1
|
Abane C, Macheix PS, Labattut L, Delgrandre D, Antoni M, Dordain F, Billaud A, Nourissat G, Villatte G. Glenohumeral bone lesions occurring during the first episode of shoulder dislocation do not influence function at an average of 2 years. J Shoulder Elbow Surg 2024:S1058-2746(24)00860-7. [PMID: 39631558 DOI: 10.1016/j.jse.2024.09.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 09/01/2024] [Accepted: 09/23/2024] [Indexed: 12/07/2024]
Abstract
BACKGROUND After a first shoulder dislocation, the rate of recurrence varies according to age and type of activity. The rule of bony lesions is logical but not demonstrated. We conducted a study to analyze bony lesions observed after a first episode of anterior shoulder dislocation in patients younger than 50 years of age. We assessed the functional outcomes and rate of recurrence among dislocations depending on bony lesions. METHODS We conducted a prospective, multicenter study for an average of 2 years that included patients aged 18-50 years who had experienced a first episode of anterior shoulder dislocation and who agreed to undergo computed tomography imaging within 3 weeks of trauma. A minimum follow-up duration of 1 year was required for clinical analysis. RESULTS Ninety-two patients, with a mean follow-up duration of 2 years, participated in the study. Ultimately, 13 patients were excluded: 2 were lost to follow-up, 6 underwent stabilization surgery, and 5 had a follow-up duration of less than 1 year. The mean age at inclusion was 27 years and 94% were men. Glenoid lesions were observed in 39% of patients; humeral lesions were present in 95%. Recurrence occurred in 24% of cases. There was no significant difference in functional scores between patients with and without bony lesion. There was a lower rate of residual apprehension in nonrecurrent patients compared with those who had experienced recurrence (P = .02) and a greater return to sport in the "no recurrence" subgroup (P = .02). The risk of recurrence was equivalent, regardless of the status of glenoid, humerus, or bipolar lesions. The sole predictor of recurrence after a first episode of dislocation was age younger than 20 years (P = .002). CONCLUSION Our study results provide insight into the functional outcomes and likelihood of dislocation recurrence with bony lesions after initial glenohumeral dislocation. If the first episode occurred before the age of 50 years, bony lesions were common. The overall recurrence rate was 24% with an average time of recurrence of 16 months (1-24). In our study, the presence of glenoid and/or humeral bony lesions does not seem to be a risk factor for luxation recurrence.
Collapse
Affiliation(s)
- Cynthia Abane
- Department of Orthopedics-Traumatology, CHU Dupuytren. 2, Limoges Cedex, France
| | | | - Ludovic Labattut
- Orthopedics Department, CHU F.Mitterrand Dijon-Bourgogne, Dijon, France
| | - Damien Delgrandre
- Institut de chirurgie orthopédique de Provence - Clinique Axium, Aix-en-Provence, France
| | - Maxime Antoni
- Service de chirurgie du membre supérieur, hôpital de Hautepierre 2, CHU de Strasbourg, Strasbourg, France
| | | | | | | | - Guillaume Villatte
- Service de chirurgie orthopédique et traumatologique, CHU de Clermont-Ferrand, Clermont-Ferrand, France
| |
Collapse
|
2
|
Ahmed NA, Narendran K, Ahmed NA, A P, Holebasu B, Kalawatia M, Dudeja K, Kamble P, Prasad R, Mittal G, Sangoi R. Comparison of the Glenoid Index by Computed Tomography With Magnetic Resonance Imaging. Cureus 2024; 16:e51914. [PMID: 38333443 PMCID: PMC10851955 DOI: 10.7759/cureus.51914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 01/08/2024] [Indexed: 02/10/2024] Open
Abstract
Introduction Anterior shoulder instability results in labral and osseous glenoid injuries. With a large osseous defect, there is a risk of recurrent dislocation of the joint, and therefore the patient has to undergo surgical correction. An MRI evaluation of the patient helps to assess the soft tissue injury. Currently, the volumetric three-dimensional (3D) reconstructed CT image is the standard for measuring glenoid bone loss and the glenoid index. However, it has the disadvantage of exposing the patient to radiation and additional expenses. This study aims to compare the values of the glenoid index using MRI and CT. Methodology The present study was a two-year cross-sectional study of patients with shoulder pain, trauma, and dislocation in a tertiary hospital in Karnataka. The sagittal proton density (PD) section of the glenoid and enface 3D reconstructed images of the scapula were used to calculate glenoid bone loss and the glenoid index. The baseline data were analyzed using descriptive statistics, and the Chi-square test was used to test the association of various complications with selected variables of interest. Results The glenoid index calculated in the current study using 3D volumetric CT images and MR sagittal PD images was 0.95±0.01 and 0.95±0.01, respectively. The CT and MRI glenoid bone loss was 5.41±0.65% and 5.38±0.65%, respectively. When compared, the glenoid index and bone loss calculated by MRI and CT revealed a high correlation and significance with a p-value of <0.001. Conclusions The study concluded that MRI is a reliable method for glenoid measurement. The sagittal PD sequence combined with an enface glenoid makes it possible to identify osseous defects linked to glenohumeral joint damage and dislocation. The values derived from 3D CT are identical to the glenoid index and bone loss determined using the sagittal PD sequence in MRI.
Collapse
Affiliation(s)
- Nida A Ahmed
- Trauma and Orthopaedics, Barnsley Hospital NHS foundation Trust, Barnsley, GBR
| | | | - Nishath A Ahmed
- Pediatrics, Dr. B.R. Ambedkar Medical College and Research Institute, Bangalore, IND
| | - Prashanth A
- Physiology, Mahatma Gandhi Institute of Medical Sciences, Wardha, IND
| | - B Holebasu
- Radiodiagnosis, Gadag Institute of Medical Sciences, Gadag, IND
| | | | - Kunal Dudeja
- Physiology, Maharjah's Institute of Medical Sciences, Nellimarla, IND
| | | | - Roshan Prasad
- Medicine and Surgery, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Gaurav Mittal
- Research and Development, Rotract Club Of Indian Medicos, Mumbai, IND
- Research, Students Network Organization, Mumbai, IND
- Internal Medicine, Mahatma Gandhi Institute of Medical Sciences, Wardha, IND
| | - Ravi Sangoi
- Internal Medicine, Punyashlok Ahilyadevi Holkar Government Medical College and General Hospital, Baramati, IND
| |
Collapse
|
3
|
Martins R, Quental C, Folgado J, Ângelo AC, de Campos Azevedo C. Influence of Graft Positioning during the Latarjet Procedure on Shoulder Stability and Articular Contact Pressure: Computational Analysis of the Bone Block Effect. BIOLOGY 2022; 11:biology11121783. [PMID: 36552292 PMCID: PMC9775173 DOI: 10.3390/biology11121783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/02/2022] [Accepted: 12/05/2022] [Indexed: 12/13/2022]
Abstract
The Latarjet procedure is the most popular surgical procedure to treat anterior glenohumeral (GH) instability in the presence of large anterior glenoid bone defects. Even though the placement of the bone graft has a considerable influence on its efficacy, no clear indications exist for the best graft position. The aim of this study was to investigate the influence of the medial-lateral positioning of the bone graft on the contact mechanics and GH stability due to the bone block effect. Four finite element (FE) models of a GH joint, with a 20% glenoid bone defect, treated by the Latarjet procedure were developed. The FE models differed in the medial-lateral positioning of the bone graft, ranging from a flush position to a 4.5 mm lateral position with respect to the flush position. All graft placement options were evaluated for two separate shoulder positions. Anterior GH instability was simulated by translating the humeral head in the anterior direction, under a permanent compressive force, until the peak translation force was reached. Joint stability was computed as the ratio between the shear and the compressive components of the force. The lateralization of the bone graft increased GH stability due to the bone block effect after a 3 mm lateralization with respect to the flush position. The increase in GH stability was associated with a concerning increase in peak contact pressure due to the incongruous contact between the articulating surfaces. The sensitivity of the contact pressures to the medial-lateral positioning of the bone graft suggests a trade-off between GH stability due to the bone block effect and the risk of osteoarthritis, especially considering that an accurate and consistent placement of the bone graft is difficult in vivo.
Collapse
Affiliation(s)
- Rita Martins
- IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
| | - Carlos Quental
- IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
- Correspondence:
| | - João Folgado
- IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
| | - Ana Catarina Ângelo
- Hospital CUF Tejo, Av. 24 de Julho, 1350-352 Lisboa, Portugal
- Hospital dos SAMS de Lisboa, Rua Cidade de Gabela, 1849-017 Lisboa, Portugal
| | - Clara de Campos Azevedo
- Hospital CUF Tejo, Av. 24 de Julho, 1350-352 Lisboa, Portugal
- Hospital dos SAMS de Lisboa, Rua Cidade de Gabela, 1849-017 Lisboa, Portugal
| |
Collapse
|
4
|
Aurich M, Hofmann GO, Best N. Clinical outcome and return to sports activity after surgical treatment for recurrent shoulder instability with a modified Latarjet procedure. Orthop Traumatol Surg Res 2021; 107:102977. [PMID: 34091084 DOI: 10.1016/j.otsr.2021.102977] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Revised: 10/10/2020] [Accepted: 10/29/2020] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The Latarjet procedure is an attractive surgical option for the management of chronic anterior shoulder instability. The original surgical approach involves the vertical tenotomy of the subscapularis tendon. Alternatively, the subscapularis muscle is split longitudinally and the tendon left attached at the lesser tuberosity. HYPOTHESIS The hypothesis is that the longitudinal split is of functional advantage and may lead to better functional results and earlier return to sports activities compared to the vertical tenotomy. MATERIAL AND METHODS Thirty-two patients were included in this retrospective cohort study. In 14 patients, the subscapularis tendon was vertically incised (group A), whereas in 18 patients, the subscapularis muscle was split longitudinally (group B). Patients were evaluated at 1 year (FU1) and 2 years (FU2) after the Latarjet procedure. Results at follow-up were correlated with patient-specific data and compared with the preoperative status. Primary outcomes were the functional assessment based on Western Ontario Shoulder Instability (WOSI) index and Constant Score (CS) and the assessment of the return to sports activity. Patients' demographics, duration of surgery, and the rate of recurrent dislocations were recorded as secondary variables. RESULTS All patients started their sports activities with a mean±SD of 12.41±1.24 weeks. Interestingly, the time from surgery to full recovery of sports activities was significantly longer for group A (mean±SD of 30.17±10.36 weeks) compared to group B (mean±SD of 20.71±3.67 weeks). There is a statistically significant decrease of the WOSI score from the preoperative level compared to FU1 and FU2, indicating a decrease in instability related symptoms during the entire follow up period with no statistically significant difference between group A and B. There is an increase in shoulder function during the entire follow up period based on the CS. Most interestingly, there is a statistically significant difference between group A and B at FU1, indicating a significantly better shoulder function for group B at the early follow up timepoint (FU1). At the later follow up timepoint (FU2), no difference exists in the individual items. However, a significantly better total CS remains in group B, indicating an overall improved function compared to group A. DISCUSSION/CONCLUSION The longitudinal split of subscapularis muscle is a safe approach which leads to quicker functional recovery and return to sports activity compared to the vertical tenotomy, which is a benefit especially for active individuals. It is therefore recommended as the standard surgical approach. LEVEL OF EVIDENCE III; Retrospective cohort study.
Collapse
Affiliation(s)
- Matthias Aurich
- Section of Trauma- and Reconstructive Surgery, Department of Orthopaedics, Trauma- and Reconstructive Surgery, University Hospital Halle, Ernst-Grube-Str, 40, 06120 Halle Saale, Germany; Department of Trauma- and Reconstructive Surgery, Berufsgenossenschaftliche Kliniken Bergmannstrost, Merseburger Str,. 165, 06112 Halle Saale, Germany.
| | - Gunther O Hofmann
- Department of Trauma- and Reconstructive Surgery, Berufsgenossenschaftliche Kliniken Bergmannstrost, Merseburger Str,. 165, 06112 Halle Saale, Germany; Department of Trauma-, Hand and Reconstructive Surgery, University Hospital Jena, Am Klinikum 1, 07747 Jena, Germany
| | - Norman Best
- Department of Physiotherapy, University Hospital Jena, Am Klinikum 1, 07747 Jena, Germany
| |
Collapse
|
5
|
Rosenberg SI, Padanilam SJ, Pagni BA, Tjong VK, Sheth U. A lower Instability Severity Index score threshold may better predict recurrent anterior shoulder instability after arthroscopic Bankart repair: a systematic review. J ISAKOS 2021; 6:295-301. [DOI: 10.1136/jisakos-2020-000584] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 12/11/2020] [Accepted: 01/05/2021] [Indexed: 01/27/2023]
Abstract
ImportanceThe Instability Severity Index (ISI) score was developed to evaluate a patient’s risk of recurrent shoulder instability following arthroscopic Bankart repair. While patients with an ISI score of >6 were originally recommended to undergo an open procedure (ie, Latarjet) to minimise the risk of recurrence, recent literature has called into question the utility of the ISI score.ObjectiveThe purpose of this systematic review was to evaluate the efficacy of the ISI score as a tool to predict postoperative recurrence among patients undergoing arthroscopic Bankart procedures.Evidence reviewArticles were included if study participants underwent arthroscopic Bankart repair for anterior shoulder instability and reported postoperative recurrence by ISI score at a minimum of 2 years of follow-up. Methodological study quality was assessed using the Methodological Index for Non-Randomized Studies criteria. Pearson’s χ2 test was used to compare recurrence rates among patients above and below an ISI score of 4. Sensitivity, specificity, mean ISI scores and predictive value of individual factors of the ISI score were qualitatively reviewed.FindingsFour studies concluded the ISI score was effective in predicting postoperative recurrence following arthroscopic Bankart repair; however, these studies found threshold values lower than the previously proposed score of >6 may be more predictive of recurrent instability. A pooled analysis of these studies found patients with an ISI score <4 to experience significantly lower recurrence rates when compared with patients with a score ≥4 (6.3% vs 26.0%, p<0.0001). The mean ISI score among patients who experienced recurrent instability was also significantly higher than those who did not.Conclusions and relevanceThe ISI score as constructed by Balg and Boileau may have clinical utility to help predict recurrent anterior shoulder instability following arthroscopic Bankart repair. However, this review found the threshold values published in their seminal article to be insufficient predictors of recurrent instability. Instead, a lower score threshold may provide as a better predictor of failure. The paucity of level I and II investigations limits the strength of these conclusions, suggesting a need for further large, prospective studies evaluating the predictive ability of the ISI score.Level of evidenceIV.
Collapse
|
6
|
Buckley A, Wong I. Arthroscopic Bankart Repair With Inferior to Superior Capsular Shift in Lateral Decubitus Position. Arthrosc Tech 2021; 10:e145-e150. [PMID: 33532221 PMCID: PMC7823104 DOI: 10.1016/j.eats.2020.09.023] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 09/20/2020] [Indexed: 02/03/2023] Open
Abstract
Traditional Bankart repairs for anterior labral tears of the shoulder use suture anchors to repair the anterior shoulder labrum and capsule to the glenoid. The technique described here involves releasing the anterior capsule of the glenoid and shifting it superiorly along with the labrum before anchoring. The intention of this extra step is to replicate the open technique, where the entire capsule is shifted superiorly on the glenoid.
Collapse
Affiliation(s)
- Andrew Buckley
- Dalhousie University Medical School, Halifax, Nova Scotia, Canada
| | - Ivan Wong
- Department of Surgery, Faculty of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada,Address correspondence to Dr. Ivan Wong, Department of Surgery, Faculty of Medicine, Dalhousie University, 5955 Veteran's Memorial Lane, Room 2106 VMB, Halifax, Nova Scotia, Canada, B3H 2E1.
| |
Collapse
|
7
|
Apostolakos JM, Wright-Chisem J, Gulotta LV, Taylor SA, Dines JS. Anterior glenohumeral instability: Current review with technical pearls and pitfalls of arthroscopic soft-tissue stabilization. World J Orthop 2021; 12:1-13. [PMID: 33520677 PMCID: PMC7814310 DOI: 10.5312/wjo.v12.i1.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 12/16/2020] [Accepted: 12/23/2020] [Indexed: 02/06/2023] Open
Abstract
The glenohumeral joint (GHJ) allows for a wide range of motion, but is also particularly vulnerable to episodes of instability. Anterior GHJ instability is especially frequent among young, athletic populations during contact sporting events. Many first time dislocators can be managed non-operatively with a period of immobilization and rehabilitation, however certain patient populations are at higher risk for recurrent instability and may require surgical intervention for adequate stabilization. Determination of the optimal treatment strategy should be made on a case-by-case basis while weighing both patient specific factors and injury patterns (i.e., bone loss). The purpose of this review is to describe the relevant anatomical stabilizers of the GHJ, risk factors for recurrent instability including bony lesions, indications for arthroscopic vs open surgical management, clinical history and physical examination techniques, imaging modalities, and pearls/pitfalls of arthroscopic soft-tissue stabilization for anterior glenohumeral instability.
Collapse
Affiliation(s)
- John M Apostolakos
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| | - Joshua Wright-Chisem
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| | - Lawrence V Gulotta
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| | - Samuel A Taylor
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| | - Joshua S Dines
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, NY 10021, United States
| |
Collapse
|
8
|
Bois AJ, Mayer MJ, Fening SD, Jones MH, Miniaci A. Management of bone loss in recurrent traumatic anterior shoulder instability: a survey of North American surgeons. JSES Int 2020; 4:574-583. [PMID: 32939489 PMCID: PMC7479034 DOI: 10.1016/j.jseint.2020.04.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Background Management of bone loss in recurrent traumatic anterior shoulder instability remains a topic of debate and controversy in the orthopedic community. The purpose of this study was to survey members of 4 North American orthopedic surgeon associations to assess management trends for bone loss in recurrent anterior shoulder instability. Methods An online survey was distributed to all members of the American Shoulder and Elbow Surgeons, American Orthopaedic Society for Sports Medicine, and Canadian Orthopaedic Association and to fellow members of the Arthroscopy Association of North America. The survey comprised 3 sections assessing the demographic characteristics of survey respondents, the influence of prognostic factors on surgical decision making, and the operative management of 12 clinical case scenarios of varying bone loss that may be encountered in clinical practice. Results A total of 150 survey responses were returned. The age of the patient and quantity of bone loss were consistently considered important prognostic criteria. However, little consensus was reached for critical thresholds of bone loss and how this affected the timing (ie, primary or revision surgery) and type of bony augmentation procedure to be performed once a critical threshold was reached, especially in the context of critical humeral and bipolar bone loss. Conclusions Consistent trends were found for the management of recurrent anterior shoulder instability in cases in which no bone loss existed and when isolated critical glenoid bone loss was present. However, inconsistencies were observed when isolated critical humeral bone loss and bipolar bone loss were present.
Collapse
Affiliation(s)
- Aaron J Bois
- Section of Orthopaedic Surgery, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.,Sport Medicine Centre, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | - Michelle J Mayer
- Sport Medicine Centre, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | - Stephen D Fening
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Morgan H Jones
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Anthony Miniaci
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|