1
|
Bezinover D, Zerillo J, Chadha RM, Wagener G, Blasi A, Johnson T, Pan TLT, De Marchi L. Use of Transesophageal Echocardiography for Liver Transplantation: A Global Comparison of Practice From the ILTS, SATA, and LICAGE. Transplantation 2024; 108:1570-1583. [PMID: 38383955 DOI: 10.1097/tp.0000000000004943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
BACKGROUND Anesthesiologists frequently use intraoperative transesophageal echocardiography (TEE) to aid in the diagnosis and management of hemodynamic problems during liver transplantation (LT). Although the use of TEE in US centers continues to increase, data regarding international use are lacking. METHODS This prospective, global, survey-based study evaluates international experience with TEE for LT. Responses from 252 LT (105 US and 147 non-US) centers representing 1789 anesthesiologists were analyzed. RESULTS Routine use of TEE in the United States has increased in the last 5 y (from 37% to 47%), but only 21% of non-US LT anesthesiologists use TEE routinely. Lack of training (44% US versus 70% non-US) and equipment (9% non-US versus 34% US) were cited as obstacles. Most survey participants preferred not to perform a complete cardiac examination but rather use only 6 of 11 basic views. Although non-US LT anesthesiologists more frequently had additional clinical training than their US counterparts, they had less TEE experience (13% versus 44%) and less frequently, TEE certification (22% versus 35%). Most LT anesthesiologists agreed that TEE certification is essential for proficiency. Of all respondents, 89% agreed or strongly agreed that TEE provides valuable information needed for immediate clinical decision-making, and >86% agreed or strongly agreed that that information could not be derived from other sources. CONCLUSIONS The use of TEE for LT surgery in the US LT centers is currently higher compared with non-US LT centers. This may become a standard monitoring modality during LT in the near future.
Collapse
Affiliation(s)
- Dmitri Bezinover
- Department of Anesthesiology and Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA
| | - Jeron Zerillo
- Department of Anesthesiology and Critical Care Medicine, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Ryan M Chadha
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic College of Medicine and Science, Jacksonville, FL
| | - Gebhard Wagener
- Department of Anesthesiology, College of Physicians and Surgeons of Columbia University, New York, NY
| | - Annabel Blasi
- Anesthesia Department, Hospital Clinic, IDIBAPS (Institut d´Investigacions Biomèdiques Agustí Pi i Sunyé), Barcelona. Spain
| | - Taylor Johnson
- Department of Anesthesiology and Perioperative Medicine, Pennsylvania State University, Hershey Medical Center, Hershey, PA
| | - Terry Ling Te Pan
- Department of Anaesthesia, National University Hospital, Singapore, Singapore
| | - Lorenzo De Marchi
- Department of Anesthesiology, MedStar-Georgetown University Hospital, Washington DC
| |
Collapse
|
2
|
Li Y, Jiang L, Wang L, Dou D, Feng Y. Evaluation of fluid responsiveness with dynamic superior vena cava collapsibility index in mechanically ventilated patients. Perioper Med (Lond) 2023; 12:10. [PMID: 37038231 PMCID: PMC10084688 DOI: 10.1186/s13741-023-00298-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 03/28/2023] [Indexed: 04/12/2023] Open
Abstract
BACKGROUND This study aimed to evaluate the predictive accuracy of the superior vena cava collapsibility index measured by transesophageal echocardiography and compare the index with stroke volume variation measured by FloTrac™/Vigileo™ in mechanically ventilated patients. METHODS In the prospective study, a total of 60 patients were enrolled for elective general surgery under mechanical ventilation, where all patients received 10 ml/kg of Ringer's lactate. Five kinds of related data were recorded before and after the fluid challenge, including the superior vena cava collapsibility index (SVC-CI), the ratio of E/e', cardiac index (CI), stroke volume variation (SVV), and central venous pressure (CVP). Based on the collected data after the fluid challenge, we classified the patients as responders (FR group) if their CI increased by at least 15% and the rest were non-responders (NR). RESULTS Twenty-five of 52 (48%) of the patients were responders, and 27 were non-responders (52%). The SVC-CI was higher in the responders (41.90 ± 11.48 vs 28.92 ± 9.05%, P < 0.01). SVC-CI was significantly correlated with △CI FloTrac (r = 0.568, P < 0.01). The area under the ROC curve (AUROC) of SVC-CI was 0.838 (95% CI 0.728 ~ 0.947, P < 0.01) with the optimal cutoff value of 39.4% (sensitivity 64%, specificity 92.6%). And there was no significant difference in E/e' between the two groups (P > 0.05). The best cutoff value for SVV was 12.5% (sensitivity 40%, specificity 89%) with the AUROC of 0.68 (95% CI 0.53 ~ 0.826, P < 0.05). CONCLUSIONS The SVC-CI and SVV can predict fluid responsiveness effectively in mechanically ventilated patients. And SVC-CI is superior in predicting fluid responsiveness compared with SVV. The E/e' ratio and CVP cannot predict FR effectively. TRIAL REGISTRATION Chinese clinical trial registry (ChiCTR2000034940).
Collapse
Affiliation(s)
- Yaru Li
- Department of Anesthesiology, Peking University People's Hospital, 11 Xi Zhi Men South Street, Beijing, 100044, China
| | - Luyang Jiang
- Department of Anesthesiology, Peking University People's Hospital, 11 Xi Zhi Men South Street, Beijing, 100044, China.
| | - Lu Wang
- Department of Anesthesiology, Peking University People's Hospital, 11 Xi Zhi Men South Street, Beijing, 100044, China
| | - Dou Dou
- Department of Anesthesiology, Peking University People's Hospital, 11 Xi Zhi Men South Street, Beijing, 100044, China
| | - Yi Feng
- Department of Anesthesiology, Peking University People's Hospital, 11 Xi Zhi Men South Street, Beijing, 100044, China
| |
Collapse
|
3
|
Pal N, Weitzel NS, Kertai MD. A Change of Tide or the Beginning of the End: COVID-19. Semin Cardiothorac Vasc Anesth 2021; 25:5-10. [PMID: 33554769 DOI: 10.1177/1089253221989132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Nirvik Pal
- Virginia Commonwealth University, Richmond, VA, USA
| | | | | |
Collapse
|
4
|
Chen YYK, Desai SP, Fox JA. Literature and new innovations leading to the rise and fall of the Swan-Ganz catheter. J Anesth Hist 2020; 6:21-25. [PMID: 33674026 DOI: 10.1016/j.janh.2020.12.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 02/24/2020] [Accepted: 12/26/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND In 1970, Harold James Charles Swan and William Ganz published their work on the pulmonary artery catheter (PAC or Swan-Ganz catheter). They described the successful bedside use of a flow-directed catheter to continuously evaluate the heart, and it was used extensively in the years following to care for critically ill patients. In recent decades, clinicians have reevaluated the risks and benefits of the PAC. AIM We acknowledge the contributions of Swan and Ganz and discuss literature, including randomized controlled trials, and new technology surrounding the rise and fall in use of the PAC. METHODS We performed a literature search of retrospective and prospective studies, including randomized controlled trials, and editorials to understand the history and clinical outcomes of the PAC. RESULTS In the 1980s, clinicians began to question the benefits of the PAC. In 1996 and 2003, a large observational study and randomized controlled trial, respectively, showed no clear benefits in outcome. Thereafter, use of PACs began to drop precipitously. New less and noninvasive technology can estimate cardiac output and blood pressure continuously. CONCLUSIONS Swan and Ganz contributed to the bedside understanding of the pathophysiology of the heart. The history of the rise and fall in use of the PAC parallels the literature and invention of less-invasive technology. Although the PAC has not been shown to improve clinical outcomes in large randomized controlled trials, it may still be useful in select patients. New less-invasive and noninvasive technology may ultimately replace it if literature supports it.
Collapse
Affiliation(s)
- Yun-Yun K Chen
- Department of Anaesthesia - Harvard Medical School, Brigham and Women's Hospital, Boston, MA, USA.
| | - Sukumar P Desai
- Department of Anaesthesia - Harvard Medical School, Brigham and Women's Hospital, Boston, MA, USA; Department of Anaesthesia - Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| | - John A Fox
- Department of Anaesthesia - Harvard Medical School, Brigham and Women's Hospital, Boston, MA, USA
| |
Collapse
|
5
|
Rong LQ, Kaushal M, Mauer E, Pryor KO, Kenfield M, Shore-Lesseron L, Gaudino MFL, Neuburger PJ. Two- or 3-Dimensional Echocardiography-Derived Cardiac Output Cannot Replace the Pulmonary Artery Catheter in Cardiac Surgery. J Cardiothorac Vasc Anesth 2020; 34:2691-2697. [PMID: 32693966 DOI: 10.1053/j.jvca.2020.06.068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 06/16/2020] [Accepted: 06/18/2020] [Indexed: 11/11/2022]
Abstract
OBJECTIVES Three-dimensional (3D) transesophageal echocardiography (TEE) has been shown to be more accurate than 2D TEE for the evaluation of the left ventricular outflow tract area. The aim of the present study was to compare the agreement of 3D echocardiography-derived cardiac output (CO) with thermodilution-derived CO (TDCO) before and after cardiopulmonary bypass (CPB). DESIGN This was a prospective observational study of patients who underwent cardiac surgery between 2016 and 2018. SETTING Weill Cornell Medicine, a single large academic medical center. PARTICIPANTS The study comprised 78 patients undergoing elective cardiac surgery. INTERVENTIONS CPB, TEE, pulmonary artery catheter, and elective cardiac surgery. MEASUREMENTS AND MAIN RESULTS Two-dimensional CO, 3D CO-diameter, and 3D CO-area values pre-CPB were strongly correlated with one another both pre-CPB and post-CPB. The 3D CO-diameter and the 3D CO-area were mildly correlated, with TDCO measurements pre-CPB (r = 0.46 and 0.39, respectively) and post-CBP (r = 0.43 and 0.47, respectively). Pre-CPB 3D CO-diameter had the most agreement with TDCO in terms of bias (-0.13 L/min); however, the limits of agreement (LOA) were wide (-2.2- to- 2.45 L/min). Post-CPB, 3D CO-diameter had the most agreement with TDCO in terms of bias (0.41) but with wide LOA (-3.29 to 2.47). All pre-CPB echocardiography-derived CO (2D CO, 3D CO-diameter, 3D CO-area) had more agreement with TDCO than did post-CPB measurements. CONCLUSIONS Three-dimensional CO measurements were only modestly correlated with pulmonary artery catheter-derived CO pre-bypass and post-bypass. Despite low bias, the wide LOA from 2D CO, 3D CO-diameter, and 3D-area compared with TDCO suggested that the 2 methods are not interchangeable.
Collapse
Affiliation(s)
- Lisa Q Rong
- Department of Anesthesiology, Weill Cornell Medicine/New York Presbyterian, New York, NY.
| | - Mudit Kaushal
- Department of Anesthesiology, Weill Cornell Medicine/New York Presbyterian, New York, NY
| | - Elizabeth Mauer
- Department of Health Policy and Research, Weill Cornell Medicine/New York Presbyterian, New York, NY
| | - Kane O Pryor
- Department of Anesthesiology, Weill Cornell Medicine/New York Presbyterian, New York, NY
| | - Meaghan Kenfield
- Department of Anesthesiology, Weill Cornell Medicine/New York Presbyterian, New York, NY
| | | | - Mario F L Gaudino
- Department of Cardiothoracic Surgery, Weill Cornell Medicine/New York Presbyterian, New York, NY
| | - Peter J Neuburger
- Department of Anesthesiology, Perioperative Care, and Pain Medicine, NYU Langone Medical Center, New York, NY
| |
Collapse
|
6
|
Sarkar MS, Desai PM. Pulmonary hypertension and cardiac anesthesia: Anesthesiologist's perspective. Ann Card Anaesth 2018; 21:116-122. [PMID: 29652270 PMCID: PMC5914209 DOI: 10.4103/aca.aca_123_17] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Perioperative management of pulmonary hypertension remains one of the most challenging scenarios during cardiac surgery. It is associated with high morbidity and mortality due to right ventricular failure, arrhythmias, myocardial ischemia, and intractable hypoxia. Therefore, this review article is intended toward the anesthetic considerations in the perioperative period, with particular emphasis on the selection of technique and choice of anesthesia with maintenance, anesthetic drugs, and the recent intraoperative recommendations for prevention and treatment of pulmonary hypertensive crisis.
Collapse
Affiliation(s)
- Manjula Sudeep Sarkar
- Department of Anesthesiology, Seth GSMC and KEM Hospital, Mumbai, Maharashtra, India
| | - Pushkar M Desai
- Department of Anesthesiology, Seth GSMC and KEM Hospital, Mumbai, Maharashtra, India
| |
Collapse
|
7
|
Ellenberger C, Sologashvili T, Cikirikcioglu M, Verdon G, Diaper J, Cassina T, Licker M. Risk factors of postcardiotomy ventricular dysfunction in moderate-to-high risk patients undergoing open-heart surgery. Ann Card Anaesth 2018; 20:287-296. [PMID: 28701592 PMCID: PMC5535568 DOI: 10.4103/aca.aca_60_17] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Introduction: Ventricular dysfunction requiring inotropic support frequently occurs after cardiac surgery, and the associated low cardiac output syndrome largely contributes to postoperative death. We aimed to study the incidence and potential risk factors of postcardiotomy ventricular dysfunction (PCVD) in moderate-to-high risk patients scheduled for open-heart surgery. Methods: Over a 5-year period, we prospectively enrolled 295 consecutive patients undergoing valve replacement for severe aortic stenosis or coronary artery bypass surgery who presented with Bernstein-Parsonnet scores >7. The primary outcome was the occurrence of PCVD as defined by the need for sustained inotropic drug support and by transesophageal echography. The secondary outcomes included in-hospital mortality and the incidence of any major adverse events as well as Intensive Care Unit (ICU) and hospital length of stay. Results: The incidence of PCVD was 28.4%. Patients with PCVD experienced higher in-hospital mortality (12.6% vs. 0.6% in patients without PCVD) with a higher incidence of cardiopulmonary and renal complications as well as a prolonged stay in ICU (median + 2 days). Myocardial infarct occurred more frequently in patients with PCVD than in those without PCVD (19 [30.2%] vs. 12 [7.6%]). By logistic regression analysis, we identified four independent predictors of PCVD: left ventricular ejection fraction <40% (odds ratio [OR] = 6.36; 95% confidence interval [CI], 2.59–15.60), age older than 75 years (OR = 3.35; 95% CI, 1.64–6.81), prolonged aortic clamping time (OR = 3.72; 95% CI, 1.66–8.36), and perioperative bleeding (OR = 2.33; 95% CI, 1.01–5.41). The infusion of glucose-insulin-potassium was associated with lower risk of PCVD (OR = 0.14; 95% CI, 0.06–0.33). Conclusions: This cohort study indicates that age, preoperative ventricular function, myocardial ischemic time, and perioperative bleeding are predictors of PCVD which is associated with poor clinical outcome.
Collapse
Affiliation(s)
- Christoph Ellenberger
- Department of Anaesthesiology, Pharmacology and Intensive Care, University Hospital of Geneva, Geneva, Switzerland
| | - Tornike Sologashvili
- Division of Cardiovascular Surgery, University Hospital of Geneva, Geneva, Switzerland
| | - Mustafa Cikirikcioglu
- Division of Cardiovascular Surgery, University Hospital of Geneva, Geneva, Switzerland
| | - Gabriel Verdon
- Division of Cardiovascular Surgery, University Hospital of Geneva, Geneva, Switzerland
| | - John Diaper
- Department of Anaesthesiology, Pharmacology and Intensive Care, University Hospital of Geneva, Geneva, Switzerland
| | - Tiziano Cassina
- Department of Anesthesia and Intensive Care, Cardiocentro Ticino, Lugano; Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Marc Licker
- Department of Anaesthesiology, Pharmacology and Intensive Care, University Hospital of Geneva; Faculty of Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
8
|
Impact of Simulator-Based Training in Focused Transesophageal Echocardiography: A Randomized Controlled Trial. Anesth Analg 2017; 125:1140-1148. [PMID: 28817424 DOI: 10.1213/ane.0000000000002351] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND The aim of the study was to determine if training in transesophageal echocardiography (TEE) using a TEE simulator improves the ability of novice operators to perform and interpret a focused critical care TEE. METHODS In this prospective, randomized, controlled study with blinded outcome assessment, 44 intensive care unit trainees were randomly assigned to a control group receiving 4 hours of lecture-based training only, or an intervention group which was additionally trained for 4 hours using a TEE simulator. After the training intervention, each participant performed 2 TEEs in intensive care unit patients which were evaluated by blinded assessors. The imaging quality of TEEs was measured using a predefined examination quality score ranging from 0 to 100 points. The correct quantification of pathologies and the interpretation of the TEEs were evaluated by blinded assessors using focused and comprehensive expert TEEs as comparators. RESULTS A total of 114 TEEs were assessed. The mean examination quality score was 55.9 (95% confidence interval [CI], 50.3-61.5) for TEEs of the control group, 75.6 (95% CI, 70.1-81.0) for TEEs of the intervention group, and 88.5 (95% CI, 79.3-97.7) for TEEs in the expert group. The multiple comparisons revealed significant differences between all groups (19.7 [95% CI, 12.8-26.6], P < .001 for intervention versus control; 32.6 [95% CI, 23.0-42.3], P < .001 for expert versus control; 12.9 [95% CI, 3.4-22.5], P = .008 for expert versus intervention). Substantial agreement of the quantification and interpretation ratings of basic TEEs by the intervention (86.7% for quantification and 97.1% for interpretation) or expert group (93.2% for quantification and 98.4% for interpretation) with blinded assessors was detected. The control groups TEEs agreed less (75.6% for quantification and 91.8% for interpretation). CONCLUSIONS Simulation-based TEE training improves the ability of novice operators to perform a focused critical care TEE in comparison to lecture-based education only. After 8 hours of simulator and lecture-based training, the majority of TEEs of novices are of sufficient quality for clinical use. Furthermore, a substantial skill level in correct quantification and interpretation of imaging is achieved.
Collapse
|
9
|
Garijo JM, Mashari A, Meineri M. Role of Transesophageal Echocardiography in General Anesthesia. CURRENT ANESTHESIOLOGY REPORTS 2017. [DOI: 10.1007/s40140-017-0221-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|