Termote K, Van Schoor R, Krolo I, Oellerich S, Cools W, Delbeke H, Ni Dhubhghaill S. Combination of a monofocal and one type of extended depth-of-focus (zonal refractive) intraocular lens (COMEDI) in bilateral cataract surgery protocol: a monocentric, randomised, parallel group trial in cataract surgery. BMJ Open Ophthalmol 2024; 9:e001572. [PMID: 39103234 PMCID: PMC11308891 DOI: 10.1136/bmjophth-2023-001572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Accepted: 06/28/2024] [Indexed: 08/07/2024] Open
Abstract
INTRODUCTION Modern intraocular lens (IOL) designs for cataract treatment can be broadly classified into three focal range categories; monofocal, extended depth-of-focus (EDOF) and multifocal IOLs.Monofocal IOLs allow spectacle independence for one focus, typically distance. In contrast, EDOF IOLs provide a greater range of vision, extending spectacle independence to intermediate distance, while multifocal IOLs enable spectacle independence at all distances with the drawback of positive dysphotopsias and reduced contrast perception.EDOF lenses are an attractive compromise with fewer dysphotopic side effects than multifocals. The purpose of this study is to assess whether implanting an EDOF IOL in the second eye of a patient who received a monofocal IOL in the first eye can improve spectacle independence while maintaining the same optical quality as bilateral monofocal IOL implantation. METHODS AND ANALYSIS This study compares combined monofocal and EDOF IOL implantation versus bilateral monofocal IOL implantation in terms of clinical and patient-reported outcomes in a monocentric, randomised, patient-masked and assessor-masked, parallel group trial in 88 bilateral cataract patients. The primary outcome measure is binocular photopic distance corrected intermediate visual acuity. The secondary outcome measures include (un)corrected distance and near visual acuity, reading speed at intermediate distance, quality of visual function assessments, patient-reported spectacle independence, contrast sensitivity, aberrometry, stereopsis and straylight measurement at the 3-month follow-up. ETHICS AND DISSEMINATION The protocol was approved by the ethical committee of the University Hospital of Brussels (BUN 23219_EDOF). TRIAL REGISTRATION NUMBER NCT06002399.
Collapse
Affiliation(s)
- Karolien Termote
- Department of Ophthalmology, University Hospital Brussels, Jette, Belgium
- Department of Medicine and Pharmacology, Vrije Universiteit Brussel, Brussels, Belgium
| | - Roger Van Schoor
- Department of Ophthalmology, University Hospital Brussels, Jette, Belgium
- Department of Medicine and Pharmacology, Vrije Universiteit Brussel, Brussels, Belgium
| | - Iva Krolo
- Department of Ophthalmology, University Hospital Brussels, Jette, Belgium
- Department of Medicine and Pharmacology, Vrije Universiteit Brussel, Brussels, Belgium
| | - Silke Oellerich
- Department of Ophthalmology, University Hospital Brussels, Jette, Belgium
- Department of Medicine and Pharmacology, Vrije Universiteit Brussel, Brussels, Belgium
| | - Wilfried Cools
- Interfaculty Center for Data Processing and Statistics, Vrije Universiteit Brussel, Brussels, Belgium
| | - Heleen Delbeke
- Department of Ophthalmology, University Hospitals Leuven, Leuven, Belgium
- Department of Neurosciences, Research Group Ophthalmology, Biomedical Sciences Group, KU Leuven, Leuven, Belgium
| | - Sorcha Ni Dhubhghaill
- Department of Ophthalmology, University Hospital Brussels, Jette, Belgium
- Department of Medicine and Pharmacology, Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
2
|
Nguyen MTD, Yuan PHS, Bachour K, Sierra MCA, Durr GM. Visual outcomes and rotational stability of a new non-diffractive extended-vision toric intraocular lens. CANADIAN JOURNAL OF OPHTHALMOLOGY 2024; 59:234-240. [PMID: 37321557 DOI: 10.1016/j.jcjo.2023.05.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 05/11/2023] [Accepted: 05/19/2023] [Indexed: 06/17/2023]
Abstract
OBJECTIVE To evaluate visual outcomes and intraocular lens (IOL) rotational stability of patients undergoing immediate sequential bilateral cataract surgery with a non-diffractive extended-depth-of-focus toric IOL. DESIGN Non-comparative single-centre cohort study. PARTICIPANTS Twenty patients (40 eyes) with significant cataracts and corneal astigmatism who underwent immediate sequential bilateral cataract surgery with the AcrySof IQ Vivity Extended Vision Lens (Alcon Laboratories Inc, Fort Worth, Tex.). METHODS Binocular uncorrected visual acuities (UCVA) and monocular best-corrected visual acuities (BCVA) were assessed at distance (6 m), intermediate (66 cm), and near (40 cm) postoperatively at 1 week and 3 months. The rotational stability of each IOL was assessed at 1 day, 1 week, and 3 months postoperatively. A validated questionnaire (Questionnaire for Visual Disturbances [QUVID]) was used for patient-reported subjective visual disturbances preoperatively at a 3-month follow-up. RESULTS Binocular distance, intermediate, and near UCVAs (mean ± SD) were 0.00 ± 0.16, 0.09 ± 0.08, and 0.14 ± 0.11 logMAR at 1 week and 0.01 ± 0.06, 0.08 ± 0.08, and 0.14 ± 0.07 logMAR at 3 months postoperatively, respectively. Distance monocular BCVA improved from 0.22 ± 0.23 logMAR preoperatively to 0.02 ± 0.06 logMAR at 3 months. Monocular BCVAs at 3 months were 0.08 ± 0.08 logMAR at intermediate distance and 0.05 ± 0.08 logMAR at near distance. IOL rotation from the intended placement axis was 2.5 ± 1.7 degrees at 1 week and 1.7 ± 1.7 degrees at 3 months postoperatively. CONCLUSIONS The AcrySof IQ Vivity Extended Vision IOL achieved good UCVAs and BCVAs for distance, intermediate, and near vision. This IOL also provided excellent rotational stability for astigmatism correction.
Collapse
Affiliation(s)
| | - Po Hsiang Shawn Yuan
- Department of Ophthalmology, University of Montreal Hospital Centre (CHUM), Montreal, QC.
| | - Kenan Bachour
- Department of Ophthalmology, University of Montreal, Montreal, QC
| | | | - Georges M Durr
- Department of Ophthalmology, University of Montreal, Montreal, QC; Department of Ophthalmology, University of Montreal Hospital Centre (CHUM), Montreal, QC
| |
Collapse
|
3
|
Won YK, Choi SH, Chung TY, Lim DH. Clinical Outcomes after Bilateral Implantation of a Wavefront-Shaping Extended Depth of Focus (EDOF) IOL with Mini-Monovision. J Clin Med 2024; 13:3225. [PMID: 38892936 PMCID: PMC11172505 DOI: 10.3390/jcm13113225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 05/12/2024] [Accepted: 05/28/2024] [Indexed: 06/21/2024] Open
Abstract
Background: To compare the visual outcomes and optical quality of patients who underwent bilateral implantation of EDOF (AcrySof® IQ Vivity IOL, DFT015) for mini-monovision, trifocal (AcrySof® IQ PanOptix, TNFT00), or monofocal (AcrySof® IQ IOL, SN60WF) IOL. Methods: The monocular-corrected and uncorrected distance visual acuities (CDVA and UDVA, respectively) were evaluated postoperatively at 1 and 3 months. The binocular visual acuity by distance, the binocular defocus curve, contrast sensitivity, and patient satisfaction were examined 3 months postoperatively. All patients were asked to complete questionnaires regarding their satisfaction, visual symptoms, and spectacle dependency. Results: This study included 178 eyes from 89 patients. The postoperative binocular UDVA did not differ significantly among the three groups. In the defocus curve, the Vivity group showed better visual acuity over a range of far and intermediate (60 cm) than the other two IOLs groups. In near-vision, the PanOptix group showed the best near-vision, and the Vivity group showed significantly better vision than the IQ group. The Vivity group showed contrast sensitivity and optical quality comparable to the IQ group. Conclusions: The bilateral implantation of AcrySof® IQ Vivity IOL with the mini-monovision approach provided excellent distance and intermediate visual acuity with good near-vision, resulting in high satisfaction.
Collapse
Affiliation(s)
- Yeo Kyoung Won
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
| | - Sung Ho Choi
- First Samsung Eye Clinic, Seoul 06621, Republic of Korea
| | - Tae-Young Chung
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
- Renew Seoul Eye Center, Seoul 06181, Republic of Korea
| | - Dong Hui Lim
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
- Samsung Advanced Institute for Health Sciences & Technology, Sungkyunkwan University, Seoul 06351, Republic of Korea
| |
Collapse
|
4
|
Black DA, Bala C, Alarcon A, Vilupuru S. Tolerance to refractive error with a new extended depth of focus intraocular lens. Eye (Lond) 2024; 38:15-20. [PMID: 38580742 PMCID: PMC11080636 DOI: 10.1038/s41433-024-03040-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 03/12/2024] [Accepted: 03/15/2024] [Indexed: 04/07/2024] Open
Abstract
PURPOSE To evaluate the tolerance to refractive errors of a new purely refractive extended depth of focus (EDF) intraocular lens (IOL) using preclinical and clinical metrics. METHODS Preclinical evaluation included computer simulations of visual acuity (sVA) and dysphotopsia profile of different IOL designs (refractive EDF, diffractive EDF, multifocal, standard, and enhanced monofocals) using an appropriate eye model with and without ±0.50 D defocus and/or +0.75 D of astigmatism. Patients bilaterally implanted with a refractive EDF (Model ZEN00V) or an enhanced monofocal (Model ICB00) IOL from a prospective, randomized study were included. At the 6-month postoperative visit, uncorrected and corrected distance vision (UDVA and CDVA), visual symptoms, satisfaction and dependency on glasses were evaluated in a subgroup of patients with absolute residual refractive error of >0.25 D in one or both eyes. RESULTS In the presence of defocus and astigmatism, sVA was comparable for all except the multifocal IOL design. The refractive EDF was more tolerant to myopic outcomes and maintained a monofocal-like dysphotopsia profile with defocus. Binocular logMAR UDVA was -0.03 ± 0.08 for ZEN00V and -0.02 ± 0.11 for ICB00. 100% ZEN00V and 97% ICB00 patients did not need glasses and were satisfied with their distance vision. Monocular CDVA, contrast sensitivity and visual symptoms were also similar between both groups. CONCLUSIONS The clinical outcomes of the refractive EDF IOL demonstrated high quality distance vision and dysphotopsia comparable to a monofocal IOL, even in the presence of refractive error, thus matching the design expectations of the EDF IOL.
Collapse
Affiliation(s)
| | | | - Aixa Alarcon
- Johnson and Johnson MedTech, Groningen, The Netherlands
| | | |
Collapse
|
5
|
Alarcon A, Del Aguila Carrasco A, Gounou F, Weeber H, Cánovas C, Piers P. Optical and clinical simulated performance of a new refractive extended depth of focus intraocular lens. Eye (Lond) 2024; 38:4-8. [PMID: 38580743 PMCID: PMC11080621 DOI: 10.1038/s41433-024-03041-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 03/14/2024] [Accepted: 03/15/2024] [Indexed: 04/07/2024] Open
Abstract
OBJECTIVES The purpose of this study is to evaluate the optical and expected clinical performance of a new refractive Extended Depth of Focus (EDF) intraocular lens (IOL) designed to maintain a monofocal-like dysphotopsia profile. METHODS Simulated visual acuity (sVA) with varying defocus was calculated using the area under the Modulation Transfer Function measured in an average eye model and from computer simulations in eye models with corneal higher-order aberrations. Tolerance to defocus was evaluated using computer simulations of the uncorrected distance sVA under defocus. To evaluate the dysphotopsia profile, halo pictures obtained using an IOL-telescope, as well as simulated images in a realistic eye model under defocus were assessed. The results of the refractive EDF were compared to those of a diffractive EDF of the same platform. RESULTS The refractive EDF IOL provides similar range of vision to the diffractive EDF IOL with the same distance, and similar intermediate and near sVA. The refractive EDF IOL provides the same tolerance to hyperopia as the diffractive EDF but more tolerance to myopia. Halo pictures and simulations showed that the refractive EDF provides comparable dysphotopsia profile to the monofocal IOL and better than the diffractive EDF. CONCLUSIONS The results of this preclinical study in clinically relevant conditions show that the new refractive EDF IOL is expected to provide similar range of vision to the diffractive IOL of the same platform and higher tolerance to refractive errors. The refractive EDF provides a dysphotopsia profile that is better than the diffractive EDF and comparable to that of the monofocal IOL, also in the presence of residual refractive errors.
Collapse
Affiliation(s)
- Aixa Alarcon
- Johnson and Johnson Vision Van Swietenlaan 5, Groningen, 9728 NX, The Netherlands.
| | | | - Franck Gounou
- Johnson and Johnson Vision Van Swietenlaan 5, Groningen, 9728 NX, The Netherlands
| | - Henk Weeber
- Johnson and Johnson Vision Van Swietenlaan 5, Groningen, 9728 NX, The Netherlands
| | - Carmen Cánovas
- Johnson and Johnson Vision Van Swietenlaan 5, Groningen, 9728 NX, The Netherlands
| | - Patricia Piers
- Johnson and Johnson Vision Van Swietenlaan 5, Groningen, 9728 NX, The Netherlands
| |
Collapse
|
6
|
Li J, Sun B, Zhang Y, Hao Y, Wang Z, Liu C, Jiang S. Comparative efficacy and safety of all kinds of intraocular lenses in presbyopia-correcting cataract surgery: a systematic review and meta-analysis. BMC Ophthalmol 2024; 24:172. [PMID: 38627651 PMCID: PMC11020619 DOI: 10.1186/s12886-024-03446-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 04/10/2024] [Indexed: 04/19/2024] Open
Abstract
PURPOSE To assess the efficacy and safety of various intraocular lenses (IOLs), including standard monofocal, bifocal, trifocal, extended depth of focus (EDOF), and enhanced monofocal IOLs, post-cataract surgery through a network meta-analysis. METHODS A systematic search of PubMed, Cochrane Library, and Web of Science was conducted to identify relevant studies from the past 5 years. Parameters such as binocular visual acuities, spectacle independence, contrast sensitivity (CS), and optical quality were used to evaluate efficacy and safety. Data from the selected studies were analyzed using Review Manager 5.4 and STATA 17.0 software. RESULTS Twenty-eight Randomized Controlled Trials (RCTs) comprising 2465 subjects were included. Trifocal IOLs exhibited superior uncorrected near visual acuity (UNVA) compared to monofocal IOLs (MD: -0.35; 95% CI: -0.48, -0.22). Both trifocal (AcrySof IQ PanOptix IOLs group MD: -0.13; 95% CI: -0.21, -0.06) and EDOF IOLs (MD: -0.13; 95% CI: -0.17, -0.09) showed better uncorrected intermediate visual acuity (UIVA) than monofocal IOLs. Trifocal IOLs ranked highest in spectacle independence at various distances (AT LISAtri 839MP group: SUCRA 97.5% for distance, 80.7% for intermediate; AcrySof IQ PanOptix group: SUCRA 83.0% for near). CONCLUSIONS For cataract patients who want to treat presbyopia, trifocal IOLs demonstrated better visual acuity and spectacle independence at near distances. Different types of trifocal IOL characteristics differ. EDOF and enhanced monofocal IOLs have improved visual quality at intermediate distances.Therefore, It is very important to select the appropriate IOLs based on the lens characteristics and patient needs.
Collapse
Affiliation(s)
- Jinyu Li
- Department of Ophthalmology, Yantai Affiliated Hospital of Binzhou Medical University, Binzhou Medical University, Jinbu Street, Muping area, Yantai, Shandong Province, 264000, China
| | - Bin Sun
- Department of Ophthalmology, Yantai Affiliated Hospital of Binzhou Medical University, Binzhou Medical University, Jinbu Street, Muping area, Yantai, Shandong Province, 264000, China
| | - Yuexin Zhang
- Department of Ophthalmology, Yantai Affiliated Hospital of Binzhou Medical University, Binzhou Medical University, Jinbu Street, Muping area, Yantai, Shandong Province, 264000, China
| | - Yansong Hao
- Department of Ophthalmology, Yantai Affiliated Hospital of Binzhou Medical University, Binzhou Medical University, Jinbu Street, Muping area, Yantai, Shandong Province, 264000, China
| | - Ze Wang
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shi Jiazhuang, 050200, China
| | - Chengjiang Liu
- Department of General Medicine, Affiliated Anqing First People's Hospital of Anhui Medical University, Anhui, 246000, China
| | - Shanhao Jiang
- Department of Ophthalmology, Yantai Affiliated Hospital of Binzhou Medical University, Binzhou Medical University, Jinbu Street, Muping area, Yantai, Shandong Province, 264000, China.
| |
Collapse
|
7
|
Garzón N, Gómez-Pedrero JA, Albarrán-Diego C, Fernández-Núñez S, Villanueva Gómez-Chacón S, García-Montero M. Optical power profiles and aberrations of a non-diffractive wavefront-shaping extended depth of focus intraocular lens. Graefes Arch Clin Exp Ophthalmol 2024:10.1007/s00417-024-06469-y. [PMID: 38597962 DOI: 10.1007/s00417-024-06469-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/28/2024] [Accepted: 03/27/2024] [Indexed: 04/11/2024] Open
Abstract
PURPOSE This study is to evaluate the optical characteristics of a non-diffractive wavefront-shaping intraocular lens which incorporates surface refractive modifications for shaping the wavefront in order to achieve extended depth of focus (EDoF) and to assess whether the nominal power of this IOL influences the attainable add power. METHODS A commercially available optical bench NIMO TR1504 device (LAMBDA-X, Nivelles, Belgium) was employed to obtain full optical characterization of three non-diffractive EDoF intraocular lenses with + 10 D, + 20 D, and + 30 D powers. After NIMO measurements, data were computed using a custom-made MATLAB program (Mathworks, Inc., Natick, MA, USA) to evaluate the optical quality functions, such as the point spread function (PSF), wavefront profiles, and modulation transfer function (MTF) for two pupil sizes: 3 mm and 4.0 mm. RESULTS The non-diffractive EDoF intraocular lens showed a central serrated power profile behavior with additions of + 2.00 to + 2.50 D over the nominal power. Higher order aberrations were found to be driven mainly by the spherical aberration, with almost null comatic influence. Optical quality metrics showed good values, better for a 3 mm pupil compared to a 4.5 mm one, as expected. The three IOL powers tested showed a very similar behavior in terms of power and aberrometric profiles, with minimal to null differences related to the nominal power. CONCLUSION The non-diffractive wavefront-shaping EDoF intraocular lens achieves a near addition up to + 2.50 D aiming for an extended range of vision, almost independently of the base power.
Collapse
Affiliation(s)
- Nuria Garzón
- Dpto. de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, 28037, Madrid, Spain
| | | | - César Albarrán-Diego
- Dpto. de Óptica y Optometría y Ciencias de La Visión, Universitat de València, Doctor Moliner 50, Burjassot, 46100, Valencia, Spain.
| | - Sara Fernández-Núñez
- Dpto. de Óptica, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, 28037, Madrid, Spain
| | | | - María García-Montero
- Dpto. de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, 28037, Madrid, Spain
| |
Collapse
|
8
|
Pastor-Pascual F, Orts-Vila P, Tañá-Sanz P, Tañá-Sanz S, Ruiz-Mesa R, Tañá-Rivero P. Non-diffractive, toric, extended depth-of-focus intraocular lenses in eyes with low corneal astigmatism. EYE AND VISION (LONDON, ENGLAND) 2024; 11:14. [PMID: 38556883 PMCID: PMC10983649 DOI: 10.1186/s40662-024-00380-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 03/07/2024] [Indexed: 04/02/2024]
Abstract
BACKGROUND To assess clinical outcomes after implanting toric, extended-depth-of-focus intraocular lenses (IOLs) to correct low corneal astigmatism in eyes with cataracts. METHODS 47 eyes were implanted with the AcrySof IQ Vivity Toric DFT215 IOL. Main outcome measures were refractive error, monocular uncorrected and corrected distance (UDVA/CDVA), uncorrected and distance-corrected intermediate (UIVA/DCIVA), and uncorrected near and distance-corrected near (UNVA/DCNVA) visual acuities, monocular defocus curve, rotational stability, and IOLSAT and QUVID questionnaires. Patients were assessed at 3 months postsurgery. RESULTS All eyes had a postoperative spherical equivalent (SE) within ± 0.50 D and 97.87% (n = 46) had a refractive cylinder ≤ 0.50 D. The mean SE and refractive cylinder were - 0.10 ± 0.17 D and - 0.16 ± 0.24 D, respectively. The CDVA was ≥ 20/25 and ≥ 20/32 in 95.74% (n = 45) and 97.87% (n = 46) of eyes, respectively. The DCIVA was ≥ 20/32 in 85.11% (n = 40) of eyes and the DCNVA was ≥ 20/40 in 74.47% (n = 35). The mean values of CDVA, DCIVA, and DCNVA were - 0.02 ± 0.08, 0.14 ± 0.09, and 0.23 ± 0.12 logMAR, respectively. The defocus curve revealed good visual acuity at far and intermediate distances with a depth-of-focus of about 1.75 D. IOL rotation was 0.74 ± 1.13 degrees and all eyes had a rotation of less than 5 degrees. Patients reported either good or very good postoperative vision without eyeglasses under bright-light-conditions at distance (87.80%, 36/41) and intermediate distance (92.68%, 38/41). Between about 63.83%-72.34% (30-34) of patients reported no starburst, halos, or glare, or if experienced, were not bothersome. CONCLUSIONS The Vivity toric IOL implanted in eyes with low-astigmatism provides accurate refractive outcomes, good visual acuity at different distances and excellent rotational stability. Trial Registration The study was registered with the German Clinical Trials Register (DRKS00030579).
Collapse
|
9
|
Thananjeyan AL, Siu A, Jennings A, Bala C. Extended Depth-of-Focus Intraocular Lens Implantation in Patients with Age-Related Macular Degeneration: A Pilot Study. Clin Ophthalmol 2024; 18:451-458. [PMID: 38371465 PMCID: PMC10874221 DOI: 10.2147/opth.s442931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Accepted: 12/27/2023] [Indexed: 02/20/2024] Open
Abstract
Purpose To assess visual outcomes of the implantation of a non-diffractive extended depth of focus (EDOF) intraocular lens (IOL) in patients with age-related macular degeneration (AMD). Setting Ophthalmology practice, Sydney, Australia. Design Retrospective chart review. Methods Patients with AMD undergoing cataract surgery and receiving non-diffractive EDOF AcrySof IQ Vivity IOL implantation over a 2-year period were identified. Corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA; 50 cm), contrast sensitivity, central foveal thickness, VF-14 questionnaire results, and quality of life where available were analyzed. Results A total of 28 sequential patients (51 eyes) were included in this pilot study (46% male, mean age 77.4 years). Of 27 eyes that had late AMD, 17 (63%) had wet AMD. Mean patient preoperative CDVA was logMAR 0.32±0.29. Postoperative monocular CDVA and DCNVA were logMAR 0.20±0.25 and N9±5 (range N5-N36), respectively. Eyes achieving postoperative CDVA of Snellen 6/5-6/12 (n=42, 82%), 6/15-6/24 (n=7, 14%), and greater than 6/24 (n=2, 4%) achieved a mean DCNVA of N8 (range N5-N10), N13 (range N10-N18), and N27 (range N18-N36), respectively. Eyes achieving CDVA of Snellen 6/5-6/12 showed contrast sensitivity within the normal range. On postoperative VF-14 questionnaire, patients with CDVA of Snellen 6/5-6/12 reported minimal visual impairment, while patients with CDVA greater than 6/15 reported mild impairment. A majority of patients (96%, n=27) were satisfied with the improvement in quality of life postoperatively. No intraoperative complications were reported. Conclusion The EDOF AcrySof IQ Vivity IOL provides improved near vision proportional to distance vision in patients with early AMD.
Collapse
Affiliation(s)
| | - Anna Siu
- Personal-Eyes, Sydney, NSW, Australia
| | | | | |
Collapse
|
10
|
De la Paz M, Tsai LM. Outcomes and predictive factors in multifocal and extended depth of focus intraocular lens implantation. Curr Opin Ophthalmol 2024; 35:28-33. [PMID: 37910172 DOI: 10.1097/icu.0000000000001013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
PURPOSE OF REVIEW Options for addressing presbyopia with intraocular lens (IOL) implantation have become more varied and sophisticated. We reviewed recent literature on multifocal and extended depth of focus (EDOF) IOLs in order to provide insight on their respective advantages, with emphasis on the visual outcomes of each design. RECENT FINDINGS Increased patient age, spectral domain optical coherence tomography (SD-OCT) abnormalities, abnormal optical axis measurements, and better preoperative visual acuity have been implicated as predictors of worse postoperative vision or visual quality in multifocal IOLs. Despite differences in objective outcomes, patient-reported outcomes such as satisfaction are consistently similar between multifocal and EDOF IOLs. EDOFs may have slightly lower rates of spectacle independence than trifocals, but there is more support for their use in the setting of with other ocular conditions. SUMMARY Multifocal and EDOF IOLs are both viable options for patients who wish to preserve near vision. Given their similar objective performance in many aspects, enabling patients to make informed decisions based on their expectations and visual requirements is critical to postoperative satisfaction. Evidence for advanced technology IOL implantation in pediatric patients remains inconclusive.
Collapse
Affiliation(s)
- Matthew De la Paz
- Department of Ophthalmology, Washington University School of Medicine, St. Louis, Missouri, USA
| | | |
Collapse
|
11
|
Kohnen T, Nouri SA, Carson D. Vehicle Headlight Halo Simulation of Presbyopia-Correcting Intraocular Lenses. Transl Vis Sci Technol 2023; 12:19. [PMID: 38127324 PMCID: PMC10746926 DOI: 10.1167/tvst.12.12.19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 10/16/2023] [Indexed: 12/23/2023] Open
Abstract
Purpose This optical bench study was designed to evaluate and compare the halos generated by presbyopia-correcting intraocular lenses (PCIOLs) and monofocal intraocular lenses (IOLs), with or without lens decentration, using an optical bench to simulate the headlight of a distant vehicle in mesopic conditions. Methods Halos generated by six nondiffractive and 10 diffractive IOLs with different dioptric add powers were evaluated using a high dynamic range bench system. Halo intensities were compared by assessing the area under the measured intensity profile curve to compute the relative halo magnitude (RHM). Results Nondiffractive PCIOLs produced smaller and less intense bench halo images than diffractive ones. RHM measurements ranged from 964 to 1896. Monofocal IOLs produced lower RHM values, whereas diffractive PCIOLs generated higher ones. When decentered by 0.5 mm with respect to the system aperture, more obviously asymmetric halo image profiles were observed in diffractive compared with nondiffractive PCIOLs. Conclusions Simulated bench halos of nondiffractive PCIOLs are smaller and less intense than those of diffractive PCIOLs. Additional clinical studies assessing standardized patient-reported outcomes measures are required to correlate these bench results with patient satisfaction. Translational Relevance This study contrasts the design-related simulated bench halos of nondiffractive and diffractive PCIOLs, aiming to elucidate their impact on halo perception.
Collapse
Affiliation(s)
- Thomas Kohnen
- Department of Ophthalmology, Goethe University, Frankfurt, Germany
| | | | | |
Collapse
|
12
|
Bafna S, Gu X, Fevrier H, Merchea M. IRIS ® Registry (Intelligent Research In Sight) Analysis of the Incidence of Monovision in Cataract Patients with Bilateral Monofocal Intraocular Lens Implantation. Clin Ophthalmol 2023; 17:3123-3129. [PMID: 37877114 PMCID: PMC10591682 DOI: 10.2147/opth.s424195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Accepted: 10/06/2023] [Indexed: 10/26/2023] Open
Abstract
Purpose To determine the incidence of pseudophakic monovision among patients bilaterally implanted with monofocal intraocular lenses (IOLs) and to characterize the distribution of myopic offsets achieved. Patients and Methods This retrospective database study included data on patients receiving care from ophthalmologists who contributed to the Academy IRIS® (Intelligent Research In Sight) Registry. Anonymized data were collected, including patient age, ethnicity, procedure data (CPT code, date, laterality), and postoperative manifest refractive spherical equivalent (MRSE) in both eyes implanted with monofocal or monofocal toric IOLs. No data regarding IOL manufacturer, model, or power were collected. One primary outcome measure was the percentage of patients achieving monovision (defined as emmetropia within ±0.25 diopters [D] in one eye and a myopic offset of ≥0.50 D in the fellow eye) among all patients receiving bilateral monofocal IOLs at the time of cataract surgery between January 1, 2016, and September 1, 2019, with at least 90 days of follow-up. Other primary outcomes included the distribution and frequency of myopic offsets (anisometropia) between eyes. Results Of the 16,765 people receiving bilateral monofocal IOLs within the study period, 4796 (28.6%) achieved emmetropia in at least one eye, as defined by an MRSE within ± 0.25 D. The incidence of monovision among these patients was 34.2% (1638/4796). One-quarter (24.7%; 405/1638) of patients who achieved monovision had a myopic offset between 0.50 and 0.74 D, with more than one-third (35.2%; 576/1638) falling within 0.75-1.24 D and 18.0% within 1.25-1.74 D. A myopic offset ≥1.75 D was observed in 22.1% (362/1638) of patients who achieved monovision. Conclusion Pseudophakic monovision for presbyopia correction was achieved in ~34% of patients in the IRIS Registry bilaterally implanted with monofocal IOLs, with myopic offsets typically ranging from 0.5 to 1.24 D.
Collapse
|
13
|
Baur ID, Yan W, Auffarth GU, Khoramnia R, Łabuz G. Optical Quality and Higher Order Aberrations of Refractive Extended Depth of Focus Intraocular Lenses. J Refract Surg 2023; 39:668-674. [PMID: 37824300 DOI: 10.3928/1081597x-20230831-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2023]
Abstract
PURPOSE To compare the optical quality and higher order aberrations of four different refractive extended depth of focus intraocular lens (EDOF IOL) models (Lentis Comfort [Teleon Surgical BV], MiniWell (SIFI), LuxSmart [Bausch & Lomb], and AcrySof IQ Vivity [Alcon Laboratories, Inc]) and a monofocal IOL (Tecnis ZCB00; Johnson & Johnson Surgical Vision, Inc). METHODS An optical metrology instrument (OptiSpheric IOL PRO2; Trioptics GmbH) was used to study image quality metrics of the different IOLs. The modulation transfer function (MTF) was measured at pupil sizes 1 to 5 mm in 1-mm steps. Area under the MTF and simulated visual acuity were calculated for different pupil diameters. Wavefront aberrations were measured with the SHS Ophthalmic device (Optocraft GmbH), which features a Hartmann-Shack sensor. RESULTS All EDOF lenses yielded a simulated far visual acuity of 0.00 logMAR (20/20 Snellen) or better. At the 0.20 logMAR visual acuity level, the EDOF IOLs showed an increased depth of focus of at least 0.75 diopters compared to the monofocal IOL. Pupil dependency was more pronounced with the MiniWell, LuxSmart, and Vivity, whereas the Lentis showed a more consistent behavior at different apertures. The wavefront measurement revealed increased central aberrations for the MiniWell, LuxSmart, and Vivity IOL compared to the monofocal control. CONCLUSIONS All EDOF IOLs demonstrated increased depth of focus while maintaining good simulated visual acuity at the far focus. Pupil dependency differed between the IOL models. The wavefront analysis revealed the complex design of the different EDOF IOLs with several zones with varying aberrations. [J Refract Surg. 2023;39(10):668-674.].
Collapse
|
14
|
Fernández J, Srinivasan S, Burguera N, Martínez J, Rodríguez-Vallejo M. One-year follow-up of a multifocal intraocular lens with optimized elevated phase shift. J Cataract Refract Surg 2023; 49:1018-1024. [PMID: 37464551 DOI: 10.1097/j.jcrs.0000000000001266] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 07/13/2023] [Indexed: 07/20/2023]
Abstract
PURPOSE To evaluate the standard outcomes of a multifocal intraocular lens (mIOL) with optimized elevated phase shift (EPS). SETTING Qvision, Ophthalmology Department, VITHAS Almería, Spain. DESIGN Retrospective observational. METHODS 41 patients, consecutively operated on cataracts or refractive lens exchange with the implantation of the Liberty 640PM (EPS 2.0) and followed during 12 months, were included in the analysis. Retrieved variables were visual acuities at far, intermediate, and near distances; defocus curves (VADC); and prediction error of 4 formulas optimized for IOLMaster 500 and Pentacam AXL Wave. Patient-reported outcomes were also obtained for assessing spectacle independence, satisfaction, bothersome to dysphotopsia, difficulties in daily life tasks, and decision to be operated with the same mIOL. RESULTS The median monocular efficacy with best distance correction was 0, 0.1, and 0.1 logMAR at far, intermediate, and near distances, respectively, with patients achieving binocularly a median of 0 logMAR at the 3 distances. VADC showed a depth of field of 3 diopters (D) above 0.2 logMAR with a median increase of 0.07 logMAR from -1.5 to -2.5 D. Complete spectacle independence was achieved at far distance, whereas 97.6% and 85.4% was achieved at intermediate and near distances, respectively. 7.3% of patients were bothered by dysphotopsia, and 92.6% of patients were likely to be operated again. CONCLUSIONS EPS 2.0 restored patients' vision in the full range of the depth of field with a nearly monotone decrease of visual performance from far to near, achieving high rates of spectacle independence at all distances and with low positive dysphotopsia rates ( ClinicalTrials.gov Identifier: NCT05735990).
Collapse
Affiliation(s)
- Joaquín Fernández
- From the Qvision, Department of Ophthalmology, VITHAS Almería Hospital, Almería, Spain (Fernández, Burguera, Martínez, Rodríguez-Vallejo); Department of Ophthalmology, University Hospital Ayr, Ayr, Scotland (Srinivasan)
| | | | | | | | | |
Collapse
|
15
|
Nam JW, Lee JH, Zhang H, Sung MS, Park SW. Comparison of the Visual Outcomes of Enhanced and Standard Monofocal Intraocular Lens Implantations in Eyes with Early Glaucoma. J Clin Med 2023; 12:5830. [PMID: 37762769 PMCID: PMC10531790 DOI: 10.3390/jcm12185830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 09/05/2023] [Accepted: 09/06/2023] [Indexed: 09/29/2023] Open
Abstract
This study aimed to compare the efficacies and safety of enhanced and standard monofocal intraocular lenses (IOLs) in eyes with early glaucoma. Patients with concurrent cataracts and open-angle glaucoma (OAG) were enrolled. They underwent cataract surgery with IOL implantation. The comprehensive preoperative ophthalmic examination included the manifest refraction; monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA); visual field (VF); and contrast sensitivity (CS); defocus curves and questionnaires were assessed three months postoperatively. Totals of 34 and 38 patients had enhanced and standard monofocal IOLs, respectively. The enhanced monofocal IOL provided better UIVA than the standard monofocal IOL (p = 0.003) but similar UDVA, CDVA, and UNVA. The enhanced monofocal IOL had more consistent defocus curves than the standard monofocal IOL, especially at -1 (p = 0.042) and -1.5 (p = 0.026) diopters. The enhanced monofocal IOL provided better satisfaction (p = 0.019) and lower spectacle dependence (p = 0.004) than the standard monofocal IOL for intermediate vision, with similar VF and CS outcomes. In conclusion, enhanced monofocal IOLs are recommended for patients with OAG because they provide better intermediate vision, higher satisfaction, and lower dependence on spectacles than standard monofocal IOLs, without worsening other visual outcomes.
Collapse
Affiliation(s)
| | | | | | | | - Sang Woo Park
- Department of Ophthalmology, Chonnam National University Medical School and Hospital, Gwangju 61469, Republic of Korea
| |
Collapse
|
16
|
Marín JM, Hervella L, Villegas E, Robles C, Alcón E, Yago I, Artal P. Visual Performance at All Distances and Patient Satisfaction With a New Aspheric Inverted Meniscus Intraocular Lens. J Refract Surg 2023; 39:582-588. [PMID: 37675912 DOI: 10.3928/1081597x-20230802-01] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
PURPOSE To evaluate visual performance, spectacle independence, and quality of vision of new intraocular lenses (IOLs) for presbyopia correction with an aspheric inverted meniscus optical design (ArtIOLs; Voptica SL) in patients undergoing bilateral cataract surgery. METHODS In this prospective study, 60 eyes from 30 patients implanted bilaterally with Art40 and Art70 IOLs were included. These new IOLs were designed with an inverted meniscus shape to improve the peripheral performance and with aspheric surfaces to induce different amounts of negative spherical aberration in each IOL model. Distance-corrected and uncorrected through-focus visual acuities and contrast sensitivity were measured 1 to 3 months after surgery. Twenty-eight patients answered Patient Reported Spectacle Independence (PRSIQ) and Quality of Vision (QoV) questionnaires. RESULTS Mean monocular (Art40 and Art70) and binocular (Art40/70) corrected distance visual acuities (CDVA) were zero logMAR (20/20). Binocular uncorrected distance visual acuity (UDVA) at far, intermediate (66 cm), and near (40 cm) distances was 0.00 ± 0.01, 0.01 ± 0.03, and 0.09 ± 0.09 logMAR, respectively. Spectacle independence was achieved by 24 (85.7%) patients for far and intermediate vision and 20 patients (71.4%) for near vision. The number of patients never reporting experiencing glare, halos, and starbursts was 28, 27, and 26 (100%, 96.4%, and 92.9%), respectively. CONCLUSIONS The binocular combination of two ArtIOLs models (Art40 and Art70) significantly extended the depth of focus up to at least 40 cm. This combination resulted in a full range of vision with a high level of spectacle independence and without the compromise of halos or dysphotopsias. [J Refract Surg. 2023;39(9):582-588.].
Collapse
|
17
|
Kohnen T, Berdahl JP, Hong X, Bala C. The Novel Optical Design and Clinical Classification of a Wavefront-Shaping Presbyopia-Correcting Intraocular Lens. Clin Ophthalmol 2023; 17:2449-2457. [PMID: 37614847 PMCID: PMC10443698 DOI: 10.2147/opth.s400083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Accepted: 04/21/2023] [Indexed: 08/25/2023] Open
Abstract
Purpose To evaluate the clinical rationale of wavefront-shaping technology, describe how intraocular lenses (IOLs) using wavefront-shaping technology are differentiated from refractive or diffractive optical presbyopia-correcting designs, and describe the mode of action of this technology. Methods Extended depth of focus (EDoF) IOLs are the latest class of presbyopia-correcting IOLs addressing the growing demand of patients for reduced spectacle dependence. These use various optical technologies, including diffractive designs (eg, TECNIS Symfony ZXR00 and AT LARA 29 MP) and non-diffractive designs such as small aperture (eg, IC-8 IOL and XtraFocus Pinhole Implant), spherical aberration (eg, MINI WELL Ready and LuxSmart), and wavefront shaping (eg, AcrySof IQ Vivity DFT015 and Clareon Vivity CNWET0). Despite some improvement in visual acuity at intermediate and near distances, these technologies can still be associated with increased rate of visual disturbances or poorer distance vision compared with monofocal IOLs. One way to overcome such limitations is using a wavefront-shaping optical principle. Results Clinical data show that wavefront-shaping technology results in a continuous EDoF compared with a monofocal IOL while exhibiting a minimal halo, similar to an aspheric monofocal IOL. Clinically, this translates to a lens that has proven to exceed the American National Standards Institute/American Academy of Ophthalmology criteria for an EDoF IOL. Conclusion The novel wavefront-shaping optic technology allows patients to achieve a continuous range of vision from distance to functional near with low levels of visual disturbances comparable with aspheric monofocal IOLs.
Collapse
Affiliation(s)
- Thomas Kohnen
- Department of Ophthalmology, Goethe University Frankfurt, Frankfurt am Main, Germany
| | | | - Xin Hong
- Alcon Vision LLC, Fort Worth, TX, USA
| | | |
Collapse
|
18
|
Barber KM, O’Connor S, Mackinder P, Chih A, Jones B. Rotational stability and refractive outcomes of the DFT/DATx15 toric, extended depth of focus intraocular lens. Int Ophthalmol 2023; 43:2737-2747. [PMID: 36894823 PMCID: PMC10371906 DOI: 10.1007/s10792-023-02673-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 02/20/2023] [Indexed: 03/11/2023]
Abstract
PURPOSE To quantitatively assess postoperative rotational stability and visual acuity with the DFT/DATx15 extended depth of focus (EDOF) toric intraocular lens (IOL). METHODS In this prospective case series, thirty-five patients with a calculated IOL power between + 15.0 D and + 25.0 D, corneal astigmatism between 0.75 D and 2.25 D, and no significant ocular pathology underwent cataract surgery. Primary outcome was rotational stability of the IOL at 1 month post-operatively. Secondary outcomes included residual refractive astigmatism, absolute residual astigmatism prediction error, and monocular distance and intermediate visual acuities. RESULTS Mean absolute postoperative IOL rotation was 1.1 ± 0.2 degrees, with no rotation of more than 3 degrees at the final visit. Monocular mean best spectacle-corrected distance visual acuity (BSCDVA) improved from logMAR 0.27 ± 0.030 to 0.078 ± 0.017 (P < .001). Monocular uncorrected distance visual acuity (UCDVA) improved from 0.93 ± 0.096 to 0.18 ± 0.022 (P < .001). Best spectacle-corrected intermediate visual acuity (DSCIVA) was 0.17 ± 0.025, and uncorrected intermediate visual acuity (UCIVA) was 0.27 ± 0.040. Residual regular astigmatic refractive error was 0.21 ± 0.047 D. CONCLUSIONS The toric DFT/DATx15 EDOF lens showed excellent rotational stability and effective and predictable correction of astigmatism. Its refractive outcomes and safety profile were similar to those identified in prior studies of the non-toric DFT/DAT015 EDOF IOL. A small difference in monocular BSCDVA, of uncertain clinical significance, was found when comparing these outcomes with prior DFT/DAT015 data. The trial was retrospectively registered on November 5, 2021 (TRN NCT05119127).
Collapse
Affiliation(s)
- Kevin M. Barber
- Central Florida Eye Specialists, 968 International Parkway, Lake Mary, FL 32746 USA
| | - Sara O’Connor
- Central Florida Eye Specialists, 968 International Parkway, Lake Mary, FL 32746 USA
| | - Philip Mackinder
- Central Florida Eye Specialists, 968 International Parkway, Lake Mary, FL 32746 USA
| | - Andreea Chih
- Central Florida Eye Specialists, 968 International Parkway, Lake Mary, FL 32746 USA
| | - Brian Jones
- Central Florida Eye Specialists, 968 International Parkway, Lake Mary, FL 32746 USA
| |
Collapse
|
19
|
Solomon KD, Sandoval HP, Potvin R. Visual outcomes, satisfaction, and spectacle independence with a nondiffractive extended vision intraocular lens targeted for slight monovision. J Cataract Refract Surg 2023; 49:686-690. [PMID: 37000976 DOI: 10.1097/j.jcrs.0000000000001191] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 03/27/2023] [Indexed: 04/03/2023]
Abstract
PURPOSE To evaluate vision, satisfaction, and spectacle independence of the AcrySof IQ Vivity intraocular lens when the nondominant eye is targeted for slight myopia. SETTING 1 clinical practice in the United States. DESIGN Prospective unmasked nonrandomized clinical trial. METHODS Patients presenting for cataract surgery interested in reducing their dependence on spectacles were enrolled, with the dominant eye targeted for emmetropia and the nondominant eye targeted for slight monovision (-0.50 diopters [D]). Visual disturbances, satisfaction, and spectacle independence were evaluated. Visual acuity (VA) was tested at distance (4 m), intermediate (66 cm), and near (40 cm) at 3 months postoperatively when uncorrected, with both eyes corrected to emmetropia and with 1 eye adjusted for monovision. 2 binocular defocus curves were also collected under the latter 2 conditions. RESULTS Data from 31 patients were analyzed. The mean refractive spherical equivalent was 0.45 D more myopic in the nondominant eye, resulting in worse uncorrected VA at distance but better uncorrected VA at near. The binocular defocus curve with monovision showed significantly better VA from -2.0 to -3.0 D, and patients reported less need for spectacles (and better vision) at near than reported with binocular emmetropia. Glare, blurred vision, and starbursts were the most reported visual disturbances. Although not correlated with the difference in refraction, glare and blurred vision were significantly correlated with overall satisfaction. CONCLUSIONS Implanting this IOL with a target of slight myopia in the nondominant eye appears to be a viable way to improve near vision, although with an increased potential for visual disturbances.
Collapse
Affiliation(s)
- Kerry D Solomon
- From the Carolina Eyecare Physicians, LLC, Mt. Pleasant, South Carolina (Solomon, Sandoval); Science in Vision, Bend, Oregon (Potvin)
| | | | | |
Collapse
|
20
|
Asena L, Kırcı Dogan İ, Oto S, Dursun Altınors D. Comparison of visual performance and quality of life with a new nondiffractive EDOF intraocular lens and a trifocal intraocular lens. J Cataract Refract Surg 2023; 49:504-511. [PMID: 36700928 DOI: 10.1097/j.jcrs.0000000000001142] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 01/04/2023] [Indexed: 01/27/2023]
Abstract
PURPOSE To compare visual performance and quality of life (QoL) following bilateral implantation of a new nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) and a trifocal IOL. SETTING Department of Ophthalmology, Baskent University Faculty of Medicine, Ankara, Turkey. DESIGN Prospective comparative interventional case series. METHODS 104 eyes of 52 patients with cataract, bilaterally implanted with a nondiffractive EDOF IOL or a trifocal IOL, were included. Outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity and distance corrected near visual acuity, defocus curves, QoL (Visual Function Index 14), quality of vision (Quality of Vision [QoV] index), contrast sensitivity (Pelli-Robson chart), and binocular reading speed. RESULTS Twenty-six patients were included in each group. The UDVA and CDVA were better in the EDOF group (0.05 ± 0.04 and 0.01 ± 0.04) than the trifocal group (0.13 ± 0.06 and 0.11 ± 0.07) ( P = .02 and .01). Defocus curves showed that visual acuity was better with the EDOF IOL for vergences at 0.00, -0.50, and -1.00 and better with the trifocal IOL for vergences at -2.50, -3.00, -3.50, and -4.00. Contrast sensitivity scores were similar with both IOLs ( P = .12). The overall mean QoL scores were lower in the EDOF group, indicating a better QoL ( P = .04). The QoV was better in the EDOF group with significantly less glare, halos, and blurry vision ( P < .01). CONCLUSIONS The EDOF IOL performed better at distance, and the trifocal IOL performed better at near. Overall QoL and quality of vision were better with the EDOF IOL.
Collapse
Affiliation(s)
- Leyla Asena
- From the Department of Ophthalmology, Baskent University Faculty of Medicine, Ankara, Turkey
| | | | | | | |
Collapse
|
21
|
Scheepers MA, Hall B. Randomized and double-blind comparison of clinical visual outcomes of 2 EDOF intraocular lenses. J Cataract Refract Surg 2023; 49:354-359. [PMID: 36975011 DOI: 10.1097/j.jcrs.0000000000001113] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 11/29/2022] [Indexed: 03/29/2023]
Abstract
PURPOSE To assess and compare the visual disturbance profiles of 2 extended depth-of-focus (EDOF) intraocular lenses (IOLs). SETTING Private practice (West Kootenays, British Columbia, Canada). DESIGN Prospective, randomized, single-surgeon study. METHODS This was a double-blind prospective study of 138 eyes (69 patients) that underwent bilateral implantation of 1 of 2 EDOF IOLs. Participants were randomized to either the Symfony group or the Vivity group. Outcome measures included Questionnaire for Visual Disturbances; binocular corrected distance visual acuities at distance (6 m), intermediate (66 cm), and near (40 cm); and refractive outcomes. RESULTS At 3 months postoperatively, 21 patients (60%) reported not experiencing glare in the Symfony group compared with 30 (88%) in the Vivity group, a difference of 28% (P = .008). Reports of experiencing starbursts were also significantly different between the Symfony and Vivity groups (23 participants [66%] Symfony and 30 participants [88%] Vivity; P = .027). In addition, 12 participants (34%) reported "moderate" or "severe" starbursts in the Symfony group compared with 3 (9%) in the Vivity group, a difference of 25% (P = .019). Visual acuities and refractive outcomes were similar between groups. CONCLUSIONS Both EDOF lenses provide good visual outcomes at distance and intermediate with acceptable near vision. The Symfony group had increased reports of some visual disturbances, notably the frequency, severity, and bothersomeness of starbursts and glare.
Collapse
Affiliation(s)
- Marius A Scheepers
- From the University of British Columbia, Kelowna, British Columbia, Canada (Scheepers); Sengi, Penniac, New Brunswick, Canada (Hall)
| | | |
Collapse
|
22
|
Madrid-Costa D, Fernández-Vega-Cueto L, Azor-Morón JA, Vega F, Millán MS, Alfonso JF. Beam-Shaping Extended Depth of Focus Intraocular Lens: Optical Assessment With Corneas of Increasing Spherical Aberration. J Refract Surg 2023; 39:95-102. [PMID: 36779468 DOI: 10.3928/1081597x-20221215-02] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
PURPOSE To assess the optical quality and halo formation of a beam-shaping extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity; Alcon Laboratories, Inc) with corneas of long-range spherical aberration (SA) such as those resulting from myopic laser ablations. METHODS The optical quality of the EDOF IOL and a reference monofocal IOL was evaluated with three corneas (A, B, and C, with SA =+0.135, +0.290, +0.540 µm, respectively, for a 5.15-mm pupil at the IOL plane). The through-focus modulation transfer function area (MTFa) curves were obtained between -5.00 and +2.00 diopters (D) defocus range. The halo was also assessed with the three corneas. RESULTS Through-focus MTFa curves for a 4.5-mm IOL pupil showed a slight decrease in the maximum MTFa value provided by the EDOF IOL compared to the monofocal IOL in the three corneal situations (A: 45.9 vs 38.6 units; B: 41.1 vs 33.1 units, and C: 26.9 vs 23.8 units). For the 3.0-mm pupil, the EDOF IOL also had lower maximum MTFa than the monofocal IOL; however, the depth-of-focus increased to -2.20 D. With corneas A and B, the halo induced was of low energy with both IOLs. With cornea C, the EDOF IOL created a much larger and intense halo. CONCLUSIONS The EDOF IOL provided a good distance optical performance and an extended range of focus of approximately 2.00 D, with a halo of low intensity when evaluated with a corneal SA similar to the one induced by a low to moderate myopic ablation. With a high myopic ablation, the halo induced would be of considerable size and energy. [J Refact Surg. 2023;39(2):95-102.].
Collapse
|
23
|
Tomagova N, Elahi S, Vandekerckhove K. Clinical Outcomes of a New Non-Diffractive Extended Depth-of-Focus Intraocular Lens Targeted for Mini-Monovision. Clin Ophthalmol 2023; 17:981-990. [PMID: 37007049 PMCID: PMC10053890 DOI: 10.2147/opth.s405267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 03/13/2023] [Indexed: 04/04/2023] Open
Abstract
Purpose To assess visual acuity, binocular defocus curve, spectacle independence, and photic phenomena after bilateral same-day cataract surgery with implantation of an extended depth-of-focus intraocular lens (IOL) with mini-monovision. Methods Single-center retrospective study including 124 eyes from 62 patients who underwent bilateral implantation of an isofocal EDOF lens [Isopure® (BVI)] with mini-monovision (-0.50 D). Refraction, visual acuity at different distances, binocular defocus curves, spectacle independence, and subjective ratings of picture-referenced photic phenomena were assessed one to two months postoperatively. Results The mean postoperative refractive spherical equivalent was -0.15±0.41D in the dominant eyes and -0.46±0.35D in the mini-monovision eyes (p<0.01). Overall, 98.4% and 87.7% of the eyes were within ±1.00D and ±0.50D of the target refraction, respectively. Postoperative monocular corrected distance visual acuity was -0.04±0.07 logMAR. Binocular uncorrected visual acuity was -0.02±0.07, 0.13±0.11and 0.40±0.20 logMAR for far, intermediate and near, respectively. At the visual acuity threshold of 0.20 logMAR (or better) the defocus curve ranged from -1.6D to +0.9D. Reported spectacle-independence was 96% for far distance, 95% for intermediate, and 34% for near. Five percent of patients reported halos, 16% starburst, and 16% glare. Only 7% of all patients considered them bothersome. Conclusion In patients undergoing same-day bilateral cataract surgery, an isofocal EDOF lens provided an extended range of functional vision, up to 63 cm, resulting in useful uncorrected near vision, good uncorrected intermediate vision, and excellent uncorrected distance vision. Subjective patient satisfaction in terms of spectacle independence and photic phenomena was high.
Collapse
Affiliation(s)
- Nikola Tomagova
- Clinical Study Department, Vista Alpina Eye Clinic, Visp, Switzerland
| | - Sina Elahi
- Clinical Study Department, Vista Alpina Eye Clinic, Visp, Switzerland
| | - Kristof Vandekerckhove
- Clinical Study Department, Vista Alpina Eye Clinic, Visp, Switzerland
- Correspondence: Kristof Vandekerckhove, Clinical Study Department, Vista Alpina Eye Clinic, Bahnhofplatz 1a, Visp, 3930, Switzerland, Tel +41279467000, Email
| |
Collapse
|
24
|
Sabur H, Unsal U. Visual outcomes of non-diffractive extended-depth-of-focus and enhanced monofocal intraocular lenses: A case-control study. Eur J Ophthalmol 2023; 33:262-268. [PMID: 36062601 DOI: 10.1177/11206721221125004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
OBJECTIVE To compare the visual outcomes of a non-diffractive extended-depth-of-focus (EDoF) intraocular lens (IOL) with an enhanced monofocal IOL. METHODS We evaluated 76 eyes from 38 patients who had undergone bilateral cataract surgery with implantation of either an EDoF IOL (AcrySof IQ Vivity, n = 40 eyes) or an enhanced monofocal IOL (Tecnis Eyhance, n = 36 eyes). Objective refraction, monocular and binocular uncorrected and corrected distance visual acuity (UDVA, CDVA), uncorrected and distance-corrected intermediate visual acuity (UIVA, DCIVA), uncorrected and distance-corrected near visual acuity (UNVA, DCNVA), binocular defocus curves, contrast sensitivity, halo and glare perception, and spectacle independence were compared. RESULTS Monocular and binocular UDVA, CDVA, UIVA, and DCIVA were comparable in both groups, whereas UNVA and DCNVA were significantly better with the Vivity group than with the Eyhance group. The two groups had no statistically significant difference regarding photopic and scotopic contrast sensitivities or halo and glare perception. Compared to the Eyhance IOL, the Vivity IOL had a larger landing zone in the defocus curve and provided higher spectacle independence for near vision. CONCLUSION Both the AcrySof IQ Vivity and Tecnis Eyhance IOLs had excellent distant and intermediate visual acuity, while the former had more satisfactory near vision outcomes with greater spectacle independence rate. No differences were obtained between two IOLs in terms of patient satisfaction and visual disturbances such as halo and glare.
Collapse
Affiliation(s)
- Huri Sabur
- Department of Ophthalmology, University of Health Sciences Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey
| | - Ugur Unsal
- Department of Ophthalmology, Batigoz Eye Health Center, Izmir, Turkey
| |
Collapse
|
25
|
Kandavel R, Colvard M, Dredge J, Bayle M, Alam T, Snyder J, Hall B. Comparative Study Between Non-Diffractive Extended Depth of Focus and Monofocal Intraocular Lenses. Clin Ophthalmol 2023; 17:1161-1168. [PMID: 37082300 PMCID: PMC10112466 DOI: 10.2147/opth.s402069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 03/30/2023] [Indexed: 04/22/2023] Open
Abstract
Purpose To evaluate the visual acuity and quality of vision in bilaterally implanted ZCBOO/ZCTx monofocal (Johnson & Johnson Vision) intraocular lens (IOL) and bilaterally implanted DATx15 extended depth of focus (EDOF) IOL (Alcon Vision, LLC). Methods A single site, non-interventional study comparing ZCBOO/ZCTx monofocal IOL patients implanted with DATx15 IOL toric or non-toric versions in both eyes. A total of 30 patients (60 eyes) completed the study in the monofocal group, 32 (64 eyes) in the EDOF group, and all were targeted for emmetropia. Binocular uncorrected distance, intermediate (66cm), and near (40cm) visual acuities and distance corrected distance, intermediate (66cm) and near (40cm) visual acuities were assessed. Binocular distance corrected defocus curve testing was from -3.5 D to +3 D. Patient reported visual disturbances (QUVID) and IOL satisfaction (IOLSAT) questionnaires were administered. Results The DATx15 group mean uncorrected visual acuity was 0.15 ± 0.10 logMAR at 66cm and 0.36 ± 0.14 logMAR at 40cm, compared to 0.24 ± 0.15 logMAR and 0.59 ± 0.17 logMAR respectively for the ZCBOO/ZCTx group. The DATx15 group (23 respondents, 74%) also reported significantly more spectacle independence at near with the IOLSAT (p < 0.01), compared to the ZCBOO/ZCTx group (13 respondents, 43%). Glare, halos, starbursts, and blur reported on the QUVID questionnaire were similar in the two groups. Conclusion The DATx15 group had improved near and intermediate vision and increased spectacle independence compared to the ZCBOO/ZCTx group.
Collapse
Affiliation(s)
- Rom Kandavel
- Colvard-Kandavel Eye Center, Encino, CA, 91316, USA
- Correspondence: Rom Kandavel, Colvard-Kandavel Eye Center, 5363 Balboa Blvd Suite 540, Encino, CA, 91316, USA, Tel +1-818-906-2929, Email
| | | | | | | | - Tamanna Alam
- Colvard-Kandavel Eye Center, Encino, CA, 91316, USA
| | - James Snyder
- Colvard-Kandavel Eye Center, Encino, CA, 91316, USA
| | | |
Collapse
|
26
|
Ferguson TJ, Wilson CW, Shafer BM, Berdahl JP, Terveen DC. Clinical Outcomes of a Non-Diffractive Extended Depth-of-Focus IOL in Eyes with Mild Glaucoma. Clin Ophthalmol 2023; 17:861-868. [PMID: 36945324 PMCID: PMC10024873 DOI: 10.2147/opth.s404369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 03/08/2023] [Indexed: 03/17/2023] Open
Abstract
Purpose To evaluate the clinical outcomes of a non-diffractive, wavefront-shaping extended depth-of-focus (EDOF) intraocular lens (IOL) in eyes with mild open-angle glaucoma (OAG). Setting Private practice; Sioux Falls, South Dakota. Design Prospective, open-label, interventional study. Methods In total, 52 eyes of 26 patients with mild OAG were enrolled and completed the study. All patients were bilaterally implanted with a non-diffractive, wavefront-shaping EDOF IOL. Seventy-seven percent of the patients were implanted with a trabecular microbypass stent at the time of surgery. Primary outcome measures included binocular corrected and uncorrected distance visual acuity (CDVA and UDVA), uncorrected intermediate and near visual acuity (UIVA and UNVA) and contrast sensitivity as measured by a Pelli-Robson chart. A subjective questionnaire was also administered to patients. Results At 4 months postoperative, the mean binocular UDVA and CDVA was 0.03 ± 0.12 and -0.06 ± 0.07, respectively. The mean UIVA and UNVA were 0.18 ± 0.12 and 0.31 ± 0.18, respectively. Eighty-five percent of the subjects achieved ≥20/25 UDVA and 77% of the subjects achieved ≥20/32 UIVA at 4 months postoperative. The mean binocular mesopic contrast sensitivity was 1.76 ± 0.16 at a spatial frequency of 1 cycle-per-degree (cpd). Eighty-five percent of the subjects reported they would choose the same lens and 1 subject reported they would choose a different IOL if it meant reduced spectacle independence. Conclusion The non-diffractive, wavefront-shaping EDOF IOL can be safely implanted in eyes with mild, pre-perimetric open-angle glaucoma with favorable uncorrected distance and intermediate visual acuity. The contrast sensitivity measurements were favorable and the subjective questionnaire revealed satisfactory spectacle independence and patient satisfaction.
Collapse
Affiliation(s)
- Tanner J Ferguson
- Vance Thompson Vision, Sioux Falls, SD, USA
- University of South Dakota Sanford School of Medicine, Sioux Falls, SD, USA
- Correspondence: Tanner J Ferguson, Vance Thompson Vision, 3101 W. 57th Street, Sioux Falls, SD, 57108, USA, Email
| | | | | | - John P Berdahl
- Vance Thompson Vision, Sioux Falls, SD, USA
- University of South Dakota Sanford School of Medicine, Sioux Falls, SD, USA
| | - Daniel C Terveen
- Vance Thompson Vision, Sioux Falls, SD, USA
- University of South Dakota Sanford School of Medicine, Sioux Falls, SD, USA
| |
Collapse
|
27
|
Intolerance of a non-diffractive extended-depth-of-focus IOL with mini-monovision. Am J Ophthalmol Case Rep 2022; 29:101770. [PMID: 36507465 PMCID: PMC9731877 DOI: 10.1016/j.ajoc.2022.101770] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 11/07/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
Purpose The use of a non-diffractive extended-depth-of-focus (EDOF) intraocular lens (IOL) with slight myopia of -0.5 D on the non-dominant eye increases the spectacle independence and has good subjective tolerance with optical phenomena comparable to those of a monofocal IOL. This case report describes the course of a myopic patient who underwent refractive lens exchange, didn't tolerate mini-monovision and received IOL exchange therefore. Observations A healthy, 62-year-old male with myopia of approximately -5 D underwent refractive lens exchange with a non-diffractive EDOF-IOL on both eyes with slight myopia on the non-dominant left eye (mini-monovision). The operation was performed without any complications, postoperative treatment was due to the clinic's standard procedure. Two weeks postoperative the patient presented with uncorrected distance visual acuity of 0.0 logMAR, a subjective refraction of -0.25/-0.25/142° and corrected distance visual acuity of 0.1 logMAR on the right eye. On the left eye, distance visual acuity was 0.4 logMAR with a subjective refraction of -0.5/-0.75/9° (intended mini-monovision) and corrected distance visual acuity of 0.0 logMAR. Binocular distance visual acuity was 0.0 logMAR. The patient complained about the occurrence of optical phenomena at dim light while driving a car and subjective reduced visual acuity. After an IOL exchange on the left eye with the implantation of the same type of non-diffractive EDOF-IOL aimed for emmetropia, the patient was symptom-free and reported no more subjective complaints. Conclusions Despite the satisfying subjective and objective visual outcome which is proven in multiple studies, the subjective perception of a mini-monovision with a non-diffractive EDOF-IOL can vary individually. A preoperative assessment of the patient's needs and tolerance of a mini-monovision is crucial for a satisfying postoperative outcome.
Collapse
|
28
|
Baur ID, Auffarth GU, Yan W, Łabuz G, Khoramnia R. Visualization of Ray Propagation through Extended Depth-of-Focus Intraocular Lenses. Diagnostics (Basel) 2022; 12:2667. [PMID: 36359510 PMCID: PMC9689910 DOI: 10.3390/diagnostics12112667] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 10/18/2022] [Accepted: 10/27/2022] [Indexed: 10/14/2023] Open
Abstract
Extended depth-of-focus (EDoF) presbyopia-correcting intraocular lens (IOL) models differ in their optical design and performance. In the laboratory, we compared the ray propagation and light intensity profiles of four IOLs: the non-diffractive AcrySof IQ Vivity (Alcon Inc., Fort Worth, TX, USA) and two diffractive models, Symfony ZXR00 (Johnson & Johnson Vision, Jacksonville, FL, USA) and AT Lara 829 MP (Carl Zeiss Meditec, Berlin, Germany). A fourth lens, the monofocal AcrySof IQ SN60WF (Alcon Inc.) acted as the control. We projected a 520 nm laser light through each submerged lens in a bath of fluorescein solution. A camera mounted on a microscope captured the light that emerged from the IOL. We recorded the IOLs' point spread function (PSF) to determine the presence of unwanted visual effects. The ray propagation visualization and light intensity profile of the monofocal control showed one distinct focus, while the AcrySof IQ Vivity demonstrated an extended focus area. We observed two distinct foci with each diffractive IOL. We found a lower level of light spread beyond the PSF center for the AcrySof IQ Vivity compared to the diffractive IOLs. In conclusion, we could confirm the extended range of focus for all the EDoF IOL models. However, the non-diffractive AcrySof IQ Vivity appears to have a smoother transition from a far to an intermediate range. We discuss whether, in clinical use, the higher level of spurious light we found in the diffractive designs may translate into increased dysphotopsia.
Collapse
|
29
|
McCabe C, Berdahl J, Reiser H, Newsom TH, Cibik L, Koch D, Lemp-Hull J, Jasti S. Clinical outcomes in a U.S. registration study of a new EDOF intraocular lens with a nondiffractive design. J Cataract Refract Surg 2022; 48:1297-1304. [PMID: 35616507 PMCID: PMC9622364 DOI: 10.1097/j.jcrs.0000000000000978] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 05/23/2022] [Indexed: 02/04/2023]
Abstract
PURPOSE To evaluate the effectiveness and safety of the DFT015 intraocular lens (IOL) (AcrySof IQ Vivity Extended Vision) compared with an aspheric monofocal control IOL (AcrySof IQ model SN60WF). SETTING 11 investigation sites in the U.S. DESIGN Prospective randomized controlled clinical study. METHODS Patients aged 22 years or older with bilateral cataracts were randomized to receive bilateral implantation of DFT015 or SN60WF. The 4 coprimary effectiveness outcomes (6 months postoperatively) were monocular photopic distance-corrected intermediate visual acuity (DCIVA), monocular photopic corrected distance visual acuity (CDVA), monocular depth of focus (DoF), and the percentage of patients achieving a DCIVA of 0.2 logMAR or better. The mean monocular photopic distance-corrected near visual acuity (DCNVA) was a secondary effectiveness outcome. Safety and patient-reported visual disturbances were evaluated through questionnaires. RESULTS 218 patients (435 eyes) completed the study. Compared with SN60WF, DFT015 demonstrated superior mean monocular photopic DCIVA ( P &lt; .001), noninferior mean monocular photopic CDVA, and superior mean monocular photopic DCNVA ( P &lt; .001) and provided an extended monocular DoF (increase of 0.54 diopters at 0.2 logMAR). With DFT015, 78 first eyes (72.9%) achieved a DCIVA of 0.2 logMAR or better at 6 months. Incidences of ocular serious adverse events and patient-reported most bothersome visual disturbances were low and consistent between groups. CONCLUSIONS DFT015 is safe and effective for the visual correction of aphakia, exceeding American National Standards Institute criteria for an extended depth-of-focus IOL by providing superior DCIVA and DCNVA, with comparable CDVA and visual disturbances to the SN60WF monofocal IOL.
Collapse
|
30
|
Evaluation of Visual and Patient-Reported Outcomes, Spectacle Dependence after Bilateral Implantation with a Non-Diffractive Extended Depth of Focus Intraocular Lens Compared to Other Intraocular Lenses. J Clin Med 2022; 11:jcm11175246. [PMID: 36079174 PMCID: PMC9456700 DOI: 10.3390/jcm11175246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/29/2022] [Accepted: 09/03/2022] [Indexed: 11/24/2022] Open
Abstract
Purpose: To evaluate postoperative outcomes, spectacle dependance and the occurrence of the photic phenomena in patients after cataract surgery following the implantation of a non-diffractive extended depth of focus (EDOF) intraocular lens was compared to monofocal and multifocal lenses. Methods: We enrolled patients with bilateral cataracts who wanted to reduce their dependence on glasses in the study. They were followed for 6 months. The study group in which the EDOF lens was implanted consisted of 70 eyes in 35 patients. The control groups consisted of: 52 eyes in 26 patients in whom a multifocal was implanted and 52 eyes in 26 patients with implanted monofocal lens. After a total of 2 weeks, 2 months and 6 months post-surgery the following were evaluated: uncorrected and corrected visual acuity at 4 m, 80 cm, 40 cm, manifest refraction expressed as mean refractive spherical equivalent (MRSE), contrast sensitivity, intraocular pressure. A questionnaire on independence from ocular correction, the occurrence of photic phenomena, and patient satisfaction was also completed. Results: Monocular and binocular visual acuity and MRSE 6 months after the procedure were compared between three groups. All of the main analyses, except for comparisons of uncorrected distance visual acuity (both monocular and binocular) level, were significant. Contrast sensitivity was lower among patients with multifocal lens than among patients with EDOF lens. Halo and glare after 6 months were seen more often among patients with multifocal lens than among patients with the other lens (65% of eyes with multifocal lens vs. 6% of eyes with EDOF lens and 0% of eyes with monofocal lens). Glasses were needed by 35% of patients with EDOF lens, and by 96% of patients with monofocal lens and in none of the patients with multifocal lens. Conclusions: Most patients qualify for the implantation of a non-diffractive EDOF lens. Post-operative visual acuity improves at any distance. The best monocular visual acuity for intermediate distances is provided by an EDOF lens, and for near distance by a multifocal lens. The EDOF lens definitely increases independence from spectacle correction compared to monofocal lenses; however, the greatest degree of independence from spectacles is provided by multifocal lenses. The incidence of photic phenomena is slightly higher than that of a monofocal lens, and much lower for a multifocal lens.
Collapse
|
31
|
Bala C, Athanasiov P, Holland J, Dhariwal M, Gupta A, Rathi H. A Cost-Effectiveness Analysis of AcrySof IQ Vivity Intraocular Lens (IOL) from Private Health Fund Perspective in Australia. Clin Ophthalmol 2022; 16:2403-2412. [PMID: 35942082 PMCID: PMC9356702 DOI: 10.2147/opth.s370420] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 06/29/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose AcrySof IQ Vivity is a unique non-diffractive extended depth of focus intraocular lens with wavefront-shaping X-WAVE technology. This study evaluated the cost-effectiveness of AcrySof IQ Vivity intraocular lens (DFT015) compared with standard aspheric monofocal intraocular lens (SN60WF), from a private health fund perspective in Australia. Methods A Markov model was developed using the following health states: well, need for spectacles (near/distance/bifocal/varifocal), very bothersome visual disturbances (glare/haloes/starbursts) – with/without spectacles, and death. Model inputs were sourced from a randomized clinical study (NCT03010254), published literature, prostheses list and clinical opinion. A lifetime horizon (up to 30 years) was considered, and cost and health outcomes were discounted at 5% per annum. Model outcomes included incremental cost–effectiveness ratio defined as incremental cost per quality adjusted life year gain. Sensitivity and scenario analyses were also conducted. Results Bilateral implantation of DFT015 intraocular lens provided quality adjusted life year gain of 0.16 at an incremental cost of AU$307 compared to bilateral SN60WF, leading to an incremental cost-effectiveness ratio of AU$1908/quality adjusted life year, well below the cost-effectiveness threshold (Range: AU$45,000-AU$75,000) typically used by Medical Services Advisory Committee in Australia. Results were most sensitive to intraocular lens costs, post-operative spectacle dependence, and disutility due to wearing glasses. Robustness of the results was further confirmed by probabilistic sensitivity analysis and scenario analyses. Conclusion AcrySof IQ Vivity intraocular lens is a highly cost-effective treatment strategy with improved vision-related quality of life outcomes for presbyopic cataract surgery patients.
Collapse
Affiliation(s)
- Chandra Bala
- personalEYES Pty Ltd, Sydney, NSW, Australia
- Correspondence: Chandra Bala, personalEYES Pty Ltd, Level 2, 33 York Street, Sydney, NSW, 2000, Australia, Tel +61-2-88337111, Fax +61-2-88337112, Email
| | | | | | | | - Amit Gupta
- Skyward Analytics Pvt Ltd, Gurgaon, India
| | | |
Collapse
|
32
|
Cummings AB, Savini G, Carones F, Kermani O, Ruiz-Mesa R. The Vivity IOL: the European Experience. CURRENT OPHTHALMOLOGY REPORTS 2022. [DOI: 10.1007/s40135-022-00283-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
33
|
Gundersen KG, Potvin R. Clinical Outcomes and Quality of Vision Associated with Bilateral Implantation of a Wavefront Shaping Presbyopia Correcting Intraocular Lens. Clin Ophthalmol 2022; 15:4723-4730. [PMID: 34983995 PMCID: PMC8699763 DOI: 10.2147/opth.s342947] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Accepted: 12/10/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose To provide normative visual acuity and quality of vision data related to bilateral implantation of a wavefront shaping presbyopia correcting intraocular lens (IOL). Patients and Methods This was a non-interventional research study of the refraction, visual acuity (VA) and quality of vision achieved after bilateral implantation of a wavefront shaping presbyopia correcting intraocular lens between 3 months and 12 months post-surgery. The manifest refraction, and uncorrected and distance corrected VA at near, intermediate and distance (40 cm, 50 cm, 66cm, 4 m) were tested. Binocular mesopic VA at 4m and uncorrected photopic low contrast (25%) VA at 4 m were also tested, the latter with and without a glare source. A patient reported outcome questionnaire was administered. Defocus curve testing with and without simulated myopia in the non-dominant eye was also tested (reported elsewhere). Results Forty subjects completed the study. There was no statistically significant difference between the uncorrected and distance corrected VA at any distance. Mean logMAR binocular VAs were (−0.07 ± 0.07) at 4 m, (0.00 ± 0.07) at 66 cm and (0.07 ± 0.11) at 40 cm. Uncorrected photopic low contrast VA was statistically significantly better without glare (0.09 ± 0.10) compared to with glare (0.44 ± 0.21, p < 0.01). Reported glare, halos and starbursts were “not at all” Or “a little” bothersome for more than 95% of subjects. Hazy vision and blurred vision were reported most often. Conclusion The Vivity IOL provided patients with good distance and intermediate vision, and functional near vision with low reported bother from glare, halos, or starbursts. ![]()
Point your SmartPhone at the code above. If you have a QR code reader the video abstract will appear. Or use: https://youtu.be/fCukWtZz0pk
Collapse
|
34
|
Newsom TH, Potvin R. Evaluation of Quality of Vision and Visual Outcomes with Bilateral Implantation of a Non-Diffractive Extended Vision Intraocular Lens with a Target of Slight Myopia in the Non-Dominant Eye. Clin Ophthalmol 2022; 16:183-190. [PMID: 35115758 PMCID: PMC8800857 DOI: 10.2147/opth.s350850] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 01/13/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
- T Hunter Newsom
- Newsom Eye & Laser Center, Sebring, FL, USA
- Correspondence: T Hunter Newsom, Email
| | | |
Collapse
|