1
|
León-Muñoz VJ, Parrinello A, Galloni G, Lisón-Almagro AJ, López-López M, Martínez-Martínez F, Santonja-Medina F. Reliability of the posterior condylar offset. J Orthop Res 2022; 40:1794-1800. [PMID: 34717014 DOI: 10.1002/jor.25205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 10/19/2021] [Indexed: 02/04/2023]
Abstract
The posterior condylar offset (PCO) has been proposed as a determinant of a postoperative range of motion after total knee arthroplasty, although there is no consensus. This study aimed to demonstrate the error introduced by forcing the femoral rotation to overlap both condyles for the "true" lateral X-ray projection for the PCO measurement. We hypothesize that the angular discrepancy between the posterior femoral cortical reference plane and the posterior condylar axis plane due to rotation invalidates the acquisition of reliable measurements on X-rays. We have measured the PCO in 50 "true" lateral X-rays and compared it with the medial and lateral condyles PCO's assessed on a computed tomography-scan-based three-dimensional (3D) model of each knee. PCO based on the 3D imaging differed significantly between the medial (25.8 ± 3.67 mm) and lateral (16.59 ± 2.92 mm) condyle. Three-dimensional PCO values differ significantly from those determined in the radiographic studies. Also, the mean values of the medial and lateral condyle PCO measurements differed significantly (p < 0.001) with all PCO measurements on radiographs. We have identified a difference between the posterior cortical plane and the posterior condylar axis projections, both on the axial plane with a mean value of 11.23° ± 3.64°. Our data show an interplane discrepancy angle between the posterior femoral diaphyseal cortical and the posterior condylar axis plane (due to the femur's necessary rotation to overlap both condyles) may invalidate the 2D X-ray PCO assessment as a reliable measurement.
Collapse
Affiliation(s)
- Vicente J León-Muñoz
- Department of Orthopedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, Murcia, Spain
| | - Andrea Parrinello
- Product Management Department, Medacta International SA, Castel San Pietro, Switzerland
| | - Gianluca Galloni
- Patient Matched Technology Department, Medacta International SA, Castel San Pietro, Switzerland
| | - Alonso J Lisón-Almagro
- Department of Orthopedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, Murcia, Spain
| | - Mirian López-López
- Subdirección General de Tecnologías de la Información, Servicio Murciano de Salud, Murcia, Spain
| | - Francisco Martínez-Martínez
- Department of Orthopedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain.,Department of Surgery, Pediatrics and Obstetrics and Gynecology, Faculty of Medicine, University of Murcia, Murcia, Spain
| | - Fernando Santonja-Medina
- Department of Orthopedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain.,Department of Surgery, Pediatrics and Obstetrics and Gynecology, Faculty of Medicine, University of Murcia, Murcia, Spain
| |
Collapse
|