Hart I, Wells C, Tsigarida A, Bezerra B. Effectiveness of mechanical and chemical decontamination methods for the treatment of dental implant surfaces affected by peri-implantitis: A systematic review and meta-analysis.
Clin Exp Dent Res 2024;
10:e839. [PMID:
38345466 PMCID:
PMC10847712 DOI:
10.1002/cre2.839]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 12/20/2023] [Accepted: 12/30/2023] [Indexed: 02/15/2024] Open
Abstract
OBJECTIVE
To assess which decontamination method(s) used for the debridement of titanium surfaces (disks and dental implants) contaminated with bacterial, most efficiently eliminate bacterial biofilms.
MATERIAL AND METHODS
A systematic search was conducted in four electronic databases between January 1, 2010 and October 31, 2022. The search strategy followed the PICOS format and included only in vitro studies completed on either dental implant or titanium disk samples. The assessed outcome variable consisted of the most effective method(s)-chemical or mechanical- removing bacterial biofilm from titanium surfaces. A meta-analysis was conducted, and data was summarized through single- and multi-level random effects model (p < .05).
RESULTS
The initial search resulted in 5260 articles after the removal of duplicates. After assessment by title, abstract, and full-text review, a total of 13 articles met the inclusion criteria for this review. Different decontamination methods were assessed, including both mechanical and chemical, with the most common method across studies being chlorhexidine (CHX). Significant heterogeneity was noted across the included studies. The meta-analyses only identified a significant difference in biofilm reduction when CHX treatment was compared against PBS. The remaining comparisons did not identify significant differences between the various decontamination methods.
CONCLUSIONS
The present results do not demonstrate that one method of decontamination is superior in eliminating bacterial biofilm from titanium disk and implant surfaces.