1
|
Heiliger C, Piecuch J, Frank A, Andrade D, von Ehrlich-Treuenstätt V, Evtimova D, Kühn F, Werner J, Karcz K. Laparoscopic intraarterial catheterization with selective ICG fluorescence imaging in colorectal surgery. Sci Rep 2021; 11:14753. [PMID: 34285284 PMCID: PMC8292501 DOI: 10.1038/s41598-021-94244-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Accepted: 07/07/2021] [Indexed: 11/29/2022] Open
Abstract
The quality of mesorectal resection is crucial for resection in rectal cancer, which should be performed by laparoscopy for better outcome. The use of indocyanine green (ICG) fluorescence is now routinely used in some centers to evaluate bowel perfusion. Previous studies have demonstrated in animal models that selective intra-arterial ICG staining can be used to define and visualize resection margins in rectal cancer. In this animal study, we investigate if laparoscopic intra-arterial catheterization is feasible and the staining of resection margins when performing total mesorectal excision with a laparoscopic medial to lateral approach is possible. In 4 pigs, laparoscopic catheterization of the inferior mesenteric artery (IMA) is performed using a seldinger technique. After a bolus injection of 10 ml ICG with a concentration of 0.25 mg/ml, a continuous intra-arterial perfusion was established at a rate of 2 ml/min. The quality of the staining was evaluated qualitatively. Laparoscopic catheterization was possible in all cases, and the average time for this was 30.25 ± 3.54 min. We observed a significant fluorescent signal in all areas of the IMA supplied, but not in other parts of the abdominal cavity or organs. In addition, the mesorectum showed a sharp border between stained and unstained tissue. Intraoperative isolated fluorescence augmentation of the rectum, including the mesorectum by laparoscopic catheterization, is feasible. Inferior mesenteric artery catheterization and ICG perfusion can provide a fluorescence-guided roadmap to identify the correct plane in total mesorectal excision, which should be investigated in further studies.
Collapse
Affiliation(s)
- Christian Heiliger
- Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-University (LMU), Marchioninistrasse 15, 81377, Munich, Germany.
| | - Jerzy Piecuch
- Klinika Chirurgii Ogolnej, Metabolicznej i Medycyny Ratunkowej w Zabrzu, Slaski Universytet Medyczny w Katowicach, Katowicach, Poland
| | - Alexander Frank
- Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-University (LMU), Marchioninistrasse 15, 81377, Munich, Germany
| | - Dorian Andrade
- Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-University (LMU), Marchioninistrasse 15, 81377, Munich, Germany
| | - Viktor von Ehrlich-Treuenstätt
- Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-University (LMU), Marchioninistrasse 15, 81377, Munich, Germany
| | - Dobromira Evtimova
- Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-University (LMU), Marchioninistrasse 15, 81377, Munich, Germany
| | - Florian Kühn
- Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-University (LMU), Marchioninistrasse 15, 81377, Munich, Germany
| | - Jens Werner
- Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-University (LMU), Marchioninistrasse 15, 81377, Munich, Germany
| | - Konrad Karcz
- Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-University (LMU), Marchioninistrasse 15, 81377, Munich, Germany
| |
Collapse
|
2
|
Georgakis GV, Goldberg I, Sasson AR. Current Trends in the Surgical Management of Colorectal Cancer Liver Metastases. CURRENT COLORECTAL CANCER REPORTS 2019. [DOI: 10.1007/s11888-019-00440-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
3
|
Qadan M, D’Angelica MI, Kemeny NE, Cercek A, Kingham TP. Robotic hepatic arterial infusion pump placement. HPB (Oxford) 2017; 19:429-435. [PMID: 28132735 PMCID: PMC5633044 DOI: 10.1016/j.hpb.2016.12.015] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2016] [Revised: 12/10/2016] [Accepted: 12/31/2016] [Indexed: 12/12/2022]
Abstract
BACKGROUND Hepatic artery infusion pump (HAIP) placement is associated with improved outcomes in the treatment of colorectal liver metastases (CRLM). In this study, we examined outcomes following robotic HAIP placement, which were compared with open and laparoscopic placement. METHODS A retrospective review of HAIP placements by 2 surgeons at a single institution was carried out. All statistical tests were 2-sided and p < 0.05 was considered significant. RESULTS There were a total of 53 open HAIP cases, 21 laparoscopic cases, and 24 robotic cases. Robotic HAIP placement was associated with a significantly lower conversion rate to open operation than laparoscopic pump placement (17 vs. 67%; p = 0.0009). When cases with concomitant resections were excluded, there was a trend towards shorter median length of hospital stay with robotic pump placement compared with open and laparoscopic placement (4 vs. 5 vs. 5 days, respectively; p = 0.09). Complication rates were equivalent among the 3 groups when concomitant resections were excluded. CONCLUSION Robotic HAIP placement is a safe minimally-invasive procedure that is associated with a significantly lower conversion rate to open operation compared with laparoscopic placement and a trend towards shorter hospitalization compared with open placement.
Collapse
|
4
|
Dhir M, Zenati MS, Padussis JC, Jones HL, Perkins S, Clifford AK, Steve J, Hogg ME, Choudry HA, Holtzman MP, Zeh HJ, Pingpank JF, Bartlett DL, Zureikat AH. Robotic assisted placement of hepatic artery infusion pump is a safe and feasible approach. J Surg Oncol 2016; 114:342-347. [DOI: 10.1002/jso.24325] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
Affiliation(s)
- Mashaal Dhir
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Mazen S. Zenati
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - James C. Padussis
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Heather L. Jones
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Samantha Perkins
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Amber K. Clifford
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Jennifer Steve
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Melissa E. Hogg
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Haroon A. Choudry
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Matthew P. Holtzman
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Herbert J. Zeh
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - James F. Pingpank
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - David L. Bartlett
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| | - Amer H. Zureikat
- Division of GI Surgical Oncology; Department of Surgery; University of Pittsburgh Medical Center; Pittsburgh Pennsylvania
| |
Collapse
|
5
|
Subramanian M, Choti MA, Yopp AC. Hepatic Arterial Infusion Pump Chemotherapy for Colorectal Liver Metastases: Making a Comeback? CURRENT COLORECTAL CANCER REPORTS 2015. [DOI: 10.1007/s11888-015-0277-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
6
|
Ocuin LM, Tsung A. Robotic liver resection for malignancy: Current status, oncologic outcomes, comparison to laparoscopy, and future applications. J Surg Oncol 2015; 112:295-301. [PMID: 26119652 DOI: 10.1002/jso.23901] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Accepted: 02/07/2015] [Indexed: 12/14/2022]
Abstract
Utilization of robotic techniques for resection of the liver is slowly gaining acceptance in specific situations and is now being applied to more challenging endeavors, such as major hepatectomy for cancer. This review provides a summary of robotic applications in liver surgery, with specific attention perioperative outcomes, oncologic outcomes, cost, and comparison to conventional laparoscopic techniques of liver resection. We also discuss future applications of robotic-assisted liver surgery.
Collapse
Affiliation(s)
- Lee M Ocuin
- Division of Surgical Oncology, Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Allan Tsung
- Division of Hepatobiliary and Pancreatic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| |
Collapse
|
7
|
Abstract
To date, hepatic artery infusion (HAI) chemotherapy has primarily been investigated in the setting of colorectal cancer liver metastases (CRLM). Few studies have been conducted in North America regarding HAI chemotherapy for primary liver cancers (PLC) or noncolorectal liver metastases (non-CRLM). Despite decades of evaluation, controversy surrounding the use of HAI chemotherapy still exists. In this article the methods of HAI chemotherapy delivery, technical aspects of catheter and pump insertion, and specific complications of HAI chemotherapy are discussed. Outcomes of clinical trials and reviews of HAI chemotherapy in the setting of CRLM, PLC, and non-CRLM are evaluated.
Collapse
Affiliation(s)
- Julie N Leal
- Department of Surgery, Division of Hepatopancreatobiliary Surgery, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065, USA
| | - T Peter Kingham
- Department of Surgery, Division of Hepatopancreatobiliary Surgery, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065, USA.
| |
Collapse
|
8
|
|
9
|
Hellan M, Pigazzi A. Robotic-assisted placement of a hepatic artery infusion catheter for regional chemotherapy. Surg Endosc 2007; 22:548-51. [PMID: 17704873 DOI: 10.1007/s00464-007-9496-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2007] [Revised: 05/20/2007] [Accepted: 06/19/2007] [Indexed: 10/22/2022]
Abstract
Hepatic arterial infusion chemotherapy can be of value to patients with metastatic liver disease from colorectal cancer. Arterial infusion therapy requires surgical placement of a catheter into the gastroduodenal artery connected to a subcutaneous infusion pump or port, a procedure involving major abdominal surgery. Placement of chemotherapy infusion catheters by conventional laparoscopic techniques has been described, but is a technically challenging procedure. The purpose of this report is to introduce a new, minimally invasive approach for hepatic artery catheter placement using the DaVinci robotic system with the potential to minimize surgical trauma, pain, and hospital stay, and to render this minimal access procedure more feasible and widely applicable.
Collapse
Affiliation(s)
- Minia Hellan
- Department of General and Oncologic Surgery, City of Hope National Cancer Center, 1500 East Duarte Road, Duarte, CA 91010, USA
| | | |
Collapse
|
10
|
Franklin M, Trevino J, Hernandez-Oaknin H, Fisher T, Berghoff K. Laparoscopic hepatic artery catheterization for regional chemotherapy. Surg Endosc 2006; 20:554-8. [PMID: 16508811 DOI: 10.1007/s00464-005-0486-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2005] [Accepted: 11/25/2005] [Indexed: 10/25/2022]
Abstract
BACKGROUND Metastatic disease isolated to the liver is present at the time of diagnosis in 20-30% of patients with colorectal cancer. Only 10% of patients are eligible for resection. Systemic chemotherapy remains the primary treatment modality for such patients. The morbidity associated with regional chemotherapy is largely a result of the laparotomy required to place a hepatic arterial infusion pump in these debilitated patients. We discuss the main advantages of laparoscopic approach in comparison to both open procedure and percutaneous hepatic artery catheterization. MATERIAL AND METHODS From November 1993 to April 2004, 27 patients (16 males, 11 females) underwent laparoscopic placement of a hepatic artery catheter. The mean age was 64.9 years (46 to 82 years). 24 patients (88.8%) had bilobar disease precluding surgical resection of the liver metastases. There were four cases of non-colon cancers, all with liver metastases. RESULTS LHAC alone averaged 45-55 minutes. Mean blood loss of 151 cc (20-300 cc). Postoperatively, 16 patients (59.2%) had hepatic intra-arterial chemotherapy in the recovery room as a preplanned protocol. Average hospital stay was 8.4 days (3-25 days). Median follow-up period of 8.1 months. 22 patients with residual hepatic disease, in whom chemotherapy was successfully instituted, showed regression of their metastases, in 18 patients, CEA had improved at their one-month follow-up visit. Three complications: one catheter thrombosis, one partial catheter occlusion and one eroded catheter into the duodenum one year after. CONCLUSIONS In experienced hands, laparoscopic hepatic artery catheterization is a safe, feasible and minimally invasive technique for those patients with metachronous liver malignancies.
Collapse
Affiliation(s)
- M Franklin
- Laparoscopic Surgery, Texas Endosurgery Institute, San Antonio, TX 78222, USA.
| | | | | | | | | |
Collapse
|
11
|
Brown DB, Papadouris DC, Davis RV, Vedantham S, Pilgram TK. Power Injection of Microcatheters: An In Vitro Comparison. J Vasc Interv Radiol 2005; 16:101-6. [PMID: 15640416 DOI: 10.1097/01.rvi.0000141718.12025.2c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022] Open
Abstract
PURPOSE To determine the tolerance of 0.021-inch and 0.027-inch microcatheters to power injection in an in vitro flow model. MATERIALS AND METHODS Twenty-four microcatheters (0.021-inch, n = 13; 0.027-inch, n = 11) were injected with iothalamate meglumine through a flow model with use of a power injector and high-pressure tubing. Catheters used included Rebar (0.021-inch, n = 4; 0.027-inch, n = 4), Transit (0.021-inch, n = 3; 0.027-inch, n = 3), Renegade (0.021-inch, n = 4; 0.027-inch, n = 4), and Renegade STC-18 (0.021-inch, n = 2) models. Through the 0.021-inch microcatheters, 5-second injections were performed at an initial rate of 0.7 mL/sec. Injection rates were increased by 0.5 mL/sec and the process was repeated until the pressure approached 1,000 psi or catheter breakage occurred. A similar process was repeated for the 0.027-inch catheters starting at a rate of 3.4 mL/sec. RESULTS The 0.021-inch catheters were injected 303 times and the 0.027-inch catheters were injected 210 times. Three catheter failures occurred, with all breaks occurring at pressures greater than manufacturer recommendations. The 0.027-inch catheters as a group tolerated significantly higher injection rates than the 0.021-inch catheters. Of the 0.021-inch catheters, the STC-18 also provided superior maximum flow and volume compared with the Renegade catheter. The Rebar catheter tolerated significantly lower maximum injection rates and volumes than the other 0.027-inch catheters. CONCLUSIONS The majority of microcatheters can be power-injected in vitro at pressures far greater than manufacturer recommendations. When fractures occur, they are near the hub of the catheter. Significantly greater rates of injection are possible through 0.027-inch catheters.
Collapse
Affiliation(s)
- Daniel B Brown
- Mallinckrodt Institute of Radiology, Washington University Medical Center, 510 South Kingshighway Boulevard, St. Louis, Missouri 63110, USA.
| | | | | | | | | |
Collapse
|
12
|
Cheng J, Hong D, Zhu G, Swanstrom LL, Hansen PD. Laparoscopic Placement of Hepatic Artery Infusion Pumps: Technical Considerations and Early Results. Ann Surg Oncol 2004; 11:589-97. [PMID: 15150068 DOI: 10.1245/aso.2004.05.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND Laparoscopic hepatic artery infusion pump (LHAIP) placement is a novel treatment option for patients with colorectal liver metastases. This study investigates technical difficulties with regard to variant hepatic arteries and the preliminary outcomes for patients treated with LHAIP placement. METHODS Between March 1998 and January 2003, 38 patients with colorectal metastases confined to the liver, 35 (92%) of who had prior systemic chemotherapy that failed, were treated with LHAIP. RESULTS Twelve patients (32%) had LHAIP placement only, and 26 (68%) had pump placement combined with laparoscopic radiofrequency ablation (LRFA; 24 patients) and/or liver resection (2 patients). Variant hepatic arterial (HA) anatomy was present in 18 patients (47%). The presence of a variant HA did not increase pump complications, operative time, or blood loss (P >/=.20) or decrease the functional time of pump use (P =.91) in comparison with normal anatomy. In all patients with a variant HA, laparoscopic ligation of the variant vessel and/or cannulation of nongastroduodenal artery resulted in complete hepatic perfusion. Three misperfusions identified intraoperatively with use of methylene blue injection were corrected by laparoscopic ligation (two) or postoperative angioembolization (one). Postoperative pump radionuclide flow studies confirmed isolated hepatic artery infusion in all cases. There was a 13% pump-related complication rate. During a median follow-up of 11 months (0.5 to 35.5 months), the actuarial rate of overall survival was 47% and the estimated median survival time was 17.5 months. CONCLUSIONS LHAIP placement is technically feasible, and variant HA is not associated with increased pump complications or decreased pump functional time.
Collapse
Affiliation(s)
- Jun Cheng
- General Surgery, TC-29260, University of Michigan Health System, 1500 E. Medical Center Drive, Ann Arbor, MI 48109, USA
| | | | | | | | | |
Collapse
|
13
|
Elias D, de Baere T, Sideris L, Ducreux M. Regional chemotherapeutic techniques for liver tumors: current knowledge and future directions. Surg Clin North Am 2004; 84:607-25. [PMID: 15062664 DOI: 10.1016/s0039-6109(03)00225-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
After a rather long period of stagnation, intra-arterial therapeutic approaches for treating liver tumors are currently progressing rapidly. These new modalities will increase the resectability of initially unresectable liver tumors after dramatic responses. At the same time, resectability rates are increasing with the assistance of local ablative physical treatments such as radiofrequency, resulting in an improvement of patients' median survival rates and quality of life.
Collapse
Affiliation(s)
- Dominique Elias
- Division of Surgical Oncology, Department of Surgery, Gustave Roussy Institute, Rue Camille Desmoulins, 94805, Villejuif, France.
| | | | | | | |
Collapse
|
14
|
Bibliography Current World Literature. Curr Opin Obstet Gynecol 2003. [DOI: 10.1097/01.gco.0000084240.09900.81] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|