1
|
Chen L, Khamar P, Wang Y, Fu H, Shetty R. Evaluation of Higher-Order Aberrations After the Smooth Incision Lenticular Keratomileusis (SILK TM) Procedure Using the ELITA TM Femtosecond Platform for Correction of Myopic and Astigmatic Refractive Errors. Clin Ophthalmol 2024; 18:2155-2166. [PMID: 39070107 PMCID: PMC11283805 DOI: 10.2147/opth.s466932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Accepted: 07/10/2024] [Indexed: 07/30/2024] Open
Abstract
Purpose To evaluate the changes of higher-order wavefront aberrations following the Smooth Incision Lenticular Keratomileusis (SILKTM) procedure for correction of myopic refractive errors with and without astigmatism, using the ELITATM Femtosecond Platform. Methods This prospective study included 24 eyes that underwent SILK procedure using one ELITA femtosecond laser system for the correction of myopic refractive errors with and without astigmatism. Preoperative and postoperative 1-day, 1-week, 1-month, 3-month, and 9-month eye exams were measured with a commercial wavefront aberrometer (iDESIGN ® Refractive Studio, Johnson & Johnson Surgical Vision, Inc). Wavefront aberrations up to the 6th order Zernike coefficients, including coma Z(3, -1) and Z(3, 1), spherical aberration Z(4, 1), and the wavefront error of all higher-order aberrations (HOAs RMS), were evaluated across a 6 mm pupil. Results The mean manifest refractive spherical equivalent changed from the preoperative refractions -3.82 ± 1.26 D (range -6.00 to -2.25 D) to the postoperative refractions -0.20 ± 0.15 D (range -0.50 to 0.00 D) at the 9-month follow-up. Compared to baseline preoperative HOAs, the mean postoperative HOAs were significantly increased at the 1-day follow-up. On average, at the 9-month postoperative assessment the vertical coma Z(3, -1) was -0.054 ±0.186 µm, horizontal coma Z(3, 1) was 0.016 ± 0.124 µm, spherical aberration Z(4, 0) was 0.046 ± 0.163 µm, and HOAs RMS was 0.363 ± 0.115 µm across a 6 mm pupil. There is no significant difference in the mean HOAs starting at 1-week follow-up for the horizontal coma (P = 0.346) and spherical aberration (P = 0.095). Conclusions The visual outcomes demonstrated that the SILK procedure for refractive lenticule extraction using ELITA femtosecond laser system is effective and predictable for the correction of myopic refractive errors with and without astigmatism. The ELITA femtosecond laser system induced minimal HOAs in surgical eyes following the SILK procedures. These results demonstrate fast corneal recovery starting at 1-week follow-up, and spherical aberration was not induced.
Collapse
Affiliation(s)
- Li Chen
- Johnson & Johnson Surgical Vision, Inc., Milpitas, CA, USA
| | - Pooja Khamar
- Narayana Nethralaya Eye Hospital, Bangalore, India
| | - Ying Wang
- Johnson & Johnson Surgical Vision, Inc., Irvine, CA, USA
| | - Hong Fu
- Johnson & Johnson Surgical Vision, Inc., Milpitas, CA, USA
| | - Rohit Shetty
- Narayana Nethralaya Eye Hospital, Bangalore, India
| |
Collapse
|
2
|
Feng Y, He R, Qu M, Ma Q, Tian H. Sub-Bowman keratomileusis versus femtosecond laser in situ keratomileusis on the long-term visual recovery: A comparative study. Indian J Ophthalmol 2023; 71:1899-1903. [PMID: 37203052 PMCID: PMC10391504 DOI: 10.4103/ijo.ijo_1543_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/20/2023] Open
Abstract
Purpose To explore the long-term visual quality of the same subjects after sub-Bowman keratomileusis (SBK) or femtosecond laser in situ keratomileusis (FS-LASIK). Methods This prospective study included patients screened for corneal refractive surgery at the Refractive Surgery Center of our Hospital between November 2017 and March 2018. One eye underwent SBK, while the other eye underwent FS-LASIK. Total higher-order aberrations, coma aberrations, and clover aberrations were evaluated before and at 1 month and 3 years after the procedure. The visual satisfaction of both eyes was investigated, respectively. The participants completed a surgical satisfaction questionnaire. Results Thirty-three patients were included. There were no significant differences in total higher-order aberrations, coma aberrations, and clover aberrations between the two procedures before and 1 month and 3 years after surgery (all P > 0.05), except for the total coma aberrations in FS-LASIK were significantly higher compared with the SBK group at 1 month after surgery [0.51 (0.18, 0.93) vs. 0.77 (0.40, 1.22), P = 0.019]. The surgical satisfaction questionnaire scores of the SBK group and the FS-LASIK group were 9.8 ± 0.8 and 9.8 ± 0.8, respectively, at 1 month, and 9.7 ± 0.9 and 9.7 ± 1.0, respectively, at 3 years (all P > 0.05). Conclusion There were no differences in corneal aberrations and satisfaction between SBK and FS-LASIK procedures at 1 month and 3 years.
Collapse
Affiliation(s)
- Yi Feng
- Shanxi Eye Hospital, Shanxi Eye Hospital, Taiyuan, China
| | - Rui He
- Shanxi Eye Hospital, Shanxi Eye Hospital, Taiyuan, China
| | - Min Qu
- Shanxi Eye Hospital, Shanxi Eye Hospital, Taiyuan, China
| | - Qiuxia Ma
- Shanxi Eye Hospital, Shanxi Eye Hospital, Taiyuan, China
| | - Huiqin Tian
- Shanxi Eye Hospital, Shanxi Eye Hospital, Taiyuan, China
| |
Collapse
|
3
|
Ex-vivo study on the surface quality of corneal lenticule and stroma after low energy femtosecond laser lenticule extraction. Sci Rep 2022; 12:10034. [PMID: 35705567 PMCID: PMC9200215 DOI: 10.1038/s41598-022-13468-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 05/24/2022] [Indexed: 11/26/2022] Open
Abstract
This study aimed to assess the surface quality of cap, stroma and lenticular surfaces created using low-energy femtosecond laser lenticule extraction (Ziemer FEMTO LDV Z8). Twenty-four porcine eyes were divided into four groups (n = 6 each): two with optimal laser power (32%) with posterior curvature equivalent to a spherical correction of -2D and -5D, respectively and the other two with high power (64%) with spherical correction of -2D and -5D respectively. Samples were analysed using scanning electron microscopy (SEM). Surface morphology was evaluated using a standard scoring system; surface relief, surface regularity, extent and position of irregularities were graded by four independent clinicians. Eyes with 32% power and -2D correction had significantly less size of the irregular area than those with -5D; however, no significant difference was found between the two groups with 64% power. When comparing eyes with -2D correction, the size of the irregular area was lesser with 32% power. Surface relief was lesser with -5D correction with 32% power than 64% power. Low-energy femtosecond laser lenticule extraction (Ziemer FEMTO LDV Z8) produces good surface quality results. There is a tendency for smoother surface stromal quality with lower power settings than a higher power.
Collapse
|
4
|
Liu X, Liu C, Lin H, Shao Y, Zhang L, Bi Y. An optional surgical technique for obtaining lamellar donor grafts: a pilot study. BMC Ophthalmol 2022; 22:137. [PMID: 35337290 PMCID: PMC8957127 DOI: 10.1186/s12886-022-02371-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 03/23/2022] [Indexed: 11/23/2022] Open
Abstract
Background To evaluate the surface quality and thickness uniformity of lamellar donor grafts using an optional surgical technique called reversed manual dissection (RMD) in porcine corneas. Methods Twenty-four paired porcine corneas (48 eyes) were numbered 1 to 24 and divided into 6 groups. All left corneas were assigned to conventional manual dissection (CMD), and all right corneas were assigned to RMD. Each group contained 8 corneas. For Groups I, II, and III, 30, 50, and 70% of the entire corneal thickness was dissected using CMD. For groups IV, V, and VI, 70, 50, and 30% of the entire corneal thickness was dissected using RMD. The residual stromal thickness was examined by anterior segment optical coherence tomography (ASOCT) to assess the thickness uniformity and scanning electron microscopy (SEM) to assess the surface quality. Results The thickness uniformity of the lamellar grafts between each paired group was not significantly different (p > 0.05). The qualitative surface roughness grading (QiSR) evaluated by masked observers through SEM was significantly higher in the RMD groups (p < 0.001). The quantitative surface roughness grading (QnSR) acquired from the Mountains software was significantly lower in the RMD groups (p < 0.001). Conclusions RMD is an optional surgical technique for obtaining porcine lamellar grafts. The thickness uniformity of RMD is comparable to that of CMD, and a smoother surface with fewer ridges and roughness is achieved compared to CMD.
Collapse
Affiliation(s)
- Xin Liu
- Department of Ophthalmology, Tongji Hospital, School of Medicine, Tongji University, No. 389, Xincun Road, Putuo District, Shanghai, 200092, China.,Department of Ophthalmology, Guizhou Provincial People's Hospital, Guiyang, Guizhou, China
| | - Chunyu Liu
- Department of Ophthalmology, Tongji Hospital, School of Medicine, Tongji University, No. 389, Xincun Road, Putuo District, Shanghai, 200092, China
| | - Hui Lin
- Department of Ophthalmology, Tongji Hospital, School of Medicine, Tongji University, No. 389, Xincun Road, Putuo District, Shanghai, 200092, China
| | - Yuting Shao
- Department of Ophthalmology, Tongji Hospital, School of Medicine, Tongji University, No. 389, Xincun Road, Putuo District, Shanghai, 200092, China
| | - Li Zhang
- Department of Ophthalmology, Tongji Hospital, School of Medicine, Tongji University, No. 389, Xincun Road, Putuo District, Shanghai, 200092, China.
| | - Yanlong Bi
- Department of Ophthalmology, Tongji Hospital, School of Medicine, Tongji University, No. 389, Xincun Road, Putuo District, Shanghai, 200092, China. .,Tongji Eye Institute, Tongji University School of Medicine, Shanghai, China.
| |
Collapse
|
5
|
Veloso AWCA, van Zyl T, Jurkunas U, Pineda R. Femtosecond laser-assisted anterior lamellar keratoplasty with suboptimal outcomes: a case series. REVISTA BRASILEIRA DE OFTALMOLOGIA 2021. [DOI: 10.37039/1982.8551.20210049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
6
|
Flap Thickness and the Risk of Complications in Mechanical Microkeratome and Femtosecond Laser In Situ Keratomileusis: A Literature Review and Statistical Analysis. Diagnostics (Basel) 2021; 11:diagnostics11091588. [PMID: 34573930 PMCID: PMC8468565 DOI: 10.3390/diagnostics11091588] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 08/11/2021] [Accepted: 08/17/2021] [Indexed: 11/16/2022] Open
Abstract
INTRODUCTION A recent Cochrane review found no difference in visual acuity outcomes between femtosecond-assisted laser in situ keratomileusis (LASIK) and LASIK using mechanical microkeratomes (MMKs). This study compares the flap thickness and risk of complications related to flap creation using femtosecond lasers and MMKs. METHODS PubMed and the Web of Science are used to search the medical literature. An extensive search is performed to identify the flap thickness and complications of LASIK as reported up to 15 July 2021. The following keywords are used in various combinations: Corneal flap, femtosecond laser, laser in situ keratomileusis, laser-assisted in situ keratomileusis, LASIK, mechanical microkeratome. RESULTS After removing duplicates and irrelevant studies, 122 articles were included for review. Pooled differences for intended vs. postoperative flap thickness using MMKs and femtosecond laser were -4.07 μm (95% CI: -19.55, 3.24 μm) in studies on the MMK and 5.43 μm (95% CI: 2.30, 7.84 μm; p < 0.001), respectively. After removing the studies evaluating outcomes of the old generation Hansatome MMKs (which had a significantly greater variation of flap thickness), the pooled difference for newer MMKs was 4.97 μm (95% CI: 0.35, 9.58 μm; p < 0.001), but the results still favored the femtosecond laser. Uncommon and mild complications unique for the femtosecond LASIK are epithelial gas breakthrough, opaque bubble layer, transient light sensitivity syndrome, and rainbow glare. A single study reported a very low, but stastically different risk of postoperative flap slippage (0.033% for MMK LASIK, and 0.003% for femtosecond LASIK, respectively). CONCLUSION In both manual microkeratome and femtosecond LASIK, intra- and postoperative complications were uncommon. The evidence of the superiority of one technique in terms of complications over another cannot be indisputably stated.
Collapse
|
7
|
Gros-Otero J, Ketabi S, Cañones-Zafra R, Garcia-Gonzalez M, Villa-Collar C, Casado S, Teus MA. Corneal stromal roughness after VisuMax and Intralase femtosecond laser photodisruption: An atomic force microscopy study. PLoS One 2021; 16:e0252449. [PMID: 34043738 PMCID: PMC8158881 DOI: 10.1371/journal.pone.0252449] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Accepted: 05/16/2021] [Indexed: 11/26/2022] Open
Abstract
Purpose To compare the induced corneal stromal bed roughness measured with atomic force microscopy (AFM) after LASIK flap creation with the IntraLase 60 kHz and the VisuMax femtosecond laser platforms. Methods Three freshly enucleated porcine eyes were operated with each femtosecond laser in this experimental study. Standard LASIK treatment parameters were used for the experiment. After LASIK flap creation, the corneal stromal roughness was assessed using a JPK NanoWizard II® AFM in contact mode immersed in liquid. Olympus OMCL-RC800PSA commercial silicon nitride cantilever tips were used. Surface measurements were made in 10 regions of the central cornea of each sample measuring 20 x 20 microns, at 512 x 512 point resolution. Roughness was measured using the root-mean-square (RMS) value within the given regions. Results Measurements from 30 regions of the 3 eyes (10 measurements per eye) in the Intralase (FS1) group, and 30 regions of the 3 eyes (10 measurements per eye) in the VisuMax (FS2) group were analyzed. There was a statistically significant difference in mean ± standard deviation RMS values between the FS1 and the FS2 groups (360 ± 120 versus 230 ± 100 nm respectively; P< 0.00001). Conclusion This AFM study indicates that the surface of the stromal bed after LASIK flap creation is smoother in the FS2 group than the FS1 group.
Collapse
Affiliation(s)
- Juan Gros-Otero
- Clínica Rementería, Madrid, Spain
- Universidad CEU San Pablo, Madrid, Spain
- * E-mail:
| | - Samira Ketabi
- Hospital Universitario Príncipe de Asturias, Alcalá de Henares, Madrid, Spain
| | | | | | | | - Santiago Casado
- IMDEA Nanociencia, Madrid, Spain
- Facultad de Ciencia e Ingeniería de Alimentos, Universidad Técnica de Ambato, Ambato, Ecuador
| | - Miguel A. Teus
- Hospital Universitario Príncipe de Asturias, Alcalá de Henares, Madrid, Spain
- Clínica Novovisión, Madrid, Spain
| |
Collapse
|
8
|
Zhao Y, Qian Y, Chen X, Zhou X, Qin B, Zhou X. Comparison of posterior corneal elevation after SMILE and FS-LASIK in correcting myopia over -9.0 diopters. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:373. [PMID: 33842594 PMCID: PMC8033304 DOI: 10.21037/atm-20-5165] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background To compare the changes in posterior corneal elevation after small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in correcting myopia over -9 diopters (D). Methods In this prospective comparative study, 82 eyes of 82 patients scheduled for refractive correction were recruited. Eyes were randomly assigned to the SMILE group (45 eyes, -10.43±0.92 D) or FS-LASIK group (37 eyes, -10.97±1.37 D). The posterior corneal surface was measured using a Scheimpflug camera (Pentacam, Oculus, Germany) preoperatively and at 1 day, 1 month, and 6 months after surgery. Posterior corneal elevation in the central point and central 4-mm area, and in various optical zones above the best-fit sphere, was analyzed. A P value of less than 0.05 was considered statistically significant. Results All surgeries were completed successfully. The safety index and efficacy index were 1.20 and 1.00, respectively, in the SMILE group, and was 1.10 and 0.90, respectively, in the FS-LASIK group. No significant difference existed in all analyzed data before and at 6 months after surgery in both the SMILE group and the FS-LASIK group. Changes in posterior corneal elevation after FS-LASIK were greater than after SMILE, with no statistical significance (P≥0.07). In the SMILE group, residual bed thickness was found to be moderately negatively correlated with changes in the elevation in the central area (P≤0.045); whereas it was positively correlated in the peripheral area (P=0.002). Conclusions SMILE and FS-LASIK presented stable posterior corneal surface in correction of myopia over -9.0 D at the follow-up visit of 6 months.
Collapse
Affiliation(s)
- Yu Zhao
- Department of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yishan Qian
- Department of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xun Chen
- Department of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xueyi Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Bing Qin
- Department of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
9
|
Freidank S, Vogel A, Linz N. Optical Vortex Beam for Gentle and Ultraprecise Intrastromal Corneal Dissection in Refractive Surgery. Transl Vis Sci Technol 2020; 9:22. [PMID: 33024615 PMCID: PMC7521178 DOI: 10.1167/tvst.9.10.22] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 08/20/2020] [Indexed: 11/24/2022] Open
Abstract
Purpose We introduce a novel focus shaping concept for intrastromal corneal dissection that facilitates cleavage along corneal lamellae, and we analyze laser-tissue interactions governing cutting effectiveness and mechanical side effects. Methods Focus shaping was achieved by a spiral phase plate that converts an incident Gaussian beam into a Laguerre-Gaussian beam with a helical phase. Such vortex beams have zero intensity at their center, are propagation invariant, and possess a ring focus equal in length to the Gaussian focus but with a larger diameter. Cutting precision and the required absorbed energy for flap dissection were compared for Gaussian and vortex beams on ex vivo porcine corneal specimens at pulse durations between 480 fs and 9 ps. Cutting quality and bubble formation were characterized by scanning electron microscopy and macro photography. Results With the vortex beam, the cuts were much smoother. Bubble formation was markedly reduced because cutting can be performed close to the bubble threshold, whereas with the Gaussian beam energies well above threshold are needed. Although the incident energy at the flap dissection threshold was slightly larger for the vortex beam, the absorbed energy was much smaller and contributed more effectively to cutting. This reduced plasma-induced pressure more than sevenfold. Conclusions The vortex beam approach for corneal dissection is a simple, versatile, and cost-effective way of improving the precision of refractive surgery while reducing bubble formation and pressure-related mechanical side effects. Translational Relevance Phase plates for propagation invariant vortex beams are easily implemented in the beam path of next-generation clinical devices.
Collapse
Affiliation(s)
| | - Alfred Vogel
- Institute of Biomedical Optics, University of Luebeck, Luebeck, Germany
| | - Norbert Linz
- Institute of Biomedical Optics, University of Luebeck, Luebeck, Germany
| |
Collapse
|
10
|
Chen H, Tian L, Le Q, Zhao F, Zhao Y, Chen Y, Yang Y, Hong J, Xu J. Femtosecond laser-assisted Descemet’s stripping endothelial keratoplasty: a prospective study of 6-month visual outcomes, corneal thickness and endothelial cell loss. Int Ophthalmol 2020; 40:2065-2075. [DOI: 10.1007/s10792-020-01383-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2019] [Accepted: 04/10/2020] [Indexed: 11/28/2022]
|
11
|
Zhao Y, Zhao F, Han T, Zhao J, Zhou X. A pilot study: lenticule quality of hyperopic small incision lenticule extraction (SMILE) in rabbits. BMC Ophthalmol 2020; 20:158. [PMID: 32306923 PMCID: PMC7169024 DOI: 10.1186/s12886-020-01432-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Accepted: 04/13/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To evaluate lenticule surface characteristics of small incision lenticule extraction (SMILE) for hyperopia correction in rabbits. METHODS The left and right eyes of 8 rabbits were divided into two groups. The right eyes were assigned to a myopia group, and the left eyes to a hyperopia group. The rabbits received SMILE procedures with + 3.00 D and - 3.00 D correction for the hyperopia and myopia groups, respectively. Extracted lenticules were examined via scanning electron microscopy. Lenticules from odd-numbered rabbits were accessed with the anterior surface, and lenticules from even-numbered rabbits were observed with the posterior surface. A previously established scoring system was used to evaluate lenticule surface characteristics. Statistical analysis was conducted to compare the scores between the two groups. RESULTS All procedures were performed successfully, and the lenticules were extracted smoothly. One myopia lenticule that was facing downward was handled failed in preparation for imaging, thus 15 lenticules were ultimately graded. Twelve lenticules exhibited smooth surfaces, and regularly arranged tissue bridges were observed in almost all regions. Three lenticules exhibited a partially rough surface and irregularities affecting more than 10% of the lenticules (2 in the hyperopia group and 1 in the myopia group). Rough lenticules occurred in twice as many lenticules in the hyperopia group compared to the myopia group. CONCLUSIONS Scan quality of lenticules after SMILE for hyperopia correction is comparable to that of myopia lenticules. The shape of hyperopic lenticule may increase the difficulty of surgical manipulation and result in surface roughness.
Collapse
Affiliation(s)
- Yu Zhao
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, PR China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Feng Zhao
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, PR China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.,Department of Ophthalmology, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Tian Han
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, PR China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jing Zhao
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, PR China.,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, 83 Fenyang Road, Shanghai, 200031, PR China. .,NHC Key Laboratory of Myopia (Fudan University); Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. .,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
| |
Collapse
|
12
|
Weng S, Xiang D, Lin L, Lin H, Liu F, Liu Q. Optimal Parameters of Scanning Mode in Small Incision Lenticule Extraction (SMILE): Clinical Results and Ultrastructural Analysis. J Refract Surg 2020; 36:34-41. [DOI: 10.3928/1081597x-20191114-02] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Accepted: 11/14/2019] [Indexed: 11/20/2022]
|
13
|
Gros-Otero J, Ketabi S, Cañones-Zafra R, Garcia-Gonzalez M, Parafita-Fernandez A, Villa-Collar C, Casado S, Teus M. Analysis of corneal stromal roughness after iFS 150 kHz and LenSx femtosecond LASIK flap creation in porcine eyes. Graefes Arch Clin Exp Ophthalmol 2019; 257:2665-2670. [PMID: 31650272 DOI: 10.1007/s00417-019-04497-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 09/20/2019] [Accepted: 09/23/2019] [Indexed: 10/25/2022] Open
Abstract
PURPOSE To describe and compare the stromal bed roughness obtained after laser in situ keratomileusis (LASIK) flap creation using a corneal femtosecond laser platform (iFS 150) and a "dual" femtosecond (FS) laser platform (LenSx). METHODS This ex vivo experimental study was conducted in an animal model using 12 freshly enucleated porcine eyes, six with each femtosecond laser. The standard laser treatment parameters were used for the experiment. After LASIK flap creation, the corneal stromal roughness was assessed using atomic force microscopy (AFM) in contact mode immersed in liquid. In each sample, surface measurements were obtained in 60 regions of six eyes per FS laser in 10 20 × 20-micron areas of the central corneal stroma at 512 × 512-point resolution. The surface roughness was measured and the root-mean-square (RMS) values of the roughness were obtained. RESULTS The mean RMS ± standard deviation values were 430 ± 150 nm for the corneal femtosecond laser platform and 370 ± 100 nm for the dual FS laser platform (P < 0.011). CONCLUSIONS In this experimental study with AFM, we found smoother stromal beds after LASIK flap creation with LenSx compared to iFS 150 kHz. Further studies are needed to understand visual implications of the differences found.
Collapse
Affiliation(s)
- Juan Gros-Otero
- Clínica Rementería, Calle Almagro, 36, 28010, Madrid, Spain. .,Universidad CEU San Pablo, Madrid, Spain.
| | - Samira Ketabi
- Hospital Universitario Príncipe de Asturias, Madrid, Spain
| | | | - Montserrat Garcia-Gonzalez
- Clínica Rementería, Calle Almagro, 36, 28010, Madrid, Spain.,Clínica Novovisión, Madrid, Spain.,Universidad Europea de Madrid, Madrid, Spain
| | | | | | - Santiago Casado
- Facultad de Ciencia e Ingeniería de Alimentos, Universidad Técnica de Ambato, Ambato, Ecuador.,IMDEA Nanociencia, Madrid, Spain
| | - Miguel Teus
- Hospital Universitario Príncipe de Asturias, Madrid, Spain.,Clínica Novovisión, Madrid, Spain
| |
Collapse
|
14
|
Nishisako S, Aoki D, Sasaki C, Higa K, Shimazaki J. Comparison of Artificial Anterior Chamber Internal Pressures and Cutting Systems for Descemet's Stripping Automated Endothelial Keratoplasty. Transl Vis Sci Technol 2018; 7:11. [PMID: 30510855 PMCID: PMC6262888 DOI: 10.1167/tvst.7.6.11] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 09/23/2018] [Indexed: 01/24/2023] Open
Abstract
Purpose To optimize methods of preparing donor cornea tissue for Descemet's stripping automated endothelial keratoplasty (DSAEK), we compared five experimental conditions with different internal pressures and cutting systems. Methods The artificial anterior chamber internal pressure (IP) was set at 100 or 200 mm Hg. The microkeratome cut was performed with or without an artificial chamber pressurizer (ACP), using a CBm turbine (CBm) or one use-plus automated (OUP-A). Thirty human research corneas were divided into five groups, and compared after the cut with donor tissue quality parameters, including cutting depth, graft uniformity, cell evaluation, and smoothness of the stromal surface. Results The smallest variation in mean cut depth was observed in the condition, which had IP of 200 mm Hg used ACP and OUP-A. In experimental groups cut using CBm, significantly more consistent thicknesses were made at an IP of 200 than 100 mm Hg. There were no statistically significant differences among the groups in either endothelial cell density or cell viable assay results after cuts. Using an IP of 200 mm Hg with ACP and CBm produced the roughest stromal surface, and the roughness grading scores showed a positive correlation with the percentage of cut depth. Conclusions An IP of 200 mm Hg was the best setting for DSAEK grafts with high predictability of cut depth and uniformity of graft thickness without endothelial cell damage. Translational Relevance For successful DSAEK, it is recommended that a set internal pressure of 200 mm Hg be used during microkeratome cutting for donor tissue preparation.
Collapse
Affiliation(s)
- Sota Nishisako
- Cornea Center and Eye Bank, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Dai Aoki
- Cornea Center and Eye Bank, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Chiaki Sasaki
- Cornea Center and Eye Bank, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Kazunari Higa
- Cornea Center and Eye Bank, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Jun Shimazaki
- Cornea Center and Eye Bank, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| |
Collapse
|
15
|
Hammer CM, Kunert KS, Zhang Y, Lörner J, Wüllner C, Rothuber EL, Paulsen F, Seiler T. Interface morphology and gas production by a refractive 347 nm ultraviolet femtosecond laser: Comparison with established laser systems. J Cataract Refract Surg 2018; 44:1371-1377. [DOI: 10.1016/j.jcrs.2018.05.030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 03/13/2018] [Accepted: 05/25/2018] [Indexed: 10/28/2022]
|
16
|
Farid M, Rhee MK, Akpek EK, Amescua G, Garcia-Ferrer FJ, Lin A, Varu DM, Musch DC, Mah FS, Dunn SP. Corneal Edema and Opacification Preferred Practice Pattern®. Ophthalmology 2018; 126:P216-P285. [PMID: 30366795 DOI: 10.1016/j.ophtha.2018.10.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Accepted: 10/09/2018] [Indexed: 12/16/2022] Open
Affiliation(s)
- Marjan Farid
- Gavin Herbert Eye Institute, Department of Ophthalmology, University of California, Irvine, California
| | - Michelle K Rhee
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai, New York, New York
| | - Esen K Akpek
- The Wilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland
| | - Guillermo Amescua
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
| | | | - Amy Lin
- John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | | | - David C Musch
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, Michigan
| | - Francis S Mah
- Departments of Cornea and External Diseases, Scripps Clinic Torrey Pines, La Jolla, California
| | | | | |
Collapse
|
17
|
Weng S, Yang X, Liu F, Lin H, Liu M, Liu Q. Development of a liquid dissection technique for small-incision lenticule extraction: Clinical results and ultrastructural evaluation. J Cataract Refract Surg 2018; 44:1080-1089. [PMID: 30060900 DOI: 10.1016/j.jcrs.2018.06.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Accepted: 06/04/2018] [Indexed: 11/16/2022]
Abstract
PURPOSE To determine the effect of a liquid dissection technique on clinical outcomes with ultrastructural analysis of the lenticule surface in small-incision lenticule extraction (SMILE). SETTING Zhongshan Ophthalmic Center, Guangzhou, China. DESIGN Prospective case series. METHODS Consecutive patients with myopia scheduled for small-incision lenticule extraction were included. The liquid dissection technique was performed in 1 eye and the traditional dissection technique was performed in the other eye by randomized assignment. Ophthalmic examinations were evaluated preoperatively and at different timepoint follow-ups after small-incision lenticule extraction. Ten human corneal lenticules were analyzed using scanning electron microscopy. RESULTS The study comprised 29 patients (58 eyes). Uncorrected distance visual acuity (logarithm of the minimum angle of resolution) postoperative measurements at 2 and 4 hours were significantly better in the liquid dissection group than in the traditional dissection group (P < .001 and P = .001, respectively); however, there were no significant differences between the 2 groups at 1 day, 1 week, and 1 month postoperatively. Compared with the traditional dissection technique, the liquid dissection technique induced significantly fewer corneal aberrations at 2 hours and 1 month after the procedures (P = .031 and P = .016, respectively), the postoperative contrast sensitivity in the liquid dissection group was significantly higher after 1 day (P = .01). The liquid dissection samples showed smoother lenticule surfaces compared with the traditional dissection samples qualitatively and quantitatively (P = .004 and P < .001, respectively). CONCLUSION The liquid dissection technique was helpful in facilitating better visual acuity recovery and produced smooth cuts in the early postoperative period.
Collapse
Affiliation(s)
- Shengbei Weng
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Centre, Sun Yat-sen University, Guangzhou, China
| | - Xiaonan Yang
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Centre, Sun Yat-sen University, Guangzhou, China
| | - Fang Liu
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Centre, Sun Yat-sen University, Guangzhou, China
| | - Haiqin Lin
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Centre, Sun Yat-sen University, Guangzhou, China
| | - Manli Liu
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Centre, Sun Yat-sen University, Guangzhou, China
| | - Quan Liu
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Centre, Sun Yat-sen University, Guangzhou, China.
| |
Collapse
|
18
|
Vukich JA, Durrie DS, Pepose JS, Thompson V, van de Pol C, Lin L. Evaluation of the small-aperture intracorneal inlay: Three-year results from the cohort of the U.S. Food and Drug Administration clinical trial. J Cataract Refract Surg 2018; 44:541-556. [DOI: 10.1016/j.jcrs.2018.02.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 02/20/2018] [Accepted: 02/28/2018] [Indexed: 10/16/2022]
|
19
|
Evaluation of Human Corneal Lenticule Quality After SMILE With Different Cap Thicknesses Using Scanning Electron Microscopy. Cornea 2018; 37:59-65. [PMID: 29053560 DOI: 10.1097/ico.0000000000001404] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the surface characteristics of lenticules created by small-incision lenticule extraction (SMILE) with different cap thicknesses. METHODS This prospective study included 20 consecutive patients who underwent bilateral SMILE. Surface regularity of the extracted corneal lenticule was analyzed using scanning electron microscopy (SEM) combined with 2 methods: qualitative and quantitative regularity. Qualitative regularity of SEM images was graded by masked observers using an established scoring system. Quantitative regularity of SEM images was assessed by counting the total number and areas of tissue bridges using Image-Pro Plus software. Four different cap thickness of 120, 130, 140, and 150 μm were compared. Refractive outcomes of patients were measured at baseline and 1 month after surgery. RESULTS As 10 specimens were not analyzable, only 30 eyes were included. Postoperatively, all eyes had postoperative uncorrected distance visual acuity of 20/20 or better; 43% had an unchanged corrected distance visual acuity; 43% gained 1 line; 10% lost 1 line. Ultrastructurally, surface irregularity was primarily caused by tissue bridges. The average surface regularity score obtained was 10.87 ± 2.40 for 120 μm, 10.78 ± 2.60 for 130 μm, 8.76 ± 2.16 for 140 μm, and 8.70 ± 2.66 for 150 μm (P < 0.001). The total number and areas of tissue bridges of 120 to 130 μm were significantly less than 140 to 150 μm (P < 0.05). Surface regularity decreased as cap thickness increased (P < 0.05). CONCLUSIONS There is smoother appearance of the lenticular surface as seen through SEM when a thin cap is created compared with a thick cap qualitatively and quantitatively.
Collapse
|
20
|
Jumelle C, Hamri A, Egaud G, Mauclair C, Reynaud S, Dumas V, Pereira S, Garcin T, Gain P, Thuret G. Comparison of four methods of surface roughness assessment of corneal stromal bed after lamellar cutting. BIOMEDICAL OPTICS EXPRESS 2017; 8:4974-4986. [PMID: 29188095 PMCID: PMC5695945 DOI: 10.1364/boe.8.004974] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 08/30/2017] [Accepted: 09/02/2017] [Indexed: 06/07/2023]
Abstract
Corneal lamellar cutting with a blade or femtosecond laser (FSL) is commonly used during refractive surgery and corneal grafts. Surface roughness of the cutting plane influences postoperative visual acuity but is difficult to assess reliably. For the first time, we compared chromatic confocal microscopy (CCM) with scanning electron microscopy, atomic force microscopy (AFM) and focus-variation microscopy (FVM) to characterize surfaces of variable roughness after FSL cutting. The small area allowed by AFM hinders conclusive roughness analysis, especially with irregular cuts. FVM does not always differentiate between smooth and rough surfaces. Finally, CCM allows analysis of large surfaces and differentiates between surface states.
Collapse
Affiliation(s)
- Clotilde Jumelle
- Corneal Graft Biology, Engineering and Imaging Laboratory, BiiGC, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, 10 rue de la Marandière, 42055 Saint-Etienne Cédex 02, France
| | - Alina Hamri
- GIE-Manutech-Ultrafast Surface Design, 20 rue Benoit Lauras, 42000 Saint-Etienne, France
| | - Gregory Egaud
- GIE-Manutech-Ultrafast Surface Design, 20 rue Benoit Lauras, 42000 Saint-Etienne, France
| | - Cyril Mauclair
- GIE-Manutech-Ultrafast Surface Design, 20 rue Benoit Lauras, 42000 Saint-Etienne, France
- Hubert Curien Laboratory, UMR-CNRS 5516, Jean Monnet University, 18 rue Benoit Lauras, 42000 Saint-Etienne, France
| | - Stephanie Reynaud
- Hubert Curien Laboratory, UMR-CNRS 5516, Jean Monnet University, 18 rue Benoit Lauras, 42000 Saint-Etienne, France
| | - Virginie Dumas
- Ecole Nationale d’Ingénieurs de Saint-Etienne (ENISE), Laboratoire de Tribologie et Dynamique des Systèmes, UMR 5513 CNRS, 58 rue Jean Parot, 42023 Saint-Etienne, France
| | - Sandrine Pereira
- Eye Bank, French Blood Center, 25 boulevard Pasteur, 42023 Saint-Etienne, France
| | - Thibaud Garcin
- Corneal Graft Biology, Engineering and Imaging Laboratory, BiiGC, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, 10 rue de la Marandière, 42055 Saint-Etienne Cédex 02, France
- Ophthalmology Department, University Hospital, avenue Albert Raimond, 42055 Saint-Etienne Cédex 02, France
| | - Philippe Gain
- Corneal Graft Biology, Engineering and Imaging Laboratory, BiiGC, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, 10 rue de la Marandière, 42055 Saint-Etienne Cédex 02, France
- Ophthalmology Department, University Hospital, avenue Albert Raimond, 42055 Saint-Etienne Cédex 02, France
| | - Gilles Thuret
- Corneal Graft Biology, Engineering and Imaging Laboratory, BiiGC, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, 10 rue de la Marandière, 42055 Saint-Etienne Cédex 02, France
- Ophthalmology Department, University Hospital, avenue Albert Raimond, 42055 Saint-Etienne Cédex 02, France
- Institut Universitaire de France, 1 rue Descartes, 75231 Paris, France
| |
Collapse
|
21
|
Comparison of femtosecond and excimer laser platforms available for corneal refractive surgery. Curr Opin Ophthalmol 2016; 27:316-22. [PMID: 27031540 DOI: 10.1097/icu.0000000000000268] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE OF REVIEW The evolution of laser technology has left today's refractive surgeon with a choice between multiple laser platforms. The purpose of this review is to compare currently available femtosecond and excimer laser platforms, providing a summary of current evidence. RECENT FINDINGS Femtosecond lasers create LASIK flaps with better accuracy, uniformity, and predictability than mechanical microkeratomes. Newer higher-frequency femtosecond platforms elicit less inflammation, producing better visual outcomes. SMILE achieved similar safety, efficacy, and predictability as LASIK with greater preservation of corneal nerves and biomechanical strength. The emergence of wavefront technology has resulted in improved excimer laser treatments. Comparisons of wavefront-guided and wavefront-optimized treatments suggest that there is an advantage to using wavefront-guided platforms in terms of visual acuity and quality of vision. Topography-guided ablations are another well tolerated and effective option, especially in eyes with highly irregular corneas. SUMMARY Advances in femtosecond and excimer laser technology have not only improved the safety and efficacy of refractive procedures, but have also led to the development of promising new treatment modalities, such as SMILE and the use of wavefront-guided and topography-guided ablation. Future studies and continued technological progress will help to better define the optimal use of these treatment platforms.
Collapse
|
22
|
Fawzy F, Wahba SS, Fawzy N. Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis. Clin Ophthalmol 2016; 10:2051-2053. [PMID: 27799731 PMCID: PMC5079693 DOI: 10.2147/opth.s117306] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
We present an observational sign that ensures perfect alignment during femtosecond laser-assisted in situ keratomileusis (FS LASIK). Alignment is assured when a microsponge is used to dry the flap and the area of dryness exceeds the area of direct touch of the microsponge. The area might even reach the whole circumference of the flap at the first touch. This sign of alignment can be explained by microcapillary action. This sign was not elicited in flaps created by a microkeratome.
Collapse
Affiliation(s)
- Fathy Fawzy
- Al Watany Eye Hospital; Ophthalmology Department, Military Medical Academy
| | - Sherine S Wahba
- Al Watany Eye Hospital; Ophthalmology Department, Ain Shams University, Cairo, Egypt
| | - Nader Fawzy
- Al Watany Eye Hospital; Sehkraft Augenzentrum, Cologne, Germany
| |
Collapse
|
23
|
Shetty R, Nagaraja H, Veluri H, Shivanna Y, Kugar T, Nujits R, Shetty B. Sutureless femtosecond anterior lamellar keratoplasty: a 1-year follow-up study. Indian J Ophthalmol 2016; 62:923-6. [PMID: 25370393 PMCID: PMC4244737 DOI: 10.4103/0301-4738.143928] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Aim: To study the safety and efficacy of sutureless femtosecond anterior lamellar keratoplasty (FALK) in patients with corneal stromal opacities. Materials and Methods: Eleven eyes of 11 consecutive patients with corneal stromal opacities involving < 250 μ due to various pathologies were included in the study. Preoperatively, all underwent anterior segment imaging with spectral domain optical coherence tomography (SD-OCT) (Bioptigen Inc., Durham, North Carolina, USA) to measure the depth of the stromal opacity. All patients underwent FALK, and bandage contact lens was placed for a period of 2 weeks. Postoperatively, uncorrected visual acuity, best corrected visual acuity (BCVA), and SD-OCT evaluation were performed. Results: All patients showed significant improvement in BCVA. The mean postoperative BCVA (in decimals) improved from 0.11 ± 0.06 preoperatively to 0.59 ± 0.08. There were no intraoperative or significant postoperative complications that were noticed. Conclusion: FALK is a safe and effective alternative to deep anterior lamellar keratoplasty or penetrating keratoplasty in the treatment of anterior stromal opacities.
Collapse
Affiliation(s)
| | - Harsha Nagaraja
- Department of Cornea and Refractive Surgery, Narayana Nethralaya Eye Hospital, Bengaluru, Karnataka, India
| | | | | | | | | | | |
Collapse
|
24
|
Sáles CS, Manche EE. Comparison of self-reported quality of vision outcomes after myopic LASIK with two femtosecond lasers: a prospective, eye-to-eye study. Clin Ophthalmol 2016; 10:1691-9. [PMID: 27621589 PMCID: PMC5012845 DOI: 10.2147/opth.s111328] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Purpose To compare self-reported quality of vision (QoV) outcomes after myopic LASIK (laser-assisted in situ keratomileusis) with two femtosecond lasers. Design Prospective, randomized, eye-to-eye study. Methods Consecutive myopic patients were treated with wavefront-guided LASIK bilaterally. Eyes were randomized according to ocular dominance. The flap of one eye was made with the IntraLase FS 60 kHz femtosecond laser with a conventional 70° side-cut, and the flap of the fellow eye was made with the IntraLase iFS 150 kHz femtosecond laser with an inverted 130° side-cut. Patients completed the validated, Rasch-tested, linear-scaled 30-item QoV questionnaire preoperatively and at Months 1, 3, 6, and 12. Results The study enrolled 120 fellow eyes in 60 patients. None of the measured QoV parameters exhibited statistically significant differences between the groups preoperatively or at any postoperative time point. Conclusion Creating LASIK flaps with an inverted side-cut using a 150 kHz femtosecond laser and with a conventional 70° side-cut using a 60 kHz femtosecond laser resulted in no significant differences in self-reported QoV assessed by the QoV questionnaire.
Collapse
Affiliation(s)
| | - Edward E Manche
- Byers eye Institute, stanford University school of Medicine, Palo alto, CA, USA
| |
Collapse
|
25
|
Varga Z, Bergin C, Roy S, Nicolas M, Tschuor P, Majo F. Scanning Electronic Microscopy Evaluation of the Roughness of the Stromal Bed After Deep Corneal Cut with the LDV Femtosecond Laser (Z6) (Ziemer) and the ONE Microkeratome (Moria). Curr Eye Res 2016; 41:1302-1309. [PMID: 26881295 DOI: 10.3109/02713683.2015.1119281] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To compare the stromal bed surface quality and the accuracy of dissection depth after deep lamellar cuts using the Leonardo Da Vinci (LDV) femtosecond laser (Z6) and the ONE Microkeratome. METHODS Deep lamellar cuts were performed on nine human donor corneoscleral buttons: five with the LDV femtosecond (FS) laser (Z6) (Ziemer) and four with the ONE Microkeratome (MK) (Moria). Corneal thickness was measured with ultrasound pachymetry before and after the dissection. The Stromal bed quality was evaluated using light microscopy (n = 4) and scanning electron microscopy (SEM) (n = 9). The surface roughness on SEM images was graded on the scale of 1 (smoothest) to 5 (roughest) by four observers, blinded to the method used. Particle analysis on the SEM images was performed in order to have an objective measure of smoothness. RESULTS The achieved dissection depth using the FS laser was 496.4 ± 46.4 µm when attempting 500 µm and 474 ± 60 µm with the microkeratome when attempting 350 µm. Histological evaluation of the corneoscleral buttons by both light and electron microscopy showed significantly smoother surface using the FS laser compared to the microkeratome. There were fewer and smaller particles observed in the SEM images of FS laser cut buttons (p < 0.001).The average observer based score of anterior surface roughness (50×) was 2.2 for the FS laser and 3.9 for the microkeratome dissections (p < 0.001). CONCLUSIONS The LDV femtosecond laser (Z6) platform is capable of creating deep corneal lamellar dissection with smoother surface quality and with more predictable cut depth as compared to the One Microkeratome.
Collapse
Affiliation(s)
- Zsolt Varga
- a Department of Ophthalmology , University of Lausanne, Fondation Asile des Aveugles , Lausanne , Switzerland.,b Department of Clinical Neuroscience , University Hospital of Geneva , Geneva , Switzerland
| | - Ciara Bergin
- a Department of Ophthalmology , University of Lausanne, Fondation Asile des Aveugles , Lausanne , Switzerland
| | | | - Michael Nicolas
- a Department of Ophthalmology , University of Lausanne, Fondation Asile des Aveugles , Lausanne , Switzerland
| | - Patrizia Tschuor
- a Department of Ophthalmology , University of Lausanne, Fondation Asile des Aveugles , Lausanne , Switzerland
| | - François Majo
- a Department of Ophthalmology , University of Lausanne, Fondation Asile des Aveugles , Lausanne , Switzerland
| |
Collapse
|
26
|
Zhao Y, Li M, Sun L, Zhao J, Chen Y, Zhou X. Lenticule Quality After Continuous Curvilinear Lenticulerrhexis in SMILE Evaluated With Scanning Electron Microscopy. J Refract Surg 2015; 31:732-5. [DOI: 10.3928/1081597x-20151029-01] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2014] [Accepted: 08/18/2015] [Indexed: 12/31/2022]
|
27
|
Chan TCY, Cheng GPM, Wang Z, Tham CCY, Woo VCP, Jhanji V. Vector Analysis of Corneal Astigmatism After Combined Femtosecond-Assisted Phacoemulsification and Arcuate Keratotomy. Am J Ophthalmol 2015; 160:250-255.e2. [PMID: 25982969 DOI: 10.1016/j.ajo.2015.05.004] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Revised: 05/07/2015] [Accepted: 05/08/2015] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the outcomes of femtosecond-assisted arcuate keratotomy combined with cataract surgery in eyes with low to moderate corneal astigmatism. DESIGN Retrospective, interventional case series. METHODS This study included patients who underwent combined femtosecond-assisted phacoemulsification and arcuate keratotomy between March 2013 and August 2013. Keratometric astigmatism was evaluated before and 2 months after the surgery. Vector analysis of the astigmatic changes was performed using the Alpins method. RESULTS Overall, 54 eyes of 54 patients (18 male and 36 female; mean age, 68.8 ± 11.4 years) were included. The mean preoperative (target-induced astigmatism) and postoperative astigmatism was 1.33 ± 0.57 diopters (D) and 0.87 ± 0.56 D, respectively (P < .001). The magnitude of error (difference between surgically induced and target-induced astigmatism) (-0.13 ± 0.68 D), as well as the correction index (ratio of surgically induced and target-induced astigmatism) (0.86 ± 0.52), demonstrated slight undercorrection. The angle of error was very close to 0, indicating no significant systematic error of misaligned treatment. However, the absolute angle of error showed a less favorable range (17.5 ± 19.2 degrees), suggesting variable factors such as healing or alignment at an individual level. There were no intraoperative or postoperative complications. CONCLUSIONS Combined phacoemulsification with arcuate keratotomy using femtosecond laser appears to be a relatively easy and safe means for management of low to moderate corneal astigmatism in cataract surgery candidates. Misalignment at an individual level can reduce its effectiveness. This issue remains to be elucidated in future studies.
Collapse
Affiliation(s)
- Tommy C Y Chan
- Hong Kong Eye Hospital, Kowloon, Hong Kong; Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong
| | | | - Zheng Wang
- Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Clement C Y Tham
- Hong Kong Eye Hospital, Kowloon, Hong Kong; Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong
| | | | - Vishal Jhanji
- Hong Kong Eye Hospital, Kowloon, Hong Kong; Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong.
| |
Collapse
|
28
|
Aristeidou A, Taniguchi EV, Tsatsos M, Muller R, McAlinden C, Pineda R, Paschalis EI. The evolution of corneal and refractive surgery with the femtosecond laser. EYE AND VISION 2015; 2:12. [PMID: 26605365 PMCID: PMC4655461 DOI: 10.1186/s40662-015-0022-6] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2015] [Accepted: 06/20/2015] [Indexed: 01/12/2023]
Abstract
The use of femtosecond lasers has created an evolution in modern corneal and refractive surgery. With accuracy, safety, and repeatability, eye surgeons can utilize the femtosecond laser in almost all anterior refractive procedures; laser in situ keratomileusis (LASIK), small incision lenticule extraction (SMILE), penetrating keratoplasty (PKP), insertion of intracorneal ring segments, anterior and posterior lamellar keratoplasty (Deep anterior lamellar keratoplasty (DALK) and Descemet's stripping endothelial keratoplasty (DSEK)), insertion of corneal inlays and cataract surgery. As the technology matures, it will push surgical limits and open new avenues for ophthalmic intervention in areas not yet explored. As we witness the transition from femto-LASIK to femto-cataract surgery it becomes obvious that this innovation is here to stay. This article presents some of the most relevant advances of femtosecond lasers to modern corneal and refractive surgery.
Collapse
Affiliation(s)
| | - Elise V Taniguchi
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, MA USA ; Massachusetts Eye and Ear Infirmary/Schepens Eye Research Institute, Boston Keratoprosthesis Laboratory, Harvard Medical School, Boston, 02114 MA USA
| | | | - Rodrigo Muller
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, MA USA
| | - Colm McAlinden
- Flinders University, Adelaide, South Australia Australia ; Wenzhou Medical University, Wenzhou, Zhejiang China
| | - Roberto Pineda
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, MA USA
| | - Eleftherios I Paschalis
- Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, MA USA ; Massachusetts Eye and Ear Infirmary/Schepens Eye Research Institute, Boston Keratoprosthesis Laboratory, Harvard Medical School, Boston, 02114 MA USA
| |
Collapse
|
29
|
McLaren JW, Bourne WM, Maguire LJ, Patel SV. Changes in Keratocyte Density and Visual Function Five Years After Laser In Situ Keratomileusis: Femtosecond Laser Versus Mechanical Microkeratome. Am J Ophthalmol 2015; 160:163-70. [PMID: 25868758 DOI: 10.1016/j.ajo.2015.04.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2015] [Revised: 04/02/2015] [Accepted: 04/06/2015] [Indexed: 11/19/2022]
Abstract
PURPOSE To determine the effects of keratocyte loss on optical properties and vision after laser in situ keratomileusis (LASIK) with the flap created with a femtosecond laser or a mechanical microkeratome. DESIGN Randomized clinical paired-eye study. METHODS Both eyes of 21 patients received LASIK for myopia or myopic astigmatism. One eye of each patient was randomized by ocular dominance to flap creation with a femtosecond laser and the other eye to flap creation with a mechanical microkeratome. Before LASIK and at 1, 3, and 6 months and 1, 3, and 5 years after LASIK, keratocyte density was measured using confocal microscopy, and high-contrast visual acuity and anterior corneal wavefront aberrations were measured by standard methods. At each visit, all variables were compared between methods of creating the flap and to the same variable before treatment using paired tests with Bonferroni correction for multiple comparisons. RESULTS Keratocyte density in the flap decreased by 20% during the first year after LASIK and remained low through 5 years (P < .001). High-order wavefront aberrations increased and uncorrected visual acuity improved immediately after surgery, but these variables did not change further to 5 years. There were no differences in any variables between treatments. CONCLUSIONS A sustained reduction in keratocyte density does not affect vision or optical properties of the cornea through 5 years after LASIK. The method of creating a LASIK flap does not influence the changes in keratocyte density in the flap.
Collapse
Affiliation(s)
- Jay W McLaren
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota
| | | | - Leo J Maguire
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota
| | - Sanjay V Patel
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota.
| |
Collapse
|
30
|
Liu HH, Hu Y, Cui HP. Femtosecond laser in refractive and cataract surgeries. Int J Ophthalmol 2015; 8:419-26. [PMID: 25938066 DOI: 10.3980/j.issn.2222-3959.2015.02.36] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Accepted: 09/15/2014] [Indexed: 11/02/2022] Open
Abstract
In the past few years, 9 unique laser platforms have been brought to the market. As femtosecond (FS) laser-assisted ophthalmic surgery potentially improves patient safety and visual outcomes, this new technology indeed provides ophthalmologists a reliable new option. But this new technology also poses a range of new clinical and financial challenges for surgeons. We provide an overview of the evolution of FS laser technology for use in refractive and cataract surgeries. This review describes the available laser platforms and mainly focuses on discussing the development of ophthalmic surgery technologies.
Collapse
Affiliation(s)
- Han-Han Liu
- Department of Ophthalmology, Shanghai East Hospital Affiliated to Tongji University, Shanghai 200120, China
| | - Ying Hu
- Department of Ophthalmology, Shanghai East Hospital Affiliated to Tongji University, Shanghai 200120, China
| | - Hong-Ping Cui
- Department of Ophthalmology, Shanghai East Hospital Affiliated to Tongji University, Shanghai 200120, China
| |
Collapse
|
31
|
Wong RCY, Yu M, Chan TCY, Chong KKL, Jhanji V. Longitudinal comparison of outcomes after sub-Bowman keratomileusis and laser in situ keratomileusis: randomized, double-masked study. Am J Ophthalmol 2015; 159:835-45.e3. [PMID: 25681001 DOI: 10.1016/j.ajo.2015.02.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 02/04/2015] [Accepted: 02/04/2015] [Indexed: 11/29/2022]
Abstract
PURPOSE To compare the outcomes of sub-Bowman keratomileusis (100-μm flap) and laser in situ keratomileusis (LASIK) (120-μm flap) using 150-kHz femtosecond laser. DESIGN Randomized, double-masked, contralateral clinical trial. METHODS One hundred patients (200 eyes) with myopia or myopic astigmatism were included. Postoperative examinations were performed at week 1 and months 1, 3, 6, and 12. Main outcome measures included postoperative uncorrected (UCVA) and best-corrected distance visual acuity (BCVA); manifest refraction spherical equivalent; efficacy and safety indices; corneal thickness; and complications. RESULTS The mean age of patients was 33.9 ± 7.9 years. Overall, the preoperative UCVA, BCVA, and manifest refraction spherical equivalent were 1.349 ± 0.332, -0.022 ± 0.033, and -5.81 ± 1.61 diopters, respectively. No significant difference was observed in preoperative (P ≥ .226) or intraoperative parameters (P ≥ .452) between both groups, except residual stromal thickness (P < .001). The UCVA, manifest refraction spherical equivalent, and central corneal thickness stabilized by 1 week, while the thinnest corneal thickness stabilized by 3 months postoperatively. There was no significant difference between both groups for any parameter during all follow-up visits (P ≥ .132) except the 3-month safety index, which was better in the sub-Bowman keratomileusis group (P = .007). Soft opaque bubble layer was noted intraoperatively in 12 cases (7, 100-μm group; 5, 120-μm group; P = .577). No postoperative complications were observed. CONCLUSIONS Our study did not find any differences in the visual and refractive outcomes between femtosecond-assisted sub-Bowman keratomileusis and LASIK. Both surgeries resulted in quick visual recovery as early as 1 week postoperatively.
Collapse
Affiliation(s)
- Rachel Chung Yin Wong
- Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
| | - Marco Yu
- Department of Mathematics and Statistics, Hang Seng Management College, Hong Kong, China
| | - Tommy C Y Chan
- Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China; Hong Kong Eye Hospital, Hong Kong, China
| | - Kelvin K L Chong
- Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
| | - Vishal Jhanji
- Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China; Hong Kong Eye Hospital, Hong Kong, China.
| |
Collapse
|
32
|
Yu CQ, Manche EE. Comparison of 2 femtosecond lasers for flap creation in myopic laser in situ keratomileusis: One-year results. J Cataract Refract Surg 2015; 41:740-8. [DOI: 10.1016/j.jcrs.2014.06.038] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2014] [Revised: 06/02/2014] [Accepted: 06/18/2014] [Indexed: 11/17/2022]
|
33
|
Zhang C, Bald M, Tang M, Li Y, Huang D. Interface quality of different corneal lamellar-cut depths for femtosecond laser-assisted lamellar anterior keratoplasty. J Cataract Refract Surg 2015; 41:827-35. [PMID: 25747165 DOI: 10.1016/j.jcrs.2014.08.031] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2014] [Revised: 07/31/2014] [Accepted: 08/19/2014] [Indexed: 11/30/2022]
Abstract
PURPOSE To evaluate the interface quality of different corneal lamellar-cut depths with the femtosecond laser and determine a feasible range of depth for femtosecond laser-assisted lamellar anterior keratoplasty. SETTING Casey Eye Institute, Portland, Oregon, USA. DESIGN Experimental study. METHODS Full lamellar cuts were made on 20 deepithelialized human cadaver corneas using the femtosecond laser. The cut depth was 17% to 21% (100 μm), 31%, 35%, 38% to 40%, and 45% to 48% of the central stromal thickness. Scanning electron microscopy images of the cap and bed surfaces were subjectively graded for ridge and roughness using a scale of 1 to 5 (1 = best). The graft-host match was evaluated by photography and optical coherence tomography in a simulated procedure. RESULTS The ridge score was correlated with the cut depth (P = .0078, R = 0.58) and better correlated with the percentage cut depth (P = .00024, R = 0.73). The shallowest cuts had the fewest ridges (score 1.25). The 31% cut depth produced significantly fewer ridges (score 2.15) than deeper cuts. The roughness score ranged from 2.19 to 3.08 for various depths. A simulated procedure using a 100 μm host cut and a 177 μm (31%) graft had a smooth interface and flush anterior junction using an inverted side-cut design. CONCLUSIONS The femtosecond laser produced more ridges in deeper lamellar cuts. A depth setting of 31% stromal thickness might produce adequate surface quality for femtosecond laser-assisted lamellar anterior keratoplasty. The inverted side-cut design produced good edge apposition even when the graft was thicker than the host lamellar-cut depth. FINANCIAL DISCLOSURE Proprietary or commercial disclosures are listed after the references.
Collapse
Affiliation(s)
- Chenxing Zhang
- From the Center for Ophthalmic Optics & Lasers (Zhang, Bald, Tang, Li, Huang), Casey Eye Institute and Department of Ophthalmology, Oregon Health & Science University, Portland, Oregon, USA; the Southwest Eye Hospital (Zhang), Third Military Medical University, Chongqing, China
| | - Matthew Bald
- From the Center for Ophthalmic Optics & Lasers (Zhang, Bald, Tang, Li, Huang), Casey Eye Institute and Department of Ophthalmology, Oregon Health & Science University, Portland, Oregon, USA; the Southwest Eye Hospital (Zhang), Third Military Medical University, Chongqing, China
| | - Maolong Tang
- From the Center for Ophthalmic Optics & Lasers (Zhang, Bald, Tang, Li, Huang), Casey Eye Institute and Department of Ophthalmology, Oregon Health & Science University, Portland, Oregon, USA; the Southwest Eye Hospital (Zhang), Third Military Medical University, Chongqing, China
| | - Yan Li
- From the Center for Ophthalmic Optics & Lasers (Zhang, Bald, Tang, Li, Huang), Casey Eye Institute and Department of Ophthalmology, Oregon Health & Science University, Portland, Oregon, USA; the Southwest Eye Hospital (Zhang), Third Military Medical University, Chongqing, China
| | - David Huang
- From the Center for Ophthalmic Optics & Lasers (Zhang, Bald, Tang, Li, Huang), Casey Eye Institute and Department of Ophthalmology, Oregon Health & Science University, Portland, Oregon, USA; the Southwest Eye Hospital (Zhang), Third Military Medical University, Chongqing, China.
| |
Collapse
|
34
|
Moshirfar M, McCaughey MV, Reinstein DZ, Shah R, Santiago-Caban L, Fenzl CR. Small-incision lenticule extraction. J Cataract Refract Surg 2015; 41:652-65. [DOI: 10.1016/j.jcrs.2015.02.006] [Citation(s) in RCA: 104] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2014] [Revised: 10/01/2014] [Accepted: 10/02/2014] [Indexed: 10/23/2022]
|
35
|
|
36
|
Comparison of the anterior capsulotomy edge created by manual capsulorhexis and 2 femtosecond laser platforms: Scanning electron microscopy study. J Cataract Refract Surg 2014; 40:2106-12. [DOI: 10.1016/j.jcrs.2014.10.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2013] [Revised: 03/28/2014] [Accepted: 04/03/2014] [Indexed: 11/18/2022]
|
37
|
Nada O, Marian A, Tran-Khanh N, Buschmann M, Podtetenev M, Vidal F, Costantino S, Brunette I. Effect of corneal hydration on the quality of the femtosecond laser anterior lamellar cut. PLoS One 2014; 9:e98852. [PMID: 24911840 PMCID: PMC4049624 DOI: 10.1371/journal.pone.0098852] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2013] [Accepted: 05/08/2014] [Indexed: 11/19/2022] Open
Abstract
The goal of this study was to assess the effect of corneal hydration on the quality of the femtosecond laser (FSL) anterior lamellar cut. The Visumax FSL was used to dissect an 8-mm-diameter corneal flap in 22 eye bank corneas showing various levels of hydration. The intended ablation depth was 220 µm in all eyes, which corresponded to the maximal depth available with this laser. After the cut, the achieved ablation depth was measured using optical coherence tomography images, flap separability was assessed by measuring the mean force generated to detach the flap, and stromal bed roughness was assessed by measuring the Haralick contrast level on the 1000× scanning electron microscopy images of the ablated surfaces. The preoperative central corneal thickness ranged from 547 to 1104 µm (mean ± SEM: 833 ± 30 µm). A negative correlation was found between the level of corneal hydration and the ablation depth measured in the mid-peripheral cornea (r = -0.626, p = 0.003), the ablation being more superficial in more edematous corneas. The Haralick contrast also tended to increase as a function of corneal hydration (r = 0.416, p = 0.061), suggesting that laser ablation in edematous corneas results in rougher stromal surfaces. These results support the hypothesis that the quality of the FSL lamellar cut decreases as the level of corneal hydration increases. Although FSL is still considered in the field as the tool of the future for corneal dissection, a better understanding of the limits of this tool will be needed before it can replace manual or automated stromal dissection techniques in hydrated corneas.
Collapse
Affiliation(s)
- Ossama Nada
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Québec, Canada
- Ain Shams University, Cairo, Egypt
| | - Anca Marian
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Québec, Canada
| | - Nicolas Tran-Khanh
- Biomedical and Chemical Engineering and Groupe de Recherche en Sciences et Technologies Biomédicales, École Polytechnique, Montreal, Québec, Canada
| | - Michael Buschmann
- Biomedical and Chemical Engineering and Groupe de Recherche en Sciences et Technologies Biomédicales, École Polytechnique, Montreal, Québec, Canada
| | - Michel Podtetenev
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Québec, Canada
- Department of Ophthalmology, University of Montreal, Montreal, Québec, Canada
- Focus Vision Clinic, Verdun, Québec, Canada
| | - François Vidal
- Institut National de la Recherche Scientifique – Centre Énergie Matériaux Télécommunications, Varennes, Québec, Canada
| | - Santiago Costantino
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Québec, Canada
- Department of Ophthalmology, University of Montreal, Montreal, Québec, Canada
| | - Isabelle Brunette
- Maisonneuve-Rosemont Hospital Research Center, Montreal, Québec, Canada
- Department of Ophthalmology, University of Montreal, Montreal, Québec, Canada
- * E-mail:
| |
Collapse
|
38
|
Ziebarth NM, Lorenzo MA, Chow J, Cabot F, Spooner GJR, Dishler J, Hjortdal JØ, Yoo SH. Surface Quality of Human Corneal Lenticules After SMILE Assessed Using Environmental Scanning Electron Microscopy. J Refract Surg 2014; 30:388-93. [DOI: 10.3928/1081597x-20140513-01] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Accepted: 03/04/2014] [Indexed: 11/20/2022]
|
39
|
Effect of 60 kHz and 150 kHz Femtosecond Lasers on Corneal Stromal Bed Surfaces: A Comparative Study. ISRN OPHTHALMOLOGY 2014; 2013:971451. [PMID: 24558610 PMCID: PMC3914225 DOI: 10.1155/2013/971451] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2013] [Accepted: 07/28/2013] [Indexed: 11/18/2022]
Abstract
Purpose. To compare the effect of 60 kHz and 150 kHz femtosecond (FS) laser on the corneal stromal bed surfaces (SBS). Methods. Sixteen human donor corneal tissues unsuitable for transplantation were used. Anterior and posterior lamella was obtained using 60 kHz and 150 kHz FS laser. A standard depth of 400 μ m was set for anterior lamellar keratoplasty (ALK) and endothelial lamellar keratoplasty (ELK). The quality and smoothness of the SBS post-FS laser dissection were graded for statistics. Results. No intraoperative complications were found. The side cuts were straight, and the SBS appeared smoother in cuts obtained using 150 kHz. The average values of the SBS quality of the anterior lamellar cut were found to be 2.25 (±0.28) for 60 kHz and 3.125 (±0.25) for 150 kHz (P = 0.0039). Whereas, 2 (±0.4) for 60 kHz and 2.75 (±0.28) for 150 kHz (P = 0.0273) was the quality observed in endothelial cuts. No significant difference was found between anterior and posterior cuts performed using the same FS laser (60 kHz or 150 kHz) (P > 0.05). Conclusions. The 60 kHz and 150 kHz FS lasers are equally effective in performing lamellar dissection for ALK and ELK. 150 kHz FS laser allows a tighter spot and layer separation which creates a slightly smoother SBS.
Collapse
|
40
|
Zhang ZY, Hoffman MR, Zhou XT, Xu Y, Zhang XR, Chu RY, Chen CD. Refractive change in the adult rabbit eye after corneal relaxation with the femtosecond laser. BMC Ophthalmol 2014; 14:8. [PMID: 24447397 PMCID: PMC3917590 DOI: 10.1186/1471-2415-14-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2012] [Accepted: 12/05/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND A new procedure to correct myopia that does not disturb the cornea in the optical zone and avoids injuring the corneal epithelium could be a key advance in corneal refractive surgery. The aim of this study is to observe the refractive change in the adult rabbits undergoing femtosecond laser-assisted multilayer intrastromal ablation in the mid-periphery of the cornea without injury of epithelium. METHOD The right eyes of 8 New Zealand White adult rabbits were used for the experiments. A 60-kHz femtosecond laser delivery system was used, and three lamellar layers of laser pulses were focused starting at a corneal depth of 180 μm and ending at 90 μm from the surface, with each successive layer placed 45 μm anterior to the previous layer. In the interface of the applanation contact lens cone, a 6-mm diameter aluminum circle was placed at the center to block the laser, limiting ablation to the mid-periphery of the cornea. The laser settings were as follows: spot/line separation, 10 μm; diameter, 8.0 mm; energy for ablating the stroma, 1.3 μJ. An authorefractor was used to assess the manifest refraction. RESULTS Mean spherical equivalent (SE) (mean ± SD, SD: standard deviation) was significantly increased at postoperative week 1 (1.67 ± 0.26 D, p < 0.0001), month 1 (1.65 ± 0.23 D, p < 0.0001), and month 3 (1.60 ± 0.22 D, p < 0.0001) compared to baseline (0.68 ± 0.27 D). Mean spherical equivalent showed no significant change between postoperative week 1 and month 3 (p = 0.1168). CONCLUSION Femtosecond laser-assisted multilayer corneal intrastromal ablation in the mid-periphery may cause a consequent hyperopic shift with no refractive regression.
Collapse
Affiliation(s)
- Zhen-Yong Zhang
- Department of Ophthalmology, Putuo Hospital, Shanghai University of Chinese Traditional Medicine, No, 164, Lanxi Road, Shanghai (200062), China.
| | | | | | | | | | | | | |
Collapse
|
41
|
Heichel J, Wilhelm F, Kunert KS, Schlueter R, Stuhltraeger U, Hammer T. Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis. Clin Ophthalmol 2013; 8:61-9. [PMID: 24368878 PMCID: PMC3869919 DOI: 10.2147/opth.s51200] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose Femtosecond lasers have become the standard for laser-assisted in situ keratomileusis (LASIK) flap creation, but advanced mechanical microkeratomes are still an alternative, more cost-effective way to create the flap. The SCHWIND Carriazo-Pendular microkeratome is one of the most commonly used microkeratomes. The influence of different cutting parameters (head-advance speeds, cutting heads) on morphology of LASIK cuts was investigated. Setting Experimental study performed at the University Eye Hospital of the Martin Luther University Halle/Wittenberg, Halle (Saale), Germany. Methods The Carriazo-Pendular microkeratome was used on freshly enucleated porcine eyes for lamellar keratotomy. After flap removal, the cutting edge and stromal bed were evaluated from scanning electron micrographs using an individualized scoring system. Four different settings of microkeratome parameters were compared. For each setting, eight cuts were evaluated (n=32). Results Different oscillation frequencies and head-advance speeds did not influence the cutting qualities. A higher oscillation/feed rate ratio seemed to be advantageous for a smoother interface. Concerning different cuttings heads, a deeper keratotomy led to sharper cutting edges. The thinner the flap, the more irregularities in the stromal bed appeared. Complications did not occur. Conclusion The Carriazo-Pendular microkeratome is a safe tool with which to create a LASIK flap and is a good alternative to a costly femtosecond laser. Deeper keratotomies, as well as the use of a higher oscillation/feed rate quotient, improve the cutting quality.
Collapse
Affiliation(s)
- Jens Heichel
- Department of Ophthalmology, University Hospital of Martin Luther University Halle/Wittenberg, Halle (Saale), Germany
| | | | - Kathleen S Kunert
- Department of Ophthalmology, Helios Klinikum Erfurt, Erfurt, Germany
| | - Rabea Schlueter
- Institute of Microbiology, Ernst-Moritz-Arndt-University, Greifswald, Germany
| | - Ute Stuhltraeger
- Department of Ophthalmology, University Hospital of Martin Luther University Halle/Wittenberg, Halle (Saale), Germany
| | | |
Collapse
|
42
|
Kymionis GD, Kontadakis GA, Naoumidi I, Kankariya VP, Panagopoulou S, Manousaki A, Grentzelos MA, Pallikaris IG. Comparative study of stromal bed of LASIK flaps created with femtosecond lasers (IntraLase FS150, WaveLight FS200) and mechanical microkeratome. Br J Ophthalmol 2013; 98:133-7. [DOI: 10.1136/bjophthalmol-2013-304023] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
43
|
Kimakura M, Sakai O, Nakagawa S, Yoshida J, Shirakawa R, Toyono T, Yokoo S, Amano S. Stromal bed quality and endothelial damage after femtosecond laser cuts into the deep corneal stroma. Br J Ophthalmol 2013; 97:1404-9. [PMID: 24008824 DOI: 10.1136/bjophthalmol-2013-303328] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
AIM To evaluate the stromal bed quality and endothelial damage after femtosecond laser (FSL) cuts into the deep corneal stroma. METHODS Using a 150-kHz FSL, a lamellar cut was aimed at a depth of 100, 300, or 500 μm in porcine corneas. Stromal bed smoothness was graded from light microscopy and scanning electron microscopy images. Rabbit corneas were cut at remaining thicknesses of 70, 100 and 150 μm using the FSL. The effects of peeling off the corneal flap and the distance between laser spots (2 or 4 μm) were examined. RESULTS The ratio of damaged cells in the group with a remaining depth of 70 μm was significantly larger than that in the groups with a remaining depth of 150 μm. The ratio of damaged cells in the group with a 4-μm spot separation and the flap peeled off was significantly larger than that in the group with a 4-μm spot separation and the flap not peeled off. CONCLUSIONS Corneal endothelial damage is likely to increase when the remaining depth is less than 70 μm, and peeling off the flap damages corneal endothelial cells when the remaining depth is less than 100 μm.
Collapse
Affiliation(s)
- Mikiko Kimakura
- Department of Ophthalmology, University of Tokyo School of Medicine, , Tokyo, Japan
| | | | | | | | | | | | | | | |
Collapse
|
44
|
Wang Y, Li J, Liu Y, Xie L. Intraocular Straylight After Thin-Flap LASIK With a Femtosecond Laser Versus a Mechanical Microkeratome. J Refract Surg 2013; 29:534-9. [DOI: 10.3928/1081597x-20130719-03] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Accepted: 04/18/2013] [Indexed: 11/20/2022]
|
45
|
Posterior lamellar graft preparation: a prospective review from an eye bank on current and future aspects. J Ophthalmol 2013; 2013:769860. [PMID: 23819041 PMCID: PMC3683473 DOI: 10.1155/2013/769860] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2013] [Revised: 04/30/2013] [Accepted: 05/08/2013] [Indexed: 11/17/2022] Open
Abstract
Descemet membrane endothelial keratoplasty (DMEK) is a corneal surgical technique which selectively replaces the damaged posterior part of the cornea with a healthy donor graft retaining the rest of the tissue intact. There is a need to validate and standardize the donor tissue before grafting due to certain issues that can lead to consequences such as graft failure due to poor endothelial cell count, higher mortality, detachment of the graft, or increased surgical expenses, time, and effort. Thus, prospective potential surgeons and eye banks should now aim at developing new improved surgical techniques in order to prepare the best suited, validated, precut, preloaded, and easy to transplant tissue to reduce pre- and postsurgical complications. This could be achieved by defining parameters like graft thickness, accepted mortality threshold of the endothelial cells, and behavior of grafts during preservation and transportation along with using more sophisticated instruments like microkeratome and femtosecond lasers for graft preparation. Thus, a rapport between the eye banks and the surgeons along with the advanced instruments can overcome this challenge to find the best possible solution for endothelial keratoplasty (EK).
Collapse
|
46
|
Lee K, Ahn JM, Kim EK, Kim TI. Comparison of optical quality parameters and ocular aberrations after wavefront-guided laser in-situ keratomileusis versus wavefront-guided laser epithelial keratomileusis for myopia. Graefes Arch Clin Exp Ophthalmol 2013; 251:2163-9. [PMID: 23652467 DOI: 10.1007/s00417-013-2356-x] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2012] [Revised: 03/05/2013] [Accepted: 04/18/2013] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND To compare optical quality, ocular scattering, and higher-order aberrations (HOAs) after laser in-situ keratomileusis (LASIK) versus laser epithelial keratomileusis (LASEK). METHODS A total of 47 eyes from 47 participants who had undergone LASIK (group I) or LASEK (group II) procedure at least 6 months prior were enrolled. Ocular aberrations and modulation transfer function (MTF) values measured using iTrace, a ray-tracing type aberrometer, were compared to MTF (modulation transfer function) cut-off values, Strehl ratio, and objective indices of scattering obtained using the Objective Quality Analysis System II (OQAS II). RESULTS There was no significant correlation between the postoperative optical quality parameters and the HOAs between both groups. In group I, the MTF cut-off value was significantly correlated with cylinder refraction (p = 0.037), and the objective scattering index (OSI) was positively correlated with spherical equivalent (p = 0.023). In group II, there was a statistically significant correlation between the OSI and achieved refractive correction (p = 0.001). Regression analysis showed that the OSI was the most significant predictor of MTF cut-off values after refractive surgery. Additionally, MTF values measured by OQAS were significantly lower than those measured by iTrace without correlation. CONCLUSION Optical quality after refractive surgery may be influenced by not only ocular aberrations but also by scattering. Even though the accuracies of the machines used in this study to measure optical quality have yet to be proven, this study showed limited correlation among the values measured using the two different machines after refractive surgery. Therefore, for more generalized evaluation of visual function after refractive surgery, more advanced optical devices still need to be developed.
Collapse
Affiliation(s)
- Kwanghyun Lee
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-752, Republic of Korea
| | | | | | | |
Collapse
|
47
|
Gatinel D, Saad A, Guilbert E, Rouger H. Unilateral rainbow glare after uncomplicated femto-LASIK using the FS-200 femtosecond laser. J Refract Surg 2013; 29:498-501. [PMID: 23638845 DOI: 10.3928/1081597x-20130426-01] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2013] [Accepted: 03/26/2013] [Indexed: 11/20/2022]
Abstract
PURPOSE To report a case of rainbow glare following femtosecond laser-assisted LASIK (femto-LASIK) with the Wavelight FS-200 femtosecond laser (Alcon Laboratories, Inc., Fort Worth, TX). METHODS A patient was treated bilaterally for myopia with femto-LASIK using the FS-200 femtosecond laser. Postoperatively, he complained of rainbow glare in his right eye. RESULTS Three months postoperatively, the induced grating pattern (hyperreflective spot-like zones corresponding to the surgeon-programmed spot and line separation distance of the FS-200 femtosecond laser) was demonstrated with confocal microscopy at the level of the flap interface in the right eye. CONCLUSIONS This is the first report of rainbow glare following femto-LASIK with the FS-200 femtosecond laser documented with in vivo confocal microscopy.
Collapse
Affiliation(s)
- Damien Gatinel
- Department of Cataract and Refractive Surgery, Rothschild Foundation, Paris, France.
| | | | | | | |
Collapse
|
48
|
Abstract
PURPOSE OF REVIEW To review the literature for recent advancements in the femtosecond laser technology with regard to its applications in corneal transplantation and eye banking. RECENT FINDINGS Advancements in corneal surgery have encouraged the use of disease-specific corneal subcomponents, utilized in procedures such as anterior-lamellar keratoplasty and endothelial keratoplasty, instead of traditional transplant procedures to minimize adverse effects of penetrating keratoplasty. Femtosecond laser microkeratomes can precisely create flaps for such transplant procedures, achieve better wound stability, and promote healing by shaped wound configurations. Laser microkeratomes have been compared to traditional mechanical microkeratomes for keratoplasty procedures from various aspects and are superior in some aspects and offer unique capabilities. SUMMARY Femtosecond laser applications in eye banking include preparation of donor and recipient corneas for use in penetrating keratoplasty, anterior-lamellar keratoplasty, and endothelial keratoplasty. Advantages of femtosecond laser microkeratomes include higher precision of the cut, ability to achieve thinner flaps, and wound configurations that allow greater wound stability, shorter recovery time, and less postoperative pain. However, cost and availability at the eye-bank level may hinder widespread and immediate application.
Collapse
|
49
|
Arenas E, Esquenazi S, Anwar M, Terry M. Lamellar corneal transplantation. Surv Ophthalmol 2013; 57:510-29. [PMID: 23068974 DOI: 10.1016/j.survophthal.2012.01.009] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2011] [Revised: 01/24/2012] [Accepted: 01/27/2012] [Indexed: 11/29/2022]
Abstract
Penetrating keratoplasty (PK) has been the gold standard for the surgical treatment of most corneal pathologies; lamellar keratoplasty that only replaces the diseased corneal layers has recently evolved as an alternative, however. Innovations in surgical technique and instrumentation provide visual outcomes comparable to PK. We review the indications and outcomes of various techniques of anterior lamellar surgery developed to treat stromal disorders. Similarly, we discuss posterior lamellar keratoplasty techniques such as Descemet stripping automated endothelial keratoplasty and Descemet membrane endothelial keratoplasty. Posterior lamellar keratoplasty provides faster visual rehabilitation than PK in cases of Fuchs endothelial dystrophy and pseudophakic bullous keratopathy. In addition, for medically unresponsive infectious keratitis, therapeutic anterior lamellar keratoplasty yields similar graft survival to PK without an increased risk of disease recurrence.
Collapse
|
50
|
Irregularity of the Posterior Corneal Surface After Curved Interface Femtosecond Laser-Assisted Versus Microkeratome-Assisted Descemet Stripping Automated Endothelial Keratoplasty. Cornea 2013; 32:118-24. [PMID: 23132446 DOI: 10.1097/ico.0b013e31826ae2d8] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|