI: 10.3892/br.2016.691] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Accepted: 05/18/2016] [Indexed: 01/21/2023] Open
Abstract
Harmonic scalpel and LigaSure vessel sealing systems have been suggested as options for saving surgical time and reducing postoperative complications. The aim of the present meta-analysis was to compare surgical time, postoperative complications and other parameters between them in for the open thyroidectomy procedure. Studies were retrieved from MEDLINE, Cochrane Library, EMBASE and ISI Web of Science until December 2015. All the randomized controlled trials (RCTs) comparing Harmonic scalpel and LigaSure during open thyroidectomy were selected. Following data extraction, statistical analyses were performed. Among the 24 studies that were evaluated for eligibility, 7 RCTs with 981 patients were included. The Harmonic scalpel significantly reduced surgical time compared with LigaSure techniques (8.79 min; 95% confidence interval, -15.91 to -1.67; P=0.02). However, no significant difference was observed for the intraoperative blood loss, postoperative blood loss, duration of hospital stay, thyroid weight and serum calcium level postoperatively in either group. The present meta-analysis indicated superiority of Harmonic Scalpel only in terms of surgical time compared with LigaSure hemostasis techniques in open thyroid surgery.
Collapse
Affiliation(s)
- Arun Upadhyaya
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Heping, Tianjin 300052, P.R. China
| | - Tianpeng Hu
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Heping, Tianjin 300052, P.R. China
| | - Zhaowei Meng
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Heping, Tianjin 300052, P.R. China
| | - Xue Li
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Heping, Tianjin 300052, P.R. China
| | - Xianghui He
- Department of General Surgery, Tianjin Medical University General Hospital, Heping, Tianjin 300052, P.R. China
| | - Weijun Tian
- Department of General Surgery, Tianjin Medical University General Hospital, Heping, Tianjin 300052, P.R. China
| | - Qiang Jia
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Heping, Tianjin 300052, P.R. China
| | - Jian Tan
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Heping, Tianjin 300052, P.R. China
| |
Collapse
|
14
|
Çiftçi F. The comparison of the harmonic focus shears device with conventional clamp binding in total thyroidectomy. Int J Clin Exp Med 2015; 8:19266-19273. [PMID: 26770563 PMCID: PMC4694463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Accepted: 09/30/2015] [Indexed: 06/05/2023]
Abstract
AIM Harmonic Focus (HF) is an ultrasonic device developed most recently for thyroid surgery. The aim of this study was to compare the surgical completeness and outcome of total thyroidectomy in two patient groups. One group was treated by HF and one by Conventional Dissection (CD). METHODS Total thyroidectomy was performed in 38 patients with CD, and in 38 patients with HF. RESULTS When compared to conventional haemostasis, a reduction was observed in the duration of surgery in the HF group, and the amount of blood loss was reduced by 29%, and 46%, respectively. The number of intraoperative device changes was decreased by 70%. The utilisation of special materials to obtain haemostasis was also significantly decreased. HF was found to be as safe as the conventional haemostasis technique. CONCLUSIONS Our study has demonstrated the beneficial effects and relative safety of HF in thyroid surgery. Further studies are needed about the financial benefits provided by reductions in human resources, and in materials employed for haemostasis.
Collapse
Affiliation(s)
- Fatih Çiftçi
- Vocational School of Health Services, Istanbul Gelisim University Avcılar, Istanbul, Turkey
| |
Collapse
|
15
|
Hahn CH, Trolle W, Sørensen CH. Harmonic focus in thyroidectomy for substernal goiter. Auris Nasus Larynx 2015; 42:311-7. [DOI: 10.1016/j.anl.2014.12.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 12/06/2014] [Accepted: 12/29/2014] [Indexed: 11/30/2022]
|
16
|
Kawabata R, Takiguchi S, Kimura Y, Imamura H, Fujita J, Tamura S, Fujitani K, Kishi K, Yamamoto K, Fujiwara S, Kurokawa Y, Mori M, Doki Y. A randomized phase II study of the clinical effects of ultrasonically activated coagulating shears (Harmonic scalpel) in open gastrectomy for gastric cancer. Surg Today 2015. [PMID: 26198895 DOI: 10.1007/s00595-015-1213-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
PURPOSE The Harmonic Ace ultrasonic scalpel has been popular in abdominal surgery; however, only a few clinical studies have evaluated the efficacy of this device in radical open gastrectomy for gastric cancer. METHODS The present study was designed as a multicenter, prospective, randomized, controlled trial. Patients with resectable gastric cancer were randomly assigned to gastrectomy using the Harmonic scalpel or conventional monopolar electrosurgery. RESULTS A total of 248 patients were enrolled, and 123 patients were included in the Harmonic group and 114 patients were included in the conventional group. The demographics of the patients were well balanced between the groups. There was no significant difference in the length of the operation from skin incision to resection of the gastric specimen (141 ± 36 min in the Harmonic group vs. 147 ± 13 min in the conventional group; p = 0.276) nor in the amount of blood lost (365 ± 293 vs. 336 ± 272 mL; p = 0.434). There was also no significant difference in the incidence of surgical complications or the post-surgical hospital stay between the groups. CONCLUSION The Harmonic scalpel procedure was not superior to the conventional monopolar electrosurgery with regard to reducing the length of the operation, blood loss, postoperative complications, or postoperative hospital stay in radical open gastrectomy.
Collapse
Affiliation(s)
- Ryohei Kawabata
- Department of Surgery, Osaka Rosai Hospital, Osaka, Japan.,Department of Surgery, Sakai City Hospital, Osaka, Japan
| | - Shuji Takiguchi
- Department of Gastroenterological Surgery, Osaka University Graduate School of Medicine, Osaka, Japan.
| | - Yutaka Kimura
- Department of Surgery, Sakai City Hospital, Osaka, Japan
| | - Hiroshi Imamura
- Department of Surgery, Toyonaka Municipal Hospital, Osaka, Japan
| | | | | | | | - Kentaro Kishi
- Department of Surgery, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka, Japan
| | | | - Shinichi Fujiwara
- Department of Gastroenterological Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Yukinori Kurokawa
- Department of Gastroenterological Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Masaki Mori
- Department of Gastroenterological Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Yuichiro Doki
- Department of Gastroenterological Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
17
|
Ren ZH, Xu JL, Fan TF, Ji T, Wu HJ, Zhang CP. The Harmonic Scalpel versus Conventional Hemostasis for Neck Dissection: A Meta-Analysis of the Randomized Controlled Trials. PLoS One 2015; 10:e0132476. [PMID: 26161897 PMCID: PMC4498925 DOI: 10.1371/journal.pone.0132476] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Accepted: 06/15/2015] [Indexed: 11/18/2022] Open
Abstract
Objective Neck dissection is the most definitive and effective treatment for head and neck cancer. This systematic review aims to compare the efficacy and surgical outcomes of neck dissection between the harmonic scalpel and conventional surgical techniques and conduct a quantitative meta-analysis of the randomized trials. Methods Randomized controlled trials (RCTs) were identified from the major electronic databases (MEDLINE, EMBASE and Cochrane Library) using the keywords ‘‘harmonic scalpel’’ and ‘‘neck dissection,’’ and a quantitative meta-analysis was conducted. The operative time and intraoperative bleeding were the primary outcome measures, and other parameters assessed included the drainage fluid volume and length of hospital stay. Results Seven trials that met the inclusion criteria included 406 neck dissection cases (201 in the harmonic scalpel group). Compared with conventional surgical techniques, the HS group had an operative time that was significantly reduced by 29.3 minutes [mean difference: -29.29; 95% CI = (-44.26, -14.32); P=0.0001], a reduction in intraoperative bleeding by 141.1 milliliters [mean difference: -141.13; 95% CI = (-314.99, 32.73); P=0.11], and a reduction in drainage fluid volume by 64.9 milliliters [mean difference: -64.86; 95% CI = (-110.40, -19.32); P=0.005] , but it is not significant after removal of studies driving heterogeneity. There was no significant difference in the length of the hospital stay [mean difference: -0.21; 95% CI = (-0.48, 0.07); P=0.14]. Conclusion This systematic review showed that using the harmonic scalpel for neck dissection significantly reduces the operative time and drainage fluid volume and that it is not associated with an increased length of hospital stay or perioperative complications. Therefore, the harmonic scalpel method is safe and effective for neck dissection. However, the statistical heterogeneity was high. Further studies are required to substantiate our findings.
Collapse
Affiliation(s)
- Zhen-Hu Ren
- Department of Oral and Maxillofacial & Head and Neck Oncology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jian-Lin Xu
- Department of Respiratory Medicine, Shanghai chest hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Teng-Fei Fan
- Department of Oral and Maxillofacial Surgery, Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Tong Ji
- Department of Oral and Maxillofacial & Head and Neck Oncology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Han-Jiang Wu
- Department of Oral and Maxillofacial Surgery, The Second Xiangya Hospital of Central South University, Changsha, China
| | - Chen-Ping Zhang
- Department of Oral and Maxillofacial & Head and Neck Oncology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- * E-mail:
| |
Collapse
|
18
|
Villar del Moral JM, Soria Aledo V, Colina Alonso A, Flores Pastor B, Gutiérrez Rodríguez MT, Ortega Serrano J, Parra Hidalgo P, Ros López S. Clinical Pathway for Thyroidectomy. Cir Esp 2015; 93:283-99. [PMID: 25732107 DOI: 10.1016/j.ciresp.2014.11.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2014] [Revised: 11/17/2014] [Accepted: 11/29/2014] [Indexed: 12/14/2022]
Abstract
Clinical pathways are care plans applicable to patient care procedures that present variations in practice and a predictable clinical course. They are designed not as a substitute for clinical judgment, but rather as a means to improve the effectiveness and efficiency of the procedures. This clinical pathway is the result of a collaborative work of the Sections of Endocrine Surgery and Quality Management of the Spanish Association of Surgeons. It attempts to provide a framework for standardizing the performance of thyroidectomy, the most frequently performed operation in endocrine surgery. Along with the usual documents of clinical pathways (temporary matrix, variance tracking and information sheets, assessment indicators and a satisfaction questionnaire) it includes a review of the scientific evidence around different aspects of pre, intra and postoperative management. Among others, antibiotic and antithrombotic prophylaxis, preoperative preparation in hyperthyroidism, intraoperative neuromonitoring and systems for obtaining hemostasis are included, along with management of postoperative hypocalcemia.
Collapse
Affiliation(s)
- Jesús María Villar del Moral
- Sección de Cirugía Endocrina de la Asociación Española de Cirujanos, Servicio de Cirugía General, Hospital Universitario Virgen de las Nieves, Granada, España.
| | - Víctor Soria Aledo
- Sección de Gestión de Calidad de la Asociación Española de Cirujanos, Servicio de Cirugía General, Hospital Universitario Morales Meseguer, Murcia, España
| | - Alberto Colina Alonso
- Sección de Gestión de Calidad de la Asociación Española de Cirujanos, Servicio de Cirugía General, Hospital Universitario de Cruces, Baracaldo, Vizcaya, España
| | - Benito Flores Pastor
- Sección de Gestión de Calidad de la Asociación Española de Cirujanos, Servicio de Cirugía General, Hospital Universitario Morales Meseguer, Murcia, España
| | - María Teresa Gutiérrez Rodríguez
- Sección de Cirugía Endocrina de la Asociación Española de Cirujanos, Servicio de Cirugía General, Hospital Universitario de Basurto, Bilbao, España
| | - Joaquín Ortega Serrano
- Sección de Cirugía Endocrina de la Asociación Española de Cirujanos, Servicio de Cirugía General, Hospital Clínico Universitario de Valencia, Valencia, España
| | - Pedro Parra Hidalgo
- Sección de Gestión de Calidad de la Asociación Española de Cirujanos, Consejería de Sanidad de la Región de Murcia, Murcia, España
| | - Susana Ros López
- Sección de Cirugía Endocrina de la Asociación Española de Cirujanos, Servicio de Cirugía General, Hospital Universitario Arnau de Vilanova, Lérida, España
| |
Collapse
|
19
|
Choi MG, Oh SJ, Noh JH, Sohn TS, Kim S, Bae JM. Ultrasonically activated shears versus electrocautery in open gastrectomy for gastric cancer: a randomized controlled trial. Gastric Cancer 2015; 17:556-61. [PMID: 24048759 DOI: 10.1007/s10120-013-0301-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2013] [Accepted: 08/30/2013] [Indexed: 02/07/2023]
Abstract
BACKGROUND Use of ultrasonically activated shears (UAS) is gaining popularity in open surgery but without concrete evidence. We conducted a prospectively randomized study to assess the efficacy of ultrasonic dissection in open gastrectomy for gastric cancer. METHODS Patients with gastric cancer who were to undergo gastrectomy with D2 lymph node dissection were enrolled and assigned to either the conventional surgery group (n = 125) or the UAS group (n = 128). RESULTS The mean operating time was significantly reduced in the UAS group (89.3 ± 15.6 min) when compared to the conventional group (97.8 ± 17.2 min; p < 0.001). However, we did not find any significant difference in operative blood loss, the amount of postoperative abdominal drainage, or the rate of postoperative complications between the groups. A multivariate analysis for operating time revealed that the use of UAS, female gender and BMI less than 25 were significantly associated with reduced operating time. The operating time was significantly longer in the conventional group than in the UAS group (B 7.786; 95 % CI 4.103-11.468; p < 0.001). In the subgroup analysis, the use of UAS significantly reduced the operating time, especially in male patients, regardless of the BMI status. CONCLUSIONS The use of UAS in gastrectomy for gastric cancer was a safe and efficient method, especially in terms of reducing operating time for male patients.
Collapse
Affiliation(s)
- Min-Gew Choi
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-gu, Seoul, 135-710, Korea
| | | | | | | | | | | |
Collapse
|
20
|
Radiofrequency dissection versus 'knot tying' in conventional total thyroidectomy. The Journal of Laryngology & Otology 2014; 128:818-23. [PMID: 25171125 DOI: 10.1017/s0022215114001789] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE To evaluate the safety and effectiveness of radiofrequency dissection in conventional 'open' total thyroidectomy. METHODS Thirty-nine patients scheduled for conventional total thyroidectomy were included in a prospective randomised study. Patients were randomly assigned to one of two groups: a radiofrequency dissection method was used in one group, and a knot tying technique was used in the other. RESULTS Significantly fewer surgical instruments and materials were required for the radiofrequency dissection group than the knot tying group (p < 0.01). There were no significant differences between the two groups in mean operative time, blood loss, post-operative drainage and pain, recurrent palsy, and hypocalcaemia (p > 0.05). CONCLUSION Radiofrequency dissection is a safe alternative to the knot tying technique, and enables a significant reduction in the number of surgical instruments required for the operation.
Collapse
|
21
|
Bulus H, Tas A, Coskun A, Kucukazman M. Evaluation of two hemorrhoidectomy techniques: Harmonic scalpel and Ferguson's with electrocautery. Asian J Surg 2014; 37:20-3. [PMID: 23726831 DOI: 10.1016/j.asjsur.2013.04.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2012] [Revised: 01/21/2013] [Accepted: 04/03/2013] [Indexed: 11/25/2022] Open
|
22
|
Iorgulescu R, Badanoiu D, Lupu A, Cucu C, Niculescu D, Iordache N. Lessons learned from the first 50 thyroidectomies with Harmonic Focus Curved Shears - technical note. J Med Life 2014; 7 Spec No. 4:54-61. [PMID: 27057249 PMCID: PMC4813618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Precise and safe hemostasis is necessary for successful thyroid surgery. In this respect, the advent of the ultrasonic surgical device Harmonic Focus Curved Shears (HFCS) from Ethicon Endo-Surgery constituted a major progress in the domain by its multiple capabilities of dissection, grasping, vessel sealing and transecting. The paper presents the initial experience of 50 cases with this device of a surgical team with special interest in endocrine surgery, mostly thyroid and parathyroid. The thyroid conditions for which surgery was indicated were: diffuse toxic goiter in 8 patients; multinodular toxic and nontoxic goiter in 30 patients; autonomous nodule in 2 patients; 2 patients with benign nodules at fine needle aspiration biopsy (FNAB); 4 patients with nodules positive for carcinoma at FNAB, among them 2 with unilateral cervical lymph nodes enlargement; 4 patients with highly suspect nodule on FNAB. The types of surgery performed were 4 hemithyroidectomies and 46 total thyroidectomies, 2 in association with unilateral functional neck dissections. We had 4 intraoperative hemorrhagic incidents, all in the first 15 cases and imputable to lack of expertise and improper usage of the device. We registered the following noticeable postoperative complications: 1 cervical hematoma from an arteriolar source in sternothyroid muscle demanding prompt reintervention; 8 hypocalcemias and 2 vocal cord paresis, none of which permanent. We remarked several advantages with HFCS: no necessity of changing instruments, fluentness of the intervention and more comfort for the operating team, reduced operating time, safe hemostasis. Some important tips and tricks with the usage of the instrument are presented.
Collapse
Affiliation(s)
- R Iorgulescu
- Emergency Clinical Hospital “Sf. Ioan” Bucharest
| | - D Badanoiu
- Emergency Clinical Hospital “Sf. Ioan” Bucharest
| | - A Lupu
- Emergency Clinical Hospital “Sf. Ioan” Bucharest
| | - C Cucu
- National Institute of Endocrinology “CI Parhon” Bucharest
| | - D Niculescu
- National Institute of Endocrinology “CI Parhon” Bucharest
| | - N Iordache
- Emergency Clinical Hospital “Sf. Ioan” Bucharest
| |
Collapse
|
23
|
Contin P, Gooßen K, Grummich K, Jensen K, Schmitz-Winnenthal H, Büchler MW, Diener MK. ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery--the ENERCON systematic review and network meta-analysis. Langenbecks Arch Surg 2013; 398:1039-56. [PMID: 24240627 DOI: 10.1007/s00423-013-1137-7] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2013] [Accepted: 10/25/2013] [Indexed: 11/28/2022]
Abstract
PURPOSE Energized vessel-sealing systems have been proposed to save operation time and reduce post-operative complications. The aim of the present systematic review was to compare operation time and postoperative morbidity for ultrasonic and electrothermal bipolar-activated devices with conventional hemostasis techniques and with each other in open thyroidectomy. METHODS A systematic literature search (MEDLINE, Cochrane Library, EMBASE and ISI Web of Science) was performed to identify randomised controlled trials (RCTs) comparing conventional hemostasis techniques, ultrasonic devices (Harmonic® scalpel) and/or electrothermal bipolar-activated vessel sealing systems (Ligasure®) during open thyroidectomy. For the primary endpoint (operation time), a network meta-analysis with Bayesian random effects model was performed. Pairwise meta-analyses with random effects were calculated for primary and secondary endpoints. RESULTS One hundred sixteen publications were evaluated for eligibility; 35 RCTs (4,061 patients) were included. There was considerable methodological and clinical heterogeneity of included trials. The Harmonic scalpel significantly reduced operation time compared with conventional techniques (22.26 min, 22.7 min in the inconsistency model). The use of Ligasure significantly reduced operation time in total thyroidectomy (13.84 min in the consistency model, 12.18 min in the inconsistency model). In direct comparison, operations with the Harmonic scalpel were faster than with Ligasure (8.42 min in the consistency model, 2.45 min in the inconsistency model). The rates of recurrent nerve palsy and postoperative hypocalcaemia did not significantly differ in the intervention groups. CONCLUSIONS This meta-analysis shows superiority of ultrasonic devices in terms of operation time compared with conventional hemostasis techniques in thyroid surgery, with no detriment to safety outcomes.
Collapse
Affiliation(s)
- Pietro Contin
- Department of General-, Visceral- and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | | | | | | | | | | | | |
Collapse
|
24
|
Fitz-Gerald AL, Tan J, Chan KW, Polyakov A, Edwards GN, Najjar H, Tsaltas J, Vollenhoven B. Comparison of ultrasonic shears and traditional suture ligature for vaginal hysterectomy: randomized controlled trial. J Minim Invasive Gynecol 2013; 20:853-7. [PMID: 24183277 DOI: 10.1016/j.jmig.2013.05.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2013] [Revised: 05/18/2013] [Accepted: 05/23/2013] [Indexed: 10/26/2022]
Abstract
STUDY OBJECTIVE To compare operating time, intraoperative blood loss, postoperative analgesia, and length of hospital stay using ultrasonic shears vs traditional suture ligature in vaginal hysterectomy. DESIGN Randomized controlled trial (Canadian Task Force classification I). SETTING Gynecology units within a single health network, university hospital. PATIENTS Forty women requiring vaginal hysterectomy because of benign disease. INTERVENTIONS Vaginal hysterectomy performed using either ultrasonically activated shears (USS) or traditional suture ligatures. MEASUREMENTS AND MAIN RESULTS Twenty-one patients were randomized to the USS arm, and 19 patients to the traditional suture ligature arm. Patient characteristics were comparable. Mean (SD) hysterectomy time and was similar in both the USS and traditional arms, 28.66 (4.0) minutes vs 32.37 (3.18) minutes (p = .47), as was total operating time, 97.38 (8.9) minutes vs 91.63 (7.69) minutes (p = .63). Operative blood loss was significantly decreased in the USS group: 62.63 (12.46) mL vs 136.05 (21.54) mL (p = .006). There was, however, no significant change in hemoglobin concentration between the 2 groups: 19.53 (1.79) g/L vs -16.72 (2.5) g/L. There was no significant difference in mean oxycodone use: 9.29 (2.66) mg vs 8.06 (3.19) mg (p = .77). Length of hospital stay was similar in both groups: 58.98 (3.27) hours vs 60.05 (6.48) hours (p = .88). There was no significant difference in overall complication rates between the groups. CONCLUSION Although the Harmonic scalpel system, compared with the traditional suture ligation method, seems to be a safe alternative for securing the pedicles in vaginal hysterectomy, it offers no benefit insofar as operative time, reduction in clinically significant blood loss, and analgesic requirements.
Collapse
|
25
|
Sista F, Abruzzese V, Schietroma M, Cecilia EM, Mattei A, Amicucci G. New harmonic scalpel versus conventional hemostasis in right colon surgery: a prospective randomized controlled clinical trial. Dig Surg 2013; 30:355-61. [PMID: 24080607 DOI: 10.1159/000354864] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2013] [Accepted: 08/02/2013] [Indexed: 12/12/2022]
Abstract
BACKGROUND The Harmonic Scalpel (HS) is a device that uses vibrations to coagulate and cut tissues simultaneously. Its advantages are represented by minimal lateral thermal tissue damage, less smoke formation, no neuromuscular stimulation and no transmission of electricity to the patient. METHODS A total of 211 consecutive patients (113 men, 98 women; mean age 64 years) undergoing hemicolectomy for cancer of the right colon were divided into two groups, namely those in whom the operation was performed using a new HS handpiece (NHS; 108 patients) and those assigned to conventional hemostasis (CH; 103 patients). The two surgical groups were compared regarding patients' age and sex, tumor size, location, histotype and local invasiveness assessed by American Joint Cancer Committee stage, operative time, fluid content in the suction balloon (drainage volume) during the first 1-3 days after surgery, hospital stay and complications. RESULTS Ultrasonic energy delivered through an HS has been shown to be safe and to produce minimal damage to the surrounding tissues because of its minimal heat production. Electrical devices allow hemostatic control in vessels up to 3 mm in diameter, while HS can coagulate vessels up to 5 mm in diameter; thus, HS allows not only better control of bleeding but also of lymphorrhea. In fact, the amount of fluid collected in the drainage was significantly lower in the NHS group compared to the CH group. Protein depletion influences the patient's regenerative capacity and thus also the occurrence of complications and recovery time. CONCLUSION NHS is a useful device in colon surgery; it facilitates surgical maneuvers and reduces operative times and blood and lymphatic losses, allowing satisfactory maintenance of protein storage. This results in a lower incidence of complications and faster recovery by patients.
Collapse
Affiliation(s)
- Federico Sista
- Dipartimento di Scienze Cliniche Applicate e Biotecnologie, University of L'Aquila, L'Aquila, Italy
| | | | | | | | | | | |
Collapse
|
26
|
Garas G, Okabayashi K, Ashrafian H, Shetty K, Palazzo F, Tolley N, Darzi A, Athanasiou T, Zacharakis E. Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies. Thyroid 2013; 23:1138-50. [PMID: 23470035 DOI: 10.1089/thy.2012.0588] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
BACKGROUND Energy-based hemostatic devices are increasingly being used in thyroid surgery. However, there are several limitations with regard to the existing evidence and a paucity of guidelines on the subject. The goal of this review is to employ the novel evidence synthesis technique of a network meta-analysis to assess the comparative effectiveness of surgical technologies in thyroid surgery and contribute to enhanced governance in the field of thyroid surgery. METHODS Articles published between January 2000 and June 2012 were identified from Embase, Medline, Cochrane Library, and PubMed databases. Randomized controlled trials of any size comparing the use of ultrasonic coagulation (harmonic scalpel) or Ligasure either head-to-head or against the "clamp-and-tie" technique were included. Two reviewers independently critically appraised and extracted the data from each study. The number of patients who experienced postoperative events was extracted in dichotomous format or continuous outcomes. Odds ratios were calculated by a Bayesian network meta-analysis, and metaregression was used for pair-wise comparisons. Indirect and direct comparisons were performed and inconsistency was assessed. RESULTS Thirty-five randomized controlled trials with 2856 patients were included. Ultrasonic coagulation ranked first (followed by Ligasure and then clamp-and-tie) with the lowest risk of postoperative hypoparathyroidism (odds ratio 1.43 [95% confidence interval (CI) 0.77-2.67] and 0.70 [CI 0.43-1.13], ultrasonic coagulation vs. Ligasure and ultrasonic coagulation vs. clamp-and-tie, respectively), least blood loss (-0.25 [CI -0.84 to -0.35] and -1.22 [CI -1.85 to -0.59]), and drain output (0.28 [CI -0.35 to -0.91] and -0.36 [CI -0.70 to -0.03]). From a health technology viewpoint, ultrasonic coagulation was associated with the shortest operative time (-0.66 [CI -1.17 to -0.14] and -1.29 [CI -1.59 to -1.00]) and hospital stay (-0.28 [CI -0.78 to 0.22] and -0.56 [CI -1.28 to 0.15]). The only exception occurs with the clinically important complication of recurrent laryngeal nerve paralysis, where the reverse trend applies (1.36 [CI 0.25-7.46] and 1.74 [CI 0.94-3.26]). CONCLUSIONS The comparative effectiveness of ultrasonic coagulation in thyroid surgery outcomes seems superior to other techniques with the exception of recurrent laryngeal nerve injury. This network meta-analysis, one of a handful in a surgical field, offers preliminary and robust evidence to guide clinical decisions and policy makers to adopt safer thyroid operations.
Collapse
Affiliation(s)
- George Garas
- 1 Department of Otorhinolaryngology and Head & Neck Surgery, Imperial College London , London, United Kingdom
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
The impact of the Harmonic FOCUS™ on complications in thyroid surgery: a prospective multicenter study. Updates Surg 2013; 65:295-9. [DOI: 10.1007/s13304-013-0223-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2012] [Accepted: 06/21/2013] [Indexed: 10/26/2022]
|
28
|
Dean A, Alamillos F, Centella I, García-Álvarez S. Neck dissection with the harmonic scalpel in patients with squamous cell carcinoma of the oral cavity. J Craniomaxillofac Surg 2013; 42:84-7. [PMID: 23680491 DOI: 10.1016/j.jcms.2013.02.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2012] [Revised: 02/24/2013] [Accepted: 02/25/2013] [Indexed: 12/17/2022] Open
Abstract
UNLABELLED Our purpose was to evaluate the use of the Harmonic scalpel in neck dissections. MATERIAL AND METHODS We conducted a randomized prospective intervention study to compare the Harmonic scalpel (32 patients) with the conventional technique (31 patients). RESULTS Operative time was lowered by 64 min (p < 0.001) and 7.5 min (p = 0.367); blood lost during surgery was lowered by 80.5 ml (p < 0.001) and 76.6 ml (p < 0.001); the length of time the drains were kept in place was lowered by 1.3 days (p < 0.001) and 1.5 days (p < 0.01); and the volume of drainage was lower by 228.7 ml (p < 0.001) and 187.6 ml (p < 0.01) in selective and comprehensive neck dissections respectively in patients treated with the Harmonic scalpel. CONCLUSIONS The Harmonic scalpel shortens operative time in selective dissections. It reduces blood loss during surgery; time drains are kept in place and the amount of drainage in comprehensive and selective neck dissections.
Collapse
Affiliation(s)
- Alicia Dean
- Department of Oral and Maxillofacial Surgery (Head: A. Dean), "Reina Sofía" University Hospital, Córdoba, Spain.
| | - Francisco Alamillos
- Department of Oral and Maxillofacial Surgery (Head: A. Dean), "Reina Sofía" University Hospital, Córdoba, Spain
| | - Inmaculada Centella
- Department of Oral and Maxillofacial Surgery (Head: A. Dean), "Reina Sofía" University Hospital, Córdoba, Spain
| | - Sandra García-Álvarez
- Department of Oral and Maxillofacial Surgery (Head: A. Dean), "Reina Sofía" University Hospital, Córdoba, Spain
| |
Collapse
|
29
|
Lang BHH, Yih PCL, Hung GKY. Does using an energized device in open thyroidectomy reduce complications? J Surg Res 2013; 181:e23-9. [DOI: 10.1016/j.jss.2012.06.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2012] [Revised: 05/12/2012] [Accepted: 06/04/2012] [Indexed: 01/03/2023]
|
30
|
[Efficacy and budget impact of the Focus harmonic scalpel compared to the ACS-14C device in total thyroidectomy due to multinodular goitre. A prospective randomised study]. Cir Esp 2013; 91:664-71. [PMID: 23473435 DOI: 10.1016/j.ciresp.2012.11.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Revised: 11/19/2012] [Accepted: 11/21/2012] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To analyse the potential advantages and outcomes of the new Harmonic Focus™ (Focus) device compared to the Harmonic Scalpel™ ACS-14C in benign thyroid surgery. METHODS A controlled randomised study was conducted in which the Focus was compared to former ACS-14C device in patients undergoing total thyroidectomy for multinodular goitre. The primary endpoint was time of surgery. The secondary endpoints were time of use of the device, number of ligatures, blood loss, hypocalcaemia, laryngeal nerve impairment, postoperative pain and quality of life. RESULTS Two groups of patients were included, 26 patients in group i (ACS-14C) and 28 in group ii (Focus). There was a 16% reduction in surgical time (78.7 ± 22.01 vs. 66 ± 17.0 min; P<.05) between group i and ii respectively. The Focus was used longer than ACE-14S, both in absolute time (26.0 ± 7.7 vs. 10.0 ± 3.5 minutes; P<.05), as well as in relative time (40.7 ± 11.8% vs. 13.1 ± 4.1%; P<.05), respectively. A significant reduction in number of ligatures in Focus patients was also observed (0,3 ± 0,8 vs. 2.9 ± 3.6; P<.05). Budget impact analysis showed an additional average savings per procedure of 179.74 €. CONCLUSIONS Focus ergonomics significantly improved the operation time in thyroidectomy causing a positive impact on the budget. Focus also adds further benefits to those previously achieved by Harmonic technology, and it is by itself more cost-effective in total thyroidectomy than ACS-14C.
Collapse
|
31
|
Lang BHH, Ng SH, Lau LL, Cowling BJ, Wong KP. A Systematic Review and Meta-analysis Comparing the Efficacy and Surgical Outcomes of Total Thyroidectomy Between Harmonic Scalpel Versus Ligasure. Ann Surg Oncol 2013; 20:1918-26. [DOI: 10.1245/s10434-012-2849-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2012] [Indexed: 11/18/2022]
|
32
|
Development of a canine model for recurrent laryngeal injury by harmonic scalpel. Lab Anim Res 2012; 28:223-8. [PMID: 23326282 PMCID: PMC3542380 DOI: 10.5625/lar.2012.28.4.223] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2012] [Revised: 10/19/2012] [Accepted: 10/25/2012] [Indexed: 11/30/2022] Open
Abstract
Various energy devices had been used in thyroid surgery. Aim of study is to develop canine model for recurrent laryngeal nerve injury by harmonic scalpel and to evaluate feasibility of using this model for evaluating the safety use of harmonic scalpel during thyroid surgery. Nine dogs were divided into 3 groups according to distance between harmonic scalpel application and recurrent laryngeal nerve; group 1 (1 mm), 2 (2 mm), and 3 (3 mm). Vocal cord function was assessed pre- and postoperatively using video laryngoscopy. Harmonic scalpel was applied adjacent to left recurrent laryngeal nerve and, two weeks later, right recurrent laryngeal nerve at assigned distances. Recurrent laryngeal nerves were evaluated for subacute and acute morphologic changes. Laryngoscopy demonstrated 3 abnormal vocal cords in group 1, 1 in group 2, and no in group 3 (P=0.020). Subacute histologic changes were observed in nerves with abnormal function. Acute histologic changes were observed 5/8 (62.5%) in group 1, 1/7 (14.3%) in group 2, and not in group 3. We developed canine model for recurrent laryngeal injury. The functional outcomes matched with the histologic changes. These warrant further study to determine the safety margin for energy device in vicinity of recurrent laryngeal nerve.
Collapse
|
33
|
Total thyroidectomy for non-toxic multinodular goiter with versus without the use of harmonic FOCUS dissecting shears - a prospective randomized study. Wideochir Inne Tech Maloinwazyjne 2012; 7:268-74. [PMID: 23362426 PMCID: PMC3557734 DOI: 10.5114/wiitm.2011.30675] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2012] [Revised: 04/23/2012] [Accepted: 05/27/2012] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Thyroidectomy is among the most commonly performed procedures involving the endocrine glands and the development of advanced surgical methods combined with a strife for performing the operation in a manner that is minimally invasive for the patient has considerably increased the need for instruments that would limit surgical trauma. AIM To compare of the outcomes of total thyroidectomy operations with and without the use of ultrasonic harmonic FOCUS dissecting shears. MATERIAL AND METHODS Eighty-two patients with a bilateral, non-toxic multinodular goiter were randomized to two groups of 41 patients each. Total thyroidectomy was performed in each patient. In the clip-ligation group (CL-G), during thyroidectomy, the superior thyroid vessels were clipped and bipolar coagulation was used to secure smaller vessels, whereas in the harmonic FOCUS group (HF-G), a harmonic device was used to dissect and divide all the thyroid vessels. The statistical analysis included the mean operative time, blood loss, postoperative morbidity and cost-effectiveness. RESULTS HF-G vs. CL-G operations were shorter (45.4 ±8.7 min vs. 64.5 ±14.2 min; p < 0.001), characterized by a lower mean blood loss (29.9 ±9.8 ml vs. 56.8 ±11.0 ml; p < 0.001) and appeared to be more cost-effective (666.2 ±37.5 EUR vs. 718.0 ±69.2 EUR; p < 0.01). No major complications were observed in both groups. CONCLUSIONS In total thyroidectomy operations, the harmonic FOCUS is safe and facilitates dissection, allowing for a significant decrease in operative time. Other benefits include lower blood loss and a slightly decreased cost of the procedure.
Collapse
|
34
|
THE HARMONIC STUDY: COST-EFFECTIVENESS EVALUATION OF THE USE OF THE ULTRASONIC SCALPEL IN TOTAL THYROIDECTOMY. Int J Technol Assess Health Care 2012; 28:259-64. [DOI: 10.1017/s0266462312000220] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background: Total thyroidectomy (TT) can be performed either with the traditional technique or using the ultrasound scalpel. Here, the use of the ultrasound scalpel is investigated in order to assess cost-effectiveness from an hospital, third party payer and societal perspective.Methods: A randomized controlled trial was conducted at the University Hospital A. Gemelli in Rome. Data refer to 198 patients, randomized to either surgery with the ultrasound scalpel (n = 96) or traditional (n = 102) and followed for 3 months after hospital discharge. Operation time (OT) and resource consumption were recorded. Main clinical outcome investigated was quality of life (evaluated with EQ-5D).Results: A shorter operation time (traditional: 76.36 vs ultrasound: 54.16 minutes, p < 0.001) was observed. 3 months after surgery, differences in QoL were significant (0.91 vs 0.84, p = 0.002). Concerning the hospital perspective, ultrasound scalpel allows savings of 119 EUR per patient. From a societal perspective, ultrasound scalpel is also related to lower medical resource consumption during a 3 month follow-up after discharge (traditional: 129.03 EUR vs ultrasound: 107.82 EUR) and lower non-medical resource utilization (transport/hotels costs traditional:535.51 EUR vs ultrasound: 342.77 EUR. No statistical difference was found in productivity losses up to 3 months (traditional: 377.71 EUR vs ultrasound: 385.51 EUR).Conclusion: Allowing an overall saving of 325.36 EUR per patient, Ultrasound scalpel should be adopted for TT procedures in the “A.Gemelli” University hospital.
Collapse
|
35
|
Diener MK, Seiler CM, von Frankenberg M, Rendel K, Schüle S, Maschuw K, Riedl S, Rückert JC, Eckmann C, Scharlau U, Ulrich A, Bruckner T, Knaebel HP, Rothmund M, Büchler MW. Vascular clips versus ligatures in thyroid surgery--results of a multicenter randomized controlled trial (CLIVIT Trial). Langenbecks Arch Surg 2012; 397:1117-26. [PMID: 22729718 DOI: 10.1007/s00423-012-0976-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2012] [Accepted: 06/11/2012] [Indexed: 12/26/2022]
Abstract
BACKGROUND New techniques using vascular clips or ultrasonically activated shears have been suggested to shorten operation time without compromising safety. The objective of the CLIVIT Trial was to compare ligatures with vascular clips for hemostasis in elective benign thyroid surgery. METHODS This multicenter, randomized, controlled, parallel group superiority trial was conducted in 13 German surgical centers. Patients scheduled for at least subtotal resection bilaterally were intraoperatively randomized. The primary endpoint was resection time. Secondary endpoints were the amount of postoperative bleeding, reoperation due to bleeding, wound infection, temporary (reversal within 12 months) and permanent (over 1 year) recurrent laryngeal nerve (RLN) paralysis, length of hospital stay, and safety. REGISTRATION ISRCTN 96901396. RESULTS Two hundred fifty patients were treated with ligatures and 241 with vascular clips. No differences in patients' baseline and surgical characteristics were observed. No difference was detected for mean resection time (clip 63.5 min ± 29.6, ligature 66.1 min ± 29.3, P = 0.258). Postoperative bleeding (mean 86 ml ± 93), reoperation due to bleeding (clips 4, ligature 2), wound infections (clips 4, ligature 4), postoperative hospital stay (mean 3.0 ± 1.9), and safety data also did not vary significantly. The rates of temporary and permanent RLN paralysis were 6.9 % (34/491) and 2.9 % (14/491), respectively. Not using a surgical drain (123 patients) was not associated with a higher rate of complications. CONCLUSION Vascular clips did not reduce the resection time. However, a 2.9 % rate of permanent RLN paralysis is of concern. Drains in elective surgery may be of no benefit.
Collapse
Affiliation(s)
- Markus K Diener
- Study Center of the German Surgical Society and Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Harmonic scalpel compared to conventional hemostasis in thyroid surgery. Indian J Surg 2012; 76:66-9. [PMID: 24799787 DOI: 10.1007/s12262-012-0627-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2011] [Accepted: 06/12/2012] [Indexed: 12/13/2022] Open
Abstract
The aim of this study was to determine whether conventional hemostasis (CH) or the harmonic scalpel (HS) results in shorter operative times for thyroidectomy and to evaluate the incidence of postoperative complications with each approach. In this study, 85 consecutive patients undergone open thyroidectomy were randomized into two groups: group CH (conventional hemostasis with classic technique of tying and knots, resorbable ligature, bipolar diathermy) and group HS (harmonic scalpel). Demographics, pathological characteristics, thyroid size, operative time, blood loss, and complications using the Student's t-test and χ (2)-test. The two groups were similar regarding age and sex. There were no intraoperative complications. There was no difference between the two techniques regarding the amount of blood loss for different procedures. No significant differences were found between the two groups concerning mean thyroid weight and mean hospital stay (2.2 days in HS vs. 3.7 in CH; P > 0.05). The mean operative time was significantly shorter in the HS group (47.2 min vs. 79.2 min; P < 0.001). Two (4.7 %) transient recurrent laryngeal nerve palsies were observed in the CH group and no one (0 %) in the HS group. No patient developed permanent palsy. Postoperative transient hypocalcemia occurred more frequently in the CH group (21/43, 48 % vs. 7/42, 16 %). In patients undergoing thyroidectomy, HS is a reliable and safe tool. Comparing with CH techniques, its use reduces operative times, postoperative pain, drainage volume, and transient hypocalcemia.
Collapse
|
37
|
Sista F, Schietroma M, Ruscitti C, De Santis G, De Vita F, Carlei F, Amicucci G. New Ultrasonic Dissector Versus Conventional Hemostasis in Thyroid Surgery: A Randomized Prospective Study. J Laparoendosc Adv Surg Tech A 2012; 22:220-4. [DOI: 10.1089/lap.2011.0266] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Federico Sista
- Department of Surgery, University of L'Aquila, L'Aquila, Italy
| | | | | | | | - Fabiola De Vita
- Department of Surgery, University of L'Aquila, L'Aquila, Italy
| | | | | |
Collapse
|
38
|
Kowalski LP, Sanabria A, Vartanian JG, Lima RA, Toscano de Mendonca UB, Roberto dos Santos C, Boldrini Júnior D, Barbalho de Mello LE, Pinto FP, Lehn CN, Correa LAC, Dedivitis RA, Guimarães AV, Pedruzzi PAG, Ramos GHA, Gonçalves AJ, Suehara AB, Kanda JL, de Castro Capuzzo R, Carlos de Oliveira J, Curado MP, Francisco de Góis Filho J, Fukuyama E, Beserra Júnior IM, Bentes de Carvalho Neto P, Carvalho AL. Total thyroidectomy with ultrasonic scalpel: A multicenter, randomized controlled trial. Head Neck 2012; 34:805-12. [DOI: 10.1002/hed.21815] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/04/2011] [Indexed: 11/10/2022] Open
|
39
|
Focus harmonic scalpel compared to conventional haemostasis in open total thyroidectomy: a prospective randomized trial. Int J Otolaryngol 2011; 2011:357195. [PMID: 22187563 PMCID: PMC3236473 DOI: 10.1155/2011/357195] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2011] [Accepted: 09/20/2011] [Indexed: 11/17/2022] Open
Abstract
The aim of this prospective randomized trial was to compare operative factors, postoperative outcomes and surgical complications of open total thyroidectomy when using the Harmonic Scalpel (HS) versus Conventional Haemostasis (CH). Methods. 100 consecutive patients underwent open total thyroidectomy were randomized into two groups: group CH (Conventional Haemostasis) and group HS (Harmonic Scalpel). We recorded the following: age, sex, pathology, thyroid volume, haemostatic technique, operative time, drainage volume, thyroid weight, postoperative pain, postoperative complications, and hospital stay. The results were analyzed using the Student's t test and χ2 test. Results. No significant difference was found between the two groups concerning mean thyroid weight and mean hospital stay. The mean operative time was significantly shorter in the HS group. The total drainage fluid volume was lower in HS group. Two (4%) transient recurrent laryngeal nerve palsies were observed in CH group and no one (0%) in the HS group. Postoperative transient hypocalcemia occurred more frequently in the CH group. HS group experienced significantly less postoperative pain at 24 and 48 hours. Conclusions. In patients undergoing thyroidectomy, HS is a reliable and safe tool. Comparing with CH techniques, its use reduces operative times, postoperative pain, drainage volume and transient hypocalcemia.
Collapse
|
40
|
Mourad M, Rulli F, Robert A, Scholtes JL, De Meyer M, De Pauw L. Randomized clinical trial on Harmonic Focus shears versus clamp-and-tie technique for total thyroidectomy. Am J Surg 2011; 202:168-74. [PMID: 21810497 DOI: 10.1016/j.amjsurg.2010.07.047] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2010] [Revised: 07/26/2010] [Accepted: 07/26/2010] [Indexed: 11/25/2022]
Abstract
BACKGROUND The Harmonic Focus is the last ultrasonic device designed for thyroid surgery. The aim is to assess its efficacy and safety compared with traditional dissection in a prospective randomized trial of total thyroidectomy procedures. METHODS Total thyroidectomy was performed in 34 patients using the Harmonic Focus, and in 34 patients using the clamp-and-tie technique. RESULTS In the Harmonic Focus group, relative reductions of 29% and 46% were observed in surgical time and blood loss, respectively. The number of intraoperative instrument exchanges also decreased by 70%, and use of specific materials required to achieve hemostasis decreased significantly. Safety was found to be similar in both patient groups. CONCLUSIONS Our study showed beneficial effects of Harmonic Focus use in thyroid surgery. Further studies therefore are needed to evaluate cost in the light of savings made in surgical time, materials needed for hemostasis, and human resources.
Collapse
Affiliation(s)
- Michel Mourad
- Department of Surgery, Surgery and Abdominal Transplantation Division, Cliniques Universitaires, St Luc, Université Catholique de Louvain, Hippocrate Ave., 10 1200 Brussels, Belgium.
| | | | | | | | | | | |
Collapse
|
41
|
Harmonic Focus™ versus “knot tying” during total thyroidectomy: a randomized trial. Updates Surg 2011; 63:277-81. [DOI: 10.1007/s13304-011-0099-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2011] [Accepted: 07/08/2011] [Indexed: 01/31/2023]
|
42
|
Satoi S, Yanagimoto H, Toyokawa H. Use of the new ultrasonically curved shear in pancreaticoduodenectomy for periampullary cancer. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2011; 18:609-14. [DOI: 10.1007/s00534-011-0370-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Sohei Satoi
- Department of Surgery; Kansai Medical University; 2-3-1 Shin-machi Hirakata Osaka 573-1191 Japan
| | - Hiroaki Yanagimoto
- Department of Surgery; Kansai Medical University; 2-3-1 Shin-machi Hirakata Osaka 573-1191 Japan
| | - Hideyoshi Toyokawa
- Department of Surgery; Kansai Medical University; 2-3-1 Shin-machi Hirakata Osaka 573-1191 Japan
| |
Collapse
|
43
|
Koch CA, Olsen SM, Martin EJ, Moore EJ. Ultrasonic shears in free-tissue transfer: increased efficiency and cost savings. Otolaryngol Head Neck Surg 2010; 144:201-5. [PMID: 21493416 DOI: 10.1177/0194599810391846] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE The harvest of some microvascular free flaps for head and neck reconstruction entails tedious and time-consuming dissection of multiple perforating vessels and/or muscular attachments. The objective of this study is to investigate the use of ultrasonic shears as a means to decrease operative time and increase surgical efficiency in the harvest of microvascular free flaps. STUDY DESIGN Prospective cohort study. SETTING Tertiary referral center. SUBJECTS AND METHODS A prospective study of all people undergoing fibula (FFF) or anterolateral thigh (ALT) free flap reconstruction of head and neck defects was conducted from October 1, 2005, through December 30, 2009. RESULTS There were 69 FFF and 39 ALT free flaps performed by a single surgeon during the study period. Ultrasonic shears were used in 53 (76.8%) FFF and 26 (80.6%) ALT free flaps, whereas traditional dissection techniques were used in 16 (23.2%) FFF and 13 (19.4%) ALT free flaps. The use of ultrasonic shears significantly decreased the harvest time of FFF and ALT free flaps an average of 14.5 and 16.3 minutes, respectively. The average cost savings associated with the use of ultrasonic shears was $492 for FFF and $543 for ALT free flaps compared to traditional dissections techniques. Similar rates of complications were observed when ultrasonic shears were used compared to traditional techniques. CONCLUSIONS The use of ultrasonic shears in the harvest of microvascular free flaps decreases operative time, leading to significantly decreased costs without an increased risk of complications compared to traditional dissection techniques.
Collapse
Affiliation(s)
- Cody A Koch
- Department of Otorhinolaryngology-Head and Neck Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA
| | | | | | | |
Collapse
|
44
|
Cirocchi R, D'Ajello F, Trastulli S, Santoro A, Di Rocco G, Vendettuoli D, Rondelli F, Giannotti D, Sanguinetti A, Minelli L, Redler A, Basoli A, Avenia N. Meta-analysis of thyroidectomy with ultrasonic dissector versus conventional clamp and tie. World J Surg Oncol 2010; 8:112. [PMID: 21176243 PMCID: PMC3022596 DOI: 10.1186/1477-7819-8-112] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2010] [Accepted: 12/23/2010] [Indexed: 12/05/2022] Open
Abstract
Background We conducted a systematic review to evaluate the role of Ultrasonic dissector (UAS) versus conventional clamp and tie in thyroidectomy. Materials and methods We searched for all published RCT in into electronic databases. To be included in the analysis, the studies had to compare thyroidectomy with UAS versus conventional vessel ligation and tight (conventional technique = CT). The following outcomes were used to compare the total thyroidectomy group with UAS versus CT group: operative duration, operative blood loss, overall drainage volume during the first 24 hours, transiet laryngeal nerve palsy, permanent laryngeal nerve palsy, transiet hypocalcaemia and permanent hypocalcaemia. Results There are currently 7 RCT on this issue to compare thyroidectomy with UAS versus CT. From the analysis of these studies it was possible to confront 608 cases: 303 undergoing to thyroidectomy with UAS versus 305 that were treated with CT. Actually, it was shown a relevant advantage of cost-effectiveness in patients treated with UAS; there is a statistically significant reduction of the operative duration (weighted mean difference [WMD], -18.74 minutes; 95% confidence interval [CI], (-26.97 to -10.52 minutes) (P = 0.00001), intraoperative blood loss (WMD, -60.10 mL; 95% CI, -117.04 to 3.16 mL) (P = 0.04) and overall drainage volume (WMD, -35.30 mL; 95% CI, -49.24 to 21.36 mL) (P = 0.00001) in the patients underwent thyroidectomy with UAS. Although the analysis showed that the patients who were treated with USA presented more favourable results in incidence of post-operative complications (transient laryngeal nerve palsy: P = 0.11; permanent laryngeal nerve palsy: not estimable; transient hypocalcaemia: P = 0.24; permanent hypocalcaemia: P = 0.45), these data didn't present statistical relevance. Conclusion This meta-analysis shown a relevant advantage only in terms of cost-effectiveness in patients treated with UAS; it is subsequent to statistically significant reduction of operation duration, intraoperative blood loss and of overall drainage volume during the first 24 hours. Although the analysis showed that the patients who were treated with UAS presented more favourable results in incidence of post-operative complications (transiet laryngeal nerve palsy; transiet hypocalcaemia and permanent hypocalcaemia), these data didn't present statistical relevance.
Collapse
Affiliation(s)
- Roberto Cirocchi
- General and Emergency Surgical Unit, Department of Surgical Sciences, Radiology and Dentistry, University of Perugia, Perugia, Italy.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Ligasure vessel-sealing system or harmonic scalpel versus conventional vessel ligation for thyroidectomy. Hippokratia 2010. [DOI: 10.1002/14651858.cd008778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
46
|
López-Anglada Fernández E, Braña Vigil A. Experiencia en la utilización de bisturí de ultrasonidos en cirugía ortopédica. Rev Esp Cir Ortop Traumatol (Engl Ed) 2010. [DOI: 10.1016/j.recot.2010.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
47
|
Ecker T, Carvalho AL, Choe JH, Walosek G, Preuss KJ. Hemostasis in thyroid surgery: Harmonic scalpel versus other techniques—a meta-analysis. Otolaryngol Head Neck Surg 2010; 143:17-25. [PMID: 20620614 DOI: 10.1016/j.otohns.2010.03.018] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2009] [Revised: 03/05/2010] [Accepted: 03/16/2010] [Indexed: 11/15/2022]
Abstract
Objective: The objective is to systematically review the literature studying the harmonic scalpel versus other hemostatic techniques in thyroid surgical patients. Although thyroidectomy is one of the most common surgical procedures, the safest, most efficient, and cost-effective way to achieve hemostasis is hotly debated. Data Sources: We searched the electronic databases Medline and the Cochrane Library using relevant search strategies. Review Methods: Two reviewers (G.W., T.E.) independently assessed titles and abstracts of 72 identified studies. Twelve prospective randomized controlled studies were considered relevant and included in this meta-analysis (1153 patients). Results: In all studies, operating time was reduced by using the harmonic scalpel. Compared with surgical hemostasis by suture ligation or suture/clip ligation combined with electrocauterization or electrothermal bipolar vessel sealer (n = 602), the mean operating time reduction for the harmonic scalpel was equivalent to 22.67 minutes (95% CI, −27.98; −17.37, P < 0.00001) or nearly 25 percent of the total operating room time. When harmonic scalpel was used, blood loss was reduced significantly by 20.03 mL (95% CI, −27.83; −12.22, P < 0.00001), and a mean reduction in postoperative pain (0.86 points [95% CI, −1.60; −0.13, P = 0.02]) was measured. Length of stay was reduced by 0.12 days (95% CI, −0.25; 0.00, P = 0.05). Differences regarding volume of drainage fluid were in favor of harmonic scalpel but not statistically significant; complications were similar in both groups. Conclusion: There is clear evidence that using the harmonic scalpel for hemostasis in thyroid surgery significantly reduces operating time and blood loss and that it is not associated with an increase in volume of drainage fluid, complication rate, or hospital stay.
Collapse
Affiliation(s)
| | | | - Jun-Ho Choe
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | | | | |
Collapse
|
48
|
Zhang ZJ, Peng Zhang, Tian JH, Jun Li, Lun Li, Jing Tian, Yang KH. Ultrasonic Coagulator for Thyroidectomy: A Systematic Review of Randomized Controlled Trials. Surg Innov 2010; 17:41-7. [DOI: 10.1177/1553350610362084] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objective: To evaluate the effect of ultrasonic coagulator for thyroidectomy. Methods: randomized controlled trials were searched in PubMed, EMBASE, Cochrane Library, SCI, Chinese Biomedical Database, China Academic Journals Full-Text Database, Chinese Scientific Journals Database, and China Online Journals. The authors evaluated the quality of included studies by Handbook 5.0.0, and analyzed data by Cochrane Collaboration’s RevMan 5.0. Results: A total of 11 RCTs with 1420 patients met the criteria. Between ultrasonic coagulator and conventional technique, there were significant differences in operative time of total thyroidectomy ( P < .00001) and amount of intraoperative bleeding ( P = .02). There were no significant differences in operative time of part thyroidectomy ( P = .07), amount of postoperative drainage ( P = .18), cases of transient hypocalcemia ( P = .41), cases of transient recurrent nerve paresis ( P = .21), and total cost in hospital ( P = .08). Conclusions: Current studies demonstrate that ultrasonic coagulator has a significant reduction on the operating time of total thyroidectomy and the amount of intraoperative bleeding in thyroidectomy, without increasing complications and total cost in hospital.
Collapse
Affiliation(s)
- Zong-jiu Zhang
- Lanzhou University, Lanzhou, China, Ministry of Public Health, Beijing, China
| | | | | | - Jun Li
- Lanzhou University, Lanzhou, China, Ministry of Public Health, Beijing, China
| | - Lun Li
- Lanzhou University, Lanzhou, China
| | | | | |
Collapse
|
49
|
Harmonic scalpel compared to conventional hemostasis in thyroid surgery: a meta-analysis of randomized clinical trials. Int J Surg Oncol 2010; 2010:396079. [PMID: 22482046 PMCID: PMC3265258 DOI: 10.1155/2010/396079] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2009] [Revised: 11/09/2009] [Accepted: 12/06/2009] [Indexed: 01/19/2023] Open
Abstract
Background. The study's aim was to determine whether conventional hemostasis (CH) or the Harmonic Scalpel (HS) results in shorter operative times for thyroidectomy and to evaluate the incidence of postoperative complications with each approach. Methods. A literature search was conducted from study inception to September 30, 2008. Included studies randomized thyroidectomy patients to either CH or HS and reported the incidence of postoperative transient recurrent laryngeal nerve dysfunction (RLND) and hypocalcemia. Results. Nine RCTs were included. Use of the HS reduced operative time by 23.1 minutes (95% CI = 13.8, 32.33). There was no difference in the incidence of transient RLND (RR = 1.25, 95% CI = .56, 2.76), but a lower rate of transient hypocalcemia with the use of the HS (RR = .69, 95% CI = .51, .92). Conclusions. The use of HS in thyroidectomy significantly reduces operative time and is associated with a reduction in postoperative hypocalcemia compared to CH.
Collapse
|
50
|
Experience in the Use of Ultrasonic Scalpels in Orthopaedic Surgery. Rev Esp Cir Ortop Traumatol (Engl Ed) 2010. [DOI: 10.1016/s1988-8856(10)70251-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|