Randelli F, Pulici L, Favilla S, Maglione D, Zaolino C, Carminati S, Pace F, Randelli P. Complications related to fracture treatment in HIV patients: a case report.
Injury 2014;
45:379-82. [PMID:
24119651 DOI:
10.1016/j.injury.2013.09.026]
[Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/18/2013] [Indexed: 02/02/2023]
Abstract
We present the case report of a 40-year-old woman who was HIV-positive in Highly Active Anti-Retroviral Therapy (HAART) and affected by femural pertrochanteric fracture, which was treated by endomedullary nailing. Two years after the surgical operation, the woman developed an aseptic symptomatic osteolysis around the implant. Hardware removal was resolutive. Aseptic and septic hardware mobilization, hardware removal, and implant decision in HIV patients with pertrochanteric fractures is discussed. The authors suggest close follow-up and prompt hardware removal, as soon as X-rays demonstrate healing signs, in HIV patients with fracture fixation, if general condition allows.
Collapse