1
|
Li ES, Vanderford EK, Xu Y, Kang PC. Rotational stability of toric intraocular lenses by lens model and haptic design: systematic review and single-arm meta-analysis. J Cataract Refract Surg 2024; 50:976-984. [PMID: 38768060 PMCID: PMC11338026 DOI: 10.1097/j.jcrs.0000000000001486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 05/01/2024] [Accepted: 05/11/2024] [Indexed: 05/22/2024]
Abstract
Rotational stability is key for optimizing postoperative visual outcomes because even a small degree of rotation of a toric intraocular lens (IOL) from its target axis can result in a significant reduction in astigmatic correction. This systematic review and meta-analysis evaluated the rotational stability of toric IOLs of different lens models and haptic designs. All published studies and clinical trials that investigate postoperative rotation of toric IOLs were searched and evaluated. Quality of studies was assessed using the Methodological Index for Nonrandomized Studies scale. A single-arm meta-analysis was performed in R4.3.1 software with subgroup analysis performed based on lens model and haptic design. 51 published studies of 4863 eyes were included in the meta-analysis. The pooled mean absolute rotation of all toric IOLs was 2.36 degrees (95% CI, 2.08-2.64). Postoperative rotation is dependent on many aspects of lens material and design. Modern commercially available toric IOLs exhibit exceptional rotational stability.
Collapse
Affiliation(s)
- Eric S. Li
- From the Yale School of Medicine, New Haven, Connecticut (Li, Vanderford); Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, Connecticut (Li, Vanderford, Kang); Yale Center for Analytical Sciences, New Haven, Connecticut (Xu)
| | - Elliott K. Vanderford
- From the Yale School of Medicine, New Haven, Connecticut (Li, Vanderford); Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, Connecticut (Li, Vanderford, Kang); Yale Center for Analytical Sciences, New Haven, Connecticut (Xu)
| | - Yunshan Xu
- From the Yale School of Medicine, New Haven, Connecticut (Li, Vanderford); Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, Connecticut (Li, Vanderford, Kang); Yale Center for Analytical Sciences, New Haven, Connecticut (Xu)
| | - Paul C. Kang
- From the Yale School of Medicine, New Haven, Connecticut (Li, Vanderford); Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, Connecticut (Li, Vanderford, Kang); Yale Center for Analytical Sciences, New Haven, Connecticut (Xu)
| |
Collapse
|
2
|
Akahoshi T. Hydrophobic Trifocal Toric Intraocular Lens Outcomes in Japanese Eyes After Cataract Surgery. Clin Ophthalmol 2024; 18:2021-2031. [PMID: 39010936 PMCID: PMC11249101 DOI: 10.2147/opth.s471846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Accepted: 07/02/2024] [Indexed: 07/17/2024] Open
Abstract
Purpose To analyze the refractive and visual outcomes following cataract surgery and implantation of a new hydrophobic trifocal toric intraocular lens (IOL) in Japanese eyes with different degrees of corneal astigmatism. Methods A total of 66 eyes from 39 patients implanted with a FineVision HP Toric IOL (Beaver-Visitec International Inc) were analyzed retrospectively. The main outcome measures considered were refraction, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), and distance-corrected intermediate visual acuity (DCIVA) at 80 and 66 cm, uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) at 40 cm. Eyes were evaluated at three months post-surgery. Results Sixty-five eyes (98.48%) were within ±0.50D of spherical equivalent, and all were within ±1.00D (mean: 0.00±0.21D). Moreover, 63 eyes (95.45%) had ≤0.50D of residual astigmatism, and all had ≤1.00D (mean: -0.08±0.23D). Similarly, 58 (87.88%) and 60 eyes (90.91%) had ≥20/20 UDVA and CDVA, respectively, with 65 (98.48%) and 66 eyes (100%) achieving ≥20/25 UDVA and CDVA, respectively. In addition, 28 (42.42%) and 23 eyes (34.85%) had ≥20/25 DCIVA at 80 and 66 cm, respectively, with 49 (74.24%) and 52 eyes (78.79%) achieving ≥20/32 DCIVA at 80 and 66 cm, respectively. Finally, 39 (59.09%) and 40 eyes (60.61%) had ≥20/20 UNVA and DCNVA, respectively, with 58 (87.88%) and 59 eyes (89.39%) achieving ≥20/25 UNVA and DCNVA, respectively. Conclusion Our study shows that implantation of the new hydrophobic FineVision HP Toric IOL results in accurate refractive outcomes, with good visual acuity at different distances, in Japanese eyes.
Collapse
Affiliation(s)
- Takayuki Akahoshi
- Cataract and Refractive Surgery Department, Nihonbashi Cataract Clinic, Tokyo, Japan
| |
Collapse
|
3
|
Daya S, Espinosa Lagana M. Visual and Refractive Outcomes of a New Hydrophobic Trifocal Toric Intraocular Lens. Clin Ophthalmol 2024; 18:997-1007. [PMID: 38584722 PMCID: PMC10999220 DOI: 10.2147/opth.s453565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 03/28/2024] [Indexed: 04/09/2024] Open
Abstract
Purpose To evaluate the visual outcomes and efficacy of astigmatism correction using a new hydrophobic trifocal toric intraocular lens (IOL). Methods This study involved 62 eyes implanted with the FineVision HP Toric IOL. The visual and refractive outcomes were assessed preoperatively and 6 weeks after the surgery. Specifically, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA) at 80 and 60 cm and uncorrected near visual acuity at (UNVA) at 40 cm were evaluated. The rotational stability of the lens was also assessed. Results Sixty-one eyes (98.39%) were within ±1.00D and 55 eyes (88.71%) were within ±0.50 D of spherical equivalent, with a mean value of 0.09±0.39 D. 51 (82.26%) and 61 (98.39%) eyes had a UDVA of ≥20/20 and ≥20/25, respectively, and for CDVA these values were as follows: 59 (95.16%) and 62 eyes (100%), respectively. The mean UDVA and CDVA were 0.01±0.06 and -0.01±0.04logMAR, respectively. Greater than or equal to unaided 20/20 vision was achieved at 40 cm in 42 (67.74%), UIVA at 60 cm in 42 (67.74%) and 50 eyes (80.65%) at 80 cm. Those achieving ≥20/25 were 56 (90.32%, 40 cm), 59 (95.16%, 60 cm), and 62 eyes (100%, 80 cm). Postoperative mean values were 0.04±0.07, 0.03±0.07, and 0.00±0.07logMAR for UCNVA, UIVA at 60 cm, and UIVA at 80 cm, respectively. The mean rotation of the IOL was 5.8 degrees. Conclusion This hydrophobic trifocal toric IOL provides good refractive outcomes with excellent visual acuity across multiple distances, providing a full range of focus.
Collapse
Affiliation(s)
- Sheraz Daya
- Centre for Sight, East Grinstead, West Sussex, UK
| | | |
Collapse
|
4
|
Bissen-Miyajima H, Ota Y, Yaguchi S, Nakamura K, Sasaki N. Clinical Results of a Trifocal Toric Intraocular Lens Using the Holladay Total Surgically Induced Astigmatism Formula for Correcting Low Corneal Astigmatism in Japanese Patients. Clin Ophthalmol 2024; 18:755-763. [PMID: 38476355 PMCID: PMC10929566 DOI: 10.2147/opth.s448427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 02/13/2024] [Indexed: 03/14/2024] Open
Abstract
Purpose To evaluate the effectiveness and safety of the AcrySof IQ PanOptix toric intraocular lens (IOL) with cylinder power of 1.0 D (TFNT20) in a Japanese population with low corneal astigmatism and compare with historical control data for nontoric IOLs. Setting Tokyo Dental College Suidobashi Hospital, Tokyo, Japan. Design Prospective, single-center study. Methods Patients ≥20 years old received TFNT20 IOL in at least 1 eye based on Alcon Toric calculator (Holladay Total surgically induced astigmatism). Effectiveness endpoints included the percentage of eyes with refractive cylinder ≤0.25 D at 30-60 days after surgery, which was compared with a historical control threshold rate of 29.2% for nontoric IOLs and refractive cylinder ≤0.50 D. Monocular uncorrected distance visual acuity (UDVA; 5 m), uncorrected intermediate visual acuity (UIVA; 60 cm), uncorrected near visual acuity (UNVA; 40 cm), and adverse events were evaluated. Results Of 41 eyes implanted with TFNT20 IOLs, 37 eyes (90%) achieved refractive cylinder ≤0.25 D at 30-60 days after surgery, demonstrating the superiority of TFNT20 compared with historical data (P<0.0001). Refractive cylinder of ≤0.50 D was achieved by 41 eyes (100%). At 30-60 days, mean ± SD monocular CDVA was -0.15 ± 0.07 logMAR, UDVA was -0.09 ± 0.09 logMAR, UIVA was -0.00 ± 0.07 logMAR, and UNVA was 0.03 ± 0.07 logMAR. Six eyes (15%) had elevated postoperative intraocular pressure, which returned to normal and was not device-related. Conclusion TFNT20 IOLs successfully reduced postoperative refractive cylinder and provided good distance, intermediate, and near uncorrected VAs in Japanese patients with low corneal astigmatism.
Collapse
Affiliation(s)
| | - Yuka Ota
- Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Tokyo, Japan
| | - Saori Yaguchi
- Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Tokyo, Japan
| | - Kunihiko Nakamura
- Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Tokyo, Japan
| | | |
Collapse
|
5
|
Markuszewski B, Wylęgała A, Szentmáry N, Langenbucher A, Markuszewska A, Wylęgała E. Comparative Analysis of the Visual, Refractive and Aberrometric Outcome with the Use of 2 Intraocular Refractive Segment Multifocal Lenses. J Clin Med 2023; 13:239. [PMID: 38202246 PMCID: PMC10779799 DOI: 10.3390/jcm13010239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/25/2023] [Accepted: 12/27/2023] [Indexed: 01/12/2024] Open
Abstract
To demonstrate the results of ray tracing higher- and lower-order aberrations in pseudophakic eyes with rotationally asymmetrical segment multifocal lenses, total high- and low-order aberrations, measured by root mean square value (RMS), refraction, uncorrected distance and uncorrected near visual acuity (UCDVA and UCNVA), and tear break-up time, were measured at scotopic size in 42 eyes of patients implanted with bifocal refractive Mplus15/Mplus30 IOL with +1.5 dpt near addition (42 eyes of patients implanted with Mplus15)/+3.0 dpt near addition (91 eyes of patients implanted with Mplus30), and 107 eyes of control group. No significant differences were noticed between the examined groups concerning UCDVA, UCNVA, and tear break-up time (p < 0.001). Coma and total high-order aberrations were significantly higher for the Mplus30 lens in comparison to the Mplus15 lens and the control group (Coma, Trefoil p < 0.001, Secondary Astigmatism p = 0.002). The spherical aberrations were significantly higher in the lower-addition lens (p = 0.016) in comparison to the control group and to the higher-addition lens group (p < 0.001). Both intraocular lens models were successful at reaching refractive aim, good distance, and near function with the lower higher-order aberrations for the low-addition lens.
Collapse
Affiliation(s)
- Bartłomiej Markuszewski
- Chair and Clinical Department of Ophthalmology, Faculty of Medical Sciences, Zabrze Medical University of Silesia, 40-760 Katowice, Poland; (A.W.)
- Wrocławskie Centrum Okulistyczne, 50-231 Wrocław, Poland
| | - Adam Wylęgała
- Chair and Clinical Department of Ophthalmology, Faculty of Medical Sciences, Zabrze Medical University of Silesia, 40-760 Katowice, Poland; (A.W.)
| | - Nóra Szentmáry
- Dr. Rofl M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, 66424 Homburg, Germany;
| | - Achim Langenbucher
- Department of Experimental Ophthalmology, Saarland University, 66424 Homburg, Germany
| | | | - Edward Wylęgała
- Chair and Clinical Department of Ophthalmology, Faculty of Medical Sciences, Zabrze Medical University of Silesia, 40-760 Katowice, Poland; (A.W.)
- Department of Ophthalmology, District Railway Hospital, 40-760 Katowice, Poland
| |
Collapse
|
6
|
Li Y, Li X, Jiang X, Wang Y, Wu T, Xia H, Li X. Comparison of dynamic visual acuity after implantation of toric bifocal or trifocal intraocular lens in age-related cataract patients: a randomized controlled trial. Front Neurosci 2023; 17:1287626. [PMID: 38178838 PMCID: PMC10765614 DOI: 10.3389/fnins.2023.1287626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Accepted: 11/20/2023] [Indexed: 01/06/2024] Open
Abstract
Purpose To investigate the dynamic visual acuity (DVA) after implantation of toric bifocal or trifocal intraocular lens in age-related cataract patients. Methods This was a prospective randomized controlled trial. Of one hundred and twenty-four patients enrolled and randomized to receive unilateral phacoemulsification and toric trifocal (939 M/MP, Carl Zeiss Meditec AG, Jena, Germany) or toric bifocal (909 M, Carl Zeiss Meditec AG, Jena, Germany) intraocular lenses (IOL) implantation, ninety-nine patients completed the follow-up and were included in final analysis. Postoperatively, uncorrected and corrected distance (UDVA and CDVA), intermediate (UIVA and DCIVA) and near (UNVA and DCNVA) static visual acuity, manifest refraction and uncorrected and corrected distance DVA (UDDVA and CDDVA) at 20, 40 and 80 degrees per second (dps) were evaluated at one week, one month and three months. Results Three months postoperatively, the UDVA were 0.13 ± 0.11 and 0.14 ± 0.13 in the toric trifocal and bifocal IOL group, respectively. Significant better UIVA (trifocal, 0.17 ± 0.13 vs. bifocal, 0.23 ± 0.13, p = 0.037) and DCIVA (trifocal, 0.16 ± 0.11 vs. bifocal, 0.20 ± 0.12, p = 0.048) were observed in patients implanting toric trifocal than bifocal IOL at three months postoperatively. Patients implanted with toric bifocal IOL obtained better CDDVA at 80 dps (0.5607 ± 0.2032) than the trifocal group (0.6573 ± 0.2450, p = 0.039) at three months. Postoperative UDDVA and CDDVA at 20, 40 and 80 dps were significantly associated with age (p < 0.05, respectively) and postoperative static visual acuity (p < 0.05, respectively). Conclusion Toric trifocal IOL provides better static intermediate visual acuity, and toric bifocal IOL implantation provides better distance dynamic visual acuity at high speed.
Collapse
Affiliation(s)
- Yuanting Li
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerves, Beijing, China
| | - Xiaodan Li
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China
- Beijing Key Laboratory of Sports Injuries, Beijing, China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, China
| | - Xiaodan Jiang
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerves, Beijing, China
| | - Yuexin Wang
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerves, Beijing, China
| | - Tingyi Wu
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerves, Beijing, China
| | - Huaqin Xia
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerves, Beijing, China
| | - Xuemin Li
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerves, Beijing, China
| |
Collapse
|
7
|
Łabuz G, Yan W, Khoramnia R, Auffarth GU. Optical-Quality Analysis and Defocus-Curve Simulations of a Novel Hydrophobic Trifocal Intraocular Lens. Clin Ophthalmol 2023; 17:3915-3923. [PMID: 38143560 PMCID: PMC10743730 DOI: 10.2147/opth.s445461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 11/20/2023] [Indexed: 12/26/2023] Open
Abstract
Purpose The optical function of a novel refractive-diffractive trifocal intraocular lens (IOL) was tested in vitro to provide preclinical metrics that predict postoperative performance and may guide patient selection. Methods Fundamental optical characteristics of a trifocal hydrophobic-acrylic IOL with a C-loop haptic configuration (AT ELANA 841P, Carl Zeiss Meditec) were assessed using a fully automated optical test device under both monochromatic and polychromatic conditions combined with increased or compensated spherical aberration (SA). The area under the modulation transfer function (MTFa) was calculated across a defocus range from +1D to -3.5D and used to simulate visual acuity (VA). A polychromatic point spread function (PSF) was employed to assess the light distribution and identify photic phenomena. Results The highest MTFa values were obtained under monochromatic conditions using an SA-neutral corneal model. Nevertheless, after introducing SA and polychromatic light, the IOL performance remained good. Simulated VA values were 0.00 logMAR for distance, 0.1 logMAR at 100 cm, and progressively improving to 0.05 logMAR at 40 cm from the intermediate point. The light-spread analysis confirmed halos around the PSF center, which is a characteristic of trifocal technology. Conclusion AT ELANA 841P demonstrated good optical performance across various distances, independently of spectral and SA conditions, resulting in good simulated VA. Although light spread resembles standard trifocal IOLs, clinical studies are essential to confirm these laboratory results.
Collapse
Affiliation(s)
- Grzegorz Łabuz
- The David J. Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, 69120, Germany
| | - Weijia Yan
- The David J. Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, 69120, Germany
| | - Ramin Khoramnia
- The David J. Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, 69120, Germany
| | - Gerd U Auffarth
- The David J. Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, 69120, Germany
| |
Collapse
|