• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4611578)   Today's Articles (6963)   Subscriber (49382)
For: Fassett DR, Apfelbaum R, Clark R, Bachus KN, Brodke DS. Biomechanical analysis of a new concept: an add-on dynamic extension plate for adjacent-level anterior cervical fusion. Spine (Phila Pa 1976) 2005;30:2523-9. [PMID: 16284590 DOI: 10.1097/01.brs.0000186319.84883.e7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Number Cited by Other Article(s)
1
Costi JJ, Ledet EH, O'Connell GD. Spine biomechanical testing methodologies: The controversy of consensus vs scientific evidence. JOR Spine 2021;4:e1138. [PMID: 33778410 PMCID: PMC7984003 DOI: 10.1002/jsp2.1138] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 12/04/2020] [Accepted: 12/07/2020] [Indexed: 12/14/2022]  Open
2
Lee CH, Hsu CC, Chaing L. An Optimization Study for the Bone-Implant Interface Performance of Lumbar Vertebral Body Cages Using a Neurogenetic Algorithm and Verification Experiment. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0306-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
3
An In Vitro Biomechanical Study Evaluating Cervical Extension Plates for Stabilizing Degenerated Adjacent Levels. Clin Spine Surg 2017;30:E44-E48. [PMID: 28107242 DOI: 10.1097/bsd.0b013e3182a26734] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
4
Calvert GC, Lawrence BD, Abtahi AM, Bachus KN, Brodke DS. Cortical screws used to rescue failed lumbar pedicle screw construct: a biomechanical analysis. J Neurosurg Spine 2014;22:166-72. [PMID: 25478820 DOI: 10.3171/2014.10.spine14371] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
5
A biomechanical evaluation of a spacer with integrated plate for treating adjacent-level disease in the subaxial cervical spine. Spine J 2012;12:585-9. [PMID: 22964012 DOI: 10.1016/j.spinee.2012.07.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2011] [Revised: 04/12/2012] [Accepted: 07/06/2012] [Indexed: 02/03/2023]
6
Anterior corpectomy and reconstruction with titanium mesh cage and dynamic cervical plate for cervical spondylotic myelopathy in elderly osteoporosis patients. Arch Orthop Trauma Surg 2011;131:1369-74. [PMID: 21573884 DOI: 10.1007/s00402-011-1317-2] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2010] [Indexed: 10/18/2022]
7
Ferrara LA, Goel VK. The biomechanics of spinal fusion. ACTA ACUST UNITED AC 2010. [DOI: 10.1007/s12240-010-0013-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
8
Wang M, Gourab K, McGrady LM, Rao RD. Alteration of load sharing of anterior cervical implants with change in cervical sagittal alignment. Med Eng Phys 2008;30:768-73. [DOI: 10.1016/j.medengphy.2007.10.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2007] [Revised: 10/03/2007] [Accepted: 10/05/2007] [Indexed: 12/01/2022]
9
Panjabi M, Henderson G, Abjornson C, Yue J. Multidirectional testing of one- and two-level ProDisc-L versus simulated fusions. Spine (Phila Pa 1976) 2007;32:1311-9. [PMID: 17515820 DOI: 10.1097/brs.0b013e318059af6f] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA