Serane V T, Rajasekaran R, Vijayadevagaran V, Kothendaraman B. Peripheral intravenous cannulae in neonates: To splint or not?
J Vasc Access 2021;
23:398-402. [PMID:
33619983 DOI:
10.1177/1129729821996926]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVE
To determine the effect of splint on the dwell time of peripheral intravenous cannula in neonates.
SETTING
Level II Neonatal Intensive Care Unit (NICU).
PATIENTS
Consecutive babies with presumed need of peripheral intravenous access of at least 24 h.
METHODS
Enrolled subjects were randomized to "splint" or "splint-less" group. Insertion site was cleaned with Isopropyl alcohol and 2% Chlorhexidine and peripheral intravenous catheter was inserted under strict asepsis. Insertion sites was examined regularly for occurrence of complication which necessitated removal of the catheter.
RESULTS
Out of 159 neonates, 80 were allotted to splint group and the rest to splint-less group. Mean dwell time of intravenous line in splint group was 27.68 ± 13.03 h which was significantly less than in splint-less group (32.87 ± 15.79 h, mean difference: 5.11 h, p value: 0.03). Subgroup analysis in preterms showed mean dwell time of 28.54 ± 14.86 h in splint group which was less than that of splint-less group (35.10 ± 16.24 h) (p value: 0.03). No such difference was noted in the term neonates. Subgroup analysis for catheters put across joints does not show difference in mean dwell times between splint and splint-less groups. Multivariate regression analysis did not identify any variable which independently affected the outcome.
CONCLUSION
Use of splint does not prolong the dwell time of the catheter and is probably harmful in some neonates.