1
|
Merola R, Vargas M. Economic Indicators, Quantity and Quality of Health Care Resources Affecting Post-surgical Mortality. J Epidemiol Glob Health 2024; 14:613-620. [PMID: 38801492 PMCID: PMC11442816 DOI: 10.1007/s44197-024-00249-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 05/22/2024] [Indexed: 05/29/2024] Open
Abstract
OBJECTIVE to identify correlations between quality and quantity of health care resources, national economic indicators, and postoperative in-hospital mortality as reported in the EUSOS study. METHODS Different variables were identified from a series of publicly available database. Postoperative in-hospital mortality was identified as reported by EUSOS study. Spearman non-parametric and Coefficients of non-linear regression were calculated. RESULTS Quality of health care resources was strongly and negatively correlated to postoperative in-hospital mortality. Quantity of health care resources were negatively and moderately correlated to postoperative in-hospital mortality. National economic indicators were moderately and negatively correlated to postoperative in-hospital mortality. General mortality, as reported by WHO, was positively but very moderately correlated with postoperative in-hospital mortality. CONCLUSIONS Postoperative in-hospital mortality is strongly determined by quality of health care instead of quantity of health resources and health expenditures. We suggest that improving the quality of health care system might reduce postoperative in-hospital mortality.
Collapse
Affiliation(s)
- Raffaele Merola
- Anesthesia and Intensive Care Medicine, Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", Naples, Italy.
| | - Maria Vargas
- Anesthesia and Intensive Care Medicine, Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", Naples, Italy
| |
Collapse
|
2
|
Huang H, Yan Y, Jiang D, Zhao X, Cao D, She D. Is 3T MR nerve-bone fusion imaging a viable alternative to MRI-CBCT to identify the relationship between the inferior alveolar nerve and mandibular third molar. Clin Oral Investig 2024; 28:256. [PMID: 38630324 DOI: 10.1007/s00784-024-05649-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Accepted: 04/02/2024] [Indexed: 04/19/2024]
Abstract
OBJECTIVES To investigate the feasibility of MRI nerve-bone fusion imaging in assessing the relationship between inferior alveolar nerve (IAN) / mandibular canal (MC) and mandibular third molar (MTM) compared with MRI-CBCT fusion. MATERIALS AND METHODS The MRI nerve-bone fusion and MRI-CBCT fusion imaging were performed in 20 subjects with 37 MTMs. The Hausdorff distance (HD) value and dice similarity coefficient (DSC) was calculated. The relationship between IAN/MC and MTM roots, inflammatory, and fusion patterns were compared between these two fused images. The reliability was assessed using a weighted κ statistic. RESULTS The mean HD and DSC ranged from 0.62 ~ 1.35 and 0.83 ~ 0.88 for MRI nerve-bone fusion, 0.98 ~ 1.50 and 0.76 ~ 0.83 for MRI-CBCT fusion. MR nerve-bone fusion had considerable reproducibility compared to MRI-CBCT fusion in relation classification (MR nerve-bone fusion κ = 0.694, MRI-CBCT fusion κ = 0.644), direct contact (MR nerve-bone fusion κ = 0.729, MRI-CBCT fusion κ = 0.720), and moderate to good agreement for inflammation detection (MR nerve-bone fusion κ = 0.603, MRI-CBCT fusion κ = 0.532, average). The MR nerve-bone fusion imaging showed a lower ratio of larger pattern compared to MR-CBCT fusion (16.2% VS 27.3% in the molar region, and 2.7% VS 5.4% in the retromolar region). And the average time spent on MR nerve-bone fusion and MRI-CBCT fusion was 1 min and 3 min, respectively. CONCLUSIONS Both MR nerve-bone fusion and MRI-CBCT fusion exhibited good consistency in evaluating the spatial relationship between IAN/MC and MTM, fusion effect, and inflammation detection. CLINICAL RELEVANCE MR nerve-bone fusion imaging can be a preoperative one-stop radiation-free examination for patients at high risk for MTM surgery.
Collapse
Affiliation(s)
- Hao Huang
- Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Cha-Zhong Road, Fuzhou, Fujian, 350005, People's Republic of China
- Department of Radiology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212, People's Republic of China
| | - Yalan Yan
- Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Cha-Zhong Road, Fuzhou, Fujian, 350005, People's Republic of China
- Department of Radiology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212, People's Republic of China
| | - Dongmei Jiang
- Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Cha-Zhong Road, Fuzhou, Fujian, 350005, People's Republic of China
- Department of Radiology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212, People's Republic of China
| | - Xiance Zhao
- Philips Healthcare, Shanghai, 200000, People's Republic of China
| | - Dairong Cao
- Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Cha-Zhong Road, Fuzhou, Fujian, 350005, People's Republic of China.
- Department of Radiology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212, People's Republic of China.
- Key Laboratory of Radiation Biology of Fujian Higher Education Institutions, the First Affiliated Hospital, Fujian Medical University, Fuzhou, Fujian, 350005, People's Republic of China.
- Department of Radiology, Fujian Key Laboratory of Precision Medicine for Cancer, the First Affiliated Hospital, Fujian Medical University, Fuzhou, Fujian, 350005, People's Republic of China.
| | - Dejun She
- Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Cha-Zhong Road, Fuzhou, Fujian, 350005, People's Republic of China.
- Department of Radiology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212, People's Republic of China.
- Key Laboratory of Radiation Biology of Fujian Higher Education Institutions, the First Affiliated Hospital, Fujian Medical University, Fuzhou, Fujian, 350005, People's Republic of China.
| |
Collapse
|
3
|
Study on the Effect of MRI in the Diagnosis of Benign and Malignant Thoracic Tumors. DISEASE MARKERS 2021; 2021:3265561. [PMID: 34966464 PMCID: PMC8712135 DOI: 10.1155/2021/3265561] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 11/03/2021] [Accepted: 11/23/2021] [Indexed: 11/18/2022]
Abstract
In order to investigate the effectiveness and accuracy of magnetic resonance imaging (MRI) in the diagnosis of benign and malignant thoracic tumors, the research retrospectively selected 80 patients with thoracic tumors admitted from May 2019 to May 2020 as the study subject and all patients were underwent MRI detection. Using pathological diagnostic results as the gold standard, the research analyzed the detection of benign and malignant thoracic tumors by MRI, as well as the diagnostic sensitivity and specificity. After pathological diagnosis, there were 35 malignant tumors and 45 benign tumors. 41 cases of malignant tumors and 39 cases of benign tumors were diagnosed by MRI, with a diagnostic sensitivity of 80.00%, a diagnostic specificity of 71.11%, and a diagnostic compliance rate of 75.00%. In the MRI diagnosis of tumors in different parts of the chest, the diagnostic sensitivity for lung tumors, mediastinal tumors, chest wall tumors, and esophageal tumors was 83.33%, 71.43%, 83.33%, 75.00%, and 87.50%, respectively, and the specificity was 66.67%, 77.78%, 57.14%, 50.00%, and 91.67% according to and breast tumors, respectively. And the accuracy was 73.33%, 75.00%, 69.23, 62.50%, and 90.00%, respectively, with the highest diagnostic sensitivity, specificity, and accuracy for breast tumors. MRI has a good effect on the diagnosis of benign and malignant thoracic tumors and has a high diagnostic value, which is helpful to identify the location, nature, source, and lesion scope of the tumor. It is safe and worthy of promotion.
Collapse
|
4
|
Khodarahmi I, Fritz J. The Value of 3 Tesla Field Strength for Musculoskeletal Magnetic Resonance Imaging. Invest Radiol 2021; 56:749-763. [PMID: 34190717 DOI: 10.1097/rli.0000000000000801] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
ABSTRACT Musculoskeletal magnetic resonance imaging (MRI) is a careful negotiation between spatial, temporal, and contrast resolution, which builds the foundation for diagnostic performance and value. Many aspects of musculoskeletal MRI can improve the image quality and increase the acquisition speed; however, 3.0-T field strength has the highest impact within the current diagnostic range. In addition to the favorable attributes of 3.0-T field strength translating into high temporal, spatial, and contrast resolution, many 3.0-T MRI systems yield additional gains through high-performance gradients systems and radiofrequency pulse transmission technology, advanced multichannel receiver technology, and high-end surface coils. Compared with 1.5 T, 3.0-T MRI systems yield approximately 2-fold higher signal-to-noise ratios, enabling 4 times faster data acquisition or double the matrix size. Clinically, 3.0-T field strength translates into markedly higher scan efficiency, better image quality, more accurate visualization of small anatomic structures and abnormalities, and the ability to offer high-end applications, such as quantitative MRI and magnetic resonance neurography. Challenges of 3.0-T MRI include higher magnetic susceptibility, chemical shift, dielectric effects, and higher radiofrequency energy deposition, which can be managed successfully. The higher total cost of ownership of 3.0-T MRI systems can be offset by shorter musculoskeletal MRI examinations, higher-quality examinations, and utilization of advanced MRI techniques, which then can achieve higher gains and value than lower field systems. We provide a practice-focused review of the value of 3.0-T field strength for musculoskeletal MRI, practical solutions to challenges, and illustrations of a wide spectrum of gainful clinical applications.
Collapse
Affiliation(s)
- Iman Khodarahmi
- From the Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, NY
| | | |
Collapse
|
5
|
Hu J, Xu B, Cao J, Yang R, Zhang H, Guo H, Situ W, Liu J. Application value of CAIPIRINHA-VIBE with MOCO in liver magnetic resonance examination. Eur J Radiol 2021; 140:109739. [PMID: 33945922 DOI: 10.1016/j.ejrad.2021.109739] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Revised: 04/19/2021] [Accepted: 04/23/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To compare the image quality of VIBE sequence using controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA-VIBE) and using generalized autocalibrating partially parallel acquisitions (GRAPPA-VIBE) in liver magnetic resonance examination, and to evaluate the effect of non-rigid 3D-registration motion correction (MOCO) combined with CAIPIRINHA-VIBE on liver spatial location registration. METHODS A total of 85 patients underwent pre-contrast GRAPPA-VIBE and CAIPIRINHA-VIBE breath-hold scan in the mask phase, and then underwent CAIPIRINHA-VIBE breath-hold scan in arterial phase, portal vein phase and delay phase after administration. After the scanning of four phases of CAIPIRINHA-VIBE completed, 3D images without and with MOCO of each phase were automatically generated. The images quality of GRAPPA-VIBE and CAIPIRINHA-VIBE without MOCO in the mask phase was scored subjectively by two physicians. The number of slices at the top of the diaphragm in the arterial phase was taken as the base slice, and that in the other stages subtracted with the base slice for CAIPIRINHA without and with MOCO. The range of diaphragm movement in each phase was counted by + N/- N statistics. RESULTS The image quality and the scores of CAIPIRINHA-VIBE were significantly higher than those of GRAPPA-VIBE in respiratory motion artifact suppression, liver edge sharpness and intrahepatic vascular sharpness (p < 0.05). The spatial position consistency of the liver with MOCO is significantly better than that without MOCO. CONCLUSION CAIPIRINHA-VIBE with MOCO can be used instead of conventional GRAPPA-VIBE sequence in upper abdominal MRI enhancement examination, especially for patients with poor breath-hold.
Collapse
Affiliation(s)
- Junjiao Hu
- Department of Radiology, The Second Xiangya Hospital, Central South University, No.139 Middle Renmin Road, Changsha, Hunan, 410011, China
| | - Bingren Xu
- Department of Radiology, Shenzhen Nanshan District Shekou People's Hospital, China
| | - Jinbo Cao
- Department of Radiology, Shenzhen Nanshan District Shekou People's Hospital, China
| | - Ru Yang
- Department of Radiology, The Second Xiangya Hospital, Central South University, No.139 Middle Renmin Road, Changsha, Hunan, 410011, China
| | - Huiting Zhang
- MR Scientific Marketing, Siemens Healthcare Ltd., Wuhan, China
| | - Hu Guo
- MR Application, Siemens Healthcare Ltd., Changsha, China
| | - Weijun Situ
- Department of Radiology, The Second Xiangya Hospital, Central South University, No.139 Middle Renmin Road, Changsha, Hunan, 410011, China.
| | - Jun Liu
- Department of Radiology, The Second Xiangya Hospital, Central South University, No.139 Middle Renmin Road, Changsha, Hunan, 410011, China.
| |
Collapse
|
6
|
Abstract
Metastatic bone disease (MBD) is common—it is detected in up to 65–75% of patients with breast or prostate cancer, in over 35% of patients with lung cancer; and almost all patients with symptomatic multiple myeloma have focal lesions or a diffuse bone marrow infiltration. Metastatic bone disease can cause a variety of symptoms and is often associated with a poorer prognosis, with high social and health-care costs. Population-based cohort studies confirm significantly increased health-care utilization costs in patients presenting with cancer with MBD compared with those without MBD. The prolonged survival of patients with bone metastasis thanks to advances in therapy presents an opportunity for better treatments for this patient cohort. Early and accurate diagnosis of bone metastases is therefore crucial. The patterns and presentation of MBD are quite heterogeneous and necessitate good knowledge of the possibilities and limitations of each imaging modality. Here, we review the state-of-the-art imaging techniques, assess the need for evidence-based and cost-effective patient care pathways, and advocate multidisciplinary management based on collaborations between orthopedic surgeons, pathologists, oncologists, radiotherapists, and radiologists aimed at improving patient outcomes. Radiologists play a key role in this multidisciplinary approach to decision-making through correlating the tumor entity, the tumor biology, the impact on the surrounding tissues and progression, as well as the overall condition of the patient. This approach helps to choose the best patient-tailored imaging plan advocating a “choose wisely” strategy throughout the initial diagnosis, minimally invasive treatment procedures, as well as follow-up care plans.
Collapse
|
7
|
Asante S, Acheampong F. Patients' knowledge, perception, and experience during magnetic resonance imaging in Ghana: A single centre study. Radiography (Lond) 2020; 27:622-626. [PMID: 33341380 DOI: 10.1016/j.radi.2020.11.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 11/27/2020] [Accepted: 11/30/2020] [Indexed: 11/25/2022]
Abstract
INTRODUCTION The Magnetic Resonance Imaging (MRI) environment has the potency of inducing anxiety, panic attacks, and claustrophobia in patients with some patients describing it as being placed in a long confining tube. Therefore, having patients that are well-informed concerning the diagnostic tests they are about to undergo can contribute to these patients experiencing reduced anxiety, greater satisfaction, and participation in their care which is key in gaining patients' cooperation and compliance during imaging procedures such as MRI. This study purposed to assess patients' knowledge, perception and experience when undergoing MRI examination. METHODS A prospective quantitative approach was adopted for the study and was conducted in a leading teaching hospital in the Greater Accra region of Ghana. The study involved patients who were referred to undergo MRI examination from June to December 2019. Primary data was collected using closed-ended questionnaires as the research tool. The researchers self-administered and explained the details of the questionnaire thoroughly to all the patients. RESULTS Two hundred and four (51%) out of the 400 respondents were males as compared with 196 (49%) females. The most common age group was 41-60 years with a total number of 156 (39%) participants. 120 (30%) indicated they were schooled on MRI by family and friends, 88 (22%) by their referring clinicians, and 65 (16%) indicated other health personnel as their source of knowledge. 228 (57%) indicated that MRI is not safe for pregnant women, 130 (32.5%) indicated it was whilst 42 (10.5%) were not sure. 208 (52%) of the respondents believed MRI can cause cancer, 140 (35%) responded that it does not whilst 52 (13%) were not sure. Also, 312 (78%) indicated that their doctors did not inform them about the use of the contrast medium. CONCLUSION The study revealed that majority of the respondents were schooled on MRI by family and friends instead of their referring clinicians. Most of these family and friends may not necessarily be qualified health personnel which accounted for more than half of the respondents having a misconception that MRI causes cancer similar to other ionizing imaging modalities. The study further revealed that some referring clinicians did not educate their patients on requested MRI examinations causing radiology staff to spend more time educating them resulting in a decrease in productivity. IMPLICATIONS FOR PRACTICE The study will bring to bear the gaps in patient's knowledge concerning MRI which will help referring clinicians and radiology staff adopt strategies to ensure that patients are well educated on MRI examinations they have been referred to undertake. This will in effect reduce the time spent by radiology staff in educating and gaining patients' compliance during such examinations resulting in a decrease in waiting and scanning time leading to an overall increase in workflow.
Collapse
Affiliation(s)
- S Asante
- Department of Medical Imaging, School of Allied Health Sciences, University of Health and Allied Sciences (UHAS), Ho, Ghana; Radiology Department, Metropolitan Hospital, P.O. Box 174, Cape Coast, Ghana.
| | - F Acheampong
- Department of Basic Sciences, School of Basic & Biomedical Sciences, University of Health and Allied Sciences (UHAS), Ho, Ghana
| |
Collapse
|
8
|
An audit of MRI machines and services in Ghana. Radiography (Lond) 2020; 27:127-131. [PMID: 32723619 DOI: 10.1016/j.radi.2020.07.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 07/02/2020] [Accepted: 07/03/2020] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Magnetic resonance imaging (MRI) is a useful medical imaging modality for the diagnosis and management of patients. However, the huge costs associated with establishing and operating MRI means it may not be readily accessible and affordable for hospitals in developing countries. Little is currently known about the availability of MRI machines in Ghana. Such information may assist in informing future health service development within the country. This study reports on the findings and implications of an audit of MRI machines in Ghana. METHODS A quantitative descriptive cross-sectional survey was conducted involving all MRI machines in Ghana. Data obtained was analyzed using the Statistical Package for Social Sciences (SPSS) version 23. Independent-samples t-test was conducted to compare the mean cost of MRI examinations between privately-owned and state-owned MRI machines in Ghana. RESULTS 18 MRI machines, spread across five regions, are available in Ghana. 15 (83.3%) of the MRI machines are located in the Greater-Accra and Ashanti regions. MRI examinations are more expensive in privately-owned machines compared to state-owned machines (p < 0.05). Four state-owned machines have been non-operational for between three-six years resulting in a revenue loss of GHC 36 million (US$7.2 million). CONCLUSION There are few MRI machines in Ghana and the majority are concentrated in the two largest regions. The increase in MRI machines over the past decade can be attributed to private investment in the sector. IMPLICATIONS FOR PRACTICE This study will inform the Ghana Health Service and other healthcare policy makers in Ghana to increase investment in MRI machines to ensure equitable regional distribution of MRI machines so that patients across Ghana would have access to the diagnostic benefits associated with MRI machines.
Collapse
|
9
|
Technological Advances of Magnetic Resonance Imaging in Today's Health Care Environment. Invest Radiol 2020; 55:531-542. [PMID: 32487969 DOI: 10.1097/rli.0000000000000678] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Today's health care environment is shifting rapidly, driven by demographic change and high economic pressures on the system. Furthermore, modern precision medicine requires highly accurate and specific disease diagnostics in a short amount of time. Future imaging technology must adapt to these challenges.Demographic change necessitates scanner technologies tailored to the needs of an aging and increasingly multimorbid patient population. Accordingly, examination times have to be short enough that diagnostic images can be generated even for patients who can only lie in the scanner for a short time because of pain or with low breath-hold capacity.For economic reasons, the rate of nondiagnostic scans due to artifacts should be reduced as far as possible. As imaging plays an increasingly pivotal role in clinical-therapeutic decision making, magnetic resonance (MR) imaging facilities are confronted with an ever-growing number of patients, emphasizing the need for faster acquisitions while maintaining image quality.Lastly, modern precision medicine requires high and standardized image quality as well as quantifiable data in order to develop image-based biomarkers on which subsequent treatment management can rely.In recent decades, a variety of approaches have addressed the challenges of high throughput, demographic change, and precision medicine in MR imaging. These include field strength, gradient, coil and sequence development, as well as an increasing consideration of artificial intelligence. This article reviews state-of-the art MR technology and discusses future implementation from the perspective of what we know today.
Collapse
|
10
|
Guimaraes L, Babaei Jandaghi A, Menezes R, Grant D, Cattral M, Jhaveri KS. Assessment of biliary anatomy in potential living liver donors: Added value of gadoxetic acid-enhanced T1 MR Cholangiography (MRC) including utilization of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique in comparison to T2W-MRC. Magn Reson Imaging 2020; 70:64-72. [PMID: 32320722 DOI: 10.1016/j.mri.2020.04.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 04/02/2020] [Accepted: 04/15/2020] [Indexed: 12/17/2022]
Abstract
OBJECTIVES To assess the added value of gadoxetic-acid-enhanced T1-weighted magnetic resonance Cholangiography (T1W-MRC) including controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-Volumetric Interpolated Breathhold (VIBE) technique compared to T2-weighted MR Cholangiography (T2W-MRC) in depicting biliary anatomy in potential living liver donors. METHODS Eighty-five potential donors including 34 men with a mean age of 35.6 years (range, 18-55 years) and 51 women with a mean age of 36.7 years (range, 23-57 years), were enrolled in this ethics-approved retrospective study. Image quality for depiction of bile ducts was evaluated by two readers in consensus in 3 separate reading sessions: 1) T2W-MRC alone, 2) T1W-MRC alone (including CAIPI-VIBE and generalized autocalibrating partially parallel acquisitions (GRAPPA)-VIBE techniques, and 3) combined T1W/T2W-MRC. Accuracy of T2W-MRC, T1W-MRC, and combined T1W/T2W-MRC for the identification/classification of the biliary variants was calculated using intraoperative cholangiogram (IOC) as the reference standard. Image quality and reader diagnostic confidence provided by CAIPI-VIBE technique was compared with GRAPPA-VIBE technique. Datasets were compared using the Wilcoxon signed-rank test. RESULTS Image quality for depiction of the bile ducts was significantly superior in the combined T1W/T2W-MRC group, when compared to each of T2W-MRC and T1W-MRC groups independently (P value = 0.001-0.034). The combination of CAIPI-VIBE and GRAPPA-VIBE was superior compared to each of the sequences individually. The accuracy of T2W-MRC and T1W-MRC was 93% and 91%, respectively. T1W-MRC depicted four biliary variants better than T2W-MRC. Two variants not well seen in T2W-MRC were clearly shown on T1W-MRC. CONCLUSION Gadoxetic-acid-enhanced T1W-MRC and conventional T2W-MRC techniques are complementary for depiction of biliary variants in potential liver donors and the combination of the two improves the results. The combination of CAIPI-VIBE and GRAPPA-VIBE techniques appear to be complementary for optimal diagnostic yield of T1W-MRC.
Collapse
Affiliation(s)
- Luis Guimaraes
- Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, University of Toronto, Toronto, ON, Canada
| | - Ali Babaei Jandaghi
- Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, Toronto, ON, Canada
| | - Ravi Menezes
- Joint Department of Medical Imaging, University Health Network, Toronto, ON, Canada
| | - David Grant
- Division of General Surgery, Toronto General Hospital, University of Toronto, Toronto, ON, Canada
| | - Mark Cattral
- Division of General Surgery, Toronto General Hospital, University of Toronto, Toronto, ON, Canada
| | - Kartik S Jhaveri
- Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
11
|
Nam JG, Lee JM, Lee SM, Kang HJ, Lee ES, Hur BY, Yoon JH, Kim E, Doneva M. High Acceleration Three-Dimensional T1-Weighted Dual Echo Dixon Hepatobiliary Phase Imaging Using Compressed Sensing-Sensitivity Encoding: Comparison of Image Quality and Solid Lesion Detectability with the Standard T1-Weighted Sequence. Korean J Radiol 2019; 20:438-448. [PMID: 30799575 PMCID: PMC6389821 DOI: 10.3348/kjr.2018.0310] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Accepted: 09/03/2018] [Indexed: 12/19/2022] Open
Abstract
Objective To compare a high acceleration three-dimensional (3D) T1-weighted gradient-recalled-echo (GRE) sequence using the combined compressed sensing (CS)-sensitivity encoding (SENSE) method with a conventional 3D GRE sequence using SENSE, with respect to image quality and detectability of solid focal liver lesions (FLLs) in the hepatobiliary phase (HBP) of gadoxetic acid-enhanced liver MRI. Materials and Methods A total of 217 patients with gadoxetic acid-enhanced liver MRI at 3T (54 in the preliminary study and 163 in the main study) were retrospectively included. In the main study, HBP imaging was done twice using the standard mDixon-3D-GRE technique with SENSE (acceleration factor [AF]: 2.8, standard mDixon-GRE) and the high acceleration mDixon-3D GRE technique using the combined CS-SENSE technique (CS-SENSE mDixon-GRE). Two abdominal radiologists assessed the two MRI data sets for image quality in consensus. Three other abdominal radiologists independently assessed the diagnostic performance of each data set and its ability to detect solid FLLs in 117 patients with 193 solid nodules and compared them using jackknife alternative free-response receiver operating characteristics (JAFROC). Results There was no significant difference in the overall image quality. CS-SENSE mDixon-GRE showed higher image noise, but lesser motion artifact levels compared with the standard mDixon-GRE (all p < 0.05). In terms of lesion detection, reader-averaged figures-of-merit estimated with JAFROC was 0.918 for standard mDixon-GRE, and 0.953 for CS-SENSE mDixon-GRE (p = 0.142). The non-inferiority of CS-SENSE mDixon-GRE over standard mDixon-GRE was confirmed (difference: 0.064 [−0.012, 0.081]). Conclusion The CS-SENSE mDixon-GRE HBP sequence provided comparable overall image quality and non-inferior solid FFL detectability compared with the standard mDixon-GRE sequence, with reduced acquisition time.
Collapse
Affiliation(s)
- Ju Gang Nam
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea.,Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.
| | - Sang Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Hyo Jin Kang
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Eun Sun Lee
- Department of Radiology, Chung-Ang University Hospital, Seoul, Korea
| | - Bo Yun Hur
- Department of Radiology, National Cancer Center, Goyang, Korea
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - EunJu Kim
- Department of Clinical Science, MR, Philips Healthcare Korea, Seoul, Korea
| | | |
Collapse
|
12
|
Singh N, Hanekom H, Suleman FE. The accuracy of magnetic resonance imaging diagnosis of non-osseous knee injury at Steve Biko Academic Hospital. SA J Radiol 2019; 23:1754. [PMID: 31754541 PMCID: PMC6837829 DOI: 10.4102/sajr.v23i1.1754] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 07/25/2019] [Indexed: 01/13/2023] Open
Abstract
Background Preoperative magnetic resonance imaging (MRI) has internationally been proven to reduce unnecessary knee arthroscopies and assist with surgical planning. This has the advantage of avoiding unnecessary surgery and the associated anaesthetic risk, as well as reducing costs. No data were found in the recently published literature assessing the accuracy of MRI interpretation of knee ligament injury in the public sector locally. Objectives This pilot study aimed to determine the accuracy of MRI in detecting non-osseous knee injury in a resource-limited tertiary-level academic hospital in Pretoria, South Africa, compared to the gold standard arthroscopy findings. Method This was an exploratory retrospective analysis of 39 patients who had MRI and arthroscopy at Steve Biko Academic Hospital (SBAH). True positive, true negative, false positive and false negative results were extrapolated from findings in both modalities and translated into sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for each structure. Results Negative predictive values were recorded as 97%, 81%, 90% and 100% (anterior cruciate ligament [ACL], medial meniscus [MM], lateral meniscus [LM] and posterior cruciate ligament [PCL], respectively), which were comparative to recently published international literature. The PPV results were lower than those previously evaluated at 55%, 58%, 55% and not applicable. The sensitivities and specificities of the ligaments were 83%, 58%, 83% and not applicable; and 87%, 81%, 70% and not applicable, respectively. Conclusion Magnetic resonance imaging was found to be sensitive and specific, with a high NPV noted in all structures evaluated. Negative results can therefore be used to avoid unnecessary surgery to the benefit of the patient and state. The study reiterates that high accuracy can be obtained from MRI on a 1.5-tesla non-dedicated scanner, with interpretation by generalist radiologists.
Collapse
Affiliation(s)
- Nashil Singh
- Department of Radiology, University of Pretoria, Steve Biko Academic Hospital, Pretoria, South Africa
| | - Heleen Hanekom
- Department of Radiology, University of Pretoria, Steve Biko Academic Hospital, Pretoria, South Africa
| | - Farhana E Suleman
- Department of Radiology, University of Pretoria, Steve Biko Academic Hospital, Pretoria, South Africa
| |
Collapse
|
13
|
Free-Breathing Dynamic Contrast-Enhanced Imaging of the Upper Abdomen Using a Cartesian Compressed-Sensing Sequence With Hard-Gated and Motion-State-Resolved Reconstruction. Invest Radiol 2019; 54:728-736. [DOI: 10.1097/rli.0000000000000607] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Liu L, Liu L, Li Y, Huang X, Gu D, Wei B, Su D, Jin G. Ultrasmall superparamagnetic nanoparticles targeting E-selectin: synthesis and effects in mice in vitro and in vivo. Int J Nanomedicine 2019; 14:4517-4528. [PMID: 31354271 PMCID: PMC6590629 DOI: 10.2147/ijn.s199571] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Accepted: 05/01/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose: We developed a contrast agent for targeting E-selectin expression. We detected the agent using magnetic resonance imaging (MRI) in vivo in nude mice that had undergone nasopharyngeal carcinoma (NPC) metastasis. Methods: Sialyl Lewis X (sLeX) was conjugated with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. Hydrodynamic size, polydispersity index, and ζ-potential of USPIO–polyethylene glycol (PEG) nanoparticles and USPIO-PEG-sLeX nanoparticles were measured. Component changes in nanoparticles of USPIO, USPIO-PEG, and USPIO-PEG-sLeX were analyzed by thermogravimetric analysis and Fourier-transform infrared spectroscopy. A model of NPC metastasis to inguinal lymph nodes in nude mice was used to investigate characteristics of the USPIO-PEG-sLeX nanoparticles in vivo. We investigated the ability of the T2* value, change in T2* value (ΔT2* value), and enhancement rate (ER) to assess accumulation of USPIO-PEG-sLeX nanoparticles quantitatively in mice of a metastasis group and control group. Four MRI scans were undertaken for each mouse. The first scan (t0) was done before administration of USPIO-PEG-sLeX nanoparticles (0.1 mL) via the tail vein. The other scans were carried out at 0 (t1), 1 (t2), and 2 hours (t3) postinjection. The mean optical density was used to reflect E-selectin expression. Results: sLeX was labeled onto USPIO successfully. In vivo, there were significant interactions between the groups and time for T2* values after administration of USPIO-PEG-sLeX nanoparticles. Six parameters (T2* at t2, ΔT2* at t1, ΔT2* at t2, ER at t1, ER at t2, and ER at t3) were correlated with the mean optical density. Conclusion: USPIO-PEG-sLeX nanoparticles can be used to assess E-selectin expression quantitatively. Use of such molecular probes could enable detection of early metastasis of NPC, more accurate staging, and treatment monitoring.
Collapse
Affiliation(s)
- Lijuan Liu
- Centre of Imaging Diagnosis, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China
| | - Lu Liu
- Centre of Imaging Diagnosis, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China
| | - Yin Li
- Centre of Imaging Diagnosis, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China
| | - Xiaoxin Huang
- Centre of Imaging Diagnosis, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China
| | - Donglian Gu
- Centre of Imaging Diagnosis, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China
| | - Bo Wei
- Centre of Imaging Diagnosis, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China
| | - Danke Su
- Centre of Imaging Diagnosis, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China
| | - Guanqiao Jin
- Centre of Imaging Diagnosis, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China
| |
Collapse
|
15
|
Toxicity Evaluation of a Novel Magnetic Resonance Imaging Marker, CoCl2-N-Acetylcysteine, in Rats. J Toxicol 2019; 2018:9173452. [PMID: 30631353 PMCID: PMC6304599 DOI: 10.1155/2018/9173452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 08/31/2018] [Accepted: 10/16/2018] [Indexed: 11/18/2022] Open
Abstract
C4 (cobalt dichloride-N-acetylcysteine [1% CoCl2:2% NAC]) is a novel magnetic resonance imaging contrast marker that facilitates visualization of implanted radioactive seeds in cancer brachytherapy. We evaluated the toxicity of C4. Rats were assigned to control (0% CoCl2:NAC), low-dose (0.1% CoCl2:2% NAC), reference-dose (C4), and high-dose (10% CoCl2:2% NAC) groups. Agent was injected into the left quadriceps femoris muscle of the rats. Endpoints were organ and body weights, hematology, and serum chemistry and histopathologic changes of tissues at 48 hours and 28 and 63 days after dosing. Student's t tests were used. No abnormalities in clinical signs, terminal body and organ weights, or hematologic and serum chemistry were noted, and no gross or histopathologic lesions of systemic tissue toxicity were found in any treatment group at any time point studied. At the site of injection, concentration-dependent acute responses were observed in all treatment groups at 48 hours after dosing and were recovered by 28 days. No myofiber degeneration or necrosis was observed at 28 or 63 days in any group. In conclusion, a single intramuscular dose of C4 produced no acute or chronic systemic toxicity or inflammation in rats, suggesting that C4 may be toxicologically safe for clinical use in cancer brachytherapy.
Collapse
|
16
|
Improved Visualization of Juxtaprosthetic Tissue Using Metal Artifact Reduction Magnetic Resonance Imaging. Invest Radiol 2019; 54:23-31. [DOI: 10.1097/rli.0000000000000504] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
17
|
Quantitative Perfusion Analysis of the Rectum Using Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging: Initial Experience and Comparison to Time-Resolved Angiography With Interleaved Stochastic Trajectories. Invest Radiol 2018. [PMID: 28622248 DOI: 10.1097/rli.0000000000000397] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
OBJECTIVES Purpose of this study was to compare the quality of perfusion maps obtained from prototypical free-breathing magnetic resonance imaging (MRI) with continuous golden-angle radial sampling and iterative reconstruction (GRASP) to conventional acquisition using time-resolved angiography with interleaved stochastic trajectories (TWIST) in patients with rectal cancer. MATERIAL AND METHODS Forty cases were included for retrospective analysis. Twenty of the patients received routine multiparametric MRI at 3 T for rectal cancer staging, including perfusion measurement with GRASP or TWIST (10 patients for each technique, including 5 prechemoradiation and 5 postchemoradiation). Twenty patients without history of rectal disease served as control group (10 GRASP, 10 TWIST). GRASP images were reconstructed at temporal resolution of 3.45 seconds (21 spokes/frame). A voxel-by-voxel deconvolution approach was used to determine rectal plasma flow (mL/100 mL per minute). Regions of interest were placed at 3 levels within the tumor and normal rectum (lower, middle, and upper part). The quality of morphologic images, perfusion maps, and arterial input function were scored by 2 blinded radiologists. Independent t tests were applied. RESULTS Three patients of the TWIST control group had to be excluded due to technical failure of the sequence. Significantly higher scores for the perfusion maps and arterial input functions (total cohort) were obtained using GRASP (P < 0.05). Artifacts in the perfusion maps were rated significantly lower than for TWIST (P < 0.05). In the healthy rectum cohort, the average plasma flow of normal rectal wall was 31.78 ± 7.39 mL/100 mL per minute with GRASP, compared with 77.62 ± 34.08 mL/100 mL per minute with TWIST, indicating much lower variance for GRASP. Plasma flow values obtained with both methods enabled distinguishing between normal rectal wall and rectal cancer, both before and after chemoradiation. Morphologic image quality was generally higher with GRASP (P < 0.01). CONCLUSIONS GRASP perfusion imaging can distinguish between normal rectum and rectal cancers with higher image quality and less variance than TWIST. Additional morphologic assessment with high spatial resolution from the GRASP acquisition may increase the accuracy and diagnostic confidence of the examination.
Collapse
|
18
|
αvß3-Integrin-Targeted Magnetic Resonance Imaging for the Assessment of Early Antiangiogenic Therapy Effects in Orthotopic Breast Cancer Xenografts. Invest Radiol 2017; 51:746-755. [PMID: 27082316 DOI: 10.1097/rli.0000000000000278] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVES The aim of this study was to investigate magnetic resonance imaging (MRI) with αvß3-integrin-targeted ultrasmall superparamagnetic iron oxide nanoparticles (RGD-USPIO) for the in vivo monitoring of early antiangiogenic therapy effects in experimental breast cancer. MATERIALS AND METHODS Orthotopic human breast cancer (MDA-MB-231) xenograft-bearing severe combined immunodeficiency mice were imaged before and after a 1-week therapy with the vascular endothelial growth factor receptor-antibody bevacizumab or placebo (n = 10 per group, daily intraperitoneal injections of bevacizumab or a volume-equivalent placebo solution, respectively) on a clinical 3 T scanner (Magnetom Skyra; Siemens Healthcare, Erlangen, Germany) before and 60 minutes after the intravenous injection of RGD-USPIO (P04000; Guerbet, Villepinte, France). R2 relaxometry employing a T2-weighted spin-echo sequence with 4 echo times (echo time, 20/40/60/80 milliseconds; repetition time, 3800 milliseconds; matrix, 128 × 128; field of view, 50 × 50; slice thickness, 1.2 mm; time to acquisition, 25 minutes) was used as semiquantitative measure to determine RGD-USPIO endothelial binding. In addition, the T2-weighted images were used to perform volumetric tumor response assessments. Imaging results were validated by ex vivo multiparametric immunohistochemistry with regard to αvß3-integrin expression, microvascular density (CD31), proliferation (Ki-67), and apoptosis (TUNEL). RESULTS RGD-USPIO endothelial binding was significantly reduced after vascular endothelial growth factor inhibition, compared with the control group in which an increased endothelial binding was detected ([INCREMENT]R2Therapy = -0.80 ± 0.78 s; [INCREMENT]R2Control = +0.27 ± 0.59 s; P = 0.002). Correspondingly, immunohistochemistry revealed a significantly lower αvß3-integrin expression (91 ± 30 vs 357 ± 72; P < 0.001), microvascular density (CD31, 109 ± 46 vs 440 ± 208; P < 0.001), tumor cell proliferation (Ki-67, 4040 ± 1373 vs 6530 ± 1217; P < 0.001), as well as significantly higher apoptosis (TUNEL, 11186 ± 4387 vs 4017 ± 1191; P = 0.004) in the therapy compared with the control group. Contrary to the changes in αvß3-integrin expression detected by RGD-USPIO MRI, morphology-based tumor response assessments did not show a significant intergroup difference in tumor volume development over the course of the experiment (ΔVolTherapy +71 ± 40 μL vs ΔVolControl +125 ± 81 μL; P > 0.05). CONCLUSIONS RGD-USPIO MRI allows for the noninvasive assessment of αvß3-integrin expression in the investigated breast cancer model. RGD-USPIO MRI may be applicable for the in vivo monitoring of early antiangiogenic therapy effects in experimental breast cancer, generating possible complementary molecular imaging biomarkers to morphology-based tumor response assessments.
Collapse
|
19
|
"One-Stop Shop": Free-Breathing Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Kidney Using Iterative Reconstruction and Continuous Golden-Angle Radial Sampling. Invest Radiol 2017; 51:714-719. [PMID: 27299581 DOI: 10.1097/rli.0000000000000299] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
AIMS AND OBJECTIVES The purpose of the present study was to evaluate a recently introduced technique for free-breathing dynamic contrast-enhanced renal magnetic resonance imaging (MRI) applying a combination of radial k-space sampling, parallel imaging, and compressed sensing. The technique allows retrospective reconstruction of 2 motion-suppressed sets of images from the same acquisition: one with lower temporal resolution but improved image quality for subjective image analysis, and one with high temporal resolution for quantitative perfusion analysis. MATERIALS AND METHODS In this study, 25 patients underwent a kidney examination, including a prototypical fat-suppressed, golden-angle radial stack-of-stars T1-weighted 3-dimensional spoiled gradient-echo examination (GRASP) performed after contrast agent administration during free breathing. Images were reconstructed at temporal resolutions of 55 spokes per frame (6.2 seconds) and 13 spokes per frame (1.5 seconds). The GRASP images were evaluated by 2 blinded radiologists. First, the reconstructions with low temporal resolution underwent subjective image analysis: the radiologists assessed the best arterial phase and the best renal phase and rated image quality score for each patient on a 5-point Likert-type scale.In addition, the diagnostic confidence was rated according to a 3-point Likert-type scale. Similarly, respiratory motion artifacts and streak artifacts were rated according to a 3-point Likert-type scale.Then, the reconstructions with high temporal resolution were analyzed with a voxel-by-voxel deconvolution approach to determine the renal plasma flow, and the results were compared with values reported in previous literature. RESULTS Reader 1 and reader 2 rated the overall image quality score for the best arterial phase and the best renal phase with a median image quality score of 4 (good image quality) for both phases, respectively. A high diagnostic confidence (median score of 3) was observed. There were no respiratory motion artifacts in any of the patients. Streak artifacts were present in all of the patients, but did not compromise diagnostic image quality.The estimated renal plasma flow was slightly higher (295 ± 78 mL/100 mL per minute) than reported in previous MRI-based studies, but also closer to the physiologically expected value. CONCLUSIONS Dynamic, motion-suppressed contrast-enhanced renal MRI can be performed in high diagnostic quality during free breathing using a combination of golden-angle radial sampling, parallel imaging, and compressed sensing. Both morphologic and quantitative functional information can be acquired within a single acquisition.
Collapse
|
20
|
Gaddam S, Lemberskiy G, Rosenkrantz AB. Characteristics of the Most Recently Awarded Magnetic Resonance Imaging Patents in the United States. Curr Probl Diagn Radiol 2017; 47:302-304. [PMID: 28843639 DOI: 10.1067/j.cpradiol.2017.07.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Accepted: 07/26/2017] [Indexed: 11/22/2022]
Abstract
PURPOSE To characterize recent magnetic resonance imaging (MRI) technical development and innovation based on data regarding MRI-related patents awarded in 2016. METHODS The US Patent and Trademark Office website was searched for patents awarded in 2016 and an abstract containing "magnetic resonance." Patent characteristics were summarized. An MRI physicist classified patents' themes. RESULTS A total of 423 MRI-related patents were awarded in 2016. Among these, 29% had 1 inventor, 24% had 2 inventors, and 47% had ≥2 inventors. Mean interval between patents being filed and awarded was 1389 ± 559days (range: 167-4029). Most common countries of patents' first assignee were USA (40%), Germany (24%), Netherlands (10%), and Japan (10%). In all, 3% included assignees with different countries (most common collaborators USA and Germany). Patents' first assignee had an industry affiliation in 76% vs an academic affiliation in 21% (4% indeterminate); and 3% had industry-academia collaboration. Patents' most common themes were coils (n = 77), sequence design (n = 65), and noncoil scanner hardware (n = 41). These top themes were similar for USA, international, and industry-based patents; however, for academic-based patents, the most common themes were sequence design, reconstruction, and exogenous agents. Less common themes included image analysis, postprocessing, spectroscopy, relaxometry, diffusion, motion correction, radiation therapy, implants, wireless devices, and positron emission tomography-MRI. CONCLUSION Most MRI-related patents were by non-US inventors. A large majority had industry affiliation; minimal industry-academic collaborationwas observed. Patents from industry and academic inventors had distinct top focuses: hardware and software, respectively. Awarenessofthe most recent years' MRI patents may provide insights into forthcoming clinical translations and help guide ongoing research and entrepreneurism.
Collapse
Affiliation(s)
- Sushma Gaddam
- Department of Radiology, Center for Biomedical Imaging, NYU School of Medicine, NYU Langone Medical Center, New York, NY
| | - Gregory Lemberskiy
- Department of Radiology, Center for Biomedical Imaging, NYU School of Medicine, NYU Langone Medical Center, New York, NY; Sackler Institute of Graduate Biomedical Sciences, NYU School of Medicine, NYU Langone Medical Center, New York, NY
| | - Andrew B Rosenkrantz
- Department of Radiology, Center for Biomedical Imaging, NYU School of Medicine, NYU Langone Medical Center, New York, NY.
| |
Collapse
|
21
|
Quantitative computer-aided diagnostic algorithm for automated detection of peak lesion attenuation in differentiating clear cell from papillary and chromophobe renal cell carcinoma, oncocytoma, and fat-poor angiomyolipoma on multiphasic multidetector computed tomography. Abdom Radiol (NY) 2017; 42:1919-1928. [PMID: 28280876 DOI: 10.1007/s00261-017-1095-6] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE To evaluate the performance of a novel, quantitative computer-aided diagnostic (CAD) algorithm on four-phase multidetector computed tomography (MDCT) to detect peak lesion attenuation to enable differentiation of clear cell renal cell carcinoma (ccRCC) from chromophobe RCC (chRCC), papillary RCC (pRCC), oncocytoma, and fat-poor angiomyolipoma (fp-AML). MATERIALS AND METHODS We queried our clinical databases to obtain a cohort of histologically proven renal masses with preoperative MDCT with four phases [unenhanced (U), corticomedullary (CM), nephrographic (NP), and excretory (E)]. A whole lesion 3D contour was obtained in all four phases. The CAD algorithm determined a region of interest (ROI) of peak lesion attenuation within the 3D lesion contour. For comparison, a manual ROI was separately placed in the most enhancing portion of the lesion by visual inspection for a reference standard, and in uninvolved renal cortex. Relative lesion attenuation for both CAD and manual methods was obtained by normalizing the CAD peak lesion attenuation ROI (and the reference standard manually placed ROI) to uninvolved renal cortex with the formula [(peak lesion attenuation ROI - cortex ROI)/cortex ROI] × 100%. ROC analysis and area under the curve (AUC) were used to assess diagnostic performance. Bland-Altman analysis was used to compare peak ROI between CAD and manual method. RESULTS The study cohort comprised 200 patients with 200 unique renal masses: 106 (53%) ccRCC, 32 (16%) oncocytomas, 18 (9%) chRCCs, 34 (17%) pRCCs, and 10 (5%) fp-AMLs. In the CM phase, CAD-derived ROI enabled characterization of ccRCC from chRCC, pRCC, oncocytoma, and fp-AML with AUCs of 0.850 (95% CI 0.732-0.968), 0.959 (95% CI 0.930-0.989), 0.792 (95% CI 0.716-0.869), and 0.825 (95% CI 0.703-0.948), respectively. On Bland-Altman analysis, there was excellent agreement of CAD and manual methods with mean differences between 14 and 26 HU in each phase. CONCLUSION A novel, quantitative CAD algorithm enabled robust peak HU lesion detection and discrimination of ccRCC from other renal lesions with similar performance compared to the manual method.
Collapse
|
22
|
Dournes G, Berger P, Refait J, Macey J, Bui S, Delhaes L, Montaudon M, Corneloup O, Chateil JF, Marthan R, Fayon M, Laurent F. Allergic Bronchopulmonary Aspergillosis in Cystic Fibrosis: MR Imaging of Airway Mucus Contrasts as a Tool for Diagnosis. Radiology 2017; 285:261-269. [PMID: 28530849 DOI: 10.1148/radiol.2017162350] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Purpose To assess the diagnostic accuracy of mucus contrast characterization by using magnetic resonance (MR) imaging to discriminate allergic bronchopulmonary aspergillosis (ABPA) in cystic fibrosis (CF). Materials and Methods The study was approved by the local Ethics Committee, and all patients or their parents gave written informed consent. One hundred ten consecutive patients with CF were screened between January 2014 and July 2015. All patients underwent a non-contrast material-enhanced MR protocol that included routine T1-weighted and T2-weighted sequences. The presence of mucus with both high T1 and low T2 signal intensities and the so-called inverted mucoid impaction signal (IMIS) sign was qualitatively and quantitatively assessed by two physicians who were blinded to all other data. The reference standard for a diagnosis of ABPA was the criteria of the Cystic Fibrosis Foundation Consensus Conference. ABPA status was followed up for 1 year. Reproducibility was assessed by using the κ test, correlation was assessed by using the Spearman coefficient, and diagnostic accuracy was assessed by calculating the sensitivity and specificity of IMIS. Results One hundred eight patients with CF were included (mean age, 20 years ± 11 [standard deviation]; range, 6-53 years): 18 patients with ABPA and 90 patients without ABPA. At the lobar level, inter- and intrareader reproducibility were very good (κ > 0.90). IMIS had 94% sensitivity (95% confidence interval [CI]: 73%, 99%) and 100% specificity (95% CI: 96%, 100%) for the diagnosis of ABPA. A complete resolution of IMIS was observed in patients with ABPA after 3 months of specific treatment that was significantly correlated with decrease in total immunoglobulin E level (ρ = 0.47; P = .04). Conclusion The IMIS sign was both specific and sensitive for the diagnosis of ABPA in CF. Allergic fungal inflammation appears to induce characteristic modifications of mucus contrasts that are assessable by using a noninvasive, contrast material-free, and radiation-free method. © RSNA, 2017 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Gaël Dournes
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Patrick Berger
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - John Refait
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Julie Macey
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Stephanie Bui
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Laurence Delhaes
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Michel Montaudon
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Olivier Corneloup
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Jean-François Chateil
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Roger Marthan
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - Michaël Fayon
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| | - François Laurent
- From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.B., L.D., M.M., J.F.C., R.M., M.F., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, CIC 1401, F-33000, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.B., L.D., M.M., R.M., M.F., F.L.); Thoracic and Cardiovascular Imaging Service, Service for Respiratory Diseases, Service for Exploration of Respiratory Function, CHU of Bordeaux, Pessac, France (G.D., P.B., J.R., J.M., M.M., O.C., R.M., F.L.); and Service for Imaging in Women and Children, Pediatric Pneumonology Unit, Laboratory of Parasitology-Mycology, CHU of Bordeaux, Bordeaux, France (S.B., L.D., J.F.C., M.F.)
| |
Collapse
|
23
|
Hou H, Khan N, Gohain S, Eskey CJ, Moodie KL, Maurer KJ, Swartz HM, Kuppusamy P. Dynamic EPR Oximetry of Changes in Intracerebral Oxygen Tension During Induced Thromboembolism. Cell Biochem Biophys 2017; 75:285-294. [PMID: 28434138 DOI: 10.1007/s12013-017-0798-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 04/12/2017] [Indexed: 12/19/2022]
Abstract
Cerebral tissue oxygenation (oxygen tension, pO2) is a critical parameter that is closely linked to brain metabolism, function, and pathophysiology. In this work, we have used electron paramagnetic resonance oximetry with a deep-tissue multi-site oxygen-sensing probe, called implantable resonator, to monitor temporal changes in cerebral pO2 simultaneously at four sites in a rabbit model of ischemic stroke induced by embolic clot. The pO2 values in healthy brain were not significantly different among the four sites measured over a period of 4 weeks. During exposure to 15% O2 (hypoxia), a sudden and significant decrease in pO2 was observed in all four sites. On the other hand, brief exposure to breathing carbogen gas (95% O2 + 5% CO2) showed a significant increase in the cerebral pO2 from baseline value. During ischemic stroke, induced by embolic clot in the left brain, a significant decline in the pO2 of the left cortex (ischemic core) was observed without any change in the contralateral sites. While the pO2 in the non-infarct regions returned to baseline at 24-h post-stroke, pO2 in the infarct core was consistently lower compared to the baseline and other regions of the brain. The results demonstrated that electron paramagnetic resonance oximetry with the implantable resonator can repeatedly and simultaneously report temporal changes in cerebral pO2 at multiple sites. This oximetry approach can be used to develop interventions to rescue hypoxic/ischemic tissue by modulating cerebral pO2 during hypoxic and stroke injury.
Collapse
Affiliation(s)
- Huagang Hou
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Nadeem Khan
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Sangeeta Gohain
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Clifford J Eskey
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Karen L Moodie
- Center for Comparative Medicine and Research, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Kirk J Maurer
- Center for Comparative Medicine and Research, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Harold M Swartz
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Periannan Kuppusamy
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA.
| |
Collapse
|
24
|
Jungmann PM, Agten CA, Pfirrmann CW, Sutter R. Advances in MRI around metal. J Magn Reson Imaging 2017; 46:972-991. [PMID: 28342291 DOI: 10.1002/jmri.25708] [Citation(s) in RCA: 128] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Accepted: 03/03/2017] [Indexed: 01/02/2023] Open
Abstract
The prevalence of orthopedic metal implants is continuously rising in the aging society. Particularly the number of joint replacements is increasing. Although satisfying long-term results are encountered, patients may suffer from complaints or complications during follow-up, and often undergo magnetic resonance imaging (MRI). Yet metal implants cause severe artifacts on MRI, resulting in signal-loss, signal-pileup, geometric distortion, and failure of fat suppression. In order to allow for adequate treatment decisions, metal artifact reduction sequences (MARS) are essential for proper radiological evaluation of postoperative findings in these patients. During recent years, developments of musculoskeletal imaging have addressed this particular technical challenge of postoperative MRI around metal. Besides implant material composition, configuration and location, selection of appropriate MRI hardware, sequences, and parameters influence artifact genesis and reduction. Application of dedicated metal artifact reduction techniques including high bandwidth optimization, view angle tilting (VAT), and the multispectral imaging techniques multiacquisition variable-resonance image combination (MAVRIC) and slice-encoding for metal artifact correction (SEMAC) may significantly reduce metal-induced artifacts, although at the expense of signal-to-noise ratio and/or acquisition time. Adding advanced image acquisition techniques such as parallel imaging, partial Fourier transformation, and advanced reconstruction techniques such as compressed sensing further improves MARS imaging in a clinically feasible scan time. This review focuses on current clinically applicable MARS techniques. Understanding of the main principles and techniques including their limitations allows a considerate application of these techniques in clinical practice. Essential orthopedic metal implants and postoperative MR findings around metal are presented and highlighted with clinical examples. LEVEL OF EVIDENCE 4 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017;46:972-991.
Collapse
Affiliation(s)
- Pia M Jungmann
- Department of Radiology, Balgrist University Hospital, Zurich, Switzerland.,Faculty of Medicine, University of Zurich, Zurich, Switzerland.,Department of Radiology, Technical University of Munich, Munich, Germany
| | - Christoph A Agten
- Department of Radiology, Balgrist University Hospital, Zurich, Switzerland.,Faculty of Medicine, University of Zurich, Zurich, Switzerland
| | - Christian W Pfirrmann
- Department of Radiology, Balgrist University Hospital, Zurich, Switzerland.,Department of Radiology, Technical University of Munich, Munich, Germany
| | - Reto Sutter
- Department of Radiology, Balgrist University Hospital, Zurich, Switzerland.,Department of Radiology, Technical University of Munich, Munich, Germany
| |
Collapse
|
25
|
Acute Ataxia in Children: A Review of the Differential Diagnosis and Evaluation in the Emergency Department. Pediatr Neurol 2016; 65:14-30. [PMID: 27789117 DOI: 10.1016/j.pediatrneurol.2016.08.025] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2015] [Accepted: 08/26/2016] [Indexed: 11/21/2022]
Abstract
Acute ataxia in a pediatric patient poses a diagnostic dilemma for any physician. While the most common etiologies are benign, occasional individuals require urgent intervention. Children with stroke, toxic ingestion, infection, and neuro-inflammatory disorders frequently exhibit ataxia as an essential-if not the only-presenting feature. The available retrospective research utilize inconsistent definitions of acute ataxia, precluding the ability to pool data from these studies. No prospective data exist that report on patients presenting to the emergency department with ataxia. This review examines the reported causes of ataxia and attempts to group them into distinct categories: post-infectious and inflammatory central and peripheral phenomena, toxic ingestion, neurovascular, infectious and miscellaneous. From there, we synthesize the existing literature to understand which aspects of the history, physical exam, and ancillary testing might aid in narrowing the differential diagnosis. MRI is superior to CT in detecting inflammatory or vascular insults in the posterior fossa, though CT may be necessary in emergent situations. Lumbar puncture may be deferred until after admission in most instances, with suspicion for meningitis being the major exception. There is insufficient evidence to guide laboratory evaluation of serum, testing should be ordered based on clinical judgement-recommended studies include metabolic profiles and screening labs for metabolic disorders (lactate and ammonia). All patients should be reflexively screened for toxic ingestions.
Collapse
|
26
|
18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging. Invest Radiol 2016; 51:163-9. [PMID: 26784400 PMCID: PMC4747979 DOI: 10.1097/rli.0000000000000218] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Objectives The aim of this study was to compare 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to 18F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Materials and Methods Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board–approved study. After a single 18F-FDG injection, patients consecutively underwent 18F-FDG PET⁄CT and 18F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on 18F-FDG PET/CT and 18F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Results Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for 18F-FDG PET/CT, 18F-FDG PET/MR, and 18F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. 18F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and 18F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between 18F-FDG PET/MR DWI and 18F-FDG PET/CT, 99.2% (κ, 0.96) between 18F-FDG PET/MR and 18F-FDG PET/CT, and 99.4% (κ, 0.97) between 18F-FDG PET/MR DWI and 18F-FDG PET/MR. There was a strong correlation between 18F-FDG PET/CT and 18F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax (18F-FDG PET/CT: r = 0.46, P = 0.65; 18F-FDG PET/MR: r = 0.64, P = 0.53) or between ADCmean and SUVmean (respectively, r = −0.14, P = 0.17 for the correlation with PET/CT and r = −0.14, P = 0.14 for the correlation with PET/MR). Conclusions 18F-FDG PET/MR and 18F-FDG PET/CT show a similar diagnostic performance in lymphoma patients. However, if DWI is included in the 18F-FDG PET/MR protocol, results surpass those of 18F-FDG PET/CT because of the higher sensitivity of DWI for mucosa-associated lymphoid tissue lymphomas.
Collapse
|
27
|
Three-Dimensional CAIPIRINHA SPACE TSE for 5-Minute High-Resolution MRI of the Knee. Invest Radiol 2016; 51:609-17. [DOI: 10.1097/rli.0000000000000287] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
28
|
Schulz A, Viktil E, Godt JC, Johansen CK, Dormagen JB, Holtedahl JE, Labori KJ, Bach-Gansmo T, Kløw NE. Diagnostic performance of CT, MRI and PET/CT in patients with suspected colorectal liver metastases: the superiority of MRI. Acta Radiol 2016; 57:1040-8. [PMID: 26622057 DOI: 10.1177/0284185115617349] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Accepted: 10/21/2015] [Indexed: 12/12/2022]
Abstract
BACKGROUND Meticulous imaging of colorectal liver metastases (CRLM) is mandatory to optimize outcome after liver resection. However, the detection of CRLM is still challenging. PURPOSE To evaluate prospectively if magnetic resonance imaging (MRI) with diffusion-weighted and Gd-EOB-DTPA-enhanced sequences had a better diagnostic performance for CRLM compared to computed tomography (CT) and fluorine-18 fluorodeoxyglucose positron emission tomography (PET/CT). MATERIAL AND METHODS Forty-six patients scheduled for resection of suspected CRLM were evaluated prospectively from September 2011 to January 2013. None of the patients had undergone previous treatment for their CRLM. Multiphase CT, liver MRI with diffusion-weighted and dynamic Gd-EOB-DTPA-enhanced sequences and low-dose PET/CT were performed. Two independent, blinded readers evaluated the examinations. The reference standard was histopathological confirmation (81/140 CRLM) or follow-up. RESULTS A total of 140 CRLM and 196 benign lesions were identified. On a per-lesion basis, MRI had the significantly highest sensitivity overall and for CRLM < 10 mm (P < 0.001). Overall sensitivity/specificity and PPV/NPV were 68%/94% and 89%/81% for CT, 90%/87% and 82%/93% for MRI, and 61%/99% and 97%/78% for PET/CT. For CRLM < 10 mm it was 16%/96% and 54%/80% for CT, 74%/88% and 64%/93% for MRI, and 9%/98% and 57%/79% for PET/CT. CONCLUSION MRI had the significantly highest sensitivity compared with CT and PET/CT, particularly for CRLM < 10 mm. Therefore, detection of CRLM should be based on MRI.
Collapse
Affiliation(s)
- Anselm Schulz
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Ellen Viktil
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Johannes Clemens Godt
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Cathrine K Johansen
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | | | | | - Knut Jørgen Labori
- Department of Hepato-Pancreato-Biliary Surgery, Oslo University Hospital, Oslo, Norway
| | - Tore Bach-Gansmo
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Nils-Einar Kløw
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
29
|
Fritz J, Raithel E, Thawait GK, Gilson W, Papp DF. Six-Fold Acceleration of High-Spatial Resolution 3D SPACE MRI of the Knee Through Incoherent k-Space Undersampling and Iterative Reconstruction—First Experience. Invest Radiol 2016; 51:400-9. [DOI: 10.1097/rli.0000000000000240] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
30
|
Radiology resident MR and CT image analysis skill assessment using an interactive volumetric simulation tool - the RadioLOG project. Eur Radiol 2016; 27:878-887. [PMID: 27165134 DOI: 10.1007/s00330-016-4384-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 04/01/2016] [Accepted: 04/25/2016] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Assess the use of a volumetric simulation tool for the evaluation of radiology resident MR and CT interpretation skills. MATERIAL AND METHODS Forty-three participants were evaluated with a software allowing the visualisation of multiple volumetric image series. There were 7 medical students, 28 residents and 8 senior radiologists among the participants. Residents were divided into two sub-groups (novice and advanced). The test was composed of 15 exercises on general radiology and lasted 45 min. Participants answered a questionnaire on their experience with the test using a 5-point Likert scale. This study was approved by the dean of the medical school and did not require ethics committee approval. RESULTS The reliability of the test was good with a Cronbach alpha value of 0.9. Test scores were significantly different in all sub-groups studies (p < 0.0225). The relation between test scores and the year of residency was logarithmic (R2 = 0.974). Participants agreed that the test reflected their radiological practice (3.9 ± 0.9 on a 5-point scale) and was better than the conventional evaluation methods (4.6 ± 0.5 on a 5-point scale). CONCLUSION This software provides a high quality evaluation tool for the assessment of the interpretation skills in radiology residents. KEY POINTS • This tool allows volumetric image analysis of MR and CT studies. • A high reliability test could be created with this tool. • Test scores were strongly associated with the examinee expertise level. • Examinees positively evaluated the authenticity and usability of this tool.
Collapse
|
31
|
Sultana A, Jackson R, Tim G, Bostock E, Psarelli EE, Cox TF, Sutton R, Ghaneh P, Raraty MGT, Neoptolemos JP, Halloran CM. What Is the Best Way to Identify Malignant Transformation Within Pancreatic IPMN: A Systematic Review and Meta-Analyses. Clin Transl Gastroenterol 2015; 6:e130. [PMID: 26658837 PMCID: PMC4816095 DOI: 10.1038/ctg.2015.60] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Accepted: 11/03/2015] [Indexed: 12/17/2022] Open
Abstract
OBJECTIVES Pancreatic intraductal papillary mucinous neoplasias (IPMNs) represent 25% of all cystic neoplasms and are precursor lesions for pancreatic ductal adenocarcinoma. This study aims to identify the best imaging modality for detecting malignant transformation in IPMN, the sensitivity and specificity of risk features on imaging, and the usefulness of tumor markers in serum and cyst fluid to predict malignancy in IPMN. METHODS Databases were searched from November 2006 to March 2014. Pooled sensitivity and specificity of diagnostic techniques/imaging features of suspected malignancy in IPMN using a hierarchical summary receiver operator characteristic (HSROC) approach were performed. RESULTS A total of 467 eligible studies were identified, of which 51 studies met the inclusion criteria and 37 of these were incorporated into meta-analyses. The pooled sensitivity and specificity for risk features predictive of malignancy on computed tomography/magnetic resonance imaging were 0.809 and 0.762 respectively, and on positron emission tomography were 0.968 and 0.911. Mural nodule, cyst size, and main pancreatic duct dilation found on imaging had pooled sensitivity for prediction of malignancy of 0.690, 0.682, and 0.614, respectively, and specificity of 0.798, 0.574, and 0.687. Raised serum carbohydrate antigen 19-9 (CA19-9) levels yielded sensitivity of 0.380 and specificity of 0903. Combining parameters yielded a sensitivity of 0.743 and specificity of 0.906. CONCLUSIONS PET holds the most promise in identifying malignant transformation within an IPMN. Combining parameters increases sensitivity and specificity; the presence of mural nodule on imaging was the most sensitive whereas raised serum CA19-9 (>37 KU/l) was the most specific feature predictive of malignancy in IPMNs.
Collapse
Affiliation(s)
- Asma Sultana
- NIHR Pancreas Biomedical Research Unit, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| | - Richard Jackson
- Medical Statistics, CRUK Liverpool Cancer Trials Unit, University of Liverpool, Liverpool, UK
| | - Gilbert Tim
- NIHR Pancreas Biomedical Research Unit, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| | - Emma Bostock
- NIHR Pancreas Biomedical Research Unit, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| | - Eftychia E Psarelli
- Medical Statistics, CRUK Liverpool Cancer Trials Unit, University of Liverpool, Liverpool, UK
| | - Trevor F Cox
- Medical Statistics, CRUK Liverpool Cancer Trials Unit, University of Liverpool, Liverpool, UK
| | - Robert Sutton
- NIHR Pancreas Biomedical Research Unit, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| | - Paula Ghaneh
- NIHR Pancreas Biomedical Research Unit, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| | - Michael G T Raraty
- NIHR Pancreas Biomedical Research Unit, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| | - John P Neoptolemos
- NIHR Pancreas Biomedical Research Unit, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| | - Christopher M Halloran
- NIHR Pancreas Biomedical Research Unit, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, Liverpool, UK
| |
Collapse
|
32
|
Improved detection of inflammatory bowel disease by additional automated motility analysis in magnetic resonance imaging. Invest Radiol 2015; 50:67-72. [PMID: 25260093 DOI: 10.1097/rli.0000000000000097] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVES The objective of this study was to evaluate whether the use of automatically generated maps of bowel motility (motility mapping) in magnetic resonance imaging (MRI) leads to an increased detection rate of inflammatory bowel disease. MATERIALS AND METHODS Fifty consecutive patients with suspected or known inflammatory bowel disease who underwent bowel MRI using a 1.5-T scanner were analyzed retrospectively. In addition to standard small bowel magnetic resonance protocol, a dynamic coronal T2-weighted sequence (dynamic MRI) was acquired. Dynamic sequences were used to automatically generate a parametric map depicting bowel motility. Two readings of the MRI were performed: first, evaluation of static MRI alone and second, evaluation of static MRI combined with dynamic MRI (motility mapping). Static MRI was analyzed on parameters defining inflammation (morphology, enhancement). Dynamic MRI (motility mapping) was evaluated on the basis of a color-coded scheme displaying hypomotility and hypermotility. RESULTS Using motility maps, additional inflammatory lesions were found in 13 (26%) of the 50 patients, resulting in a significantly higher detection rate using static MRI together with motility mapping compared with static MRI alone (P = 0.0002). Overall, 66 inflammatory lesions of the bowel were detected in a total of 38 patients (static MRI + motility mapping) versus 51 lesions in 34 patients (sole evaluation of static MRI). CONCLUSIONS Motility assessment of the bowel provides additional information and improves the detection of inflammatory lesions in MRI.
Collapse
|
33
|
Semework M. A Customizable Multimodality Imaging Compound That Relates External Landmarks to Internal Structures. J Nucl Med Technol 2015; 43:267-74. [PMID: 26338487 DOI: 10.2967/jnmt.115.162404] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2015] [Accepted: 08/11/2015] [Indexed: 12/25/2022] Open
Abstract
UNLABELLED Numerous research and clinical interventions, such as targeting drug deliveries or surgeries and finding blood clots, abscesses, or lesions, require accurate localization of various body parts. Individual differences in anatomy make it hard to use typical stereotactic procedures that rely on external landmarks and standardized atlases. For instance, it is not unusual to incorrectly place a craniotomy in brain surgery. This project was thus performed to find a new and easy method to correctly establish the relationship between external landmarks and medical scans of internal organs, such as specific regions of the brain. METHODS This paper introduces an MRI, CT, and radiographically visible compound that can be applied to any surface and therefore provide an external reference point to an internal (eye-invisible) structure. RESULTS Tested on nonhuman primates and isolated brain scans, this compound showed up with the same color in different scan types, making practical work possible. Conventional, and mostly of specific utility, products such as contrast agents were differentially colored or completely failed to show up and were not flexible. CONCLUSION This compound can be customized to have different viscosities, colors, odors, and other characteristics. It can also be mixed with hardening materials such as acrylic for industrial or engineering uses, for example. Laparoscopy wands, electroencephalogram leads, and other equipment could also be embedded with or surrounded by the compound for ease in 3-dimensional visualizations. A pending U.S. patent endorses this invention.
Collapse
|
34
|
McDonald RJ, Schwartz KM, Eckel LJ, Diehn FE, Hunt CH, Bartholmai BJ, Erickson BJ, Kallmes DF. The effects of changes in utilization and technological advancements of cross-sectional imaging on radiologist workload. Acad Radiol 2015. [PMID: 26210525 DOI: 10.1016/j.acra.2015.05.007] [Citation(s) in RCA: 233] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
RATIONALE AND OBJECTIVES To examine the effect of changes in utilization and advances in cross-sectional imaging on radiologists' workload. MATERIALS AND METHODS All computed tomography (CT) and magnetic resonance imaging (MRI) examinations performed at a single institution between 1999 and 2010 were identified and associated with the total number of images for each examination. Annual trends in institutional numbers of interpreted examinations and images were translated to changes in daily workload for the individual radiologist by normalizing to the number of dedicated daily CT and MRI work assignments, assuming a 255-day/8-hour work day schedule. Temporal changes in institutional and individual workload were assessed by Sen's slope analysis (Q = median slope) and Mann-Kendall test (Z = Z statistic). RESULTS From 1999 to 2010, a total of 1,517,149 cross-sectional imaging studies (CT = 994,471; MRI = 522,678) comprising 539,210,581 images (CT = 339,830,947; MRI = 199,379,634) were evaluated at our institution. Total annual cross-sectional studies steadily increased from 84,409 in 1999 to 147,336 in 2010, representing a twofold increase in workload (Q = 6465/year, Z = 4.2, P < .0001). Concomitantly, the number of annual departmental cross-sectional images interpreted increased from 9,294,140 in 1990 to 94,271,551 in 2010, representing a 10-fold increase (Q = 8707876/year, Z = 4.5, P < .0001). Adjusting for staffing changes, the number of images requiring interpretation per minute of every workday per staff radiologist increased from 2.9 in 1999 to 16.1 in 2010 (Q = 1.7/year, Z = 4.3, P < .0001). CONCLUSIONS Imaging volumes have grown at a disproportionate rate to imaging utilization increases at our institution. The average radiologist interpreting CT or MRI examinations must now interpret one image every 3-4 seconds in an 8-hour workday to meet workload demands.
Collapse
|
35
|
Lukacs S, Vale J, Mazaris E. Difference between actual vs. pathology prostate weight in TURP and radical robotic-assisted prostatectomy specimen. Int Braz J Urol 2015; 40:823-7. [PMID: 25615251 DOI: 10.1590/s1677-5538.ibju.2014.06.14] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2014] [Accepted: 05/14/2014] [Indexed: 11/21/2022] Open
Abstract
INTRODUCTION To investigate and highlight the effect of formaldehyde induced weight reduction in transurethral resection of prostate (TURP) and radical robotically-assisted prostatectomy (RALP) specimen as a result of standard chemical fixation. MATERIALS AND METHODS 51 patients were recruited from January 2013 to June 2013 who either underwent a TURP (n=26) or RALP (n=25). Data was collected prospectively by the operating surgeon who measured the native, unfixed histology specimen directly after operation. The specimens were fixed in 10% Formaldehyde Solution BP and sent to the pathology laboratory where after sufficient fixation period was re-weighed. RESULTS Overall mean age 64.78 years, TURP mean age 68.31 years RALP mean age 61.12 years. We found that the overall prostatic specimen (n=51) weight loss after fixation was a mean of 11.20% (3.78 grams) (p ≤ 0.0001). Subgroup analysis of the native TURP chips mean weight was 16.15 grams and formalin treated mean weight was 14.00 grams (p ≤ 0.0001). Therefore, TURP chips had a mean of 13.32 % (2.15 grams) weight loss during chemical fixation. RALP subgroup unfixed specimen mean weight was 52.08 grams and formalin treated mean weight was 42.60 grams (p ≤ 0.0001), a 19.32 % (9.48 grams) mean weight reduction. CONCLUSION It has not been known that prostatic chips and whole human radical prostatectomy specimen undergo a significant weight reduction. The practical significance of the accurate prostate weight in patient management may be limited, however, it is agreed that this should be recorded correctly, as data is potential interest for research purposes and vital for precise documentation.
Collapse
Affiliation(s)
- Szilveszter Lukacs
- St Mary's Hospital Imperial College Healthcare NHS Trust, Praed Street, London, W2 1NY, United Kingdom
| | - Justin Vale
- St Mary's Hospital Imperial College Healthcare NHS Trust, Praed Street, London, W2 1NY, United Kingdom
| | - Evangelos Mazaris
- St Mary's Hospital Imperial College Healthcare NHS Trust, Praed Street, London, W2 1NY, United Kingdom
| |
Collapse
|
36
|
CAIPIRINHA-VIBE and GRAPPA-VIBE for liver MRI at 1.5 T: a comparative in vivo patient study. J Comput Assist Tomogr 2015; 39:263-9. [PMID: 25635931 DOI: 10.1097/rct.0000000000000200] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
OBJECTIVE Three-dimensional T1-weighted (T1W) gradient recall echo volumetric interpolated breath-hold examination (VIBE) using generalized autocalibrating partially parallel acquisitions (GRAPPA) is one of the key sequences in liver magnetic resonance imaging (MRI) and is used for precontrast, dynamic postcontrast, and delayed postcontrast imaging. The purpose of this study is to compare image quality and liver lesion detection (LLD) on a shorter-duration T1W VIBE sequence using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique with the conventional T1W GRAPPA-VIBE sequence during a single liver MRI session on a 1.5-T Seimens scanner. METHODS Twenty consecutive patients (9 women and 11 men; age range, 36-85 years) were included in this prospective study. All patients underwent a complete liver MRI on a 1.5-T magnet (Aera; Siemens Medical Systems, Erlangen, Germany) that consisted of a T1W (in/out-of-phase), T2W, DWI, and precontrast and postcontrast multiphasic images (late arterial, 50 seconds, 120 seconds, and 300 seconds) with GRAPPA-VIBE. The CAIPI-VIBE images were acquired for precontrast and at 300 seconds (5 minutes) postcontrast phases (6.9 seconds per phase) in addition to GRAPPA-VIBE (21 seconds per phase). The shorter time for the CAIPI-VIBE was selected to allow postprocessing of image acquisition in the setting of multi-late arterial phase (single breath hold) postcontrast images. Five radiologists independently analyzed image quality with predefined scores for liver edge sharpness, artifacts, fat saturation deficiency, visualization of the portal veins and hepatic veins, and LLD (size, <0.5-3.8 cm). Score 0 was suboptimal (inadequate), 1 was acceptable for diagnosis, and 2 was optimal (excellent). Kappa statistics were used to assess agreement among readers. Generalized linear mixed model with generalized estimation equation method was used to estimate and compare the LLD failure rates. RESULTS No statistically significant difference was seen in the degree of reader variability between CAIPI-VIBE and GRAPPA-VIBE for all evaluated categories using multirater κ statistics. For the precontrast and 5-minutepostcontrast phase sequences, greater than 95% of images were considered to be of acceptable quality in all image quality categories for both sequences. Forty-one lesions were evaluated in 17 patients with total of 204 observations (n = 204) by 5 readers. For 5-minute postcontrast images, the LLD rate of CAIPI-VIBE (80%) was lower than GRAPPA-VIBE (84%) (P = 0.03) for small lesions (0.5-1.7 cm). There was no significant difference in lesion detection on precontrast images. CONCLUSIONS At 1.5 T, the CAIPI-VIBE may be helpful in reducing scan time and demonstrates similar image quality compared with the traditional GRAPPA-VIBE. The CAIPI-VIBE has shorter breath-hold time requirement and thus can be an acceptable alternative for the precontrast and 5-minute postcontrast GRAPPA-VIBE in patients with breath-hold difficulties.
Collapse
|
37
|
Misaki M, Savitz J, Zotev V, Phillips R, Yuan H, Young KD, Drevets WC, Bodurka J. Contrast enhancement by combining T1- and T2-weighted structural brain MR Images. Magn Reson Med 2014; 74:1609-20. [PMID: 25533337 DOI: 10.1002/mrm.25560] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Revised: 11/07/2014] [Accepted: 11/09/2014] [Indexed: 11/08/2022]
Abstract
PURPOSE In order to more precisely differentiate cerebral structures in neuroimaging studies, a novel technique for enhancing the tissue contrast based on a combination of T1-weighted (T1w) and T2-weighted (T2w) MRI images was developed. METHODS The combined image (CI) was calculated as CI = (T1w - sT2w)/(T1w + sT2w), where sT2w is the scaled T2-weighted image. The scaling factor was calculated to adjust the gray- matter (GM) voxel intensities in the T2w image so that their median value equaled that of the GM voxel intensities in the T1w image. The image intensity homogeneity within a tissue and the discriminability between tissues in the CI versus the separate T1w and T2w images were evaluated using the segmentation by the FMRIB Software Library (FSL) and FreeSurfer (Athinoula A. Martinos Center for Biomedical Imaging at Massachusetts General Hospital, Boston, MA) software. RESULTS The combined image significantly improved homogeneity in the white matter (WM) and GM compared to the T1w images alone. The discriminability between WM and GM also improved significantly by applying the CI approach. Significant enhancements to the homogeneity and discriminability also were achieved in most subcortical nuclei tested, with the exception of the amygdala and the thalamus. CONCLUSION The tissue discriminability enhancement offered by the CI potentially enables more accurate neuromorphometric analyses of brain structures.
Collapse
Affiliation(s)
- Masaya Misaki
- Laureate Institute for Brain Research, Tulsa, Oklahoma, USA
| | - Jonathan Savitz
- Laureate Institute for Brain Research, Tulsa, Oklahoma, USA.,Faculty of Community Medicine, University of Tulsa, Tulsa, Oklahoma, USA
| | - Vadim Zotev
- Laureate Institute for Brain Research, Tulsa, Oklahoma, USA
| | | | - Han Yuan
- Laureate Institute for Brain Research, Tulsa, Oklahoma, USA
| | | | - Wayne C Drevets
- Laureate Institute for Brain Research, Tulsa, Oklahoma, USA.,Janssen Pharmaceuticals, LCC, of Johnson & Johnson, Inc., Titusville, New Jersey, USA
| | - Jerzy Bodurka
- Laureate Institute for Brain Research, Tulsa, Oklahoma, USA.,College of Engineering, University of Oklahoma, Tulsa, Oklahoma, USA
| |
Collapse
|
38
|
Van Schouwenburg F, Ackermann C, Pitcher R. An audit of elective outpatient magnetic resonance imaging in a tertiary South African public-sector hospital. SA J Radiol 2014. [DOI: 10.4102/sajr.v18i1.689] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
Background: Increasing demand for magnetic resonance imaging (MRI) has resulted in longer waiting times for elective MRI, particularly in resource-limited healthcare environments.However, inappropriate imaging requests may also contribute to prolonged MRI waiting times. At the time of the present study, the waiting time for elective MRI studies at Tygerberg Hospital (TBH), a tertiary-level public-sector healthcare facility in Cape Town (South Africa),was 24 weeks.Objectives: To document the nature and clinical appropriateness of scheduled TBH outpatient MRI examinations.Method: A retrospective analysis of the referral forms of all elective outpatient MRIexaminations scheduled at TBH from 01 June to 30 November 2011 was conducted. Patient age, gender, clinical details, provisional diagnosis, examination requested and referring clinician were recorded on a customised data sheet. Two radiologists independently evaluated the appropriateness of each request by comparing the clinical details and the provisional diagnosis provided with the 2012 American College of Radiology (ACR) guidelines for the appropriate use of MRI.Results: Four hundred and sixty-six patients (median age 42 years; interquartile range 19–55) who had 561 examinations were scheduled in the review period; 70 (15%) were children less than 6 years old. Neurosurgery (n = 164; 35%), orthopaedic (n = 144; 31%),neurology (n = 53; 11%) and paediatric (n = 27; 6%) outpatients accounted for the majority(81%) of referrals; 464 (99.6%) were from specialist clinics. MRIs of the spine (n = 314; 56%),brain (n = 152; 27%) and musculoskeletal system (n = 70, 13%) accounted for more than 95%of the investigations. In 455 cases (98%), the referral was congruent with published ACR guidelines for appropriate MRI utilisation.Conclusion: Scheduled outpatient MRI examinations at TBH reflect optimal clinical use of a limited resource. MRI utilisation is largely confined to traditional neuro-imaging. Any initiative to decrease the elective MRI waiting time should focus on service expansion.
Collapse
|
39
|
Toy R, Bauer L, Hoimes C, Ghaghada KB, Karathanasis E. Targeted nanotechnology for cancer imaging. Adv Drug Deliv Rev 2014; 76:79-97. [PMID: 25116445 PMCID: PMC4169743 DOI: 10.1016/j.addr.2014.08.002] [Citation(s) in RCA: 112] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2014] [Revised: 07/26/2014] [Accepted: 08/04/2014] [Indexed: 02/02/2023]
Abstract
Targeted nanoparticle imaging agents provide many benefits and new opportunities to facilitate accurate diagnosis of cancer and significantly impact patient outcome. Due to the highly engineerable nature of nanotechnology, targeted nanoparticles exhibit significant advantages including increased contrast sensitivity, binding avidity and targeting specificity. Considering the various nanoparticle designs and their adjustable ability to target a specific site and generate detectable signals, nanoparticles can be optimally designed in terms of biophysical interactions (i.e., intravascular and interstitial transport) and biochemical interactions (i.e., targeting avidity towards cancer-related biomarkers) for site-specific detection of very distinct microenvironments. This review seeks to illustrate that the design of a nanoparticle dictates its in vivo journey and targeting of hard-to-reach cancer sites, facilitating early and accurate diagnosis and interrogation of the most aggressive forms of cancer. We will report various targeted nanoparticles for cancer imaging using X-ray computed tomography, ultrasound, magnetic resonance imaging, nuclear imaging and optical imaging. Finally, to realize the full potential of targeted nanotechnology for cancer imaging, we will describe the challenges and opportunities for the clinical translation and widespread adaptation of targeted nanoparticles imaging agents.
Collapse
Affiliation(s)
- Randall Toy
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA; Case Center for Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Lisa Bauer
- Case Center for Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA; Department of Physics, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Christopher Hoimes
- Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106, USA; University Hospitals Case Medical Center, Cleveland, OH 44106, USA
| | - Ketan B Ghaghada
- Edward B. Singleton Department of Pediatric Radiology, Texas Children's Hospital, Houston, TX 77030, USA; Department of Radiology, Baylor College of Medicine, Houston, TX 77030, USA
| | - Efstathios Karathanasis
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA; Case Center for Imaging Research, Case Western Reserve University, Cleveland, OH 44106, USA; Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106, USA; Department of Radiology, Case Western Reserve University, Cleveland, OH 44106, USA.
| |
Collapse
|
40
|
Bharucha AE, Karwoski RA, Fidler J, Holmes DR, Robb RA, Riederer SJ, Zinsmeister AR. Comparison of manual and semiautomated techniques for analyzing gastric volumes with MRI in humans. Am J Physiol Gastrointest Liver Physiol 2014; 307:G582-7. [PMID: 25012844 PMCID: PMC4182289 DOI: 10.1152/ajpgi.00048.2014] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Gastric emptying, accommodation, and motility can be quantified with magnetic resonance imaging (MRI). The first step in image analysis entails segmenting the stomach from surrounding structures, usually by a time-consuming manual process. We have developed a semiautomated process to segment and measure gastric volumes with MRI. Gastric images were acquired with a three-dimensional gradient echo MRI sequence at 5, 10, 20, and 30 min after ingestion of a liquid nutrient (Ensure, 296 ml) labeled with gadolinium in 20 healthy volunteers and 29 patients with dyspeptic symptoms. The agreement between gastric volumes measured by manual segmentation and our new semiautomated algorithm was assessed with Lin's concordance correlation coefficient (CCC) and the Bland Altman test. At 5 min after a meal, food volumes measured by manual (352 ± 4 ml) and semiautomated (346 ± 4 ml) techniques were correlated {CCC[95% confidence interval (CI)] 0.70 (0.52, 0.81)}; air volumes measured by manual (88 ± 6 ml) and semiautomated (84 ± 6 ml) techniques were also correlated [CCC (95% CI) 0.89 (0.82, 0.94)]. Findings were similar at subsequent time points. The Bland Altman test was not significant. The time required for semiautomated segmentation ranged from an average of 204 s for the 5-min images to 233 s for the 20-min images. These times were appreciably smaller than the typical times of many tens of minutes, even hours, required for manual segmentation. To conclude, a semiautomated process can measure gastric food and air volume using MRI with comparable accuracy and far better efficiency than a manual process.
Collapse
Affiliation(s)
- Adil E. Bharucha
- 1Division of Gastroenterology and Hepatology, Clinical Enteric Neuroscience Translational and Epidemiological Research Program, College of Medicine, Mayo Clinic, Rochester, Minnesota;
| | - Ronald A. Karwoski
- 2Biomedical Imaging Resource, College of Medicine, Mayo Clinic, Rochester, Minnesota;
| | - Jeff Fidler
- 3Department of Radiology, College of Medicine, Mayo Clinic, Rochester, Minnesota;
| | - David R. Holmes
- 2Biomedical Imaging Resource, College of Medicine, Mayo Clinic, Rochester, Minnesota;
| | - Richard A. Robb
- 2Biomedical Imaging Resource, College of Medicine, Mayo Clinic, Rochester, Minnesota;
| | - Stephen J. Riederer
- 4MR Research Laboratory, College of Medicine, Mayo Clinic, Rochester, Minnesota; and
| | - Alan R. Zinsmeister
- 5Division of Biostatistics, College of Medicine, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
41
|
Azzabi F, Rottmar M, Jovaisaite V, Rudin M, Sulser T, Boss A, Eberli D. Viability, differentiation capacity, and detectability of super-paramagnetic iron oxide-labeled muscle precursor cells for magnetic-resonance imaging. Tissue Eng Part C Methods 2014; 21:182-91. [PMID: 24988198 DOI: 10.1089/ten.tec.2014.0110] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
Cell therapies are a promising approach for the treatment of a variety of human conditions including stress urinary incontinence, but their success greatly depends on the biodistribution, migration, survival, and differentiation of the transplanted cells. Noninvasive in vivo cell tracking therefore presents an important aspect for translation of such a procedure into the clinics. Upon labeling with superparamagnetic iron oxide (SPIO) nanoparticles, cells can be tracked by magnetic resonance imaging (MRI), but possible adverse effect of the labeling have to be considered when labeling stem cells with SPIOs. In this study, human muscle precursor cells (hMPC) were labeled with increasing concentrations of SPIO nanoparticles (100-1600 μg/mL) and cell viability and differentiation capacity upon labeling was assessed in vitro. While a linear dependence between cell viability and nanoparticle concentration could be observed, differentiation capacity was not affected by the presence of SPIOs. Using a nude mouse model, a concentration (400 μg/mL) could be defined that allows reliable detection of hMPCs by MRI but does not influence myogenic in vivo differentiation to mature and functional muscle tissue. This suggests that such an approach can be safely used in a clinical setting to track muscle regeneration in patients undergoing cell therapy without negative effects on the functionality of the bioengineered muscle.
Collapse
Affiliation(s)
- Fahd Azzabi
- 1 Division of Urology, University Hospital Zurich , Zurich, Switzerland
| | | | | | | | | | | | | |
Collapse
|
42
|
Reiss-Zimmermann M, Streitberger KJ, Sack I, Braun J, Arlt F, Fritzsch D, Hoffmann KT. High Resolution Imaging of Viscoelastic Properties of Intracranial Tumours by Multi-Frequency Magnetic Resonance Elastography. Clin Neuroradiol 2014; 25:371-8. [PMID: 24916129 DOI: 10.1007/s00062-014-0311-9] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Accepted: 04/29/2014] [Indexed: 12/24/2022]
Abstract
PURPOSE In recent years Magnetic Resonance Elastography (MRE) emerged into a clinically applicable imaging technique. It has been shown that MRE is capable of measuring global changes of the viscoelastic properties of cerebral tissue. The purpose of our study was to evaluate a spatially resolved three-dimensional multi-frequent MRE (3DMMRE) for assessment of the viscoelastic properties of intracranial tumours. METHODS A total of 27 patients (63 ± 13 years) were included. All examinations were performed on a 3.0 T scanner, using a modified phase-contrast echo planar imaging sequence. We used 7 vibration frequencies in the low acoustic range with a temporal resolution of 8 dynamics per wave cycle. Post-processing included multi-frequency dual elasto-visco (MDEV) inversion to generate high-resolution maps of the magnitude |G*| and the phase angle φ of the complex valued shear modulus. RESULTS The tumour entities included in this study were: glioblastoma (n = 11), anaplastic astrocytoma (n = 3), meningioma (n = 7), cerebral metastasis (n = 5) and intracerebral abscess formation (n = 1). Primary brain tumours and cerebral metastases were not distinguishable in terms of |G*| and φ. Glioblastoma presented the largest range of |G*| values and a trend was delineable that glioblastoma were slightly softer than WHO grade III tumours. In terms of φ, meningiomas were clearly distinguishable from all other entities. CONCLUSIONS In this pilot study, while analysing the viscoelastic constants of various intracranial tumour entities with an improved spatial resolution, it was possible to characterize intracranial tumours by their mechanical properties. We were able to clearly delineate meningiomas from intraaxial tumours, while for the latter group an overlap remains in viscoelastic terms.
Collapse
Affiliation(s)
- M Reiss-Zimmermann
- Department of Neuroradiology, University of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany.
| | - K-J Streitberger
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - I Sack
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - J Braun
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - F Arlt
- Department of Neurosurgery, University of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - D Fritzsch
- Department of Neuroradiology, University of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - K-T Hoffmann
- Department of Neuroradiology, University of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| |
Collapse
|