1
|
Brunken F, Mandelka E, Bullert B, Gruetzner PA, Vetter SY, Gierse J. Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction. BRAIN & SPINE 2024; 4:102769. [PMID: 38510605 PMCID: PMC10951758 DOI: 10.1016/j.bas.2024.102769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 01/29/2024] [Accepted: 02/16/2024] [Indexed: 03/22/2024]
Abstract
Introduction Fractures of the thoracolumbar junction are the most common vertebral fractures and can require surgical treatment. Several studies have shown that the accuracy of pedicle screw placement can be improved by the use of 3D-navigation. Still only few studies have focused on the use of navigation in traumatic spine injuries. Research question The aim of this study was to compare the screw placement accuracy and radiation exposure for 3D-navigated and fluoroscopy-guided percutaneous pedicle screw placement in traumatic fractures of the thoracolumbar junction. Materials and methods In this single-center study 25 patients undergoing 3D-navigated percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction (T12-L2) were compared to a control group of 25 patients using fluoroscopy. Screw accuracy was determined in postoperative CT-scans using the Gertzbein-Robbins classification system. Additionally, duration of surgery, dose area product, fluoroscopy time and intraoperative complications were compared between the groups. Results The accuracy of 3D-navigated percutaneous pedicle screw placement was 92.66 % while an accuracy of 88.08 % was achieved using standard fluoroscopy (p = 0.19). The fluoroscopy time was significantly less in the navigation group compared to the control group (p = 0.0002). There were no significant differences in radiation exposure, duration of surgery or intraoperative complications between the groups. Discussion and conclusion The results suggest that 3D-navigation facilitates higher accuracy in percutaneous pedicle screw placement of traumatic fractures of the thoracolumbar junction, although limitations should be considered. In this study 3D-navigation did not increase fluoroscopy time, while radiation exposure and surgery time were comparable.
Collapse
Affiliation(s)
- Fenna Brunken
- Research Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
- Heidelberg University, Grabengasse 1, 69117 Heidelberg, Germany
| | - Eric Mandelka
- Research Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
- Heidelberg University, Grabengasse 1, 69117 Heidelberg, Germany
| | - Benno Bullert
- Research Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
- Heidelberg University, Grabengasse 1, 69117 Heidelberg, Germany
| | - Paul Alfred Gruetzner
- Research Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
- Heidelberg University, Grabengasse 1, 69117 Heidelberg, Germany
| | - Sven Y. Vetter
- Research Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
- Heidelberg University, Grabengasse 1, 69117 Heidelberg, Germany
| | - Jula Gierse
- Research Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
- Heidelberg University, Grabengasse 1, 69117 Heidelberg, Germany
| |
Collapse
|
2
|
Lakomkin N, Eastlack RK, Uribe JS, Park P, Ryu SI, Kretzer R, Mimran RI, Holman P, Veeravagu A, Hassanzadeh H, Johnson MM, Sullivan L, Clark A, Mundis GM. An Integrated 3-Dimentional Navigation System Increases the Accuracy, Efficiency, and Safety of Percutaneous Thoracolumbar Pedicle Screw Placement in Minimally Invasive Approaches: A Randomized Cadaveric Study. Global Spine J 2024:21925682231224394. [PMID: 38165219 DOI: 10.1177/21925682231224394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2024] Open
Abstract
STUDY DESIGN Cadaveric study. OBJECTIVES The purpose of this study was to compare a novel, integrated 3D navigational system (NAV) and conventional fluoroscopy in the accuracy, efficiency, and radiation exposure of thoracolumbar percutaneous pedicle screw (PPS) placement. METHODS Twelve skeletally mature cadaveric specimens were obtained for twelve individual surgeons. Each participant placed bilateral PS at 11 segments, from T8 to S1. Prior to insertion, surgeons were randomized to the sequence of techniques and the side (left or right). Following placement, a CT scan of the spine was obtained for each cadaver, and an independent reviewer assessed the accuracy of screw placement using the Gertzbein grading system. Outcome metrics of interest included a comparison of breach incidence/severity, screw placement time, total procedure time, and radiation exposure between the techniques. Bivariate statistics were employed to compare outcomes at each level. RESULTS A total of 262 screws (131 using each technique) were placed. The incidence of cortical breaches was significantly lower with NAV compared to FG (9% vs 18%; P = .048). Of breaches with NAV, 25% were graded as moderate or severe compared to 39% in the FG subgroup (P = .034). Median time for screw placement was significantly lower with NAV (2.7 vs 4.1 min/screw; P = .012), exclusive of registration time. Cumulative radiation exposure to the surgeon was significantly lower for NAV-guided placement (9.4 vs 134 μGy, P = .02). CONCLUSIONS The use of NAV significantly decreased the incidence of cortical breaches, the severity of screw breeches, screw placement time, and radiation exposure to the surgeon when compared to traditional FG.
Collapse
Affiliation(s)
| | - Robert K Eastlack
- Department of Orthopaedic Surgery, Scripps Clinic, La Jolla, CA, USA
| | - Juan S Uribe
- Department of Neurosurgery, Barrow Neurological Institute, Phoenix, AZ, USA
| | - Paul Park
- Department of Neurosurgery, Semmes-Murphey Clinic, Memphis, TN, USA
| | - Stephen I Ryu
- Department of Neurosurgery, Sutter Health, Palo Alto, CA, USA
| | - Ryan Kretzer
- Department of Neurosurgery, Western Neuro, Phoenix, AZ, USA
| | - Ronnie I Mimran
- Department of Neurosurgery, Sutter Health, Palo Alto, CA, USA
| | - Paul Holman
- Department of Neurosurgery, Houston Methodist, Houston, TX, USA
| | - Anand Veeravagu
- Department of Neurosurgery, Stanford University, Palo Alto, CA, USA
| | - Hamid Hassanzadeh
- Department of Orthopaedic Surgery, University of Virginia, Charlottesville, VA, USA
| | - Michele M Johnson
- Department of Neurosurgery, Atlanta Brain and Spine, Atlanta, GA, USA
| | - Linda Sullivan
- Medical writing and Biostatistics, NuVasive, San Diego, CA, USA
| | - Aaron Clark
- Department of Neurosurgery, University of California, San Francisco, CA, USA
| | - Gregory M Mundis
- Department of Orthopaedic Surgery, Scripps Clinic, La Jolla, CA, USA
| |
Collapse
|
3
|
Rosa Filezio M, Peiro-Garcia A, Parsons DL, Thomas K, Ferri-de-Barros F. Accuracy of imaging grading in comparison to open laminectomy to evaluate pedicle screws positioning. Ann Med Surg (Lond) 2024; 86:199-206. [PMID: 38222761 PMCID: PMC10783280 DOI: 10.1097/ms9.0000000000001515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 11/05/2023] [Indexed: 01/16/2024] Open
Abstract
Study design Prospective experimental study. Objective To compare the accuracy of O-Arm-acquired radiographic and computed tomography (CT) evaluation of thoracic pedicle screw placement with open laminectomy in a simulation laboratory. Summary of background data Improving surgical safety and procedural efficiency during thoracic posterior spine instrumentation is essential for decreasing complication rates and possible related risks. The most common way of verifying the position of pedicle screws during the surgical procedure and immediately postoperatively is to acquire intraoperative fluoroscopic images and plain radiographs of the spine, respectively. Laboratory simulated surgery is a valuable tool to evaluate the accuracy of those exams. Methods Twenty simulation models of scoliosis from T3 to T7 were instrumented by five spine fellows (total of 200 pedicle screws), followed by radiographic and CT images acquired with the assistance of the O-Arm which were evaluated by three independent raters. A fellowship-trained spine neurosurgeon performed laminectomies on the instrumented levels and assessed pedicle integrity (gold standard). Results Forty-eight breaches were identified in the axial direct view after laminectomy. Of those, eighteen breaches were classified as unacceptable. Regarding the sagittal direct view, four breaches were observed, three of which were classified as unacceptable. Overall, both O-arm radiographic and CT evaluations had a significantly high negative predicted value but a low positive predicted value to identify unacceptable breaches, especially in the sagittal plane. The frequency of missed breaches by all three examiners was high, particularly in the sagittal plane. Conclusion Postoperative evaluation of pedicle screws using O-arm-acquired radiographic or CT images may underdiagnose the presence of breaches. In our study, sagittal breaches were more difficult to diagnose than axial breaches. Although most breaches do not have clinical repercussions, this study suggests that this modality of postoperative radiographic assessment may be inaccurate. Level of evidence 4.
Collapse
|
4
|
Zhu X, Shao Y, Lu Y, Sun J, Chen J. Comparison of pedicle screw fixation by four different posterior approaches for the treatment of type A thoracolumbar fractures without neurologic injury. Front Surg 2023; 9:1036255. [PMID: 36684127 PMCID: PMC9849555 DOI: 10.3389/fsurg.2022.1036255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Accepted: 11/30/2022] [Indexed: 01/07/2023] Open
Abstract
Purpose This study was designed to compare the pedicle screw fixation by four different posterior approaches for the treatment of type A thoracolumbar fractures without neurologic injury. Methods A total of 165 patients with type A thoracolumbar fractures without neurologic injury who received pedicle screw fixation by posterior approaches from February 2017 to August 2018 were enrolled in this study. They were further divided into the following four groups according to different posterior approaches: Open-C group (conventional open approach), Open-W group (Wiltse approach), MIS-F group (percutaneous approach with fluoroscopy guidance), and MIS-O group (percutaneous approach with O-arm navigation). The demographic data, clinical outcomes, and radiologic parameters were evaluated and compared among the four groups. Results There were no significant differences in age, gender, fracture segment, and follow-up time. The incision length, blood loss, hospital stay time, and VAS (Visual Analog Scale) and ODI (Oswestry Disability Index) scores at the early stage of post-operation were the worst in the Open-C group. The MIS-O group showed significantly higher accuracy rate of pedicle position than other groups. The preoperative and postoperative AVH (anterior vertebral height) and VWA (vertebral wedge angle) obtain obvious correction in all patients immediately after and 1 year post-operation. No difference was found among the four groups at the final radiographic follow-up. Conclusions The four different posterior approaches are effective in treating type A thoracolumbar fractures in our study. Each approach has its own individual strengths and weaknesses and therefore requires comprehensive consideration prior to use. Proper approaches selection is critical to patients.
Collapse
Affiliation(s)
- Xu Zhu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Yijie Shao
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Yun Lu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, China,Orthopedic Institute, Soochow University, Suzhou, China
| | - Jiajia Sun
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, China,Correspondence: Jie Chen Jiajia Sun
| | - Jie Chen
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, China,Correspondence: Jie Chen Jiajia Sun
| |
Collapse
|
5
|
Accuracy Assessment of Percutaneous Pedicle Screw Placement Using Cone Beam Computed Tomography with Metal Artifact Reduction. SENSORS 2022; 22:s22124615. [PMID: 35746396 PMCID: PMC9228786 DOI: 10.3390/s22124615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 06/10/2022] [Accepted: 06/16/2022] [Indexed: 11/16/2022]
Abstract
Metal artifact reduction (MAR) algorithms are used with cone beam computed tomography (CBCT) during augmented reality surgical navigation for minimally invasive pedicle screw instrumentation. The aim of this study was to assess intra- and inter-observer reliability of pedicle screw placement and to compare the perception of baseline image quality (NoMAR) with optimized image quality (MAR). CBCT images of 24 patients operated on for degenerative spondylolisthesis using minimally invasive lumbar fusion were analyzed retrospectively. Images were treated using NoMAR and MAR by an engineer, thus creating 48 randomized files, which were then independently analyzed by 3 spine surgeons and 3 radiologists. The Gertzbein and Robins classification was used for screw accuracy rating, and an image quality scale rated the clarity of pedicle screw and bony landmark depiction. Intra-class correlation coefficients (ICC) were calculated. NoMAR and MAR led to similarly good intra-observer (ICC > 0.6) and excellent inter-observer (ICC > 0.8) assessment reliability of pedicle screw placement accuracy. The image quality scale showed more variability in individual image perception between spine surgeons and radiologists (ICC range 0.51−0.91). This study indicates that intraoperative screw positioning can be reliably assessed on CBCT for augmented reality surgical navigation when using optimized image quality. Subjective image quality was rated slightly superior for MAR compared to NoMAR.
Collapse
|
6
|
Ohmori K, Terayama S, Ono K, Sakamoto M, Horikoshi Y. Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study. NORTH AMERICAN SPINE SOCIETY JOURNAL (NASSJ) 2022; 10:100121. [PMID: 35634131 PMCID: PMC9130105 DOI: 10.1016/j.xnsj.2022.100121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 05/04/2022] [Accepted: 05/04/2022] [Indexed: 11/25/2022]
Abstract
We compared the VIPER PRIME™ (VP) with existing percutaneous pedicle screw systems. Screw-placement accuracy was not inferior using VP compared with previous systems. Use of VP reduced the screw-insertion time and use of fluoroscopy. VP was not associated with any device- or treatment-related adverse events. VP could reduce radiation exposure and provide accurate pedicle screw placement.
Background Minimally invasive lumbar fusion has recently become a widely used technique worldwide. This randomized active controlled study was conducted to demonstrate the non-inferiority of the K-wireless Minimally Invasive Spine (MIS) Percutaneous Pedicle Screw (PPS) system compared with use of the six pedicle screw systems currently used in our practices with respect to the accuracy of pedicle screw placement.Also to compare the screw-insertion time and number of fluoroscopic observations during screw insertion between the groups. Methods A total of 80 patients with degenerative spinal diseases or vertebral fractures were assigned, including 41 patients in the K-wireless MIS PPS system group (K-wireless group) and 39 in the control group (K-wire group). The accuracy of the screw insertion, screw-insertion time, number of fluoroscopic observations during screw insertion, and the incidence of adverse events were compared between the K-wireless group and the K-wire group. The accuracy rate was calculated as the number of screws with no breach divided by the total number of screws. Results The accuracy rates of screw insertion were 85.7% and 75.0% in the K-wireless and K-wire groups, respectively, with an intergroup difference of 10.7% (95% confidence interval: 2.3–19.1%). The K-wireless group demonstrated non-inferiority compared with the K-wire group. The mean screw-insertion time was significantly shorter in the K-wireless group (2.62 and 2.97 min in the K-wireless and K-wire groups, respectively; P=0.005). There were also significantly fewer fluoroscopies in the K-wireless group (10.7 and 17.4 in the K-wireless and K-wire groups, respectively; P<0.001). There were no device-related or study treatment-related adverse events in either group. Conclusions The accuracy of pedicle screw insertion using the K-wireless MIS PPS system was not inferior to that of existing products. In terms of safety, no product-related or treatment-related adverse events were identified in this study and no new safety concerns were noted.
Collapse
|