1
|
Gross G, Schmohl L, Fuchs F, Guenther E, Schulz-Siegmund M, Schoengart J, Hahnel S, Koenig A. Retention force, translucency, and microstructural properties of translucent temporary luting cements: An in vitro study. J Mech Behav Biomed Mater 2023; 142:105781. [PMID: 37062100 DOI: 10.1016/j.jmbbm.2023.105781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 03/09/2023] [Accepted: 03/12/2023] [Indexed: 04/05/2023]
Abstract
The aim of the study was to investigate the retention behaviour (pull-off force include adhesive remnant index = ARI) as well as translucency of various temporary luting cements and use microstructure elucidation methods to formulate explanatory approaches to their mode of action. The retention force of the temporary luting cements Provicol QM Plus (P+), Provicol QM Aesthetic (Pae), Bifix Temp (BiT), and as a reference a glass ionomer cement Meron (M) with a direct (Structur 3/S3) or an indirect (Structure CAD/SCAD) resin-based composite restauration was investigated after accelerated aging (thermocycling). Additional investigation of the physical properties was performed regarding to translucency and surface free energy. The microstructure was evaluated by X-ray diffraction, thermogravimetric analysis, differential scanning calorimetry and micro X-ray computed tomography. All tested temporary luting cements showed different pull-off forces in the range between 3.0 and 16.8 N in combination with S3 or SCAD after thermocycling. Only BiT with S3 showed pull-off forces of 129.2 N and complete retention on the restoration (ARI = 0), which was significant (p < .001) to all other samples. High translucency (BiT > Pae > M > P+) was observed for materials with lower crystalline content and low residual mass (usally resulting from higher organic content). M showed the highest surface free energy with a predominantly polar fraction, while BiT had a predominantly dispersive fraction. The highest porosity was observed in the coronal region of the restoration. The results suggest that translucency of temporary luting cements can be increased with higher organic and lower cryristall content. All combinations of cements and temporary restorations (direct/indirect; with the exception of BiT/S3) showed pull-off forces below 17 N (equivalent to a weight force of ∼1.7 kg), which allows manual detachment of the restoration by the dentist.
Collapse
Affiliation(s)
- Goeran Gross
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103, Leipzig, Germany
| | - Leonie Schmohl
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103, Leipzig, Germany
| | - Florian Fuchs
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103, Leipzig, Germany
| | - Elena Guenther
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103, Leipzig, Germany
| | | | - Jann Schoengart
- Institute of Mineralogy, Crystallography and Materials Science, Leipzig University, 04275, Leipzig, Germany
| | - Sebastian Hahnel
- Department of Prosthetic Dentistry, University Hospital of Regensburg, 93053, Regensburg, Germany
| | - Andreas Koenig
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103, Leipzig, Germany.
| |
Collapse
|
2
|
Dehno SMS, Giti R, Kalantari MH, Mohammadi F. The effects of provisional resin cements on the color and retentive strength of all-ceramic restorations cemented on customized zirconia abutments. PLoS One 2022; 17:e0262582. [PMID: 35041706 PMCID: PMC8765607 DOI: 10.1371/journal.pone.0262582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 12/30/2021] [Indexed: 11/21/2022] Open
Abstract
This study aimed to evaluate the effects of two types of provisional resin cements on the color and retentive strength of two different all-ceramic restorations cemented onto customized zirconia abutments. Forty-two crowns were made of monolithic zirconia and lithium disilicate ceramics (n = 21 per group) and cemented on customized zirconia abutments by using two provisional resin cements of TempBond Clear and Implantlink Semi, and TempBond serving as the control (n = 7 per cement subgroup). The specimens’ color was measured before and after cementation and after thermocycling. The color difference was calculated by using CIEDE2000 formula (ΔE00). The tensile force was applied to assess the retentive strength. Kruskal-Wallis, Dunn’s post-hoc, and Mann-Whitney non-parametric tests were used to compare ΔE00(1) and ΔE00(2) and two-way ANOVA followed by one-way ANOVA and Tukey’s HSD post hoc test and T-test were used to compare retentive strength between subgroups. In the lithium disilicate group, ΔE00 of the control subgroup (TempBond) was significantly higher than that of Implantlink Semi cements subgroup (P = 0.001). But, in the monolithic zirconia group, ΔE00 of the control subgroup (TempBond) was significantly higher than that of Implantlink Semi (P = 0.020) and TempBond Clear cements (P = 0.007). In the monolithic zirconia group, the control subgroup (TempBond) was significantly more retentive than TempBond Clear (P = 0.003) and Implantlink Semi cement (P = 0.001). However, in the lithium disilicate group, Implantlink Semi cement was significantly more retentive than TempBond Clear (P = 0.019) and TempBond (control) (P = 0.001). The final color of both restorations was significantly affected by the provisional resin cement type. The retentive strength was influenced by both the type of cement and ceramic.
Collapse
Affiliation(s)
- Seyede Mina Salehi Dehno
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Rashin Giti
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
- * E-mail:
| | - Mohammad Hassan Kalantari
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Farhad Mohammadi
- Department of Pharmaceutics, School of Pharmacy, Shahid Sadoughi University of Medical Sciences and Health Care Services, Yazd, Iran
| |
Collapse
|
3
|
Soares PM, Cadore-Rodrigues AC, Souto Borges AL, Valandro LF, Pereira GKR, Rippe MP. Load-bearing capacity under fatigue and FEA analysis of simplified ceramic restorations supported by Peek or zirconia polycrystals as foundation substrate for implant purposes. J Mech Behav Biomed Mater 2021; 123:104760. [PMID: 34418777 DOI: 10.1016/j.jmbbm.2021.104760] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 07/29/2021] [Accepted: 08/03/2021] [Indexed: 11/17/2022]
Abstract
The fatigue behavior and FEA analysis of different ceramic materials cemented over distinct substrates for implant-supported crowns were evaluated in this study. Discs of 10 mm in diameter of both restorative and substrate materials were made and randomly allocated into pairs (n = 15) considering the two study factors: 'restorative ceramic material' (1 mm thickness) - polymer-infiltrated ceramic network (PICN), lithium disilicate (LD), zirconia-reinforced lithium silicate (ZLS), or translucent zirconia (TZ); and 'foundation substrate' (2 mm thickness) - polyetheretherketone (Peek) or yttrium-stabilized zirconia (YZ). Adhesive cementation was made with a dual cure resin cement. Fatigue testing was run using the step-stress methodology: initial load of 200 N for 5000 cycles, followed by steps of 10,000 cycles starting at 400 N up to 2800 N or until failure, step size of 200 N, frequency of 20 Hz. Data were analyzed by the Kaplan Meier and log-rank post-hoc tests. Fractography analysis (stereomicroscope and SEM) and FEA were also performed. Both factors under study and their interaction statistically influenced the fatigue failure load (FFL), cycles for failure (CFF) and survival rates (p < 0.001). The restorative materials bonded to YZ had higher FFL and CFF than when adhering to Peek, while restorative materials with more crystalline content (TZ and ZLS) showed higher FFL and CFF than LD and PICN. The fractography analysis showed that all materials bonded to YZ resulted in failures starting at the occlusal surface (Hertzian cone cracks), while materials bonded to Peek had radial cracks from the ceramic-cement intaglio surface. FEA analysis showed that tensile stress concentration decreased in the intaglio surface when testing the restorative material over a stiffer (YZ) foundation substrate. In addition, the higher the restorative material's crystalline content, the more the stress is concentrated within the material (TZ > ZLS ≥ LD > PICN) when bonded to the same foundation substrate. Thus, it concluded that a stiffer foundation substrate (YZ) enhances the load-bearing capacity under fatigue of the restorative set; that restorative materials with higher crystalline content results in higher fatigue performance of the set, regardless of the foundation used; and that the foundation material influences the failure pattern of the restorative set.
Collapse
Affiliation(s)
- Pablo Machado Soares
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Ana Carolina Cadore-Rodrigues
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Alexandre Luiz Souto Borges
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
4
|
Dähne F, Meißner H, Böning K, Arnold C, Gutwald R, Prause E. Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro. Int J Implant Dent 2021; 7:62. [PMID: 34282495 PMCID: PMC8289925 DOI: 10.1186/s40729-021-00349-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 04/22/2021] [Indexed: 11/25/2022] Open
Abstract
Purpose The aim of the present study was to examine the retention force of monolithic zirconia copings cemented with various temporary cements on implant abutments in vitro. Methods Sixty exercise implants with pre-screwed implant abutments were embedded in resin. Subsequently, 60 CAD/CAM manufactured zirconia copings were divided into three main groups [Harvard Implant Semi-permanent (HAV), implantlink semi Forte (IMP), Temp Bond NE (TBNE)]. The zirconia copings were cemented on the implant abutments and loaded with 35 N. Specimens were stored in distilled water (37 °C) for 24 h. Half of the test specimens of each group were subjected to a thermocycling (TC) process. Retention force was measured in a universal testing machine. Using magnifying glasses, the fracture mode was determined. Statistical analysis was performed applying the Kruskal-Wallis test, the post hoc test according to Dunn-Bonferroni and a chi-square test of independence. Results Without TC, IMP showed the highest retention of the three temporary luting agents (100.5 ± 39.14 N). The measured retention forces of IMP were higher than those of HAV (45.78 ± 15.66 N) and TBNE (61.16 ± 20.19 N). After TC, retention was reduced. IMP showed the greatest retentive strength (21.69 ± 13.61 N, three fail outs). HAV and TBNE showed pull-off forces of similar magnitude (17.38 ± 12.77 N and 16.97 ± 12.36 N, two fail outs). The fracture mode analysis showed different results regarding the tested cements before and after TC (facture type before/after TC): IMP (III+II/III), HAV (I/II) and TBNE (III/III). There were clear differences of the fracture modes regarding the examination before and after TC. Conclusions Within the limits of this study, IMP showed the highest pull-off forces under the chosen test conditions. All three temporary luting agents showed lower retention forces after TC. Retention values in the individual cement classes were very heterogeneous. Easy cement removal in the crown lumen favours the dominance of adhesive cement fractures on the abutment and adhesive/cohesive cement fractures on the abutment with HAV appears advantageous in case of recementation of the superstructure.
Collapse
Affiliation(s)
- Felix Dähne
- Department of Oral and Plastic Maxillofacial Surgery, University Hospital Halle, Martin Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120, Halle, Germany
| | - Heike Meißner
- Department of Prosthodontics, Carl Gustav Carus Faculty of Medicine, University of Technology, Fetscherstrasse 74, 01307, Dresden, Germany
| | - Klaus Böning
- Department of Prosthodontics, Carl Gustav Carus Faculty of Medicine, University of Technology, Fetscherstrasse 74, 01307, Dresden, Germany
| | - Christin Arnold
- Department of Prosthodontics, School of Dental Medicine, Martin-Luther-University, Magdeburger Str. 16, 06112, Halle, Germany
| | - Ralf Gutwald
- Faculty of Medicine/Dentistry, Danube Private University (DPU), Steiner Landstraße 124, 3500, Krems-Stein, Austria
| | - Elisabeth Prause
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, University Charité Berlin, Aßmannshauser Str. 4-6, 14197, Berlin, Germany.
| |
Collapse
|
5
|
Retention of zirconia copings over smooth and airborne-particle-abraded titanium bases with different resin cements. J Prosthet Dent 2019; 121:949-954. [PMID: 30711294 DOI: 10.1016/j.prosdent.2018.08.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 08/15/2018] [Accepted: 08/15/2018] [Indexed: 02/04/2023]
Abstract
STATEMENT OF PROBLEM How cement type and the surface treatment of a titanium base affect the retention of zirconia copings on titanium bases is unclear. PURPOSE The purpose of this in vitro study was to evaluate the dislodging forces of zirconium oxide copings cemented on implant-supported titanium bases with different luting agents and to examine the influence of airborne-particle abrasion on titanium surfaces. MATERIAL AND METHODS Thirty implant laboratory analogs (BioHorizons) were fixed in metal blocks, and 30 prosthetic titanium bases (BioHorizons) were tightened with 35 Ncm of torque. Zirconium oxide copings with a luting-gap size of 30 μm were produced by using the Lava (3M ESPE) technology. The specimens were bonded to the titanium bases with 3 different resin cements (G-CEM LinkAce, RelyX U200, and Ceka Site). The specimens were kept in artificial saliva at 37°C for 24 hours and then subjected to a dynamic loading of 5000 cycles with a mastication simulator (SD Mechatronic) with thermocycling between 5°C and 55°C. The tensile force was measured by using a universal testing machine (Zwick/Roell) at a crosshead speed of 5 mm/min. After the measurement, the cement was cleaned from the titanium bases and zirconia copings. The titanium bases were airborne-particle abraded with 50-μm aluminum oxide (Al2O3) particles, and the bonding process was repeated. The statistical analysis included descriptive analysis, 2-way ANOVA, the Tukey post hoc, and simple main effect tests (α=.05). RESULTS Bond strengths were significantly different according to the cement type used and before and after airborne-particle abrasion (P<.05). The cement retentiveness before airborne-particle abrasion was as follows: G-CEM LinkAce (1338 ±69 N)>RelyX U200 (665 ±36 N)>Ceka Site (469 ±22 N). The differences among all the cement types before airborne-particle abrasion were statistically significant (P<.05). After airborne-particle abrasion, retention decreased in all the groups, and the ranking of the cements' retentiveness remained the same: G-CEM LinkAce (662 ±65 N)>RelyX U200 (352 ±21 N)>Ceka Site (122 ±17 N). After airborne-particle abrasion, the differences among all the cements remained statistically significant (P<.05). The comparison within the groups before and after airborne-particle abrasion revealed that abrading the titanium bases with 50-μm Al2O3 decreased the bond strength for all the tested cements. CONCLUSIONS The cement type had a significant influence on the retention of the zirconia copings, and abrading the titanium bases with 50-μm Al2O3 significantly decreased the dislodging force of the coping from the titanium base.
Collapse
|