1
|
Maguire MJ, Munro DJ, Merz P, Laidlaw A, Auffarth GU. Intraocular lens calcification in a patient with Ehlers-Danlos syndrome. Am J Ophthalmol Case Rep 2024; 35:102080. [PMID: 38827999 PMCID: PMC11143781 DOI: 10.1016/j.ajoc.2024.102080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 03/12/2024] [Accepted: 05/03/2024] [Indexed: 06/05/2024] Open
Abstract
Introduction Calcification of hydrophilic intraocular lenses (IOL) is a rare complication following cataract surgery. Secondary calcification is described as due to host factors or changes in the IOL environment and uveitis, proliferative diabetic retinopathy and sequelae of ocular surgery are recognised potentiators. The impact of systemic connective tissue disease on IOL opacification is yet to described. Purpose To describe the clinical presentation and management of a young patient, with a rare subtype of Ehlers-Danlos syndrome, who presented with secondary IOL calcification 14 years after primary IOL insertion. Observations Floret-like lesions were observed on the IOL surface. Positive staining for calcification was observed with Alizarin red and von Kossa method on laboratory analysis. Conclusions and importance Patients with systemic connective tissue disease, such as a subtype of Ehlers-Danlos, may present with secondary IOL calcification many years after primary lens insertion. This poses an additional consideration when implanting IOLs in these patients.Good visual acuity can be achieved with IOL exchange.
Collapse
|
2
|
Friedrich M, Son HS, Hassel O, Teich L, Augustin VA, Khoramnia R, Auffarth GU, Yildirim TM. Early intraocular lens explantations: 10-year database analysis. BMC Ophthalmol 2024; 24:300. [PMID: 39039537 PMCID: PMC11265132 DOI: 10.1186/s12886-024-03570-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Accepted: 07/11/2024] [Indexed: 07/24/2024] Open
Abstract
BACKGROUND The aim of this study was to analyze the causes and characteristics of IOL explantation within the first year after primary implantation. METHODS In this retrospective, cross sectional database study, a database consisting of over 2500 IOL explants sent from 199 national and international doctors over the past 10 years was analyzed. All IOLs explanted within the first year after implantation were included in this analysis. Explants with insufficient information as well as phakic and Add-on IOLs were excluded. Main outcome measures were the reason for explantation, the time between implantation and explantation, as well as IOLs' and patients' characteristics. Additionally, the explanted IOLs were microscopically and histologically analyzed, as required. RESULTS Of all explanted IOLs from the database, 1.9% (n = 50) were explanted within the first year after implantation. The most frequent reasons for early IOL explantation were IOL dislocation (32%), visual intolerance (26%), opacification (20%), and intraoperative complications (16%). The time between implantation and explantation was the shortest in cases with intraoperative complications (1.5 ± 3.1 days), followed by IOL dislocation (90.9 ± 103.9 days), visual intolerance (98.3 ± 86.5 days), opacifications (253.5 ± 124.0 days) and other indications (249.7 ± 124.0 days). Calcification of hydrophilic IOLs was the main type of opacification (80%). Notably, seven IOLs required immediate intraoperative exchange due to an intraoperative crack in the optic or a torn off haptic. CONCLUSION Indications for early IOL explantation were IOL dislocation, visual intolerance, opacification, and intraoperative complications. Especially intraoperative damages to the IOL and early calcification show a potential for improvement of affected IOLs and implantation systems.
Collapse
Affiliation(s)
- Maximilian Friedrich
- Department of Ophthalmology, The David J Apple Center for Vision Research, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Hyeck-Soo Son
- Department of Ophthalmology, The David J Apple Center for Vision Research, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Oliver Hassel
- Department of Ophthalmology, The David J Apple Center for Vision Research, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Lilly Teich
- Department of Ophthalmology, The David J Apple Center for Vision Research, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Victor Aristide Augustin
- Department of Ophthalmology, The David J Apple Center for Vision Research, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Ramin Khoramnia
- Department of Ophthalmology, The David J Apple Center for Vision Research, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Gerd Uwe Auffarth
- Department of Ophthalmology, The David J Apple Center for Vision Research, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Timur Mert Yildirim
- Department of Ophthalmology, The David J Apple Center for Vision Research, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| |
Collapse
|
3
|
Khoramnia R, Naujokaitis T, Łabuz G, Auffarth GU. Are There Patient-Relevant Differences in the Material Properties of Intraocular Lenses? Klin Monbl Augenheilkd 2024; 241:602-604. [PMID: 38776928 DOI: 10.1055/a-2261-1107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2024]
Affiliation(s)
- Ramin Khoramnia
- Augenklinik, Universitätsklinikum Heidelberg/Department of Ophthalmology, University Hospital of Heidelberg
| | - Tadas Naujokaitis
- Augenklinik, Universitätsklinikum Heidelberg/Department of Ophthalmology, University Hospital of Heidelberg
| | - Grzegorz Łabuz
- Augenklinik, Universitätsklinikum Heidelberg/Department of Ophthalmology, University Hospital of Heidelberg
| | - Gerd U Auffarth
- Augenklinik, Universitätsklinikum Heidelberg/Department of Ophthalmology, University Hospital of Heidelberg
| |
Collapse
|
4
|
Baur ID, Łabuz G, Chychko L, Yildirim TM, Naujokaitis T, Auffarth GU, Khoramnia R. In vivo comparison of implantation behavior and laboratory analysis of two preloaded intraocular lens injectors. Eur J Ophthalmol 2024; 34:766-773. [PMID: 37750504 PMCID: PMC11082425 DOI: 10.1177/11206721231204382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 09/13/2023] [Indexed: 09/27/2023]
Abstract
PURPOSE We evaluated implantation behavior and injector damage of two different IOL injector systems, the Multisert and the AutonoMe. DESIGN Prospective, randomized, comparative study with laboratory investigation. METHODS We examined used injectors from 48 bilateral cataract cases and assessed video recordings of each Implantation. All eyes were intraindividually randomized for treatment with one of the two IOL injectors. Implantation videos were reviewed for inadvertent events and the time for different implantation steps was determined. The injector nozzle tips were examined using light and scanning electron microscopy (SEM). Damage was graded using the Heidelberg Score for IOL injector damage (HeiScore). Three months postoperatively, IOLs were assessed for material changes. RESULTS Implantation was without critical events in 96 of 96 eyes. Mean implantation time was 41.90 ± 7.11 s with the Multisert and 52.22 ± 12.06 s with the AutonoMe. In the AutonoMe group, we observed 4 eyes (8.3%) with a failed docking attempt, 28 eyes (58.3%) with a haptic adherence, one case (2.1%) of straight leading haptic and 2 cases (4.2%) of intrawound IOL manipulation. There were no events observed in the Multisert group. The mean HeiScore values were 0.87 ± 0.61 and 3.68 ± 0.47 for the AutonoMe and Multisert. 3 months postoperatively, IOL material changes were absent. CONCLUSIONS Both injectors allowed safe and controlled implantation. Using Multisert, implantation behavior was more consistent. The injectors showed different damage profiles with a higher damage score for the Multisert.The study is registered at the German Clinical Trials Register (Deutsches Register Klinischer Studien; reference number: DRKS00007837).
Collapse
Affiliation(s)
- Isabella D Baur
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Grzegorz Łabuz
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Lizaveta Chychko
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Timur M Yildirim
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Tadas Naujokaitis
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Gerd U Auffarth
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Ramin Khoramnia
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
5
|
Renschler A, Kelkar N, Eid K, Hawn V, Bundogji N, Werner L, Mamalis N. Complications of foldable intraocular lenses requiring explantation or secondary intervention: 2022 survey with update of long-term trends. J Cataract Refract Surg 2024; 50:394-400. [PMID: 37994083 DOI: 10.1097/j.jcrs.0000000000001371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 11/13/2023] [Indexed: 11/24/2023]
Abstract
PURPOSE To assess the complications that resulted in the explantation or secondary intervention with foldable intraocular lenses (IOLs). SETTING University setting, Salt Lake City, Utah. DESIGN Survey study. METHODS For the 25th consecutive year, surgeons were surveyed regarding complications associated with foldable IOLs requiring explantation or secondary intervention over the 2022 calendar year. These forms were made available online using the ASCRS and ESCRS websites and a fax-on-demand service. Surgeons completed 1 survey for each foldable IOL requiring explantation or secondary intervention. Further analysis determined complication trends related to specific IOL styles, materials, and types over the past 16 years (2007 to 2022). RESULTS 103 completed surveys were returned in 2022 contributing to a total of 1627 tabulated surveys since 2007. In the 2022 survey, dislocation/decentration continued to be the most common complication overall. Glare/optical aberrations was a common complication associated with multifocal IOLs continuing a 16-year trend. In addition, hydrophilic acrylic IOLs as well as some silicone lenses in eyes with asteroid hyalosis demonstrated calcification as the most common complication necessitating explantation. CONCLUSIONS Dislocation/decentration remains the leading cause of explantation in most IOL types. Glare/optical aberrations continue to be an associated complication of multifocal IOLs suggesting this ongoing issue has yet to be resolved with this type of IOL. In addition, calcification of hydrophilic acrylic lenses and silicone lenses is a rare event but continues to occur.
Collapse
Affiliation(s)
- Andy Renschler
- From the University of Utah School of Medicine, Salt Lake City, Utah (Renschler, Kelkar, Eid, Hawn, Bundogji, Werner, Mamalis); Intermountain Ocular Research Center, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah (Kelkar, Eid, Hawn, Bundogji, Werner, Mamalis)
| | | | | | | | | | | | | |
Collapse
|
6
|
Fernández-Vigo JI, Macarro-Merino A, De Moura-Ramos JJ, Alvarez-Rodriguez L, Burgos-Blasco B, Novo-Bujan J, Ortega-Hortas M, Fernández-Vigo JÁ. Comparative study of the glistening between four intraocular lens models assessed by OCT and deep learning. J Cataract Refract Surg 2024; 50:37-42. [PMID: 37702457 DOI: 10.1097/j.jcrs.0000000000001316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 09/08/2023] [Indexed: 09/14/2023]
Abstract
PURPOSE To evaluate the glistening in 4 different models of intraocular lenses (IOLs) using optical coherence tomography (OCT) and deep learning (DL). SETTING Centro Internacional de Oftalmología Avanzada (Madrid, Spain). DESIGN Cross-sectional study. METHODS 325 eyes were assessed for the presence and severity of glistening in 4 IOL models: ReSTOR+3 SN6AD1 (n = 41), SN60WF (n = 110), PanOptix TFNT (n = 128) and Vivity DFT015 (n = 46). The presence of glistening was analyzed using OCT, identifying the presence of hyperreflective foci (HRF) in the central area of the IOL. A manual and an original DL-based quantification algorithm designed for this purpose was applied. RESULTS Glistening was detected in 22 (53.7%) ReSTOR SN6AD1, 44 (40%) SN60WF, 49 (38.3%) PanOptix TFNT, and 4 (8.7%) Vivity DFT015 IOLs, when any grade was considered. In the comparison of the different types of IOLs, global glistening measured as total HRF was 17.3 ± 25.9 for the ReSTOR+3; 9.3 ± 15.7 for the SN60WF; 6.9 ± 10.5 for the PanOptix; and 1.2 ± 2.6 for the Vivity ( P < .05). There was excellent agreement between manual and DL-based quantification (≥0.829). CONCLUSIONS It is possible to quantify, classify and compare the glistening severity in different IOL models using OCT images in a simple and objective manner with a DL algorithm. In the comparative study, the Vivity presented the lowest severity of glistening.
Collapse
Affiliation(s)
- José Ignacio Fernández-Vigo
- From the Centro Internacional de Oftalmología Avanzada, Madrid, Spain (J.I. Fernández-Vigo, Macarro-Merino, J.Á. Fernández-Vigo); Department of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain (J.I. Fernández-Vigo, Burgos-Blasco); Department of Computational, Centro de Investigacion CITIC, Universidade da Coruña, A Coruña, Spain (De Moura-Ramos, Alvarez-Rodriguez, Novo-Bujan, Ortega-Hortas); Department of Computational, VARPA Research Group, Instituto de Investigación Biomédica de A Coruña (INIBIC), Universidade da Coruña, A Coruña, Spain (De Moura-Ramos, Alvarez-Rodriguez, Novo-Bujan, Ortega-Hortas); Department of Ophthalmology, Universidad de Extremadura, Badajoz, Spain (J.Á. Fernández-Vigo)
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Britz L, Schickhardt SK, Yildirim TM, Auffarth GU, Lieberwirth I, Khoramnia R. [Hydrophobic surface properties of hydrophilic acrylic lenses do not protect against calcification]. DIE OPHTHALMOLOGIE 2023; 120:1022-1028. [PMID: 37171476 DOI: 10.1007/s00347-023-01862-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 02/21/2023] [Accepted: 04/06/2023] [Indexed: 05/13/2023]
Abstract
BACKGROUND Opacification through calcification of hydrophilic acrylic intraocular lenses is a serious complication of cataract surgery, which usually results in explantation of the lens. In the process of calcification, the intraocular lens material plays a crucial role: calcification only occurs in hydrophilic acrylic lenses. Hydrophobic acrylic lenses show no crystal formation within the polymer. Hydrophilic acrylic lenses from some manufacturers have hydrophobic surface properties. The question arises as to what influence these surface properties have on the risk of calcification. OBJECTIVE The present study investigated whether the hydrophobic surface properties of hydrophilic acrylic lenses can prevent calcification. MATERIAL AND METHODS Using an electrophoretic in vitro model of calcification, two hydrophilic lenses with hydrophobic surface properties were compared to two hydrophilic lenses and a hydrophobic negative control to determine the risk of calcification. The lenses were then analyzed by optical microscopy, Alizarin Red and Von Kossa staining, scanning electron microscopy (SEM) and energy dispersive X‑ray spectroscopy (EDX). RESULTS All four hydrophilic lens models showed calcification within the polymer. No difference was found between the hydrophilic lenses and the hydrophilic lenses with hydrophobic surface properties in terms of crystal formation. The hydrophobic negative control showed no calcification. CONCLUSION The investigation conducted in this study under standardized conditions could show that hydrophobic surface properties of hydrophilic acrylic lenses do not protect against calcium phosphate crystal formation within the polymer. There also is a risk of calcification in these lens models.
Collapse
Affiliation(s)
- Leoni Britz
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Sonja Katrin Schickhardt
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Timur Mert Yildirim
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Gerd Uwe Auffarth
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Ingo Lieberwirth
- Department of Physical Chemistry of Polymers, Max Planck Institute for Polymer Research, Mainz, Deutschland
| | - Ramin Khoramnia
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland.
| |
Collapse
|
8
|
Tuuminen R, Knyazer B, Kanclerz P. Comment on: Cataract surgery in patients with retinitis pigmentosa: systematic review. J Cataract Refract Surg 2023; 49:999-1000. [PMID: 37379023 DOI: 10.1097/j.jcrs.0000000000001247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023]
Affiliation(s)
- Raimo Tuuminen
- From the Helsinki Retina Research Group, Faculty of Medicine, University of Helsinki, Helsinki, Finland (Tuuminen); Eye Centre, Kymenlaakso Central Hospital, Kotka, Finland (Tuuminen); Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel (Knyazer); Department of Ophthalmology, Soroka University Medical Center, Beer-Sheva, Israel (Knyazer); Hygeia Clinic, Gdańsk, Poland (Kanclerz)
| | | | | |
Collapse
|
9
|
Fernández-Vigo JI, Serrano González-Peramato MT, Nunila Gómez-de-Liaño C, Sánchez-Guillén I, Fernández-Vigo JÁ, Macarro-Merino A. Glistening on intraocular lenses: A review. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023; 98:493-506. [PMID: 37369324 DOI: 10.1016/j.oftale.2023.06.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023]
Abstract
The glistening in intraocular lenses (IOLs) is a phenomenon in which tiny water-filled microvacuoles (MVs) form within the IOL material, causing light to scatter and create a sparkling or shimmering effect. The presence of glistening is common in many types of IOL materials and models and has been extensively studied in recent years to determine its incidence, risk factors, evolution, and possible clinical relevance. Classically, it has been studied in vitro in the laboratory or by means of photography obtained with a slit lamp, but these were techniques that required either specific technology or an expert explorer, complex image processing, and required a lot of time. In recent years, proposals based on the Scheimpflug camera and optical coherence tomography have emerged to try to simplify the analysis of glistening in IOLs. It has been described that the manufacturing process, the hydrophobic acrylic material, or the time since surgery are risk factors for the appearance of glistening. In addition, many issues related to this phenomenon are still unknown, such as not knowing from what number of points or their size they may have relevance to visual function since different optical phenomena related to glistening have been described on the IOLs.
Collapse
Affiliation(s)
- J I Fernández-Vigo
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Madrid, Spain.
| | | | - C Nunila Gómez-de-Liaño
- Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain
| | - I Sánchez-Guillén
- Servicio de Oftalmología, Hospital Perpetuo Socorro, Badajoz, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain
| | - J Á Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain; Departamento de Oftalmología, Facultad de Medicina, Universidad de Extremadura, Badajoz, Spain
| | - A Macarro-Merino
- Centro Internacional de Oftalmología Avanzada, Madrid, Spain; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain
| |
Collapse
|
10
|
Britz L, Schickhardt SK, Auffarth GU, Khoramnia R. Opacification of Hydrophilic Acrylic Intraocular Lenses: Overview of Laboratory Methods for Histological Analysis and Replication of IOL Calcification. Klin Monbl Augenheilkd 2023; 240:960-970. [PMID: 37391183 DOI: 10.1055/a-2073-8526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/02/2023]
Abstract
Opacification of intraocular lenses (IOLs) due to material changes is a serious complication that can compromise the good visual outcomes of uncomplicated cataract surgery. In hydrophobic acrylic IOLs, opacification can result from glistening formation, while in hydrophilic acrylic IOLs, there is a risk of calcification due to the formation of calcium phosphates within the polymer. Over time, various methods have been developed to investigate calcification in hydrophilic acrylic IOLs. The aim of this article is to provide an overview of standard histological staining and models used to simulate IOL calcification. Histological staining can be used to detect calcification and assess the extent of crystal formation. The development of in vivo and in vitro replication models has helped to identify the underlying pathomechanisms of calcification. In vivo models are suitable for assessing the biocompatibility of IOL materials. Bioreactors as an in vitro model can be used to investigate the kinetics of crystal formation within the polymer. The replication of IOL calcification under standardized conditions using electrophoresis allows for the comparison of different lens materials with respect to the risk of calcification. The combination of different analytical and replication methods can be used in the future to further investigate the pathomechanisms of calcium phosphate crystal formation and the influence of risk factors. This may help to prevent calcification of hydrophilic acrylic IOLs and associated explantation and complications.
Collapse
Affiliation(s)
- Leoni Britz
- Universitäts-Augenklinik, UniversitätsKlinikum Heidelberg, Deutschland
| | | | - Gerd U Auffarth
- Universitäts-Augenklinik, UniversitätsKlinikum Heidelberg, Deutschland
| | - Ramin Khoramnia
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Univ.-Augenklinik Heidelberg, Deutschland
| |
Collapse
|
11
|
Xie J, Zang X, Mao S, Sun J, Liu T, Dai Y. Late postoperative opacification of a new type hydrophilic acrylic intraocular lens. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH 2023; 3:134-140. [PMID: 37846363 PMCID: PMC10577844 DOI: 10.1016/j.aopr.2023.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 06/16/2023] [Accepted: 06/19/2023] [Indexed: 10/18/2023]
Abstract
Background To report the clinical consequences and laboratory characteristics of late postoperative opacification of a hydrophilic acrylic intraocular lens (US-860UV IOL) as well as the prognosis of IOL replacement. Methods Forty medical records (42 eyes) of patients with US-860UV IOL opacification reporting decreased or lost vision who underwent IOL explantation between 2017 and 2019 were reviewed. Explanted IOLs were analyzed by slit-lamp examination, confocal microscopy, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) at the Shandong Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University, and Qingdao University of Science and Technology, Qingdao, China. Results The mean age of the 40 patients was 74.83 ± 7.57 (63-92) years. The mean interval between cataract surgery and diagnosis of opacification was 32.38 ± 8.76 (17-48) months. Systemic diseases were found without statistical correlations, the most frequent being arterial hypertension, coronary heart disease, and diabetes mellitus. Visual acuity improved from 1.42 ± 1.03 to 0.31 ± 0.16 (logMAR) after IOL replacement. SEM, EDS and alizarin red staining showed uniformly distributed, diffuse, milk-white opacification, with calcium and phosphorus deposits on the optic and haptic surfaces that could be dissolved in 1% HCl. Conclusions Calcium and phosphorus deposition was the main cause of hydrophilic acrylic US-860UV IOL opacification. IOL replacement can safely and effectively improve the visual acuity of patients.
Collapse
Affiliation(s)
- Jin Xie
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, China
| | - Xinyi Zang
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China
- Weifang Medical University, Weifang, Shandong, China
| | - Shilan Mao
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, China
- Shandong First Medical University, Jinan, Shandong, China
| | - Jie Sun
- People's Hospital of Yinan, Linyi, Shandong, China
| | - Ting Liu
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, China
| | - Yunhai Dai
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, China
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, China
| |
Collapse
|
12
|
Fernández-Vigo JI, Burgos-Blasco B, De-Pablo-Gómez-de-Liaño L, Sánchez-Guillén I, Albitre-Barca V, Fernández-Aragón S, Fernández-Vigo JÁ, Macarro-Merino A. Reply to Stanojcic et al. Comment on "Fernández-Vigo et al. Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System. J. Clin. Med. 2023, 12, 2351". J Clin Med 2023; 12:jcm12113686. [PMID: 37297882 DOI: 10.3390/jcm12113686] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 05/19/2023] [Accepted: 05/22/2023] [Indexed: 06/12/2023] Open
Abstract
We appreciate the comments made by Stanojcic et al. [...].
Collapse
Affiliation(s)
- José Ignacio Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, 28010 Madrid, Spain
- Department of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), 28040 Madrid, Spain
| | - Bárbara Burgos-Blasco
- Department of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), 28040 Madrid, Spain
| | - Lucía De-Pablo-Gómez-de-Liaño
- Centro Internacional de Oftalmología Avanzada, 28010 Madrid, Spain
- Department of Ophthalmology, Hospital Universitario 12 de Octubre, 28041 Madrid, Spain
| | - Inés Sánchez-Guillén
- Department of Ophthalmology, Hospital Perpetuo Socorro, 06010 Badajoz, Spain
- Centro Internacional de Oftalmología Avanzada, 06011 Badajoz, Spain
| | | | | | - José Ángel Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, 28010 Madrid, Spain
- Centro Internacional de Oftalmología Avanzada, 06011 Badajoz, Spain
- Department of Ophthalmology, Universidad de Extremadura, 06006 Badajoz, Spain
| | - Ana Macarro-Merino
- Centro Internacional de Oftalmología Avanzada, 28010 Madrid, Spain
- Centro Internacional de Oftalmología Avanzada, 06011 Badajoz, Spain
| |
Collapse
|
13
|
Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System. J Clin Med 2023; 12:jcm12062351. [PMID: 36983351 PMCID: PMC10057385 DOI: 10.3390/jcm12062351] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/10/2023] [Accepted: 03/15/2023] [Indexed: 03/22/2023] Open
Abstract
Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; p < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.
Collapse
|
14
|
Ní Dhubhghaill S, Janssen C, Dragnea DC, Van Os L, Rozema J, Werner L, Van Dyck D, Tassignon MJ. Wave-like calcification on the posterior surface of an acrylic hydrophilic bag-in-the-lens (BIL) implant. Am J Ophthalmol Case Rep 2022; 28:101693. [PMID: 36090304 PMCID: PMC9449740 DOI: 10.1016/j.ajoc.2022.101693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 07/25/2022] [Accepted: 08/22/2022] [Indexed: 11/19/2022] Open
Abstract
Purpose To report secondary opacification of a hydrophilic bag-in-the-lens (BIL) which is a rare manifestation that can happen years after initial surgery. Observations We describe a case of a prominent wave-like, rippled opacification on the posterior surface of the BIL. The opacification was composed of calcium deposits and seems to start in the periphery as a ring and progresses to the centre of the posterior surface. Due to the specific design of the BIL, there is direct contact between the BIL and the posterior chamber, both with the space of Berger, and the anterior hyaloid, particularly in this very hyperopic eye. Conclusions and importance: Abnormal fluid flow and stagnation in an unusual retrolenticular space is a possible explanation for this unusual pattern of posterior surface opacification.
Collapse
Affiliation(s)
- Sorcha Ní Dhubhghaill
- Antwerp University Hospital, Edegem, Belgium
- Faculty of Health Sciences, University of Antwerp, Belgium
- Corresponding author. Antwerp University Hospital, Edegem, Belgium.
| | | | | | - Luc Van Os
- Antwerp University Hospital, Edegem, Belgium
- Faculty of Health Sciences, University of Antwerp, Belgium
| | - Jos Rozema
- Antwerp University Hospital, Edegem, Belgium
- Faculty of Health Sciences, University of Antwerp, Belgium
| | - Liliana Werner
- John A. Moran Eye Center, University of Utah, Salt Lake City, UT, United States
| | - Dirk Van Dyck
- Faculty of Physics, Antwerp University, Wilrijk, Belgium
| | - Marie-José Tassignon
- Antwerp University Hospital, Edegem, Belgium
- Faculty of Health Sciences, University of Antwerp, Belgium
| |
Collapse
|
15
|
Hecht I, Kanclerz P, Tuuminen R. Secondary outcomes of lens and cataract surgery: More than just “best-corrected visual acuity”. Prog Retin Eye Res 2022:101150. [DOI: 10.1016/j.preteyeres.2022.101150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 11/07/2022] [Accepted: 11/20/2022] [Indexed: 12/12/2022]
|
16
|
Specifying Risk of Intraocular Lens Opacification After Endothelial Keratoplasty for Different Intraocular Lens Models: A Retrospective Monocentric Cohort Study. Cornea 2022:00003226-990000000-00119. [PMID: 36633939 DOI: 10.1097/ico.0000000000003087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 05/18/2022] [Indexed: 01/13/2023]
Abstract
PURPOSE The aims of this study were to calculate the specific risk of opacification for different intraocular lens (IOL) models and to determine whether differences exist, even between lenses made of similar acrylic materials. METHODS This is a retrospective cohort study of all patients who underwent endothelial keratoplasty (EK), either after or in conjunction with cataract surgery, from June 2009 to October 2020 at Fundación Jiménez Díaz Hospital. RESULTS Three hundred seventy-two eyes of 308 patients with a median follow-up of 856 days [interquartile range (IQR): 384-1570] were included, of which 128 IOLs were hydrophobic, 120 hydrophilic, and 124 unknown. 12.9% of IOLs opacified after a median of 466 days (IQR: 255-743). Visual acuity (VA) was significantly lower in the opacified IOL group [0.51 (IQR: 0.36-1.13)] compared with the nonopacified group [0.22 (IQR: 0.11-0.65)] ( P < 0.001). IOL explantation and exchange was performed in 10 eyes, in which VA improved markedly, from 1.75 (IQR: 0.99-3.00) to 0.60 (IQR: 0.36-0.86) ( P = 0.004). IOL material and opacification events were not independent ( P < 0.001). Significant differences were found between the Akreos ADAPT AO and MI60P models and the Asphina 409M model ( P = 0.022). No significant differences were found in the opacification ratio for hydrophilic IOLs in the clinical diagnosis ( P = 0.11), the type of EK ( P = 0.25), the rebubbling rate ( P = 0.44), or the tamponade used ( P = 0.36). CONCLUSIONS Hydrophilic lenses should be avoided in patients at risk of requiring EK. It is important to know the probability of opacification of each IOL model to balance risk and benefits when planning an EK procedure because not all lenses opacify equally. Opacification is an unwanted event with a negative impact on VA, making IOL explantation and exchange the only viable treatment, although one that is not without risks.
Collapse
|
17
|
Kanclerz P, Tuuminen R. Advancements in Postoperative Care after Cataract Surgery. J Clin Med 2022; 11:jcm11113162. [PMID: 35683549 PMCID: PMC9181706 DOI: 10.3390/jcm11113162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Accepted: 05/29/2022] [Indexed: 11/16/2022] Open
Abstract
Cataract surgery is one of the most frequently performed surgical procedures in many countries [...].
Collapse
Affiliation(s)
- Piotr Kanclerz
- Helsinki Retina Research Group, Faculty of Medicine, University of Helsinki, 00014 Helsinki, Finland
- Hygeia Clinic, 80-286 Gdańsk, Poland
- Correspondence: (P.K.); (R.T.); Tel.: +48-58-776-40-46 (P.K.); +358-50-411-3870 (R.T.); Fax: +48-58-776-40-46 (P.K.); +358-9-2411-227 (R.T.)
| | - Raimo Tuuminen
- Helsinki Retina Research Group, Faculty of Medicine, University of Helsinki, 00014 Helsinki, Finland
- Department of Ophthalmology, Kymenlaakso Central Hospital, 48210 Kotka, Finland
- Correspondence: (P.K.); (R.T.); Tel.: +48-58-776-40-46 (P.K.); +358-50-411-3870 (R.T.); Fax: +48-58-776-40-46 (P.K.); +358-9-2411-227 (R.T.)
| |
Collapse
|
18
|
Xie J, Sun J, Liu T, Mao S, Dai Y. Comparison Between L-312 Hydrophobic-Hydrophilic Acrylate and US-860 UV Hydrophilic Acrylate IOL Opacification Characteristic. Front Med (Lausanne) 2022; 9:873684. [PMID: 35463016 PMCID: PMC9024102 DOI: 10.3389/fmed.2022.873684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 03/11/2022] [Indexed: 11/20/2022] Open
Abstract
Objective To compare opacity characteristics of US-860 UV and L-312 IOL, and report the phenomenon of glistenings in hydrophobic-hydrophilic acrylic IOLs. Setting Qingdao Eye Hospital. Design Experimental study. Methods Four medical records (4 eyes) of patients with L-312 or US-860 UV IOL opacification reporting decreased or lost vision who underwent IOL explanation between 2019 and 2021 were reviewed. Explanted IOLs were analyzed by slit-lamp examination, confocal microscopy, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) at Qingdao Eye Hospital and Qingdao university of science and technology. Results The 4 explanted IOLs were represented by 2 hydrophilic acrylic designs. The preoperative mean corrected distance visual acuity changed from 1.84 ± 1.09 logarithm of the minimum angle of resolution (log MAR) to 0.20 ± 0.03 log MAR postoperatively except case 3. The mean interval of the L-312 IOL was 56.67 ± 14.19 months (range 44 to 72 months), and the interval of the US-860 UV IOL was 27 months. Morphological findings were surface, subsurface calcifications of the US-860 UV IOL material, and the optical region of L-312 IOLs are teeming with a great number of vacuoles by light microscope, scanning electron microscope and Energy Dispersive X-ray Spectral. Conclusion The cause of US-860 UV opacification was primary calcification, and vacuoles resulted in L-312 IOL opacification.
Collapse
Affiliation(s)
- Jin Xie
- Department of Ophthalmology, Graduate College of Shandong First Medical University, Jinan, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Jie Sun
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- People's Hospital of Yinan, Linyi, China
| | - Ting Liu
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Shilan Mao
- Department of Ophthalmology, Graduate College of Shandong First Medical University, Jinan, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Yunhai Dai
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, China
- Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- *Correspondence: Yunhai Dai
| |
Collapse
|
19
|
Posterior Capsule Opacification after Cataract Surgery via Implantation with Hydrophobic Acrylic Lens Compared with Silicone Intraocular Lens: A Systematic Review and Meta-Analysis. J Ophthalmol 2022; 2022:3570399. [PMID: 35251708 PMCID: PMC8896947 DOI: 10.1155/2022/3570399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 01/26/2022] [Indexed: 11/18/2022] Open
Abstract
Hydrophobic acrylic intraocular lens (IOL) is the most popular material in cataract surgery. Posterior capsule opacification (PCO) is a long-term complication of cataract surgery. It can impair vision and adversely affect the prognosis of IOL delamination. The objective of this study was to perform a systematic review and meta-analysis to provide an updated evaluation of long-term complications and visual function after implantation with hydrophobic acrylic and silicone intraocular lenses. PubMed, Embase, and Cochrane Library were searched from January 2000 until March 2021. Randomized controlled trials (RCTs) and retrospective studies were finally included. The main outcomes were PCO value and neodymium-doped yttrium aluminum garnet (Nd : YAG) capsulotomy rate. Subgroup analysis was performed to compare hydrophobic acrylic and silicone IOLs during the follow-up period. Sensitivity analysis was also performed. The meta-analysis included a total of 17 studies. When the follow-up period was considered, the results of the analysis revealed higher PCO value (Group 3: standardized mean difference (SMD), −0.59; 95% confidence interval (CI), −0.90 to −0.28) and Nd : YAG capsulotomy rate (Group 3: risk ratio (RR), 0.60; 95% CI, 0.40–0.89) for hydrophobic acrylic IOLs than silicone IOLs during a long-term (≥6 years) follow-up. In conclusion, both the PCO value and the Nd : YAG capsulotomy rates were higher in hydrophobic acrylic IOLs group than the silicone IOLs group at long-term use (more than 6 years) after implantation.
Collapse
|
20
|
Lanza M, Koprowski R, Boccia R, Ruggiero A, De Rosa L, Tortori A, Wilczyński S, Melillo P, Sbordone S, Simonelli F. Classification Tree to Analyze Factors Connected with Post Operative Complications of Cataract Surgery in a Teaching Hospital. J Clin Med 2021; 10:jcm10225399. [PMID: 34830681 PMCID: PMC8625404 DOI: 10.3390/jcm10225399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 11/18/2021] [Accepted: 11/18/2021] [Indexed: 11/16/2022] Open
Abstract
Background: Artificial intelligence (AI) is becoming ever more frequently applied in medicine and, consequently, also in ophthalmology to improve both the quality of work for physicians and the quality of care for patients. The aim of this study is to use AI, in particular classification tree, for the evaluation of both ocular and systemic features involved in the onset of complications due to cataract surgery in a teaching hospital. Methods: The charts of 1392 eyes of 1392 patients, with a mean age of 71.3 ± 8.2 years old, were reviewed to collect the ocular and systemic data before, during and after cataract surgery, including post-operative complications. All these data were processed by a classification tree algorithm, producing more than 260 million simulations, aiming to develop a predictive model. Results: Postoperative complications were observed in 168 patients. According to the AI analysis, the pre-operative characteristics involved in the insurgence of complications were: ocular comorbidities, lower visual acuity, higher astigmatism and intra-operative complications. Conclusions: Artificial intelligence application may be an interesting tool in the physician’s hands to develop customized algorithms that can, in advance, define the post-operative complication risk. This may help in improving both the quality and the outcomes of the surgery as well as in preventing patient dissatisfaction.
Collapse
Affiliation(s)
- Michele Lanza
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy; (R.B.); (A.R.); (L.D.R.); (A.T.); (P.M.); (S.S.); (F.S.)
- Correspondence: ; Tel.: +39-08-1566-6778
| | - Robert Koprowski
- Institute of Biomedical Engineering, Faculty of Science and Technology, University of Silesia in Katowice, Bedzińska 39, 41-200 Sosnowiec, Poland;
| | - Rosa Boccia
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy; (R.B.); (A.R.); (L.D.R.); (A.T.); (P.M.); (S.S.); (F.S.)
| | - Adriano Ruggiero
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy; (R.B.); (A.R.); (L.D.R.); (A.T.); (P.M.); (S.S.); (F.S.)
| | - Luigi De Rosa
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy; (R.B.); (A.R.); (L.D.R.); (A.T.); (P.M.); (S.S.); (F.S.)
| | - Antonia Tortori
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy; (R.B.); (A.R.); (L.D.R.); (A.T.); (P.M.); (S.S.); (F.S.)
| | - Sławomir Wilczyński
- Department of Basic Biomedical Science, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Będzińska Street 39, 41-200 Sosnowiec, Poland;
| | - Paolo Melillo
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy; (R.B.); (A.R.); (L.D.R.); (A.T.); (P.M.); (S.S.); (F.S.)
| | - Sandro Sbordone
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy; (R.B.); (A.R.); (L.D.R.); (A.T.); (P.M.); (S.S.); (F.S.)
| | - Francesca Simonelli
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy; (R.B.); (A.R.); (L.D.R.); (A.T.); (P.M.); (S.S.); (F.S.)
| |
Collapse
|
21
|
Lanza M, Koprowski R, Boccia R, Ruggiero A, De Rosa L, Tortori A, Wilczyński S, Melillo P, Sbordone S, Simonelli F. Classification Tree to Analyze Factors Connected with Post Operative Complications of Cataract Surgery in a Teaching Hospital. J Clin Med 2021; 10:jcm10225399. [PMID: 34830681 DOI: 10.3390/jcm10225399.pmid:34830681;pmcid:pmc8625404] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 11/18/2021] [Accepted: 11/18/2021] [Indexed: 05/22/2023] Open
Abstract
BACKGROUND Artificial intelligence (AI) is becoming ever more frequently applied in medicine and, consequently, also in ophthalmology to improve both the quality of work for physicians and the quality of care for patients. The aim of this study is to use AI, in particular classification tree, for the evaluation of both ocular and systemic features involved in the onset of complications due to cataract surgery in a teaching hospital. METHODS The charts of 1392 eyes of 1392 patients, with a mean age of 71.3 ± 8.2 years old, were reviewed to collect the ocular and systemic data before, during and after cataract surgery, including post-operative complications. All these data were processed by a classification tree algorithm, producing more than 260 million simulations, aiming to develop a predictive model. RESULTS Postoperative complications were observed in 168 patients. According to the AI analysis, the pre-operative characteristics involved in the insurgence of complications were: ocular comorbidities, lower visual acuity, higher astigmatism and intra-operative complications. CONCLUSIONS Artificial intelligence application may be an interesting tool in the physician's hands to develop customized algorithms that can, in advance, define the post-operative complication risk. This may help in improving both the quality and the outcomes of the surgery as well as in preventing patient dissatisfaction.
Collapse
Affiliation(s)
- Michele Lanza
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy
| | - Robert Koprowski
- Institute of Biomedical Engineering, Faculty of Science and Technology, University of Silesia in Katowice, Bedzińska 39, 41-200 Sosnowiec, Poland
| | - Rosa Boccia
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy
| | - Adriano Ruggiero
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy
| | - Luigi De Rosa
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy
| | - Antonia Tortori
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy
| | - Sławomir Wilczyński
- Department of Basic Biomedical Science, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Będzińska Street 39, 41-200 Sosnowiec, Poland
| | - Paolo Melillo
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy
| | - Sandro Sbordone
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy
| | - Francesca Simonelli
- Multidisciplinary Department of Medical, Surgical and Dental Sciences, University of Campania Luigi Vanvitelli, 80100 Napoli, Italy
| |
Collapse
|
22
|
Khoramnia R, Yildirim TM, Weindler J, Naujokaitis T, Dzhambazova M, Auffarth GU. Preloaded injectors used in a clinical study: videographic assessment and laboratory analysis of injector nozzle damage. J Cataract Refract Surg 2021; 47:1338-1344. [PMID: 34469394 DOI: 10.1097/j.jcrs.0000000000000587] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 01/14/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate quality and duration of implantation of 2 preloaded intraocular lens (IOL) injectors and assess postimplantation damage. SETTING The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. DESIGN Prospective, randomized, comparative study with laboratory investigation. METHODS Implantation videos and postuse injectors from 60 paired eyes of 30 bilateral cataract patients were included. Patient eyes were randomly assigned for implantation with 2 different preloaded injectors: the AutonoMe with a Clareon IOL (Alcon Laboratories, Inc.) and the iSert with a Vivinex IOL (Hoya Corp.). Videos were reviewed for events during the implantation procedure, and the duration of each step of implantation. Injector nozzles were examined under light and scanning electron microscopy. Damage was graded and correlated with the IOL power. Three months postoperatively IOLs were assessed for material changes. RESULTS IOL delivery was without any critical events in 60 of the 60 eyes. The implantation took 56 seconds with the AutonoMe and 44 seconds with the iSert (P < .05). Most AutonoMe injectors (29; 97%) showed no damage or slight deformation. In most of the iSert injectors (25; 80%), short or extended cracks were present, and damage lengths correlated with the IOL power. All IOLs were free of material changes, including glistenings, 3 months postoperatively. CONCLUSIONS Both preloaded IOL injectors allowed a safe and convenient IOL delivery. Implantation of the Clareon IOL took, on average, slightly longer than that of the Vivinex IOL, mostly due to a slower IOL unfolding. The AutonoMe showed less nozzle tip damage than that of the iSert.
Collapse
Affiliation(s)
- Ramin Khoramnia
- From the The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | | | | | | | | | | |
Collapse
|
23
|
[Material properties of intraocular lenses: are there patient-relevant differences?]. Ophthalmologe 2021; 118:1066-1067. [PMID: 34477904 DOI: 10.1007/s00347-021-01490-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/12/2021] [Indexed: 10/20/2022]
|
24
|
Tandogan T, Auffarth GU, Choi CY, Son HS, Khoramnia R. Comparative analysis of in vitro accelerated glistening formation in foldable hydrophobic intraocular lenses. Int Ophthalmol 2021; 41:3073-3080. [PMID: 34013467 PMCID: PMC8364527 DOI: 10.1007/s10792-021-01870-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 04/15/2021] [Indexed: 01/30/2023]
Abstract
PURPOSE To analyse and compare the propensity to form glistenings in 4 different types of hydrophobic acrylic intraocular lenses (IOLs): Alcon AcrySof ® MA60AC, HOYA iSert® PC-60AD, Bausch&Lomb enVista, and Kowa Avansee™ PU6A. METHODS We used an accelerated laboratory method to create glistenings. IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h. Microvacuole (MV) density and size were documented and calculated using an image analysis program. RESULTS Median density of glistenings [MV/mm2] for Alcon AcrySof ® MA60AC was 623 (range 507-804), for HOYA iSert® PC-60AD 1358 (range 684-2699), for Bausch&Lomb enVista 2 (range 1-2), and for Kowa Avansee™ PU6A 1 (range 1-4). The prevailing MV size was: 0-5 µm for Hoya IOLs, 5-10 µm for Alcon IOLs, 20-50 µm for Bausch&Lomb IOLs, and 5-50 µm for Kowa IOLs. CONCLUSIONS Glistenings could be induced in all studied IOLs using the accelerated laboratory method. The Alcon AcrySof ® MA60AC and HOYA iSert® PC-60AD IOLs showed MV of high density, while the glistenings in the Hoya IOLs were smaller in size compared to the Alcon IOLs. The MV density was minimal in the Bausch&Lomb enVista and Kowa Avansee™ PU6A IOLs. The propensity of the Alcon AcrySof ® MA60AC IOLs to form glistenings in vitro correlated with the findings of clinical results that are already published.
Collapse
Affiliation(s)
- Tamer Tandogan
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Gerd U. Auffarth
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
| |
Collapse
|
25
|
Son HS, Łabuz G, Khoramnia R, Yildirim TM, Choi CY, Knorz MC, Auffarth GU. Visualization of Forward Light Scatter in Opacified Intraocular Lenses and Straylight Assessment. Diagnostics (Basel) 2021; 11:diagnostics11081512. [PMID: 34441445 PMCID: PMC8393541 DOI: 10.3390/diagnostics11081512] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 08/10/2021] [Accepted: 08/20/2021] [Indexed: 11/16/2022] Open
Abstract
Background: Qualitative visualization of forward light scatter and quantitative straylight measurement of intraocular lenses (IOLs). Methods: We analyzed two calcified IOL-explants, the Euromaxx ALI313Y (Argonoptics GmbH) and the LS-312 MF30 (Oculentis BV), one IOL with artificially induced glistenings (PC-60AD, Hoya), and one control (CT Asphina 409MP, Carl Zeiss Meditec AG) free of any opacification. Analysis included light microscopy, qualitative light scatter visualization using ray propagation imaging technique, and quantitative straylight measurement using C-Quant (Oculus). Results: More light scattering effect—visible as increased light intensity outside the IOL’s main focus—was evident in all opacified IOLs than the control. The highest straylight levels were observed in the Euromaxx (289.71 deg2/sr), which showed extensive granular deposits throughout its optic, followed by the MF30 (78.58 deg2/sr), which only showed opacification in its center. The glistenings-IOL demonstrated numerous microvacuoles within the optic and had straylight levels of 22.6 deg2/sr, while the control showed the lowest straylight levels (1.7 deg2/sr). Conclusions: Ray propagation imaging technique allowed qualitative assessment of off-axis veils of light that result from increased forward light scattering. Straylight was increased in all opacified lenses compared to the clear control lens. The IOL opacifications are significant sources of glare.
Collapse
Affiliation(s)
- Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
| | - Grzegorz Łabuz
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
| | - Timur M. Yildirim
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
| | - Chul Young Choi
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181, Korea
| | - Michael C. Knorz
- FreeVis LASIK Center, Medical Faculty Mannheim of the University of Heidelberg, 68167 Mannheim, Germany;
| | - Gerd U. Auffarth
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, 69117 Heidelberg, Germany; (H.-S.S.); (G.Ł.); (R.K.); (T.M.Y.); (C.Y.C.)
- Correspondence:
| |
Collapse
|
26
|
Yildirim TM, Łabuz G, Hammer M, Son HS, Schickhardt SK, Auffarth GU, Khoramnia R. A Novel Approach for Assessing Visual Impairment Caused by Intraocular Lens Opacification: High-Resolution Optical Coherence Tomography. Am J Ophthalmol 2021; 226:108-116. [PMID: 33571474 DOI: 10.1016/j.ajo.2021.02.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 01/16/2021] [Accepted: 02/02/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE To quantify in vitro straylight induced by intraocular lens (IOL) localized opacification using an anterior segment optical coherence tomography (OCT) device. DESIGN Laboratory investigation. METHODS We obtained high-resolution OCT cross-section images of 44 explanted IOLs using a new in vitro application for an anterior segment OCT device, the Anterion (Heidelberg Engineering, Heidelberg, Germany). In 24 cases, the reason for IOL explantation was a centrally localized opacification, the sequela of a secondary ocular surgery. As a control, we used 20 IOLs removed after an IOL (sub-)luxation. Using image analysis, we found a threshold area value representing a metric for the amount of opacification in a region of interest in the IOL's central optic. We used a modified C-Quant straylight meter (Oculus, Wetzlar, Germany) to quantify light scattering. We derived a linear regression from calculating the correlation between the amount of opacification and straylight. RESULTS We visualized different amounts of IOL opacification using the OCT device. The opacified lenses showed a mean threshold area of 6.7% ± 3.3% and mean straylight was 95.1 ± 75.6 deg2/sr. The clear group's mean threshold area was 2.0% ± 0.8% and 5.0 ± 3.4 deg2/sr mean straylight. Straylight correlated statistically significantly with the threshold area, with a correlation coefficient of R2 = 0.80, P < .001. CONCLUSIONS This high-resolution OCT imaging technique can be used to visualize IOL opacities. The amount of opacification correlated well with the straylight induced by the lens. Anterior segment OCT imaging might be used in the future as a tool for predicting the extent of visual impairment and aid clinicians to quantify patients' complaints.
Collapse
|
27
|
Fernández J, Rodríguez-Vallejo M, Martínez J, Burguera N, Piñero DP. What we have learnt from 30 years living with positive dysphotopsia after intraocular lens implantation?: a review. EXPERT REVIEW OF OPHTHALMOLOGY 2021. [DOI: 10.1080/17469899.2021.1917997] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- Joaquín Fernández
- Department of Ophthalmology (Qvision, VITHAS Hospital, Almería, Spain
| | | | - Javier Martínez
- Department of Ophthalmology (Qvision, VITHAS Hospital, Almería, Spain
| | - Noemi Burguera
- Department of Ophthalmology (Qvision, VITHAS Hospital, Almería, Spain
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
- Department of Ophthalmology (Imqo-oftalmar), Vithas Medimar International Hospital, Alicante, Spain
| |
Collapse
|
28
|
Abstract
The spectrum of complications in the use of intraocular lenses (IOL) is different today from at the time of their introduction. Opacities in the IOL material are increasingly described in the literature as a reason for IOL explantation. This paper provides an overview of the different forms of IOL material opacities. Currently relevant forms of IOL material opacities and their effects on optical quality are summarized. The main reason for opacification in hydrophilic IOLs is calcification, whereas in hydrophobic IOLs it is mainly the formation of so-called glistenings that is reported. Most material opacities affect various optical parameters and lead to increased intraocular straylight. In case of a disturbing material opacification, the only therapeutic option is to replace the opacified IOL.
Collapse
|
29
|
Khoramnia R. Eintrübung von Intraokularlinsen. AUGENHEILKUNDE UP2DATE 2021. [DOI: 10.1055/a-1250-3703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
ZusammenfassungDas Spektrum an Komplikationen und die Explantationsgründe bei der Verwendung von
Intraokularlinsen (IOL) haben sich durch die Weiterentwicklung der
Kataraktchirurgie verändert. Eintrübungen des Materials beeinflussen dabei
unterschiedlich stark die optische Qualität. Im Fall einer störenden Eintrübung
des Materials ist auch heute noch – trotz aller Fortschritte auf dem Gebiet der
IOL-Materialien – ein Austausch der IOL die einzige Behandlungsoption.
Collapse
|
30
|
Tandogan T, Auffarth GU, Son HS, Merz P, Choi CY, Khoramnia R. In-vitro glistening formation in six different foldable hydrophobic intraocular lenses. BMC Ophthalmol 2021; 21:126. [PMID: 33685428 PMCID: PMC7938589 DOI: 10.1186/s12886-021-01879-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 02/18/2021] [Indexed: 11/26/2022] Open
Abstract
Background Glistenings describe small, refractile microvacuoles that may arise within the intraocular lens (IOL) material and reduce the patients’ quality of vision. Lenses composed of hydrophobic acrylic material are particularly affected by glistening formation. In this study, we compared the tendency of glistening formation in six different types of hydrophobic acrylic intraocular lenses (IOLs). Methods We used a well-established accelerated laboratory method to develop glistenings in the following IOLs: Vivinex XY1 (Hoya), AcrySof SN60WF (Alcon), Tecnis ZCB00 (AMO), Avansee PN6A (Kowa), Aktis SP NS-60YG (Nidek), and CT Lucia 601P (Zeiss). IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h in a water bath. Microvacuole (MV) density and size (Miyata grading) were documented and calculated using an image analysis program. Results The mean glistening density [MV/mm2] and mean Miyata grading (in brackets) were: Vivinex: 11.6 ± 5.7 (0), SN60WF: 264.4 ± 110.3 (2.6), Tecnis: 6.0 ± 2.8 (0), Avansee: 2.2 ± 0.7 (0), Aktis: 851.4 ± 59.4 (3+) and CT Lucia: 71.0 ± 71.6 (1). Conclusions While all tested IOLs showed glistenings with the accelerated laboratory method, the Aktis and SN60WF showed the highest microvacuole density, followed by the CT Lucia. In comparison, the Vivinex, Tecnis, and Avansee IOLs showed far fewer number of glistenings.
Collapse
Affiliation(s)
- Tamer Tandogan
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Gerd U Auffarth
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany.
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Patrick Merz
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University, Seoul, South Korea
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| |
Collapse
|