1
|
Li J, Guan S, Cai B, Li Q, Rong S. Low molecular weight chitosan oligosaccharides form stable complexes with human lactoferrin. FEBS Open Bio 2023; 13:2215-2223. [PMID: 37872003 PMCID: PMC10699096 DOI: 10.1002/2211-5463.13722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 09/09/2023] [Accepted: 10/19/2023] [Indexed: 10/25/2023] Open
Abstract
Proteins in tears, including human lactoferrin (HLF), can be deposited and denatured on contact lenses, increasing the risk of microbial cell attachment to the lens and ocular complications. The surfactants currently used in commercial contact lens care solutions have low clearance ability for tear proteins. Chitosan oligosaccharide (COS) binds to a variety of proteins and has potential for use in protein removal, especially in contact lens care solutions. Here, we analyzed the interaction mechanism of COSs hydrolyzed from chitosan from different resources with HLF. The molecular weights (MWs) and concentrations of COSs were key factors for the formation of COS-HLF complexes. Lower MWs of COSs could form more stable COS-HLF complexes. COS from Aspergillus ochraceus had a superior effect on HLF compared with COS from shrimp and crab shell with the same MWs. In conclusion, COSs could bind to and cause a conformational change in HLF. Therefore, COSs, especially those with low MWs, have potential as deproteinizing agents in contact lens care solution.
Collapse
Affiliation(s)
- Juan Li
- Department of Bioengineering, School of Perfume and Aroma TechnologyShanghai Institute of TechnologyShanghaiChina
| | - Shimin Guan
- Department of Bioengineering, School of Perfume and Aroma TechnologyShanghai Institute of TechnologyShanghaiChina
| | - Baoguo Cai
- Department of Bioengineering, School of Perfume and Aroma TechnologyShanghai Institute of TechnologyShanghaiChina
| | - Qianqian Li
- Department of Bioengineering, School of Perfume and Aroma TechnologyShanghai Institute of TechnologyShanghaiChina
| | - Shaofeng Rong
- Department of Bioengineering, School of Perfume and Aroma TechnologyShanghai Institute of TechnologyShanghaiChina
| |
Collapse
|
2
|
Masoudi S, Willcox M. Development of an enzymatic method for the evaluation of protein deposition on contact lenses. BIOFOULING 2022; 38:84-99. [PMID: 35016572 DOI: 10.1080/08927014.2021.2019225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 12/09/2021] [Accepted: 12/10/2021] [Indexed: 06/14/2023]
Abstract
The aim of this study was to evaluate a new digestion method to quantify protein deposition on contact lenses. Four silicone hydrogel and one hydrogel contact lens material were incubated in lactoferrin, lysozyme, immunoglobulin A, and bovine serum albumin solutions at approximate physiological concentrations and temperature. Immobilized trypsin was used to digest the protein deposits from the contact lens surfaces. The total protein absorbed to lenses was extracted and digested using sequencing grade trypsin. The tryptic peptides were quantified using selected reaction monitoring mass spectrometry. The concentration of surface protein deposits was either lower than or the same as the total protein for all lens types and proteins. Immobilised trypsin can digest protein deposits from the surface of contact lenses. This ability to analyse the amount of protein at a contact lens surface may help in elucidating the effect of surface deposition on clinical outcomes during lens wear.
Collapse
Affiliation(s)
- Simin Masoudi
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
3
|
Jones L, Hui A, Phan CM, Read ML, Azar D, Buch J, Ciolino JB, Naroo SA, Pall B, Romond K, Sankaridurg P, Schnider CM, Terry L, Willcox M. CLEAR - Contact lens technologies of the future. Cont Lens Anterior Eye 2021; 44:398-430. [PMID: 33775384 DOI: 10.1016/j.clae.2021.02.007] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
Abstract
Contact lenses in the future will likely have functions other than correction of refractive error. Lenses designed to control the development of myopia are already commercially available. Contact lenses as drug delivery devices and powered through advancements in nanotechnology will open up further opportunities for unique uses of contact lenses. This review examines the use, or potential use, of contact lenses aside from their role to correct refractive error. Contact lenses can be used to detect systemic and ocular surface diseases, treat and manage various ocular conditions and as devices that can correct presbyopia, control the development of myopia or be used for augmented vision. There is also discussion of new developments in contact lens packaging and storage cases. The use of contact lenses as devices to detect systemic disease has mostly focussed on detecting changes to glucose levels in tears for monitoring diabetic control. Glucose can be detected using changes in colour, fluorescence or generation of electric signals by embedded sensors such as boronic acid, concanavalin A or glucose oxidase. Contact lenses that have gained regulatory approval can measure changes in intraocular pressure to monitor glaucoma by measuring small changes in corneal shape. Challenges include integrating sensors into contact lenses and detecting the signals generated. Various techniques are used to optimise uptake and release of the drugs to the ocular surface to treat diseases such as dry eye, glaucoma, infection and allergy. Contact lenses that either mechanically or electronically change their shape are being investigated for the management of presbyopia. Contact lenses that slow the development of myopia are based upon incorporating concentric rings of plus power, peripheral optical zone(s) with add power or non-monotonic variations in power. Various forms of these lenses have shown a reduction in myopia in clinical trials and are available in various markets.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong.
| | - Alex Hui
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | - Chau-Minh Phan
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| | - Michael L Read
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Dimitri Azar
- Department of Ophthalmology and Visual Sciences, University of Illinois College of Medicine, Chicago, IL, USA; Verily Life Sciences, San Francisco, CA, USA
| | - John Buch
- Johnson & Johnson Vision Care, Jacksonville, FL, USA
| | - Joseph B Ciolino
- Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA
| | - Shehzad A Naroo
- College of Health and Life Sciences, Aston University, Birmingham B4 7ET, UK
| | - Brian Pall
- Johnson & Johnson Vision Care, Jacksonville, FL, USA
| | - Kathleen Romond
- Department of Ophthalmology and Visual Sciences, University of Illinois College of Medicine, Chicago, IL, USA
| | - Padmaja Sankaridurg
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia; Brien Holden Vision Institute, Sydney, Australia
| | | | - Louise Terry
- School of Optometry and Vision Sciences, Cardiff University, UK
| | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| |
Collapse
|
4
|
Reduction of Physical Strength and Enhancement of Anti-Protein and Anti-Lipid Adsorption Abilities of Contact Lenses by Adding 2-Methacryloyloxyethyl Phosphorylcholine. Macromol Res 2020. [DOI: 10.1007/s13233-020-8149-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
5
|
The influence of protein deposition on contact lens tear film stability. Colloids Surf B Biointerfaces 2019; 180:229-236. [DOI: 10.1016/j.colsurfb.2019.04.051] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 04/18/2019] [Accepted: 04/24/2019] [Indexed: 11/22/2022]
|
6
|
Willcox MD. Tear film, contact lenses and tear biomarkers. Clin Exp Optom 2019; 102:350-363. [PMID: 31119796 DOI: 10.1111/cxo.12918] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Revised: 03/30/2019] [Accepted: 04/05/2019] [Indexed: 01/09/2023] Open
Abstract
This article summarises research undertaken since 1993 in the Willcox laboratory at the University of New South Wales, Sydney on the tear film, its interactions with contact lenses, and the use of tears as a source of biomarkers for ocular and non-ocular diseases. The proteome, lipidome and glycome of tears all contribute to important aspects of the tear film, including its structure, its ability to defend the ocular surface against microbes and to help heal ocular surface injuries. The tear film interacts with contact lenses in vivo and interactions between tears and lenses can affect the biocompatibility of lenses, and may be important in mediating discomfort responses during lens wear. Suggestions are made for follow-up research.
Collapse
Affiliation(s)
- Mark Dp Willcox
- School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
7
|
Korogiannaki M, Zhang J, Sheardown H. Surface modification of model hydrogel contact lenses with hyaluronic acid via thiol-ene "click" chemistry for enhancing surface characteristics. J Biomater Appl 2019; 32:446-462. [PMID: 28992804 DOI: 10.1177/0885328217733443] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Discontinuation of contact lens wear as a result of ocular dryness and discomfort is extremely common; as many as 26% of contact lens wearers discontinue use within the first year. While patients are generally satisfied with conventional hydrogel lenses, improving on-eye comfort continues to remain a goal. Surface modification with a biomimetic, ocular friendly hydrophilic layer of a wetting agent is hypothesized to improve the interfacial interactions of the contact lens with the ocular surface. In this work, the synthesis and characterization of poly(2-hydroxyethyl methacrylate) surfaces grafted with a hydrophilic layer of hyaluronic acid are described. The immobilization reaction involved the covalent attachment of thiolated hyaluronic acid (20 kDa) on acrylated poly(2-hydroxyethyl methacrylate) via nucleophile-initiated Michael addition thiol-ene "click" chemistry. The surface chemistry of the modified surfaces was analyzed by Fourier transform infrared spectroscopy-attenuated total reflectance and X-ray photoelectron spectroscopy. The appearance of N (1s) and S (2p) peaks on the low resolution X-ray photoelectron spectroscopy spectra confirmed successful immobilization of hyaluronic acid. Grafting hyaluronic acid to the poly(2-hydroxyethyl methacrylate) surfaces decreased the contact angle, the dehydration rate, and the amount of nonspecific sorption of lysozyme and albumin in comparison to pristine hydrogel materials, suggesting the development of more wettable surfaces with improved water-retentive and antifouling properties, while maintaining optical transparency (>92%). In vitro testing also showed excellent viability of human corneal epithelial cells with the hyaluronic acid-grafted poly(2-hydroxyethyl methacrylate) surfaces. Hence, surface modification with hyaluronic acid via thiol-ene "click" chemistry could be useful in improving contact lens surface properties, potentially alleviating symptoms of contact lens related dryness and discomfort during wear.
Collapse
Affiliation(s)
- Myrto Korogiannaki
- 1 Department of Chemical Engineering, McMaster University, Hamilton, ON, Canada
| | - Jianfeng Zhang
- 2 264790 Saint-Gobain Northborough Research and Development Center , Northboro, MA, USA
| | - Heather Sheardown
- 1 Department of Chemical Engineering, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
8
|
Efficacy of Contact Lens Care Solutions in Removing Cholesterol Deposits From Silicone Hydrogel Contact Lenses. Eye Contact Lens 2018; 45:105-111. [PMID: 30199424 DOI: 10.1097/icl.0000000000000547] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine the efficacy of multipurpose solutions (MPSs) on the removal of cholesterol deposits from silicone hydrogel (SH) contact lens materials using an in vitro model. MATERIALS AND METHODS Five SH lens materials: senofilcon A, comfilcon A, balafilcon A, lotrafilcon A, and lotrafilcon B were removed from the blister pack (n=4 for each lens type), incubated for 7 days at 37°C in an artificial tear solution containing C radiolabeled cholesterol. Thereafter, lenses were stored in a preserved saline solution control (Sensitive Eyes Saline Plus) or cleaned with 1 of the 5 MPSs incorporating different preservatives (POLYQUAD/ALDOX, polyquaternium-1/alexidine, polyquaternium-1/PHMB, and 2 based on PHMB alone) using a rub and rinse technique, according to the manufacturer's recommendations, and stored in the MPS for a minimum of 6 hr. Lenses were then extracted with 2:1 chloroform:methanol, analyzed in a beta counter, and μg/lens of cholesterol was determined. RESULTS Balafilcon A and senofilcon A lens materials showed the highest amounts of accumulated cholesterol (0.93±0.02 μg/lens; 0.95±0.01 μg/lens, respectively), whereas lotrafilcon A and lotrafilcon B deposited the lowest amounts (0.37±0.03 μg/lens; 0.47±0.12 μg/lens, respectively). For all lens materials, the MPS preserved with POLYQUAD/ALDOX removed more deposited cholesterol than any other test solution; however, the amount of removed cholesterol contamination from the individual contact lenses was only statistically significant for balafilcon A and senofilcon A (P=0.006 and P=0.042, respectively). Sensitive eyes and the other evaluated MPSs showed no significant effect on cholesterol removal (P>0.05). CONCLUSION Cholesterol-removal efficacy varies depending on the combination of lens material and solution. Only 1 MPS showed a statistically significant reduction of cholesterol deposit for only 2 of the 5 tested lens materials.
Collapse
|
9
|
In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials. Optom Vis Sci 2017; 94:1047-1051. [PMID: 29040199 DOI: 10.1097/opx.0000000000001137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. PURPOSE This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. METHODS Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme-coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing I-labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate-buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. RESULTS Results are reported as mean ± SD. Lysozyme-coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P < .05). There were no differences in albumin adsorption between control (uncoated) and lysozyme-coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials (P > .05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses (P < .05). CONCLUSIONS This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.
Collapse
|
10
|
Zhang W, Li G, Lin Y, Wang L, Wu S. Preparation and characterization of protein-resistant hydrogels for soft contact lens applications via radical copolymerization involving a zwitterionic sulfobetaine comonomer. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2017; 28:1935-1949. [DOI: 10.1080/09205063.2017.1363127] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Wanlu Zhang
- School of Materials Science and Engineering, South China University of Technology, Guangzhou, China
| | - Guangji Li
- School of Materials Science and Engineering, South China University of Technology, Guangzhou, China
| | - Yinlei Lin
- School of Materials Science and Engineering, South China University of Technology, Guangzhou, China
| | - Liying Wang
- School of Materials Science and Engineering, South China University of Technology, Guangzhou, China
| | - Shuqing Wu
- School of Materials Science and Engineering, South China University of Technology, Guangzhou, China
| |
Collapse
|
11
|
Guzman G, Bhaway SM, Nugay T, Vogt BD, Cakmak M. Transport-Limited Adsorption of Plasma Proteins on Bimodal Amphiphilic Polymer Co-Networks: Real-Time Studies by Spectroscopic Ellipsometry. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2017; 33:2900-2910. [PMID: 28240027 DOI: 10.1021/acs.langmuir.7b00281] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Traditional hydrogels are commonly limited by poor mechanical properties and low oxygen permeability. Bimodal amphiphilic co-networks (β-APCNs) are a new class of materials that can overcome these limitations by combining hydrophilic and hydrophobic polymer chains within a network of co-continuous morphology. Applications that can benefit from these improved properties include therapeutic contact lenses, enzymatic catalysis supports, and immunoisolation membranes. The continuous hydrophobic phase could potentially increase the adsorption of plasma proteins in blood-contacting medical applications and compromise in vivo material performance, so it is critical to understand the surface characteristics of β-APCNs and adsorption of plasma proteins on β-APCNs. From real-time spectroscopic visible (Vis) ellipsometry measurements, plasma protein adsorption on β-APCNs is shown to be transport-limited. The adsorption of proteins on the β-APCNs is a multistep process with adsorption to the hydrophilic surface initially, followed by diffusion into the material to the internal hydrophilic/hydrophobic interfaces. Increasing the cross-linking of the PDMS phase reduced the protein intake by limiting the transport of large proteins. Moreover, the internalization of the proteins is confirmed by the difference between the surface-adsorbed protein layer determined from XPS and bulk thickness change from Vis ellipsometry, which can differ up to 20-fold. Desorption kinetics depend on the adsorption history with rapid desorption for slow adsorption rates (i.e., slow-diffusing proteins within the network), whereas proteins with fast adsorption kinetics do not readily desorb. This behavior can be directly related to the ability of the protein to spread or reorient, which affects the binding energy required to bind to the internal hydrophobic interfaces.
Collapse
Affiliation(s)
- Gustavo Guzman
- Polymer Engineering Department, The University of Akron , Akron, Ohio 44325, United States
| | - Sarang M Bhaway
- Polymer Engineering Department, The University of Akron , Akron, Ohio 44325, United States
| | - Turgut Nugay
- Chemistry Department, Polymer Research Center, Boğaziçi University , Bebek, 34342 Istanbul, Turkey
| | - Bryan D Vogt
- Polymer Engineering Department, The University of Akron , Akron, Ohio 44325, United States
| | - Mukerrem Cakmak
- Polymer Engineering Department, The University of Akron , Akron, Ohio 44325, United States
| |
Collapse
|
12
|
Deng X, Korogiannaki M, Rastegari B, Zhang J, Chen M, Fu Q, Sheardown H, Filipe CDM, Hoare T. "Click" Chemistry-Tethered Hyaluronic Acid-Based Contact Lens Coatings Improve Lens Wettability and Lower Protein Adsorption. ACS APPLIED MATERIALS & INTERFACES 2016; 8:22064-22073. [PMID: 27509015 DOI: 10.1021/acsami.6b07433] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Improving the wettability of and reducing the protein adsorption to contact lenses may be beneficial for improving wearer comfort. Herein, we describe a simple "click" chemistry approach to surface functionalize poly(2-hydroxyethyl methacrylate) (pHEMA)-based contact lenses with hyaluronic acid (HA), a carbohydrate naturally contributing to the wettability of the native tear film. A two-step preparation technique consisting of laccase/TEMPO-mediated oxidation followed by covalent grafting of hydrazide-functionalized HA via simple immersion resulted in a model lens surface that is significantly more wettable, more water retentive, and less protein binding than unmodified pHEMA while maintaining the favorable transparency, refractive, and mechanical properties of a native lens. The dipping/coating method we developed to covalently tether the HA wetting agent is simple, readily scalable, and a highly efficient route for contact lens modification.
Collapse
Affiliation(s)
- Xudong Deng
- Department of Chemical Engineering, McMaster University , Hamilton, Ontario L8S 4L7, Canada
| | - Myrto Korogiannaki
- Department of Chemical Engineering, McMaster University , Hamilton, Ontario L8S 4L7, Canada
| | - Banafsheh Rastegari
- Department of Chemical Engineering, McMaster University , Hamilton, Ontario L8S 4L7, Canada
- Department of Biology, Faculty of Sciences, Shiraz University , Shiraz, Fars 71946-84636, Iran
| | - Jianfeng Zhang
- Department of Chemical Engineering, McMaster University , Hamilton, Ontario L8S 4L7, Canada
| | - Mengsu Chen
- School of Nursing, McMaster University , Hamilton, Ontario L8S 4L8, Canada
| | - Qiang Fu
- Department of Chemical Engineering, McMaster University , Hamilton, Ontario L8S 4L7, Canada
| | - Heather Sheardown
- Department of Chemical Engineering, McMaster University , Hamilton, Ontario L8S 4L7, Canada
| | - Carlos D M Filipe
- Department of Chemical Engineering, McMaster University , Hamilton, Ontario L8S 4L7, Canada
| | - Todd Hoare
- Department of Chemical Engineering, McMaster University , Hamilton, Ontario L8S 4L7, Canada
| |
Collapse
|
13
|
Xu C, He R, Xie B, Ismail M, Yao C, Luan J, Li X. Silicone hydrogels grafted with natural amino acids for ophthalmological application. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2016; 27:1354-68. [DOI: 10.1080/09205063.2016.1201916] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- Chen Xu
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Ruiyu He
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Binbin Xie
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Muhammad Ismail
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Chen Yao
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Jie Luan
- Department of Ophthalmology, Zhongda Hospital Southeast University, Nanjing, China
| | - Xinsong Li
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| |
Collapse
|
14
|
Nanoscale Plasma Coating Inhibits Formation of Staphylococcus aureus Biofilm. Antimicrob Agents Chemother 2015; 59:7308-15. [PMID: 26369955 DOI: 10.1128/aac.01944-15] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2015] [Accepted: 09/06/2015] [Indexed: 11/20/2022] Open
Abstract
Staphylococcus aureus commonly infects medical implants or devices, with devastating consequences for the patient. The infection begins with bacterial attachment to the device, followed by bacterial multiplication over the surface of the device, generating an adherent sheet of bacteria known as a biofilm. Biofilms resist antimicrobial therapy and promote persistent infection, making management difficult to futile. Infections might be prevented by engineering the surface of the device to discourage bacterial attachment and multiplication; however, progress in this area has been limited. We have developed a novel nanoscale plasma coating technology to inhibit the formation of Staphylococcus aureus biofilms. We used monomeric trimethylsilane (TMS) and oxygen to coat the surfaces of silicone rubber, a material often used in the fabrication of implantable medical devices. By quantitative and qualitative analysis, the TMS/O2 coating significantly decreased the in vitro formation of S. aureus biofilms; it also significantly decreased in vivo biofilm formation in a mouse model of foreign-body infection. Further analysis demonstrated TMS/O2 coating significantly changed the protein adsorption, which could lead to reduced bacterial adhesion and biofilm formation. These results suggest that TMS/O2 coating can be used to effectively prevent medical implant-related infections.
Collapse
|
15
|
Chan KY, Cho P, Boost M. Microbial adherence to cosmetic contact lenses. Cont Lens Anterior Eye 2014; 37:267-72. [PMID: 24440107 DOI: 10.1016/j.clae.2013.12.002] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2013] [Revised: 10/17/2013] [Accepted: 12/05/2013] [Indexed: 10/25/2022]
Abstract
AIM To investigate whether cosmetic contact lenses (CCL) with surface pigments affect microbial adherence. METHOD Fifteen brands of CCL were purchased from optical, non-optical retail outlets, and via the Internet. A standardized rub-off test was performed on each CCL (five lenses per brand) to confirm the location of the pigments. The rub-off test comprised gentle rubbing on the surfaces of each CCL with wetted cotton buds for a maximum of 20 rubs per surface. A new set of CCL (five lenses per brand) were incubated in Pseudomonas aeruginosa overnight. Viable counts of adhered bacteria were determined by the number of colony-forming units (CFU) on agar media on each lens. The adherence of P. aeruginosa as well as Staphylococcus aureus and Serratia marcescens to three brands of CCL (A-C) (five lenses per brand) were also compared to their adherences on their clear counterparts. RESULTS Only two of the 15 brands of CCL tested (brands B and C) had pigments that did not detach with the rub-off test. The remaining 13 brands of CCL all failed the rub-off test and these lenses showed higher P. aeruginosa adherence (8.7 × 10(5)-1.9 × 10(6) CFU/lens). Brands B and C lenses showed at least six times less bacterial adhesion than the other 13 brands. Compared to their clear counterparts, bacterial adherence to brands B and C lenses did not differ significantly, whereas brand A lenses showed significantly higher adherence. CONCLUSION Surface pigments on CCL resulted in significantly higher bacterial adherence.
Collapse
Affiliation(s)
- Ka Yin Chan
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region.
| | - Pauline Cho
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region
| | - Maureen Boost
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region
| |
Collapse
|
16
|
Abstract
PURPOSE Microbial adhesion to contact lenses is believed to be one of the initiating events in the formation of many corneal infiltrative events, including microbial keratitis, that occur during contact lens wear. The advent of silicone hydrogel lenses has not reduced the incidence of these events. This may partly be related to the ability of microbes to adhere to these lenses. The aim of this study was to review the published literature on microbial adhesion to contact lenses, focusing on adhesion to silicone hydrogel lenses. METHODS The literature on microbial adhesion to contact lenses was searched, along with associated literature on adverse events that occur during contact lens wear. Particular reference was paid to the years 1995 through 2012 because this encompasses the time when the first clinical trials of silicone hydrogel lenses were reported, and their commercial availability and the publication of epidemiology studies on adverse events were studied. RESULTS In vitro studies of bacterial adhesion to unworn silicone hydrogel lens have shown that generally, bacteria adhere to these lenses in greater numbers than to the hydroxyethyl methacrylate-based soft lenses. Lens wear has different effects on microbial adhesion, and this is dependent on the type of lens and microbial species/genera that is studied. Biofilms that can be formed on any lens type tend to protect the bacteria and fungi from the effects on disinfectants. Fungal hyphae can penetrate the surface of most types of lenses. Acanthamoeba adhere in greater numbers to first-generation silicone hydrogel lenses compared with the second-generation or hydroxyethyl methacrylate-based soft lenses. CONCLUSION Microbial adhesion to silicone hydrogel lenses occurs and is associated with the production of corneal infiltrative events during lens wear.
Collapse
|
17
|
|
18
|
Subbaraman LN, Jones L. Kinetics of Lysozyme Activity Recovered from Conventional and Silicone Hydrogel Contact Lens Materials. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 21:343-58. [DOI: 10.1163/156856209x415873] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Lakshman N. Subbaraman
- a Centre for Contact Lens Research, School of Optometry, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Lyndon Jones
- b Centre for Contact Lens Research, School of Optometry, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
19
|
Protein deposition on contact lenses: The past, the present, and the future. Cont Lens Anterior Eye 2012; 35:53-64. [DOI: 10.1016/j.clae.2011.12.005] [Citation(s) in RCA: 119] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2010] [Revised: 12/18/2011] [Accepted: 12/24/2011] [Indexed: 11/19/2022]
|
20
|
Abstract
PURPOSE To quantify non-polar lipids deposited on senofilcon A silicone hydrogel contact lenses (J&J Acuvue OASYS) when disinfected with a no-rub one-step hydrogen peroxide system (CIBA Vision ClearCare) and a care system preserved with Polyquad & Aldox (Alcon OPTI-FREE RepleniSH). METHODS Thirty existing soft lens wearers symptomatic of dryness were enrolled into a 4-week prospective, randomized, bilateral eye (lens type), cross-over (care regimen), daily wear, double masked study. Subjects were refitted with senofilcon A lenses, which were replaced biweekly. During each period of wear, participants used either the peroxide or preserved system. After each period of wear, lenses were collected and lipid was extracted using 1.5 ml of a 2:1 chloroform:methanol solution for 3 h at 37 °C. Lens extracts were analyzed for non-polar lipids [cholesterol oleate (CO), cholesterol, oleic acid (OA), triolein, and OA methyl ester] using normal phase high-performance liquid chromatography. RESULTS The total lipid (sum of CO and cholesterol) detected was 34 ± 28 μg/lens for the peroxide-based system and 22 ± 21 μg/lens for the system preserved with Polyquad and Aldox (p = 0.029). Although there was no difference between products for cholesterol (1.4 vs. 1.3 μg/lens; p = 0.50), use of a system preserved with Polyquad and Aldox resulted in significantly less deposited CO (33 ± 28 vs. 21 ± 20 μg/lens; p = 0.033). Approximately, 95% of the detectable lipid deposited on the material was CO, followed by cholesterol. OA and triolein contributed <1% of the total lipid and no OA methyl ester was found on any of the lenses. CONCLUSIONS A care system preserved with Polyquad and Aldox removed higher amounts of CO from senofilcon A contact lenses used for 2 weeks than a peroxide-based system, in soft lens wearers who were symptomatic of dry eye.
Collapse
|
21
|
|
22
|
|
23
|
|
24
|
|
25
|
|
26
|
Dynamics of flagellum- and pilus-mediated association of Pseudomonas aeruginosa with contact lens surfaces. Appl Environ Microbiol 2011; 77:3644-52. [PMID: 21498762 DOI: 10.1128/aem.02656-10] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Flagella and pili are appendages that modulate attachment of Pseudomonas aeruginosa to solid surfaces. However, previous studies have mostly reported absolute attachment. Neither the dynamic roles of these appendages in surface association nor those of attachment phenotypes have been quantified. We used video microscopy to address this issue. Unworn, sterile, soft contact lenses were placed in a laminar-flow optical chamber. Initial lens association kinetics for P. aeruginosa strain PAK were assessed in addition to lens-surface association phenotypes. Comparisons were made to strains with mutations in flagellin (fliC) or pilin (pilA) or those in flagellum (motAB) or pilus (pilU) function. PAK and its mutants associated with the contact lens surface at a constant rate according to first-order kinetics. Nonswimming mutants associated ∼30 to 40 times slower than the wild type. PAK and its pilA mutant associated at similar rates, but each ∼4 times faster than the pilU mutant. Lens attachment by wild-type PAK induced multiple phenotypes (static, lateral, and rotational surface movement), each showing only minor detachment. Flagellin (fliC) and flagellar-motility (motAB) mutants did not exhibit surface rotation. Conversely, strains with mutations in pilin (pilA) and pilus retraction (pilU) lacked lateral-surface movement but displayed enhanced surface rotation. Slower surface association of swimming-incapable P. aeruginosa mutants was ascribed to lower convective-diffusion-arrival rates, not to an inability to adhere. Flagellum function (swimming) enhanced lens association, attachment, and rotation; hyperpiliation hindered lens association. P. aeruginosa bound through three different adhesion sites: flagellum, pili, and body. Reduction of bacterial attachment to contact lenses thus requires blockage of multiple adhesion phenotypes.
Collapse
|
27
|
Yañez F, Gomez-Amoza JL, Magariños B, Concheiro A, Alvarez-Lorenzo C. Hydrogels porosity and bacteria penetration: Where is the pore size threshold? J Memb Sci 2010. [DOI: 10.1016/j.memsci.2010.09.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
28
|
Rändler C, Matthes R, McBain AJ, Giese B, Fraunholz M, Sietmann R, Kohlmann T, Hübner NO, Kramer A. A three-phase in-vitro system for studying Pseudomonas aeruginosa adhesion and biofilm formation upon hydrogel contact lenses. BMC Microbiol 2010; 10:282. [PMID: 21062489 PMCID: PMC2997771 DOI: 10.1186/1471-2180-10-282] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2009] [Accepted: 11/09/2010] [Indexed: 11/24/2022] Open
Abstract
Background Pseudomonas aeruginosa is commonly associated with contact lens (CL) -related eye infections, for which bacterial adhesion and biofilm formation upon hydrogel CLs is a specific risk factor. Whilst P. aeruginosa has been widely used as a model organism for initial biofilm formation on CLs, in-vitro models that closely reproduce in-vivo conditions have rarely been presented. Results In the current investigation, a novel in-vitro biofilm model for studying the adherence of P. aeruginosa to hydrogel CLs was established. Nutritional and interfacial conditions similar to those in the eye of a CL wearer were created through the involvement of a solid:liquid and a solid:air interface, shear forces and a complex artificial tear fluid. Bioburdens varied depending on the CL material and biofilm maturation occurred after 72 h incubation. Whilst a range of biofilm morphologies were visualised including dispersed and adherent bacterial cells, aggregates and colonies embedded in extracellular polymer substances (EPS), EPS fibres, mushroom-like formations, and crystalline structures, a compact and heterogeneous biofilm morphology predominated on all CL materials. Conclusions In order to better understand the process of biofilm formation on CLs and to test the efficacy of CL care solutions, representative in-vitro biofilm models are required. Here, we present a three-phase biofilm model that simulates the environment in the eye of a CL wearer and thus generates biofilms which resemble those commonly observed in-situ.
Collapse
Affiliation(s)
- Claudia Rändler
- Department of Hygiene and Environmental Medicine, Ernst Moritz Arndt University Greifswald, Greifswald, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Luensmann D, Heynen M, Liu L, Sheardown H, Jones L. Determination of albumin sorption to intraocular lenses by radiolabeling and confocal laser scanning microscopy. J Cataract Refract Surg 2010; 35:2000-7. [PMID: 19878835 DOI: 10.1016/j.jcrs.2009.05.052] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2009] [Revised: 05/22/2009] [Accepted: 05/26/2009] [Indexed: 11/24/2022]
Abstract
PURPOSE To determine albumin adsorption profiles and penetration depth of 3 intraocular lens (IOL) materials over time using confocal laser scanning microscopy (CLSM) and radiolabeling. SETTING Centre for Contact Lens Research, School of Optometry, and Department of Biology, University of Waterloo, Waterloo, Ontario, Canada. METHODS Poly(methyl methacrylate) (PMMA), silicone, and foldable hydrophilic acrylic IOLs were incubated in 0.5 mg/mL bovine serum albumin (BSA) for 1, 7, and 14 days. The BSA was conjugated with lucifer yellow VS to allow identification of the protein location by fluorescent imaging with CLSM. Next, the protein uptake was quantified using 2% (125)I-labeled BSA. RESULTS Confocal laser scanning microscopy showed increasing BSA uptake for silicone and PMMA IOLs after 14 days of incubation (P<.05), with an apparent penetration depth of 8.7 microm +/- 1.9 (SD) and 9.2 +/- 1.4 microm, respectively. For hydrophilic acrylic IOLs, BSA was detected at a depth of 38 +/- 7.4 microm after 1 day, followed by an increase to 192.7 +/- 16.2 microm after 14 days. Despite the penetration depth into the hydrophilic acrylic IOLs, quantitative results confirmed that PMMA and hydrophilic acrylic deposited significantly less BSA (mean 278.3 +/- 41.7 ng and 296.5 +/- 33.1 ng, respectively) than silicone IOLs (mean 392.6 +/- 37.6 ng) (P<.05). CONCLUSIONS Silicone and PMMA IOL materials showed BSA sorption near the lens surface only, while BSA penetrated deep into the hydrophilic acrylic IOL matrix. Combining the qualitative CLSM method and quantitative radiolabeling technique provided detailed information on protein interactions with implantable biomaterials.
Collapse
Affiliation(s)
- Doerte Luensmann
- Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada.
| | | | | | | | | |
Collapse
|
30
|
Abstract
PURPOSE To determine the impact of the rinse step in "no rub" contact lens care systems relative to its ability to assist in removing loosely associated and bound tear film proteins from a worn silicone hydrogel lens. METHODS After informed consent, subjects were fitted with lotrafilcon B contact lenses (CIBA Vision). If the fit was acceptable, subjects were asked to wear the lenses on a daily wear basis for 5 (+2, -0) days for an outcome visit. Subjects were instructed to use AQuify Multi-Purpose Disinfecting Solution (CIBA Vision) following the manufacturer's "no rub" instructions. At the outcome visit, contact lenses were then collected by a gloved examiner, with a sterile metal forceps, who rinsed the right lens but did not rinse the left lens on removal from the eyes. Protein was extracted with a 50:50 0.2% trifluoroacetic acid-acetonitrile solution and quantified using a Bradford analyses. RESULTS Twenty contact lens wearers were enrolled in this study. For the non-rinsed lenses, the first extraction yielded 13.4 +/- 9.2 microg/lens of protein, whereas the second extraction yielded 5.8 +/- 2.8 microg/lens of protein. For the rinsed lenses, the first extraction yielded an average of 3.0 +/- 1.9 microg/lens of protein, whereas the second extraction yielded an average of 4.0 +/- 2.3 microg/lens. Repeated measures analysis of variance showed a significant interaction (F-statistic = 18.9, p < 0.0001) between the rinse of a lens and extraction number. CONCLUSIONS Rinsing a contact lens after removal from the eye removes well more than one-half of the protein associated with it. Further, to biochemically recover all protein from a silicone hydrogel lens, it may be important to perform more than one chemical extraction from it.
Collapse
|
31
|
In Vitro Adsorption of Tear Proteins to Hydroxyethyl Methacrylate-Based Contact Lens Materials. Eye Contact Lens 2009; 35:320-8. [DOI: 10.1097/icl.0b013e3181becd3c] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
32
|
Efficacy of an Extraction Solvent Used to Quantify Albumin Deposition on Hydrogel Contact Lens Materials. Eye Contact Lens 2009; 35:76-80. [DOI: 10.1097/icl.0b013e318199aff6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
33
|
|
34
|
Quartz crystal microbalance study of protein adsorption kinetics on poly(2-hydroxyethyl methacrylate). J Colloid Interface Sci 2008; 325:157-64. [DOI: 10.1016/j.jcis.2008.05.052] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2008] [Revised: 04/18/2008] [Accepted: 05/28/2008] [Indexed: 11/19/2022]
|
35
|
Albumin adsorption to contact lens materials: A review. Cont Lens Anterior Eye 2008; 31:179-87. [DOI: 10.1016/j.clae.2008.05.004] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2007] [Revised: 05/12/2008] [Accepted: 05/15/2008] [Indexed: 11/21/2022]
|
36
|
Luensmann D, Glasier MA, Zhang F, Bantseev V, Simpson T, Jones L. Confocal Microscopy and Albumin Penetration into Contact Lenses. Optom Vis Sci 2007; 84:839-47. [PMID: 17873769 DOI: 10.1097/opx.0b013e3181559ea4] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To develop a novel in vitro method to detect the depth of penetration of the tear film protein albumin into contact lens materials using confocal laser scanning microscopy (CLSM). METHODS A poly-HEMA-based hydrogel (etafilcon A) and a silicone hydrogel material (lotrafilcon B) were examined. In vitro, bovine serum albumin (BSA) was labeled with 5-(4,6-dichloro-s-triazin-2-ylamino) fluorescein hydrochloride (DTAF). The lenses were incubated in this protein solution (0.5 mg/ml) at 37 degrees C. After 1 and 7 days incubation, the lenses were examined using CLSM (Zeiss 510, config. META 18) and the location of the fluorescently labeled BSA was identified. RESULTS BSA adsorption on the surface and penetration into the lens matrix occurred at a higher concentration for etafilcon compared to lotrafilcon (p < 0.001). For both materials, BSA was detected on the surface after 1 day of incubation. Significant levels of BSA were detected within the matrix of etafilcon after as little as 1 day (p < 0.001), but no BSA was detected in the matrix of lotrafilcon at any time (p > 0.05). CONCLUSION CLSM can be successfully used to examine the depth of penetration of fluorescently labeled proteins into various hydrogel polymers. Our results show that etafilcon lenses both adsorb BSA on the surface and absorb BSA within the matrix, whereas lotrafilcon B adsorbs small amounts of BSA on the surface only.
Collapse
Affiliation(s)
- Doerte Luensmann
- Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada.
| | | | | | | | | | | |
Collapse
|
37
|
Abstract
PURPOSE To establish proper contact lens care as a common practice by discovering the quantity and condition of protein deposition on various types of soft contact lenses. METHODS The amounts of deposition of two proteins found in tear fluid, lysozyme and albumin, on various types of contact lenses were measured. Lenses deposited with albumin and lenses deposited with lysozyme were stained with Coomassie brilliant blue (CBB). Frozen cross-sections of these lenses were examined using a microscope. RESULTS A considerably larger amount of lysozyme was found on group IV (U.S. Food and Drug Administration classification) contact lenses. Conversely, there were no significant differences between the four groups in the quantity of albumin found. When various lenses were stained with CBB, only the lysozyme-deposited lenses of group IV obtained a strong tint. When cross-sections of the tinted group IV contact lenses were examined, not only the surface, but also the matrix of the lens was stained. CONCLUSIONS Results suggested that the reason group IV lenses accumulated a considerably greater amount of lysozyme than did lenses of other groups is that lysozyme accumulates not only on the surface, but also in the matrix of group IV lenses.
Collapse
Affiliation(s)
- Eiichi Okada
- Okada Eye Clinic, Yokohama City University School of Medicine, Yokohama, Japan.
| | | | | | | |
Collapse
|
38
|
Borazjani RN, Levy B, Ahearn DG. Relative primary adhesion of Pseudomonas aeruginosa, Serratia marcescens and Staphylococcus aureus to HEMA-type contact lenses and an extended wear silicone hydrogel contact lens of high oxygen permeability. Cont Lens Anterior Eye 2004; 27:3-8. [PMID: 16303520 DOI: 10.1016/j.clae.2003.08.001] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To compare multiple strains of Pseudomonas aeruginosa and representative isolates of Staphylococcus aureus and Serratia marcescens for their relative primary adhesion to a high Dk silicone hydrogel lens (36% H2O) with that of a HEMA-type lens (58% H2O). METHODS A radiolabeled cell procedure with a 2-h cell exposure was employed for enumerating bacteria on unworn and worn silicone hydrogel (balafilcon A) and HEMA-type (etafilcon A) hydrogel lenses. RESULTS The degree of primary adhesion of P. aeruginosa to 7-day worn balafilcon A lens was similar to the degree of adhesion to unworn balafilcon A lenses. The degree of primary adhesion by clinical strains to unworn balafilcon A lenses and etafilcon lenses was strain variable, but did not differ markedly for the two lenses with a given strain of P. aeruginosa. Relative to most of the pseudomonad strains, adhesion to the hydrogel lenses by S. aureus and S. marcescens was non-significant. CONCLUSION Adhesion of strains of P. aeruginosa to a hydrogel contact lens does not appear to differ appreciably between the HEMA-type etafilcon A and the high Dk silicone hydrogel balafilcon A lens.
Collapse
Affiliation(s)
- Roya N Borazjani
- Bausch & Lomb, 1400 N. Goodman St., RD&E, P.O. Box 0450, Rochester, NY 14603, USA
| | | | | |
Collapse
|
39
|
Pearce D, Tan ME, Demirci G, Willcox MDP. Surface protein profile of extended-wear silicon hydrogel lenses. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2003; 506:957-60. [PMID: 12614017 DOI: 10.1007/978-1-4615-0717-8_135] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
Affiliation(s)
- Damon Pearce
- Cooperative Research Centre for Eye Research and Technology, University of New South Wales, Sydney, Australia
| | | | | | | |
Collapse
|
40
|
Kim SH, Opdahl A, Marmo C, Somorjai GA. AFM and SFG studies of pHEMA-based hydrogel contact lens surfaces in saline solution: adhesion, friction, and the presence of non-crosslinked polymer chains at the surface. Biomaterials 2002; 23:1657-66. [PMID: 11922469 DOI: 10.1016/s0142-9612(01)00292-7] [Citation(s) in RCA: 121] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The surfaces of two types of soft contact lenses neutral and ionic hydrogels--were characterized by atomic force microscopy (AFM) and sum-frequency-generation (SFG) vibrational spectroscopy. AFM measurements in saline solution showed that the presence of ionic functional groups at the surface lowered the friction and adhesion to a hydrophobic polystyrene tip. This was attributed to the specific interactions of water and the molecular orientation of hydrogel chains at the surface. Friction and adhesion behavior also revealed the presence of domains of non-crosslinked polymer chains at the lens surface. SFG showed that the lens surface became partially dehydrated upon exposure to air. On this partially dehydrated lens surface, the non-crosslinked domains exhibited low friction and adhesion in AFM. Fully hydrated in saline solution, the non-crosslinked domains extended more than tens of nanometers into solution and were mobile.
Collapse
Affiliation(s)
- Seong Han Kim
- Department of Chemistry, University of California at Berkley, 94720, USA
| | | | | | | |
Collapse
|
41
|
Kim SH, Marmo C, Somorjai GA. Friction studies of hydrogel contact lenses using AFM: non-crosslinked polymers of low friction at the surface. Biomaterials 2001; 22:3285-94. [PMID: 11700800 DOI: 10.1016/s0142-9612(01)00175-2] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The surface of soft contact lenses made of crosslinked poly(2-hydroxyethyl methacrylate). pHEMA, has been investigated with atomic force microscopy in contact mode. The friction force and adhesive force measurements were able to differentiate the non-crosslinked pHEMA chains from the surface of the crosslinked pHEMA networks. These non-crosslinked pHEMA chains at the surface were anchored to the crosslinked pHEMA network, most likely by entanglement and their surfaces were about 2-4nm higher than the surrounding surface in a dehydrated state. In saline solution, the surface friction and adhesive force of the contact lens were significantly reduced compared to those measured for the surface-dehydrated contact lens.
Collapse
Affiliation(s)
- S H Kim
- Department of Chemistry University of California at Berkeley, 94720, USA
| | | | | |
Collapse
|
42
|
Andrews CS, Denyer SP, Hall B, Hanlon GW, Lloyd AW. A comparison of the use of an ATP-based bioluminescent assay and image analysis for the assessment of bacterial adhesion to standard HEMA and biomimetic soft contact lenses. Biomaterials 2001; 22:3225-33. [PMID: 11700794 DOI: 10.1016/s0142-9612(01)00160-0] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The aim of this study was to investigate in vitro adhesion of clinically relevant bacteria to standard HEMA and novel biomimetic soft contact lenses (SCL) using bioluminescent ATP assay and image analysis. Unworn SCL were incubated with Pseudomonas aeruginosa, Staphylococcus epidermidis or Serratia marcescens suspended in sterile phosphate buffered saline (PBS). The level of bacterial adhesion after 1, 2, 4, 6 and 18h, was assessed using both image analysis and a bioluminescent ATP assay. Species differences in the overall level of adhesion to the different types of lens were observed using both measurement techniques. Generally bacterial adhesion was shown to peak at 4-6 h, then decline to a much lower level by 18 h. After 4 h, adhesion of all species of bacteria to the biomimetic SCL (omafilcon A) was found to be significantly lower than to the standard HEMA SCL (polymacon) (p<0.05. Student's t-test, n = 4). Both these techniques demonstrated that novel biomimetic SCL materials exhibit significantly lower bacterial adhesion in vitro compared to standard HEMA SCL materials. SCL manufactured with these novel biomimetic materials may reduce the risk of infection.
Collapse
Affiliation(s)
- C S Andrews
- Biomedical Materials Research Group, School of Pharmacy and Biomolecular Sciences, University of Brighton Moulsecoomb, UK
| | | | | | | | | |
Collapse
|
43
|
Willcox MD, Harmis N, Williams T. Bacterial interactions with contact lenses; effects of lens material, lens wear and microbial physiology. Biomaterials 2001; 22:3235-47. [PMID: 11700795 DOI: 10.1016/s0142-9612(01)00161-2] [Citation(s) in RCA: 134] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Contact lens wear is a successful form of vision correction. However, adverse responses can occur during wear. Many of these adverse responses are produced as a consequence of bacterial colonization of the lens. The present study demonstrated that during asymptomatic contact lens wear lenses are colonized by low levels of bacteria with gram-positive bacteria, such as coagulase negative staphylococci, predominating. Gram-negative bacteria are frequently the causative agents of adverse responses during contact lens wear. Measuring the adhesion of different strains and/or species of bacteria to different contact lens materials demonstrated considerable differences. In particular. Pseudormonas aeruginosa strains Paerl and 6294 and Aeromonas hydrophilia strain Ahyd003 adhered in larger numbers to the highly oxygen permeable contact lenses Balafilcon A compared to hydrogel lenses manufactured from either Etafilcon A or HEMA. Furthermore, after Balafilcon A lenses had been worn for 6 h during the day bacteria were able to adhere in greater numbers to the worn lenses compared to the unworn lenses with increases in adhesion ranging from 243% to 1393%. However, wearing Etafilcon A lenses usually resulted in a decrease in adhesion (22-48%). Bacteria were able to grow after adhesion to lenses soaked in artificial tear fluid and formed biofilms, visualized by scanning confocal microscopy. Chemostat grown bacterial cultures were utilized to enable control of bacterial growth conditions and bacteria were shown to adhere in the greatest numbers if grown under low temperature (25 degrees C compared to 37 degrees C). The changes in growth temperature was shown. using 2D gel electrophoresis, to change the experssion of cell-surface proteins and, using ID gel electrophoresis, to change the expression of surface lipopolysaccharide of P. aeruginosa Paerl. Thus, these surface changes would have been likely to have mediated the increased adhesion to Etafilcon A contact lenses.
Collapse
Affiliation(s)
- M D Willcox
- Co-operatiue Research Centre for Eye Research and Technology, University of New South Wales, Sydney, Australia.
| | | | | |
Collapse
|
44
|
Abstract
The maintenance of vision is a key determinant of healthy ageing. This has been facilitated over recent decades by the development of a wide range of implants and biomedical devices to correct the functional deficiencies of disease, age and ocular trauma. This brief overview provides an insight into the structure of this unique organ, the major physiological functions of the component tissues and the present state of the art with respect to modern ocular implants. The review focuses primarily on the existing limitations of existing ocular biomaterials used in the fabrication of contact lenses, intraocular lenses, glaucoma filtration implants, keratoprostheses, intracorneal implants, scleral buckles and viscoelastic replacement agents. The challenge of improving ocular compatibility and ensuring the longevity of indwelling ocular devices is addressed along with the need to improve the physicochemical and mechanical properties of existing ocular biomaterials.
Collapse
Affiliation(s)
- A W Lloyd
- Biomedical Materials Research Group, School of Pharmacy & Biomolecular Sciences, University of Brighton, UK.
| | | | | |
Collapse
|