Thanos L, Mylona S, Kalioras V, Pomoni M, Batakis N. Potentially Life-Threatening Neck Abscesses: Therapeutic Management Under CT-Guided Drainage.
Cardiovasc Intervent Radiol 2005;
28:196-9. [PMID:
15719179 DOI:
10.1007/s00270-004-0003-y]
[Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE
To evaluate the effectiveness of CT-guided drainage of potentially life-threatening neck abscesses.
METHODS
Between September 2001 and December 2003, 15 patients presented to the emergency room with potentially life-threatening neck abscesses. Their clinical condition was critical due to the abscess size (larger than 3 cm in diameter; mean diameter 5.2 cm, SD 0.91 cm) and/or abscess location. A CT scan was carried out immediately to assess the lesion. At the same time, under CT guidance, an 8 Fr trocar-type pigtail catheter was inserted, in order to drain the abscess. The decision to drain percutaneously was based on a consensus between the surgical, infectious disease and radiology teams . The catheter was kept in place until drainage stopped, and a follow-up scan was performed.
RESULTS
In 14 (93%) patients, the abscess was completely drained, and in 1 (7%) case the collection was still present because of multiple internal septation. That patient was treated by surgical management. The catheter was in place for a mean of 3 days (SD 0.96 day).
CONCLUSION
Despite the fact that the number of our patients is small, CT-guided percutaneous drainage seems to be a fast, safe and highly effective low-cost method for the treatment of potentially life-threatening neck abscesses.
Collapse