1
|
Mulvaney G, Sowah MN, DeCarlo R, Drossopoulos P, Holland CM, Bohl MA. Biomechanical Analysis of Pedicle Screw Reinsertion Along the Same Trajectory in a Validated 3D-Printed Synthetic Bone Model. World Neurosurg 2024:S1878-8750(24)01342-1. [PMID: 39103047 DOI: 10.1016/j.wneu.2024.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Revised: 07/31/2024] [Accepted: 08/01/2024] [Indexed: 08/07/2024]
Abstract
OBJECTIVE To investigate the biomechanical properties of pedicle screw reinsertion along the same trajectory in a previously validated synthetic bone model. METHODS Twenty identical acrylonitrile butadiene styrene models of lumbar vertebrae were three-dimensional-printed. Screws were placed in the standard fashion into each pedicle. Models were separated into 2 equal groups, control and experimental. Experimental group screws were completely removed from their testing block and reinserted once. All screws in both groups were then forcibly removed. Continuous torque monitoring was collected on screw insertion torque (IT), removal torque, and reinsertion torque. Pullout strength (PO), screw stiffness (STI), and strain energy (STR) were calculated. RESULTS There was no significant difference between control and experimental groups for PO (P = 0.26), STI (P = 0.55), STR (P = 0.50), or IT (P = 0.24). There was a significant decrease in reinsertion torque (54.5 N-cm ± 8.2 N-cm) from control IT (62.9 N-cm ± 8.4 N-cm, P = 0.045) and experimental IT (67.5 N-cm ± 7.6 N-cm, P = 0.0026). Strong correlations (Pearson's r > 0.80) were seen between control IT against STR and PO, between each of the experimental torque measurements, and between experimental PO and STI. CONCLUSIONS Despite a significant decrease in insertion torque, there is no significant loss of pedicle screw performance when a screw is removed and reinserted along the same trajectory.
Collapse
Affiliation(s)
- Graham Mulvaney
- Department of Neurosurgery, Atrium Health Carolinas Medical Center, Charlotte, North Carolina, USA.
| | - Mareshah N Sowah
- University of South Carolina School of Medicine Greenville, Greenville, South Carolina, USA
| | - Rebecca DeCarlo
- Department of Neurosurgery, Atrium Health Carolinas Medical Center, Charlotte, North Carolina, USA
| | - Peter Drossopoulos
- University of North Carolina School of Medicine, Chapel Hill, North Carolina, USA
| | | | - Michael A Bohl
- Carolina Neurosurgery and Spine Associates, Charlotte, North Carolina, USA
| |
Collapse
|
2
|
Bennie S, Crowley JD, Wang T, Pelletier MH, Walsh WR. Pedicle screw pull-out testing in polyurethane foam blocks: Effect of block orientation and density. Proc Inst Mech Eng H 2024; 238:455-460. [PMID: 38480483 DOI: 10.1177/09544119241236873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2024]
Abstract
Synthetic bone models such as polyurethane (PU) foam are a well-established substitute to cadaveric bone for screw pull-out testing; however, little attention has been given to the effect of PU foam anisotropy on orthopaedic implant testing. Compressive and screw pull-out performance in three PU foam densities; 0.16 g/cm3 (PCF 10), 0.32 g/cm3 (PCF 20) and 0.64 g/cm3 (PCF 40) were performed in each of the X, Y or Z orientations. The maximum compressive force, stiffness in the linear region, maximum stress and modulus were determined for all compression tests. Pedicle screws were inserted and pulled out axially to determine maximum pull-out force, energy to failure and stiffness. One-way ANOVA and post hoc tests were used to compare outcome variables between PU foam densities and orientations, respectively. Compression tests demonstrated the maximum force was significantly different between all orientations for PCF 20 (X, Y and Z) while stiffness and maximum stress were different between X versus Y and X versus Z. Maximum pull-out force was significantly different between all orientations for PCF 10 foam. No significant differences were noted for other foam densities. There is potential for screw pull-out testing results to be significantly affected by orientation in lower density PU foams. It is recommended that a single, known orientation of the PU foam block be used for experimental testing.
Collapse
Affiliation(s)
- Stephen Bennie
- Surgical & Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, UNSW Sydney, Sydney, NSW, Australia
| | - James Douglas Crowley
- Surgical & Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, UNSW Sydney, Sydney, NSW, Australia
| | - Tian Wang
- Surgical & Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, UNSW Sydney, Sydney, NSW, Australia
| | - Matthew Henry Pelletier
- Surgical & Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, UNSW Sydney, Sydney, NSW, Australia
| | - William Robert Walsh
- Surgical & Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, UNSW Sydney, Sydney, NSW, Australia
| |
Collapse
|
3
|
Li YD, Lai PL, Hsieh MK, Chen WP, Lee DM, Tsai TT, Tai CL. Influence of various pilot hole profiles on pedicle screw fixation strength in minimally invasive and traditional spinal surgery: a comparative biomechanical study. Front Bioeng Biotechnol 2024; 12:1359883. [PMID: 38380264 PMCID: PMC10877418 DOI: 10.3389/fbioe.2024.1359883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 01/25/2024] [Indexed: 02/22/2024] Open
Abstract
Despite advancements in pedicle screw design and surgical techniques, the standard steps for inserting pedicle screws still need to follow a set of fixed procedures. The first step, known as establishing a pilot hole, also referred to as a pre-drilled hole, is crucial for ensuring screw insertion accuracy. In different surgical approaches, such as minimally invasive or traditional surgery, the method of creating pilot holes varies, resulting in different pilot hole profiles, including variations in size and shape. The aim of this study is to evaluate the biomechanical properties of different pilot hole profiles corresponding to various surgical approaches. Commercially available synthetic L4 vertebrae with a density of 0.16 g/cc were utilized as substitutes for human bone. Four different pilot hole profiles were created using a 3.0 mm cylindrical bone biopsy needle, 3.6 mm cylindrical drill, 3.2-5.0 mm conical drill, and 3.2-5.0 mm conical curette for simulating various minimally invasive and traditional spinal surgeries. Two frequently employed screw shapes, namely, cylindrical and conical, were selected. Following specimen preparation, screw pullout tests were performed using a material test machine, and statistical analysis was applied to compare the mean maximal pullout strength of each configuration. Conical and cylindrical screws in these four pilot hole configurations showed similar trends, with the mean maximal pullout strength ranking from high to low as follows: 3.0 mm cylindrical biopsy needle, 3.6 mm cylindrical drill bit, 3.2-5.0 mm conical curette, and 3.2-5.0 mm conical drill bit. Conical screws generally exhibited a greater mean maximal pullout strength than cylindrical screws in three of the four different pilot hole configurations. In the groups with conical pilot holes, created with a 3.2-5.0 mm drill bit and 3.2-5.0 mm curette, both conical screws exhibited a greater mean maximal pullout strength than did cylindrical screws. The strength of this study lies in its comprehensive comparison of the impact of various pilot hole profiles commonly used in clinical procedures on screw fixation stability, a topic rarely reported in the literature. Our results demonstrated that pilot holes created for minimally invasive surgery using image-guided techniques exhibit superior pullout strength compared to those utilized in traditional surgery. Therefore, we recommend prioritizing minimally invasive surgery when screw implantation is anticipated to be difficult or there is a specific need for stronger screw fixation. When opting for traditional surgery, image-guided methods may help establish smaller pilot holes and increase screw fixation strength.
Collapse
Affiliation(s)
- Yun-Da Li
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
- Department of Orthopedic Surgery, New Taipei Municipal TuCheng Hospital (Built and Operated by Chang Gung Medical Foundation), New Taipei City, Taiwan
| | - Po-Liang Lai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Ming-Kai Hsieh
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Weng-Pin Chen
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan
| | - De-Mei Lee
- Department of Mechanical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Tsung-Ting Tsai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Ching-Lung Tai
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| |
Collapse
|
4
|
Li YD, Hsieh MK, Chen WP, Lee DM, Tsai TT, Lai PL, Tai CL. Biomechanical evaluation of pedicle screw stability after 360-degree turnback from full insertion: effects of screw shape, pilot hole profile and bone density. Front Bioeng Biotechnol 2023; 11:1151627. [PMID: 37214307 PMCID: PMC10196264 DOI: 10.3389/fbioe.2023.1151627] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 04/26/2023] [Indexed: 05/24/2023] Open
Abstract
Intraoperative pedicle screw depth adjustment after initial insertion, including both forward and backward adjustments, is sometimes necessary to facilitate rod application and ensure that the screw is in the correct position, which is determined by intraoperative fluoroscopy. Adjusting the screw with forward turns has no negative influence on the screw fixation stability; however, screw turnback may weaken the fixation stability. The aim of this study is to evaluate the biomechanical properties of screw turnback and demonstrate the reduction in the fixation stability after the screw is turned 360° from its full insertion position. Commercially available synthetic closed-cell polyurethane foams with three different densities simulating various degrees of bone density were utilized as substitutes for human bone. Two different screw shapes (cylindrical and conical) together with two different pilot hole profiles (cylindrical and conical) were tested. Following specimen preparation, screw pullout tests were conducted using a material test machine. The mean maximal pullout strength between full insertion and 360-degree turnback from full insertion in each setting was statistically analyzed. The mean maximal pullout strength after 360-degree turnback from full insertion was generally lower than that at full insertion. The reduced mean maximal pullout strength after turnback increased with decreasing bone density. Conical screws had significantly lower pullout strength after 360-degree turnback than cylindrical screws. The mean maximal pullout strength was reduced by up to approximately 27% after 360-degree turnback when using a conical screw in a low bone density specimen. Additionally, specimens treated with a conical pilot hole presented a less reduction in pullout strength after screw turnback as compared to those with a cylindrical pilot hole. The strength of our study was that we systematically investigated the effects of various bone densities and screw shapes on screw stability after turnback, which has rarely been reported in the literature. Our study suggests that pedicle screw turnback after full insertion should be reduced in spinal surgeries, particularly procedures that use conical screws in osteoporotic bone. Pedicle screw secured with a conical pilot hole might be beneficial for screw adjustment.
Collapse
Affiliation(s)
- Yun-Da Li
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
- Department of Orthopaedic Surgery, New Taipei Municipal TuCheng Hospital, Built and Operated by Chang Gung Medical Foundation, New TaipeiCity, Taiwan
| | - Ming-Kai Hsieh
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Weng-Pin Chen
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan
| | - De-Mei Lee
- Department of Mechanical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Tsung-Ting Tsai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Po-Liang Lai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Ching-Lung Tai
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| |
Collapse
|
5
|
Experimental Evaluation of Screw Pullout Force and Adjacent Bone Damage According to Pedicle Screw Design Parameters in Normal and Osteoporotic Bones. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9030586] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
This paper proposes an optimum design of the pedicle screw with respect to bone density and variables of the screw design. First, pedicle screws are designed and manufactured with design variables including the core diameter and conical angle that affect the pullout force of the pedicle screw. Variables of bone density are also classified into two groups, namely grade 10 (0.16 g/cc) with osteoporotic bone density and grade 20 (0.32 g/cc) with normal bone density. The effect of each parameter on the pullout force and relationship between the pullout force and screw designs are investigated. Furthermore, bone damage after fixation failure or insertion in the patient body is considered separately from the pullout strength. Therefore, cross sectional images of the artificial bone are observed to analyze the degree of damage after the pullout test of the pedicle screw by using micro-CT (computed tomography). The region and degree of bone damage are quantitatively analyzed. The effects of the core diameter and conical angle of the pedicle screw on the pulling force, bone damage, and fracture behavior are analyzed via the aforementioned experiments and analysis. An optimal pedicle screw design is suggested based on the experimental results.
Collapse
|
6
|
The Effects of Geometrical Parameters of the Pedicle Screw on Its Pullout Strength: In-Vitro Animal Tests. JOURNAL OF ORTHOPEDIC AND SPINE TRAUMA 2017. [DOI: 10.5812/jost.74189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
7
|
Pelletier MH, Bertollo N, Al-Khawaja D, Walsh WR. The contribution of the cortical shell to pedicle screw fixation. JOURNAL OF SPINE SURGERY 2017; 3:184-192. [PMID: 28744499 DOI: 10.21037/jss.2017.06.07] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND A pedicle screw insertion technique known as "hubbing" involves the removal of cortical bone around the screw insertion with the aim of improving fixation and decreasing screw loosening. However, the efficacy of this procedure relative to bone density and early loading have not been fully explored. The purpose of this study is to establish the contribution of the cortical layer (hubbing), cancellous density, early loading (toggling) in an idealised model. This is an in vitro laboratory study. METHODS Synthetic bone blocks with cancellous bulk and a simulated cortical shell were implanted with 6.5 mm pedicle screws. Three key variables were evaluated in this study; density of the simulated bone (10-20 lb/ft3), toggling (±0.5 mm for 10,000 cycles), and the presence or absence of the surrounding cortex (hubbing). Pullout testing after toggling was performed to determine maximum load, stiffness and energy. Results were analyzed to assess interaction and main effects. RESULTS Removal of the cortex decreased the pullout loads by approximately 1,100 N after toggling. Toggling in the presence of the cortical shell had no effect. However, once the cortical shell is removed damage to the weaker cancellous bone accumulates and further compromises the fixation. CONCLUSIONS The addition of a cortical layer in the Sawbone model is significant and provides a more realistic model of load sharing. The cortex plays a considerable role in the protection of underlying cancellous bone as well as contributing to initial pullout strength. The results of this study demonstrate a negative synergistic effect when both toggling and hubbing are applied to the weaker bone.
Collapse
Affiliation(s)
- Matthew Henry Pelletier
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School, UNSW Australia, Prince of Wales Hospital, Sydney, NSW 2031, Australia
| | - Nicky Bertollo
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School, UNSW Australia, Prince of Wales Hospital, Sydney, NSW 2031, Australia
| | - Darweesh Al-Khawaja
- Department of Neurosurgery, Wollongong Hospital, Wollongong, New South Wales 2500, Australia
| | - William Robert Walsh
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School, UNSW Australia, Prince of Wales Hospital, Sydney, NSW 2031, Australia
| |
Collapse
|
8
|
The Effect of Transpedicular Screw Design on Its Performance in Vertebral Bone Under Tensile Loads: A Parametric Study. Clin Spine Surg 2016; 29:433-440. [PMID: 27879505 DOI: 10.1097/bsd.0b013e3182a03c70] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
STUDY DESIGN A biomechanical study using bovine thoracolumbar spines. OBJECTIVE To study investigated whether thread design parameters aimed at altering the state of stress at the screw-bone interface increase the screw's holding power. SUMMARY AND BACKGROUND DATA Internal spinal fixators utilizing transpedicular screw fixation are used to achieve early stabilization of the injured spine in a range of clinical conditions. Despite advances in the design of internal spinal fixation systems, implant loosening, and catastrophic failures at the screw-bone interface remains a serious complication in adult spine surgery. Although the performance of the screws in the vertebral bone critically depends on ability of screw thread design to provide and maintain adequate bone purchase, the effect of individual thread design parameters on screw performance and the failure process of the screw-bone interface, remains unclear. METHODS On the basis of the AO Schanz thread, this parametric study used 96 lumbar bovine vertebrae instrumented with 19 screw designs to investigate the effects of pitch, ratio of major to minor diameter, screw insertion depth, and major diameter, on screw performance under pure tensile loading. The effect of vertebral morphometry on screw performance and the extent of damage within the failed screw-bone interface were evaluated. RESULTS The increase in screw insertion depth, screw pitch, and the ratio of major to minor diameter, significantly affected screw performance under tensile loads. Complex interactions existed between the major diameter and each of the design variables. Vertebral morphometry had little effect on screw performance while the damage within the failed bone-screw interface confined to the immediate region of the screw threads. CONCLUSIONS Design variables, able to reduce shear stresses or modify the complex stress profile at the bone-screw interface, are more effective in preventing early failure of the interface.
Collapse
|
9
|
Demir T. A new alternative to expandable pedicle screws: Expandable poly-ether-ether-ketone shell. Proc Inst Mech Eng H 2015; 229:386-94. [PMID: 25991716 DOI: 10.1177/0954411915584430] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Screw pullout is a very common problem in the fixation of sacrum with pedicle screws. The principal cause of this problem is that the cyclic micro motions in the fixation of sacrum are higher than the other regions of the vertebrae that limit the osteo-integration between bone and screw. In addition to that, the bone quality is very poor at sacrum region. This study investigated a possible solution to the pullout problem without the expandable screws' handicaps. Newly designed poly-ether-ether-ketone expandable shell and classical pedicle screws were biomechanically compared. Torsion test, pullout tests, fatigue tests, flexion/extension moment test, axial gripping capacity tests and torsional gripping capacity tests were conducted in accordance with ASTM F543, F1798 and F1717. Standard polyurethane foam and calf vertebrae were used as embedding medium for pullout tests. Classical pedicle screw pullout load on polyurethane foam was 564.8 N compared to the failure load for calf vertebrae's 1264 N. Under the same test conditions, expandable poly-ether-ether-ketone shell system's pullout loads from polyurethane foam and calf vertebrae were 1196.3 and 1890 N, respectively. The pullout values for expandable poly-ether-ether-ketone shell were 33% and 53% higher than classical pedicle screw on polyurethane foam and calf vertebrae, respectively. The expandable poly-ether-ether-ketone shell exhibited endurance on its 90% of yield load. Contrary to poly-ether-ether-ketone shell, classical pedicle screw exhibited endurance on 70% of its yield load. Expandable poly-ether-ether-ketone shell exhibited much higher pullout performance than classical pedicle screw. Fatigue performance of expandable poly-ether-ether-ketone shell is also higher than classical pedicle screw due to damping the micro motion capacity of the poly-ether-ether-ketone. Expandable poly-ether-ether-ketone shell is a safe alternative to all other expandable pedicle screw systems on mechanical perspective.
Collapse
Affiliation(s)
- Teyfik Demir
- Department of Mechanical Engineering, TOBB University of Economics and Technology, Ankara, Turkey
| |
Collapse
|
10
|
Kang DG, Lehman RA, Wagner SC, Bevevino AJ, Tracey RW, Gaume RE, Dmitriev AE. Effects of rod reduction on pedicle screw fixation strength in the setting of Ponte osteotomies. Spine J 2015; 15:146-52. [PMID: 25088957 DOI: 10.1016/j.spinee.2014.07.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2014] [Revised: 06/10/2014] [Accepted: 07/29/2014] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT The use of a rod reduction device can have deleterious consequences on pedicle screw pullout strength (POS) in the thoracic spine. However, posterior-only osteotomies in the thoracic spine are often performed to improve flexibility of the spine and offset forces of deformity correction maneuvers. PURPOSE To investigate the effect on pedicle screw POS caused by the rod reduction technique in the presence of facet osteotomies in the thoracic spine. STUDY DESIGN/SETTING The study is a biomechanical study using human cadaveric spine specimens. METHODS Thoracic Ponte osteotomies were performed on 3 thoracic levels in 15 cadaveric specimens. The right rod was contoured with a 5-mm residual gap at the middle level and was reduced using a rod reduction device. On the left side (paired control), a rod with no mismatch was placed. Biomechanical testing was performed with tensile load to failure "in line" with the screw axis and POS measured in Newtons (N). RESULTS After rod reduction, thoracic pedicle screw POS was significantly decreased (40%) compared with the control (419±426 N vs. 708±462 N, p=.002) and remained statistically significant after adjusting for bone mineral density (BMD) (p=.05). Eleven (73%) of the pedicle screws had visible pullout/failure during the reduction attempt and occurred irrespective of BMD. CONCLUSIONS Despite thoracic Ponte osteotomies and increased flexibility of the spinal segments, the rod reduction device still significantly decreased pedicle screw POS, typically resulting in outright failure of the screw-bone interface. Therefore, rod reduction technique of any kind should be performed with caution as it frequently results in suboptimal pedicle screw fixation.
Collapse
Affiliation(s)
- Daniel G Kang
- Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bldg 19, Rm #2101, Bethesda, MD 20889, USA
| | - Ronald A Lehman
- Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bldg 19, Rm #2101, Bethesda, MD 20889, USA; Division of Orthopaedics, Department of Surgery, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814, USA.
| | - Scott C Wagner
- Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bldg 19, Rm #2101, Bethesda, MD 20889, USA
| | - Adam J Bevevino
- Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bldg 19, Rm #2101, Bethesda, MD 20889, USA
| | - Robert W Tracey
- Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bldg 19, Rm #2101, Bethesda, MD 20889, USA
| | - Rachel E Gaume
- Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bldg 19, Rm #2101, Bethesda, MD 20889, USA
| | - Anton E Dmitriev
- Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bldg 19, Rm #2101, Bethesda, MD 20889, USA; Division of Orthopaedics, Department of Surgery, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814, USA
| |
Collapse
|
11
|
Pedicle screw reinsertion using previous pilot hole and trajectory does not reduce fixation strength. Spine (Phila Pa 1976) 2014; 39:1640-7. [PMID: 24979143 DOI: 10.1097/brs.0000000000000477] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Fresh-frozen human cadaveric biomechanical study. OBJECTIVE To evaluate the biomechanical consequence of pedicle screw reinsertion in the thoracic spine. SUMMARY OF BACKGROUND DATA During pedicle screw instrumentation, abnormal appearance on fluoroscopic imaging or low current reading with intraoperatively evoked electromyographic stimulation of a pedicle screw warrants complete removal to reassess for pedicle wall violation or screw malposition. However, screw fixation strength has never been evaluated biomechanically after reinsertion using a previous pilot hole and trajectory. METHODS Thirty-one thoracic individual fresh-frozen human cadaveric vertebral levels were instrumented bilaterally with 5.5-mm titanium polyaxial pedicle screws, and insertional torque (IT) was measured with each revolution. A paired comparison was performed for each level. Screw reinsertion was performed by completely removing the pedicle screw, palpating the tract, and then reinserting along the same trajectory. Screws were tensile loaded to failure "in-line" with the screw axis. RESULTS There was no significant difference for pedicle screw pullout strength (POS) between reinserted and control screws (732 ± 307 N vs. 742 ± 320 N, respectively; P = 0.78). There was no significant difference in IT between initial insertion for the test group (INI) (0.82 ± 0.40 N·m) and control (0.87 ± 0.50 N·m) (P = 0.33). IT for reinserted screws (0.58 ± 0.47 N·m) had significantly decreased compared with INI and control screws (29% decrease, P = 0.00; 33% decrease, P = 0.00, respectively). The test group screws in the thoracic spine had significant correlations between initial IT and POS (r = 0.79, P = 0.00), and moderate correlations between reinsertion IT and POS in the thoracic spine (r = 0.56, P = 0.00). CONCLUSION Despite a significant reduction in pedicle screw IT, there was no significant difference in pedicle screw POS with reinsertion. Therefore, when surgeons must completely remove a pedicle screw for tract inspection, reinsertion along the same trajectory may be performed without significantly compromising fixation strength. LEVEL OF EVIDENCE N/A.
Collapse
|
12
|
Biomechanical evaluation of bending strength of spinal pedicle screws, including cylindrical, conical, dual core and double dual core designs using numerical simulations and mechanical tests. Med Eng Phys 2014; 36:1218-23. [DOI: 10.1016/j.medengphy.2014.06.014] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Revised: 06/10/2014] [Accepted: 06/28/2014] [Indexed: 11/19/2022]
|
13
|
Amaritsakul Y, Chao CK, Lin J. Comparison study of the pullout strength of conventional spinal pedicle screws and a novel design in full and backed-out insertions using mechanical tests. Proc Inst Mech Eng H 2014; 228:250-7. [DOI: 10.1177/0954411914522437] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Recently, new pedicle screw designs have been developed. However, these designs’ performances are still unclear, especially when backed out after insertion. The objective of this study was to investigate the performances of different screw designs when backed out from full insertion. Seven conventional designs of the pedicle screw and one novel design were inserted into polyurethane foam (0.32 g/cm3). All screws were first fully inserted (43 mm) and were backed out 360°. Axial pullout tests were performed and the reaction force was measured. The results showed that the conical screw of type 1 with a small inner diameter provided the highest pullout strength in both full insertion and backed-out insertion (2401.85 and 2169.82 N, respectively). However, this screw’s pullout strength significantly decreased (9.7%) when backed out from full insertion. There was no significant difference between the conical screw of type 1 with a small inner diameter and double duo core screw ( p > 0.01) in backed-out insertion. The cylindrical screw with a small diameter, dual inner core screw and double dual core screw also provided good results in both full insertion (2115.44, 2182.99 and 2226.93 N, respectively) and backed-out conditions (2065.80, 2014.28 and 1941.29 N, respectively). The increased pullout strength of the conical design could be due to the effect of bone compaction. However, the screw exhibited less consistent pullout strength when backed out when compared with the other designs. The conical screw should be inserted to the precise position without turning back, especially in osteoporosis patients. The dual inner core screw and double dual core screw could provide greater stability in both conditions. Care should be taken when using both the cylindrical screw with a small thread depth and the dual outer core screw.
Collapse
Affiliation(s)
- Yongyut Amaritsakul
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan, ROC
| | - Ching-Kong Chao
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan, ROC
| | - Jinn Lin
- Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei, Taiwan, ROC
| |
Collapse
|
14
|
Paik H, Kang DG, Lehman RA, Gaume RE, Ambati DV, Dmitriev AE. The biomechanical consequences of rod reduction on pedicle screws: should it be avoided? Spine J 2013; 13:1617-26. [PMID: 23769931 DOI: 10.1016/j.spinee.2013.05.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2011] [Revised: 05/27/2012] [Accepted: 05/04/2013] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. PURPOSE To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. METHODS Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. RESULTS Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p<.05) and significantly decreased work energy to failure (p<.05). Nearly half (n=7) of the pedicle screws had failed during the reduction attempt with visible pullout of the screw. After reduction, decreased POS was observed in both normal (p<.05) and osteoporotic (p<.05) bone. Back out and reinsertion of the screw resulted in no significant difference in mean POS, stiffness, and work energy to failure (p>.05). CONCLUSIONS In circumstances where a rod is not fully seated within the pedicle screw, the use of a rod persuasion device decreases the overall POS and work energy to failure of the screw or results in outright failure. Further rod contouring or correction of pedicle screw depth of insertion may be warranted to allow for appropriate alignment of the longitudinal rods.
Collapse
Affiliation(s)
- Haines Paik
- Department of Orthopaedic Surgery and Rehabilitation, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bethesda, MD 20889, USA
| | | | | | | | | | | |
Collapse
|
15
|
Brasiliense LBC, Lazaro BCR, Reyes PM, Newcomb AGUS, Turner JL, Crandall DG, Crawford NR. Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines. Spine J 2013; 13:947-56. [PMID: 23602373 DOI: 10.1016/j.spinee.2013.03.010] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2011] [Revised: 10/13/2012] [Accepted: 03/07/2013] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Novel dual-threaded screws are configured with overlapping (doubled) threads only in the proximal shaft to improve proximal cortical fixation. PURPOSE Tests were run to determine whether dual-threaded pedicle screws improve pullout resistance and increase fatigue endurance compared with standard pedicle screws. STUDY DESIGN/SETTING In vitro strength and fatigue tests were performed in human cadaveric vertebrae and in polyurethane foam test blocks. PATIENT SAMPLE Seventeen cadaveric lumbar vertebrae (14 pedicles) and 40 test sites in foam blocks were tested. OUTCOME MEASURES Measures for comparison between standard and dual-threaded screws were bone mineral density (BMD), screw insertion torque, ultimate pullout force, peak load at cyclic failure, and pedicular side of first cyclic failure. METHODS For each vertebral sample, dual-threaded screws were inserted in one pedicle and single-threaded screws were inserted in the opposite pedicle while recording insertion torque. In seven vertebrae, axial pullout tests were performed. In 10 vertebrae, orthogonal loads were cycled at increasing peak values until toggle exceeded threshold for failure. Insertion torque and pullout force were also recorded for screws placed in foam blocks representing healthy or osteoporotic bone porosity. RESULTS In bone, screw insertion torque was 183% greater with dual-threaded than with standard screws (p<.001). Standard screws pulled out at 93% of the force required to pull out dual-threaded screws (p=.42). Of 10 screws, five reached toggle failure first on the standard screw side, two screws failed first on the dual-threaded side, and three screws failed on both sides during the same round of cycling. In the high-porosity foam, screw insertion torque was 60% greater with the dual-threaded screw than with the standard screw (p=.005), but 14% less with the low-porosity foam (p=.07). Pullout force was 19% less with the dual-threaded screw than with the standard screw in the high-porosity foam (p=.115), but 6% greater with the dual-threaded screw in the low-porosity foam (p=.156). CONCLUSIONS Although dual-threaded screws required higher insertion torque than standard screws in bone and low density foam, dual-threaded and standard pedicle screws exhibited equivalent axial pullout and cyclic fatigue endurance. Unlike single-threaded screws, the mechanical performance of dual-threaded screws in bone was relatively independent of BMD. In foam, the mechanical performance of both types of screws was highly dependent on porosity.
Collapse
Affiliation(s)
- Leonardo B C Brasiliense
- Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, 350 W. Thomas Rd, Phoenix, AZ 85013, USA
| | | | | | | | | | | | | |
Collapse
|
16
|
Helgeson MD, Kang DG, Lehman RA, Dmitriev AE, Luhmann SJ. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection. Spine J 2013; 13:957-65. [PMID: 23602374 DOI: 10.1016/j.spinee.2013.03.012] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Revised: 02/16/2013] [Accepted: 03/07/2013] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. PURPOSE The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. STUDY DESIGN In vitro human cadaveric biomechanical analysis. METHODS Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each specimen. Each pedicle was incrementally tapped to increasing size (3.75, 4.00, 4.50, and 5.50 mm) until the threshold value was reached based on the assigned group. Pedicle screw size was determined by adding 1 mm to the tap size that crossed the threshold torque value. Torque measurements were recorded with each revolution during tap and pedicle screw insertion. Each specimen was then individually potted and pedicle screws pulled out "in-line" with the screw axis at a rate of 0.25 mm/sec. Peak pullout strength (POS) was measured in Newtons (N). RESULTS The peak tapping IT was significantly increased (50%) in Group 2 (3.23 ± 0.65 in-lbs) compared with Group 1 (2.15 ± 0.56 in-lbs) (p=.0005). The peak screw IT was also significantly increased (19%) in Group 2 (8.99 ± 2.27 in-lbs) compared with Group 1 (7.52 ± 2.96 in-lbs) (p=.02). The pedicle screw pullout strength was also significantly increased (23%) in Group 2 (877.9 ± 235.2 N) compared with Group 1 (712.3 ± 223.1 N) (p=.017). The mean pedicle screw diameter was significantly increased in Group 2 (5.70 ± 1.05 mm) compared with Group 1 (5.00 ± 0.80 mm) (p=.0002). There was also an increased rate of optimal pedicle screw size selection in Group 2 with 9 of 15 (60%) pedicle screws compared with Group 1 with 4 of 15 (26.7%) pedicle screws within 1 mm of the measured pedicle width. There was a moderate correlation for tapping IT with both screw IT (r=0.54; p=.002) and pedicle screw POS (r=0.55; p=.002). CONCLUSIONS Our findings suggest that tapping IT directly correlates with pedicle screw IT, pedicle screw pullout strength, and optimal pedicle screw size. Therefore, tapping IT may be used during thoracic pedicle screw instrumentation as an adjunct to preoperative imaging and clinical experience to maximize fixation strength and optimize pedicle "fit and fill" with the largest screw possible. However, further prospective, in vivo studies are necessary to evaluate the intraoperative use of tapping IT to predict screw loosening/complications.
Collapse
Affiliation(s)
- Melvin D Helgeson
- Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, 8901 Wisconsin Ave., Bethesda, MD 20889, USA
| | | | | | | | | |
Collapse
|
17
|
Silva P, Rosa RC, Shimano AC, Defino HLA. Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2013; 22:1829-36. [PMID: 23653133 DOI: 10.1007/s00586-013-2810-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2012] [Revised: 03/21/2013] [Accepted: 04/28/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE To experimentally study the influence of pilot hole diameter (smaller than or equal to the internal (core) diameter of the screw) on biomechanical (insertion torque and pullout strength) and histomorphometric parameters of screw-bone interface in the acute phase and 8 weeks after pedicle screw insertion. METHODS Fifteen sheep were operated upon and pedicle screws inserted in the L1-L3 pedicles bilaterally. The pilot hole was smaller (2.0 mm) than the internal diameter (core) of the screw on the left side pedicle and equal (2.8 mm) to the internal diameter (core) of the screw on the right side pedicle. Ten animals were sacrificed immediately (five animals were assigned to pullout strength tests and five animals were used for histomorphometric bone-screw interface evaluation). Five animals were sacrificed 8 weeks after pedicle screw insertion for histomorphometric bone-screw interface evaluation. RESULTS The insertion torque and pullout strength were significantly greater in pedicle screws inserted into pilot holes smaller than internal (core) diameter of the screw. Histomorphometric evaluation of bone-screw interface showed that the percentage of bone-implant contact, the area of bone inside the screw thread and the area of bone outside the screw thread were significantly higher for pilot holes smaller than the internal (core) diameter of the screw immediately after insertion and after 8 weeks. CONCLUSION A pilot diameter smaller than the internal (core) diameter of the screw improved the insertion torque and pullout strength immediately after screw insertion as well the pedicle screw-bone interface contact immediately and 8 weeks after screw placement in sheep with good bone mineral density.
Collapse
Affiliation(s)
- Patrícia Silva
- Department of Biomechanic, Medicine and Rehabilitation of the Locomotor System, Faculty of Medicine of Ribeirão Preto, USP, Av. Bandeirantes, 3900, 11°Andar, Ribeirão Preto, São Paulo 14048-900, Brazil.
| | | | | | | |
Collapse
|
18
|
Dodwad SNM, Khan SN. Surgical stabilization of the spine in the osteoporotic patient. Orthop Clin North Am 2013; 44:243-9. [PMID: 23544827 DOI: 10.1016/j.ocl.2013.01.008] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Osteoporosis affects millions of US citizens, and millions more are at risk for developing the disease. Several operative techniques are available to the spine surgeon to provide care for those affected by osteoporosis. The types of osteoporosis, common surgical complications, medical optimization, and surgical techniques in the osteoporotic spine are reviewed, with an emphasis on preoperative planning.
Collapse
Affiliation(s)
- Shah-Nawaz M Dodwad
- Department of Orthopaedics, The Ohio State University, Columbus, OH 43210, USA
| | | |
Collapse
|
19
|
Re: Rajasekaran S, Natarajan RN, Babu JN, et al. Lumbar vertebral growth is governed by “chondral growth force response curve” rather than “Hueter-Volkmann law”: a clinico-biomechanical study of growth modulation changes in childhood spinal tuberculosis. Spine 2011;36:E1435-45. Spine (Phila Pa 1976) 2012; 37:430; author reply 430-1. [PMID: 22366944 DOI: 10.1097/brs.0b013e3182458c8a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
20
|
Kim YY, Choi WS, Rhyu KW. Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study. Spine J 2012; 12:164-8. [PMID: 22336467 DOI: 10.1016/j.spinee.2012.01.014] [Citation(s) in RCA: 91] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2011] [Revised: 10/23/2011] [Accepted: 01/22/2012] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT The pedicle screw fixation system has been used for various spinal disorders. Many studies have been conducted on the fixation ability of the pedicle screw, but variable results have been reported based on bone qualities, pedicle screw properties, insertion techniques, and experimental methods. STUDY DESIGN An experimental and biomechanical study. PURPOSE To evaluate the geometric factors of screws affecting fixation ability after assessing pullout strength based on various pedicle screw designs and different bone densities. METHODS Nine types of pedicle screws were prepared according to the outer diameter shape (cylindrical or conical), the inner diameter shape (cylindrical or conical), and thread shape (V shape, buttress shape, and square shape). The pedicle screws were inserted into standardized polyurethane foams of Grades 5, 15, and 20. The pullout strength of each pedicle screw was determined using an MTS 858 machine (Material Testing System Corp., Minneapolis, MN, USA), and the results were analyzed statistically. RESULTS Pullout strength based on the shape of thread was the highest in the V shape and lowest in the square shape for all foam grades (p<.05). The outer cylindrical and inner conical shape of pedicle screw showed the highest pullout strength in Grades 5 and 15 foam (p<.05). An outer cylindrical and inner conical shape with a V-shaped thread showed the highest pullout strength in all foam grades (p<.05). CONCLUSIONS Pedicle screw with an outer cylindrical and inner conical configuration with a V-shaped thread may have maximum pullout strength, regardless of bone density.
Collapse
Affiliation(s)
- Young-Yul Kim
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, The Catholic University of Korea, 64 Daeheung-ro, Daejeon, 301-723, Korea
| | | | | |
Collapse
|
21
|
Abstract
There are three basic concepts that are important to the biomechanics of pedicle screw-based instrumentation. First, the outer diameter of the screw determines pullout strength, while the inner diameter determines fatigue strength. Secondly, when inserting a pedicle screw, the dorsal cortex of the spine should not be violated and the screws on each side should converge and be of good length. Thirdly, fixation can be augmented in cases of severe osteoporosis or revision. A trajectory parallel or caudal to the superior endplate can minimise breakage of the screw from repeated axial loading. Straight insertion of the pedicle screw in the mid-sagittal plane provides the strongest stability. Rotational stability can be improved by adding transverse connectors. The indications for their use include anterior column instability, and the correction of rotational deformity.
Collapse
Affiliation(s)
- W Cho
- Department of Orthopaedic Surgery, University of Virginia, 114 Old Fifth Circle, Charlottesville, Virginia 22903, USA.
| | | | | |
Collapse
|
22
|
Effect of insertional temperature on the pullout strength of pedicle screws inserted into thoracic vertebrae: an in vitro calf study. Spine (Phila Pa 1976) 2008; 33:E667-72. [PMID: 18758347 DOI: 10.1097/brs.0b013e31817c4f9c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN The axial pullout strength of pedicle screws that were at different temperatures when inserted was compared in calf vertebrae. OBJECTIVE To determine if insertional temperature of the screw itself affects pullout strength. SUMMARY OF BACKGROUND DATA Fixation stability of pedicle screws depend on several factors. The development of alternate insertion techniques and screw designs were used to improve the stability. Polymethylmethacrylate and calcium sulfate augmentation have been shown to be viable options for improving fixation; but have the potential disadvantages. METHODS Three cadaveric thoracic calf spines were instrumented between T1-T10 bilaterally with one type of pedicle screws stored at different insertional temperatures. The axial pullout tests were performed at cross head speed of 5 mm/min. Pullout loads and displacement were recorded at 1/20 seconds intervals until failure occurred. RESULTS The highest pullout force was obtained with the screws inserted at 4 degrees C. These screws had a 19% increase in pullout strength compared with the screws inserted at 24 degrees C. The highest force/torque proportion was gained in the same group as 0.30 kn/Nm. CONCLUSION The technique showed increased pullout force with the screws inserted at 4 degrees C. Using pedicle screws stored at 4 degrees C before instrumentation, seems reasonable in an attempt to obtain a better bone-screw interface.
Collapse
|
23
|
Krenn MH, Piotrowski WP, Penzkofer R, Augat P. Influence of thread design on pedicle screw fixation. Laboratory investigation. J Neurosurg Spine 2008; 9:90-5. [PMID: 18590418 DOI: 10.3171/spi/2008/9/7/090] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECT The authors conducted a study to determine the thread properties that provide optimal screw fixation in cancellous bone, when screws of the same external screw diameter are used. METHODS Three compliance engineering-certified screws in clinical use, all of the same external diameter and length, were compared in an axial pullout experiment with respect to advantageous thread properties. As test material, standardized Sawbone blocks with 3 different densities (0.12, 0.16, and 0.32 g/cm3) were used. RESULTS Screw thread Type 1, whose flank overlap area (FOA; 261 mm2) results from narrowing the conical core in the thread area, showed significantly better holding strength than the other types. Screw thread Type 2 (FOA 326 mm2) with a conical but thicker core and a smaller thread pitch was found to be the only one without increase of pull-out forces when test materials density changed from 0.12 to 0.16 g/cm3. A screw tested as control, with a constant (cylindrical) core diameter (Type 3; FOA 206 mm2), had the same thread pitch as Type 1 but without the compressive effect on the surrounding bur hole wall material. Nevertheless, it showed higher pullout forces in the 0.16-g/cm3 material than screw Type 2. CONCLUSIONS By reducing the core diameter of a screw toward the tip, while maintaining a constant nominal (external) diameter, one achieves frictional connection due to compression of surrounding material. In addition, the FOA is increased, which, in summary, leads to better fixation, as shown by screw Type 1.
Collapse
Affiliation(s)
- Michael Hannes Krenn
- Department for Spine Surgery, Paracelsus Medical University Hospital, Salzburg, Austria.
| | | | | | | |
Collapse
|
24
|
Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses. ACTA ACUST UNITED AC 2008; 21:130-8. [PMID: 18391719 DOI: 10.1097/bsd.0b013e318073cc4b] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
STUDY DESIGN Comparative in vitro biomechanical study and finite element analysis. OBJECTIVES To investigate the bending strength and pullout strength of conical pedicle screws, as compared with conventional cylindrical screws. SUMMARY OF BACKGROUND DATA Transpedicle screw fixation, the gold standard of spinal fixation, is threatened by screw failure. Conical screws can resist screw breakage and loosening. However, biomechanical studies of bending strength have been lacking, and the results of pullout studies have varied widely. METHODS Ten types of pedicle screws with different patterns of core tapering and core diameter were specially manufactured with good control of all other design factors. The stiffness, yielding strength, and fatigue life of the pedicle screws were assessed by cantilever bending tests using high-molecular-weight polyethylene. The pullout strength was assessed by pullout tests using polyurethane foam. Concurrently, 3-dimensional finite element models simulating these mechanical tests were created, and the results were correlated to those of the mechanical tests. RESULTS In bending tests, conical screws had substantially higher stiffness, yielding strength, and fatigue life than cylindrical screws (P<0.01), especially when there was no step at the thread-shank junction. In pullout tests, pullout strength was higher in screws with a conical core and smaller core diameter and also in situations with higher foam density (P<0.01). In finite element analysis, the maximal deflection and maximal tensile stress were closely related to yielding strength (r=-0.91) and fatigue life (r=-0.95), respectively, in the bending analyses. The total reaction force was closely related to the pullout strength in pullout analyses (r=0.84 and 0.91 for different foam densities). CONCLUSIONS Conical screws effectively increased the bending strength and pullout strength simultaneously. The finite element analyses reliably predicted the results of the mechanical tests.
Collapse
|
25
|
Liu Q, Olson DR, Tiley FW, Shea M, Smits M, Hart RA. Biomechanical comparison of a novel multilevel hex-head pedicle screw design with a conventional head design. J Orthop Res 2007; 25:1115-20. [PMID: 17444509 DOI: 10.1002/jor.20401] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The objective of the study was to determine the biomechanical effect during insertion of multilevel hex-head design pedicle screws compared to a conventional screw-head design. Eighteen lumbar vertebrae and thoracic vertebrae from human cadavers were instrumented with a novel, multilevel hexagonal head pedicle screw on one side and a conventional head pedicle screw on the contralateral side. Screws were inserted at a constant rate and insertion and removal torques were recorded. A further 14 lumbar and thoracic vertebrae were used to test alterability of screw direction and operational effort required. Electromagnetic sensors recorded the change in angular direction for both screw and screwdriver. The force applied through the insertion screwdriver required to produce the directional change was also recorded. No significant differences were found between the two screw types for insertion or removal torque in either lumbar or thoracic vertebrae. Multilevel hex-head screws had significantly greater directional alterability than conventional head screws in both lumbar and thoracic specimens. Multilevel hex-head screws also required less force applied through the screwdriver than conventional screws to alter direction of screw insertion in both lumbar and thoracic specimens. The multilevel hex-head design did not affect the insertion or removal torque in comparison to a conventional head design.
Collapse
Affiliation(s)
- Qi Liu
- Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, 3181 SW Sam Jackson Park Road, Oregon 97239, USA
| | | | | | | | | | | |
Collapse
|
26
|
Lill CA, Schneider E, Goldhahn J, Haslemann A, Zeifang F. Mechanical performance of cylindrical and dual core pedicle screws in calf and human vertebrae. Arch Orthop Trauma Surg 2006; 126:686-94. [PMID: 16865403 DOI: 10.1007/s00402-006-0186-6] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2006] [Indexed: 10/24/2022]
Abstract
INTRODUCTION Failure of pedicle screws by loosening and back out remains a significant clinical problem. Pedicle screw fixation is determined by bone mineral density, pedicle morphology and screw design. The objective of this study was to compare the holding strength of newly developed dual core pedicle screws having a cylindrical design in terms of outer diameter and two cylindrical inner core regions connected by a conical transition with conventional cylindrical pedicle screws. MATERIALS AND METHODS Fifty bovine lumbar vertebrae and 40 human lumbar vertebrae were used. Five different screws were tested in nine experimental "settings" and ten specimens each. The screws were tested for cranial displacement and pullout strength before and after 5,000 cycles of cranio-caudal loading. The tests included a setting with fully inserted and 4 mm backed out screws. For statistical analysis the incomplete balanced block design was used. RESULTS Cyclic loading led to a decrease of pullout force between 24 and 31% and a 9% increase of displacement. The cylindrical screw designs were affected more than the dual core designs. The pullout force of cylindrical screws was smaller than of dual core screws. Even in a backed out condition dual core screws showed a significantly smaller displacement than cylindrical screws. CONCLUSION Pedicle screws with the dual core design provide good anchorage in the vertebra.
Collapse
Affiliation(s)
- C A Lill
- AO Research Institute Davos, Clavadelerstrasse, 7270 Davos, Switzerland.
| | | | | | | | | |
Collapse
|
27
|
Lei W, Wu Z. Biomechanical evaluation of an expansive pedicle screw in calf vertebrae. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2005; 15:321-6. [PMID: 15864667 PMCID: PMC3489295 DOI: 10.1007/s00586-004-0867-1] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2004] [Revised: 09/22/2004] [Accepted: 12/06/2004] [Indexed: 10/25/2022]
Abstract
The main objective of the present study is to evaluate biomechanically a newly designed expansive pedicle screw (EPS) using fresh pedicles from calf lumber vertebrae in comparison with conventional pedicle screws, (CDH) CD Horizon, Universal Spine System pedicle screw (USS) and Tenor (Sofamor Denek). Pull-out and turning-back tests were performed on these pedicle screws to compare their holding strength. Additionally, revision tests were undertaken to evaluate the mechanical properties of EPS as a "rescue" revision screw. A fatigue simulation test using a perpendicular load up to 1,500,000 cycles was also carried out. The results showed that the turning back torque (Tmax) and pull-out force (Fmax) of EPS screws were significantly greater than those of USS, Tenor and CDH screws (6.5x40 mm). In revision tests, the Fmax of both types of EPS screws (6.5x40 mm; 7.0x40 mm) were significantly greater than that of CDH, USS, and Tenor screws (P<0.05). Furthermore, no screws were broken or bent at the end of fatigue tests. The findings from the current study suggest that expansive pedicle screws can significantly improve the bone purchase and the pull-out strength compared to USS, Tenor and CDH screws of similar dimensions before and after a failure simulation.
Collapse
Affiliation(s)
- Wei Lei
- Fourth Military Medical University, Department of Orthopaedics, Xijing Hospital, Xi an, Shananxi Province, People’s Republic of China
| | - Zixiang Wu
- Fourth Military Medical University, Department of Orthopaedics, Xijing Hospital, Xian, Shananxi Province, People’s Republic of China
| |
Collapse
|
28
|
Jea A, Vanni S. Anterior correction of cervical spine lordosis using an adjustable depth tap: technical note. ACTA ACUST UNITED AC 2005; 18:178-81. [PMID: 15800437 DOI: 10.1097/01.bsd.0000154451.36450.df] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE In cases of multilevel anterior cervical spine decompression where intervening vertebral bodies need to be incorporated into the anterior plate construct, it may be difficult to apply the plate flush against the entire anterior cortical surface of the spine segment. Some have suggested using the levering property of bicortical screws to "pull" the body against the plate. Others have recommended contouring the anterior cervical plate with a plate bender. The objective of this work was to describe a novel technique using the adjustable depth tap provided in the Atlantis plating system for achieving cervical spine alignment against the lordotic plate after multilevel anterior decompression. METHODS We describe an illustrative case of a 14-year-old girl with complex cervical spine fractures after trauma. We used the 4.0-mm adjustable depth tap in the Atlantis plating system to lever the C4 body against the premachined lordotic plate. RESULTS Cervical lordosis and anterior cervical plate placement were accomplished after multilevel anterior cervical decompression with the use of an adjustable depth tap. CONCLUSIONS Bicortical screw placement and plate bending have drawbacks in trying to apply the anterior cervical plate firmly to the anterior surface of the cervical spine. We describe a new and safe technique of using an adjustable depth tap for achieving that same goal without any obvious drawbacks.
Collapse
Affiliation(s)
- Andrew Jea
- Department of Neurological Surgery, University of Miami School of Medicine, Miami, FL 33136, USA
| | | |
Collapse
|
29
|
Pitzen TR, Zenner S, Barbier D, Georg T, Steudel WI. Factors affecting the interface of cervical spine facet screws placed in the technique by Roy-Camille et al. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2004; 13:524-9. [PMID: 15048563 PMCID: PMC3476602 DOI: 10.1007/s00586-004-0685-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2003] [Revised: 12/18/2003] [Accepted: 01/17/2004] [Indexed: 11/24/2022]
Abstract
The objective of the study was to investigate the influence of bone cement, length of burr hole and bone density on pullout force and insertional screw torque of cervical spine facet screws. Both facets of 24 human cervical vertebrae were scanned for bone mineral density (BMD) and assigned to two groups for measuring of insertional screw torque and pullout strength. Maximal insertional screw torque was measured and removal of the screws was performed in displacement control (0.25 mm/s) without bone cement (PMMA), with 0.1 ml of PMMA and with the burr hole completely filled with PMMA. Screw torque was 59.1 N cm (+/-25.7 N cm), pullout force was 382.8 N (+/-140.5 N) without PMMA. Injection of 0.1 ml PMMA did not change significantly both screw torque (p=0.73) and pullout (p=0.129). Filling of the burr holes with PMMA increased significantly both screw torque (p<0.0001) and pullout force (p=0.028) when compared with injection of 0.1 ml of PMMA. A positive, moderate correlation was seen between BMD and screw torque before (r=0.501; p=0.097) and after filling with PMMA (r=0.514; p=0.088), BMD and pullout force before (r=0.441; p=0.152) and after complete filling with PMMA (r=0.673; p=0.047). The PMMA does increase both screw torque (p<0.0001) and pullout force (p=0.028) of facet screws significantly if the burr hole is filled with PMMA completely when compared with injection of 0.1 ml PMMA. Bone mineral density of the cervical facets moderately correlates with peak insertional torque and pullout force. This is true for a facet without PMMA and for a facet filled with PMMA. The length of the burr hole seems to be less important.
Collapse
Affiliation(s)
- T R Pitzen
- Neurochirurgische Klinik, Universitätsklinik des Saarlandes, 66421 Homburg, Germany.
| | | | | | | | | |
Collapse
|
30
|
Fogel GR, Reitman CA, Liu W, Esses SI. Physical characteristics of polyaxial-headed pedicle screws and biomechanical comparison of load with their failure. Spine (Phila Pa 1976) 2003; 28:470-3. [PMID: 12616159 DOI: 10.1097/01.brs.0000048652.45964.2e] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Pedicle screw strength or load to failure was biomechanically evaluated, and the geometric characteristics of pedicle screw instrumentation systems were compared. OBJECTIVES To compare the features of pedicle screw systems, and to demonstrate the failure point of the polyaxial pedicle screw head. SUMMARY OF BACKGROUND DATA Many pedicle screw instrumentation systems are currently available to the spine surgeon. Each system has its unique characteristics. It is important for the surgeon to understand the differences in these pedicle screw systems. Pedicle screw load to failure has not been subjected to a comparison study. METHODS The physical characteristics of each pedicle screw instrumentation system were determined. Features of rods, instruments, and pedicle screws were cataloged. Biomechanical testing of the pedicle screw construct was performed to determine the site and force of the load to failure. Nine pedicle screw systems were evaluated. Testing was performed with a pneumatic testing system under load control. Three polyaxial screws were used for each test at a load rate of 100 N/second. The load failure value was the force at which the pedicle screw or polyaxial head-screw interface initially deflected. RESULTS Biomechanical testing demonstrated in all instances that the polyaxial head coupling to the screw was the first failure point. Although there have been subtle design differences in the instruments over time, the features of the pedicle screw instrument sets have become remarkably similar. CONCLUSIONS Biomechanical pedicle screw load-to-failure data demonstrated that the polyaxial head coupling to the screw is the first to fail and may be a protective feature of the pedicle screw, preventing pedicle screw breakage. Knowing the physical characteristics of the available pedicle screw instrumentation systems may allow the choice of pedicle screw best suited for a given clinical situation.
Collapse
Affiliation(s)
- Guy R Fogel
- Department of Orthopedic Surgery, Baylor College of Medicine, Houston, Texas 77030, USA
| | | | | | | |
Collapse
|