1
|
Drummond I, Durand-Hill M, Jones N, O'Hagan PJ, Edwards D. Systematic review: dorsal bridge plating in distal radius fractures. Musculoskelet Surg 2024; 108:359-366. [PMID: 38967772 PMCID: PMC11371870 DOI: 10.1007/s12306-024-00822-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 05/03/2024] [Indexed: 07/06/2024]
Abstract
PURPOSE Distal radius fractures are the most common upper limb fractures in adults (up to 18% of all fractures in the Emergency Department). Conservative management is possible for the majority, the preferred surgical technique being volar plate fixation. Dorsal bridge plating (DBP) is an alternative method of treatment for complex fractures. DBP acts as an internal fixator and can be used in patients needing early rehabilitation. This systematic review assesses the demographics, functional and radiological outcomes and complications of using DBP in patients with distal radius fractures compared to volar plate fixation. METHODS A literature search of PubMed, Cochrane, EMBASE and Google Scholar was performed according to PRISMA guidelines. Seven hundred and sixty-one articles were found; 11 articles met the inclusion criteria. Cadaveric studies and case studies of less than five patients were excluded. Primary outcome measures were functional and radiological outcomes. Complications were recorded as secondary outcomes. RESULTS Three hundred and ninety-four patients were included in the study with an average age of 54.8 years (53.9% male and 46.1% female). Weighted mean follow-up was 55.2 weeks; the mean time to plate removal was 17.3 weeks with a mean DASH score of 25.7. The weighted range of movement was 46.9° flexion, 48.8° extension, 68.4° pronation and 67.5° supination. The radiological parameters show satisfactory outcomes with a mean radial height of 10mm, volar tilt of 3.1°, ulnar variance of 0.5mm and radial inclination of 18.8°. The complication rate was 11.4%. Digital stiffness was the most common complication but improved if tenolysis was performed at plate removal. CONCLUSIONS DBP is a good alternative to volar plating for complex distal radius fractures. The functional outcomes showed a slight loss of range of movement, whereas the radiological outcomes were within recommended limits. A significant disadvantage of the plate is the need for further surgical removal.
Collapse
Affiliation(s)
- I Drummond
- Royal London Hospital, Barts Health NHS Trust, London, UK.
| | - M Durand-Hill
- Royal London Hospital, Barts Health NHS Trust, London, UK
| | - N Jones
- Royal London Hospital, Barts Health NHS Trust, London, UK
| | - P J O'Hagan
- Royal London Hospital, Barts Health NHS Trust, London, UK
| | - D Edwards
- Royal London Hospital, Barts Health NHS Trust, London, UK
- Centre for Neuroscience, Surgery and Trauma within Blizard Institute, Queen Mary University of London, London, UK
| |
Collapse
|
2
|
Vivace BJ, Garlapaty AR, Reeves E, Bezold W, London DA. Adjunctive Dorsal Spanning Plate Fixation in the Stabilization of Perilunate Dislocations. J Hand Surg Am 2024:S0363-5023(24)00208-9. [PMID: 38934992 DOI: 10.1016/j.jhsa.2024.04.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 03/09/2024] [Accepted: 04/03/2024] [Indexed: 06/28/2024]
Abstract
PURPOSE To compare the biomechanical properties of adjunctive dorsal spanning plate (DSP) fixation with traditional K-wire fixation of perilunate dislocations in a cadaveric model. METHODS Fourteen fresh-frozen cadaveric wrists underwent simulated perilunate injury. The specimens were randomly allocated to either K-wire fixation versus K-wire and DSP fixation. Scapholunate (SL) ligament repair was performed in all specimens. The constructs were tested using a robot cyclically and to failure. Fluoroscopic images were obtained of the specimens prior to simulated injury, after fixation, after 10 and 100 loading cycles, and at construct failure. Differences in carpal alignment parameters (SL interval, SL angle, lunotriquetral interval, and capitolunate angle) and load to failure were recorded. RESULTS There were no statistically significant differences between the two group's carpal alignment parameters after fixation. Specimens fixated with K-wires and DSP required significantly higher loads to achieve construct failure. The only significant difference between the two groups' carpal alignment parameters was SL interval change at failure. CONCLUSIONS Compared with K-wire fixation alone, adjunctive DSP fixation resulted in significantly increased loads to failure and decreased change in SL interval at the time of failure. CLINICAL RELEVANCE Adjunctive DSP may be a useful technique in the polytraumatized patient in whom providing back a weight-bearing extremity may be advantageous in the rehabilitation process.
Collapse
Affiliation(s)
- Bradley J Vivace
- Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, University of Missouri, Columbia, MO.
| | - Ashwin R Garlapaty
- Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, University of Missouri, Columbia, MO
| | - Evan Reeves
- Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, University of Missouri, Columbia, MO
| | - Will Bezold
- Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, University of Missouri, Columbia, MO
| | - Daniel A London
- Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, University of Missouri, Columbia, MO
| |
Collapse
|
3
|
Emmert AS, Swenson AK, Matar RN, Ross PR, Stern PJ. Characterization of Major Complications of Bridge Plating of Distal Radius Fractures at a Level I Trauma Center. Hand (N Y) 2024:15589447241257964. [PMID: 38869067 DOI: 10.1177/15589447241257964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/14/2024]
Abstract
BACKGROUND Comminuted, markedly displaced distal radius fractures can cause instability requiring advanced stabilization with dorsal bridge plating. However, published complication rates of bridge plating widely vary. We hypothesize that complications of bridge plating of distal radius fractures are more prevalent than published rates. METHODS A retrospective review was performed on all patients at an academic level I trauma center treated with a bridge plate for a distal radius fracture from 2014 to 2022. RESULTS Sixty-five wrists were included in the final analysis: average age 53 years, male 51%, average plate retention 4 months, and average follow-up 6 months. Carpal tunnel release (CTR) was performed at time of primary procedure in 7 (10%) cases. Radial height, radial inclination, dorsal tilt, and ulnar variance were all significantly improved (P < .001). Grip strength, flexion, extension, and supination were significantly limited (P < .03). Twenty-one patients (32%) developed 35 major complications requiring unplanned reoperation, including mechanical hardware-related complication (15%), deep infection (11%), nonunion/delayed union (9%), adhesions (6%), median neuropathy (6%), symptomatic arthritis (5%), and tendon rupture (2%). Plate breakage occurred in 3 patients (5%) and was always localized over the central drill holes of the bridge plate. CONCLUSIONS Major complications for bridge plating of distal radius fractures were higher at our institution than previously published. Plate breakage should prompt reconsideration of plate design to avoid drill holes over the wrist joint. Signs and symptoms of carpal tunnel syndrome should be carefully assessed at initial presentation, and consideration for concomitant CTR should be strongly considered.
Collapse
Affiliation(s)
| | - Alan K Swenson
- Orthopedic Physicians Alaska, OrthoAlaska, Anchorage, USA
| | | | | | - Peter J Stern
- University of Cincinnati College of Medicine, OH, USA
| |
Collapse
|
4
|
Esworthy GP, Shaji V, Duraku L, Wu F, Power DM. Bridge Plate Distraction for Complex Distal Radius Fractures: A Cohort Study and Systematic Review of the Literature. J Wrist Surg 2024; 13:282-292. [PMID: 38808186 PMCID: PMC11129887 DOI: 10.1055/s-0043-1770791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 05/22/2023] [Indexed: 05/30/2024]
Abstract
Background Dorsal bridge plating (DP) of the distal radius is used as a definitive method of stabilization in complex fracture configurations and polytrauma patients. Questions/Purposes This review aims to summarize the current understanding of DP and evaluate surgical outcomes. Methods Four databases were searched following the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines and registered with PROSPERO. Papers presenting outcome or complication data for DP were included. These were reviewed using the National Institutes of Health Quality Assessment and Methodological Index for Non-Randomised Studies tools. Results were collated and compared to a local cohort of DP patients. Results Literature review identified 416 patients with a pooled complication rate of 17% requiring additional intervention. The most prevalent complications were infection/wound healing issues, arthrosis, and hardware failure. Average range of motion was flexion 46.5 degrees, extension 50.7 degrees, ulnar deviation 21.4 degrees, radial deviation 17.3 degrees, pronation 75.8 degrees, and supination 72.9 degrees. On average, DP removal occurred at 3.8 months. Quality assessment showed varied results. There were 19 cases in our local cohort. Ten displayed similar results to the systematic review in terms of range of motion and radiographic parameters. Higher QuickDASH scores and complication rates were noted. Local DP showed earlier plate removal at 2.9 months compared to previous studies. Conclusion DP is a valid and useful technique for treating complex distal radius fractures. It displays a lower risk of infection and pain compared to external fixation which is commonly used to treat similar injuries. Patients can recover well following treatment both in function and range of motion. Further high-quality studies are required to fully evaluate the technique.
Collapse
Affiliation(s)
- George P. Esworthy
- Birmingham Hand Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Untied Kingdom
- Leicester Medical School, University of Leicester, Leicester, United Kingdom
| | - Vibha Shaji
- Leicester Medical School, University of Leicester, Leicester, United Kingdom
| | - Liron Duraku
- Birmingham Hand Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Untied Kingdom
- Department of Plastic, Reconstructive and Hand Surgery, Amsterdam UMC, Amsterdam, Netherlands
| | - Feiran Wu
- Birmingham Hand Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Untied Kingdom
| | - Dominic M. Power
- Birmingham Hand Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Untied Kingdom
| |
Collapse
|
5
|
Shah HA, Martin AR, Geller JS, Iyer H, Dodds SD. Radiographic Outcomes following K-Wire Augmentation of Dorsal Spanning Plate Fixation for Intra-Articular Fractures of the Distal Radius. J Wrist Surg 2022; 11:388-394. [PMID: 36339083 PMCID: PMC9633136 DOI: 10.1055/s-0041-1740401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 10/22/2021] [Indexed: 12/25/2022]
Abstract
Background Restoration of articular surface alignment is critical in treating intra-articular distal radius fractures. Dorsal spanning plate fixation functions as an internal distraction mechanism and can be advantageous in the setting of highly comminuted fracture patterns, polytrauma patients, and patients with radiocarpal instability. The addition of K-wires to support articular surface reduction potentially augments fracture repair stability. Questions/Purposes We examined the radiographic outcomes and maintenance of reduction in patients with comminuted intra-articular distal radius fractures treated with K-wire fixation of articular fragments followed by dorsal spanning plate application. Patients and Methods We reviewed 35 consecutive patients with complex intra-articular distal radius fractures treated with dorsal spanning plate and K-wire fixation between April 2016 and October 2019. AO classification was recorded: B1 (3), B3 (2), C2 (2), C3 (28). A two-tailed paired t -test was used to compare findings immediately post-dorsal spanning plate surgery and at final follow-up after dorsal spanning plate removal. Results Mean patient age was 43.3 years (19-78 years). Mean follow-up was 7.8 months (SD 4.3 months) from surgery and 2.5 months from pin removal (SD 2.6 months). All patients achieved radiographic union. Radial height (mean interval change (MIC) 0.2 mm, SD 2.2, p = 0.63), articular step-off (MIC 0.1 mm, SD 0.6 mm, p = 0.88), and radial inclination (MIC -1.1 degrees, SD 3.7 degrees, p = 0.10) did not change from post-surgery to final follow-up. Ulnar variance (MIC -0.9 mm, SD 2.0 mm, p = 0.02) and volar tilt (MIC -1.5 degrees, SD 4.4 degrees, p = 0.05) were found to have decreased. Conclusion Dorsal spanning plate augmented with K-wire fixation for comminuted intra-articular distal radius fractures in polytrauma patients allows for immediate weightbearing and maintains articular surface alignment at radiographic union and may provide better articular restoration than treatment with dorsal spanning plate alone. Level of Evidence This is a Level IV , therapeutic study.
Collapse
Affiliation(s)
- Harsh A. Shah
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| | - Anthony R. Martin
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| | - Joseph S. Geller
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| | - Hariharan Iyer
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| | - Seth D. Dodds
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| |
Collapse
|
6
|
Nguyen DM, Boden AL, Allen MK, John T, Knoll GM, Dodds SD. Dorsal Spanning Plate for Perilunate Dislocations. J Wrist Surg 2022; 11:16-20. [PMID: 35127259 PMCID: PMC8807102 DOI: 10.1055/s-0041-1729634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 03/22/2021] [Indexed: 10/21/2022]
Abstract
Purpose The purpose of this study was to compare radiographic outcomes in patients treated with the traditional method of open reduction, internal fixation (ORIF) and casting as compared with those treated with ORIF and dorsal spanning plate (DSP) fixation. We hypothesized that the application of a DSP to augment the repair of perilunate dislocations would maintain carpal stability while also allowing early loadbearing through the carpus. Materials and Methods This is a retrospective radiographic review of patients with a perilunate dislocation, who were treated with ORIF and casting or ORIF with a dorsal spanning plate between 2012-2018. Scapholunate (SL) and lunotriquetral (LT) intervals were measured immediately after the index surgery and after scheduled hardware removal. A total of 28 patients met inclusion criteria, including 13 cases with traditional treatment and 15 cases with dorsal spanning plate fixation. Results Comparison of the change in SL interval and LT interval between the 13 patients in the traditional treatment group and the 15 patients in the DSP group did not yield any clinically relevant variation after statistical analysis. Both groups demonstrated minimal change in the radiographic markers of carpal stability from postoperative radiographs obtained immediately after the index repair and after the removal of hardware. Conclusion DSP fixation placed at the index surgery with early loadbearing for the treatment of perilunate dislocation is not inferior to the current mainstay of treatment consisting of cast immobilization without loadbearing and does not confer any increased carpal instability in comparison to ORIF and casting.
Collapse
Affiliation(s)
- Duc M. Nguyen
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| | - Allison L. Boden
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| | - Megan K. Allen
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| | - Tamara John
- Department of Orthopedics and Rehabilitation, Yale School of Medicine, New Haven, Connecticut
| | - Greg M. Knoll
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| | - Seth D. Dodds
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida
| |
Collapse
|
7
|
Labrum JT, Ilyas AM. Bridge Plate Fixation of Distal Radius Fractures: Indications, Techniques, and Outcomes. Orthopedics 2021; 44:e620-e625. [PMID: 34292828 DOI: 10.3928/01477447-20210618-26] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Distal radius fractures are among the most commonly encountered injuries treated by orthopedic surgeons. The incidence of distal radius fractures appears to be on the rise. Although this injury is usually treated nonoperatively, surgical management is often indicated and involves several options, including percutaneous pinning, fragment-specific fixation, volar/dorsal/radial locked plating, intramedullary fixation, and external fixation. More recently, dorsal spanning bridge plating has been introduced for certain fracture patterns and patient circumstances. This article reviews the indications, surgical techniques, outcomes, and potential complications associated with bridge plating of distal radius fractures. The authors believe that this article will familiarize surgeons with an additional surgical technique that can be used to treat complex presentations of a common orthopedic injury. [Orthopedics. 2021;44(4):e620-e625.].
Collapse
|
8
|
Distal Radius Fractures and the Dorsal Spanning Plate in the Management of the Polytraumatized Patient. J Orthop Trauma 2021; 35:s6-s10. [PMID: 34415875 DOI: 10.1097/bot.0000000000002204] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/08/2021] [Indexed: 02/02/2023]
Abstract
Distal radius fractures are some of the most common fractures treated by the orthopaedic surgeon. There are a variety of methods of fixation to treat these fractures; however, in patients with polytrauma and in high-energy fracture patterns, fixation options can be limited. In the past, these fractures were treated with plaster, Kirschner wires, or external fixators that were fraught with complications. The dorsal spanning plate is an excellent option in the treatment of high-energy fractures and patients with polytrauma, fractures with dorsal or volar comminution, fracture dislocations, and shear injuries, and in geriatric patients with poor bone quality. The dorsal spanning plate not only allows for fixation of these complex fractures but also allows for weight-bearing through the wrist, an advantage for patients with concomitant lower extremity fractures and geriatric patients who need mobility aides. Understanding the risks and benefits of dorsal spanning plates and their use for the treatment of polytraumatized patient is a vital base of knowledge for the orthopaedic traumatologist.
Collapse
|
9
|
Fares AB, Childs BR, Polmear MM, Clark DM, Nesti LJ, Dunn JC. Dorsal Bridge Plate for Distal Radius Fractures: A Systematic Review. J Hand Surg Am 2021; 46:627.e1-627.e8. [PMID: 33573844 DOI: 10.1016/j.jhsa.2020.11.026] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 09/20/2020] [Accepted: 11/24/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE This study presents patient demographics, injury characteristics, outcomes, and complications associated with dorsal bridge plating (DBP) in the treatment of distal radius fractures. METHODS A literature search performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines identified 206 articles, 12 of which met inclusion criteria, accounting for 310 patients. Included articles contained the results of DBP for treatment of distal radius fractures with reported outcomes between 1988 and 2018. Data were pooled and analyzed focusing on patient demographics, as well as 3 primary outcomes of complications, range of motion (ROM), and Disabilities of the Arm, Shoulder, and Hand (DASH) and QuickDASH scores. RESULTS Average age was 55 years, median follow-up was 24 months, and the most common use was in comminuted (92%) intra-articular (92%) distal radius fracture caused by fall (58%), or motor vehicle collision or motorcycle collision (27%). A minority of patients had open fractures (16%) and most were cases of polytrauma (65%). Median time from placement to DBP removal was 17 weeks (mean, 119 days). At final follow-up, mean wrist ROM was 45° flexion, 50° extension, 75° pronation, and 73° supination. Mean DASH score was 26.1, and mean QuickDASH score was 19.8. The overall rate for any complication was 13%; the most common was hardware failure (3%) followed by symptomatic malunion or nonunion (3%), and persistent pain after hardware removal (2%). CONCLUSIONS Dorsal bridge plating was found to be used most commonly in intra-articular, comminuted distal radius fractures with overall functional wrist ROM, moderate patient-reported disability, and a 13% complication rate at follow-up. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic IV.
Collapse
Affiliation(s)
- Austin B Fares
- Department of Orthopaedic Surgery, William Beaumont Army Medical Center, El Paso, TX.
| | - Benjamin R Childs
- Department of Orthopaedic Surgery, William Beaumont Army Medical Center, El Paso, TX
| | - Michael M Polmear
- Department of Orthopaedic Surgery, William Beaumont Army Medical Center, El Paso, TX
| | - DesRaj M Clark
- Department of Clinical and Experimental Orthopaedics, Walter Reed National Military Medical Center, Bethesda, MD
| | - Leon J Nesti
- Department of Clinical and Experimental Orthopaedics, Walter Reed National Military Medical Center, Bethesda, MD
| | - John C Dunn
- Department of Orthopaedic Surgery, William Beaumont Army Medical Center, El Paso, TX
| |
Collapse
|
10
|
The spanning plate as an internal fixator in complex distal radius fractures: a prospective cohort study. Eur J Trauma Emerg Surg 2021; 48:2369-2377. [PMID: 34185106 DOI: 10.1007/s00068-021-01738-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 06/19/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Minimal invasive temporary spanning plate (SP) fixation of the wrist has been described as an alternative treatment method in complex distal radius fractures (DRFs). The purpose of this study is to conduct an outcome analysis of all consecutive DRFs treated by SP fixation representing the so far largest published patient cohort outside the United States. METHODS Indication for SP fixation include DRFs with severe metaphyseal comminution, radiocarpal fracture dislocations with concomitant ligamentous injuries and very distal intra-articular fractures lacking the possibility of adequate plate anchoring. All consecutive patients undergoing SP fixation of DRFs were prospectively included in a single level I trauma centre between 01/01/2018 and 31/12/2020. For functional and patient-rated outcome analysis only patients who completed the 12 month follow-up were included. RESULTS In the mentioned timeframe, a total of 562 DRFs were treated operatively of which 28 underwent SP fixation. Average age was 58.1 years (range 22-95 years). The fracture type ranged from AO/OTA type B1.1 to C3.3 and included 8 fracture dislocations. SP removal was performed on average 3.7 months after the initial operation (range 1.4-6.5 months). Twenty-five patients completed the 12 month follow-up (mean 14.5 months, range 12-24). Radiological evidence of fracture healing appeared on average 9.9 weeks (range 5-28 weeks) after the initial operation. One patient experienced asymptomatic non-union. Mean radial inclination, volar tilt and ulnar variance at 1 year were all within the acceptable limit predictive of symptomatic malunion. Complications included two patients with tendon rupture and one patient with extensor tendon adhesions needing tenolysis at the time of plate removal leaving an overall complication rate of 12%. There was no implant failure and no infection. Mean satisfaction score was 8.3 (range 4-10) and mean visual analogue scale for resting pain was 0.8 (range 0-5). The mean PRWE score was 17.9 (range 0-59.5) and the mean DASH score was 16.6 (range 0-60.8). Grip strength averaged 23 kg (range 4-74 kg) amounting to 68% of the opposite side. Range of motion regarding the extension/flexion, radial/ulnar abduction and pronation/supination arc reached 72%, 77% and 95% compared to the unaffected side, respectively. CONCLUSIONS The radiological, functional and patient-rated outcomes in this study are remarkably good considering the complexity of the included fractures. Therefore, this method represents a valuable alternative for the treatment of complex DRFs in selected patients.
Collapse
|
11
|
Henry TW, Tulipan JE, McEntee RM, Beredjiklian PK. Early Retrieval of Spanning Plates Used for Fixation of Complex Fractures of the Distal Radius. J Wrist Surg 2021; 10:229-233. [PMID: 34109066 PMCID: PMC8169165 DOI: 10.1055/s-0040-1722573] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 11/27/2020] [Indexed: 10/22/2022]
Abstract
Background Spanning plates are being increasingly used for the treatment of complex fractures of the distal radius. The traditional recommendation is to leave the hardware in place for at least 12 weeks. Questions/Purpose This study assesses the comparative outcomes of spanning plates removed at or before 10 weeks. We hypothesized that acceptable healing and functional outcomes can be achieved with earlier hardware removal to allow for earlier range of motion, rehabilitation, and return to function. Patients and Methods All patients treated for a comminuted, intra-articular distal radius fracture with a temporary spanning plate were identified. Outcomes of bridge plates removed before 10 weeks were compared with plates removed after 12 weeks. Twenty patients in the short duration cohort were compared with 40 patients in the long duration cohort. Results All fractures healed and there were 10 complications (4 short duration, 6 long duration) and 2 reoperations (1 short duration, 1 long duration) in the study population. There were no significant differences in final Quick-DASH scores (27.4 short duration, 20.9 long duration) or radiographic alignment. Mean values for wrist extension and ulnar deviation were significantly worse in the long duration cohort, although these differences are of unclear clinical significance. Conclusion It may be safe to remove spanning bridge plates earlier than what is traditionally recommended. Plate removal at or before 10 weeks did not detract from healing or radiographic alignment. Prospective investigations assessing the optimal duration of fixation for this technique are needed. Level of Evidence This is a Level IV study.
Collapse
Affiliation(s)
- Tyler W. Henry
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Jacob E. Tulipan
- Department of Hand and Wrist Surgery, Rothman Orthopaedic Institute, Philadelphia, Pennsylvania
| | - Richard M. McEntee
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Pedro K. Beredjiklian
- Department of Hand and Wrist Surgery, Rothman Orthopaedic Institute, Philadelphia, Pennsylvania
| |
Collapse
|
12
|
Abstract
There are several options for plate fixation of distal radius fractures. Volar plating has broad applicability and consistent outcomes, and thus is the most commonly used plate type. Dorsal plates are advantageous for specific fracture patterns, and can provide direct fracture reduction and buttressing, but may be prominent and can cause tendon irritation. Bridge plates offer an alternative to external fixation while avoiding the complications with prominent hardware, because they span highly comminuted fractures and can be used for immediate weight bearing; however, they require plate removal. Choice of plate fixation should depend on fracture type, patient factors, and surgeon experience.
Collapse
|
13
|
Temporary spanning plate wrist fixation of complex distal radius fractures: a systematic review of 353 patients. Eur J Trauma Emerg Surg 2021; 48:1649-1662. [PMID: 33900417 DOI: 10.1007/s00068-021-01656-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Accepted: 03/21/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE Temporary spanning plate fixation of the wrist has been described as an alternative treatment method for complex distal radius fractures (DRfs). This systematic review aims to gain insight on clinical and radiological outcomes of this technique currently published in literature. METHODS A comprehensive literature search of Pubmed, Embase, CENTRAL and CINAHL databases was conducted on November 5th 2020. All studies reporting on complications, functional, patient-rated and radiological outcomes of temporary spanning plate wrist fixation of DRFs in adult patients were included. RESULTS Two prospective and eight retrospective cohort studies were included encompassing 353 patients with of 357 DRFs. The overall mean age was 53 years (range 19-95 years). Overall mean follow-up ranged from 6 months to 8.8 years. The union rate was 99.4%. Plate removal was performed on average 4.5 months after initial operation (range 1.1-28.9 months). The most frequently reported complication was implant failure with an incidence of 3.1%. Mean flexion/extension, pronation/supination and radial/ulnar inclination arc averaged 96.6°, 151.5° and 36.5°, respectively. Grip strength averaged 79.7% of the contralateral side. Mean DASH and PRWE scores were 22.9 and 16 points, respectively. Radiological indices were all within the acceptable limits. CONCLUSIONS Temporary spanning plate wrist fixation is a safe method for the treatment of complex DRFs. This technique can exploit the advantages of temporary wrist immobilization without the disadvantages of external fixation. With these aspects in mind, the spanning plate can serve as a valuable tool in the treatment of complex intra-articular DRFs.
Collapse
|
14
|
Role of a spanning plate as an internal fixator in complex distal radius fractures. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2020; 33:77-88. [PMID: 33245372 DOI: 10.1007/s00064-020-00686-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 06/11/2019] [Accepted: 07/19/2019] [Indexed: 10/22/2022]
Abstract
OBJECTIVE Minimally invasive temporary internal wrist arthrodesis as an alternative treatment method in complex distal radius fractures. INDICATIONS Complex distal radius fractures with dorsal and/or palmar comminution and little to no reconstruction possibilities, radiocarpal ligamentous injury, need for early weight bearing through the affected wrist (walking aids). CONTRAINDICATIONS Complex hand injuries limiting the possibility to safely secure the plate at either the metacarpal or the radial shaft. SURGICAL TECHNIQUE Percutaneous or open reduction and fixation of the distal radius fracture. Determine the location for the two stab incisions under fluoroscopy; one over the distal radial diaphysis and one over the second or third metacarpal. A third incision over Lister's tubercle allows transposition of the extensor pollicis longus (EPL) tendon, excision of the posterior interosseous nerve and dorsal arthrotomy. Retrograde insertion of the spanning plate. Placement of a first nonlocking screw through the glide hole into the metacarpal shaft. Under traction, a proximal screw hole is filled with a nonlocking screw into the radial diaphysis. Tightening of the cortical screws under lateral fluoroscopic view. The remaining screw holes at both the distal and proximal ends of the plate are filled with locking screws. Layered wound closure. POSTOPERATIVE MANAGEMENT A removable wrist splint is worn during 2 weeks. Weight bearing through the injured wrist is immediately allowed. Removal of the spanning plate is scheduled at 3 months after radiographic evidence of fracture consolidation. RESULTS In total, twelve distal radius fractures were treated by dorsal spanning plate fixation between January 2018 and January 2019. Average age was 53.3 ± 24.5 years (range 22-95 years). Both 3.5 mm and 2.4/2.7 mm plates were used. All twelve fractures were healed after 3 months. The mean Disabilities of Arm, Shoulder and Hand (DASH) score was 36.4 (range 8.3-70.0). There was one EPL tendon rupture, one case with extensor tendon adhesions, one periosteosynthetic fracture of the radial shaft and one complex regional pain syndrome. There was no implant failure and no infection.
Collapse
|
15
|
Wang WL, Ilyas AM. Dorsal Bridge Plating versus External Fixation for Distal Radius Fractures. J Wrist Surg 2020; 9:177-184. [PMID: 32257622 PMCID: PMC7113002 DOI: 10.1055/s-0039-1694063] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Accepted: 06/25/2019] [Indexed: 10/26/2022]
Abstract
Background External fixation and dorsal bridge plating are wrist spanning fixation options for distal radius fractures; however, their comparative effectiveness is not well understood. A meta-analysis was conducted to compare the clinical outcomes between these two techniques. Materials and Methods A PubMed database query of all distal radius fracture cases managed with spanning external fixation or dorsal bridge plating was performed. A total of 28 articles met inclusion criteria, yielding 895 patients for data extraction and comparative analysis. Results Dorsal bridge plating demonstrated lower rates of infection (2 vs. 10%, p = 0.05) and complex regional pain syndrome (1 vs. 4%, p = 0.04) but higher rates of hardware failure (4 vs. 1%, p = 0.026). Bridge plating also demonstrated higher rates of excellent/good ratings under the Gartland and Werley outcome score (91 vs. 83%, p = 0.016). There was no significant difference in DASH (Disability of the Arm, Shoulder, and Wrist) scores, radiographic parameters, or unplanned reoperations between the two spanning fixation options. Conclusion Bridge plating and external fixation both appear to be comparable for spanning fixation constructs for distal radius fractures, but with bridge plating having a potentially lower complication profile.
Collapse
Affiliation(s)
- William L. Wang
- Department of Orthopaedic Surgery, Thomas Jefferson University and the Rothman Institute, Philadelphia, Pennsylvania
| | - Asif M. Ilyas
- Department of Orthopaedic Surgery, Thomas Jefferson University and the Rothman Institute, Philadelphia, Pennsylvania
| |
Collapse
|
16
|
Guerrero EM, Lauder A, Federer AE, Glisson R, Richard MJ, Ruch DS. Metacarpal Position and Lunate Facet Screw Fixation in Dorsal Wrist-Spanning Bridge Plates for Intra-Articular Distal Radial Fracture: A Biomechanical Analysis. J Bone Joint Surg Am 2020; 102:397-403. [PMID: 31904607 DOI: 10.2106/jbjs.19.00769] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND A dorsal wrist-spanning plate (DWSP) can be affixed to the second or third metacarpal, depending on the morphology of the distal radial fracture (DRF) and on surgeon preference, but comparative biomechanical analyses between these methods are limited. This biomechanical study compared fixation to the second metacarpal versus the third metacarpal as measured by lunate facet fragment displacement in a cadaveric model of an axially loaded intra-articular DRF. The construct rigidity with the addition of an intrafragmentary lunate facet locking screw was also evaluated. METHODS A sample size of 14 cadaveric matched pairs was calculated to achieve 81.7% power. The 28 limbs were randomized to DWSP fixation to the second metacarpal (Group 1) or third metacarpal (Group 2); each wrist underwent an osteotomy simulating an unstable intra-articular DRF. Limbs were tested at axial loads of 50, 100, 150, 200, 250, and 300 N. Lunate facet displacement from the metaphyseal fragment at each load was measured with use of differential variable reluctance transducers. After initial testing, a locking screw was placed through the plate into the lunate facet fragment in the third metacarpal group (Group 3). Displacement measurements were repeated for all loads. Paired 2-tailed t tests with Bonferroni correction (significance, p < 0.008) were performed to assess differences in fragment stability between groups. RESULTS The average fracture displacement at 300 N was 0.8 mm in Group 1, 0.4 mm in Group 2, and 0.2 mm in Group 3. Plating to the third metacarpal more effectively resisted displacement compared with the second metacarpal at all axial loads (p < 0.008). The addition of a lunate facet screw further stiffened the construct at loads of ≥200 N (p < 0.008). CONCLUSIONS Plate fixation to the third metacarpal with an intrafragmentary screw was the most biomechanically favorable construct, although other factors may favor an alternative distal fixation site. Mean displacement of the lunate facet fragment at 300 N was <1 mm in all groups. CLINICAL RELEVANCE The present study demonstrated that a DWSP affixed to the third metacarpal with an intrafragmentary screw provides the most effective stabilization of the lunate facet fragment in intra-articular DRFs. This study validates the use of intrafragmentary screws to increase stability in DWSP fixation.
Collapse
Affiliation(s)
- Evan M Guerrero
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Alexander Lauder
- Department of Orthopaedic Surgery, Denver Health Medical Center, Denver, Colorado
| | - Andrew E Federer
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Richard Glisson
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Marc J Richard
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - David S Ruch
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| |
Collapse
|
17
|
Vakhshori V, Alluri RK, Stevanovic M, Ghiassi A. Review of Internal Radiocarpal Distraction Plating for Distal Radius Fracture Fixation. Hand (N Y) 2020; 15:116-124. [PMID: 30003802 PMCID: PMC6966280 DOI: 10.1177/1558944718787877] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Internal radiocarpal distraction plating is a versatile tool in the treatment of distal radius fractures that are not amenable to nonoperative treatment or operative fixation with standard volar or dorsal implants. Internal distraction plates may also be indicated in the setting of polytrauma or osteopenic bone. The plate functions as an internal fixator, using ligamentotaxis to restore length and alignment while providing relative stability for bony healing. The plate can be fixed to either the second or the third metacarpal, and anatomic and biomechanical studies have assessed the strengths and weaknesses of each strategy. This operative fixation technique leads to acceptable radiographic results and functional outcomes. Following fracture union, the plate is removed, and wrist range of motion is resumed.
Collapse
Affiliation(s)
- Venus Vakhshori
- Keck Medical Center at the University of
Southern California, Los Angeles, USA
| | - Ram Kiran Alluri
- Keck Medical Center at the University of
Southern California, Los Angeles, USA,Ram Kiran Alluri, Department of Orthopaedic
Surgery, Keck Medical Center at the University of Southern California, 1520 San
Pablo Street, #2000, Los Angeles, CA 90033, USA.
| | - Milan Stevanovic
- Keck Medical Center at the University of
Southern California, Los Angeles, USA
| | - Alidad Ghiassi
- Keck Medical Center at the University of
Southern California, Los Angeles, USA
| |
Collapse
|
18
|
Sharareh B, Mitchell S. Radiographic Outcomes of Dorsal Spanning Plate for Treatment of Comminuted Distal Radius Fractures in Non-Elderly Patients. JOURNAL OF HAND SURGERY GLOBAL ONLINE 2019; 2:94-101. [PMID: 35415482 PMCID: PMC8991644 DOI: 10.1016/j.jhsg.2019.10.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Accepted: 10/03/2019] [Indexed: 11/29/2022] Open
Abstract
Purpose Multifragmentary fractures of the distal radius with articular and metaphyseal comminution (AO 23-C3) represent challenging injuries to manage. Distal fracture lines, articular comminution, and limited distal bone stock may preclude stable fixation with a volar locking plate. The use of a dorsal spanning plate (DSP) offers an alternative treatment option in this setting. We examined the radiographic outcomes of a consecutive series of patients with comminuted intra-articular distal radius fractures not amenable to volar locked plating, who were treated with a DSP. Methods We reviewed all distal radius fractures treated with a dorsal spanning plate at our institution between October, 2014 and March, 2018. Patients with AO 23-C3 fractures treated with dorsal spanning plate fixation were included in this study. Demographic data, time from plate placement to removal, and postoperative radiographic outcomes were examined. Results We identified 24 patients, mean age 41 years (range, 19-62 years). Mean follow-up was 19.5 weeks (range, 12-35 weeks) from the time of plate placement. Plates were removed at a mean of 87 days (range, 40-215 days) after surgery. All patients achieved radiographic union. Mean radial height at the time of union was 11.1 mm (SD, ±3.7 mm; range, 6-18 mm), radial inclination was 19.7° (SD, ±5.4°; range, 9° to 30°), ulnar variance was 1.0 mm (SD, ±2.4 mm; range, -3 to 6 mm), and volar tilt was 1.4° (SD, ±5.2°; range, -10° to 14°). Mean articular displacement was 1.7 mm (SD, ±1.7 mm; range, 0-6 mm). Malalignment of at least one of these radiographic parameters was identified in 16 of 24 patients at the time of union. Conclusions Dorsal spanning plate fixation offers an alternative treatment option for comminuted intra-articular distal radius fractures (AO 23-C3). Although this technique presents a straightforward means for fixation of complex distal radius fractures, radiographic outcomes may be inferior relative to less complex fractures treated with standard volar plating techniques. Type of study/level of evidence Therapeutic IV.
Collapse
Affiliation(s)
- Behnam Sharareh
- Department of Orthopedic Surgery, Baylor College of Medicine, Houston, TX
| | - Scott Mitchell
- Department of Orthopedic Surgery, Baylor College of Medicine, Houston, TX
| |
Collapse
|
19
|
Lauder A, Hanel DP. Spanning Bridge Plate Fixation of Distal Radial Fractures. JBJS Rev 2019; 5:01874474-201702000-00002. [PMID: 28248738 DOI: 10.2106/jbjs.rvw.16.00044] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Alexander Lauder
- Department of Orthopaedics, University of Washington, Seattle, Washington
| | | |
Collapse
|
20
|
Huish EG, Coury JG, Ibrahim MA, Trzeciak MA. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction. Hand (N Y) 2018; 13:346-349. [PMID: 28403633 PMCID: PMC5987982 DOI: 10.1177/1558944717704514] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background: The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Methods: Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. Results: All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Conclusions: Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.
Collapse
Affiliation(s)
- Eric G. Huish
- Valley Orthopedic Surgery Residency, Modesto, CA, USA
- Eric G. Huish Jr, Valley Orthopedic Surgery Residency, 1441 Florida Avenue, Modesto, CA 95350, USA.
| | - John G. Coury
- Valley Orthopedic Surgery Residency, Modesto, CA, USA
| | | | | |
Collapse
|
21
|
Tinsley BA, Ilyas AM. Distal Radius Fractures in a Functional Quadruped: Spanning Bridge Plate Fixation of the Wrist. Hand Clin 2018; 34:113-120. [PMID: 29169592 DOI: 10.1016/j.hcl.2017.09.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Patients who require assistive devices with their hands for mobilization are called functional quadrupeds. These patients pose a unique challenge after they have a distal radius fracture, as their injury not only limits the wrist but also compromises ambulation. The authors propose a different treatment strategy for functional quadrupeds to improve mobilization and weight-bearing with the injured limb after a distal radius fracture. In this article, the authors define the functional quadruped and describe their technique of spanning bridge plate fixation with a retrospective review of patient outcomes.
Collapse
Affiliation(s)
- Brian A Tinsley
- Rothman Institute at Thomas Jefferson University, 925 Chestnut Street, Philadelphia, PA 19107, USA
| | - Asif M Ilyas
- Rothman Institute at Thomas Jefferson University, 925 Chestnut Street, Philadelphia, PA 19107, USA.
| |
Collapse
|
22
|
Gay AM, Samson P, Legré R. Fractures articulaires complètes de l’extrémité distale du radius chez le sujet jeune actif. HAND SURGERY & REHABILITATION 2016; 35S:S51-S54. [DOI: 10.1016/j.hansur.2016.09.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Revised: 04/23/2016] [Accepted: 09/15/2016] [Indexed: 11/16/2022]
|
23
|
Lauder A, Agnew S, Bakri K, Allan CH, Hanel DP, Huang JI. Functional Outcomes Following Bridge Plate Fixation for Distal Radius Fractures. J Hand Surg Am 2015; 40:1554-62. [PMID: 26143028 DOI: 10.1016/j.jhsa.2015.05.008] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2015] [Revised: 05/11/2015] [Accepted: 05/11/2015] [Indexed: 02/02/2023]
Abstract
PURPOSE To determine the functional outcomes of patients treated with dorsal spanning distraction bridge plate fixation for distal radius fractures. METHODS All adult patients at our institution who underwent treatment of a unilateral distal radius fracture using a dorsal bridge plate from 2008 to 2012 were identified retrospectively. Patients were enrolled in clinical follow-up to assess function. Wrist range of motion, grip strength, and extension torque were measured systematically and compared with the contralateral, uninjured wrist. Patients also completed Quick-Disabilities of the Arm, Shoulder, and Hand and Patient-Rated Wrist Evaluation outcomes questionnaires. RESULTS Eighteen of 100 eligible patients, with a minimum of 1 year from the time of implant removal, were available for follow-up (mean, 2.7 y). All fracture patterns were comminuted and intra-articular (AO 23.C3). There were significant decreases in wrist flexion (43° vs 58°), extension (46° vs 56°), and ulnar deviation (23° vs 29°) compared with the contralateral uninjured wrist. Grip strength was 86% and extension torque was 78% of the contralateral wrist. Comparison of dominant and nondominant wrist injuries identified nearly complete recovery of grip (95%) and extension (96%) strength of dominant-sided wrist injuries, compared with grip (79%) and extension (65%) strength in those with an injured nondominant wrist. Mean Quick-Disabilities of the Arm, Shoulder, and Hand and Patient-Rated Wrist Evaluation scores were 16 and 14, respectively. There were 2 cases of postoperative surgical site pain and no cases of infection, tendonitis, or tendon rupture. CONCLUSIONS Distraction bridge plate fixation for distal radius fractures is safe with minimal complications. Functional outcomes are similar to those published for other treatment methods. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic IV.
Collapse
Affiliation(s)
- Alexander Lauder
- Department of Orthopaedics, University of Washington, Seattle, WA.
| | - Sonya Agnew
- Division of Plastic Surgery, Northwestern University, Jesse Brown VAMC, Chicago, IL
| | - Karim Bakri
- Division of Plastic Surgery, Mayo Clinic, Rochester, MN
| | | | - Douglas P Hanel
- Department of Orthopaedics, University of Washington, Seattle, WA
| | - Jerry I Huang
- Department of Orthopaedics, University of Washington, Seattle, WA
| |
Collapse
|