• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4611082)   Today's Articles (280)   Subscriber (49381)
For: Resende CC, Castro CG, Pereira LM, Prudente MS, Zancopé K, Davi LR, Penatti MP, das Neves FD. Influence of the Prosthetic Index Into Morse Taper Implants on Bacterial Microleakage. IMPLANT DENT 2015;24:547-51. [PMID: 26068320 DOI: 10.1097/ID.0000000000000284] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Number Cited by Other Article(s)
1
Goyeneche VP, Cortellari GC, Rodriguez F, De Aza PN, Maria da Costa E, Scarano A, Júnior NDB, Gehrke SA. Does the index in Morse taper connection affect the abutment stability? An in vitro experimental study. PLoS One 2024;19:e0298462. [PMID: 38457413 PMCID: PMC10923422 DOI: 10.1371/journal.pone.0298462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 01/24/2024] [Indexed: 03/10/2024]  Open
2
Shen L, Dong C, Chen J, Bai X, Yang F, Wang L. The mechanical and clinical influences of prosthetic index structure in Morse taper implant-abutment connection: a scoping review. BMC Oral Health 2023;23:775. [PMID: 37865734 PMCID: PMC10590505 DOI: 10.1186/s12903-023-03545-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 10/16/2023] [Indexed: 10/23/2023]  Open
3
Bacterial infiltration and detorque at the implant abutment morse taper interface after masticatory simulation. Sci Rep 2022;12:17103. [PMID: 36224228 PMCID: PMC9556662 DOI: 10.1038/s41598-022-20915-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 09/20/2022] [Indexed: 01/04/2023]  Open
4
Zhang WT, Cheng KJ, Liu YF, Wang R, Chen YF, Ding YD, Yang F, Wang LH. Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis. BMC Oral Health 2022;22:431. [PMID: 36180871 PMCID: PMC9523891 DOI: 10.1186/s12903-022-02465-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 09/19/2022] [Indexed: 11/23/2022]  Open
5
Fathi A, Rismanchian M, Dezaki SN. Effectiveness of Different Antimicrobial Agents on Malodor Prevention in Two-Stage Dental Implants: A Double-Blinded Randomized Clinical Trial. Eur J Dent 2022. [PMID: 35820442 DOI: 10.1055/s-0042-1747954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]  Open
6
Effect of Implant-Abutment Connection Type on Bone Around Dental Implants in Long-Term Observation: Internal Cone Versus Internal Hex. IMPLANT DENT 2019;28:430-436. [PMID: 31188171 DOI: 10.1097/id.0000000000000905] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
7
Mishra SK, Chowdhary R, Kumari S. Microleakage at the Different Implant Abutment Interface: A Systematic Review. J Clin Diagn Res 2017;11:ZE10-ZE15. [PMID: 28764310 DOI: 10.7860/jcdr/2017/28951.10054] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Accepted: 05/20/2017] [Indexed: 12/21/2022]
8
In Vitro Microbiological Analysis of Bacterial Seal in Hybrid Zirconia Abutment Tapered Connection. IMPLANT DENT 2016;26:245-249. [PMID: 28005570 DOI: 10.1097/id.0000000000000533] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA