Nicolini LF, Oliveira RC, Ribeiro M, Stoffel M, Markert B, Kobbe P, Hildebrand F, Trobisch P, Simões MS, de Mello Roesler CR, Fancello EA. Tether pre-tension within vertebral body tethering reduces motion of the spine and influences coupled motion: a finite element analysis. Comput Biol Med 2024; 169:107851. [PMID: 38113683 DOI: 10.1016/j.compbiomed.2023.107851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 11/30/2023] [Accepted: 12/11/2023] [Indexed: 12/21/2023]
Abstract
Anterior Vertebral Body Tethering (VBT) is a novel fusionless treatment option for selected adolescent idiopathic scoliosis patients which is gaining widespread interest. The primary objective of this study is to investigate the effects of tether pre-tension within VBT on the biomechanics of the spine including sagittal and transverse parameters as well as primary motion, coupled motion, and stresses acting on the L2 superior endplate. For that purpose, we used a calibrated and validated Finite Element model of the L1-L2 spine. The VBT instrumentation was inserted on the left side of the L1-L2 segment with different cord pre-tensions and submitted to an external pure moment of 6 Nm in different directions. The range of motion (ROM) for the instrumented spine was measured from the initial post-VBT position. The magnitudes of the ROM of the native spine and VBT-instrumented with pre-tensions of 100 N, 200 N, and 300 N were, respectively, 3.29°, 2.35°, 1.90° and 1.61° in extension, 3.30°, 3.46°, 2.79°, and 2.17° in flexion, 2.11°, 1.67°, 1.33° and 1.06° in right axial rotation, and 2.10°, 1.88°, 1.48° and 1.16° in left axial rotation. During flexion-extension, an insignificant coupled lateral bending motion was observed in the native spine. However, VBT instrumentation with pre-tensions of 100 N, 200 N, and 300 N generated coupled right lateral bending of 0.85°, 0.81°, and 0.71° during extension and coupled left lateral bending of 0.32°, 0.24°, and 0.19° during flexion, respectively. During lateral bending, a coupled extension motion of 0.33-0.40° is observed in the native spine, but VBT instrumentation with pre-tensions of 100 N, 200 N, and 300 N generates coupled flexion of 0.67°, 0.58°, and 0.42° during left (side of the implant) lateral bending and coupled extension of 1.28°, 1.07°, and 0.87° during right lateral bending, respectively. Therefore, vertebral body tethering generates coupled motion. Tether pre-tension within vertebral body tethering reduces the motion of the spine.
Collapse
Affiliation(s)
- Luis Fernando Nicolini
- Group of Analysis and Mechanical Design - GRANTE, Dep. of Mechanical Engineering, Federal University of Santa Catarina, Brazil; Mechanical and Aerospace Technology Laboratory (NUMAE), Dep. of Mechanical Engineering, Federal University of Santa Maria, Brazil.
| | - Rafael Carreira Oliveira
- Group of Analysis and Mechanical Design - GRANTE, Dep. of Mechanical Engineering, Federal University of Santa Catarina, Brazil
| | - Marx Ribeiro
- Group of Analysis and Mechanical Design - GRANTE, Dep. of Mechanical Engineering, Federal University of Santa Catarina, Brazil; Department of Orthopedics, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Marcus Stoffel
- Institute of General Mechanics (IAM), RWTH Aachen University, Germany
| | - Bernd Markert
- Institute of General Mechanics (IAM), RWTH Aachen University, Germany
| | - Philipp Kobbe
- Department of Orthopedics, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Frank Hildebrand
- Department of Orthopedics, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstr. 30, 52074, Aachen, Germany
| | | | - Marcelo Simoni Simões
- Biomechanical Engineering Laboratory - LEBm, Dep. of Mechanical Engineering, Federal University of Santa Catarina, Brazil
| | - Carlos Rodrigo de Mello Roesler
- Group of Analysis and Mechanical Design - GRANTE, Dep. of Mechanical Engineering, Federal University of Santa Catarina, Brazil; Biomechanical Engineering Laboratory - LEBm, Dep. of Mechanical Engineering, Federal University of Santa Catarina, Brazil
| | - Eduardo Alberto Fancello
- Group of Analysis and Mechanical Design - GRANTE, Dep. of Mechanical Engineering, Federal University of Santa Catarina, Brazil; Biomechanical Engineering Laboratory - LEBm, Dep. of Mechanical Engineering, Federal University of Santa Catarina, Brazil
| |
Collapse
|
2
|
Alfraihat A, Samdani AF, Balasubramanian S. Predicting radiographic outcomes of vertebral body tethering in adolescent idiopathic scoliosis patients using machine learning. PLoS One 2024; 19:e0296739. [PMID: 38215180 PMCID: PMC10786366 DOI: 10.1371/journal.pone.0296739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 12/18/2023] [Indexed: 01/14/2024] Open
Abstract
Anterior Vertebral Body Tethering (AVBT) is a growing alternative treatment for adolescent idiopathic scoliosis (AIS), offering an option besides spinal fusion. While AVBT aims to correct spinal deformity through growth correction, its outcomes have been mixed. To improve surgical outcomes, this study aimed to develop a machine learning-based tool to predict short- and midterm spinal curve correction in AIS patients who underwent AVBT surgery, using the most predictive clinical, radiographic, and surgical parameters. After institutional review board approval and based on inclusion criteria, 91 AIS patients who underwent AVBT surgery were selected from the Shriners Hospitals for Children, Philadelphia. For all patients, longitudinal standing (PA or AP, and lateral) and side bending spinal Radiographs were retrospectively obtained at six visits: preop and first standing, one year, two years, five years postop, and at the most recent follow-up. Demographic, radiographic, and surgical features associated with curve correction were collected. The sequential backward feature selection method was used to eliminate correlated features and to provide a rank-ordered list of the most predictive features of the AVBT correction. A Gradient Boosting Regressor (GBR) model was trained and tested using the selected features to predict the final correction of the curve in AIS patients. Eleven most predictive features were identified. The GBR model predicted the final Cobb angle with an average error of 6.3 ± 5.6 degrees. The model also provided a prediction interval, where 84% of the actual values were within the 90% prediction interval. A list of the most predictive features for AVBT curve correction was provided. The GBR model, trained on these features, predicted the final curve magnitude with a clinically acceptable margin of error. This model can be used as a clinical tool to plan AVBT surgical parameters and improve outcomes.
Collapse
Affiliation(s)
- Ausilah Alfraihat
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States of America
- Hashemite University, Zarqa, Jordan
| | - Amer F. Samdani
- Shriners Hospitals for Children, Philadelphia, PA, United States of America
| | - Sriram Balasubramanian
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States of America
| |
Collapse
|
3
|
Pjanić S, Talić G, Bojinović-Rodić D. Impact of body mass index on the initial in-brace correction in patients with idiopathic scoliosis. SCRIPTA MEDICA 2021. [DOI: 10.5937/scriptamed52-29309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
Abstract
Background/Aim: Many factors affect initial in-brace correction and treatment outcome in patients with idiopathic scoliosis. Previous studies have observed contradictory results on the role of BMI in orthotic treatment. The aim of this study was to examine whether BMI impacts in-brace correction, isolated and in relation to other predictive factors (curve magnitude, curve location and Risser sign). Methods: A retrospective study has been conducted on patients with idiopathic scoliosis treated with Cheneau-Sobernheim brace, that had no prior treatment. The collected and analysed data included patient demographics, BMI percentile and radiological parameters (curve magnitude in Cobb angle, curve location, Risser sign). The initial in-brace correction was expressed as a percentage of Cobb angle reduction in the brace as opposed to Cobb angle out of brace. Patients were categorised into groups according to their BMI, expressed in percentiles, ie: low BMI (< 5 percentiles), normal BMI (5-85 percentiles) and high BMI (> 85 percentiles). To determine the significant difference and correlation relationship between the examined variables, variance tests, t-test with unequal variance, and Pearson correlation coefficient have been used. Results: The cohort study comprised 213 patients (170 females and 43 males) with a mean age of 13.5 years at brace prescription. Low BMI has been detected in 10 % patients, normal BMI in 78 % and high BMI in 10 % patients. No significant difference in in-brace correction has been found between BMI groups, nor has there been any significant correlation between BMI and in-brace correction. Regarding other factors, significant difference within BMI groups was found between in-brace correction and curve location, as well as in-brace correction and Risser sign. Lumbar curves had significantly better in-brace correction than thoracic curves. Significant correlations between in-brace correction and curve magnitude, curve location and Risser sign were detected. Conclusion: The results of the present study show that, as an independent factor, BMI does not impact in-brace correction. Other factors, such as curve magnitude, curve location and Risser sign, play a more significant role in the orthotic treatment of patients with idiopathic scoliosis.
Collapse
|
4
|
Thoracoscopic Vertebral Body Tethering for Adolescent Idiopathic Scoliosis: Follow-up Curve Behavior According to Sanders Skeletal Maturity Staging. Spine (Phila Pa 1976) 2020; 45:E1483-E1492. [PMID: 32756290 DOI: 10.1097/brs.0000000000003643] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Retrospective analysis of prospectively collected data. OBJECTIVE To report the follow-up curve behaviors in different Sanders staging groups. SUMMARY OF BACKGROUND DATA Vertebral body tethering (VBT) is a growth modulation technique that allows gradual spontaneous follow-up curve correction as the patient grows. There is a lack of scientific evidence regarding appropriate patient selection and timing of implantation. METHODS Patients were grouped into five as: Sanders 1, 2, 3, 4-5, and 6-7. Data were collected preoperatively, at the day before discharge, and at each follow-up. Outcome measures were pulmonary and mechanical complications, readmission, and reoperation rates. Demographic, perioperative, clinical, radiographic, and complication data were compared using Fisher-Freeman-Halton exact tests for categorical variables and Kruskal-Wallis tests for the continuous variables. RESULTS Thirty-one (29 F, 2 M) consecutive patients with a minimum of 12 months of follow-up were included. The mean age at surgery was 12.1 (10-14). The mean follow-up was 27.1 (12-62) months. The mean preoperative main thoracic curve magnitude was 47° ± 7.6°. For all curves, preoperative and first erect curve magnitudes, bending flexibility, and operative correction percentages were similar between groups (for all comparisons, P > 0.05). The median height gained during follow-up was different between groups (P < 0.001), which was reflected into median curve correction during follow-up. Total curve correction percentage was different between groups (P = 0.009). Four (12.9%) patients had pulmonary and six (19.4%) had mechanical complications. One (3.2%) patient required readmission and two (6.5%) required reoperation. Occurrence of pulmonary complications was similar in Sanders groups (P = 0.804), while mechanical complications and overcorrection was significantly higher in Sanders 2 patients (P = 0.002 and P = 0.018). CONCLUSION Follow-up curve behavior after VBT is different in patients having different Sanders stages. Sanders 2 patients experienced more overcorrection, thus timing and/or correction should be adjusted, since Sanders 3, 4, and 5 patients displayed a lesser risk of mechanical complications. LEVEL OF EVIDENCE 3.
Collapse
|
5
|
Population-based design and 3D finite element analysis of transforaminal thoracic interbody fusion cages. J Orthop Translat 2020; 21:35-40. [PMID: 32071873 PMCID: PMC7013106 DOI: 10.1016/j.jot.2019.12.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Revised: 12/12/2019] [Accepted: 12/16/2019] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE To compare the biomechanical characteristics of two transforaminal thoracic interbody fusion cages based on the Chinese population thoracic anatomy. METHOD Computed tomography scans of the thoracic spine of 150 patients from our institution were collected and analysed. Two cages were designed based on the anatomical parameters of these patients. Further, we used 3D finite element analysis models to compare the stability of two cages by using Mimics 17.0 and ANSYS 15.0 software. RESULT Two kinds of thoracic cages (box and kidney-shaped) were designed. Under the displacement working condition, the two new fusion cages could achieve immediate postoperative stability, but the kidney-shaped cage was better than the box-shaped cage. Under the stress working condition, no highly focused stress area was found in either cages, but the kidney-shaped cage experienced less stress than the box-shaped cage. CONCLUSION The kidney-shaped cage is more stable and experiences lesser stress than the box-shaped cage after thoracic intervertebral fusion, and it is more suitable for Chinese transforaminal thoracic interbody fusion. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE This article is about thoracic fusion cage design and finite element analysis (FEA) analysis based on the thoracic anatomy parameters. For there is currently no suitable thoracic fusion cage for transforaminal thoracic interbody fusion, the results in this article may have the potential of transferring the two designed cages into clinical use.
Collapse
|
6
|
Prediction outcomes for anterior vertebral body growth modulation surgery from discriminant spatiotemporal manifolds. Int J Comput Assist Radiol Surg 2019; 14:1565-1575. [DOI: 10.1007/s11548-019-02041-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Accepted: 07/23/2019] [Indexed: 10/26/2022]
|
7
|
Contribution of Lateral Decubitus Positioning and Cable Tensioning on Immediate Correction in Anterior Vertebral Body Growth Modulation. Spine Deform 2019; 6:507-513. [PMID: 30122385 DOI: 10.1016/j.jspd.2018.01.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Revised: 12/22/2017] [Accepted: 01/29/2018] [Indexed: 11/23/2022]
Abstract
STUDY DESIGN Computational simulation of lateral decubitus and anterior vertebral body growth modulation (AVBGM). OBJECTIVES To biomechanically evaluate lateral decubitus and cable tensioning contributions on intra- and postoperative correction. SUMMARY OF BACKGROUND DATA AVBGM is a compression-based fusionless procedure to treat progressive pediatric scoliosis. During surgery, the patient is positioned in lateral decubitus, which reduces spinal curves. The deformity is further corrected with the application of compression by cable tensioning. Predicting postoperative correction following AVBGM installation remains difficult. METHODS Twenty pediatric scoliotic patients instrumented with AVBGM were recruited. Three-dimensional (3D) reconstructions obtained from calibrated biplanar radiographs were used to generate a personalized finite element model. Intraoperative lateral decubitus position and installation of AVBGM were simulated to evaluate the intraoperative positioning and cable tensioning (100 / 150 / 200 N) relative contribution on intra- and postoperative correction. RESULTS Average Cobb angles prior to surgery were 56° ± 10° (thoracic) and 38° ± 8° (lumbar). Simulated presenting growth plate's stresses were of 0.86 MPa (concave side) and 0.02 MPa (convex side). The simulated lateral decubitus reduced Cobb angles on average by 30% (thoracic) and 18% (lumbar). Cable tensioning supplementary contribution on intraoperative spinal correction was of 15%, 18%, and 24% (thoracic) for 100, 150, and 200 N, respectively. Simulated Cobb angles for the postoperative standing position were 39°, 37°, and 33° (thoracic) and 30°, 29°, and 28° (lumbar), respectively, whereas growth plate's stresses were of 0.54, 0.53, and 0.51 MPa (concave side) and 0.36, 0.53, and 0.68 MPa (convex side) for the three tensions. CONCLUSION The majority of curve correction was achieved by lateral decubitus positioning. The main role of the cable was to apply supplemental periapical correction and secure the intraoperative positioning correction. Increases in cable tensioning furthermore rebalanced initially asymmetric compressive stresses. This study could help improve the design of AVBGM by understanding the contributions of the surgical procedure components to the overall correction achieved. LEVEL OF EVIDENCE Level III.
Collapse
|
8
|
Cobetto N, Aubin CE, Parent S. Surgical Planning and Follow-up of Anterior Vertebral Body Growth Modulation in Pediatric Idiopathic Scoliosis Using a Patient-Specific Finite Element Model Integrating Growth Modulation. Spine Deform 2019; 6:344-350. [PMID: 29886903 DOI: 10.1016/j.jspd.2017.11.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 11/10/2017] [Accepted: 11/14/2017] [Indexed: 11/25/2022]
Abstract
STUDY DESIGN Numerical planning and simulation of immediate and post-two-year growth modulation effects of Anterior Vertebral Body Growth Modulation (AVBGM). OBJECTIVES To develop a planning tool based on a patient-specific finite element model (FEM) of pediatric scoliosis integrating growth to computationally assess the 3D biomechanical effects of AVBGM. SUMMARY OF BACKGROUND DATA AVBGM is a recently introduced fusionless compression-based approach for pediatric scoliotic patients presenting progressive curves. Surgical planning is mostly empirical, with reported issues including overcorrection (inversion of the side) of the curve and a lack of control on 3D correction. METHODS Twenty pediatric scoliotic patients instrumented with AVBGM were assessed. An osseoligamentous FEM of the spine, rib cage, and pelvis was generated before surgery using the patient's 3D reconstruction obtained from calibrated biplanar radiographs. For each case, different scenarios of AVBGM and two years of vertebral growth and growth modulation due to gravitational loads and forces from AVBGM were simulated. Simulated correction indices in the coronal, sagittal, and transverse planes for the retained scenario were computed and a posteriori compared to actual patient's postoperative and two years' follow-up data. RESULTS The simulated immediate postoperative Cobb angles were on average within 3° of that of the actual correction, while it was ±5° for kyphosis/lordosis angles, and ±5° for apical axial rotation. For the simulated 2-year postoperative follow-up, correction results were predicted at ±3° for Cobb angles and ±5° for kyphosis/lordosis angles, ±2% for T1-L5 height, and ±4° for apical axial rotation. CONCLUSION A numeric model simulating immediate and post-two-year effects of AVBGM enabled to assess different implant configurations to support surgical planning. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Nikita Cobetto
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Downtown Station, Montreal, Quebec H3C 3A7, Canada; Research Center, Sainte-Justine University Hospital Center, 3175 Côte-Sainte-Catherine Road, Montreal, Quebec H3T 1C5, Canada
| | - Carl-Eric Aubin
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Downtown Station, Montreal, Quebec H3C 3A7, Canada; Research Center, Sainte-Justine University Hospital Center, 3175 Côte-Sainte-Catherine Road, Montreal, Quebec H3T 1C5, Canada.
| | - Stefan Parent
- Research Center, Sainte-Justine University Hospital Center, 3175 Côte-Sainte-Catherine Road, Montreal, Quebec H3T 1C5, Canada
| |
Collapse
|
9
|
Dynamic Response of the Lumbar Spine to Whole-body Vibration Under a Compressive Follower Preload. Spine (Phila Pa 1976) 2018; 43:E143-E153. [PMID: 28538593 DOI: 10.1097/brs.0000000000002247] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN A finite element study of dynamic response of the lumbar spine to whole-body vibration. OBJECTIVE The aim of this study was to develop and validate a finite element model for exploring the impact of whole-body vibration on the entire lumbar spine with a compressive follower preload applied. SUMMARY OF BACKGROUND DATA Several finite element studies have investigated the biodynamic characteristics of the human lumbar spine when exposed to whole-body vibration. However, very limited studies have been performed to quantitatively describe dynamic response in time domain of the entire lumbar spine to vibration loading under a compressive follower preload. METHODS A three-dimensional nonlinear finite element model of the human lumbar spine (L1-sacrum) subjected to the compressive follower preload was created. Transient dynamic analysis was conducted on the model to compute the spinal response to a sinusoidal vertical vibration load of ±40 N under a 400 N preload. The obtained dynamic response results at all spinal levels were collected and plotted as a function of time. As a comparison, the corresponding results for vertical static loads (-40 and 40 N) under the preload (400 N) were also computed. RESULTS Plots of the dynamic response at all levels showed a cyclic response with time, and their vibration amplitudes (peak-to-bottom variations) were markedly higher than the corresponding changing amplitudes of static load cases. The increasing effect of the vibration load reached 314.5%, 263.2%, 242.4%, and 232.7%, respectively, in axial displacement of vertebral center, disc bulge, intradiscal pressure, and annulus stress (von-Mises stress). In addition, increasing the compressive follower preload led to an increase in the dynamic response and a decrease in their vibration amplitudes. CONCLUSION This study may be useful to help quantify the effect of cyclic loading on the entire lumbar spine under physiologic compressive loading, and better understand vibration characteristics of the spine. LEVEL OF EVIDENCE 5.
Collapse
|
10
|
Negrini S, Donzelli S, Aulisa AG, Czaprowski D, Schreiber S, de Mauroy JC, Diers H, Grivas TB, Knott P, Kotwicki T, Lebel A, Marti C, Maruyama T, O’Brien J, Price N, Parent E, Rigo M, Romano M, Stikeleather L, Wynne J, Zaina F. 2016 SOSORT guidelines: orthopaedic and rehabilitation treatment of idiopathic scoliosis during growth. SCOLIOSIS AND SPINAL DISORDERS 2018; 13:3. [PMID: 29435499 PMCID: PMC5795289 DOI: 10.1186/s13013-017-0145-8] [Citation(s) in RCA: 410] [Impact Index Per Article: 68.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Accepted: 11/06/2017] [Indexed: 02/06/2023]
Abstract
BACKGROUND The International Scientific Society on Scoliosis Orthopaedic and Rehabilitation Treatment (SOSORT) produced its first guidelines in 2005 and renewed them in 2011. Recently published high-quality clinical trials on the effect of conservative treatment approaches (braces and exercises) for idiopathic scoliosis prompted us to update the last guidelines' version. The objective was to align the guidelines with the new scientific evidence to assure faster knowledge transfer into clinical practice of conservative treatment for idiopathic scoliosis (CTIS). METHODS Physicians, researchers and allied health practitioners working in the area of CTIS were involved in the development of the 2016 guidelines. Multiple literature reviews reviewing the evidence on CTIS (assessment, bracing, physiotherapy, physiotherapeutic scoliosis-specific exercises (PSSE) and other CTIS) were conducted. Documents, recommendations and practical approach flow charts were developed using a Delphi procedure. The process was completed with the Consensus Session held during the first combined SOSORT/IRSSD Meeting held in Banff, Canada, in May 2016. RESULTS The contents of the new 2016 guidelines include the following: background on idiopathic scoliosis, description of CTIS approaches for various populations with flow-charts for clinical practice, as well as literature reviews and recommendations on assessment, bracing, PSSE and other CTIS. The present guidelines include a total of 68 recommendations divided into following topics: bracing (n = 25), PSSE to prevent scoliosis progression during growth (n = 12), PSSE during brace treatment and surgical therapy (n = 6), other conservative treatments (n = 2), respiratory function and exercises (n = 3), general sport activities (n = 6); and assessment (n = 14). According to the agreed strength and level of evidence rating scale, there were 2 recommendations on bracing and 1 recommendation on PSSE that reached level of recommendation "I" and level of evidence "II". Three recommendations reached strength of recommendation A based on the level of evidence I (2 for bracing and one for assessment); 39 recommendations reached strength of recommendation B (20 for bracing, 13 for PSSE, and 6 for assessment).The number of paper for each level of evidence for each treatment is shown in Table 8. CONCLUSION The 2016 SOSORT guidelines were developed based on the current evidence on CTIS. Over the last 5 years, high-quality evidence has started to emerge, particularly in the areas of efficacy of bracing (one large multicentre trial) and PSSE (three single-centre randomized controlled trials). Several grade A recommendations were presented. Despite the growing high-quality evidence, the heterogeneity of the study protocols limits generalizability of the recommendations. There is a need for standardization of research methods of conservative treatment effectiveness, as recognized by SOSORT and the Scoliosis Research Society (SRS) non-operative management Committee.
Collapse
Affiliation(s)
- Stefano Negrini
- Clinical and Experimental Sciences Department, University of Brescia Viale Europa 11, Brescia, Italy
- IRCCS Fondazione Don Gnocchi, Milan, Italy
| | - Sabrina Donzelli
- ISICO (Italian Scientific Spine Institute), Via R. Bellarmino 13/1, 20141 Milan, Italy
| | - Angelo Gabriele Aulisa
- U.O.C. of Orthopedics and Traumatology, Children’s Hospital Bambino Gesù, Institute of Scientific Research, 00165 Rome, Italy
| | - Dariusz Czaprowski
- Center of Body Posture, Olsztyn, Poland
- Department of Physiotherapy, Józef Rusiecki University College, Olsztyn, Poland
| | - Sanja Schreiber
- Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, Canada
- Alberta Health Services, Department of Surgery, Edmonton, Canada
| | | | - Helmut Diers
- Department of Orthopedics and Trauma Surgery, University Medical Center, Mainz, Germany
| | - Theodoros B. Grivas
- Department of Orthopaedics and Traumatology, “Tzaneio” General Hospital of Piraeus, Piraeus, Greece
| | - Patrick Knott
- Rosalind Franklin University of Medicine and Science, North Chicago, IL USA
| | - Tomasz Kotwicki
- Department of Spine Disorders and Pediatric Orthopedics, University of Medical Sciences, Poznan, Poland
| | - Andrea Lebel
- Scoliosis Physiotherapy & Posture Centre, 231 McLeod Street, Ottawa, Ontario K2P0Z8 Canada
| | - Cindy Marti
- Schroth-Barcelona Institute, LLC, Spinal Dynamics of Wisconsin, SC., Barcelona, Spain
| | - Toru Maruyama
- Saitama Prefectural Rehabilitation Center, Saitama, Japan
| | - Joe O’Brien
- National Scoliosis Foundation, Stoughton, MA USA
| | - Nigel Price
- Section of Spine Surgery, Children’s Mercy Hospitals and Clinics, UMKC Orthopedics, Kansas City, MO USA
| | - Eric Parent
- Department of Physical Therapy, 2-50 Corbett Hall, Edmonton, AB T6G 2G4 Canada
| | - Manuel Rigo
- Salvá SLP (E. Salvá Institute), Vía Augusta 185, 08021 Barcelona, Spain
| | - Michele Romano
- ISICO (Italian Scientific Spine Institute), Via R. Bellarmino 13/1, 20141 Milan, Italy
| | - Luke Stikeleather
- National Scoliosis Center, 3023 Hamaker Court, Suite LL-50, Fairfax, VA 22124 USA
| | - James Wynne
- Boston Orthotics & Prosthetics, Boston, MA USA
| | - Fabio Zaina
- ISICO (Italian Scientific Spine Institute), Via R. Bellarmino 13/1, 20141 Milan, Italy
| |
Collapse
|
11
|
Cobetto N, Parent S, Aubin CE. 3D correction over 2years with anterior vertebral body growth modulation: A finite element analysis of screw positioning, cable tensioning and postoperative functional activities. Clin Biomech (Bristol, Avon) 2018; 51:26-33. [PMID: 29169117 DOI: 10.1016/j.clinbiomech.2017.11.007] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 11/14/2017] [Accepted: 11/15/2017] [Indexed: 02/07/2023]
Abstract
BACKGROUND Anterior vertebral body growth modulation is a fusionless instrumentation to correct scoliosis using growth modulation. The objective was to biomechanically assess effects of cable tensioning, screw positioning and post-operative position on tridimensional correction. METHODS The design of experiments included two variables: cable tensioning (150/200N) and screw positioning (lateral/anterior/triangulated), computationally tested on 10 scoliotic cases using a personalized finite element model to simulate spinal instrumentation, and 2years growth modulation with the device. Dependent variables were: computed Cobb angles, kyphosis, lordosis, axial rotation and stresses exerted on growth plates. Supine functional post-operative position was simulated in addition to the reference standing position to evaluate corresponding growth plate's stresses. FINDINGS Simulated cable tensioning and screw positioning had a significant impact on immediate and after 2years Cobb angle (between 5°-11°, p<0.01). Anterior screw positioning significantly increased kyphosis after 2years (6°-8°, p=0.02). Triangulated screw positioning did not significantly impact axial rotation but significantly reduced kyphosis (8°-10°, p=0.001). Growth plates' stresses were increased by 23% on the curve's convex side with cable tensioning, while screw positioning rather affected anterior/posterior distributions. Supine position significantly affected stress distributions on the apical vertebra compared to standing position (respectively 72% of compressive stresses on convex side vs 55%). INTERPRETATION This comparative numerical study showed the biomechanical possibility to adjust the fusionless instrumentation parameters to improve correction in frontal and sagittal planes, but not in the transverse plane. The convex side stresses increase in the supine position may suggest that growth modulation could be accentuated during nighttime.
Collapse
Affiliation(s)
- Nikita Cobetto
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Downtown Station, Montreal, Quebec H3C 3A7, Canada; Research Center, Sainte-Justine University Hospital Center, 3175 Côte-Sainte-Catherine Road, Montreal, Quebec H3T 1C5, Canada
| | - Stefan Parent
- Research Center, Sainte-Justine University Hospital Center, 3175 Côte-Sainte-Catherine Road, Montreal, Quebec H3T 1C5, Canada
| | - Carl-Eric Aubin
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Downtown Station, Montreal, Quebec H3C 3A7, Canada; Research Center, Sainte-Justine University Hospital Center, 3175 Côte-Sainte-Catherine Road, Montreal, Quebec H3T 1C5, Canada.
| |
Collapse
|
12
|
Aubin CÉ, Clin J, Rawlinson J. Biomechanical simulations of costo-vertebral and anterior vertebral body tethers for the fusionless treatment of pediatric scoliosis. J Orthop Res 2018; 36:254-264. [PMID: 28685857 DOI: 10.1002/jor.23648] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Accepted: 06/30/2017] [Indexed: 02/04/2023]
Abstract
Compression-based fusionless tethers are an alternative to conventional surgical treatments of pediatric scoliosis. Anterior approaches place an anterior (ANT) tether on the anterolateral convexity of the deformed spine to modify growth. Posterior, or costo-vertebral (CV), approaches have not been assessed for biomechanical and corrective effectiveness. The objective was to biomechanically assess CV and ANT tethers using six patient-specific, finite element models of adolescent scoliotic patients (11.9 ± 0.7 years, Cobb 34° ± 10°). A validated algorithm simulated the growth and Hueter-Volkmann growth modulation over a period of 2 years with the CV and ANT tethers at two initial tensions (100, 200 N). The models without tethering also simulated deformity progression with Cobb angle increasing from 34° to 56°, axial rotation 11° to 13°, and kyphosis 28° to 32° (mean values). With the CV tether, the Cobb angle was reduced to 27° and 20° for tensions of 100 and 200 N, respectively, kyphosis to 21° and 19°, and no change in axial rotation. With the ANT tether, Cobb was reduced to 32° and 9° for 100 and 200 N, respectively, kyphosis unchanged, and axial rotation to 3° and 0°. While the CV tether mildly corrected the coronal curve over a 2-year growth period, it had sagittal lordosing effect, particularly with increasing initial axial rotation (>15°). The ANT tether achieved coronal correction, maintained kyphosis, and reduced the axial rotation, but over-correction was simulated at higher initial tensions. This biomechanical study captured the differences between a CV and ANT tether and indicated the variability arising from the patient-specific characteristics. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:254-264, 2018.
Collapse
Affiliation(s)
- Carl-Éric Aubin
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Station Centre-Ville, Montréal, Québec, Canada H3C 3A7.,Sainte-Justine University Hospital Center, 3175 Côte-Ste-Catherine Rd., Montréal, Québec, Canada H3T 1C5
| | - Julien Clin
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Station Centre-Ville, Montréal, Québec, Canada H3C 3A7.,Sainte-Justine University Hospital Center, 3175 Côte-Ste-Catherine Rd., Montréal, Québec, Canada H3T 1C5
| | - Jeremy Rawlinson
- Medtronic, Spinal Applied Research, 1800 Pyramid Place, Memphis 38132, Tennessee
| |
Collapse
|
13
|
In vitro analysis of the segmental flexibility of the thoracic spine. PLoS One 2017; 12:e0177823. [PMID: 28520819 PMCID: PMC5433776 DOI: 10.1371/journal.pone.0177823] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 05/03/2017] [Indexed: 11/19/2022] Open
Abstract
Basic knowledge about the thoracic spinal flexibility is limited and to the authors' knowledge, no in vitro studies have examined the flexibility of every thoracic spinal segment under standardized experimental conditions using pure moments. In our in vitro study, 68 human thoracic functional spinal units including the costovertebral joints (at least n = 6 functional spinal units per segment from T1-T2 to T11-T12) were loaded with pure moments of ±7.5 Nm in flexion/extension, lateral bending, and axial rotation in a custom-built spine tester to analyze range of motion (ROM) and neutral zone (NZ). ROM and NZ showed symmetric motion behavior in all loading planes. In each loading direction, the segment T1-T2 exhibited the highest ROM. In flexion/extension, the whole thoracic region, with exception of T1-T2 (14°), had an average ROM between 6° and 8°. In lateral bending, the upper thoracic region (T1-T7) was, with an average ROM between 10° and 12°, more flexible than the lower thoracic region (T7-T12) with an average ROM between 8° and 9°. In axial rotation, the thoracic region offered the highest overall flexibility with an average ROM between 10° and 12° in the upper and middle thoracic spine (T1-T10) and between 7° and 8° in the lower thoracic spine (T10-T12), while a trend of continuous decrease of ROM could be observed in the lower thoracic region (T7-T12). Comparing these ROM values with those in literature, they agree that ROM is lowest in flexion/extension and highest in axial rotation, as well as decreasing in the lower segments in axial rotation. Differences were found in flexion/extension and lateral bending in the lower segments, where, in contrast to the literature, no increase of the ROM from superior to inferior segments was found. The data of this in vitro study could be used for the validation of numerical models and the design of further in vitro studies of the thoracic spine without the rib cage, the verification of animal models, as well as the interpretation of already published human in vitro data.
Collapse
|
14
|
Porcine spine finite element model: a complementary tool to experimental scoliosis fusionless instrumentation. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2017; 26:1610-1617. [DOI: 10.1007/s00586-016-4940-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Revised: 12/21/2016] [Accepted: 12/25/2016] [Indexed: 10/20/2022]
|
15
|
Local Epiphyseal Growth Modulation for the Early Treatment of Progressive Scoliosis: Experimental Validation Using a Porcine Model. Spine (Phila Pa 1976) 2016; 41:E1009-E1015. [PMID: 26863259 DOI: 10.1097/brs.0000000000001496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Experimental study of a localized device for the control of the vertebral growth using an immature porcine model. OBJECTIVE The aim of the study was to experimentally evaluate a localized device acting on the epiphyseal growth plates without bridging the intervertebral disc of immature hybrid pigs over 3 months of growth. SUMMARY OF BACKGROUND DATA Based on current published literature, fusionless devices offer promising scoliosis treatment alternatives to conventional spinal instrumentation and fusion in the growing spine. Current compression-based devices achieve growth modulation while also compressing the intervertebral discs, increasing the risk of long-term disc degeneration. METHODS An intravertebral staple acting on both the superior and inferior growth plates was inserted locally over T7-T9 of seven healthy immature pigs. Four age-matched animals served as controls. Radiographs were acquired monthly to assess induced spinal curvature and vertebral wedging (inverse model). Global (spinal) and local (vertebral, discal) geometric changes were evaluated over 3-months follow-up. Final left/right vertebral height differences were also quantified. RESULTS The only postoperative complication observed was one pig that had a persistent deep infection and was excluded from the study. No significant changes in spinal alignment were reported in control animals. Final induced Cobb angle was 25.0° ± 4.2° measured over T7-T9, with no observable sagittal profile modification. Highest vertebral wedging occurred at T9 with 18.2° ± 2.7°. Cumulative vertebral wedging over T7-T9 accounted for 45.4°, demonstrating evidence of reversed disc wedge phenomenon. Vertebral height was 3.9 ± 1.0 mm shorter on the instrumented side suggesting full growth restraint. Local and regional induced deformities significantly differed from their control counterparts (P < 0.001). CONCLUSION In this animal model, the local epiphyseal device achieved significant localized growth modulation over as little as three instrumented levels, with explicit vertebral wedging exclusive of the intervertebral disc. By increasing the number of instrumented levels, one may achieve higher curvature control potentially providing a unique local correction method to correct spinal deformity without affecting the intervertebral disc. LEVEL OF EVIDENCE 5.
Collapse
|