Edgar AK, Connor HRM, Kamarelddin S, Musich J, Mclouta S, Choi E, Thamer A, Salcedo A, Nazarian A, Chong LX. Anterior segment optical coherence tomography meibography compared with keratograph meibography. Ophthalmic Physiol Opt 2024; 44:115-123. [PMID: 37697893 DOI: 10.1111/opo.13231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 08/28/2023] [Accepted: 08/30/2023] [Indexed: 09/13/2023]
Abstract
PURPOSE The aim of this study was to determine the feasibility of using readily accessible technology, anterior segment optical coherence tomography (AS-OCT), to detect and grade meibomian gland dropout and examine its interchangeability with the Oculus Keratograph 5M (K5M). METHODS A total of 30 participants (30 eyes) with a median age of 21 (range = 19-28 years) were recruited. Meibography was performed using two commercially available imaging devices to look at the structure of the meibomian glands and grade them subjectively in real time, and image analysis was used to quantify meibomian gland loss objectively. Gland loss as imaged by the two techniques was graded using the meiboscore grading schema. Test-retest reliability was determined with intraclass correlation coefficients (ICCs). Weighted kappa was used to evaluate agreement between the two imaging devices and four methods of image analysis. Spearman and Pearson correlation coefficients were used to determine the association of structural measurements between each of the techniques. The agreement between the two imaging techniques was determined with the Bland-Altman analysis. RESULTS Reliability of subjective grading was strong for AS-OCT (ICC: 0.92, 95% CI: 0.83-0.96, p < 0.001) and K5M (ICC: 0.96, 95% CI: 0.96-0.91, p = 0.001). Image analysis with ImageJ reliability was strong between the imaging devices (ICC: 0.84, 95% CI: 0.55-0.94, p < 0.001). Agreement between each subjective technique was fair, κ = 0.45 (95% CI: 0.17-0.73, p < 0.001) and a positive Spearman correlation was also observed (r = 0.52, p < 0.001). There was no significant difference between the mean meibomian gland loss measured with ImageJ between AS-OCT and K5M (0.92 ± 6.28, p = 0.26). The 95% limits of agreement were -12.45% to +14.04%. CONCLUSION These findings suggest subjective real-time grading of meibomian gland loss could be performed using readily available AS-OCT technology and that this method was interchangeable with the K5M.
Collapse
Affiliation(s)
- Amanda K Edgar
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
- Digital Learning, Deakin Learning Futures, Deakin University, Geelong, Victoria, Australia
| | - Heather R M Connor
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| | - Shayma Kamarelddin
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| | - Jack Musich
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| | - Stefanos Mclouta
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| | - Evelyn Choi
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| | - Afnan Thamer
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| | - Adrian Salcedo
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| | - Aram Nazarian
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| | - Luke X Chong
- School of Medicine (Optometry), Faculty of Health, Deakin University, Waurn Ponds, Victoria, Australia
| |
Collapse
|
2
|
Therapeutic Potential of d-MAPPS™ for Ocular Inflammatory Diseases and Regeneration of Injured Corneal and Retinal Tissue. Int J Mol Sci 2022; 23:ijms232113528. [DOI: 10.3390/ijms232113528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 11/01/2022] [Accepted: 11/03/2022] [Indexed: 11/06/2022] Open
Abstract
The invasion of microbial pathogens and/or sterile inflammation caused by physical/chemical injuries, increased ocular pressure, oxidative stress, and ischemia could lead to the generation of detrimental immune responses in the eyes, which result in excessive tissue injury and vision loss. The bioavailability of eye drops that are enriched with immunoregulatory and trophic factors which may concurrently suppress intraocular inflammation and promote tissue repair and regeneration is generally low. We recently developed “derived- Multiple Allogeneic Proteins Paracrine Signaling regenerative biologics platform technology d-MAPPS™”, a bioengineered biological product which is enriched with immunomodulatory and trophic factors that can efficiently suppress detrimental immune responses in the eye and promote the repair and regeneration of injured corneal and retinal tissues. The results obtained in preclinical and clinical studies showed that d-MAPPS™ increased the viability of injured corneal cells, inhibited the production of inflammatory cytokines in immune cells, alleviated inflammation, and restored vision loss in patients suffering from meibomian gland dysfunction and dry eye disease. Herewith, we emphasized molecular mechanisms responsible for the therapeutic efficacy of d-MAPPS™ and we presented the main beneficial effects of d-MAPPS™ in clinical settings, indicating that the topical administration of d-MAPPS™ could be considered a new therapeutic approach for the treatment of ocular inflammatory diseases and for the repair and regeneration of injured corneal and retinal tissues.
Collapse
|
3
|
Liu S, Li S, Li M, Zeng S, Chen B, Zhang L. Evaluation of the Ocular Surface and Meibomian Gland in Obstructive Sleep Apnea Hypopnea Syndrome. Front Med (Lausanne) 2022; 9:832954. [PMID: 35223929 PMCID: PMC8863666 DOI: 10.3389/fmed.2022.832954] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 01/14/2022] [Indexed: 12/03/2022] Open
Abstract
Purpose To assess the ocular surface and meibomian gland (MG) of patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and to explore the effects of surgery for OSAHS on the ocular surface and MG. Methods Based on the apnea hypopnea index (AHI), 21 patients with mild OSAHS (Group A, 5/h ≤ AHI < 15/h), 20 patients with moderate OSAHS (Group B, 15/h ≤ AHI < 30/h), 62 patients with severe OSAHS (Group C, AHI ≥ 30/h) were examined. The ocular surface and MG were evaluated using Keratograph 5M. In addition, detailed Ophthalmic examination including visual acuity, refraction, slit-lamp examination of the anterior segment, corneal fluorescein staining (CFS), ocular surface disease index (OSDI) scoring, Schirmer I test (SIT) and serum lipid measurement was performed. For OSAHS patients with dry eye syndrome (DES) who underwent uvulopalatopharyngoplasty for improving AHI, the conditions of the ocular surface and MG were compared before surgery and 3 months after surgery. Only the data of the right eyes were analyzed. Results There were no significantly different in the OSDI score, tear meniscus height (TMH), or loss ratio of the lower eyelid (LRLE) among these groups. The first non-invasive tear film breakup time (fNIBUT), average non-invasive tear film breakup time (avNIBUT), bulbar redness index (BRI), lipid layer grading (LLG), CFS, plugged orifices and distortion in MG, the loss ratio of upper eyelid (LRUE), and the incidence of DES, floppy eyelid syndrome (FES) and meibomian gland dysfunction (MGD) showed significant differences between Groups A and C (p = 0.015, p = 0.018, p < 0.001, p = 0.022, p = 0.036, p = 0.007, p = 0.019, p = 0.017, p = 0.045, p = 0.013, and p = 0.029, respectively). The SIT in the Group A was significantly higher than in Group B (p = 0.025) and in Group C (p < 0.001). In the correlation analyses, the fNIBUT, avNIBUT, SIT and LLG had negative correlations with the AHI (p = 0.013, p = 0.010, p = 0.003, p < 0.001, and p = 0.006, respectively). The BRI, CFS and LRUE were positively correlated with the AHI (p = 0.006, p = 0.007, and p = 0.046, respectively). Three months after surgery, there were no significant differences in the ocular surface or MG. Conclusion Patients with severe OSAHS have poor stability of tear film and are prone to lipid-deficient dry eye as a result of the loss of meibomian gland. By improving the AHI, the ocular surface damage of OSAHS patients cannot be reversed in a short time.
Collapse
Affiliation(s)
- Shaohua Liu
- Department of Ophthalmology, The Second Xiangya Hospital of Central South University, Changsha, China.,Hunan Clinical Research Centre of Ophthalmic Disease, Changsha, China
| | - Shisheng Li
- Department of Otorhinolaryngology, The Second Xiangya Hospital of Central South University, Changsha, China
| | - Mengmeng Li
- Department of Otorhinolaryngology, The Second Xiangya Hospital of Central South University, Changsha, China
| | - Shiying Zeng
- Department of Otorhinolaryngology, The Second Xiangya Hospital of Central South University, Changsha, China
| | - Baihua Chen
- Department of Ophthalmology, The Second Xiangya Hospital of Central South University, Changsha, China.,Hunan Clinical Research Centre of Ophthalmic Disease, Changsha, China
| | - Liwei Zhang
- Department of Ophthalmology, The Second Xiangya Hospital of Central South University, Changsha, China.,Hunan Clinical Research Centre of Ophthalmic Disease, Changsha, China
| |
Collapse
|
4
|
Comparison of Two Thermal Pulsation Systems in the Treatment of Meibomian Gland Dysfunction. Optom Vis Sci 2022; 99:323-332. [DOI: 10.1097/opx.0000000000001892] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
5
|
Song Y, Yu S, He X, Yang L, Wu Y, Qin G, Zhang Q, Deep Singh Talwar G, Xu L, Moore JE, He W, Pazo EE. Tear film interferometry assessment after intense pulsed light in dry eye disease: A randomized, single masked, sham-controlled study. Cont Lens Anterior Eye 2021; 45:101499. [PMID: 34433517 DOI: 10.1016/j.clae.2021.101499] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 08/05/2021] [Accepted: 08/05/2021] [Indexed: 01/11/2023]
Abstract
BACKGROUND Inadequate meibomian glands (MGs) secretion can lead to dry eye signs and symptoms. Tear film lipid layer (TFLL) secreted by MGs protects and prevents rapid evaporation of tear film. The purpose was to assess TFLL alteration and function in patients with evaporative dry eye (EDE) using tear interferometry after optimal pulse light technology (OPT) intense pulsed light (IPL). METHODS This prospective randomized examiner-masked sham- controlled study included 86 participants (142 eyes) with DED. IPL or sham procedure was performed on day 0, 21, and 42. Ocular Surface Disease Index (OSDI), non-invasive breakup time (NITBUT), interferometric fringe pattern determined TFLL quality, fluorescein staining (FS), and meibum gland (MG) were assessed at day 0, 21, 42 and 3-month. RESULTS At 3-month, TFLL, NITBUT, MG drop-out, MG quality, MG expressibility, FS and OSDI improved significantly (P < 0.05) in the IPL group, while the sham group had no significant improvements. Except for Meibo-score and FS, all parameters significantly correlated with the improvement in TFLL following IPL treatment. Additionally, artificial tears usage was significantly less in the IPL group from D-42 onwards. CONCLUSION IPL treatment demonstrated the ability to improve TFLL quality and clinically reduced sign and symptoms of DED thereby reducing the frequency of artificial tears use.
Collapse
Affiliation(s)
- Yilin Song
- He Eye Specialist Hospital, No.128 North Huanghe Street, Shenyang, China; The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Sile Yu
- He University, Shenyang, China
| | | | - Lanting Yang
- He Eye Specialist Hospital, No.128 North Huanghe Street, Shenyang, China; The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yi Wu
- He Eye Specialist Hospital, No.128 North Huanghe Street, Shenyang, China; The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Guanghao Qin
- He Eye Specialist Hospital, No.128 North Huanghe Street, Shenyang, China; The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Qing Zhang
- He Eye Specialist Hospital, No.128 North Huanghe Street, Shenyang, China; The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | | | - Ling Xu
- He Eye Specialist Hospital, No.128 North Huanghe Street, Shenyang, China
| | - Jonathan E Moore
- Cathedral Eye Clinic, 89-91 Academy Street, Belfast, United Kingdom; Biomedical Sciences Research Institute, University of Ulster, Coleraine, United Kingdom
| | - Wei He
- He Eye Specialist Hospital, No.128 North Huanghe Street, Shenyang, China; He University, Shenyang, China
| | - Emmanuel Eric Pazo
- He Eye Specialist Hospital, No.128 North Huanghe Street, Shenyang, China; He University, Shenyang, China
| |
Collapse
|
6
|
Fan F, Li X, Li K, Jia Z. To Find Out the Relationship Between Levels of Glycosylated Hemoglobin with Meibomian Gland Dysfunction in Patients with Type 2 Diabetes. Ther Clin Risk Manag 2021; 17:797-807. [PMID: 34393486 PMCID: PMC8355550 DOI: 10.2147/tcrm.s324423] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 07/21/2021] [Indexed: 12/14/2022] Open
Abstract
Aim The aim of this study was to investigate the relationship between levels of glycosylated hemoglobin (HbA1c) with meibomian gland dysfunction (MGD) in patients with type 2 diabetes mellitus (T2DM) and to further explore the related influencing factors. Methods Totally, 167 patients with T2DM and 68 non-diabetic subjects were selected. Further, T2DM patients were divided into 2 groups based on 7% HbA1c. Standard patient evaluation of eye dryness (SPEED), lipid layer thickness (LLT), partial blink (PB) ratio, percentage of partial glands (MGP), meibomian gland yielding liquid secretion (MGYLS), meibomian gland yielding secretion score (MGYSS), line of marx (LOM), tear break up time (TBUT), tear meniscus height (TMH) and Schirmer I test (SIT) were applied to evaluate meibomian gland function. Finally, the correlation between HbA1c and various indicators was also analyzed. Results Between HbA1c≥7% group and HbA1c<7% group, the differences in LLT (P=0.003), MGP (P<0.001), MGYLS (P=0.014) and TBUT (P=0.015) were all statistically significant. Compared with the non-diabetic group, LLT (P=0.020), MBP (P<0.001), MGYS (P< 0.001), TBUT (P<0.001), SIT (P=0.001), TMH (P=0.017) and LOM (P<0.001) were significantly different in HbA1c≥7% group, while the differences of MBP (P=0.031), MGYSS (P<0.001), SIT (P=0.001) and LOM (P<0.001) in HbA1c≤7% group were statistically significant. Besides, the prevalence of MGD in HbA1c≥7% group was evidently higher than that in non-diabetic group (P=0.002). Correlation analysis showed that HbA1c was significantly associated with the LTT and MGP. Conclusion HbA1c≥7% is likely to result in meibomian gland function dysfunctions in T2DM patients, especially related to LLT and MGP.
Collapse
Affiliation(s)
- Fang Fan
- Department of Ophthalmology, Hebei General Hospital, Shijiazhuang, 050051, People's Republic of China
| | - Xiaodan Li
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shijiazhuang, 050000, People's Republic of China
| | - Kejun Li
- Department of Ophthalmology, Hebei General Hospital, Shijiazhuang, 050051, People's Republic of China
| | - Zhiyang Jia
- Department of Ophthalmology, Hebei General Hospital, Shijiazhuang, 050051, People's Republic of China
| |
Collapse
|
7
|
Ward CD, Murchison CE, Petroll WM, Robertson DM. Evaluation of the Repeatability of the LacryDiag Ocular Surface Analyzer for Assessment of the Meibomian Glands and Tear Film. Transl Vis Sci Technol 2021; 10:1. [PMID: 34338722 PMCID: PMC8340660 DOI: 10.1167/tvst.10.9.1] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose This study aimed to determine the intra- and interobserver repeatability of the new LacryDiag Ocular Surface Analyzer and compare it to a similar all-in-one device, the OCULUS Keratograph 5M. Methods Thirty healthy subjects aged 18 years and above were recruited for this study. All patients were free of any existing ocular pathology. The LacryDiag Ocular Surface Analyzer was used to evaluate tear meniscus height, interferometry, noninvasive tear break-up time (NIBUT), and meibography. The same or analogous exams were performed using the OCULUS Keratograph 5M. Test equivalation was used to compare data from corresponding examinations. Paired t-tests and coefficient of variation were used to determine inter- and intraobserver repeatability. Bland-Altman analysis was used to determine level of agreement between devices. Results There were no differences in mean values for tear meniscus height, NIBUT, or tear film interferometry between observers for either device. Significant differences were found between observers for meibography when using the LacryDiag (P = 0.008 for percent loss calculation and P = 0.004 for grading scale). Intra-observer variability for NIBUT was significantly higher for the Keratograph (P = 0.0003 for observer A and P < 0.0001 for observer B). Conclusions There was a good correlation but poor agreement between devices for a given observer. This was likely influenced by the use of repeated testing and the non-dry eye cohort. Translational Relevance Both the repeatability of the testing device and the use of multiple outcome measures are essential for the diagnosis and monitoring of patients with dry eye disease (DED).
Collapse
Affiliation(s)
- Cameron D Ward
- Department of Ophthalmology, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Caroline E Murchison
- Department of Ophthalmology, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - W Matthew Petroll
- Department of Ophthalmology, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Danielle M Robertson
- Department of Ophthalmology, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
8
|
Muhafiz E, Bozkurt E, Erten R. Impression cytology and meibomian glands in conjunctivochalasis. Eur J Ophthalmol 2021; 32:11206721211008789. [PMID: 33843265 DOI: 10.1177/11206721211008789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the tear parameters, meibomian glands and lid margin and tarsal conjunctival impression cytology in patients with conjunctivochalasis (CCH). METHODS The study included 57 patients diagnosed with CCH and 35 healthy volunteers. Tear break-up time (TBUT) was measured and Schirmer test was performed. Meibomian gland morphologies, dropout rates, and meiboscores were evaluated using meibography. Finally, impression cytology samples were taken by pressing the impression filters on the lower lid margin and lower tarsal conjunctiva. The samples were evaluated according to the Nelson grading system. RESULTS Schirmer test was longer and TBUT was shorter in the study group (p = 0.035 and p < 0.001, respectively). The median of meibomian gland dropout rate was 33.45% (Interquartile range [IQR]; 23.17%-49.75%) and 18.80% (IQR; 12.35%-26.50%) in the study and control groups, respectively (p < 0.001). There was no significant difference in terms of lid-margin cytology between the two groups (p = 0.481). In tarsal conjunctiva cytology, the median value of Nelson grade of the study group was 2 (IQR; 1-2) and that of the control group was 1 (IQR; 1-2) (p = 0.040). When Nelson grade-2 and above was accepted as the pathological limit, it was found that 27.5% of the study group and 15.2% of the control group showed pathological findings (p = 0.204). CONCLUSIONS In patients with CCH, damage occurs in the tarsal conjunctiva with the effects of redundant conjunctival folds. In these patients, atrophy occurs in the meibomian glands and tear stability is impaired. Therefore, CCH should not be overlooked in clinical practice.
Collapse
Affiliation(s)
- Ersin Muhafiz
- Department of Ophthalmology, Faculty of Medicine, Kafkas University, Kars, Turkey
| | - Erdinç Bozkurt
- Department of Ophthalmology, Faculty of Medicine, Kafkas University, Kars, Turkey
| | - Remzi Erten
- Department of Pathology, Faculty of Medicine, Van Yüzüncüyıl University, Van, Turkey
| |
Collapse
|
9
|
Abstract
PURPOSE To evaluate the effect of obstructive sleep apnea-hypopnea syndrome (OSAHS) on the meibomian glands, ocular surface, and tear parameters. METHODS The study included 59 individuals (32 subjects with OSAHS, 27 control subjects) who underwent polysomnography in the Chest Diseases Clinic. The right eyes of all individuals were evaluated in the Ophthalmology Clinic. The first noninvasive tear break-up time (f-NTBUT) and the average noninvasive tear break-up time were measured, and Schirmer test was applied. Meibography was taken (Sirius; CSO, Florence, Italy), and meiboscore was used for indexing meibography. Finally, a sample was taken for conjunctival impression cytology. RESULTS In the study and control groups, the median of f-NTBUT was 2.1 seconds [interquartile range (IQR); 1.5-5.0] and 5.7 seconds (IQR; 2.9-8.8) and the median of average noninvasive tear break-up time was 5.6 seconds (IQR; 3.6-9.5) and 7.2 seconds (IQR; 4.2-10.7), respectively (P = 0.007 and P = 0.487, respectively). The mean Schirmer value was 16.3 ± 5.9 mm (range; 5-25) and 17.3 ± 6.6 mm (range; 5-30) in the study and control groups (P = 0.604). In upper eyelid meibography, the median of loss in the meibomian glands was 20.10% (IQR; 11.60%-40.80%) in the study group and 14.70% (IQR; 10.40%-21.30%) in the control group (P = 0.043). In lower eyelid meibography, the median of loss in the meibomian glands was 19.00% (IQR; 13.60%-35.30%) in the study group and 12.40% (IQR; 9.10%-16.40%) in the control group (P = 0.002). The median of the Nelson grade in conjunctival impression cytology was 1 (IQR; 0-1) in the study group and 1 (IQR; 0-1) in the control group (P = 0.445). CONCLUSIONS The loss in the meibomian glands together with the shortened f-NTBUT shows that there could be a predisposition in OSAHS for evaporative dry eye originating from meibomian gland damage.
Collapse
|
10
|
Increased Expression of TLR4 in Circulating CD4+T Cells in Patients with Allergic Conjunctivitis and In Vitro Attenuation of Th2 Inflammatory Response by Alpha-MSH. Int J Mol Sci 2020; 21:ijms21217861. [PMID: 33114004 PMCID: PMC7672642 DOI: 10.3390/ijms21217861] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 10/17/2020] [Accepted: 10/21/2020] [Indexed: 12/24/2022] Open
Abstract
Ocular allergic diseases are frequently seen in ophthalmological clinical practice. Immunological damage is mediated by a local Th2 inflammatory microenvironment, accompanied by changes in circulating cell subsets, with more effector cells and fewer T regulatory cells (Tregs). This study aimed to evaluate the involvement of toll-like receptor 4 (TLR4) and α-melanocyte stimulating hormone (α-MSH) in the immune regulation associated with perennial allergic conjunctivitis (PAC). We performed an Ag-specific stimulation during 72 h of culturing with or without lipopolysaccharide (LPS) or α-MSH in peripheral blood mononuclear cells (PBMC), analyzing the cell subsets and cytokines induced by the stimuli. We also determined α-MSH in tear samples from healthy donors (HD) or PAC patients. Our findings demonstrate an immunological dysregulation characterized by an increased frequency of CD4+TLR4+ in the PBMC of patients with PAC, compared to HD. Most of these CD4+TLR4+ cells were also CD25+, and when α-MSH was added to the culture, the percentage of CD4+CD25+FoxP3+ increased significantly, while the percentage of CD69+ cells and cytokines IL-4 and IL-6 were significantly decreased. In tears, we found an increased concentration of α-MSH in PAC patients, compared with HD. These findings indicate a novel mechanism involved in controlling ocular allergic diseases, in which α-MSH diminishes the concentration of IL-6 and IL-4, restoring the frequency of Tregs and down-regulating CD4 activation. Moreover, we demonstrated the involvement of CD4+TLR4+ cells as an effector cell subset in ocular allergy.
Collapse
|
11
|
Schmidl D, Schlatter A, Chua J, Tan B, Garhöfer G, Schmetterer L. Novel Approaches for Imaging-Based Diagnosis of Ocular Surface Disease. Diagnostics (Basel) 2020; 10:diagnostics10080589. [PMID: 32823769 PMCID: PMC7460546 DOI: 10.3390/diagnostics10080589] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 07/28/2020] [Accepted: 08/10/2020] [Indexed: 02/07/2023] Open
Abstract
Imaging has become indispensable in the diagnosis and management of diseases in the posterior part of the eye. In recent years, imaging techniques for the anterior segment are also gaining importance and are nowadays routinely used in clinical practice. Ocular surface disease is often synonymous with dry eye disease, but also refers to other conditions of the ocular surface, such as Meibomian gland dysfunction or keratitis and conjunctivitis with different underlying causes, i.e., allergies or infections. Therefore, correct differential diagnosis and treatment of ocular surface diseases is crucial, for which imaging can be a helpful tool. A variety of imaging techniques have been introduced to study the ocular surface, such as anterior segment optical coherence tomography, in vivo confocal microscopy, or non-contact meibography. The present review provides an overview on how these techniques can be used in the diagnosis and management of ocular surface disease and compares them to clinical standard methods such as slit lamp examination or staining of the cornea or conjunctiva. Although being more cost-intensive in the short term, in the long term, the use of ocular imaging can lead to more individualized diagnoses and treatment decisions, which in turn are beneficial for affected patients as well as for the healthcare system. In addition, imaging is more objective and provides good documentation, leading to an improvement in patient follow-up and education.
Collapse
Affiliation(s)
- Doreen Schmidl
- Department of Clinical Pharmacology, Medical University of Vienna, 1090 Vienna, Austria; (D.S.); (A.S.); (G.G.)
| | - Andreas Schlatter
- Department of Clinical Pharmacology, Medical University of Vienna, 1090 Vienna, Austria; (D.S.); (A.S.); (G.G.)
- Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery-Karl Landsteiner Institute, Hanusch Hospital, 1140 Vienna, Austria
| | - Jacqueline Chua
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 169856, Singapore; (J.C.); (B.T.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE), Nanyang Technological University, Singapore 639798, Singapore
| | - Bingyao Tan
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 169856, Singapore; (J.C.); (B.T.)
- SERI-NTU Advanced Ocular Engineering (STANCE), Nanyang Technological University, Singapore 639798, Singapore
| | - Gerhard Garhöfer
- Department of Clinical Pharmacology, Medical University of Vienna, 1090 Vienna, Austria; (D.S.); (A.S.); (G.G.)
| | - Leopold Schmetterer
- Department of Clinical Pharmacology, Medical University of Vienna, 1090 Vienna, Austria; (D.S.); (A.S.); (G.G.)
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore 169856, Singapore; (J.C.); (B.T.)
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore 169857, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE), Nanyang Technological University, Singapore 639798, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232, Singapore
- Institute of Molecular and Clinical Ophthalmology, CH-4031 Basel, Switzerland
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
- Correspondence: ; Tel.: +43-1-40400-29810; Fax: +43-1-40400-29990
| |
Collapse
|
12
|
Luensmann D, Omali NB, Suko A, Drolle E, Heynen M, Subbaraman LN, Scales C, Fadli Z, Jones L. Kinetic Deposition of Polar and Non-polar Lipids on Silicone Hydrogel Contact Lenses. Curr Eye Res 2020; 45:1477-1483. [PMID: 32281422 DOI: 10.1080/02713683.2020.1755696] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Purpose: This study investigated kinetic lipid uptake to four silicone hydrogel (SiHy) lenses over a period of four weeks, using an in-vitro radiolabel method. Methods: Four contemporary monthly replacement SiHy lenses (lotrafilcon B, senofilcon C, comfilcon A, samfilcon A) were incubated in three different solutions: 1) An artificial tear solution (ATS) containing 14C-labeled phosphatidylcholine (PC), 2) an ATS containing 14C-cholesteryl oleate (CO) and 3) an ATS containing four 14C-radiolabeled lipids (PC, phosphatidylethanolamine, CO, and cholesterol (total lipid)). After 16 hours, lipids were extracted twice from the lenses with chloroform:methanol and the radioactive counts determined the lipid quantities to simulate 1 day of wear. OPTI-FREE PureMoist (Alcon) was used to clean and disinfect the remaining lenses daily and the lipid quantities were further determined after 2 weeks and 4 weeks. Results: The amount of total lipid increased for all lenses over time (p < .01). After four weeks, total lipid accumulated was 20.26 ± 0.15 µg/lens for senofilcon C, which was significantly higher (p < .01) than all other lens materials (samfilcon A - 17.84 ± 0.21; comfilcon A - 16.65 ± 0.12; lotrafilcon B - 7.41 ± 0.56 µg/lens). CO was highest on lotrafilcon B (1.26 ± 0.13 µg/lens) and senofilcon C attracted the most PC (3.95 ± 0.12 µg/lens) compared to the other materials. Conclusion: The amount of both polar and non-polar lipid deposition on monthly replacement SiHy lenses increased over 4 weeks, with significant differences being seen between lens materials.
Collapse
Affiliation(s)
- Doerte Luensmann
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo , Waterloo, Canada
| | - Negar Babaei Omali
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo , Waterloo, Canada
| | - Adeline Suko
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo , Waterloo, Canada
| | - Elizabeth Drolle
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo , Waterloo, Canada
| | - Miriam Heynen
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo , Waterloo, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo , Waterloo, Canada
| | | | - Zohra Fadli
- Johnson & Johnson Vision Care, Inc , Jacksonville, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo , Waterloo, Canada
| |
Collapse
|
13
|
Lee SM, Chung SJ, Lew H. Evaluation of Tear Film Lipid Layer Thickness Measurements Obtained Using an Ocular Surface Interferometer in Nasolacrimal Duct Obstruction Patients. KOREAN JOURNAL OF OPHTHALMOLOGY 2018; 32:445-450. [PMID: 30549467 PMCID: PMC6288021 DOI: 10.3341/kjo.2018.0012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Accepted: 03/16/2018] [Indexed: 11/28/2022] Open
Abstract
Purpose To compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients. Methods We reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography. Results Tear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were 62.4 ± 24.0, 86.7 ± 17.9, and 71.7 ± 23.3 nm, respectively. Significant changes in the minimum, maximum, and average LLT (74.8 ± 23.6, 98.8 ± 11.0, and 91.6 ± 16.1 nm, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation. Conclusions Overall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.
Collapse
Affiliation(s)
- Sang Min Lee
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, Korea
| | - Sok Joong Chung
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, Korea
| | - Helen Lew
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, Korea.
| |
Collapse
|
14
|
Safonova TN, At'kova EL, Kintyukhina NP, Reznikova LV. [Modern methods of evaluating the morphological and functional state of the eyelids in chronic blepharitis]. Vestn Oftalmol 2018; 134:276-281. [PMID: 30499529 DOI: 10.17116/oftalma2018134051276] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The article reviews the literature on methods of evaluating the morphological and functional state of the eyelids in chronic blepharitis. Development of methods continues together with further research on the etiology and pathogenesis of the disease.
Collapse
Affiliation(s)
- T N Safonova
- Research Institute of Eye Diseases, 11A Rossolimo St., Moscow, Russian Federation, 119021
| | - E L At'kova
- Research Institute of Eye Diseases, 11A Rossolimo St., Moscow, Russian Federation, 119021
| | - N P Kintyukhina
- Research Institute of Eye Diseases, 11A Rossolimo St., Moscow, Russian Federation, 119021
| | - L V Reznikova
- I.M. Sechenov First Moscow State Medical University, Chair of Ophthalmology, 8-2 Malaya Trubetskaya St., Moscow, Russian Federation, 119991
| |
Collapse
|
15
|
Meibomian Glands and Ocular Surface Changes After Closure of Meibomian Gland Orifices in Rabbits. Cornea 2018; 37:218-226. [PMID: 29189289 DOI: 10.1097/ico.0000000000001460] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To investigate changes in the corneal surface, tear film, and meibomian glands after meibomian gland orifice closure. METHODS Seventy-two eyes of 36 rabbits were used. In the study group (n = 36), the meibomian gland orifices of both upper and lower eyelids in the right eyes were electrosurgically coagulated. The 36 untreated left eyes were used as controls. Corneal wetting properties were measured 1, 3, 7, and 14 days after coagulation. The eyelid sections were stained with anti-cytokeratin (CK)1, CK5, and CK6 antibody 8 weeks after coagulation. The area of the secretory acini around one meibomian gland duct was measured, and meibography of rabbits was performed 8 weeks after meibomian gland orifice closure. RESULTS Three days after coagulation, the corneal wetting property was decreased compared with controls. The meibomian gland ducts gradually dilated in the study group over time. The epithelium of the central ducts in both groups was stained with CK5 and CK6, but not CK1. Although the mean area of the secretory acini in the study group (0.10 ± 0.04 mm) was significantly smaller than that of the control group (0.18 ± 0.04; P = 0.004), meibography showed normal morphology in both study and control groups. CONCLUSIONS Meibomian gland orifice closure reduced corneal wetting property and induced meibomian gland duct dilation accompanied by shrinkage of secretory acini. Meibography could not detect early changes in the meibomian gland after closure of the orifice. Therefore, when the orifice is obstructed, more active treatments are needed before structural changes occur.
Collapse
|