1
|
Manrique-Huarte R, Álvarez de Linera-Alperi M, Pérez-Fernández N, Manrique M. Acute histological reactions in the otolith organs to inner ear drug delivery through a cochlear implant. Front Neurol 2024; 15:1363481. [PMID: 38469594 PMCID: PMC10926955 DOI: 10.3389/fneur.2024.1363481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Accepted: 01/30/2024] [Indexed: 03/13/2024] Open
Abstract
Introduction Cochlear implantation is currently regarded as a safe and minimally invasive procedure. However, cochlear implantation can have an impact on vestibular function, despite the lack of correlation between patient symptomatology and damage in vestibular tests. Thus, the present study aims to analyze the presence of hydrops and histological reactions at the level of the vestibule after cochlear implantation with dexamethasone pump delivery in Macaca fascicularis (Mf). Materials and methods A detailed histological study was conducted on a total of 11 Mf. All 11 Mf were divided into three groups: 5 Mf were implanted with an electrode array HL-14 connected to a pump delivering FITC-dextran for 24 h (Group A); 4 Mf were implanted with a CI electrode array attached to a pump for FITC-dextran delivery for 7 days (Group B); and 2 Mf were considered the control group, without any kind of cochlear device implantation (Group C). After drug deliver, the selected macaques were euthanized to collect tissue samples for histological analysis. An experienced observer, focusing on the utricle and saccule areas, conducted a blinded inner ear histology analysis. Results Surgical procedures were successfully performed in all cases. No signs of cochlear reaction to the device were observed, including neither collapse nor fibrosis. Endolymphatic sinus dilatation was observed in Mf4A and Mf3B, while cochlear hydrops was observed in Mf3A. The mean areas of the utricle and saccule exhibited some statistically significant differences, specifically, in the saccule between groups C and both groups A (p = 0.028) and B (p = 0.029); however, no significant differences were observed between groups A and B or among comparisons of the utricle. Discussion A significant concern relates to the safety of cochlear implantation with regard to vestibular preservation and hearing. New advancements in electrode arrays, such as CI devices coupled with delivery pumps, pose a challenge in maintaining minimally traumatic surgical concept-based procedures without affecting the inner ear homeostasis. The implantation of this device may cause vestibular hydrops in the saccule, indicating that the longer the time of substance release, the greater the grade of hydrops evidenced at the saccular level. Apart from this finding, the risk of histological damage to the vestibule is low.
Collapse
Affiliation(s)
- Raquel Manrique-Huarte
- Department of Otorhinolaryngology, Clínica Universidad de Navarra, University of Navarra, Pamplona, Spain
| | | | - Nicolás Pérez-Fernández
- Department of Otorhinolaryngology, Clínica Universidad de Navarra, University of Navarra, Madrid, Spain
| | - Manuel Manrique
- Department of Otorhinolaryngology, Clínica Universidad de Navarra, University of Navarra, Pamplona, Spain
| |
Collapse
|
2
|
Lorens A, Skarzynski PH, Obrycka A, Skarzynski H. Can an individual with low frequency hearing in the candidate ear benefit from a cochlear implant even if they have normal hearing in the other ear? Eur Arch Otorhinolaryngol 2023; 280:4895-4902. [PMID: 37221309 PMCID: PMC10562342 DOI: 10.1007/s00405-023-08011-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 05/08/2023] [Indexed: 05/25/2023]
Abstract
PURPOSE To determine hearing preservation and subjective benefit after cochlear implant (CI) surgery in patients with low frequency hearing in the ear to be implanted (i.e., they have partial deafness, PD) and close to normal hearing in the other. METHODS There were two study groups. The test group was made up of 12 adult patients (mean age 43.4 years; SD 13.6) with normal hearing or mild hearing loss in one ear, and with PD in the ear to be implanted. The reference group consisted of 12 adult patients (mean age 44.5 years; SD 14.1) who had PD in both ears and who underwent unilateral implantation in their worse ear. Hearing preservation was assessed 1 and 14 months after CI surgery using the Skarzynski Hearing Preservation Classification System. The APHAB questionnaire was used to evaluate the benefit from the CI. RESULTS The differences in HP% between the groups were not significant: mean hearing preservation (HP%) in the test group was 82% one month after CI surgery and 75% some 14 months after implantation; corresponding results in the reference group were 71% and 69%. However, on the APHAB background noise subscale, the benefit in the test group was significantly larger than in the reference group. CONCLUSION To a large extent it was possible to preserve low-frequency hearing in the implanted ear. This means that individuals with low frequency hearing in the implanted ear (partial deafness) and with normal hearing in the other generally received more benefits from cochlear implantation than did patients with partial deafness in both ears. We conclude that residual low frequency hearing in the ear to be implanted should not be considered a contraindication for a CI in a patient with single-sided deafness.
Collapse
Affiliation(s)
- Artur Lorens
- World Hearing Center, Institute of Physiology and Pathology of Hearing, Kajetany/Warsaw, Poland
| | - Piotr Henryk Skarzynski
- World Hearing Center, Institute of Physiology and Pathology of Hearing, Kajetany/Warsaw, Poland
- Heart Failure and Cardiac Rehabilitation Department, Medical University of Warsaw, Warsaw, Poland
- Institute of Sensory Organs, Kajetany, Poland
| | - Anita Obrycka
- World Hearing Center, Institute of Physiology and Pathology of Hearing, Kajetany/Warsaw, Poland.
| | - Henryk Skarzynski
- World Hearing Center, Institute of Physiology and Pathology of Hearing, Kajetany/Warsaw, Poland
| |
Collapse
|
3
|
Manrique-Huarte R, Garaycochea O, Troconis DP, Pérez-Fernández N, Manrique M. Histopathological reaction in the vestibule after cochlear implantation in Macaca fascicularis. J Neurol Sci 2023; 450:120672. [PMID: 37210936 DOI: 10.1016/j.jns.2023.120672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 05/02/2023] [Accepted: 05/05/2023] [Indexed: 05/23/2023]
Abstract
Cochlear implantation surgery (CI) is considered a safe procedure and is the standard treatment for the auditory rehabilitation in patients with severe-to-profound sensorineural hearing loss. Although the development of minimally traumatic surgical concepts (MTSC) have enabled the preservation of residual hearing after the implantation, there is scarce literature regarding the vestibular affection following MTCS. The aim of the study is to analyze histopathologic changes in the vestibule after CI in an animal model (Macaca fascicularis). Cochlear implantation was performed successfully in 14 ears following MTCS. They were classified in two groups upon type of electrode array used. Group A (n = 6) with a FLEX 28 electrode array and Group B (n = 8) with HL14 array. A 6-month follow-up was carried out with periodic objective auditory testing. After their sacrifice, histological processing and subsequent analysis was carried out. Intracochlear findings, vestibular presence of fibrosis, obliteration or collapse is analyzed. Saccule and utricle dimensions and neuroepithelium width is measured. Cochlear implantation was performed successfully in all 14 ears through a round window approach. Mean angle of insertion was >270° for group A and 180-270° for group B. In group A auditory deterioration was observed in Mf 1A, Mf2A and Mf5A with histopathological signs of scala tympani ossification, saccule collapse (Mf1A and Mf2A) and cochlear aqueduct obliteration (Mf5A). Besides, signs of endolymphatic sinus dilatation was seen for Mf2B and Mf5A. Regarding group B, no auditory deterioration was observed. Histopathological signs of endolymphatic sinus dilatation were seen in Mf 2B and Mf 8B. In conclusion, the risk of histological damage of the vestibular organs following minimally traumatic surgical concepts and the soft surgery principles is very low. CI surgery is a safe procedure and it can be done preserving the vestibular structures.
Collapse
Affiliation(s)
- Raquel Manrique-Huarte
- Department of Otorhinolaryngology, Clinica Universidad de Navarra, University of Navarra, Pamplona, Spain.
| | - Octavio Garaycochea
- Department of Otorhinolaryngology, Clinica Universidad de Navarra, University of Navarra, Pamplona, Spain.
| | - Daniella Parillis Troconis
- Department of Otorhinolaryngology, Clinica Universidad de Navarra, University of Navarra, Pamplona, Spain.
| | - Nicolás Pérez-Fernández
- Department of Otorhinolaryngology, Clinica Universidad de Navarra, University of Navarra, Pamplona, Spain.
| | - Manuel Manrique
- Department of Otorhinolaryngology, Clinica Universidad de Navarra, University of Navarra, Pamplona, Spain.
| |
Collapse
|
4
|
Aebischer P, Mantokoudis G, Weder S, Anschuetz L, Caversaccio M, Wimmer W. In-Vitro Study of Speed and Alignment Angle in Cochlear Implant Electrode Array Insertions. IEEE Trans Biomed Eng 2021; 69:129-137. [PMID: 34110987 DOI: 10.1109/tbme.2021.3088232] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE The insertion of the electrode array is a critical step in cochlear implantation. Herein we comprehensively investigate the impact of the alignment angle and feed-forward speed on deep insertions in artificial scala tympani models with accurate macro-anatomy and controlled frictional properties. METHODS Motorized insertions (n=1033) were performed in six scala tympani models with varying speeds and alignment angles. We evaluated reaction forces and micrographs of the insertion process and developed a mathematical model to estimate the normal force distribution along the electrode arrays. RESULTS Insertions parallel to the cochlear base significantly reduce insertion energies and lead to smoother array movement. Non-constant insertion speeds allow to reduce insertion forces for a fixed total insertion time compared to a constant feed rate. CONCLUSION In cochlear implantation, smoothness and peak forces can be reduced with alignment angles parallel to the scala tympani centerline and with non-constant feed-forward speed profiles. SIGNIFICANCE Our results may help to provide clinical guidelines and improve surgical tools for manual and automated cochlear implantation.
Collapse
|
5
|
|
6
|
Manrique-Huarte R, Calavia D, Gallego MA, Manrique M. Cochlear Implant Electrode Array From Partial to Full Insertion in Non-Human Primate Model. J Int Adv Otol 2019; 14:5-9. [PMID: 29764773 DOI: 10.5152/iao.2018.5233] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
OBJECTIVES To determine the feasibility of progressive insertion (two sequential surgeries: partial to full insertion) of an electrode array and to compare functional outcomes. MATERIAL AND METHODS 8 normal-hearing animals (Macaca fascicularis (MF)) were included. A 14 contact electrode array, which is suitably sized for the MF cochlea was partially inserted (PI) in 16 ears. After 3 months of follow-up revision surgery the electrode was advanced to a full insertion (FI) in 8 ears. Radiological examination and auditory testing was performed monthly for 6 months. In order to compare the values a two way repeated measures ANOVA was used. A p-value below 0.05 was considered as statistically significant. IBM SPSS Statistics V20 was used. RESULTS Surgical procedure was completed in all cases with no complications. Mean auditory threshold shift (ABR click tones) after 6 months follow-up is 19 dB and 27 dB for PI and FI group. For frequencies 4, 6, 8, 12, and 16 kHz in the FI group, tone burst auditory thresholds increased after the revision surgery showing no recovery thereafter. Mean threshold shift at 6 months of follow- up is 19.8 dB ranging from 2 to 36dB for PI group and 33.14dB ranging from 8 to 48dB for FI group. Statistical analysis yields no significant differences between groups. CONCLUSION It is feasible to perform a partial insertion of an electrode array and progress on a second surgical time to a full insertion (up to 270º). Hearing preservation is feasible for both procedures. Note that a minimal threshold deterioration is depicted among full insertion group, especially among high frequencies, with no statistical differences.
Collapse
Affiliation(s)
- Raquel Manrique-Huarte
- Department of Otorhinolaryngology, University of Navarra Clinic, Pamplona/Navarra, Spain
| | - Diego Calavia
- Department of Otorhinolaryngology, University of Navarra Clinic, Pamplona/Navarra, Spain
| | - Maria Antonia Gallego
- Department of Otorhinolaryngology, University of Navarra Clinic, Pamplona/Navarra, Spain
| | - Manuel Manrique
- Department of Otorhinolaryngology, University of Navarra Clinic, Pamplona/Navarra, Spain
| |
Collapse
|
7
|
|
8
|
Sierra C, Calderón M, Bárcena E, Tisaire A, Raboso E. Preservation of Residual Hearing After Cochlear Implant Surgery With Deep Insertion Electrode Arrays. Otol Neurotol 2019; 40:e373-e380. [DOI: 10.1097/mao.0000000000002170] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Wanna GB, O'Connell BP, Francis DO, Gifford RH, Hunter JB, Holder JT, Bennett ML, Rivas A, Labadie RF, Haynes DS. Predictive factors for short- and long-term hearing preservation in cochlear implantation with conventional-length electrodes. Laryngoscope 2017. [PMID: 28643327 DOI: 10.1002/lary.26714] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVES/HYPOTHESIS The aims of this study were to investigate short- and long-term rates of hearing preservation after cochlear implantation and identify factors that impact hearing preservation. STUDY DESIGN Retrospective review. METHODS Patients undergoing cochlear implantation with conventional-length electrodes and air-conduction thresholds ≤80 dB HL at 250 Hz preoperatively were included. Hearing preservation was defined as air-conduction thresholds ≤80 dB HL at 250 Hz. RESULTS The sample included 196 patients (225 implants). Overall, the rate of short-term hearing preservation was 38% (84/225), with 18% (33/188) of patients preserving hearing long term. Multivariate analysis showed better preoperative hearing was predictive of hearing preservation at short (odds ratio [OR]: 0.93, 95% confidence interval [CI]: 0.91-0.95, P < .001) and long-term follow-up (OR: 0.94, 95% CI: 0.91-0.97, P < .001). Lateral wall electrodes and mid-scala electrodes had 3.4 (95% CI: 1.4-8.6, P = .009) and 5.6-times (95% CI: 1.8-17.3, P = .003) higher odds of hearing preservation than perimodiolar arrays at short-term follow-up, respectively. Long-term data revealed better hearing preservation for lateral wall (OR: 7.6, 95% CI: 1.6-36.1, P = .01), but not mid-scala (OR: 3.1, 95% CI: 0.4-23.1, P = .28), when compared to perimodiolar electrodes. Round window/extended round window (RW/ERW) approaches were associated with higher rates of long-term hearing preservation (21%) than cochleostomy approaches (0%) (P = 0.002) on univariate analysis. CONCLUSIONS Better preoperative residual hearing, lateral wall electrodes, and RW/ERW approaches are predictive of higher rates of long-term functional hearing preservation. LEVEL OF EVIDENCE 4. Laryngoscope, 128:482-489, 2018.
Collapse
Affiliation(s)
- George B Wanna
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Brendan P O'Connell
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - David O Francis
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Rene H Gifford
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jacob B Hunter
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jourdan T Holder
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Marc L Bennett
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Alejandro Rivas
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Robert F Labadie
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - David S Haynes
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| |
Collapse
|
10
|
Eshraghi AA, Ahmed J, Krysiak E, Ila K, Ashman P, Telischi FF, Angeli S, Prentiss S, Martinez D, Valendia S. Clinical, surgical, and electrical factors impacting residual hearing in cochlear implant surgery. Acta Otolaryngol 2017; 137:384-388. [PMID: 27918225 DOI: 10.1080/00016489.2016.1256499] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
CONCLUSIONS This study recommends using soft surgical principal and round window insertion to protect residual hearing with favorable anatomical exposure. Further studies are needed to evaluate the impact of the electrical stimulation on the organ of corti and hearing. OBJECTIVE The objective of this study is to analyze various factors that impact on preservation of residual hearing post-implantation. METHODS A retrospective study was performed to analyze loss of residual hearing in a cohort of 225 patients implanted in a large academic center. Sixty-four patients met the inclusion criteria. The impact of age at implantation, gender, etiology of hearing loss, cochleostomy vs round window insertion, partial vs full insertion, and effect of initial stimulation were analyzed using appropriate statistical analysis. RESULTS The overall hearing preservation rate for all implanted patients was 64%. Loss of residual hearing was significantly more observed in cases of cochleostomy and/or non-soft surgical techniques. No correlation was observed with age at implantation, gender, side of implant, device manufacturer, and presence of pre-lingual deafness vs post-lingual, full or partial electrode insertion. In addition, there was a small but significant decrease in hearing between pre-stimulation and post-stimulation audiograms at 6000 Hz.
Collapse
Affiliation(s)
- Adrien A. Eshraghi
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Jamal Ahmed
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Eric Krysiak
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Kadri Ila
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Peter Ashman
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Fred F. Telischi
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Simon Angeli
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Sandra Prentiss
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Diane Martinez
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Sandra Valendia
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|