1
|
Kim K, Koh K, Lee S, Lee Y. Diagnostic Validation of the Screening Corneal Objective Risk of Ectasia Analyzer Evaluated by Swept Source Optical Coherence Tomography for Keratoconus in an Asian Population. Bioengineering (Basel) 2023; 10:1335. [PMID: 38002459 PMCID: PMC10669067 DOI: 10.3390/bioengineering10111335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 10/27/2023] [Accepted: 11/16/2023] [Indexed: 11/26/2023] Open
Abstract
We aimed to investigate the diagnostic accuracy of Screening Corneal Objective Risk of Ectasia (SCORE) Analyzer software using ANTERION, a swept-source optical coherence tomography device, for keratoconus diagnosis in an Asian population. A total of 151 eyes of 151 patients were included in this retrospective study as follows: 60, 45, and 46 keratoconus, keratoconus suspects, and normal control eyes, respectively. Parameters in the SCORE calculation, including six indices, were compared for the three groups. The receiver operating characteristic curve analysis and cut-off value were estimated to assess the diagnostic ability to differentiate keratoconus and keratoconus suspect eyes from the normal group. The SCORE value and six indices were significantly correlated-"AntK max" (R = 0.864), "AntK oppoK" (R = 0.866), "Ant inf supK" (R = 0.943), "Ant irre 3mm" (R = 0.741), "post elevation at the thinnest point" (R = 0.943), and "minimum corneal thickness" (R = -0.750). The SCORE value showed high explanatory power (98.1%), sensitivity of 81.9%, and specificity of 78.3% (cut-off value: 0.25) in diagnosing normal eyes from the keratoconus suspect and keratoconus eyes. The SCORE Analyzer was found to be valid and consistent, showing good sensitivity and specificity for keratoconus detection in an Asian population.
Collapse
Affiliation(s)
| | - Kyungmin Koh
- Kim’s Eye Hospital, Seoul 07301, Republic of Korea
| | - Seongjun Lee
- Nuri Eye Hospital, Daejeon 35233, Republic of Korea
| | - Yongwoo Lee
- Departement of Ophthalmology, Kangwon National University Hopsital, Kangwon National University School of Medicine, Chuncheon, Gangwon 24289, Republic of Korea
| |
Collapse
|
2
|
Naujokaitis T, Auffarth GU, Łabuz G, Kessler LJ, Khoramnia R. Diagnostic Techniques to Increase the Safety of Phakic Intraocular Lenses. Diagnostics (Basel) 2023; 13:2503. [PMID: 37568866 PMCID: PMC10417808 DOI: 10.3390/diagnostics13152503] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/25/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023] Open
Abstract
Preoperative and postoperative diagnostics play an important role in ensuring the safety of patients with phakic intraocular lenses (pIOLs). The risk of endothelial cell loss can be addressed by regularly measuring the endothelial cell density using specular microscopy and considering the endothelial cell loss rate and the endothelial reserve in accordance with the patient's age when deciding whether to explant a pIOL. The anterior chamber morphometrics, including the anterior chamber depth and the distance between the pIOL and the endothelium, measured using Scheimpflug tomography and anterior segment optical coherence tomography (AS-OCT), can help to assess the risk of the endothelial cell loss. In patients undergoing posterior chamber pIOL implantation, accurate prediction of the vault and its postoperative measurements using AS-OCT or Scheimpflug tomography are important when assessing the risk of anterior subcapsular cataract and secondary glaucoma. Novel approaches based on ultrasound biomicroscopy and AS-OCT have been proposed to increase the vault prediction accuracy and to identify eyes in which prediction errors are more likely. Careful patient selection and regular postoperative follow-up visits can reduce the complication risk and enable early intervention if a complication occurs.
Collapse
Affiliation(s)
| | | | | | | | - Ramin Khoramnia
- Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany
| |
Collapse
|
3
|
Mirzayev I, Gündüz AK, Aydın Ellialtıoğlu P, Gündüz ÖÖ. Clinical applications of anterior segment swept-source optical coherence tomography: A systematic review. Photodiagnosis Photodyn Ther 2023; 42:103334. [PMID: 36764640 DOI: 10.1016/j.pdpdt.2023.103334] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 01/25/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023]
Abstract
Optical coherence tomography (OCT) is a non-invasive method that provides the opportunity to examine tissues by taking cross-sectional images. OCT is increasingly being used to evaluate anterior segment (AS) pathologies. Swept-source (SS) OCT allows greater penetration and achieves better visualization of the internal configuration of AS tissues due to the longer wavelength employed and high scan speeds. We reviewed the utilization of AS SS-OCT in various conditions including glaucoma, ocular surface pathologies, iris tumors, refractive surgery, cataract surgery, and scleral diseases. A systematic literature search was carried out on PubMed, Scopus, and Web of Science databases between January 1, 2008, and September 1, 2022 using the following keywords: AS SS-OCT; dry eye and SS-OCT; ocular surface and SS-OCT; cornea and SS-OCT; dystrophy and SS-OCT; glaucoma and SS-OCT; ocular surface tumors and SS-OCT; conjunctival tumors and SS-OCT; refractive surgery and SS-OCT; cataract and SS-OCT; biometry and SS-OCT; sclera and SS-OCT; iris and SS-OCT; ciliary body and SS-OCT; artificial intelligence and SS-OCT. A total of 221 studies were included in this review. Review of the existing literature shows that SS-OCT offers several advantages in the diagnosis of AS diseases. Exclusive features of SS-OCT including rapid scanning, deeper tissue penetration, and better image quality help improve our understanding of various AS pathologies.
Collapse
Affiliation(s)
- Ibadulla Mirzayev
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Halil Şıvgın Çubuk State Hospital, Ophthalmology Clinic, Ankara, Turkey
| | - Ahmet Kaan Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Private Eye Clinic, Ankara, Turkey.
| | | | - Ömür Özlenen Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
4
|
Evaluation of angle-to-angle and spur-to-spur using swept source optical coherence tomography in different refractive error. PLoS One 2022; 17:e0277703. [PMID: 36409673 PMCID: PMC9678276 DOI: 10.1371/journal.pone.0277703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Accepted: 11/02/2022] [Indexed: 11/22/2022] Open
Abstract
PURPOSE To measure angle-to-angle (ATA) and spur-to-spur (STS) distances along six meridians using swept-source optical coherence tomography (SS-OCT) and compare with horizontal white-to-white (WTW) distance in different refractive error. METHODS Overall, 126 eyes were assessed with the Anterion SS-OCT (Heidelberg Engineering, Heidelberg, Germany). ATA and STS distances were obtained using SS-OCT at 0, 30, 60, 90, 120, and 150 degrees. WTW was measured at 0 degree with built-in infrared camera. One way ANOVA test, pearson correlation coefficient, and stepwise multivariate regression analysis were used to compare ATA and STS distances with age, anterior chamber depth (ACD), axial length (AL), and simulated keratometric values (Sim K) in different refractive error groups. RESULTS The mean MRSE refraction was +0.05 ± 0.23 D in the emmetropic group (41 eyes), -3.42 ± 3.04 D in the myopic group (44 eyes), and +1.33 ± 0.64 D in the hyperopic group (31 eyes). There was no statistical difference in the WTW of the emmetropic (11.62 ± 0.44 mm), myopic (11.79 ± 0.46 mm), and hyperopic groups (11.80 ± 0.49 mm) using one-way ANOVA (p = 0.007). ATA and STS were vertically oval in all groups. The correlation between ATA, STS and age, ACD, AL, and K values showed different significance for each meridian according to the refractive error. ATA increased as the horizontal WTW, ACD, and AL increased and Sim K decreased. STS shows relatively smaller explanatory power than ATA in the stepwise multivariate regression analysis. CONCLUSIONS This study is the first to analyze the relationship between ATA and STS compared to WTW by different refractive error. The difference between the horizontally oval WTW and vertically oval anterior chamber can be large, especially in myopia. ATA showed a greater positive correlation than STS with AL and ACD.
Collapse
|
5
|
Yu B, Wang K, Zhang X, Xing X. Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography. BMC Ophthalmol 2022; 22:222. [PMID: 35578256 PMCID: PMC9109390 DOI: 10.1186/s12886-022-02448-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 05/10/2022] [Indexed: 12/04/2022] Open
Abstract
Background Primary angle closure glaucoma (PACG) is the most common type of glaucoma in China. Laser peripheral iridotomy (LPI) is the primary choice to treat PAC: We aim to evaluate the changes of biometric parameters of anterior segment and to find possible biometric predictors of the effect of laser peripheral iridotomy (LPI) in primary angle closure (PAC) eyes using swept-source optical coherent tomography (OCT). Methods LPI was performed in 52 PAC eyes of 28 participants. The change of intraocular pressure and anterior segment parameters, including angle opening distance (AOD500), AOD500 area, trabecular iris space area (TISA500), TISA500 volume, trabecular iris angle (TIA500), iridotrabecular contact (ITC) index, ITC area, anterior chamber volume (ACV), anterior chamber depth (ACD), lens vault (LV) and lens thickness (LT) before and 1 week after LPI were measured by Tomey CASIA2 anterior segment OCT. We also estimate and analyze potential associated factors possibly affecting the change of anterior chamber parameters. Results No post-laser complications were found. The ACD, LV and LT did not change significantly 1 week after LPI. AOD500, AOD500 area, TISA500, TISA500 volume, TIA500, ACV increased significantly after LPI. There was significant decrease in ITC index and ITC area. LT was positively correlated to the change of ITC index (β = 0.239, *p = 0.045). Conclusions The anterior segment architecture significantly changed after LPI in PAC spectrum eyes. Crystalline lens measurements remained unchanged before and after LPI. AS-OCT can be used to follow anterior chamber parameter changes in PAC spectrum eyes. LT may play a role in the therapeutic effect of LPI.
Collapse
Affiliation(s)
- Bo Yu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Nankai District, No. 251, Fukang Road, Tianjin, 300384, China
| | - Kang Wang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Nankai District, No. 251, Fukang Road, Tianjin, 300384, China
| | - Xiaomin Zhang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Nankai District, No. 251, Fukang Road, Tianjin, 300384, China.
| | - Xiaoli Xing
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Nankai District, No. 251, Fukang Road, Tianjin, 300384, China.
| |
Collapse
|
6
|
Wanichwecharungruang B, Amornpetchsathaporn A, Wongwijitsook W, Kongsomboon K, Chantra S. Evaluation of ocular biometry in primary angle-closure disease with two swept source optical coherence tomography devices. PLoS One 2022; 17:e0265844. [PMID: 35312733 PMCID: PMC8936461 DOI: 10.1371/journal.pone.0265844] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 03/09/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose
To investigate agreement between 2 swept source OCT biometers, IOL Master700 and Anterion, in various ocular biometry and intraocular lens (IOL) calculations of primary angle-closure disease (PACD).
Setting
Rajavithi Hospital, Bangkok, Thailand.
Design
Prospective comparative study.
Methods
This study conducted in a tertiary eye care center involving biometric measurements obtained with 2 devices in phakic eye with diagnosis of PACD. Mean difference and intraclass correlation coefficient (ICC) with confidence limits were assessed, and calculations of estimated residual refraction of the IOL were analysed using Barrett’s formula.
Results
Sixty-nine eyes from 45 PACD patients were enrolled for the study. Excellent agreement of various parameters was revealed, with ICC (confidence limits) of K1 = 0.953 (0.861–0.979), K2 = 0.950 (0.778–0.98), ACD = 0.932 (0.529–0.978), WTW = 0.775 (0.477–0.888), and LT = 0.947 (0.905–0.97). Mean difference of axial length (AL) was -0.01 ± 0.02 mm with ICC of 1.000. IOL calculation was assessed with Barrett’s formula, and Bland-Altman plot showed excellent agreement in the results of the 2 devices for the IOL power and estimated post-operative residual refraction (EPR).
Conclusions
Mean differences of biometric parameters, obtained with IOL Master700 and Anterion, were small, and ICC showed excellent concordance. No clinical relevance in calculation of IOL power was found, and the two devices appeared to be comparably effective in clinical practice.
Collapse
Affiliation(s)
- Boonsong Wanichwecharungruang
- Department of Ophthalmology, Rajavithi Hospital and Rangsit Medical College, Bangkok, Thailand
- Department of Ophthalmology, Priest Hospital, Bangkok, Thailand
| | | | - Wisakorn Wongwijitsook
- Department of Ophthalmology, Rajavithi Hospital and Rangsit Medical College, Bangkok, Thailand
| | - Kittipong Kongsomboon
- Department of Preventive and Social Medicine, Faculty of Medicine, Srinakharinwirot University, Nakhon Nayok, Thailand
| | - Somporn Chantra
- Department of Ophthalmology, Rajavithi Hospital and Rangsit Medical College, Bangkok, Thailand
- * E-mail:
| |
Collapse
|
7
|
Yildirim TM, Łabuz G, Hammer M, Son HS, Schickhardt SK, Auffarth GU, Khoramnia R. A Novel Approach for Assessing Visual Impairment Caused by Intraocular Lens Opacification: High-Resolution Optical Coherence Tomography. Am J Ophthalmol 2021; 226:108-116. [PMID: 33571474 DOI: 10.1016/j.ajo.2021.02.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 01/16/2021] [Accepted: 02/02/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE To quantify in vitro straylight induced by intraocular lens (IOL) localized opacification using an anterior segment optical coherence tomography (OCT) device. DESIGN Laboratory investigation. METHODS We obtained high-resolution OCT cross-section images of 44 explanted IOLs using a new in vitro application for an anterior segment OCT device, the Anterion (Heidelberg Engineering, Heidelberg, Germany). In 24 cases, the reason for IOL explantation was a centrally localized opacification, the sequela of a secondary ocular surgery. As a control, we used 20 IOLs removed after an IOL (sub-)luxation. Using image analysis, we found a threshold area value representing a metric for the amount of opacification in a region of interest in the IOL's central optic. We used a modified C-Quant straylight meter (Oculus, Wetzlar, Germany) to quantify light scattering. We derived a linear regression from calculating the correlation between the amount of opacification and straylight. RESULTS We visualized different amounts of IOL opacification using the OCT device. The opacified lenses showed a mean threshold area of 6.7% ± 3.3% and mean straylight was 95.1 ± 75.6 deg2/sr. The clear group's mean threshold area was 2.0% ± 0.8% and 5.0 ± 3.4 deg2/sr mean straylight. Straylight correlated statistically significantly with the threshold area, with a correlation coefficient of R2 = 0.80, P < .001. CONCLUSIONS This high-resolution OCT imaging technique can be used to visualize IOL opacities. The amount of opacification correlated well with the straylight induced by the lens. Anterior segment OCT imaging might be used in the future as a tool for predicting the extent of visual impairment and aid clinicians to quantify patients' complaints.
Collapse
|