1
|
Zanardo V, Straface G. Intrapartum cardiotocography. Am J Obstet Gynecol 2024; 231:e114. [PMID: 38734361 DOI: 10.1016/j.ajog.2024.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Accepted: 05/06/2024] [Indexed: 05/13/2024]
Affiliation(s)
- Vincenzo Zanardo
- Division of Perinatal Medicine, Abano Polyclinic, Piazza Colombo 1, 35031 Abano Terme, Italy.
| | - Gianluca Straface
- Division of Perinatal Medicine, Abano Polyclinic, Piazza Colombo 1, 35031 Abano Terme, Italy
| |
Collapse
|
2
|
Blix E, Brurberg KG, Reierth E, Reinar LM, Øian P. ST waveform analysis vs cardiotocography alone for intrapartum fetal monitoring: An updated systematic review and meta-analysis of randomized trials. Acta Obstet Gynecol Scand 2024; 103:437-448. [PMID: 38093630 PMCID: PMC10867373 DOI: 10.1111/aogs.14752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 10/25/2023] [Accepted: 11/23/2023] [Indexed: 02/16/2024]
Abstract
INTRODUCTION ST waveform analysis (STAN) was introduced as an adjunct to cardiotocography (CTG) to improve neonatal and maternal outcomes. The aim of the present study was to quantify the efficacy of STAN vs CTG and assess the quality of the evidence using GRADE. MATERIAL AND METHODS We performed systematic literature searches to identify randomized controlled trials and assessed included studies for risk of bias. We performed meta-analyses, calculating pooled risk ratio (RR) or Peto odds ratio (OR). We also performed post hoc trial sequential analyses for selected outcomes to assess the risk of false-positive results and the need for additional studies. RESULTS Nine randomized controlled trials including 28 729 women were included in the meta-analysis. There were no differences between the groups in operative deliveries for fetal distress (10.9 vs 11.1%; RR 0.96; 95% confidence interval [CI] 0.82-1.11). STAN was associated with a significantly lower rate of metabolic acidosis (0.45% vs 0.68%; Peto OR 0.66; 95% CI 0.48-0.90). Accordingly, 441 women need to be monitored with STAN instead of CTG alone to prevent one case of metabolic acidosis. Women allocated to STAN had a reduced risk of fetal blood sampling compared with women allocated to conventional CTG monitoring (12.5% vs 19.6%; RR 0.62; 95% CI 0.49-0.80). The quality of the evidence was high to moderate. CONCLUSIONS Absolute effects of STAN were minor and the clinical significance of the observed reduction in metabolic acidosis is questioned. There is insufficient evidence to state that STAN as an adjunct to CTG leads to important clinical benefits compared with CTG alone.
Collapse
Affiliation(s)
- Ellen Blix
- Faculty of Health SciencesOslo Metropolitan UniversityOsloNorway
| | - Kjetil Gundro Brurberg
- The Norwegian Institute of Public HealthOsloNorway
- Center for Evidence Based PracticeWestern Norway University of Applied SciencesBergenNorway
| | - Eirik Reierth
- Science and Health LibraryUniversity Library, UiT The Arctic University of NorwayTromsøNorway
| | | | - Pål Øian
- Department of Obstetrics and GynecologyUniversity Hospital of North NorwayTromsøNorway
| |
Collapse
|
3
|
Blix E, Eskild A, Skau I, Grytten J. The impact of the introduction of intrapartum fetal ECG ST segment analysis. A population study. Acta Obstet Gynecol Scand 2022; 101:809-818. [PMID: 35288935 PMCID: PMC9564625 DOI: 10.1111/aogs.14347] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 02/17/2022] [Accepted: 02/25/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION ST segment analysis (STAN) of the fetal electrocardiogram was introduced as an adjunct to cardiotocography for intrapartum fetal monitoring 30 years ago. We examined the impact of the introduction of STAN on changes in the occurrence of fetal and neonatal deaths, Apgar scores of <7 at 5 min, intrapartum cesarean sections, and instrumental vaginal deliveries while controlling for time- and hospital-specific trends and maternal risk factors. MATERIAL AND METHODS Data were retrieved from the Medical Birth Registry of Norway from 1985 to 2014. Individual data were linked to the Education Registry and the Central Person Registry. The study sample included 1 132 022 singleton births with a gestational age of 36 weeks or beyond. Information about the year of STAN introduction was collected from every birth unit in Norway using a questionnaire. Our data structure consisted of a hospital-year panel. We applied a linear probability model with hospital-fixed effects and with adjustment for potentially confounding factors. The prevalence of the outcomes before and after the introduction of STAN were compared within each birth unit. RESULTS In total, 23 birth units, representing 76% of all births in Norway, had introduced the STAN technology. During the study period, stillbirths declined from 2.6 to 1.9 per 1000 births, neonatal deaths declined from 1.7 to 0.7 per 1000 live births, babies with Apgar score <7 at 5 min after birth increased from 7.4 to 9.5 per 1000 births, intrapartum cesarean sections increased from 6.4% to 9.5%, and instrumental vaginal deliveries increased from 7.8% to 10.9%. Our analyses found that the introduction of STAN was not associated with the decline in proportion of stillbirths (p =0.76) and neonatal deaths (p =0.76) or with the increase in intrapartum cesarean sections (p =0.92) and instrumental vaginal deliveries (p =0.78). However, it was associated with the increased occurrence of Apgar score <7 at 5 min (p =0.01). CONCLUSIONS There is no evidence that the introduction of STAN contributed to changes in the rates of stillbirths, neonatal deaths, intrapartum cesarean sections, or instrumental vaginal deliveries. There was an association between the introduction of STAN and a small increase in neonates with low Apgar scores.
Collapse
Affiliation(s)
- Ellen Blix
- Faculty of Health SciencesOsloMet – Oslo Metropolitan UniversityOsloNorway
| | - Anne Eskild
- Akershus University HospitalLørenskogNorway
- Institute of Clinical MedicineUniversity of OsloOsloNorway
| | - Irene Skau
- Department of Community DentistryUniversity of OsloOsloNorway
| | - Jostein Grytten
- Department of Community DentistryUniversity of OsloOsloNorway
| |
Collapse
|
4
|
Braginsky L, Weiner SJ, Saade GR, Varner MW, Blackwell SC, Reddy UM, Thorp JM, Tita AT, Miller RS, McKenna DS, Chien EK, Rouse DJ, El-Sayed YY, Sorokin Y, Caritis SN. Intrapartum Fetal Electrocardiogram in Small- and Large-for-Gestational Age Fetuses. Am J Perinatol 2021; 38:1465-1471. [PMID: 34464982 PMCID: PMC8608729 DOI: 10.1055/s-0041-1735285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE This study aimed to evaluate whether intrapartum fetal electrocardiogram (ECG) tracings with ST-elevation or depression occur more frequently in each stage of labor in small-for-gestational age (SGA) or large-for-gestational age (LGA), as compared with appropriate-for-gestational age (AGA) fetuses. STUDY DESIGN We conducted a secondary analysis of a large, multicenter trial in which laboring patients underwent fetal ECG waveform-analysis. We excluded participants with diabetes mellitus and major fetal anomalies. Birth weight was categorized as SGA (<10th percentile), LGA (>90th percentile), or AGA (10-90th percentile) by using a gender and race/ethnicity specific nomogram. In adjusted analyses, the frequency of ECG tracings with ST-depression or ST-elevation without depression was compared according to birthweight categories and labor stage. RESULTS Our study included 4,971 laboring patients in the first stage and 4,074 in the second stage. During the first stage of labor, there were no differences in the frequency of ST-depression in SGA fetuses compared with AGA fetuses (6.7 vs. 5.5%; adjusted odds ratio [aOR]: 1.41, 95% confidence interval [CI]: 0.93-2.13), or in ST-elevation without depression (35.8 vs. 34.1%; aOR: 1.17, 95% CI: 0.94-1.46). During the second stage, there were no differences in the frequency of ST-depression in SGA fetuses compared with AGA fetuses (1.6 vs. 2.0%; aOR: 0.69, 95% CI: 0.27-1.73), or in ST-elevation without depression (16.2 vs. 18.1%; aOR: 0.90, 95% CI: 0.67-1.22). During the first stage of labor, there were no differences in the frequency of ST-depression in LGA fetuses compared with AGA fetuses (6.3 vs. 5.5%; aOR: 0.97, 95% CI: 0.60-1.57), or in ST-elevation without depression (33.1 vs. 34.1%; aOR: 0.80, 95% CI: 0.62-1.03); during the second stage of labor, the frequency of ST-depression in LGA compared with AGA fetuses (2.5 vs. 2.0%, aOR: 1.36, 95% CI: 0.61-3.03), and in ST-elevation without depression (15.5 vs. 18.1%; aOR: 0.83, 95% CI: 0.58-1.18) were similar as well. CONCLUSION The frequency of intrapartum fetal ECG tracings with ST-events is similar among SGA, AGA, and LGA fetuses. KEY POINTS · SGA and LGA neonates are at increased risk of cardiac dysfunction.. · Fetal ECG has been used to evaluate fetal response to hypoxia.. · Fetal ST-elevation and ST-depression occur during hypoxia.. · Frequency of intrapartum ST-events is similar among SGA, AGA and LGA fetuses..
Collapse
Affiliation(s)
- Lena Braginsky
- Departments of Obstetrics and Gynecology, Northwestern University, Chicago, Illinois
| | - Steven J. Weiner
- Departments of Obstetrics and Gynecology, George Washington University Biostatistics Center, Washington, District of Columbia
| | - George R. Saade
- Departments of Obstetrics and Gynecology, University of Texas Medical Branch, Galveston, Texas
| | - Michael W. Varner
- Departments of Obstetrics and Gynecology, University of Utah Health Sciences Center, Salt Lake City, Utah
| | - Sean C. Blackwell
- Departments of Obstetrics and Gynecology, University of Texas Health Science Center at Houston, McGovern Medical School-Children's Memorial Hermann Hospital, Houston, Texas
| | - Uma M. Reddy
- Departments of Obstetrics and Gynecology, The Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, Maryland
| | - John M. Thorp
- Departments of Obstetrics and Gynecology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Alan T.N. Tita
- Departments of Obstetrics and Gynecology, University of Alabama at Birmingham, Birmingham, Alabama
| | - Russell S. Miller
- Departments of Obstetrics and Gynecology, Columbia University, New York City, New York
| | - David S. McKenna
- Departments of Obstetrics and Gynecology, The Ohio State University, Columbus, Ohio
| | - Edward K.S. Chien
- Departments of Obstetrics and Gynecology, MetroHealth Medical Center-Case Western Reserve University, Cleveland, Ohio
| | - Dwight J. Rouse
- Departments of Obstetrics and Gynecology, Brown University, Providence, Rhode Island
| | - Yasser Y. El-Sayed
- Departments of Obstetrics and Gynecology, Stanford University, Stanford, California
| | - Yoram Sorokin
- Departments of Obstetrics and Gynecology, Wayne State University, Detroit, Michigan
| | - Steve N. Caritis
- Departments of Obstetrics and Gynecology, University of Pittsburgh, Pittsburgh, Pennsylvania
| | | |
Collapse
|
5
|
Blix E, Brurberg KG, Reierth E, Reinar LM, Øian P. ST waveform analysis versus cardiotocography alone for intrapartum fetal monitoring: a systematic review and meta-analysis of randomized trials. Acta Obstet Gynecol Scand 2015; 95:16-27. [DOI: 10.1111/aogs.12828] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Accepted: 11/18/2015] [Indexed: 11/27/2022]
Affiliation(s)
- Ellen Blix
- Faculty of Health Sciences; Oslo and Akershus University College of Applied Sciences; Oslo Norway
| | - Kjetil G. Brurberg
- The Norwegian Knowledge Center for the Health Services; Oslo Norway
- Center for Evidence Based Practice; Bergen University College; Bergen Norway
| | - Eirik Reierth
- Science and Health Library; University Library; UiT The Arctic University of Norway; Tromsø Norway
| | - Liv M. Reinar
- The Norwegian Knowledge Center for the Health Services; Oslo Norway
| | - Pål Øian
- Department of Obstetrics and Gynecology; University Hospital of North Norway; Tromsø Norway
- Department of Clinical Medicine; UiT The Arctic University of Norway; Tromsø Norway
| |
Collapse
|
6
|
S1-Guideline on the Use of CTG During Pregnancy and Labor: Long version - AWMF Registry No. 015/036. Geburtshilfe Frauenheilkd 2014; 74:721-732. [PMID: 27065483 PMCID: PMC4812878 DOI: 10.1055/s-0034-1382874] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
|
7
|
Oian P, Blix E. Scarce scientific evidence for the use of cardiotocography plus fetal ECG ST interval analysis (STAN). Acta Obstet Gynecol Scand 2014; 93:570. [PMID: 24806376 DOI: 10.1111/aogs.12414] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Pål Oian
- Women's Health and Perinatology Research Group, University of Tromsø, Tromsø, Norway; Department of Obstetrics and Gynecology, University Hospital of Northern Norway, Tromsø, Norway
| | | |
Collapse
|
8
|
Abstract
Magnetocardiography is a noninvasive contactless method to measure the magnetic field generated by the same ionic currents that create the electrocardiogram. The time course of magnetocardiographic and electrocardiographic signals are similar. However, compared with surface potential recordings, multichannel magnetocardiographic mapping (MMCG) is a faster and contactless method for 3D imaging and localization of cardiac electrophysiologic phenomena with higher spatial and temporal resolution. For more than a decade, MMCG has been mostly confined to magnetically shielded rooms and considered to be at most an interesting matter for research activity. Nevertheless, an increasing number of papers have documented that magnetocardiography can also be useful to improve diagnostic accuracy. Most recently, the development of standardized instrumentations for unshielded MMCG, and its ease of use and reliability even in emergency rooms has triggered a new interest from clinicians for magnetocardiography, leading to several new installations of unshielded systems worldwide. In this review, clinical applications of magnetocardiography are summarized, focusing on major milestones, recent results of multicenter clinical trials and indicators of future developments.
Collapse
Affiliation(s)
- Riccardo Fenici
- Clinical Physiology - Biomagnetism Center, Catholic University of Sacred Heart, Rome, Italy.
| | | | | |
Collapse
|
9
|
Chudáček V, Spilka J, Janků P, Koucký M, Lhotská L, Huptych M. Automatic evaluation of intrapartum fetal heart rate recordings: a comprehensive analysis of useful features. Physiol Meas 2011; 32:1347-60. [PMID: 21765204 DOI: 10.1088/0967-3334/32/8/022] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Cardiotocography is the monitoring of fetal heart rate (FHR) and uterine contractions (TOCO), used routinely since the 1960s by obstetricians to detect fetal hypoxia. The evaluation of the FHR in clinical settings is based on an evaluation of macroscopic morphological features and so far has managed to avoid adopting any achievements from the HRV research field. In this work, most of the features utilized for FHR characterization, including FIGO, HRV, nonlinear, wavelet, and time and frequency domain features, are investigated and assessed based on their statistical significance in the task of distinguishing the FHR into three FIGO classes. We assess the features on a large data set (552 records) and unlike in other published papers we use three-class expert evaluation of the records instead of the pH values. We conclude the paper by presenting the best uncorrelated features and their individual rank of importance according to the meta-analysis of three different ranking methods. The number of accelerations and decelerations, interval index, as well as Lempel-Ziv complexity and Higuchi's fractal dimension are among the top five features.
Collapse
Affiliation(s)
- V Chudáček
- Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, the Czech Republic.
| | | | | | | | | | | |
Collapse
|
10
|
|
11
|
Rzepka R, Torbé A, Kwiatkowski S, Blogowski W, Czajka R. Clinical Outcomes of High-risk Labours Monitored Using Fetal Electrocardiography. ANNALS OF THE ACADEMY OF MEDICINE, SINGAPORE 2010. [DOI: 10.47102/annals-acadmedsg.v39n1p27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Objectives: The aim of the study was to review clinical and laboratory outcomes of a cohort of fetuses monitored during high-risk labours, simultaneously by fetal electrocardiography (FECG) and routine cardiotocography (CTG). Materials and Methods: Eighty-three parturients from the Department of Obstetrics and Gynecology of Medical University were included in the clinical study. Inclusive criteria to the study group were: (i) singleton pregnancy at term (between 37 and 42 weeks’ gestation), (ii) longitudinal fetal lying, (iii) more than 2500 g of estimated fetal weight, (iv) meconium-stained liquor, and (v) induction of labour due to fetal indications. Fetal outcome parameters analysed included Apgar scores at 1st, 5th and 10th minute after birth, cord artery acid-base assessment and lactate concentrations analysis. FECG was performed during labour, until the neonate was born, with the use of single spiral scalp electrode connected to the STAN S21 heart monitor. Immediately after delivery, arterial cord blood gas and venous cord blood lactate’s concentrations were analysed. Results: The sensitivity (100%), specificity (97%), negative predictive value (NPV) (100%) and positive predictive value (33%) were higher for FECG than for CTG. Moreover, several significant correlations between episodic/baseline T/QRS ratio rises and cord artery acid-base as well as lactate concentrations were demonstrated. Conclusions: Correlations between episodic/baseline T/QRS ratio rises and fetal outcome parameters indicate that observed changes in FECG reflect neonatal metabolic lactate acidosis. The high sensitivity, specificity and especially very high NPV are proof that FECG serves as a reliable method for electronic fetal monitoring during high-risk labours.
Key words: Fetal asphyxia, STAN system
Collapse
|
12
|
Rault S, Vayssiere C, Roth E, David E, Favre R, Langer B. Assessment of STAN S21 fetal heart monitor by medical staff. Int J Gynaecol Obstet 2008; 102:8-11. [DOI: 10.1016/j.ijgo.2008.01.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2007] [Revised: 01/16/2008] [Accepted: 01/29/2008] [Indexed: 11/24/2022]
|
13
|
Abstract
Routine interventions during labor and birth, such as perineal shaving and enemas before vaginal delivery, continuous intrapartum electronic fetal monitoring (EFM), and episiotomy are prevalent in Taiwan, but they may not always be necessary. Numerous studies investigating these interventions have failed to find absolute benefits for women with uncomplicated and low-risk pregnancies. No evidence-based benefits support routine perineal shaving or enemas during labor for reducing the risk of perineal wound infection or neonatal infection. The use of EFM is associated with an increased rate of operative interventions (vacuum, forceps, cesarean delivery) but does not result in a significant decrease in the incidence of perinatal death or cerebral palsy. Routine episiotomy does not have demonstrable advantages over restrictive episiotomy in the frequency or severity of perineal damage or pelvic relaxation.
Collapse
Affiliation(s)
- Chen-Yu Chen
- Department of Obstetrics and Gynecology, Mackay Memorial Hospital, Taipei, Taiwan
| | | |
Collapse
|