Eckardt Forceps Tip Widening for the Removal of Posterior Intraocular Foreign Bodies Bigger Than 1 mm.
Retina 2023;
43:148-151. [PMID:
31985555 DOI:
10.1097/iae.0000000000002757]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
PURPOSE
To propose a new technique with an "old" tool to allow for better intraocular foreign body (IOFB) grasping and manipulation during mininvasive vitreoretinal surgery.
METHODS
The authors report herein their technique on seven eyes, diagnosed with posterior IOFBs, in which the surgery consisted of a 23-gauge vitrectomy, using, for IOFB grasping, a Grieshaber DSP 23-gauge Eckardt forceps, properly modified intraoperatively. Such result was achieved by enlarging the forceps opening bite, according to the IOFB size.
RESULTS
In all patients, IOFBs were removed using the modified 23-gauge Grieshaber Eckardt forceps. In 6 cases, a combined phacovitrectomy was performed, and the IOFB expressed through the corneal phacoincision; in one phakic patient, the removal was performed through the sclerotomy, extended just as needed.
CONCLUSION
The Grieshaber Eckardt forceps commonly used in MIVS can be used in IOFB surgery for a scleral or corneal removal. In case of IOFB bigger than 1 mm, enlarging the forceps bite according the IOFB size provides a firm and safe grip, allowing the surgeon to complete the surgery without switching to bigger and more traumatic instrumentation, reducing collateral damage and shortening the surgery time.
Collapse