Gibson RN, Vincent JM, Speer T, Collier NA, Noack K. Accuracy of computed tomographic intravenous cholangiography (CT-IVC) with iotroxate in the detection of choledocholithiasis.
Eur Radiol 2004;
15:1634-42. [PMID:
15627178 DOI:
10.1007/s00330-004-2606-8]
[Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2004] [Revised: 11/12/2004] [Accepted: 11/16/2004] [Indexed: 11/28/2022]
Abstract
To determine the accuracy of computed tomographic intravenous cholangiography (CT-IVC) for detection of choledocholithiasis. Sixty-five patients undergoing endoscopic retrograde cholangiography (ERC) underwent CT-IVC prior to ERC, using a single detector helical CT following intravenous infusion of 100 ml iotroxate. Patients with bilirubin levels >3 times normal were excluded. ERC was indeterminate in three patients (4.7%) and CT-IVC in four (6.3%). Twenty-three patients had ductal calculi at ERC, and CT-IVC was positive in 22, with two false positives and one false negative: sensitivity 95.6%, specificity 94.3%. Stones were multiple in nine and solitary in 14. Of the 14 solitary stones, ten were <or=5 mm and eight were <or=4 mm. The bilirubin level in positive cases was within normal in 20. Maximum intensity projection (MIP) reformats showed stones in only 27% of cases and surface rendered (SR) reformats in none. CT-IVC is highly accurate for detection of ductal calculi, including single small calculi, with a normal or near normal serum bilirubin. Axial images should be used for interpretation rather than MIP or SR reformats.