1
|
John J, Singh V P P, Karuveettil V, M R, Subramanian D, Haridas K. Comparison of crack formation induced by ultrasonic tips and burs during root-end preparation: a systematic review and meta-analysis. Evid Based Dent 2022:10.1038/s41432-022-0823-0. [PMID: 36434118 DOI: 10.1038/s41432-022-0823-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Accepted: 12/02/2021] [Indexed: 06/16/2023]
Abstract
Introduction The main objective of root canal treatment is to achieve apical seal. Crack formation during root-end preparation promotes bacterial penetration, thereby leading to failure. This systematic review aims to examine the literature and summarise studies that compare the crack formation induced by ultrasonic tips and burs during root-end preparation.Methods This systematic review and meta-analysis were reported and conducted according to the PRISMA guidelines. The online databases PubMed, Scopus, and Google Scholar were used for data search. In vitro and ex vivo studies conducted up to March 2021 in the English language were included in the review. The risk of bias in the present study was assessed using a customised tool. A random-effects model was used for meta-analysis, χ² values and I² values were used to assess statistical heterogeneity. Meta-analysis was performed using RevMan software Version 5.4.Results A total of 317 records were found from all of the databases and one article was added following hand-searching. Twelve articles were included in the study after the application of the eligibility criteria of which ten articles were included for the meta-analysis. Nine studies showed a medium risk of bias while three studies showed a high risk of bias. The analysis of the crack formation showed a statistically significant difference between the ultrasonic tip and the bur (P = 0.0002). The odds ratio was 2.72 (1.60, 4.65) with a confidence interval of 95% suggesting higher odds of crack formation in the ultrasonic group.Conclusion This review concludes that ultrasonic root-end preparation resulted in higher crack formation than burs.
Collapse
Affiliation(s)
- Jesseca John
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India.
| | - Prabath Singh V P
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| | - Vineetha Karuveettil
- Department of Public Health Dentistry, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| | - Remya M
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| | - Deepthy Subramanian
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| | - Kaushik Haridas
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| |
Collapse
|
2
|
De-Deus G, Souza EM, Silva EJNL, Belladonna FG, Simões-Carvalho M, Moreira Cavalcante D, Versiani MA. A critical analysis of research methods and experimental models to study root canal fillings. Int Endod J 2022; 55 Suppl 2:384-445. [PMID: 35226760 DOI: 10.1111/iej.13713] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 02/21/2022] [Accepted: 02/21/2022] [Indexed: 11/28/2022]
Abstract
Canal filling materials and techniques have been one of the most studied topics in Endodontics. A simple search using the mesh term "root canal filling" in PubMed revealed more than 11,000 articles, an impressive number that is much higher than "root canal disinfection" (5,544 articles) or even the popular "root canal preparation" (8,527 articles). The overriding importance attributed to root filling procedures is not merely intuitive. It derived from the appealing relevance given by the appearance of the white lines in common radiographs grounded on retrospective clinical data that had identified the quality of a root filling as one of the major causes of treatment failure (lack of healing). Since the publication of the Washington study, impressive efforts have been made for the release of new materials and techniques, as well as, for the development of a plethora of laboratory methods to assess the quality of root filling procedures. This narrative review aims to address and discuss the most relevant laboratory methods to assess the root canal filling. Since filling quality improvements have not translated into higher success rates, as reported in longitudinal clinical studies, more than to deliver a simple methodology-based review, this paper aims to present an in-depth critical view on the assessment of laboratory methods used to study the filling materials and techniques. Recent data indicate that the long-term dimensional stability/degradation over time of endodontic sealers plays a central role in the treatment outcome. In this context, laboratory methods should be developed focusing on predicting, at least to some degree, the long-term clinical behaviour of root canal fillings, rather than simply ranking different materials or techniques.
Collapse
Affiliation(s)
- Gustavo De-Deus
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Erick Miranda Souza
- Department of Dentistry II, Federal University of Maranhão, São Luís, Maranhão
| | - Emmanuel João Nogueira Leal Silva
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.,Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | | | - Marco Simões-Carvalho
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | | | | |
Collapse
|
3
|
Heberer MT, Roggendorf HC, Faber FJ, Lawrenz NA, Frankenberger R, Roggendorf MJ. Longitudinal craze line propagation in human root dentin after instrumentation with NiTi rotary files of different instrument tapers after long-term chewing simulation. Clin Oral Investig 2021; 26:2671-2679. [PMID: 34787719 PMCID: PMC8898247 DOI: 10.1007/s00784-021-04238-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Accepted: 10/15/2021] [Indexed: 11/26/2022]
Abstract
Objectives The aim of this study was to investigate whether file design and taper significantly influence microcrack initiation during machine preparation. Materials and methods Sixty extracted teeth with straight single canals were selected. The teeth were randomly assigned to four groups based on their root canal anatomy and the corresponding NiTi rotary file system (I, Mtwo; II, ProTaper Universal; III, F6 SkyTaper; control, no preparation and filling). The root canals of the experimental groups were filled using the single-cone technique. The tested teeth were all subjected to a mechanical chewing simulation with flat lead loading over a period of 3 years (corresponding to 150,000 cycles). The teeth were checked for dentinal defects (accumulative crack growth in length) under the digital microscope (Keyence VHX-5000) at time 0 (baseline prior to chewing simulation) and after 3, 6, 12, 24, and 36 months of loading. The cumulative crack increase was statistically analyzed using the Kruskal–Wallis test, Jonckheere–Terpstra test, and the Wilcoxon rank-sum test. The significance was set at p < 0.05. Results In contrast to preparation with greater-tapered instruments, ProTaper Universal (group II) and F6 SkyTaper (group III) instrumentation with the smaller tapered Mtwo files (group I) showed less accumulative propagation of craze lines (p < 0.05) at all time points. Conclusion Instruments with greater taper for root canal instrumentation should be used with care to avoid negative long-term effects in the form of propagation of dentinal defects over time. A positive cutting-edge angle and a smaller taper have a positive effect on a lower craze line development. Clinical relevance Instruments with a positive cutting-edge angle and a smaller taper are beneficial for the long-term preservation of dentinal tooth structure.
Collapse
Affiliation(s)
- Marie-Therese Heberer
- Department of Operative Dentistry, Endodontics, and Pediatric Dentistry, Philipps University Marburg and University Hospital Giessen and Marburg, Campus Marburg, Georg-Voigt-Straße 3, 35039, Marburg, Germany.
| | - Hubert C Roggendorf
- Interdisciplinary Department of Oral Surgery an Implantology, University of Cologne, Kerpener Straße 32, 50931, Cologne, Germany
| | - Franz-Josef Faber
- Pre-Clinical Department, University of Cologne, Kerpener Straße 32, 50931, Cologne, Germany
| | - Nicolai-Alexander Lawrenz
- Department of Mathematics and Computer Science, Philipps University of Marburg, Hans-Meerwein-Straße 6, 35043, Marburg, Germany
| | - Roland Frankenberger
- Department of Operative Dentistry, Endodontics, and Pediatric Dentistry, Philipps University Marburg and University Hospital Giessen and Marburg, Campus Marburg, Georg-Voigt-Straße 3, 35039, Marburg, Germany
| | - Matthias J Roggendorf
- Department of Operative Dentistry, Endodontics, and Pediatric Dentistry, Philipps University Marburg and University Hospital Giessen and Marburg, Campus Marburg, Georg-Voigt-Straße 3, 35039, Marburg, Germany
| |
Collapse
|
4
|
de Sá MAB, Nunes E, Antunes ANDG, Brito Júnior M, Horta MCR, Amaral RR, Cohen S, Silveira FF. Push-out bond strength and marginal adaptation of apical plugs with bioactive endodontic cements in simulated immature teeth. Restor Dent Endod 2021; 46:e53. [PMID: 34909417 PMCID: PMC8636078 DOI: 10.5395/rde.2021.46.e53] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 10/18/2020] [Accepted: 10/22/2020] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVES This study evaluates the bond strength and marginal adaptation of mineral trioxide aggregate (MTA) Repair HP and Biodentine used as apical plugs; MTA was used as reference material for comparison. MATERIALS AND METHODS A total of 30 single-rooted teeth with standardized, artificially created open apices were randomly divided into 3 groups (n = 10 per group), according to the material used to form 6-mm-thick apical plugs: group 1 (MTA Repair HP); group 2 (Biodentine); and group 3 (white MTA). Subsequently, the specimens were transversely sectioned to obtain 2 (cervical and apical) 2.5-mm-thick slices per root. Epoxy resin replicas were observed under a scanning electron microscope to measure the gap size at the material/dentin interface (the largest and smaller gaps were recorded for each replica). The bond strength of the investigated materials to dentin was determined using the push-out test. The variable bond strengths and gap sizes were evaluated independently at the apical and cervical root dentin slices. Data were analyzed using descriptive and analytic statistics. RESULTS The comparison between the groups regarding the variables' bond strengths and gap sizes showed no statistical difference (p > 0.05) except for a single difference in the smallest gap at the cervical root dentin slice, which was higher in group 3 than in group 1 (p < 0.05). CONCLUSIONS The bond strength and marginal adaptation to root canal walls of MTA HP and Biodentine cement were comparable to white MTA.
Collapse
Affiliation(s)
| | - Eduardo Nunes
- Department of Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | | | | | | | - Rodrigo Rodrigues Amaral
- Department of Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Stephen Cohen
- Department of Endodontics, Arthur School of Dentistry, University of the Pacific, San Francisco, CA, USA
| | - Frank Ferreira Silveira
- Department of Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| |
Collapse
|
5
|
An Update on Endodontic Microsurgery of Mandibular Molars: A Focused Review. ACTA ACUST UNITED AC 2021; 57:medicina57030270. [PMID: 33809673 PMCID: PMC8002302 DOI: 10.3390/medicina57030270] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 03/03/2021] [Accepted: 03/12/2021] [Indexed: 11/17/2022]
Abstract
Endodontic microsurgery is a highly predictable treatment option in most cases when conventional endodontic treatment is not feasible. Nevertheless, mandibular molars are still considered by clinicians to be the most difficult type of teeth, with the lowest success rate. In recent years, endodontic microsurgery has been attempted more frequently with the emergence of modern cutting-edge technologies such as dental operating microscopes, various microsurgical instruments, and biocompatible materials, and the success rate is increasing. This review describes the current state of the art in endodontic microsurgical techniques and concepts for mandibular molars. Notably, this review highlights contemporary equipment, technology, and materials.
Collapse
|
6
|
Ling Z, Zheng Z, Zeng Y, Jiang L, Wu Y, Wu B, Yan W. Effect of Heat Softening versus Ultrasonic Removal of Root-End Gutta-Percha on the Quality of Root-End Preparation for Endodontic Microsurgery. SCANNING 2021; 2021:8320234. [PMID: 34405033 PMCID: PMC8355974 DOI: 10.1155/2021/8320234] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 06/15/2021] [Accepted: 07/09/2021] [Indexed: 05/05/2023]
Abstract
This study is aimed at comparing the efficacy of heat softening and ultrasonic removal of root-end gutta-percha during retrograde preparation for root apical microsurgery. Recently extracted single-rooted premolars (n = 40) were prepared with standardized endodontically treated and root-end resection and then randomly divided into four groups that received root-end cavity preparation using four different instruments: a diamond-coated ultrasonic tip (AS3D; SACTEON, Paris, France), AS3D with the modified plugger of cordless heat carrier (MSE; B&L Biotech, Bala Cynwyd, PA, USA), stainless steel ultrasonic tip (Jetip-2; B&L Biotech, Bala Cynwyd, PA, USA), or Jetip-2 with MSE. The time required for root-end preparation was recorded. The root apex samples were examined by scanning electron microscopy to assess root surface microcracks and marginal integrity. The remnants of gutta-percha on the cavity walls were evaluated using a stereomicroscope. Statistical analysis was performed using Student's t-test and Wilcoxon rank-sum test (P < 0.05). Usage of MSE with Jetip-2 significantly reduced preparation time from 99.8 ± 6.8 s to 32.4 ± 1.0 s (P = 0.009), the number of microcracks from 42 to 13 (P = 0.036), and the remnants of gutta-percha from 80% to 20% (P = 0.041). Similar results were observed for AS3D with MSE. The heat softening of MSE was effective in cleaning gutta-percha, thus greatly improving the efficiency of the root-end preparation, thereby producing a root-end cavity with fewer microcracks and better marginal integrity.
Collapse
Affiliation(s)
- Zhiting Ling
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou 510515, China
| | - Ziting Zheng
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou 510515, China
| | - Yuting Zeng
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou 510515, China
| | - Lifang Jiang
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou 510515, China
| | - Yuan Wu
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou 510515, China
| | - Buling Wu
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou 510515, China
| | - Wenjuan Yan
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou 510515, China
| |
Collapse
|
7
|
Palma PJ, Marques JA, Casau M, Santos A, Caramelo F, Falacho RI, Santos JM. Evaluation of Root-End Preparation with Two Different Endodontic Microsurgery Ultrasonic Tips. Biomedicines 2020; 8:biomedicines8100383. [PMID: 32998221 PMCID: PMC7601836 DOI: 10.3390/biomedicines8100383] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 09/19/2020] [Accepted: 09/25/2020] [Indexed: 02/06/2023] Open
Abstract
The aim of this study is to compare root-end preparation performed with two different ultrasonic tips-CVDentus and NSK-and respective time requirements. After root-end resection, 32 teeth were randomly divided in two groups, according to the ultrasonic tip used for root-end preparation. Preparation time was recorded. Photomicrographs were taken to assess the following parameters: root surface microcracking, marginal integrity and presence of debris. One ultrasonic tip from each group was analyzed through scanning electron microscopy before and after root-end preparation. The significance level was set at α = 0.05. Incidence of microcracks in both groups was 12.5%. Solely intracanal microcracking was found, consistently positioned within the widest side of the remaining dentine. No statistically significant differences were verified between both experimental groups regarding marginal integrity (p = 0.102) and preparation time (p = 0.780), whereas statistical differences (p = 0.003) were found concerning the presence of debris (the minimum registered score was mostly verified in CVDentus group). NSK tips showed major morphological changes, with extensive surface wear and noticeable loss of particles, which was not verified on CVDentus tips. Our findings suggest significant differences regarding root-end preparation walls quality, with CVDentus tips showing better results. Concerning microcracking, as well as preparation time and marginal integrity, both ultrasonic tips showed similar results. Qualitative analysis exposed NSK tips major morphological changes and wear after use, which was not verified on CVDentus tips.
Collapse
Affiliation(s)
- Paulo J. Palma
- Institute of Endodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal; (J.A.M.); (J.M.S.)
- Center for Innovation and Research in Oral Sciences (CIROS), Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal
- Correspondence: ; Tel.: +351-239-249-151
| | - Joana A. Marques
- Institute of Endodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal; (J.A.M.); (J.M.S.)
| | - Margarida Casau
- Dentistry Department, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal; (M.C.); (A.S.)
| | - André Santos
- Dentistry Department, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal; (M.C.); (A.S.)
| | - Francisco Caramelo
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Laboratory of Biostatistics and Medical Informatics (LBIM), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra, Portugal;
| | - Rui I. Falacho
- Institute of Oral Implantology and Prosthodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal;
| | - João Miguel Santos
- Institute of Endodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal; (J.A.M.); (J.M.S.)
- Center for Innovation and Research in Oral Sciences (CIROS), Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal
| |
Collapse
|
8
|
Effects of Dimensions of Root-End Fillings and Peripheral Root Dentine on the Healing Outcome of Apical Surgery. Eur Endod J 2020; 4:49-56. [PMID: 32161887 PMCID: PMC7006549 DOI: 10.14744/eej.2019.76376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Accepted: 05/07/2019] [Indexed: 11/20/2022] Open
Abstract
Objective: The objective of this study was to assess dimensions of root-end fillings (REFs), as well as peripheral root dentine (PRD) and their effects on the healing outcome of apical surgery. Methods: Cone beam computed tomography (CBCT) scans were utilized to measure the REF length and width and the PRD thickness in 61 roots of 53 teeth 1 year after apical surgery. Measurements were taken in the mesio-distal as well as bucco-lingual directions. The REF alignment with respect to the root axis was also evaluated. In addition, the dimensions of REF and PRD were assessed for possible correlations with the healing outcome. Criteria for determining the healing outcome included clinical and radiographic parameters. Results: The mean REF length was 2.02±0.52 mm. No significant differences were observed with regard to tooth groups, but one-canal roots had a significantly longer mean REF than two-canal roots (P=0.006). The mean REF widths were 1.14±0.24 mm mesio-distally and 2.61±1.24 mm bucco-lingually. Roots with two canals presented a significantly wider REF (P<0.001) in the bucco-lingual dimension but had a significantly narrower REF in the mesio-distal direction (P<0.001) compared to roots with single canals. PRD measured on average 1.19±0.23 mm at the resection level and 1.44±0.27 mm at the coronal end of the REF. Almost all REFs were perfectly aligned with the longitudinal axis of the roots. With regard to healing outcomes, no correlations were found with REF and PRD values, respectively. Conclusion: The mean REF length was 2.02 mm. On average, a thickness >1 mm of peripheral root dentine was maintained. The REF or PRD dimensions had no statistical effect on the healing outcome.
Collapse
|
9
|
Hegde MN, Honap MN, Narayanan S. Evaluation of surface integrity of root end cavities prepared using conventional and piezoelectric devices: A scanning electron microscopy study. Indian J Dent Res 2019; 30:772-776. [PMID: 31854372 DOI: 10.4103/ijdr.ijdr_237_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Introduction An array of factors control the success of endodontic surgery. One of them is the technique used to prepare the root end cavities which is conventionally being done with burs. In past decades, ultrasonic instruments have been introduced for the same. Studies comparing these instruments on root surface integrity are scarce. Thus, an in-vitro Scanning Electron Microscopy study was designed to evaluate the surface integrity of root end cavities prepared using conventional and piezoelectric devices. Methodology Twelve single-rooted human intact mandibular premolar teeth were endodontically treated and included in the study. They were divided into two groups. In the first group, 3 mm root-end cavities were prepared using conventional retro preparation burs and in the second group, 3 mm root-end cavities were prepared using piezoelectric retro-tips. The specimens were coded for blind evaluation and analysed under scanning electron microscope at 100x, 500x and 1000x magnification for smear layer and debris. Gutmann's scoring criteria was followed to score the specimens. Statistical analysis was carried out using Shapiro Wilk test and the independent sample t-test was used to check mean differences between variables. Results It was noted that significant statistical differences existed in mean debris and smear layer scores (p< 0.001) between the two groups. In the piezoelectric group, significantly lower debris layer and smear layer was found, compared to the conventional bur group. Conclusion Root-end cavities prepared using piezo retrotips produced cleaner, well-centered and more conservative surface with minimal debris & smear layer, compared to root-end cavities prepared using conventional burs.
Collapse
Affiliation(s)
- Mithra N Hegde
- Department of Conservative Dentistry and Endodontics, A B Shetty Memorial Institute of Dental Sciences, Mangalore, Karnataka, India
| | - Manjiri Nagesh Honap
- Department of Conservative Dentistry and Endodontics, A B Shetty Memorial Institute of Dental Sciences, Mangalore, Karnataka, India
| | - Sreenath Narayanan
- Department of Conservative Dentistry and Endodontics, A B Shetty Memorial Institute of Dental Sciences, Mangalore, Karnataka, India
| |
Collapse
|
10
|
Sachdeva N, Nikhil V, Jha P. Effect of ultrasonic root-end cavity preparation on dentinal microcrack formation: A micro-computed tomography study. J Conserv Dent 2019; 22:362-366. [PMID: 31802820 PMCID: PMC6873600 DOI: 10.4103/jcd.jcd_67_19] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Background: Root-end preparation during surgical endodontics may produce dentinal microcrack formation and/or propagation, leading to vertical root fractures. Aim: This study aimed to evaluate and compare the microcrack formation and propagation during ultrasonic root-end cavity preparation, with diamond- and zirconium nitride-coated tips using micro-computed tomography (CT). Methodology: Twenty-eight extracted, mature, free-of-defect, mandibular premolars were decoronated and micro-CT scanned for the presence of preexisting microcracks. Samples were prepared till F4, were obturated, and were re-scanned to determine an increase in the number of microcracks. After 3 mm of root-end resection, the samples were randomly divided for ultrasonic root-end preparation into Group 1 (n = 12): preparation was done with ProUltra Surg tip, Group 2 (n = 12): preparation was done with KiS tip, and Group 3 (n = 4): no preparation was done. The samples were rescanned, and data collected were analyzed using ANOVA and Student's t-test. The level of significance was set at 5%. Results: Preexisting microcracks were observed in few samples. The mean percentage number increase of microcracks after root-end preparation in ProUltra Surg group was 1.25 and in KiS group, it was 0.5. The difference in mean percentage increase for the number of microcracks after root-end cavity preparation using ProUltra Surg tip and KiS tip was 0.75. However, this difference was not statistically significant (P = 0.34). Conclusion: Both diamond- and zirconium nitride-coated ultrasonic tips resulted in more number of dentinal crack formation and propagation when preexisting cracks were present.
Collapse
Affiliation(s)
- Naina Sachdeva
- Department of Conservative Dentistry and Endodontics, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India
| | - Vineeta Nikhil
- Department of Conservative Dentistry and Endodontics, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India
| | - Padmanabh Jha
- Department of Conservative Dentistry and Endodontics, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India
| |
Collapse
|
11
|
Endal U, Shen Y, Ma J, Yang Y, Haapasalo M. Evaluation of Quality and Preparation Time of Retrograde Cavities in Root Canals Filled with GuttaCore and Cold Lateral Condensation Technique. J Endod 2018; 44:639-642. [DOI: 10.1016/j.joen.2017.11.023] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 11/29/2017] [Accepted: 11/30/2017] [Indexed: 11/29/2022]
|
12
|
Surgical endodontics: are the guidelines being followed? A pilot survey. Br Dent J 2018; 224:157-162. [PMID: 29371691 DOI: 10.1038/sj.bdj.2018.75] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/17/2017] [Indexed: 11/09/2022]
|
13
|
A. Versiani M, Souza E, De-Deus G. Critical appraisal of studies on dentinal radicular microcracks in endodontics: methodological issues, contemporary concepts, and future perspectives. ACTA ACUST UNITED AC 2015. [DOI: 10.1111/etp.12091] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Wan J, Deutsch AS, Musikant BL, Guzman J. Evaluation of the breakage of orthograde endodontic ultrasonic tips. J Endod 2014; 40:2074-6. [PMID: 25442727 DOI: 10.1016/j.joen.2014.09.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Revised: 08/26/2014] [Accepted: 09/16/2014] [Indexed: 11/19/2022]
Abstract
INTRODUCTION The objective of this study was to compare the breakage of 3 endodontic ultrasonic tips when removing dentin from extracted molars. METHODS Three tips were tested (n = 10): BUC 1A (Obtura Spartan, Fenton, MO), CPR 5D (Obtura Spartan), and EDS 5E (Essential Dental Systems, South Hackensack, NJ). Extracted molars were prepared and mounted to a slow-speed alternating-current motor of a custom testing apparatus, which provided a 5-mm linear movement at an approximate rate of 4 mm/s. A 20-g axial force was applied to the tooth specimens. The MiniEndo II Ultrasonic Unit (SybronEndo, Orange, CA) was used to operate the ultrasonic tips in 20-second cycles with 10 seconds of rest between each cycle. The process was repeated until breakage was observed or 10 minutes had elapsed. The time to breakage was recorded for each sample. Tips that did not break were assigned a breakage time of 10 minutes. RESULTS There was a statistically significant difference in breakage as a function of tip type (P = .0002). No EDS 5E tips were observed to break after 10 minutes of instrumentation. CONCLUSIONS Based on the results of the investigation, the EDS 5E tip is significantly more resistant to breakage than the other tips tested.
Collapse
Affiliation(s)
- Jeffrey Wan
- Essential Dental Laboratories, South Hackensack, New Jersey.
| | | | | | - Jason Guzman
- Essential Dental Laboratories, South Hackensack, New Jersey
| |
Collapse
|
15
|
Kwak SW, Moon YM, Yoo YJ, Baek SH, Lee W, Kim HC. Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study. Restor Dent Endod 2014; 39:276-81. [PMID: 25383346 PMCID: PMC4223097 DOI: 10.5395/rde.2014.39.4.276] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Accepted: 06/13/2014] [Indexed: 11/11/2022] Open
Abstract
Objectives The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods The apical 3-mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. Results There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.
Collapse
Affiliation(s)
- Sang-Won Kwak
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Young-Mi Moon
- Department of Conservative Dentistry, School of Dentistry, Daejeon Hospital, WonKwang University, Daejeon, Korea
| | - Yeon-Jee Yoo
- Department of Conservative Dentistry, School of Dentistry, Seoul National University, Dental Research Institute, Seoul, Korea
| | - Seung-Ho Baek
- Department of Conservative Dentistry, School of Dentistry, Seoul National University, Dental Research Institute, Seoul, Korea
| | - WooCheol Lee
- Department of Conservative Dentistry, School of Dentistry, Seoul National University, Dental Research Institute, Seoul, Korea
| | - Hyeon-Cheol Kim
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| |
Collapse
|
16
|
Gunes B, Aydinbelge HA. Effects of ultrasonic root-end cavity preparation with different surgical-tips and at different power-settings on glucose-leakage of root-end filling material. J Conserv Dent 2014; 17:476-80. [PMID: 25298652 PMCID: PMC4174711 DOI: 10.4103/0972-0707.139846] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2013] [Revised: 07/04/2013] [Accepted: 07/16/2014] [Indexed: 11/28/2022] Open
Abstract
Aim: The aim of this in vitro study was to evaluate the effects of different ultrasonic surgical-tips and power-settings on micro-leakage of root-end filling material. Materials and Methods: The root canals were instrumented using rotary-files and were filled with tapered gutta-percha and root canal sealer using a single-cone technique. The apical 3 mm of each root was resected and the roots were divided into six experimental groups; negative and positive control groups. Root-end cavities were prepared with diamond-coated, zirconum-nitride-coated and stainless-steel ultrasonic retro-tips at half-power and high-power settings. The time required to prepare the root-end cavities for each group was recorded. Root-end cavities were filled with Super-EBA. Leakage values of all samples evaluated with glucose penetration method on 7, 14, 21 and 28th days. The results were statistically analyzed with Kruskal-Wallis and Hollander-Wolfe tests. Results: The mean time required to prepare retro cavities using diamond-coated surgical tip at high-power setting was significantly less than other groups (P < 0.01). There were no statistically significant differences in the glucose penetration between the groups at first and second weeks (P > 0.01). Diamond-coated surgical tip showed the least leakage at high-power setting at 3rd and 4th weeks (P < 0.01). Conclusions: Under the conditions of this study, cavity preparation time was the shortest and the leakage of the root-end filling was the least when diamond-coated retro-tip used at high-power setting.
Collapse
Affiliation(s)
- Betul Gunes
- Department of Endodontics, Faculty of Dentistry, University of Osmangazi, Eskişehir, Turkey
| | - Hale Ali Aydinbelge
- Department of Endodontics, Faculty of Dentistry, University of Selcuk, Selcuklu-Konya, Turkey
| |
Collapse
|
17
|
Aydemir S, Cimilli H, Mumcu G, Chandler N, Kartal N. Crack Formation on Resected Root Surfaces Subjected to Conventional, Ultrasonic, and Laser Root-End Cavity Preparation. Photomed Laser Surg 2014; 32:351-5. [DOI: 10.1089/pho.2013.3696] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Seda Aydemir
- Department of Endodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey
| | - Hale Cimilli
- Department of Restrorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey
| | - Gonca Mumcu
- Faculty of Health Sciences, Marmara University, Istanbul, Turkey
| | - Nicholas Chandler
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Nevin Kartal
- Department of Restrorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey
| |
Collapse
|
18
|
Abella F, de Ribot J, Doria G, Duran-Sindreu F, Roig M. Applications of Piezoelectric Surgery in Endodontic Surgery: A Literature Review. J Endod 2014; 40:325-32. [DOI: 10.1016/j.joen.2013.11.014] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2013] [Revised: 11/14/2013] [Accepted: 11/20/2013] [Indexed: 01/11/2023]
|
19
|
Liu Z, Zhang D, Li Q, Xu Q. Evaluation of Root-end Preparation with a New Ultrasonic Tip. J Endod 2013; 39:820-3. [DOI: 10.1016/j.joen.2013.03.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2012] [Revised: 02/23/2013] [Accepted: 03/03/2013] [Indexed: 11/28/2022]
|
20
|
Aydemir S, Cimilli H, Yoruç ABH, Kartal N. Evaluation of two different root-end cavity preparation techniques: A scanning electron microscope study. Eur J Dent 2013; 7:186-190. [PMID: 24883024 PMCID: PMC4023193 DOI: 10.4103/1305-7456.110168] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE In this study, we aimed to evaluate and compare the dentinal walls of root-end cavities for the presence of cracks after cavity preparation using US retrotips and Er: YAG laser. MATERIALS AND METHODS Fifty single-rooted teeth were prepared by Protaper NiTi rotary system and obturated by lateral condensation. Three milimeters of root-end was resected. Twenty teeth were prepared with US retrotip (Group 1), 20 teeth with Er: YAG laser (Group 2), and 10 teeth without retropreparation (control group). The root-end surfaces were examined under a scanning electron microscope (SEM). Then the cracks of the resected root surfaces were evaluated on microphotographs. RESULTS No statistically significant difference was detected between US Group and Laser Group for complete, incomplete, intradentinal, and total number of cracks (P = 0.47, P = 0.80, P = 0.69, P = 0.869, respectively). CONCLUSION Statistical analysis revealed no significant effect of retropreparation technique on the development of apical cracks (P > 0.05).
Collapse
Affiliation(s)
- Seda Aydemir
- Department of Endodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkiye
| | - Hale Cimilli
- Department of Restrorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkiye
| | - Afife Binnaz Hazar Yoruç
- Department of Metallurgical and Materials Engineering, Yildiz Technical University, Istanbul, Turkiye
| | - Nevin Kartal
- Department of Restrorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkiye
| |
Collapse
|
21
|
Camargo Villela Berbert FL, de Faria-Júnior NB, Tanomaru-Filho M, Guerreiro-Tanomaru JM, Bonetti-Filho I, Leonardo RDT, Marcantonio RAC. An in vitro evaluation of apicoectomies and retropreparations using different methods. ORAL SURGERY, ORAL MEDICINE, ORAL PATHOLOGY, ORAL RADIOLOGY, AND ENDODONTICS 2010; 110:e57-63. [PMID: 20573528 DOI: 10.1016/j.tripleo.2010.03.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2009] [Revised: 03/02/2010] [Accepted: 03/03/2010] [Indexed: 10/19/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate: 1) the apical root surface, gutta-percha interface, and preparation time of root-end resections made with burs, ultrasound, or laser; and 2) the thickness of surrounding dentin after laser or ultrasonic root-end cavity preparation. STUDY DESIGN 1) Thirty root-filled teeth were resected as follows: Zekrya bur in group I, Chemical Vapor Deposition (CVD) ultrasonic tip (9.5107-8) in group II, and ErCr:YSGG (Waterlase) in group III. The preparation time was recorded. Replicas of the resected root-ends were examined under a scanning electron microscope (SEM). 2) Thirty root-filled teeth were submitted to apicectomies and root-end cavities were prepared by using: CVD (6.1107-6) ultrasonic retrotips (group IV), EMS (DT-060) ultrasonic retrotips (group V), and ErCr:YSGG laser tips (group VI). Replicas of the root apices were examined under a SEM. RESULTS There were no fissures or fractures on root-end surfaces. The bur produced the smoothest surface (P < .05). Group I had the lowest preparation time (P < .05). The best adaptation between the filling and the root canals walls was observed in group III, but it was not significantly different from group II (P < .05). No resected root-ends had cracks after preparation. Group VI showed the least minimum dentin thickness (P < .05). CONCLUSIONS The 3 methods evaluated did not cause any injury to the root-end surface, but they harmed the apical adaptation. Laser tips removed more dentin than ultrasonic retrotips and should be used with care to avoid overpreparation.
Collapse
|
22
|
Marchionni S, Baldissara P, Monaco C, Scotti R. A systematic method for predetermined scanning electron microscope analysis in dental science. SCANNING 2010; 32:97-103. [PMID: 20695027 DOI: 10.1002/sca.20185] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Scanning electron microscope evaluation could be criticized if the method adopted to correct for bias is not specified in the study design. Observers can draw conclusions from images unconsciously chosen to best support their research hypotheses, impairing the basic research principle of operator's impartiality. In this study, a systematic observation method has been described and verified for repeatability. The number and the observation points on a certain specimen have been predetermined using a scheme along with observation rules previously established in the research protocol. When our instrument is used at an operating magnification between 500x and 1,000x (corresponding to a frame of 250x190 micro and 120x90 micro, respectively), the method allowed 100% repeatable observation frames, with linear frame errors in finding an observation point of 12.5% in length and 16.8% in height. With modifications to accommodate research objective and statistical requirements, the method could be applied to many SEM observation study.
Collapse
Affiliation(s)
- Silvia Marchionni
- Department of Oral Sciences, Laboratory of Microscopy, Alma Mater Studiorum, University of Bologna, Bologna, Italy.
| | | | | | | |
Collapse
|
23
|
Rahimi S, Yavari HR, Shahi S, Zand V, Shakoui S, Reyhani MF, Pirzadeh A. Comparison of the effect of Er, Cr-YSGG laser and ultrasonic retrograde root-end cavity preparation on the integrity of root apices. J Oral Sci 2010; 52:77-81. [DOI: 10.2334/josnusd.52.77] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
|
24
|
Batista de Faria-Junior N, Tanomaru-Filho M, Guerreiro-Tanomaru JM, de Toledo Leonardo R, Camargo Villela Berbert FL. Evaluation of Ultrasonic and ErCr:YSGG Laser Retrograde Cavity Preparation. J Endod 2009; 35:741-4. [DOI: 10.1016/j.joen.2009.02.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2008] [Revised: 02/01/2009] [Accepted: 02/17/2009] [Indexed: 10/20/2022]
|
25
|
Bernardes RA, de Moraes IG, Garcia RB, Bernardineli N, Baldi JV, Victorino FR, Vasconcelos BC, Duarte MAH, Bramante CM. Evaluation of Apical Cavity Preparation With a New Type of Ultrasonic Diamond Tip. J Endod 2007; 33:484-7. [PMID: 17368345 DOI: 10.1016/j.joen.2006.12.019] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2006] [Revised: 12/10/2006] [Accepted: 12/24/2006] [Indexed: 11/26/2022]
Abstract
This study evaluated the time, occurrence of fracture, and quality of apical cavity preparation with three different ultrasonic diamond tips: Satelec, Trinity, and a new type, CVD (chemical vapor deposition), using scanning electron microscopy (SEM) analysis. Thirty human single-rooted premolars were selected, submitted to apicectomy, and prepared with ultrasonic tips; impressions were then obtained. The presence of fractures was evaluated on the impressions, and the quality of preparation was evaluated by SEM analysis of teeth and scoring by two examiners. The group prepared with the CVD tips exhibited the shorter preparation time and did not present fractures. There was no statistically significant difference in the quality of preparation for the three tips. The three brands of ultrasonic tips produced adequate grinding without altering the morphology of the apical foramen.
Collapse
Affiliation(s)
- Ricardo A Bernardes
- Department of Endodontics, Bauru Dental School, University of São Paulo, Al. Dr. Otávio Pinheiro Brisolla 9-75, CEP 17012-901 Bauru, SP, Brazil.
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Wallace JA. Effect of Waterlase laser retrograde root-end cavity preparation on the integrity of root apices of extracted teeth as demonstrated by light microscopy. AUST ENDOD J 2006; 32:35-9. [PMID: 16603044 DOI: 10.1111/j.1747-4477.2006.00006.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Most endodontists use ultrasonic instruments for retrograde root-end cavity preparations even though they have been found to produce cracks. In this laboratory study, thirty-six randomly chosen roots had root-end cavity preparations made with the Waterlase laser and only one questionable intra-canal crack was found. It was concluded that the Waterlase laser when used to make endodontic root-end cavity preparations produces either no cracks, or a very low percentage (2.8%) of cracks.
Collapse
Affiliation(s)
- James A Wallace
- School of Dental Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, USA.
| |
Collapse
|
27
|
Paz E, Satovsky J, Moldauer I. Comparison of the Cutting Efficiency of Two Ultrasonic Units Utilizing Two Different Tips at Two Different Power Settings. J Endod 2005; 31:824-6. [PMID: 16249728 DOI: 10.1097/01.don.0000158235.66791.17] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The objective of this in vitro study was to set up a testing protocol and utilize it to evaluate and compare the cutting efficiency of ultrasonic units. Evaluation of two ultrasonic units utilizing two different tips was done by measuring the weght of a dentin specimen before and after ultrasonic treatment for set time periods. The difference in weight was the amount of dentin removed. The ultrasonic units tested were the P5 Booster (Staelec, France) and the Spartan (Obtura-Spartan, Fenton, MO) machines. The tips tested were the CPR-2D and ETD20 types. The units were tested at maximum and medium power. All the experimental variables, ultrasonic unit type, power setting and tip type were found to have an effect on the cutting efficiency (P<0.0001). The P5 ultrasonic unit was more effective at dentin removal than the Spantan ultrasonic unit at both power settings. The ETD-20 tip was more effective at dentin removal than the CPR-2D tip on both units at both power settings.
Collapse
Affiliation(s)
- Ernesto Paz
- Department of Endodontics, Nova Southeastern University, Ft. Lauderdale, Florida 33328-2018, USA
| | | | | |
Collapse
|
28
|
Gondim E, Kim S, de Souza-Filho FJ. An investigation of microleakage from root-end fillings in ultrasonic retrograde cavities with or without finishing: A quantitative analysis. ACTA ACUST UNITED AC 2005; 99:755-60. [PMID: 15897864 DOI: 10.1016/j.tripleo.2004.08.019] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
29
|
De Bruyne MAA, De Moor RJG. SEM analysis of the integrity of resected root apices of cadaver and extracted teeth after ultrasonic root-end preparation at different intensities. Int Endod J 2005; 38:310-9. [PMID: 15876295 DOI: 10.1111/j.1365-2591.2005.00949.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
AIM To compare the integrity of root apices of cadaver and extracted teeth after resection, ultrasonic root-end cavity preparation at medium and low ultrasonic power settings and retrieval. METHODOLOGY Root canal treatment, perpendicular root-end resection and root-end preparation were performed on single-rooted anterior and premolar teeth (49 teeth in situ in maxillary and mandibular jaws from cadavers and 45 extracted teeth). Apical root-end cavities were prepared with the S12/90 degrees D tip and the Suni-Max ultrasonic unit (Satelec, Merignac, France) at the intensity prescribed by the manufacturer (power 7 at power mode S) (34 cadaver teeth, 30 extracted teeth) and at a lower intensity (power 4 at power mode S) (15 cadaver teeth, 15 extracted teeth). After ultrasonic preparation the cadaver teeth were retrieved from the jaws. Exaflex impressions (GC Corporation, Tokyo, Japan) were made of the root apices after resection, root-end preparation and retrieval. These impressions were processed for SEM analysis, and the recordings evaluated for cracks and marginal chipping. RESULTS In general, extracted teeth showed significantly more cracks and chipping than cadaver teeth. Lowering the ultrasonic power from medium to low intensity resulted in equal scores for cracks on extracted teeth and for chipping on cadaver teeth, in higher scores for cracks on cadavers and in lower scores for chipping on extracted teeth. Complete cracks and cracks originating from the root surface occurred only in extracted teeth. CONCLUSIONS The number of cracks and degree of chipping caused by ultrasonic root-end preparation was higher on extracted teeth than on cadaver teeth. Lowering the ultrasonic power from medium to low intensity cannot be recommended as it resulted in more cracks and equal chipping on cadaver teeth. Investigation of techniques and materials should be conducted in situ and not on extracted teeth.
Collapse
Affiliation(s)
- M A A De Bruyne
- Department of Operative Dentistry and Endodontology, Dental School, Ghent University, Ghent University Hospital, Gent, Belgium.
| | | |
Collapse
|
30
|
Taschieri S, Testori T, Francetti L, Del Fabbro M. Effects of ultrasonic root end preparation on resected root surfaces: SEM evaluation. ACTA ACUST UNITED AC 2004; 98:611-8. [PMID: 15529135 DOI: 10.1016/j.tripleo.2004.04.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVE The purpose of this study was to investigate the in vitro effect of ultrasonic retrotips on root end surfaces. STUDY DESIGN Root end resection was performed on 45 single-root teeth endodontically treated after extraction. Setting the ultrasonic device at full power, a retrograde cavity was made by a stainless steel tip in 9 specimens (SS-FP). In another 9 samples a diamond tip was used (D-FP). Setting the intensity of the ultrasonic device at half power, 9 specimens were treated using stainless steel tips (SS-HP) and 9 using diamond tip (D-HP). Nine teeth were only apically resected and used as controls. Histologic serial sections were examined by scanning electron microsope to assess the number of root-face cracking, the marginal quality, and the crack type. RESULTS No significant difference between diamond and stainless steel groups was found at a given power setting. Significant differences were found between SS-FP and SS-HP group for both the number of cracks and the marginal quality.
Collapse
Affiliation(s)
- Silvio Taschieri
- Section of Endodontics, Department of Odontology, Galeazzi Institute, University of Milano, Milan, Italy
| | | | | | | |
Collapse
|
31
|
Wright HM, Loushine RJ, Weller RN, Kimbrough WF, Waller J, Pashley DH. Identification of Resected Root-End Dentinal Cracks: A Comparative Study of Transillumination and Dyes. J Endod 2004; 30:712-5. [PMID: 15448465 DOI: 10.1097/01.don.0000125876.26495.20] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The dilemma of diagnosing and possibly treating dentinal cracks continues to present a challenge in endodontics. The purpose of this in vitro study was to compare the effectiveness of transillumination and dyes in identifying root-end dentinal cracks. Fifty maxillary central incisors were decoronated, and the canals were instrumented to an ISO size 50 at the working length. The apical 3 mm of the roots was resected, and cracks were artificially created in the apical dentin. Four independent examiners evaluated the root ends at x8 magnification with a surgical operating microscope using transillumination (group 1), sodium fluorescein dye (group 2), caries detect dye (group 3), methylene blue dye (group 4), and methylene blue plus transillumination (group 5). The examiners' ability to identify root ends correctly with and without cracks was analyzed by comparing the data with the predetermined standard (cracked and noncracked) using logistic regression analysis. All techniques used were shown to be more effective than random chance at diagnosing cracks. The areas under the curve of the different techniques were as follows: transillumination, 0.81 (95% confidence interval [CI], 0.69-0.93); sodium fluorescein, 0.72 (95% CI, 0.58-0.86); caries detector, 0.76 (95% CI, 0.63-0.89); methylene blue, 0.70 (95% CI, 0.55-0.84); and methylene blue plus transillumination, 0.82 (95% CI, 0.70-0.94). Thus, the crack assessment techniques that gave the best discrimination between cracked and noncracked specimens, regardless of rater, was methylene blue plus transillumination. This study emphasizes the usefulness of transillumination along with magnification in detecting dentinal cracks.
Collapse
Affiliation(s)
- Henry M Wright
- Department of Endodontics, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1244, USA
| | | | | | | | | | | |
Collapse
|
32
|
Gondim E, Zaia AA, Gomes BPFA, Ferraz CCR, Teixeira FB, Souza-Filho FJ. Investigation of the marginal adaptation of root-end filling materials in root-end cavities prepared with ultrasonic tips. Int Endod J 2003; 36:491-9. [PMID: 12823705 DOI: 10.1046/j.1365-2591.2003.00679.x] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIM To compare the surface topography of root apices following ultrasonic root-end preparation, and again after root-end fillings submitted to three different finishing techniques. METHODOLOGY Eighty-one root-end cavities prepared ultrasonically in human canines, were divided at random into three test groups of 27 each. The cavities were filled with Super-EBA, IRM, or ProRoot-MTA and finished by ball burnishing. Eighteen roots from each group received a final finish with either a 30-fluted tungsten carbide finishing bur, or a Zekrya carbide 28 mm bur after storage in water at 37 degrees C for 24 h. The root-end surface topographies were reproduced by means of polyvinylsiloxane impressions and epoxy resin replicas. Scanning electron micrography (SEM) images of each replica were taken prior to and after root-end filling. An image analysis system was used to compare the alteration of the marginal chipping areas and to calculate the gaps located in the dentine/root-end filling interface. RESULTS When a bur was used to finish the set materials, a significant (P < 0.05) area of marginal chipping was eliminated. The finishing technique did not significantly (P > 0.05) affect the incidence of gaps in groups root-end filled with MTA or IRM. Super-EBA and IRM retrofillings finished with a ball burnisher or a Zekrya bur displayed a significantly (P < 0.05) larger calculated gap area than roots filled with MTA. CONCLUSION Under this in vitro study, the marginal adaptation of MTA was good with or without finishing procedures. Applying a finishing bur over the condensed and set IRM and Super-EBA created better marginal adaptation.
Collapse
Affiliation(s)
- E Gondim
- Endodontic Unit, School of Dentistry of Piracicaba, State University of Campinas - UNICAMP, Piracicaba - SP, Brazil.
| | | | | | | | | | | |
Collapse
|