• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4622124)   Today's Articles (22003)   Subscriber (49405)
For: Tiukinhoy S, Bhoopalam S, Winkelmann JW, Ammar K, Mangulabnan L, Reddy G, Fernandez A, Block R, Malhotra V, Feinstein S. Loss of contrast intensity during systole in the left ventricular cavity with the use of the contrast agent Albunex. An analysis of its correlation with pressure and velocity. Invest Radiol 1996;31:415-22. [PMID: 8818781 DOI: 10.1097/00004424-199607000-00004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Number Cited by Other Article(s)
1
Improvement of Detection Sensitivity of Microbubbles as Sensors to Detect Ambient Pressure. SENSORS 2018;18:s18124083. [PMID: 30469461 PMCID: PMC6308843 DOI: 10.3390/s18124083] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 11/14/2018] [Accepted: 11/19/2018] [Indexed: 01/16/2023]
2
Li F, Wang L, Fan Y, Li D. Simulation of noninvasive blood pressure estimation using ultrasound contrast agent microbubbles. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2012;59:715-726. [PMID: 22547282 DOI: 10.1109/tuffc.2012.2249] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
3
Greim CA, Broscheit JA, Lorenz KW, Thiel H, Roewer N. Intracavitary contrast intensity after transpulmonary transmission of a second-generation contrast agent at normal and reduced myocardial contractility. J Am Soc Echocardiogr 2000;13:1030-7. [PMID: 11093106 DOI: 10.1067/mje.2000.108537] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
4
Rubin DN, Thomas JD. New imaging technology: measurement of myocardial perfusion by contrast echocardiography. Coron Artery Dis 2000;11:221-6. [PMID: 10832555 DOI: 10.1097/00019501-200005000-00004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
5
Hausnerova E, Gottdiener JS, Gould JJ, Pezzullo JC, Callahan JD, Cohen JL, Bruns DE, Kuvelas MT, West HE, Dittrich HC. Differing susceptibility of echocardiographic contrast agents to adverse effects of biologic factors: multicenter, videodensitometric comparison of octafluoropropane-filled microspheres with air-filled microspheres for left ventricular opacification. J Am Soc Echocardiogr 1999;12:957-66. [PMID: 10552357 DOI: 10.1016/s0894-7317(99)70149-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
6
Haggag KJ, Russell D, Brucher R, Dahl A, Jakobsen J, Bakke S, Muan B. Contrast enhanced pulsed Doppler and colour-coded duplex studies of the cranial vasculature. Eur J Neurol 1999;6:443-8. [PMID: 10362897 DOI: 10.1046/j.1468-1331.1999.640443.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
7
Main ML, Asher CR, Rubin DN, Odabashian JA, Cardon LA, Thomas JD, Klein AL. Comparison of tissue harmonic imaging with contrast (sonicated albumin echocardiography and Doppler myocardial imaging for enhancing endocardial border resolution. Am J Cardiol 1999;83:218-22. [PMID: 10073824 DOI: 10.1016/s0002-9149(98)00844-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
8
Cohen JL, Cheirif J, Segar DS, Gillam LD, Gottdiener JS, Hausnerova E, Bruns DE. Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent. Results of a phase III Multicenter Trial. J Am Coll Cardiol 1998;32:746-52. [PMID: 9741522 DOI: 10.1016/s0735-1097(98)00311-8] [Citation(s) in RCA: 235] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
9
Karasch T, Rubin J. Diagnosis of renal artery stenosis and renovascular hypertension. EUROPEAN JOURNAL OF ULTRASOUND : OFFICIAL JOURNAL OF THE EUROPEAN FEDERATION OF SOCIETIES FOR ULTRASOUND IN MEDICINE AND BIOLOGY 1998;7 Suppl 3:S27-39. [PMID: 9673331 DOI: 10.1016/s0929-8266(98)00029-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA