1
|
Ippolito D, Riva L, Talei Franzesi C, De Vito A, Cangiotti C, Crespi A, Corso R, Sironi S. Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol. J Comput Assist Tomogr 2020; 44:13-19. [PMID: 31939876 DOI: 10.1097/rct.0000000000000965] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To evaluate image quality and radiation dose exposure of low-kV setting and low-volume contrast medium (CM) computed tomography angiography (CTA) protocol for transcatheter aortic valve implantation (TAVI) planning in comparison with standard CTA protocol. METHODS Sixty-patients were examined with 256-row MDCT for TAVI planning: 32 patients (study group) were evaluated using 80-kV electrocardiogram-gated protocol with 60 mL of CM and IMR reconstruction; 28 patients underwent a standard electrocardiogram-gated CTA study (100 kV; 80 mL of CM; iDose4 reconstruction). Subjective and objective image quality was evaluated in each patient at different aortic levels. Finally, we collected radiation dose exposure data (CT dose index and dose-length product) of both groups. RESULTS In study protocol, significant higher mean attenuation values were achieved in all measurements compared with the standard protocol. There were no significant differences in the subjective image quality evaluation in both groups. Mean dose-length product of study group was 56% lower than in the control one (P < 0.0001). CONCLUSION Low-kV and low-CM volume CTA, combined with IMR, allows to correctly performing TAVI planning with high-quality images and significant radiation dose reduction compared with standard CTA protocol.
Collapse
Affiliation(s)
| | | | | | | | | | - Andrea Crespi
- Department of Medical Physics, "San Gerardo" Hospital, Monza
| | - Rocco Corso
- From the Department of Diagnostic Radiology, "San Gerardo" Hospital
| | | |
Collapse
|
2
|
Ippolito D, Riva L, Talei Franzesi CR, Cangiotti C, De Vito A, Di Gennaro F, D'andrea G, Crespi A, Sironi S. Diagnostic efficacy of model-based iterative reconstruction algorithm in an assessment of coronary artery in comparison with standard hybrid-Iterative reconstruction algorithm: dose reduction and image quality. LA RADIOLOGIA MEDICA 2019; 124:350-359. [PMID: 30539411 DOI: 10.1007/s11547-018-0964-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Accepted: 11/25/2018] [Indexed: 02/05/2023]
Abstract
PURPOSE To evaluate the image quality and radiation dose exposure of low-dose coronary CTA (cCTA) study, reconstructed with the new model-based iterative reconstruction algorithm (IMR), compared with standard hybrid-iterative reconstruction (iDose4) cCTA in patients with suspected coronary artery disease. MATERIALS AND METHODS Ninety-eight patients with an indication for coronary CT study were prospectively enrolled. Fifty-two patients (study group) underwent 256-MDCT low-dose cCTA (80 kV; automated-mAs; 60 mL of CM, 350 mgL/mL) with prospective ECG-triggering acquisition and IMR. A control group of 46 patients underwent 256-MDCT standard prospective ECG-gated protocol (100 kV; automated-mAs; 70 mL of CM, 400 mgL/mL; iDose4). Subjective and objective image quality (attenuation value, SD, SNR and CNR) were evaluated by two radiologists subjectively. Radiation dose exposure was quantified as DLP, CTDIvol and ED. RESULTS Mean values of mAs were significantly lower for IMR-cCTA (167 ± 62 mAs) compared to iDose-cCTA (278 ± 55 mAs), p < 0.001. With a significant reduction of 38% in radiation dose exposure (DLP: IMR-cCTA 91.7 ± 26 mGy cm vs. iDose-cCTA 148.6 ± 35 mGy cm; p value < 0.001), despite the use of different CM, we found higher mean attenuation values of the coronary arteries in IMR group compared to iDose4 (mean density in LAD: 491HU IMR-cCTA vs. 443HU iDose-cCTA; p = 0.03). We observed a significant higher value of SNR and CNR in study group due to a lower noise level. Qualitative analysis did not reveal any significant differences between the two groups (p = 0.23). CONCLUSIONS Low-dose cCTA study combined with IMR reconstruction allows to correctly evaluate coronary arteries disease, offering high-quality images and significant radiation dose exposure reduction (38%), as compared to standard cCTA protocol.
Collapse
Affiliation(s)
- Davide Ippolito
- Department of Diagnostic Radiology, San Gerardo Hospital, University of Milano-Bicocca, Via Pergolesi 33, 20900, Monza, MB, Italy.
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy.
| | - Luca Riva
- Department of Diagnostic Radiology, San Gerardo Hospital, University of Milano-Bicocca, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Cammillo R Talei Franzesi
- Department of Diagnostic Radiology, San Gerardo Hospital, University of Milano-Bicocca, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Cecilia Cangiotti
- Department of Diagnostic Radiology, San Gerardo Hospital, University of Milano-Bicocca, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Andrea De Vito
- Department of Diagnostic Radiology, San Gerardo Hospital, University of Milano-Bicocca, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Filiberto Di Gennaro
- Department of Diagnostic Radiology, San Gerardo Hospital, University of Milano-Bicocca, Via Pergolesi 33, 20900, Monza, MB, Italy
| | - Gabriele D'andrea
- Department of Diagnostic Radiology, San Gerardo Hospital, University of Milano-Bicocca, Via Pergolesi 33, 20900, Monza, MB, Italy
| | - Andrea Crespi
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
- Department of Medical Physics, San Gerardo Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
| | - Sandro Sironi
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
- Department of Diagnostic Radiology, Papa Giovanni XXIII Hospital, Piazza OMS 1, 24127, Bergamo, Italy
| |
Collapse
|
3
|
Talei Franzesi CR, Ippolito D, Riva L, Fior D, Cangiotti C, Sironi S. Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure. Br J Radiol 2018; 91:20170802. [PMID: 30074831 PMCID: PMC6319841 DOI: 10.1259/bjr.20170802] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE: To evaluate image quality and radiation dose exposure of low-kV (100 kV) and low contrast medium (CM) volume CT angiography (CTA) in patients candidate to Transcatheter Aortic Valve Implantation (TAVI), in comparison with standard CTA protocol. METHODS: 79 patients candidate for TAVI were prospectively enrolled in this study and examined with 256-MDCT. 42 patients were evaluated using study-group protocol (100 kV; whole-body retrospective ECG-gating; with 50 ml of CM; iterative reconstruction algorithm) while 37 patients underwent a standard CTA study (120 kV; ECG-gating for chest; 100 ml of CM; FBP reconstruction). Overall image quality was evaluated using a 4-point scale. Vascular enhancement (HU) was then assessed in each patient by manually drawing multiple ROIs in lumen of 7 segments of the whole aorta. The radiation dose exposure of both groups was calculated and all data were compared and statistically analyzed. RESULTS: On low-kV protocol, higher mean attenuation values were achieved in all the measurements as compared to standard protocol. There were no significant differences in the image quality evaluation in both groups. Mean radiation dose value of study group was significantly lower than in control group (reduction of 20%). CONCLUSION: Low kV and low CM volume CTA protocols allow TAVI planning to be carried out with high quality images and a significant reduction in the radiation dose as compared to the standard CTA protocol. ADVANCES IN KNOWLEDGE: Low-kV CTA for pre-operative assessment of patients candidates for TAVI, permits to achieve a significant reduction of radiation dose exposure and contrast medium volume, reducing the risk of contrast induced nephropathy.
Collapse
|
5
|
Ippolito D, Talei Franzesi C, Fior D, Bonaffini PA, Minutolo O, Sironi S. Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study. Br J Radiol 2015; 88:20140140. [PMID: 25784185 PMCID: PMC4628465 DOI: 10.1259/bjr.20140140] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE To assess the diagnostic quality of low dose (100 kV) CT angiography (CTA), by using ultra-low contrast medium volume (30 ml), for thoracic and abdominal aorta evaluation. METHODS 67 patients with thoracic or abdominal vascular disease underwent multidetector CT study using a 256 slice scanner, with low dose radiation protocol (automated tube current modulation, 100 kV) and low contrast medium volume (30 ml; 4 ml s(-1)). Density measurements were performed on ascending, arch, descending thoracic aorta, anonymous branch, abdominal aorta, and renal and common iliac arteries. Radiation dose exposure [dose-length product (DLP)] was calculated. A control group of 35 patients with thoracic or abdominal vascular disease were evaluated with standard CTA protocol (automated tube current modulation, 120 kV; contrast medium, 80 ml). RESULTS In all patients, we correctly visualized and evaluated main branches of the thoracic and abdominal aorta. No difference in density measurements was achieved between low tube voltage protocol (mean attenuation value of thoracic aorta, 304 HU; abdominal, 343 HU; renal arteries, 331 HU) and control group (mean attenuation value of thoracic aorta, 320 HU; abdominal, 339; renal arteries, 303 HU). Radiation dose exposure in low tube voltage protocol was significantly different between thoracic and abdominal low tube voltage studies (490 and 324 DLP, respectively) and the control group (thoracic DLP, 1032; abdomen, DLP 1078). CONCLUSION Low-tube-voltage protocol may provide a diagnostic performance comparable with that of the standard protocol, decreasing radiation dose exposure and contrast material volume amount. ADVANCES IN KNOWLEDGE Low-tube-voltage-setting protocol combined with ultra-low contrast agent volume (30 ml), by using new multidetector-row CT scanners, represents a feasible diagnostic tool to significantly reduce the radiation dose delivered to patients and to preserve renal function, while also maintaining adequate diagnostic quality images in assessment of aorta.
Collapse
Affiliation(s)
- D Ippolito
- Department of Diagnostic Radiology, San Gerardo Hospital, Monza, Italy
- School of Medicine, University of Milano-Bicocca, Monza, Italy
| | - C Talei Franzesi
- Department of Diagnostic Radiology, San Gerardo Hospital, Monza, Italy
- School of Medicine, University of Milano-Bicocca, Monza, Italy
| | - D Fior
- Department of Diagnostic Radiology, San Gerardo Hospital, Monza, Italy
- School of Medicine, University of Milano-Bicocca, Monza, Italy
| | - P A Bonaffini
- Department of Diagnostic Radiology, San Gerardo Hospital, Monza, Italy
- School of Medicine, University of Milano-Bicocca, Monza, Italy
| | - O Minutolo
- Department of Diagnostic Radiology, San Gerardo Hospital, Monza, Italy
- School of Medicine, University of Milano-Bicocca, Monza, Italy
| | - S Sironi
- Department of Diagnostic Radiology, San Gerardo Hospital, Monza, Italy
- School of Medicine, University of Milano-Bicocca, Monza, Italy
| |
Collapse
|
6
|
Gardner JB, Fruauff AM, Bhalla S, Katz DS. Computed tomography of nontraumatic thoracoabdominal aortic emergencies. Semin Roentgenol 2013; 49:143-56. [PMID: 24836490 DOI: 10.1053/j.ro.2013.10.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
| | - Alana M Fruauff
- Department of Radiology, Winthrop-University Hospital, Mineola, NY
| | - Sanjeev Bhalla
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO
| | - Douglas S Katz
- Department of Radiology, Winthrop-University Hospital, Mineola, NY.
| |
Collapse
|
7
|
ACR Appropriateness Criteria® pulsatile abdominal mass, suspected abdominal aortic aneurysm. Int J Cardiovasc Imaging 2012; 29:177-83. [PMID: 22644671 PMCID: PMC3550697 DOI: 10.1007/s10554-012-0044-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2012] [Accepted: 03/23/2012] [Indexed: 12/17/2022]
Abstract
Clinical palpation of a pulsating abdominal mass alerts the clinician to the presence of a possible abdominal aortic aneurysm (AAA). Generally an arterial aneurysm is defined as a localized arterial dilatation ≥50% greater than the normal diameter. Imaging studies are important in diagnosing the cause of a pulsatile abdominal mass and, if an AAA is found, in determining its size and involvement of abdominal branches. Ultrasound (US) is the initial imaging modality of choice when a pulsatile abdominal mass is present. Noncontrast computed tomography (CT) may be substituted in patients for whom US is not suitable. When aneurysms have reached the size threshold for intervention or are clinically symptomatic, contrast-enhanced multidetector CT angiography (CTA) is the best diagnostic and preintervention planning study, accurately delineating the location, size, and extent of aneurysm and the involvement of branch vessels. Magnetic resonance angiography (MRA) may be substituted if CT cannot be performed. Catheter arteriography has some utility in patients with significant contraindications to both CTA and MRA. The American College of Radiology Appropriateness Criteria(®) are evidence-based guidelines for specific clinical conditions that are reviewed every 2 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances where evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.
Collapse
|
8
|
Joshi SB, Mendoza DD, Steinberg DH, Goldstein MA, Lopez CF, Raizon A, Weissman G, Satler LF, Pichard AD, Weigold WG. Ultra-Low-Dose Intra-Arterial Contrast Injection for Iliofemoral Computed Tomographic Angiography. JACC Cardiovasc Imaging 2009; 2:1404-11. [DOI: 10.1016/j.jcmg.2009.08.010] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2009] [Revised: 07/30/2009] [Accepted: 08/05/2009] [Indexed: 10/20/2022]
|