• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4692550)   Today's Articles (6643)
For: Zhang Y, Hu SS, Zhou JY, Sun HS, Tang Y, Zhang H, Zheng Z, Li GR, Zhu XD, Gui XM. In vivo experimental testing of the FW axial blood pump for left ventricular support in Fu Wai Hospital. ASAIO J 2009;55:28-32. [PMID: 19092667 DOI: 10.1097/MAT.0b013e31818f592f] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
Number Cited by Other Article(s)
1
Pieper IL, Radley G, Christen A, Ali S, Bodger O, Thornton CA. Ovine Leukocyte Microparticles Generated by the CentriMag Ventricular Assist Device In Vitro. Artif Organs 2018;42:E78-E89. [PMID: 29512167 DOI: 10.1111/aor.13068] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2017] [Revised: 10/06/2017] [Accepted: 10/12/2017] [Indexed: 12/13/2022]
2
Numerical and In Vitro Experimental Investigation of the Hemolytic Performance at the Off-Design Point of an Axial Ventricular Assist Pump. ASAIO J 2017;62:657-665. [PMID: 27556144 DOI: 10.1097/mat.0000000000000429] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
3
Design and numerical evaluation of an axial partial-assist blood pump for Chinese and other heart failure patients. Int J Artif Organs 2017;40:489-497. [PMID: 28777391 DOI: 10.5301/ijao.5000616] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/01/2017] [Indexed: 11/20/2022]
4
Yang XC, Zhang Y, Gui XM, Hu SS. Computational Fluid Dynamics-Based Hydraulic and Hemolytic Analyses of a Novel Left Ventricular Assist Blood Pump. Artif Organs 2011;35:948-55. [DOI: 10.1111/j.1525-1594.2011.01203.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
5
Short-term in vivo preclinical biocompatibility evaluation of FW-II axial blood pump in a sheep model. ASAIO J 2011;57:177-82. [PMID: 21478737 DOI: 10.1097/mat.0b013e3182155e70] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
6
Computational fluid dynamics analysis of thrombosis potential in left ventricular assist device drainage cannulae. ASAIO J 2010;56:157-63. [PMID: 20400890 DOI: 10.1097/mat.0b013e3181d861f1] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA