Chen L, Khamar P, Wang Y, Fu H, Shetty R. Evaluation of Higher-Order Aberrations After the Smooth Incision Lenticular Keratomileusis (SILK TM) Procedure Using the ELITA TM Femtosecond Platform for Correction of Myopic and Astigmatic Refractive Errors. Clin Ophthalmol 2024; 18:2155-2166. [PMID: 39070107 PMCID: PMC11283805 DOI: 10.2147/opth.s466932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Accepted: 07/10/2024] [Indexed: 07/30/2024] Open
Abstract
Purpose To evaluate the changes of higher-order wavefront aberrations following the Smooth Incision Lenticular Keratomileusis (SILKTM) procedure for correction of myopic refractive errors with and without astigmatism, using the ELITATM Femtosecond Platform. Methods This prospective study included 24 eyes that underwent SILK procedure using one ELITA femtosecond laser system for the correction of myopic refractive errors with and without astigmatism. Preoperative and postoperative 1-day, 1-week, 1-month, 3-month, and 9-month eye exams were measured with a commercial wavefront aberrometer (iDESIGN ® Refractive Studio, Johnson & Johnson Surgical Vision, Inc). Wavefront aberrations up to the 6th order Zernike coefficients, including coma Z(3, -1) and Z(3, 1), spherical aberration Z(4, 1), and the wavefront error of all higher-order aberrations (HOAs RMS), were evaluated across a 6 mm pupil. Results The mean manifest refractive spherical equivalent changed from the preoperative refractions -3.82 ± 1.26 D (range -6.00 to -2.25 D) to the postoperative refractions -0.20 ± 0.15 D (range -0.50 to 0.00 D) at the 9-month follow-up. Compared to baseline preoperative HOAs, the mean postoperative HOAs were significantly increased at the 1-day follow-up. On average, at the 9-month postoperative assessment the vertical coma Z(3, -1) was -0.054 ±0.186 µm, horizontal coma Z(3, 1) was 0.016 ± 0.124 µm, spherical aberration Z(4, 0) was 0.046 ± 0.163 µm, and HOAs RMS was 0.363 ± 0.115 µm across a 6 mm pupil. There is no significant difference in the mean HOAs starting at 1-week follow-up for the horizontal coma (P = 0.346) and spherical aberration (P = 0.095). Conclusions The visual outcomes demonstrated that the SILK procedure for refractive lenticule extraction using ELITA femtosecond laser system is effective and predictable for the correction of myopic refractive errors with and without astigmatism. The ELITA femtosecond laser system induced minimal HOAs in surgical eyes following the SILK procedures. These results demonstrate fast corneal recovery starting at 1-week follow-up, and spherical aberration was not induced.
Collapse
Affiliation(s)
- Li Chen
- Johnson & Johnson Surgical Vision, Inc., Milpitas, CA, USA
| | - Pooja Khamar
- Narayana Nethralaya Eye Hospital, Bangalore, India
| | - Ying Wang
- Johnson & Johnson Surgical Vision, Inc., Irvine, CA, USA
| | - Hong Fu
- Johnson & Johnson Surgical Vision, Inc., Milpitas, CA, USA
| | - Rohit Shetty
- Narayana Nethralaya Eye Hospital, Bangalore, India
| |
Collapse
|
2
|
Yoon H, Magnago T, Yeom DJ. Three-Month Clinical Outcomes to Correct Myopia or Myopic Astigmatism Using a Femtosecond Laser for Lenticule Creation With Automated Centration and Cyclotorsion Compensation. J Refract Surg 2024; 40:e30-e41. [PMID: 38190561 DOI: 10.3928/1081597x-20231212-03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
PURPOSE To individually evaluate the clinical outcomes for right and left eyes in the first 3 months after laser-assisted lenticule extraction for myopia and myopic astigmatism with the use of the new ATOS femtosecond laser system (Smart-Sight; SCHWIND eye-tech-solutions). METHODS A total of 331 eyes from 168 patients (166 right eyes and 165 left eyes) consecutively treated with SmartSight lenticule extraction were retrospective analyzed after a 3-month follow-up period. Patients' mean age was 26 ± 6 years (range: 18 to 47 years) and mean preoperative spherical equivalent (SEQ) was -5.07 ± 1.92 diopters [D] (range: -1.50 to -11.25 D) with a mean astigmatism of -1.04 ± 0.85 D (range: 0.00 to -4.00 D). At 3 months of follow-up, visual acuity, SEQ and cylinder, safety index, efficacy index, corneal higher order aberrations, and intraocular pressure (IOP) were analyzed. Furthermore, refractive and visual outcomes were also analyzed for the right and left eyes individually. All lenticule extraction treatments were performed with the SmartSight treatment method of the SCHWIND ATOS femtosecond laser. RESULTS At 3 months after surgery, mean SEQ was -0.12 ± 0.19 D and 98% of eyes were within ±0.50 D of the SEQ. All eyes were within ±1.00 D of the SEQ. Astigmatism of 0.50 D or less was achieved in 99% of eyes. The change in Snellen lines (difference between preoperative corrected distance visual acuity and postoperative uncorrected distance visual acuity) showed a gain of one or more lines in 13% and in 85% of the eyes the same was achieved. There was a loss of one or more lines at 3 months of follow-up in 1.6%. The safety index was 1.03 and efficacy index was 1.02. No significant difference between the right and left eyes was found. CONCLUSIONS The 3-month follow-up data show that SmartSight treatment for correction of myopia and myopic astigmatism with the SCHWIND ATOS is a safe, efficient, and accurate procedure. It provided excellent results in terms of visual recovery, predictability, and higher order aberrations. [J Refract Surg. 2024;40(1):e30-e41.].
Collapse
|
3
|
Gabric I, Bohac M, Gabric K, Arba Mosquera S. First European results of a new refractive lenticular extraction procedure-SmartSight by SCHWIND eye-tech-solutions. Eye (Lond) 2023; 37:3768-3775. [PMID: 37277614 PMCID: PMC10698070 DOI: 10.1038/s41433-023-02601-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 05/05/2023] [Accepted: 05/19/2023] [Indexed: 06/07/2023] Open
Abstract
BACKGROUND To evaluate vision 3 months after SmartSight lenticule extraction treatments. DESIGN Case series. METHODS This case series of patients were treated at Specialty Eye Hospital Svjetlost in Zagreb, Croatia. Sixty eyes of 31 patients consecutively treated with SmartSight lenticule extraction were assessed. The mean age of the patients was 33 ± 6 years (range 23-45 years) at the time of treatment with a mean spherical equivalent refraction of -5.10 ± 1.35 D and mean astigmatism of 0.46 ± 0.36 D. Monocular corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA) were assessed pre- and post-operatively. Ocular and corneal wavefront aberrations have been postoperatively compared to the preoperative baseline values. Changes in ocular wavefront refraction, as well as changes in keratometric readings are reported. RESULTS At 3 months post-operatively, mean UDVA was 20/20 ± 2. Spherical equivalent showed a low myopic residual refraction of -0.37 ± 0.58 D with refractive astigmatism of 0.46 ± 0.26 D postoperatively. There was a slight improvement of 0.1 Snellen lines at 3-months follow-up. Compared to the preoperative status, ocular aberrations (at 6 mm diameter) did not change at 3 months follow-up; whereas corneal aberrations increased (+0.22 ± 0.21 µm for coma; +0.17 ± 0.19 µm for spherical aberration; and +0.32 ± 0.26 µm for HOA-RMS). The same correction was determined using changes in ocular wavefront refraction, as well as changes in keratometric readings. CONCLUSION Lenticule extraction after SmartSight is safe and efficacious in the first 3 months postoperatively. The post-operative outcomes indicate improvements in vision.
Collapse
Affiliation(s)
- Ivan Gabric
- Specialty Eye Hospital Svjetlost, School of Medicine University of Rijeka, Zagreb, Croatia
| | - Maja Bohac
- Specialty Eye Hospital Svjetlost, School of Medicine University of Rijeka, Zagreb, Croatia.
| | - Kresimir Gabric
- Specialty Eye Hospital Svjetlost, School of Medicine University of Rijeka, Zagreb, Croatia
| | | |
Collapse
|
4
|
Pradhan KR, Arba Mosquera S. Comparing high and low energy outcomes on day one for SmartSight myopic-astigmatism treatments with the SCHWIND ATOS: a retrospective case series. BMC Ophthalmol 2023; 23:328. [PMID: 37464345 DOI: 10.1186/s12886-023-03076-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 07/12/2023] [Indexed: 07/20/2023] Open
Abstract
BACKGROUND Impact of low energy asymmetric spacings vs. high energy symmetric spacings on the immediate/early (postoperative day 1 (POD1)) outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS The first 112 eyes of 56 patients consecutively treated using low energy asymmetric spacings (Group A; Study group) were compared at POD1 to the last 112 eyes of 56 patients consecutively treated using high energy symmetric spacings (Group S; Controls). Mean age of the patients was 28 ± 5 years with a mean spherical equivalent of -4.41 ± 1.76 diopters (D) and a mean magnitude of refractive astigmatism of 0.89 ± 0.82 D. RESULTS Laser Energy was -25 ± 1nJ lower for asymmetric treatments (p < .0001); Spot and Track distances were + 0.7 ± 0.1 µm larger and -0.8 ± 0.1 µm tighter for asymmetric treatments, respectively (p < .0001 for both). At POD1, astigmatism was -0.08 ± 0.02D lower for asymmetric treatments (p < .0003); uncorrected and corrected visual acuities (UDVA and CDVA, respectively) were -0.03 ± 0.01logMAR better for asymmetric treatments (p < .0007); differences between postop UDVA and preop CDVA along with change in CDVA were + 0.3 ± 0.1lines better for asymmetric treatments (p < .0003). CONCLUSIONS Lenticule extraction treatment using SmartSight is safe and efficacious already at POD1. Findings suggest that low energy asymmetric spacings may further improve the immediate and short-term outcomes of SmartSight lenticule extraction in the treatment of myopic astigmatism compared to conventional settings (high energy symmetric spacings).
Collapse
Affiliation(s)
- Kishore Raj Pradhan
- Matrika Eye Center, Dhunge Dhara Marg, Ward number 9, Kathmandu, 44600, Nepal
| | | |
Collapse
|
5
|
Pradhan KR, Arba Mosquera S. Twelve-month outcomes of a new refractive lenticular extraction procedure. JOURNAL OF OPTOMETRY 2023; 16:30-41. [PMID: 34949535 PMCID: PMC9811368 DOI: 10.1016/j.optom.2021.11.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 11/02/2021] [Accepted: 11/11/2021] [Indexed: 06/07/2023]
Abstract
BACKGROUND To evaluate the 12-month refractive and visual outcomes of Small Incision Guided Human-cornea Treatment (SmartSight®, SCHWIND eye-tech-solutions, Kleinostheim, Germany) in the treatment of myopia corrections with low to moderate astigmatism with the use of a new femtosecond laser system. METHODS 221 eyes of 114 patients consecutively treated with SmartSight lenticule extraction were assessed. The mean age of the patients was 28±6 years at the time of treatment with a mean spherical equivalent refraction of -6.26±2.17D and mean astigmatism of 0.92±0.68D. Monocular corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA) were assessed pre- and post-operatively. Refractive changes have been determined in terms of changes in refraction, as well as changes in keratometric readings. The changes in central epithelial thickness have been determined. RESULTS At twelve months post-operatively, mean UDVA was 20/21±2. Spherical equivalent showed a residual refraction of +0.48±0.31D with refractive astigmatism of 0.13±0.18D postoperatively. There was a slight decrease of -0.1 Snellen lines at 12-months follow-up. The same correction was determined using changes in refraction, as well as changes in keratometric readings. The central epithelial thickness increased by +3±2µm. Spherical equivalent correction within ±0.50D was achieved in 199 eyes (90%), and cylindrical correction in 221 (100%). Preoperative corrected distance visual acuity (CDVA) was 20/20 or better in 213 eyes (96%), and postoperative uncorrected (UDVA) was 20/20 or better in 205 eyes (93%). No eye had lost two or more Snellen lines of CDVA. CONCLUSIONS Myopic astigmatism correction with SmartSight provided good results for efficacy, safety, predictability, and visual outcomes at the twelve months of follow up. The central epithelial thickness barely increased by 3±2µm.
Collapse
Affiliation(s)
- Kishore Raj Pradhan
- Matrika Eye Center, Dhunge Dhara Marg, Ward number 9, Kathmandu 44600, Nepal.
| | | |
Collapse
|
6
|
Yan Q, Han B, Ma ZC. Femtosecond Laser-Assisted Ophthalmic Surgery: From Laser Fundamentals to Clinical Applications. MICROMACHINES 2022; 13:1653. [PMID: 36296006 PMCID: PMC9611681 DOI: 10.3390/mi13101653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 09/19/2022] [Accepted: 09/28/2022] [Indexed: 06/16/2023]
Abstract
Femtosecond laser (FSL) technology has created an evolution in ophthalmic surgery in the last few decades. With the advantage of high precision, accuracy, and safety, FSLs have helped surgeons overcome surgical limits in refractive surgery, corneal surgery, and cataract surgery. They also open new avenues in ophthalmic areas that are not yet explored. This review focuses on the fundamentals of FSLs, the advantages in interaction between FSLs and tissues, and typical clinical applications of FSLs in ophthalmology. With the rapid progress that has been made in the state of the art research on FSL technologies, their applications in ophthalmic surgery may soon undergo a booming development.
Collapse
Affiliation(s)
- Quan Yan
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China
- National Clinical Research Center for Eye Diseases, Shanghai 200080, China
- Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai 200080, China
| | - Bing Han
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Zhuo-Chen Ma
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
7
|
Ex-vivo study on the surface quality of corneal lenticule and stroma after low energy femtosecond laser lenticule extraction. Sci Rep 2022; 12:10034. [PMID: 35705567 PMCID: PMC9200215 DOI: 10.1038/s41598-022-13468-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 05/24/2022] [Indexed: 11/26/2022] Open
Abstract
This study aimed to assess the surface quality of cap, stroma and lenticular surfaces created using low-energy femtosecond laser lenticule extraction (Ziemer FEMTO LDV Z8). Twenty-four porcine eyes were divided into four groups (n = 6 each): two with optimal laser power (32%) with posterior curvature equivalent to a spherical correction of -2D and -5D, respectively and the other two with high power (64%) with spherical correction of -2D and -5D respectively. Samples were analysed using scanning electron microscopy (SEM). Surface morphology was evaluated using a standard scoring system; surface relief, surface regularity, extent and position of irregularities were graded by four independent clinicians. Eyes with 32% power and -2D correction had significantly less size of the irregular area than those with -5D; however, no significant difference was found between the two groups with 64% power. When comparing eyes with -2D correction, the size of the irregular area was lesser with 32% power. Surface relief was lesser with -5D correction with 32% power than 64% power. Low-energy femtosecond laser lenticule extraction (Ziemer FEMTO LDV Z8) produces good surface quality results. There is a tendency for smoother surface stromal quality with lower power settings than a higher power.
Collapse
|
8
|
Lwowski C, Voigt A, Van Keer K, Kohnen T. Corneal Lenticule Creation Using a New Solid-State Femtosecond Laser Measured by Spectral Domain OCT in a Porcine Eye Model. Transl Vis Sci Technol 2022; 11:20. [PMID: 35731540 PMCID: PMC9233285 DOI: 10.1167/tvst.11.6.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To determine the accuracy and precision of corneal lenticule creation with a new solid-state femtosecond laser in a porcine eye model. Methods Corneal lenticule creation was performed using a new solid-state femtosecond laser on 60 porcine eyes with 10 subgroups. Optical coherence tomography images were acquired immediately after laser treatment. Cap thickness (CT), cap diameter (CD), and lenticule thickness (LT) were measured manually by three independent readers. Additionally, CT and LT were measured by an automated algorithm (aLT, aCT). Results Measured LT was significantly greater than the intended LT (average difference 14.3 ± 5.6 µm, P < 0.001). aLT was closer but still significantly different from the intended LT (-2.9 ± 5.8 µm, P < 0.001). Measured CT showed no significant difference from the intended CT (2.6 ± 13.3, P = 0.145). aCT was significantly smaller compared to the intended CT (-9.6 ± 13.6, P < 0.001). Measured CD was significantly smaller compared to the intended CD (-0.21 ± 0.20 mm, P < 0.001). All lenticules were cut as planned with no laser-related complications. Conclusions This new solid-state femtosecond laser used in our trial provides corneal lenticule creation in a porcine eye model comparable to other established systems. However, measuring those lenticules in the provided setting seems too challenging even when using semiautomated algorithms, which seems to be due to the experimental setting of the trial. Translational Relevance This trial shows the precision and repeatability of corneal cuts performed by a new femtosecond laser that could translate to refractive corneal lenticule surgery.
Collapse
Affiliation(s)
- Christoph Lwowski
- Department of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| | - Anna Voigt
- Department of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| | - Karel Van Keer
- Department of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany.,Department of Ophthalmology, University Hospitals Leuven, Leuven, Belgium
| | - Thomas Kohnen
- Department of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| |
Collapse
|
9
|
Arba-Mosquera S, Naubereit P, Sobutas S, Verma S. Analytical optimization of the cutting efficiency for generic cavitation bubbles. BIOMEDICAL OPTICS EXPRESS 2021; 12:3819-3835. [PMID: 34457382 PMCID: PMC8367260 DOI: 10.1364/boe.425895] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 06/01/2021] [Accepted: 06/01/2021] [Indexed: 06/07/2023]
Abstract
A theoretical method to determine the optimum laser parameters for maximizing the cutting efficiency for different materials (in particular human cornea) is proposed. The model is simple and reduced to laser beam characteristics and cavitation properties. The model further provides a method to convert energy fluctuations during the cutting process to equivalent deviations in the cavitation bubbles. The proposed model can be used for calibration, verification and validation purposes of laser systems used for cutting processes at relatively low cost and may improve the quality of the results.
Collapse
Affiliation(s)
| | | | | | - Shwetabh Verma
- SCHWIND eye-tech-solutions, Kleinostheim, D- 63801, Germany
| |
Collapse
|
10
|
Pradhan KR, Arba-Mosquera S. Three-Month Outcomes of Myopic Astigmatism Correction With Small Incision Guided Human Cornea Treatment. J Refract Surg 2021; 37:304-311. [PMID: 34044692 DOI: 10.3928/1081597x-20210210-02] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate refractive and visual outcomes of small incision guided human cornea treatment (SmartSight; SCHWIND eye-tech-solutions) in the treatment of myopic astigmatism with the use of a new femtosecond laser system. METHODS This retrospective, observational case series study included 104 eyes of 56 patients who underwent SmartSight to correct myopic astigmatism and completed the 3-month follow-up. Procedures were performed with a SCHWIND ATOS femtosecond laser. RESULTS Preoperatively, mean manifest spherical equivalent refraction was -6.12 ± 1.99 diopters (D) (range: -3.00 to -11.50 D) and astigmatism was 1.02 ± 0.56 D (range: 0.25 to 2.75 D). Three months postoperatively, it was +0.47 ± 0.32 D (range: -0.75 to +1.00 D) and 0.27± 0.22 D (range: 0.00 to 0.75 D), respectively (both P < .05). Spherical equivalent correction within ±0.50 D was achieved in 62 eyes (60%), and cylindrical correction in 90 eyes (87%). Preoperative corrected distance visual acuity (CDVA) was 20/20 or better in 94 eyes (90%) and postoperative uncorrected distance visual acuity was 20/20 or better in 96 eyes (92%). No eye lost two or more Snellen lines of CDVA. CONCLUSIONS Myopic astigmatism correction with Smart-Sight provided good results for efficacy, safety, predictability, and visual outcomes in the first 3 months of follow-up. [J Refract Surg. 2021;37(5):304-311.].
Collapse
|
11
|
Fuest M, Mehta JS. Advances in refractive corneal lenticule extraction. Taiwan J Ophthalmol 2021; 11:113-121. [PMID: 34295616 PMCID: PMC8259523 DOI: 10.4103/tjo.tjo_12_21] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 03/16/2021] [Indexed: 01/31/2023] Open
Abstract
Refractive errors are the leading cause of reversible visual impairment worldwide. In addition to the desired spectacle independence, refractive procedures can improve quality of life, working ability, and daily working performance. Refractive corneal lenticule extraction (RCLE) is a relatively new technique, dependent only on a femtosecond laser (FS). This leads to potential benefits over laser-assisted in situ keratomileusis (LASIK) including a quicker recovery of dry eye disease, a larger functional optical zone, and no flap-related complications. SMILE, available with the VisuMax FS (Carl Zeiss Meditec AG, Jena, Germany), is the most established RCLE application, offering visual and refractive outcomes comparable to LASIK. SmartSight (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany) and CLEAR (Ziemer Ophthalmic Systems AG, Port, Switzerland) are two new RCLE applications that received Conformité Européenne (CE) approval in 2020. In this article, we review refractive and visual outcomes, advantages, and disadvantages of RCLE and also report on the latest advances in RCLE systems.
Collapse
Affiliation(s)
- Matthias Fuest
- Department of Ophthalmology, RWTH Aachen University, Aachen, Germany
| | - Jodhbir S Mehta
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore.,Singapore National Eye Centre, Singapore.,Eye-Academic Clinical Program, Duke-National University of Singapore Graduate Medical School, Singapore.,School of Material Science and Engineering, Nanyang Technological University, Singapore
| |